IntelliTouch i-Link Protocol Interface Adapter
Contents
1. SETCHR INQCHR Acquiring System Data IREADY Set Query Command Response Format RSPFMT lt cr gt 100 RSPFMT x lt cr gt Where x is 1 or 0 0 indicates a verbose response as shown If the RSPFMT is set to terse the response would appear as 00 x lt cr gt Command Response RSPFMT x lt cr gt 100 RSPFMT x lt cr gt Where x is 1 or 0 0 indicates a verbose response as shown If the RSPFMT is set to terse the response would appear as 00 x lt cr gt COSMSGS Query Response Set Query Change Of System Messages setting COSMSGS lt cr gt 100 COSMSGS x lt cr gt Where x is 1 or 0 0 indicates that no Change Of System messages will be sent 1 indicates that messages will be sent whenever a circuit state or temperature changes Command Response COSMSGS x lt cr gt 100 COSMSGS x lt cr gt Where x is 1 or O IntelliTouch i Link Protocol Interface Adapter Users Guide CMDCHR Set Query Command Character Value Query Response Command Response CMDCHR lt cr gt 00 CMDCHR x lt cr gt Where x is the character used to prefix all Commands By default this CMDCHR x lt cr gt 100 CMDCHR x lt cr gt Where x is the character you wish to make the CMDCHR On Power up or Reset the current value is displayed NRMCHR Set Query Normal Response Character Value Query Response Command Response NRMCHR lt cr gt 00 NRMCHR x lt cr gt
2. Control Panel COLORSWIM COLORSET COLORSYNC Send Command Command Response Colored Lights Control COLORSET lt cr gt 100 COLORSET 1 lt cr gt RSPFMT 0 100 1 lt cr gt RSPFMT 1 Note The Color Commands only operate the lights configured in the special Lights screen of COLORSWIM COLORSET COLORSYNC IntelliTouch Indoor Control Panel Start a Color Swim Sequence Set Lights to pre selected Colors Synchronize all Color Lights Special QUERY only commands POOLTMP SPATMP AIRTMP Request State Query Response Current Temperature Query Current Temperature POOLTMP lt cr gt 100 POOLTMP xx lt cr gt RSPFMT 0 100 xx lt cr gt RSPFMT 1 Where xx is the current temperature value in ASCII of the Item Note POOLTMP requires that the POOL PUMP is on and not in SPA Mode To return a valid temperature SPATMP requires that the SPA is ON IntelliTouch i Link Protocol Interface Adapter Users Guide 16 Special QUERY only commands continued OPMODE Current System Mode Query Current System Mode Request State Query OPMODE lt cr gt Response 100 XXXXXXXX lt CI gt RSPFMT 0 100 x lt cr gt RSPFMT 1 Where xxxxxx is SERVICE TIMEOUT or AUTO or in terse response 0 Auto 1 Service Timeout UNITS Current Temperature Units Query Current Temperature Units Request State Query UNITS lt cr gt Response 100 x
3. Hyper Terminal screen from the Windows XP desktop click the Start gt All Programs gt Accessories gt Communications gt Hyper Terminal 3 The Hyper Terminal new connection screen will pop up Enter any name in the connection description box Click OK The Connect To box will pop up 4 In the lower selection box labeled Connect Using select COM1 Click OK and the port settings box will pop up Bits Per Second 9600 Data Bit 8 Parity None Stop Bits 1 Flow Control None Click OK In the Hyper Terminal window click File and select and click Properties Click the Settings tab Click ASCII Setup Click to place a check mark in Send Line Ends with Line Feeds Echo Typed Characters Locally Append Line Feeds to Incoming Line Ends 10 Click OK Click OK again 11 Now in the Hyper Terminal window type RST lt enter gt OOMONODW It will take approx 10 seconds for the iLink to complete a reset process The screen will then display some start up text similar to Pentair Water i Link Protocol Interface Adapter v1 023 CMDCHR NRMCHR ERRCHR SETCHR INQCHR Acquiring System Data After 15 to 20 seconds while the device collects system information The system will display READY some other information may display if the COSMSGS is set to true You may now simply type in commands and see the responses AUX1 1 lt enter gt will switch on Auxilia
4. Power Center Before connecting cables to the IntelliTouch i Link adapter switch off the power source to the Load Power Center Connecting to the Home Automation Interface page 20 Connect the Home Automation interface RS 232 cable to the IntelliTouch i Link Protocol Interface adapter Connecting to the Indoor Control Panel page 23 Connect a cable from IntelliTouch i Link Protocol Interface adapter to the Indoor Control Panel Connecting to the Personality Board page 24 Connect a cable from 0 IntelliTouch i Link Protocol Interface adapter to the Personality board Power Load Center Start up Sequence page 1 Power up and initialize the IntelliTouch i Link adapter IntelliTouch i Link Protocol Interface Adapter Users Guide 19 Overview The IntelliTouch i Link Protocol Interface adapter allows homeowner s using Home Automation systems such as Crestron AMX Vantage Lutron and others to control IntelliTouch pool and spa functions via their Home Automation control interface including switching pumps on activating valves switching heaters or auxiliary relays on and adjusting thermostat settings Connection The IntelliTouch i Link adapter DB 9S connects to a third party home automation computer via RS 232 port and to a RS 485 communication port on the IntelliTouch Personality Board Load Center or Power Center via a Serial cable four wire This connection provides power to the IntelliTouch i Link adapter
