1. for inspection Again please save the carton and all packing materials If a fixture must be returned to the factory it is important that the fixture be returned in the original factory box and packing Powering Up All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel is used solely for a 0 to 100 switch AC Voltage Switch Not all fixtures have a voltage select switch so please verify that the fixture you receive is suitable for your local power supply See the label on the fixture or refer to the fixture s specifications chart for more information A fixture s listed current rating is its average current draw under normal conditions Check the fixture or device carefully to make sure that if a voltage selection switch exists that it is set to the correct line voltage you will use Warning Verify that the voltage select switch on your unit matches the line voltage applied Damage to your fixture may result if the line voltage applied does not match the voltage indicated on the voltage selector switch All fixtures must be connected to circuits with a suitable Ground Earthing wdmlighting com 4106 Harry Hines Bivd Dallas Texas 75219 800 893 9787 ColorFlat 9 RGB WEI educate create collaborate SAFETY INSTRUCTIONS Please read these instructions carefully They include important information
2. lt DOWNS keys select the color you wish to display by varying Red Green Blue intensity between 0 and 255 then hit lt ENTER gt to confirm each color choice 4 Select Color preset mode as instructed above then select CoL 7 then lt ENTER gt to confirm To Show the Fixture Running Hours 1 Select FhrS from the control panel then hit lt ENTER gt to confirm wdmilighting com 4106 Harry Hines Blvd Dallas Texas 75219 800 893 9787 ColorFlat 9 RGB WEI educate create collaborate Troubleshooting Fixture Auto Shut Off No Light Output Slow Movement No Response to Audio Fixture Not Responding Responding Erratically Intermittent Lamp Remote Doesn t Work Fixture Moving On Its Own Check the fan in the fixture If it is stopped or moving slower than normal the unit may have shut itself off due to high heat This is to protect the fixture from overheating Clear the fan of obstructions or return the unit for service Check optical system and clean excess dust grime Also ensure that the 220V 110V switch is in the correct position if applicable Check to ensure fixture is operating under correct mode IE sound active auto DMX Etc if applicable Contact service for more information Chase Speed Check to ensure proper setup of speed adjustment Too Fast Slow Check fuse AC cord and circuit for malfunction Blown Fuse Check AC cord and circuit for damage verify that moving p
3. ColorFlat 9 RGB Wel educate create collaborate wdmlighting com 4106 Harry Hines Blvd Dallas Texas 75219 800 893 9787 ColorFlat 9 RGB VAC educate create collaborate TABLE OF CONTENTS The ColorFlat 9 rgb LED PAR Can 1 Ww 1 Getting Started What s In The Box Getting It Out Of The Box Powering Up Getting A Hold Of Us Safety Instructions 2 Meet The ColorFlat 9 rgb LED PAR Can Features DMX Quick Reference 4 and 6 Channel Modes The ColorFlat 9 rgb Aun YW Awww w 3 Setup Fuse Replacement Connecting ColorFlat 9 rgb LED PAR Cans Data DMX Cables NNN N 4 Operating Adjustments DMX Mode amp DMX Mode Selection Master Slave Mode Sound Active Mode Custom Color Display Fixture running hour display Troubleshooting 5 Appendix 10 Maintenance 10 Returns 10 Shipping Issues 10 Tech Specs 11 WV o Q wdmlighting com 4106 Harry Hines Bivd Dallas Texas 75219 800 893 9787 ColorFlat 9 RGB WEI educate create collaborate 1 GETTING STARTED What s In The Box e 1 x ColorFlat 9 rgb LED PAR Fixture e 1x IEC Power Cord e User Manual Getting It Out Of The Box Now that you ve got The ColorFlat 9 rgb you should carefully unpack the box and check the contents to ensure that all parts are present and in good condition If anything looks as if it has been dam aged in transit notify the shipper immediately and keep the packing material
