1. 5 1 1 Maximum cable length RS 232 IEEE has specified the maximum cable length for an RS 232 connection to 15m Longer distances can be installed depending on the environmental conditions of the installation site It is the responsibility of the installer user to secure a proper installation of the RS 232 connection nevion com 12 VikinX Sublime Control Panels Rev 5 5 2 Ethernet connection The connections follow the standard set by the IEEE 802 3 100BaseTX specification The cables that are to be applied should be CAT 5 CAT 5E standard or better It is the responsibility of the installer user to secure a proper installation of the Ethernet connection All VikinX Sublime routers and IP based Control Panels are connected together through an Ethernet Switch A VikinX Sublime device has only one physical Ethernet connection If redundant control is required this limitation has to be solved by the control system For Ethernet protocol details concerning this router please refer to the following manual Modular Router Control Protocol This manual can be found on our web site http www nevion com 5 2 1 HW limitations With the introduction of Sublime controller HW Rev 2 the user has the option of connecting more than two devices together without having a Multicon to control the network See Chapter 3 7 for verification of the HW revision of your device Unless you apply a Multicon as a system controller th
2. 2 3 Control Standard Features Serial port Connector s NCB ports Connectors 2 Ethernet port Connector Weight incl 1x PSU Current 15V Current 15V Power 1 0 kg 300 mA 3 MA 5 W 1 0 kg 300 mA 3 MA 5 W 1 2 kg 400 mA 3mA 6 W 1 0 kg 300 mA 3mA 5 W 1 0 kg 300 mA 3mA 5 W 1 0 kg 250 mA 3 mA 4W 1 2 kg 400 mA 3 mA 6 W 1 4 kg 300 mA 3 mA 5 W 1 0 kg 300 mA 3 mA 5 W 1 3 kg 400 mA 3 mA 6 W 2 1 kg 300 mA 3 mA 5 W 1 4 kg 300 mA 3mA 5 W 1 6 kg 400 mA 3mA 6 W 0 35 kg N A AC Mains 40W Power Supply Unit 100 240VAC 50 60Hz Max 1 64 IEC 320 15V max 2 2A 15V max 1 35A Maximum 43W DB9 female Via LED in front of the router CP Compliant with CE EN60950 UL 1950 CSA22 2 RS 232 for protocol conversion to VikinX compact control protocol or to third party protocols DB9 female For integration with VikinX compact router configuration RJ45 1 In 1 Out 10 100BaseT Ethernet bus for external router control RJ45 nevion com 5 VikinX Sublime Control Panels Rev 5 2 4 Connection details The Sublime routers and control panels have the following service connections on the rear of each product SN dle CONFIGURATION p CONFIGURATION j y DIP 1 4 ADDRESS LEVEL DIP 5 6 ROUTER MODE DIP POWER ALARM DIP8 POWER UPMODE ICS ASA Made in Norway NCB IN NCB OUT ETHERNET RS 232 POWERA POWER B J f o fooaoo IQA SL Figure 1 Sublime service connectors SYNC Not in u
3. nevion Control Panels in the VikinX Sublime series User manual Rev 5 VikinX Sublime Control Panels Rev 5 Nevion Support Nevion Europe 1600 Emerson Avenue P O Box 1020 Oxnard CA 93033 USA 3204 Sandefjord Norway Toll free North America 866 515 0811 Support phone 1 47 33 48 99 97 Outside North at 1 805 247 Support phone 2 47 90 60 99 99 Nevion USA E mail support nevion com See http www nevion com support for service hours for customer support globally Revision history Current revision of this document is the uppermost in the table below Rev Repl Date Sign Change description 5 4 2009 10 07 NBS Added Chapter 2 1 1 Updated Chapter 5 2 with new information about Ethernet connectivity Added extra information about A V Toggle button in Chapter 7 4 3 2008 12 05 NBS Remover PSU alarm GPI information 3 2 2008 11 05 NBS Added corrected GPI wiring information Added protocol configuration information Added description of power pinout 2 1 2008 02 13 NBS Added footnotes on extra buttons in Chapter 1 1 1 0 2008 01 25 NBS Updated with GPI I O information 0 2008 01 03 NBS First release nevion com 2 VikinX Sublime Control Panels Rev 5 Contents DEPPOCUCHONEVIE WA E AAA AAA 4 Tal iPFOQUCEVErSION Sai Aa tt A 4 ZS PREMIA ON ria AA AA AR KELER EE KE taah 5 A O sa 5 2 1 1