5. connect the four conductor cable to the Personality board that connects directly to the IntelliTouch i Link adapter To connect the cable to the Personality board 1 2 ae ane Access screw CI CITI Switch the main power OFF to the Load Power Center Unlatch the front door spring latche s and open the front door of the Power Load Center Remove the screws securing the high voltage cover panel Remove the cover panel from the enclosure Loosen the two upper access screws from the Outdoor Control Panel Lower the Outdoor Control Panel down to access the Personality board Route the four conductor cable 22 AWG cable up through the low voltage raceway to the Personality board Access screw Outdoor AEE Control Panel A p p ss N aooaa i Cover panel Cover panel screw screw z Cover panel l not shown p Low voltage OO0O00O0OQO O O raceway O o o o Power Center IntelliTouch i Link Protocol Interface Adapter Users Guide 25 Start up with MobileTouch Wireless Control Panel Use the following procedure if the IntelliTouch system includes a MobileTouch wireless control panel Before the i Link adapter initializes the start up procedure the MobileTouch transceiver module cable needs be disconnected Aft
6. definable and may differ from the default characters show below The default command character set displays after a start up sequence To display these characters power down up or reset the IntelliTouch i Link adapter For the RST reset command information see page 4 IntelliTouch i Link Adapter Default Command Characters Pentair Water Pool and Spa IntelliTouch i Link Protocol InterfaceAdapter v1 0 CMDCHR NRMCHR ERRCHR SETCHR INQCHR Acquiring System Data READY The IntelliTouch system implements an addressing method upon power up For most systems the initialization is automatic The IntelliTouch i Link adapter will automatically lock on to the address within two minutes after power is applied Note f there is an IntelliTouch MobileTouch wireless control panel installed the MobileTouch Transceiver screw terminal connector needs to be removed from the Transceiver circuit board before the IntelliTouch i Link adapter initialization sequence Refer to Start up with MobileTouch Control Panel see page 25 for details IntelliTouch i Link Protocol Interface Adapter Users Guide Command Response Characters All examples given in this document assume default characters are being used Prefixes all Commands P Prefixes all successful command query responses 2 Prefixes all error messages responses is used as the SET operator 2 is used as the Query operator Command Forms Prefix L
7. i Link Protocol Interface Adapter Users Guide System Commands Command Format System commands differ in various ways Some may be used to set a state toggle a state or query a state Others may be query only or Set and Query but not Toggle SPA Spa Control Control Query Toggle Spa Request State Query SPA lt cr gt Response 100 SPA x lt cr gt RSPFMT 0 100 x lt cr gt RSPFMT 1 Where x is 1 or 0 and 1 indicates ON 0 indicates OFF Set State Command SPA x lt cr gt Where x is 1 or 0 and 1 indicates ON 0 indicates OFF Response 100 SPA x lt cr gt RSPFMT 0 100 x lt cr gt RSPFMT 1 Where x is 1 or 0 and 1 indicates ON 0 indicates OFF Toggle State Toggle SPA lt cr gt Response 100 SPA x lt cr gt RSPFMT 0 100 x lt cr gt RSPFMT 1 Where x is 1 or 0 and 1 indicates ON 0 indicates OFF PUMP Pool Control Control Query Toggle Pump pool Request State Query PUMP lt cr gt Response 100 PUMP x lt cr gt RSPFMT 0 100 x lt cr gt RSPFMT 1 Where x is 1 or 0 and 1 indicates ON 0 indicates OFF Set State Command PUMP x lt cr gt Where x is 1 or 0 and 1 indicates ON 0 indicates OFF Response 00 PUMP x lt cr gt RSPFMT 0 100 x lt cr gt RSPFMT 1 Where x is 1 or 0 and 1 indicates ON 0 indicates OFF Toggle State Command Toggle PUMP lt cr gt Response 100 PUMP x lt cr gt RSPFMT 0 100 x lt cr gt RSPFMT 1 Where x is 1 or
8. initializes the start up procedure the MobileTouch transceiver module cable needs be disconnected After the initialization process has been completed the transceiver can be reconnected To disconnect the MobileTouch transceiver screw terminal connector it 2 Switch the main power off to the IntelliTouch Load Power Center Remove the two retaining screws from the transceiver case Slide the case up to remove Remove the transceiver screw terminal connector from the transceiver circuit board Switch the main power on to the Load Power Center The i Link adapter will power up and initialize the start up procedure and assign an address to the installed equipment This process may take up to two minutes To initialize the adapter you can also use the RST reset command refer to page 4 for more information Switch the main power off to the Load Power Center Reconnect the transceiver screw terminal connector onto the transceiver board Slide the case on to the transceiver back plate Secure the transceiver case with the two retaining screws Switch the main power on to the Load Power Center The i Link adapter start up procedure is complete Case Transceiver circuit board Screw terminal Back plate Retaining screws IntelliTouch i Link Protocol Interface Adapter Users Guide 28 Glossary of Terms Feature Circuits Programmable circuits that may control relays and or valve actuators For details see the In