4. about the installation usage and maintenance of this product e Please keep this User Guide for future use If you sell the unit to someone else be sure that they also receive this User Guide e ALWAYS make sure that you are connecting to the proper voltage and that the line voltage you are connecting to is not higher than that stated on the de cal or rear panel of the fixture e This product is intended for indoor use only e To prevent risk of fire or shock do not expose fixture to rain or moisture e Make sure there are no flammable materials close to the unit while operating e The unit must be installed in a location with adequate ventilation at least 20in 50cm from adjacent surfaces Be sure that no ventilation slots are blocked e ALWAYS disconnect from the power source before servicing or replacing fuse and be sure to replace with same fuse size and type e ALWAYS secure fixture using a safety chain NEVER carry the fixture by its cord Use its carrying handles e DO NOT operate at ambient temperatures higher than 104 F 40 C e In the event of a serious operating problem stop using the unit immediately NEVER try to repair the unit by yourself Repairs carried out by unskilled people can lead to damage or malfunction Please contact the nearest authorized technical assistance center Always use the same type spare parts e NEVER connect the device to a dimmer pack e Make sure the power cord is never crimped or
5. ard DMX cables to daisy chain your units together via the DMX con nector on the rear of the units It may be necessary to use a terminator at the last fixture For more information about terminators see page 8 2 Choose a unit to function as the Master Select MAST The master unit must be the first unit Finally chain the units together using DMX cable Master SLNd then NASt_ to confirm 3 Select slave function by using the lt UP gt lt DOWN gt keys to reach SLAV in the Master Auto menu on the slave units and they will react in the same as the Master Slave SLNd then SLAu to confirm 4 On the master fixture use the lt UP gt lt DOWN gt keys to reach SHND which allows you to select the Master Slave mode Sound active SoUn then lt ENTER gt to confirm Auto CoLo then Auto then lt ENTER gt to Color CoLo then CoL 1 CoL 7 lt ENTER gt To set a custom color in Master Slave Standalone Mode Using this function you can select any color by adjusting the Red Green and Blue from 0 255 You can also use this function to adjust the overall white balance of the fix ture while running in any mode Please note that modifying the values in this step will affect ALL modes therefore we recommend resetting all levels to their highest value 255 after using this mode 1 Select NAnu from the control panel then hit lt ENTER gt 3 3 Choose rEd GrEE or bLuE then hit lt ENTER gt to confirm 3 Using the lt UP gt
6. arts are not restricted and that unit s ventilation is not obstructed Verify that 220V 110V switch is in the correct position if applicable Also check that speed channels are set appropriately Verify that the fixture is in Sound Active mode Adjust Audio Sensitivity If Applicable Make sure all connectors are seated properly and securely Use Only DMX Cables Install a Terminator Check all cables for defects Reset fixture s Check lamp for properly installation Re lamp lamp may have reached end of life Verify remote control cable is installed properly and securely Verify remote is correct type CA 9 or other as applicable Verify proper mode of operation Is the fixture in Auto mode wdmlighting com 4106 Harry Hines Bivd Dallas Texas 75219 800 893 9787 ColorFlat 9 RGB WEI educate create collaborate Tech Specs width Weight Operating Voltage 90 230VAC 50 60 Hertz Fuse 3A 250V Power Consumption 90 watt 65 watt for the 3 watt LED Fixture Light Source LED 9 x 9 Watt TriColor LED s 60K hrs 9 x 3 Watt TriColor LED s 60K hrs Beam Angle 25 degrees Max Operating Temp 104 degrees F 40 degrees C ambient Standalone Master Slave Sound Active Other Operating Modes Color Preset Standalone color mixing wdmilighting com 4106 Harry Hines Blvd Dallas Texas 75219 800 893 9787