4. MIDI repeater units To avoid grounding problems all NCB ports have opto coupled inputs nevion com 15 VikinX Sublime Control Panels 6 GPI connections Rev 5 This information is only applicable on GPI versions The GPI Joystick Tally signals are connected to the Sublime Control Panel with GPI options using DB25 male connectors Each Sublime CP with GPI I O has 32 CPI inputs and 32 GPI outputs available independent of panel size The GPI connectors on the CP are DB25 females The following pinout applies GPI I O Channel Connector pin 1 and 17 12 2 and 18 24 3 and 19 23 4 and 20 10 5 and 21 09 6 and 22 21 7 and 23 20 8 and 24 07 9 and 25 06 10 and 26 18 11 and 27 17 12 and 28 04 13 and 29 03 14 and 30 15 15 and 31 14 16 and 32 01 Inputs are internally connected to 5V via a pull up resistor The inputs will be activated when pulling them to ground Ground is available on the following pins 2 5 8 11 13 16 19 22 25 and on the connector chassis Outputs are of open collector type An output can switch a maximum load of 100mA at 30V Any device to be controlled by the GPI outputs lamp LED or similar needs to be connected to an external supply voltage on one end and to the CPI output on the other end Warning Do not connect external supply voltages higher than 30V DC nevion com 16 VikinX Sublime Control
5. Panels Rev 5 7 Control Panel operation All local control panels are completely configurable with the System Configurator which is downloadable from the Support pages at http www nevion com All local control panels are given a default configuration which includes the buttons A V Toggle Panel Enable Take on off and Take In addition input and output buttons are preconfigured The extra buttons on the 2RU and 4RU panels are not preconfigured They may be configured by the user Note that GPI functions are not programmable on Sublime GPI CP s They have a fixed preconfigured function described earlier in Chapter 3 7 1 Button description A V Toggle The A V Toggle button enables disables audio and video on a specified address The address can either be read from the dip switches or be fixed The button toggles between three states The user may program more than one A V Toggle buttons one button for each router level that the user wants to control See Chapter 5 2 1 and the Nevion Configurator User Manual for further details If the button is pressed for more than 1 second it will go into a fourth state where both audio and video are disabled In this state the button will be dimmed If the button is pressed for more than 1 second again it will enable both audio and video if present Button Color Video Enabled Audio Enabled Yellow Yes Yes Green Yes No Red No
6. Yes Dimmed No No If neither audio nor video is present it will be marked as disabled and the toggle state will not be used Toggle status changes will be stored in flash and used when the panel is powered up later When a panel is powered on it will search for connected routers If no routers are found the A V Toggle button will be disabled no light in the button This can happen if the panel is powered up before any routers are connected or if there is something wrong with the cabling To re enable the A V Toggle do the following 1 Activate the Panel Enable button Green light 2 Push amp Hold the A V Toggle button for 2 seconds nevion com 17 VikinX Sublime Control Panels Rev 5 The A V Toggle button should now be activated and the light turned on Panel Enable If a Panel Enable button is present the panel will start up not enabled In this state the button will be red and all the other buttons will be disabled When pressing the button the panel will be enabled and the color will change to green A status request will also be sent to get information on active levels If no Panel Enable button is present the panel will start up enabled Take on off The Take on off button enables or disables the Take button If no take button is defined Take on off is always off On first start up the take button is enabled Later it will read the last status from the flash memory Activating
7. buttons on the front of the panel GPI inputs 1 32 cannot be reconfigured to represent other inputs e they are fixed inputs 1 32 operating on the selected output XY An Input to Output XY button switches a preset input to a preset output on all enabled audio and video levels If the Take button is enabled the switch will not be executed until the Take button is pressed nevion com 18 VikinX Sublime Control Panels Rev 5 The maximum router size s that may be controlled without Multicon is formed by IN 1 128 and OUT 1 64 router size 128x64 This size limitation is regardless of the number of routers the control panel s is are controlling See also the limitations 1 and 2 in Chapter 5 2 1 Salvo A Salvo button switches a sequence of cross points This is done even if the specified audio or video level is disabled Maximum Salvo size that may be configured without Multicon is limited to 128 X points Lock A Lock Toggle button toggles the lock status on the active output on all enabled audio and video levels If the active output on any of the enabled levels is locked before pressing the button they will be unlocked If not the active output on all enabled levels will be locked A locked output can t be switched nevion com 19 VikinX Sublime Control Panels Rev 5 General environmental requirements for Nevion equipment 1 The equipment will meet the guaranteed performance specification