9. lt cr gt RSPFMT 0 100 x lt er gt RSPFMT 1 Where x is F or C MODEL IntelliTouch Model Type Query Model Type Request State Query MODEL lt cr gt Response 100 xxx lt cr gt RSPFMT 0 100 xxx lt cr gt RSPFMT 1 Where xxx is i9 3 i7 3 i5 i9 3S i5S i10 3D For more details about IntelliTouch model refer to IntelliTouch User s Guide P N 520102 PUMPLO PUMPHI Pump Status Two Speed Pumps Only Option must be set Query Pump Request State Query PUMPLO lt cr gt Response 100 PUMPLO x lt cr gt RSPFMT 0 100 x lt er gt RSPFMT 1 Where x is 1 or 0 and 1 indicates ON 0 indicates OFF PUMPLO will return True 1 anytime the pump is running PUMPHI will return True 1 only when the pump is in High Speed Example PUMPLO 1 PUMPHI 0 Pump is on in low PUMPLO 1 PUMPHI 1 Pump is on in high PUMPLO 0 PUMPHI 0 Pump is off in IntelliTouch i Link Protocol Interface Adapter Users Guide 17 Testing IntelliTouch iLink via Hyper Terminal in Windows XP The basic function of an iLink can be tested checked out using a computer and a program such as Hyper Terminal which is included in all Windows XP systems To test the iLink 1 Plug the iLink into the computer RS 232 Serial port Normally this will be COM 1 Connect the other side of the iLink cable to the IntelliTouch system 2 To access the
10. remove the base from the wall 6 Turn the base over and disconnect the four screw terminal plug from the circuit board GND BLACK D GREEN D YELLOW 15V RED Ajojn Indoor Control Panel rear view 7 Strip back the four cable conductors 1 4 in Insert the four wires into the each of the screw terminals with the existing wires Secure the wires with the four screws Make sure to match the color coding of the wires Red 15 VDC Yellow DT Green DT and GND Black Wiring details are shown above 8 Insert the screw terminal connector onto the pins on the circuit board Note that the connector is keyed for the correct orientation 9 Place the control panel base onto the wall mounted sheave and secure in place with the two retaining screws 10 Carefully snap on the control panel front cover to the base plate 11 Switch on the power source to the Power Load Center IntelliTouch i Link Protocol Interface Adapter User s Guide 24 Connecting to the Personality Board Read the following WARNING information before removing the Power Load Center enclosure high voltage cover panel A WARNING It is required that the main power into the home be switched OFF at the main circuit breaker box whenever the high voltage cover panel is removed The main power must also be switched OFF to access the Power Load Center enclosure low voltage raceway The following steps describe how to
11. 0 and 1 indicates ON 0 indicates OFF IntelliTouch i Link Protocol Interface Adapter Users Guide 7 AUXxx Auxiliary Circuit Control Control Query Toggle available Auxiliary Feature or Macro Circuits Request State Query AUXxx lt cr gt Response 100 AUXxx x lt cr gt RSPFMT 0 100 x lt cr gt RSPFMT 1 Where x is 1 or 0 and 1 indicates ON 0 indicates OFF Set State Command AUXxx X lt cr gt Where x is 1 or 0 and 1 indicates ON 0 indicates OFF Response 100 AUXxx x lt cr gt RSPFMT 0 100 x lt cr gt RSPFMT 1 Where x is 1 or 0 and 1 indicates ON 0 indicates OFF Toggle State Toggle AUXxx lt cr gt Response 100 AUXxx x lt cr gt RSPFMT 0 100 x lt cr gt RSPFMT 1 Where x is 1 or 0 and 1 indicates ON 0 indicates OFF Where xx is 1 through 8 and 11 through 50 AUX1 through AUX8 control up to eight 8 auxiliary circuits in the main power center This is also where the Spa amp Pump pool circuits reside AUX11 through AUX20 Control up to ten 10 auxiliary circuits in the second power center AUX21 through AUX30 Control up to ten 10 auxiliary circuits in the third power center AUX31 through AUX40 Control up to ten 10 auxiliary circuits in the third power center AUX41 through AUX50 Control up to ten 10 feature or macro that exist in most systems Note The adapter will not verify the existence of a given circuit For example if a command is given for AUX22 an
12. 4 Intelli tuci pool spa control system IntelliTouch i Link Protocol Interface Adapter User s Guide gt Pentair Water Pool and Spa Technical Support Sanford North Carolina 8 A M to 5 P M ET Moorpark California 8 A M to 5 P M PT Phone 800 831 7133 Fax 800 284 4151 Download PDF manuals IntelliTouch User s Guide P N 520102 at http www pentairpool com pdfs IntelliTouchUG pdf IntelliTouch i Link User s Guide P N 520450 at http www pentairpool com pdfs i LinkUG pdf 2009 Pentair Water Pool and Spa Inc All rights reserved 1620 Hawkins Ave Sanford NC 27330 e 919 566 8000 10951 West Los Angeles Ave Moorpark CA 93021 e 800 553 5000 IntelliBrite MagicStream MobileTouch IntelliTouch SAm SAL FIBERworks and Pentair Water Pool and Spa are trademarks and or registered trademarks of Pentair Water Pool and Spa Inc and or its affiliated companies in the United States and or other countries Unless noted names and brands of others that may be used in this document are not used to indicate an affiliation or endorsement between the propri etors of these names and brands and Pentair Water Pool and Spa Inc Those names and brands may be the trademarks or registered trademarks of those parties or others P N 520450 Rev B 10 09 09 Contents IntelliTouch i Link Adapter Software Commands c cccseeeeeeeeeeeeeeeeeeees 1 Start p SEQUENCE sacraro ier
13. 50 60 70 80 90 and 100 are all valid 100 xxx lt cr gt RSPFMT 1 Where xxx is 0 to indicates OFF and is a value to indicate level If ON The Value is 128 i e 30 128 30 158 Inc Dec Level Increment AUXxx lt cr gt increase dimmer level if at 100 go to 30 Decrement AUXxx lt cr gt decrease dimmer level if at 30 go to 100 Response 100 AUXxx x xx lt cr gt RSPFMT 0 Where x is 1 or 0 and 1 indicates ON 0 indicates OFF If the Dimmer is ON the xx will follow indicating the level 30 40 50 60 70 80 90 and 100 are all valid 100 xxx lt cr gt RSPFMT 1 Where xxx is 0 to indicates OFF and is a value to indicate level If ON The Value is 128 l e 30 128 30 158 IntelliTouch i Link Protocol Interface Adapter Users Guide CLEANR Request State Query Response Set State Command Response Toggle State Toggle Response Cleaner Control Control Query Toggle Cleaner CLEANR lt cr gt 100 CLEANR x lt cr gt RSPFMT 0 100 x lt cr gt RSPFMT 1 Where x is 1 or 0 and 1 indicates ON 0 indicates OFF CLEANR x lt cr gt Where x is 1 or 0 and 1 indicates ON 0 indicates OFF 100 CLEANR x lt cr gt RSPFMT 0 100 x lt cr gt RSPFMT 1 Where x is 1 or 0 and 1 indicates ON 0 indicates OFF CLEANR lt cr gt 100 CLEANR x lt cr gt RSPFMT 0 100 x lt cr gt RSPFMT 1 Where x is 1 or 0 and 1 indicate