7. can carry a high quality signal and are less prone to electromagnetic interference For instance Belden 9841 meets the specifications for EIA RS 485 applications Standard microphone cables will probably be OK but note that they cannot transmit DMX data as reliably over long distanc es In any event the cable should have the following characteristics 2 conductor twisted pair plus a shield Maximum capacitance between conductors 30 pF ft Maximum capacitance between conductor amp shield 55 pF ft Maximum resistance of 20 ohms 1000 ft Nominal impedance 100 140 ohms wdmlighting com 4106 Harry Hines Bivd Dallas Texas 75219 800 893 9787 ColorFlat 9 RGB WEI educate create collaborate 4 OPERATING ADJUSTMENTS NOTE After making any adjustment the fixture will return to the correct mode after approximately 5 seconds DMX Mode Allows the unit to be controlled by any universal DMX controller 1 The default mode for the fixture is DMX which appears as Addron the LED Readout Use the lt ENTER gt button then the lt UP gt and lt DOWN gt buttons to choose a channel between 1and 512 Press lt ENTER gt again to confirm 2 To change between 3 and 6 channel DMX mode select ChNd then press AENTERS Select either 6Chor 3Ch then press lt ENTER gt again to con Master Slave Mode Auto Sound Active Color Preset Custom Allows you to link up to 32 units together without a controller 1 Use stand
8. damaged e Never disconnect the power cord by pulling or tugging on the cord e Avoid direct eye exposure to the light source while it is on Caution There are no user serviceable parts inside the unit Do not open the housing or attempt any repairs yourself In the unlikely event your unit may require service please contact WDM Lightning at 800 893 9787 wdmilighting com 4106 Harry Hines Blvd Dallas Texas 75219 800 893 9787 ColorFlat 9 RGB WEI educate create collaborate 2 MEET The ColorFlat 9 RGB LED PAR Can CONTROL FEATURES e RGB color mixing via 9 x 9 Watt TriColor LEDs also Available in RGB color mixing via 9 x 9 Watt TriColor LEDs e Variable electronic strobe e Variable electronic dimmer e Built in automated programs via DMX and master slave e Built in sound active programs ADDITIONAL FEATURES e Lightweight and Compact e 4 Button LED control panel for easy programming e Light source 9 x 9 Watt LEDs Tri Color also available in Light source 9 x 3 Watt LEDs Tri Color e Dual bracket for flexibility in mounting e Power outlet for fixture linking up to 10 fixtures DMX Quick Reference 6 Channel Mode Built in Programs Dimmer DMX Quick Reference 3 Channel Mode wdmilighting com 4106 Harry Hines Blvd Dallas Texas 75219 800 893 9787 ColorFlat 9 RGB VAC educate create collaborate Figure 1 The ColorFlat 7Pin Up Picture Dual Mounting Tri Color LEDs Yokes Fi
9. gure 2 The Rear Connections DMX In DMX Out LED Control Panel AC Power In Out Microphone wdmilighting com 4106 Harry Hines Blvd Dallas Texas 75219 800 893 9787 ColorFlat 9 RGB WEI educate create collaborate 3 SETUP Before replacing a fuse disconnect power cord ALWAYS replace with the same type and rating of fuse Fuse Replacement With a flat head screwdriver wedge the fuse holder out of its housing Remove the damaged fuse from its holder and replace with exact same type fuse Insert the fuse holder back in its place and reconnect power Connecting A Bunch of ColorFlat 7Flat LED PAR Cans You will need a serial data link to run light shows using a DMX 512 controller or to run shows on two or more fixtures set to sync in mas ter slave operating mode The combined number of channels required by all the fixtures on a serial data link determines the number of fix tures the data link can support Fixtures on a serial data link must be daisy chained in one single line Also connecting more than 32 fixtures on one serial data link without the use of a DMX optically isolated splitter may result in deterioration of the digital DMX signal The maximum recommended cable run distance is 500 meters 1640 ft The maximum recommended number of fixtures on a serial data link is 32 fixtures Data DMX Cabling To link fixtures together you ll need data cables You should use data grade cables that
Download Pdf Manuals
Related Search
Related Contents
Bedienungsanleitung Instruction manual Mode d V12N 1.Spr. S.001-039 Kopie ST-110 Coin Wizard Electronic Totalizer Users Manual タカショーの5年保証 Manuel d`utilisation Klaro quick AIDE à l`utilisation du cédérom « L`athlétisme à l`école Brodit ProClip 854915 i3TOUCH V-SENSE Cisco Jabber Video for TelePresence 4.7 User Guide for Windows Le marketing sans marketing Copyright © All rights reserved.