8. example shows connection of 4 VikinX devices with RJ45 connectors and bus termination IN OUT Figure 4 NCB loop configuration Note that each device at the end of the chain has a termination plug indicated with the letter T This termination plug must be inserted in the correct connection port If not no NCB communication is possible nevion com 14 VikinX Sublime Control Panels Rev 5 5 3 3 Termination plug The termination plug that is mentioned in the previous chapter is necessary when you want to avoid closing the loop be a long cable The termination plug is a standard RJ45 plug with the following internal wiring Lu Figure 5 NCB loop termination plug As seen in the figure above Pin 3 is connected to Pin 4 and Pin 5 is connected to Pin 6 5 3 4 Control bus structure The Network Control Bus structure follows the standard MIDI bus definition The NCB is defined as a closed chain of units This means that the NCB OUT of the last unit must be connected to the NCB IN of the first unit in the NCB chain To avoid problems with the control of VikinX units the installer user has to assure that the bus structure is installed according to this definition The total number of VikinX devices in an NCB chain is limited to 50 5 3 5 Maximum distance between NCB devices The standard MIDI definition allows a maximum cable length of 200 250 meters between two devices Longer distances can be made with
9. priority of the GPI panel either to release before switch or to switch before release Release before switch Used in both GPI and Joystick mode The activation of a new input line will have no effect until the previous line is released If more lines are activated in sequence the latest activated one will result in a switching as soon as the previously active is released Switch before release Used in both GPI and Joystick mode The activation of a new input line will generate a switching regardless of how many other lines that are already set The priority can be switched according to the following pattern SW 6 Joystick priority OFF Switch before release ON Release before switch Default mode is Switch before release 3 4 Power alarm The power alarm can be switched according to the following pattern SW 7 Power alarm OFF Disables Power Alarm ON Enables Power Alarm Default setting is Power alarm disabled 3 5 Joystick mode This information is only applicable on GPI versions Switch 8 on the configuration switch set the Joystick mode of the GPI panel either to GPI mode or to Joystick release mode GPI mode Releasing the input lines will keep the previous status Operation of the front panel is allowed with any number of active GPI lines simultaneously Joystick release mode When all the input lines are released a default input either dynamically cho
10. 6S CP GPI Single bus 16x1 panel with GPI Joystick Tally interface SL 32S CP Single bus 32x1 panel SL 32S CP GPI Single bus 32x1 panel with GPI Joystick Tally interface Control Panels 19 2RU SL 32XY CP Multi bus X Y 32x32 panel SL 64S CP Single bus 64x1 panel SL 64S CP GPI Single bus 64x1 panel with GPI Joystick Tally interface Control Panels 19 4RU SL 64XY CP Multi bus X Y 64x64 panel 1 Sublime 2RU Control Panels come with 2 additional programmable buttons on the bottom left side These buttons may be programmed in the same way as any of the other programmable buttons Sublime 4RU Control Panels come with 6 additional programmable buttons on the bottom left side These buttons may be programmed in the same way as any of the other programmable buttons nevion com 4 VikinX Sublime Control Panels Rev 5 2 Specifications 2 1 Mechanics Dimensions Safety Emission standards HxWxD 44x483x50mm 19 1RU HxWxD 88x483x50mm 19 2RU HxWxD 176x483x50mm 19 4RU Compliant with CE EN55103 1 and 2 2 1 1 Weight and power consumption Device SL 8XY CP SL 8S CP SL 8S CP GPI SL 16XY CP SL 16D CP SL 16S CP SL 16S CP GPI SL 32XY CP SL 32S CP SL 32S CP GPI SL 64XY CP SL 64S CP SL 64S CP GPI SL PWR 40 PSU 2 2 Power Supply SL PWR 40 AC Supply voltage range AC Mains connector DC output DC connector Status monitoring Safety standards