14. For wiring and connection details see the Connection Diagram below The IntelliTouch i Link adapter operates at 9 6 kbps 9600 kilobits per second using 8 data bits 1 start bit 1 stop bit and no parity IntelliTouch i Link Adapter Location The IntelliTouch i Link adapter is for indoor use only and should be located within 25 feet of the home automation system Serial RS 232 DB 9S Connect to Home Automation Interface or PC IntelliTouch i Link Adapter RS 232 Cable Four wire 25 maximum Cable d e j Power Load Center IntelliTouch i Link Adapter Connection Diagram IntelliTouch i Link Protocol Interface Adapter User s Guide 20 Connecting to the Home Automation Interface The IntelliTouch i Link Protocol Interface adapter is identified as a RS 232 Data Communications Equipment DCE device The IntelliTouch i Link adapter DB 9S connector can use straight through wiring to connect to a DTE Data Terminal Equipment device such as a Home Automation interface or PC Laptop DB 9S Serial port connector Other DTE devices may require non straight through wiring For connection details see page 19 IntelliTouch i Link RS 232 DB 9S Signal Description The IntelliTouch i Link adapter RS 232 DB 9S connector pin outs and signal names Note Pins 1 4 and 6 connected Pins 7 and 8 connected _ DB 9S Signal Name DCE Signal Direction esa oa sanoan moa ars poguesson oum C ers eros
15. OLHT x lt cr gt Where x is 1 or 0 and 1 indicates ON 0 indicates OFF Response 100 POOLHT x lt cr gt RSPFMT 0 100 x lt cr gt RSPFMT 1 Where x is 1 or 0 and 1 indicates ON 0 indicates OFF Toggle State Toggle POOLHT lt cr gt Response 100 POOLHT x lt cr gt RSPFMT 0 100 x lt cr gt RSPFMT 1 Where x is 1 or 0 and 1 indicates ON 0 indicates OFF Note Turning POOLHT ON will enable the heater and disable solar option Turning POOLHT OFF will disable all heat sources for pool Turning SOLHT ON will select the SOLAR ONLY option of the IntelliTouch Turning SOLPREF ON will select the SOLAR PREFERRED option of the IntelliTouch The same rules apply for the Spa options IntelliTouch i Link Protocol Interface Adapter Users Guide 13 Control Heat Source Heat Method Continued Additional COSMSGS Unsolicited messages The following describes unsolicited changes in the heating source information For example the user might change the heating source selection on the Pool from Heater to Solar using the IntelliTouch Indoor Control Panel Messages will be sent to the Ilink using the formed response that would be received if the change had been initiated from the llink There are slight differences Since only one heat source selection can be active at any given time if a change is made which sets the heating selection to OFF the message will be formed as if the Ilink had instructed the Heater to go OFF ev
16. Where x is the character used to prefix all Valid non error responses from adapter By default this NRMCHR x lt cr gt 100 NRMCHR x lt cr gt Where x is the character you wish to make the NRMCHR On Power up or Reset the current value is displayed ERRCHR Query Response Command Response Set Query Error Character Value ERRCHR lt cr gt 100 ERRCHR x lt cr gt Where x is the character used to prefix all Invalid responses or error messages from adapter By default this ERRCHR x lt cr gt 00 ERRCHR x lt cr gt Where x is the character you wish to make the ERRCHR On Power up or Reset the current value is displayed SETCHR Query Response Command Response Set Query Set Character Value SETCHR lt cr gt 00 SETCHR x lt cr gt Where x is the character used as the operator in all Set commands By default this SETCHR x lt cr gt 100 SETCHR x lt cr gt Where x is the character you wish to make the SETCHR On Power up or Reset the current value is displayed INQCHR Query Response Command Response Set Query Inquire Character Value INQCHR lt cr gt 100 INQCHR x lt cr gt Where x is the character used as the operator in all Query commands By default this INQCHR x lt cr gt 100 INQCHR x lt cr gt Where x is the character you wish to make the INQCHR On Power up or Reset the current value is displayed IntelliTouch
17. abel Operator Value lt cr gt Example SPA 1 lt cr gt Turn SPA ON Where the Prefix is factory default may be changed with CMDCHR Where the Label or Command is SPA Where the Operator is i e set this circuit to value Where the Value is 1 i e ON The Prefix and the Operator must be the correct symbols The Label must be exact spelling from the command list Though it may be Upper or lower case or any combination The Value must be one of the valid options and valid for that command ON values are 1 ON Y or YES T or TRUE OFF values are 0 OFF N or NO F or FALSE A single space may or may not be used between the Label and Operator the Operator and Value the Value and lt cr gt No space s is allowed between the Prefix and the Label Examples Prefix Label Operator Value lt cr gt valid Prefix Label Operator Value lt cr gt valid Prefix Label Operator Value lt cr gt valid Prefix Label Operator Value lt cr gt invalid IntelliTouch i Link Protocol Interface Adapter Users Guide 3 Query Command Forms Prefix Label Operator lt cr gt Example SPA lt cr gt Query SPA State Where the Prefix is factory default may be changed with CMDCHR Where the Label or Command is SPA Where the Operator is i e Query The Prefix and the Operator must