11. ON 4 OFF ON OFF OFF 5 OFF ON OFF ON 6 OFF ON ON OFF 7 OFF ON ON ON 8 ON OFF OFF OFF 9 ON OFF OFF ON 10 ON OFF ON OFF 11 ON OFF ON ON 12 ON ON OFF OFF 13 ON ON OFF ON 14 ON ON ON OFF 15 ON ON ON ON 16 me doo o a lx Inia o jsou alwin 10 Default level is 1 3 2 It is possible to control more than 1 level with Sublime panel See Chapter 7 1 A V Toggle for more information Fallback mode This information is only applicable on GPI versions Switch 5 on the configuration switch sets the fallback mode of the GPI panel either to dynamic or to hard set This is only useful when the GPI panel is in Joystick release mode see Chapter 3 0 Dynamic fallback mode When the GPI is activated the X point status is saved before switching When the CPI is released again the panel will switch back to the previous saved X point status Hard set fallback mode When the GPI is released the panel will switch to a previously configured fallback input The fallback input is configured using the input buttons see Chapter 7 1 nevion com 7 VikinX Sublime Control Panels Rev 5 The modes can be switched according to the following pattern SW 5 Fallback mode OFF Hard set ON Dynamic Default mode is Hard set 3 3 Joystick priority This information is only applicable on GPI versions Switch 6 on the configuration switch set the Joystick
12. Weight and power Consumption stand 5 LIZ POWER SOON a E 5 ZO CON MO dd idos a Sard 5 ZA CONNECT is 6 2 4 1 Power Supply PINO A ANA ates 6 5 Configuration cio suetacgaevenetueawadean acoe seepscseeb on genesecaacpnevewacuganepscereboncsaeenes 7 3 1 Leve CONAGUA Ol A A A tease AA A 7 3 2 Fallback MOC tii T ta 7 IS OV SUCK PON e a a ia ls 8 3 4 POWEL al al Mics fees cas ccss E ti lo 8 3 5 Joystick MO asi A 8 3 6 Configuring output on Single bus panels oonooccccnnnocccccnnnoncnnnononannnnnnonannnnnnnannnccrnanononnos 9 3 7 Configuring protocol Options cidad a as 9 4 LED status INOICA MON daa aan ita 11 AA o A awanhbat awe 11 42 Alarmi State Sore neren ne A Sea vue donee E E E LE AAA Cen AEE ii tes 11 AAA A O A A A ied T 11 5 Router COMMUNICAON rata Ate ata 12 Sol Serial CONNEC ION dc 12 5 1 1 Maximum cable length RS 23 8 Leitte cil eaipi dida 12 52 Ethernet CONNECEON r ii dd eee ceeus eck 13 SL AA aa TETEE DEE A A A T ET A 13 5 3 NCB COMMECUON a A A TOA NAAA 14 5 3 1 Connecting control panels ani o a id 14 5 3 2 Pin out and cable type is ia id 14 53 3 Termination PlU gresso tt lll dida 15 5 3 4 Control DUS Str Ct re sienak ennn n a i a a a a a a a a a t 15 5 3 5 Maximum distance between NCB devices ccooocccnoccnonoccnnnoconocccnniconnnocanunccnnarccnanannnos 15 6 GPI COMMECHONS A ai 16 7 Control Panel operas aaa ai 17 7 1 Button description ata 17 General environmental requirements for Nevion equipment eeeeeeee
13. a GPI I O will not influence the Take on off function nor will a Take on off function influence the activation of a GPI I O function Take The Take buttons LED is normally off If the Take on off button is set to on no commands will be sent from the panel until the Take button is pressed The last selected buttons and the take button will blink until the Take button is pressed and the command is sent from the panel Activating a GPI I O will not influence the Take function nor will a Take function influence the activation of a GPI I O function Output An Output button is used for selecting an output Selecting an output activates it so that it is switched to the next input that is selected Input An Input button switches the active output to the selected input If the Take button is enabled the switch will not be executed until the Take button is pressed When switching using the Input button all enabled audio and video levels will be switched from the selected input to the active output The Input button can also be used to select the active output This is useful on single bus panels It requires that a Panel Enable button is present When the panel is enabled press the Panel Enable button and hold it while selecting the active output by pressing an Input button Then release the Panel Enable button The panel will now be disabled Press the Panel Enable button again to enable it Note that unlike the
14. anels Rev 5 5 Router communication You gain access to router for communication purposes by connecting either the router s serial port to your computer or by using an Ethernet connection Do not use both the router s Ethernet port and RS 232 serial port or NCB ports at the same time Doing so may cause loss of important communication and control data 5 1 Serial connection Connection can by made trough the serial port s of the router see also Chapter O for connection details The communication parameters are configurable Please refer to the protocol documentation of the appropriate communication control protocol Example The protocol parameters of the VikinX Compact routers are as follows Bit rate 19200 bit s Data bits 8 bits Stop bits 1 Parity No parity For further details concerning this protocol please refer to the following manual NCB Protocol pdf The DB9 female connector for the serial port s of the router has the following pin out Pin RS 232 mode 1 Not in use Tx Rx Not in use GND GND RTS CTS Do Not Connect Note that if the standard RS 232 cable specification DCE is followed 0 00 Ni OV Qi BY WW Nh A cable with Male Male or Female Female connectors at the cable ends is used for Rx Tx crossed connection and A cable with Male Female connectors at the cable ends is used for a straight through connection
15. e limitations that apply are 1 One Sublime control panel may connect to a maximum of 4 Sublime routers 2 One Sublime router may be controlled by a maximum of 4 Sublime control panels Exceptions to the above limitations A router with a local CP e g SL V6464 CP may only connect to 1 other router Both routers must be configured with the same address and be of different type A V Example 1x SL V6464 CP may only control itself 1x Audio router AA or AES Both routers must be configured with the same address 16x2 routers that are expanded to NNx2 are using the NCB bus for this purpose The total NNx2 router is therefore counted as 1 router in the limitations 1 and 2 above From limitations 1 and 2 above the resulting Ethernet configuration may consist of maximum 8 devices 4 routers and 4 control panels with the exceptions mentioned above An example is illustrated in the figure below System Configurator Physical connections Control lines Ethernet lines SL router SL CP e St router e Vedd LS 64x2 aie N A na a A named id nee Sho nf a 34 nis de p Wy SAS N port MAS YI Yeo hey erer pj cinoma d A 604154 x 7 Switch ay Sa A ny eS Y SL CP k J SL CP SL routar Bixi NA hanes DS Texte PEET Sa 77 y ADA ADIDGZ Figure 3 Ethernet connections and configuration nevion com 13 VikinX Sublime Control Panels Rev 5 Refer to the System Config
16. ead in solder Some circuit boards may contain battery backed memory device nevion com 23
17. eeeeeeeeee 20 Prod ct Warranty OA is 21 Important notes regarding Software in the VikinX Sublime router family range 22 Appendix A Materials declaration and recycling information ccccccononcnannnonecos 23 nevion com 3 VikinX Sublime Control Panels Rev 5 1 Product overview Nevion are proud to present the 2nd generation of the compact small and medium routing switcher family Sublime With Sublime Nevion now provide a stable and proven product line including the most complete signal format and size offering available With the new ultra slim multi format and flexible product range Sublime fulfils the most demanding requirements from the professional broadcast market VikinX Sublime provides many of the powerful control features that drove the VikinX Modular range to success VikinX Sublime is ideal for general purpose facilities on air routing mobile outside broadcast applications and sophisticated A V applications This user manual presents the features installation and operation procedures of the control panels of the Sublime range 1 1 Product versions The following versions of the VikinX Sublime Control Panels are available Control Panels 19 1RU SL 8XY CP Multi bus X Y 8x8 panel SL 8S CP Single bus 8x1 panel SL 8S CP GPI Single bus 8x1 panel with GPI Joystick Tally interface SL 16XY CP Multi bus X Y 16x16 panel SL 16D CP Dual bus 16x2 panel SL 16S CP Single bus 16x1 panel SL 1