18. be the correct symbols The Label must be exact spelling from the command list using upper or lower case or any combination A single space may or may not be used between the Label and Operator and the Operator and lt cr gt No space s is allowed between the Prefix and the Label Error Messages Responses Form Prefix Error Number Message lt cr gt RSPFMT 0 Prefix Error Number lt cr gt RSPFMT 1 Example 02 BAD COMMAND FORM Where the Prefix is factory default may be changed with ERRCHR Where the Error Number 02 Where the Message is BAD COMMAND FORM If RSPFMT is terse RSPFMT 1 only the Prefix and Error Number are returned Error Messages 01 INVALID COMMAND 02 BAD COMMAND FORM 11 485 SET GET VALUE TIME OUT 22 AUX OFF DIMMER CTL IGNORED 23 OPTION SWITCH NOT SET 88 INTERFACE BUSY 98 UNKNOWN ERROR CONDITION 99 UNKNOWN COMMAND VALUE IntelliTouch i Link Protocol Interface Adapter Users Guide Adapter Commands Command Format Adapter commands are used to set required or preferred actions and responses for a given application Such as the RSPFMT command that is used to determine the type of response expected by the computer or home automation system RST Command Response RSPFMT Query Response Reset Adapter RST lt cr gt Pentair Water i Link Protocol Interface Adapter v1 0 CMDCHR NRMCHR ERRCHR
19. d no such circuit exists in the system no indication is given The state and status will appear normal It is the installer operators responsibility to insure circuits exist AUXxx Dimmer Circuit Control AUXxx AUXxx Control Query Toggle available Dimmer Request State Query AUXxx lt cr gt Response 100 AUXxx x xx lt cr gt RSPFMT 0 Where x is 1 or 0 and 1 indicates ON 0 indicates OFF If the Dimmer is ON the xx will follow indicating the level 30 40 50 60 70 80 90 and 100 are all valid 100 xxx lt cr gt RSPFMT 1 Where xxx is 0 to indicates OFF and is a value to indicate level If ON The Value is 128 i e 30 128 30 158 IntelliTouch i Link Protocol Interface Adapter Users Guide Set State Command AUXxx x lt cr gt Where x is 1 or 0 and 1 indicates ON 0 indicates OFF Response 100 AUXxx x xx lt cr gt RSPFMT 0 Where x is 1 or 0 and 1 indicates ON 0 indicates OFF If the Dimmer is ON the xx will follow indicating the level 30 40 50 60 70 80 90 and 100 are all valid 100 xxx lt cr gt RSPFMT 1 Where xxx is 0 to indicates OFF and is a value to indicate level If ON The Value is 128 l e 30 128 30 158 Toggle State Toggle AUXxx lt cr gt Response 100 AUXxx x xx lt cr gt RSPFMT 0 Where x is 1 or 0 and 1 indicates ON 0 indicates OFF If the Dimmer is ON the xx will follow indicating the level 30 40
20. eeeeeeeeeseeeeeeeeseaeeeeeeeeaees 7 CLEANR Cleaner Control sic isctes sortie tintin ees sisside svisa ireas nete 9 SPILLWAY WFALL Waterfall Spillway Control c cceccceeteeeeeeeeeeeeeeeeeeeees 10 Control Heat Source Heat Method eee eeceeeeeeeeeeeeceeeeeeeeeeeeeneeseaeeneeeenaees 12 Special COMMAND Only COMMAMNAS ccsecceeeeeeeeeeeeeeeeeeeeneeeeeeeeeeeeeneneenneee 14 IntelliBrite LED Lights and MagicStream Lamiinars c eeeeeeeees 14 Sam Sal PG2000 Fiber Optic Lights c ccecscceesseeeseeeeeeeneeeeeeeesseeeess 14 ALLLIGHTS All Lights Control ieii iin anssen 15 COLORSWIM Colored Lights Control ccceeeceeeeeeeeeeeeeeeeeeeeeeneeteeeenees 15 Special QUERY only COMMAMAS ecseeeeeeeeeeeeeseeeeeeeeeeeeeeeenenenseeeneeeeseeeeneeas 15 POOLTMP Current Temperature cccccccscescseeseteeseteesetecsetecsenecsenecsenecsens 15 OPMODE Current System Mode ccecceeceeeeeeseeeeeeeeeeeeeeeeseeeeeeeeeeneeeeeeeeaes 16 UNITS Current Temperature UNnitS 2 0 ee ceceeeeeeeeeeeeeeeeeseeeeeeeseeeenaeeeeneee 16 MODEL IntelliTouch Model Type cceecceesceeeeeteeeseeeseaeeseeeeaeeeeeseaeeeeeees 16 PUMPLO PUMPHI Pump Status Two speed Pumps Only eeeee 16 Testing IntelliTouch iLink via Hyper Terminal in Windows XP 17 IntelliTouch i Link Protocol Interface Adapter Installation csesseese 18 Summary Informatio Maanen ae We eau apelin 18 COVE IVIOW ou cae San cc
21. en if the change was from for example Solar to No Heat The unsolicited messages included in Ilink firmware version 1 021 are as follow Pool Heating 00 POOLHT 0 Pool Heating Selection has changed to OFF No Heat 00 POOLHT 1 Pool Heating Selection has changed to ON Heater 100 SOLHT 1 Pool Heating Selection has changed to Solar Only 00 SOLPREF 1 Pool Heating Selection has changed to Solar Preferred Spa Heating 00 SPAHT 0 Spa Heating Selection has changed to OFF No Heat 100 SPAHT 1 Spa Heating Selection has changed to ON Heater 00 SPASOLHT 1Spa Heating Selection has changed to Solar Only 00 SPASOLPREF 1SpaHeating Selection has changed to Solar Preferred The Single Body Single Equipment Units 19 3S amp 15 3S aka 15S use a slightly different labeling scheme to maintain minimum compatibility with an older interface Low Temperature Selection Heating 00 POOLHT 0 Heating Selection has changed to OFF No Heat 00 POOLHT 1 Heating Selection has changed to ON Heater 100 SOLHT 1 Heating Selection has changed to Solar Only 00 SOLPREF 1Heating Selection has changed to Solar Preferred High Temperature Selection Heating 00 POOLHT2 0 Heating Selection has changed to OFF No Heat 00 POOLHT2 1 Heating Selection has changed to ON Heater 00 SPASOLHT 1Heating Selection has changed to Solar Only 100 SPASOLPREF 1Heating Selection has changed to Solar Preferred IntelliTouch i Link Prot
22. er the initialization process has been completed the transceiver can be reconnected To disconnect the MobileTouch transceiver screw terminal connector 1 2 Switch the main power off to the IntelliTouch Load Power Center Remove the two retaining screws from the transceiver case Slide the case up to remove Remove the transceiver screw terminal connector from the transceiver circuit board Switch the main power on to the Load Power Center The i Link adapter will power up and initialize the start up procedure and assign an address to the installed equipment This process may take up to two minutes To initialize the adapter you can also use the RST reset command refer to page 4 for more information Switch the main power off to the Load Power Center Reconnect the transceiver screw terminal connector onto the transceiver board Slide the case on to the transceiver back plate Secure the transceiver case with the two retaining screws Switch the main power on to the Load Power Center The i Link adapter start up procedure is complete Strip back the cable conductors in Insert the four wires into the screw terminals on either COM PORTS J7 and J8 plugs located on the left side of the Personality board Secure the wires with the four screws Make sure to match the color coding of the wires Red 15 V Yellow DT Green DT and GND Black Wiring details are shown below Note Multiple wires may be inserted i
23. es era a E a a E n died 1 General Command Response Formats csccseceseeeeeseeenseeeeeeeseeeeeeeeeeennees 2 Command Response Characters ccccececeseeeeeeeeeeneeeeeeeeneeseeeeeeesieeeeneeennees 2 Query Command Forms i iseincins ner naki eyen N aE NES 3 Error Messages Responses Form ceccseeeeeeeeeeeeeeneeeeeeeeaeeseeeeeeeeeneeeeaeeeeenea 3 Adapter Commands Command Format s ssssssunsunnnrennrnnnnnnnnnnannnnnnnnnnnnnnnnnnnn 4 RST Reset Adapter Pscs ieie esie eee ie Na A A EEEE TNS RSPFMT Set Query Command Response Format COSMSGS Set Query Change Of System Messages setting 4 CMDCHR Set Query Command Character Value cccssseeesteeeeseeeeees 5 NRMCHR Set Query Normal Response Character Value cceeeeeeeeeees 5 ERRCHR Set Query Error Character Value c ceecceeeeeeeeeeeeeeeeeeeneeeeneeenes 5 SETCHR Set Query Set Character Value eceecceeeeeeeeeeeneeseeeeeretetenteeenaees 5 INQCHR Set Query Inquire Character Value ceeceeeceeeeeseeeeeeeeeeeeeeeeeeneees 5 System Commands Command Format scccceceecsseeseeeeseeneeeeeseeeseeeeseeeeeeenes 6 SPA Spa Control Control Query Toggle Spa eseeeceeeeeeeeeseeeeeereteeeeeneetenes 6 PUMP Pool Control Control Query Toggle Pump Pool ccccceeeeeeeee 6 UXxx Auxiliary Circuit Control ccc eeeeeceeseeeeeeeeeeeeeeeeeeeeeeeeseeeeeneetiaeeeeneeentes T AUXxx Dimmer Circuit Control 2 0 eeceeeeceeeeeeeeeeeeene
24. h dete a E e a a E EEEE EE E E iS 19 COMNMECHION irrena o E e araa a ETE NAE 19 IntelliTouch i Link Adapter Location asesssseseseneerenernesrrarrnnnrrnnerrnnsennesnnnes 19 Connecting to the Home Automation Interface ceceeeseeeeeeeeeeeteeeneetens 20 IntelliTouch i Link RS 232 DB 9S Signal Description 10 ceeeeeeeeee 20 Connecting to the i Link Adapter ecceeceeeeeeseeeeneeeeeeeeeeeeaeeeeeeeeeeteeeeeaees 21 Connecting to the Indoor Control Panel cecceeeeeeeseeeseeeeteeeeeeseeeeeeeennees 22 Connecting to the Personality Board sceeseeseeeeeeeeeeeeeeeeeeeeseeeeneeenneenaes 23 Start up with MobileTouch Wireless Control Panel cceecceeeeeeeeeeeees 25 Glossary Of Tern S iicacsiicceccsccecascecnceectcncnnceccensectcccussnteescesaccenscessnsceancesauexteazcaues 26 IntelliTouch i Link Protocol Interface Adapter Users Guide 1 Overview This manual provides IntelliTouch i Link software control commands for IntelliTouch system equipment such as lights pumps etc For additional information about the IntelliTouch control system refer to the IntelliTouch User s Guide P N 520102 Intellitouch i Link Adapter Software Commands Start up Sequence Each time the IntelliTouch i Link adapter is powered up a start up initialization sequence is sent to the Home Automation system via the RS 232 port and the current command characters display These special command characters are also user
25. m oum L mananam wa IntelliTouch i Link Protocol Interface Adapter Users Guide 21 Connect to the IntelliTouch i Link Adapter The IntelliTouch i Link adapter can be connected to either the IntelliTouch Indoor Control Panel or directly to the IntelliTouch Load or Power Center at the equipment pad The four wire cable can also be connected at any point along the communication cable that connects the Indoor Control Panel to the Personality board Before connecting the cable to the i Link adapter first determine the length of cable required for the connection For connection details see Connection Diagram page 19 To connect the four conductor cable to the IntelliTouch i Link adapter see Figure 1 1 Run a four conductor cable 22 AWG UL approved from either the Indoor Control Panel or the Power Load Center location to the IntelliTouch i Link adapter Using a small flat blade screw driver insert the blade into one of the side notches and pry apart the case not completely Remove the screwdriver blade from the notch and insert the blade into the other notch and pry apart to separate the two halves of the adapter case Remove the screw terminal connector from the circuit board Please observe Electrostatic Sensitive Device ESD handling precautions when removing the connector Strip back the four cable conductors inch Insert the four wires into the screw terminals Secure the wires with the four screws Make sure t