18. ere are two LEDs located at the Ethernet bus At start up the boot loader is searching for update commands on the serial port for about two seconds During this sequence both Ethernet LEDs will be blinking After the start up sequence the LEDs will indicate the Ethernet state 4 2 Alarm states The LED can either be red R green G yellow Y or have no light N The LED state is here described with twenty letters each representing 100ms which totals to an alarm sequence of two seconds The X indicates that the LED keeps the color it has the moment the alarm sequence begins green yellow or no light Description LED state Alarm Comment Continuous GGGGG GGGGG GGGGG GGGGG No alarm green light Status is OK Continuous YYYYY YYYYY YYYYY YYYYY Unable to This alarm will be yellow light connect to overwritten by other controller over alarms Ethernet Long red RRRRR NNNNN RRRRR NNNNN Power is too blinks low One short RXXXX XXXXX XXXXX XXXXX Power A failed Only active if power red blink alarm dip is set Two short XXXXX XXXXX RXRXX XXXXX Power B failed Only active if power red blinks alarm dip is set 4 3 Ethernet states The LEDs that are located at the Ethernet bus will after the Start up sequence indicate the Ethernet states On Off Blinking Green Valid link No link Yellow No data Data is transmitted or received nevion com 11 VikinX Sublime Control P
19. quired information Toxic or hazardous substances and elements MRA a R H AE RKE 3R FM Part Name Lead Mercury Cadmium Hexavalent Polybrominated Polybrominated Pb Hg Cd Chromium biphenyls diphenyl ethers Cr VD PBB PBDE All products referred to in O O O O O O Chapter 1 1 SL PWR 40 O O O O O O O Indicates that this toxic or hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement in SJ T11363 2006 X Indicates that this toxic or hazardous substance contained in at least one of the homogeneous materials used for this part is above the limit requirement in SJ T11363 2006 Parts without any of the above mentioned hazardous substances are indicated by the product marking e A 2 Recycling information Nevion provides assistance to customers and recyclers through our web site http www nevion com Please contact Nevion s Customer Support for assistance with recycling if this site does not show the information you require Where it is not possible to return the product to Nevion or its agents for recycling the following general information may be of assistance Before attempting disassembly ensure the product is completely disconnected from power and signal connections All major parts are marked or labeled to show their material content Depending on the date of manufacture this product may contain l
20. se on Control Panels LOOP Not in use on Control Panels NCB IN Network Control Bus Input The protocol of this bus is described in a separate manual NCB OUT Network Control Bus Output ETHERNET 10 100Base T Ethernet bus for external router control RS 232 RS 232 for external control protocols POWER A 15VDC power connector POWER B 15VDC power connector redundant supply CONFIGURATION Configurations switch See Chapter 3 for further descriptions 2 4 1 Power Supply pinout The DB9 power pinout for Sublime routers and Control Panels are as follows Pin Description 1 GND Not connected Not connected 15VDC Not connected Not connected Not connected 15VDC Not connected 0 00 NJ OV Qi AWIN nevion com 6 VikinX Sublime Control Panels Rev 5 3 Configuration This chapter provides an overview of the configuration options that are available on the Sublime Control Panels 3 1 Level configuration Switches 1 4 on the configuration switch set the CP s level for communication with the Router Management System and other units in the NCB system Panels on the NCB dedicated to operate with the router must be configured to the same level as that router The levels can be switched according to the following pattern SW1 SW2 SW3 SW4 Level NCB Address OFF OFF OFF OFF 1 OFF OFF OFF ON 2 OFF OFF ON OFF 3 OFF OFF ON
21. sen or static is set The front panel is locked if any of the input lines are active The modes can be switched according to the following pattern SW 8 Joystick mode OFF GPI mode nevion com 8 VikinX Sublime Control Panels Rev 5 ON Joystick release mode Default mode is GP mode 3 6 Configuring output on Single bus panels See Chapter 7 1 section Input for configuring default output to be controlled from a Single bus control panel 3 7 Configuring protocol options For various reasons Nevion has decided to make it possible to turn the extra commands that were added to the NCB protocol when we introduced the Sublime router range either off or on At the same time the user must select whether he she shall use the RS 232 port for controlling the router or the Ethernet port This is done in order to prevent both ports from simultaneously being applied for controlling the router There is a new Protocol field in the System Configurator where you may choose from the following options NCB without Sublime ext RS232 This is the old Compact NCB protocol without Sublime extensions If used on a Sublime it also disables the Ethernet port of that device This is the default option for the Sublime Compact SC range of products NCB RS232 This is the regular Sublime protocol with the extra commands that were added to the NCB protocol If used on a Sublime it also disables