26. mode IB_ AMERICAN Set ALL IntelliBrite Units to AMERICAN mode IB_ SUNSET Set ALL IntelliBrite Units to SUNSET mode IB_ROYALTY Set ALL IntelliBrite Units to ROYALTY mode IB_ BLUE Set ALL IntelliBrite Units to BLUE IB_GREEN Set ALL IntelliBrite Units to GREEN IB_RED Set ALL IntelliBrite Units to RED IB_WHITE Set ALL IntelliBrite Units to WHITE IB_MAGENTA Set ALL IntelliBrite Units to MAGENTA IB_HOLD Command ALL IntelliBrite Units to Hold Stop Freeze IB_RECALL Command ALL IntelliBrite Units to Recall last setting The following commands only support MagicStream laminars MS_THUMPER Toggle ALL MagicStream Thumpers ON or OFF MS_HOLD Command ALL MagicStream Units to Hold Stop Freeze MS_RESET Reset ALL MagicStream units MS_MODE Toggle Mode on ALL MagicStream Units Random Party Sync MS_SYNC Set ALL MagicStream units to SYNC Mode MS_RANDOM Set ALL MagicStream units to RANDOM Mode MS_PARTY Set ALL MagicStream units to PARTY Mode IntelliTouch i Link Protocol Interface Adapter Users Guide 15 Special COMMAND only commands for lights ALLLIGHTS All Lights Control Set State Command Response Control All Lights ALLLIGHTS x lt cr gt Where x is 1 or 0 and 1 indicates ON 0 indicates OFF 100 ALLLIGHTS x lt cr gt RSPFMT 0 100 x lt cr gt RSPFMT 1 Where x is 1 or 0 and 1 indicates ON 0 indicates OFF Note ALLIGHTS only operate the lights configured in the special Lights screen of IntelliTouch Indoor
27. nto a single screw terminal caution Do NOT short GND or 15VDC connections Red or Black to data lines Green or Yellow The Personality board may be permanently damaged Do NOT reverse GND or 15V or system will not operate 10 11 Install the cover panel and secure with the two retaining screws Close the hinged Outdoor Control Panel and secure with the two access screws Close the front door of the Power Load Center Fasten the spring latche s Switch on the power source to the Power Load Center IntelliTouch i Link Protocol Interface Adapter Users Guide Left side of Personality Board 26 VALVE ACTUATORS ey Lark aA oe Loser se HEATER le r i7 AND i9 one COM PORTS USE EITHER OR BOTH INDOOR CONTROL AND OR RF TRANSCEIVER AND OR i 10 SPA SIDE REM Ld 000000000000 ooo0oo0oo0o00 O e 2 Power Center IntelliTouch i Link Protocol Interface Adapter Users Guide 27 Start up with MobileTouch Wireless Control Panel Use the following procedure if the IntelliTouch system includes a MobileTouch wireless control panel Before the i Link adapter
28. o match the color coding of the wires with the pin colors indicated on the circuit board RED 15 YEL DT GRN DT and BLK Ground Refer to the wiring table below Insert the screw terminal connector onto the pins on the circuit board Note that the connector is keyed for the correct orientation Snap the two halves of the adapter case together Make sure the wire exits out of the wire exit hole Proceed with either of the following cable connections e Connecting to the Indoor Control Panel page 22 e Connecting to the Personality board page 24 IntelliTouch i Link Protocol Interface Adapter Users Guide 22 Screw Terminal Connector Connect to Indoor Control Panel or Personality Board Figure 1 IntelliTouch i Link Protocol Interface Adapter Users Guide 23 Connecting to the Indoor Control Panel To connect the i Link communication cable to the Indoor Control Panel Switch the main power OFF to the Load Power Center 2 Route the four conductor cable from the IntelliTouch i Link adapter to the location of the Indoor Control Panel 3 Remove the control panel front cover From the front of the control panel insert the tip of a small flat blade screwdriver into the notch on the top edge of the control panel cover and gently pry the cover off from the control panel base 4 Remove the two control panel base retaining screws 5 Carefully lift the control panel base up from the wall mounted sheave and
29. ocol Interface Adapter Users Guide 14 Special COMMAND Only commands for IntelliBrite LED Lights and MagicStream Laminars The following lighting commands support IntelliBrite LED lights and MagicStream laminars For more information also see COLORSYNC COLORSET and COLORSWIM commands see page 15 The following commands for the IntelliBrite LED light and the MagicStream Laminar are as follows Note The following commands require i Link version 1 021 or higher The MagicStream laminar commands for Random Sync and Party require IntelliTouch outdoor control panel version 1 132 or higher COLORSWIM Colored Lights Control COLORSET COLORSYNC Send Command Command COLORSET lt cr gt Response 100 COLORSET 1 lt cr gt RSPFMT 0 100 1 lt cr gt RSPFMT 1 Note The above color commands only operate lights configured in the special IntelliTouch Lights screen Sam Sal PG2000 Fiber Optic lights and IntelliBrite LED lights The following commands support the Sam Sal PG2000 Fiber Optic Unit and IntelliBrite LED light These commands do not support the MagicStream laminar COLORSWIM Start a Color Swim Sequence COLORSET Set Lights to pre selected Colors COLORSYNC Synchronize All Color Lights The following commands only support the IntelliBrite LED lights IB_PARTY Set ALL IntelliBrite Units to PARTY mode IB_ ROMANCE Set ALL IntelliBrite Units to ROMANCE mode IB_CARIBBEAN Set ALL IntelliBrite Units to CARIBBEAN
30. ption of the circuit breaker base Screw Terminal Removable connector that may attach to circuit board with multiple sockets anywhere from 2 to 12 to receive wires from controllers and sensors wires held by screw terminals IntelliTouch i Link Protocol Interface Adapter Users Guide Pentair Water Pool and Spa P N 520450 Rev B