22. the Ethernet port of that device This is the default option for the Sublime SL range of products MRP TCP IP This option is only applicable to the Sublime range It selects the Ethernet protocol as the control option and disables the RS 232 port of that device Note that the above selection is only possible if you have Sublime FW rel 2 1 1 or newer installed on your Sublime device Note also that the above selection can only be made via System Configurator rel 3 3 5 or newer installed on your PC It is NOT possible to select protocol options on Sublimes with HW rev 1 Use your System Configurator to verify the HW revision of your Sublime unit iSoGSssscs Figure 2 HW verification in Nevion Configurator nevion com 9 VikinX Sublime Control Panels Rev 5 Right click the column headers and select the appropriate column to be shown if you don t see the appropriate column in your default display For further information about FW releases please go to the Nevion web site to download or check available FW releases www nevion com nevion com 10 VikinX Sublime Control Panels Rev 5 4 LED status indication 4 1 Start up The LED located at the front of the control panel indicates the status of the panel At start up the LED will alternate between red R and green G every 500ms for about two seconds After the start up sequence the LED will indicate the Alarm state of the panel Th
23. under the following environmental conditions Operating room temperature range 0 C to 45 C Operating relative humidity range lt 95 non condensing 2 The equipment will operate without damage under the following environmental conditions Temperature range 10 C to 55 C Relative humidity range lt 95 non condensing nevion com 20 VikinX Sublime Control Panels Rev 5 Product Warranty The warranty terms and conditions for the product s covered by this manual follow the General Sales Conditions by Nevion which are available on the company web site www nevion com nevion com 21 VikinX Sublime Control Panels Rev 5 Important notes regarding Software in the VikinX Sublime router family range This product utilizes software components that are licensed with open source licenses The source code for these components and our modifications are available from http labs nevion com open source OpenTCP includes software developed by Viola systems http www violasystems com nevion com 22 VikinX Sublime Control Panels Rev 5 Appendix A Materials declaration and recycling information A 1 Materials declaration For product sold into China after 1st March 2007 we comply with the Administrative Measure on the Control of Pollution by Electronic Information Products In the first stage of this legislation content of six hazardous materials has to be declared The table below shows the re
24. urator User Manual for further information about the above described configuration connection options It is NOT possible to connect more than 2x Sublimes with HW rev 1 together via Ethernet unless a Multicon is applied as system controller 5 3 NCB connection Via the Network Control Bus system several routers and control panels can be interconnected Up to 16 levels of routers or combinations of routers can be controlled The NCB system and all RS 232 ports interchange the system status This means that any control system either from Nevion or from a third party manufacturer connected to any RS 232 port in the NCB loop will have access to all communication data on the bus 5 3 1 Connecting control panels To get a control panel working with a specific router configure the control panel to the same level as the router Several panels can be configured to control the same router Panels can also be connected to a router via the RS 232 interface Please refer to your control panel manual for installation 5 3 2 Pin out and cable type VikinX Sublime routers and Control Panels use RJ45 connectors for the Network Control Bus ports The following pin out is used Pin 1 Not Connected _ Pin 2 Not Connected ange amd TH L Pin 3 Data retour 6 Pin 4 Data Green Blue 15 Pin 5 Data Pair N Pairt TH Pin 6 Data retour Orange t2 y Pin 7 Not Connected Pair A Pin 8 Not Connected The following connection