31. ry 1 and create a response similar to 100 AUX1 1 AUX1 O lt enter gt will switch off Auxiliary 1 and create a response similar to 100 AUX1 0 All of the commands and queries listed in the iLink manual may be operated on the computer via Hyper Terminal This allows testing of the various commands and assists in troubleshooting If the 201 INVALID COMMAND message is received the command has been entered incorrectly IntelliTouch i Link Protocol Interface Adapter Users Guide 18 IntelliTouch i Link Protocol Interface Adapter Installation Installation This section provides installation information for the IntelliTouch i Link Protocol Interface Adapter For additional information about the IntelliTouch control system refer to the IntelliTouch User s Guide P N 520102 The following items are included in the IntelliTouch i Link Protocol Interface Adapter kit e IntelliTouch i Link Protocol Interface adapter with screw terminal connector installed e IntelliTouch i Link Protocol Interface Adapter User s Guide this manual Required Tools e Small flat blade screwdriver for opening the IntelliTouch i Link adapter case e Wire Stripping Tool for stripping cable wires Summary Information For connection options refer to the IntelliTouch i Link Adapter Connection Diagram page 19 The recommended connection steps for the IntelliTouch i Link adapter are Switch power off to the IntelliTouch Load
32. s ON 0 indicates OFF Note The CLEANR commands assume a circuit has been configured as a cleaner If there are no circuits configured the response will be an error message 23 OPTION SWITCH NOT SET IntelliTouch i Link Protocol Interface Adapter Users Guide SPILLWAY 10 WFALL Waterfall Spillway Control Control Query Toggle Pump pool Request State Query Response Set State Command Response Toggle State Toggle Response WFALL lt cr gt 100 WFALL x lt cr gt RSPFMT 0 100 x lt cr gt RSPFMT 1 Where x is 1 or 0 and 1 indicates ON 0 indicates OFF WFALL x lt cr gt Where x is 1 or 0 and 1 indicates ON 0 indicates OFF 100 WFALL x lt cr gt RSPFMT 0 100 x lt cr gt RSPFMT 1 Where x is 1 or 0 and 1 indicates ON 0 indicates OFF WFALL lt cr gt 100 WFALL x lt cr gt RSPFMT 0 100 x lt cr gt RSPFMT 1 Where x is 1 or 0 and 1 indicates ON 0 indicates OFF Note The WFALL commands assume a circuit has been configured as a Waterfall If there are circuits configured the response will be an error message 23 OPTION SWITCH NOT SET Note The keyword WFALL and SPILLWAY are interchangeable IntelliTouch i Link Protocol Interface Adapter Users Guide 11 POOLSP Temperature Set Point Control POOLSP2 Control Query Temperature Set Point SPASP POOLSP is used for the example Request State Query POOLSP lt cr gt Response 100 POOLSP xx l
33. t cr gt RSPFMT 0 100 xx lt cr gt RSPFMT 1 Where xx is the current temperature value in ASCII of the pools desired heating set point Set Value Command POOLSP xx lt cr gt Where xx is the desired temperature Response 100 POOLSP xx lt cr gt RSPFMT 0 100 xx lt cr gt RSPFMT 1 Where xx is the current temperature value in ASCII of the Pools desired heating set point Note POOLSP2 is valid only on Models i9 3S and i5S It is used to set the High Temperature It is equivalent To SPASP POOLSP Inc Dec temperature Set Point POOLSP POOLSP is used for the example SPASP SPASP Inc Dec Value Command POOLSP lt cr gt Response 100 POOLSP xx lt cr gt RSPFMT 0 100 xx lt cr gt RSPFMT 1 Where xx is the current temperature value in ASCII of the Pools desired heating set point IntelliTouch i Link Protocol Interface Adapter Users Guide 12 Control Heat Source Heat Method POOLHT Enable Disable Pool Heater POOLHT2 Enable Disable High Pool Heater SPAHT Enable Disable Spa Heater SOLHT Enable Disable Pool Solar SPASOLHT Enable Disable Spa Solar SOLPREF Enable Disable Pool Solar Preferred SPASOLPREF Enable Disable Spa Solar Preferred Note POOLHT is used in this example Request State Query POOLHT lt cr gt Response 100 POOLHT x lt cr gt RSPFMT 0 100 x lt cr gt RSPFMT 1 Where x is 1 or 0 and 1 indicates ON 0 indicates OFF Set State Command PO
34. telliTouch Systems User s Guide P N 520102 High Voltage Compartment Large lower right compartment of Load Center for all high voltage wiring including circuit breakers relays and GFCI Indoor Control Panel A 14 button remote controller with LCD liquid crystal display wired to the Personality board in the Power Load Center The indoor control panel can be wall mounted inside a house to control IntelliTouch control system IntelliBrite LED Light Underwater pool or spa LED light emitting diode color light Load Center Metal enclosure with power relays transformer and circuit breakers The Load Center is Installed prior to Personality Kit installation Used for distributing power for controlling IntelliTouch Systems Also known as the sub panel Low Voltage Compartment Top compartment of Load Center for all low voltage wiring Low Voltage Raceway Vertical space in the left side of Power Load Center for low voltage cabling MagicStream Laminar Water effect designed to provide a clear turbulence free stream of water that can be lit with a fiber optic cable or an LED light engine Outdoor Control Panel Control panel with flexible hinge installed in upper portion of Power Load Center to control IntelliTouch systems Personality Board The circuit board mounted on top of the Outdoor Control Panel motherboard The Personality board defines the system capabilities Power Center Same as Load Center with the exce