1. TrendManager or TrendServer database to analyze and document specific batch process This tool uses the recorder batch information that has been imported into the TrendManager software eliminating the error prone steps of manually entering the data into a spreadsheet application This tool allows a user to generate separate batch report in a secure PDF format to document the final results of the batch process TrendServer Pro with OPC Server provides the same functions as the TrendServer Pro but includes the added function of an integrated OPC DA 2 0 compliant Server to allow easy interfacing to third party HMI software packages that support an OPC Client This provides a real time interface between servers and clients TrendManager Suite The batch report contains the following details as part of the report Features TrendViewer TrendManager TrendServer Data Conversion Tool to import graph save and export data v v v from other Honeywell devices into the TrendManager no export Software mode Import data from removable media v v v Print all graph data and recorder configurations v v v graph data only Operates in Window 7 32 and 64 bit Professional v v v Enterprise and Ultimate Edition Windows 8 Windows 2008 Server and Windows 2012 Server Full Configuration of TrendView Recorders v Archive data on integral secure database v E mail recorder configurations and data on www v Co
2. 5 days 18 hours 48 mins 46 secs Figure 1 1 Hardware Wizard e Comms Includes Modbus Communications protocol for Ethernet and RS485 Web Browse your recorder using the web browse feature Email Setup email accounts to send alarm and event information SNTP Simple Network Time Protocols is a protocol for synchronising the clocks of computer systems and other devices over ethernet networks TCP IP Transmission Control Protocol Internet Protocol A protocol for communication between computers recorders and other devices Network Admin Network Admin is required for printers on a network and shared or work group printers FTP File Transfer Protocol Used to transfer data to and from the recorder Peer to Peer Sets up the recorder to be identified on a network e Events Counters Events are certain conditions or operations can be set up and logged according to the time and date of the occurrence Subsequently events can be reviewed in a list or represented on a graph Up to 16 User Counters are available and can be used as a part of the Events system User Counters can be set up as a Cause or an Effect of an Event Preset Markers can be configured and used when applying a Mark to the chart through the event system the alert system or manually Counters Up to 16 User Counters are available and can be used as a part of the Events system User Counters can be set up as a Cause or an Effect of an Event e Screen tab Brightness
3. BatchMode Jul 06 2661590 06 06 2007 10 08 56 C Program Files TrendMa H Ringwood BatchMode Jun 06 2661590 j Deleted Items Moved Items Archived Items Summary Source Path Destination Path C Program Files TrendManager Suite T MP5DB initial DatabaseVrchwes Dec 06 45Mb f H Ringwood BatchMode Database tool move 53GB free disk space Figure 1 6 Database Tool User Interface TrendManager Suite FTP Import Available on TrendServer ONLY TrendServer uses FTP IP File Transfer Protocol Internet Protocol this is the transfer of data between a computer and a recorder Secure Comms available on the GR Series recorders TrendServer offers the ability to import data from recorders via an Ethernet connection This is standard on all recorders with an Ethernet card Each recorder is identified by its name and a unique internet number known as an IP address Internet Protocol Address For more details on IP Addresses see your IT system administrator If the recorders and TrendServer are on the same local network a number can be selected from a range of pre allocated numbers Set up Add Edit or Remove the recorder you wish to import from Batch Select a number of recorders required for importing via FTP Schedule The Schedule button is for adding this recorder to a time date schedule to import data FTP Scheduler 14 External Import E Select type of import le Pen data and events C Setup on
4. Tue Mar 08 2005 15 05 10 End AMS2750 Mode is an option that can be enabled in the credit system of the X Series recorder AMS2750 is the specification that covers pyrometric requirements for thermal processing equipment used for heat treatment TrendManager Suite supports the configuration of the recorder and has two capability modes to match with the mode set in the recorder In process mode sets of timers are configured to inform and alert the user to the status of certain conditions these include Temperature Uniformity Survey TUS System Accuracy Tests Instrument Calibration due date Control TC due date and TC Status In TUS mode the recorder is configured to run a survey based on sensor and furnace settings in the recorder These must be configured in line with AMS2750 specification Refer to the User manual for more details A separate software program is used to generate the survey report using the TUS temperature uniformity survey file generated by the recorder TrendManager Suite TrendServer Pro Features IQOQ Protocol Document The IQOQ protocol product is for the eZtrend Minitrend and Multitrend recorders The manufacturer is obligated to execute a Validation Protocol for every piece of equipment that is associated with a critical process The IQOQ feature aids in doing this and comes with the TrendServer Pro software when ordering the IQ OQ part number 50032291 501 When ordering your IQOQ Protocol Tool two
5. allows Modbus devices other than the TrendView recorders to get real time data into Trend Server Pro TrendManager Pro TrendManager Pro is an advanced data analysis archiving software package providing full configuration of the TrendView recorders Communications Server The Communication Server is supplied with TrendServer Pro It manages real time communications distributed access to the stored data time synchronization over RS 485 and Ethernet networks is only for V5 not X Series or GR Series It is also available with an OPC DA 2 0 compliant Server to make it easier to interface third party HMI software packages that support an OPC Client The Communication Server provides security for the transmission and storage of process data TrendManager Pro is a stand alone package that provides the user the ability to create recorder configuration data archiving graphing and printing TMP also allows data to be exported using comma separated variables CSV format that can be imported into other computer software applications TMP imports data from various Honeywell recorders and stores the data individually in a secure database on a PC for graphing analysis adding comments later retrieval printing and export TMP has a Concurrent Batch Mode facility where markers can be entered via the recorder or IQOQ Protocol Document Option with TrendServer Pro only IQOQ Protocol Document Custom built IQOQ reports can be generated based on
6. can be installed on a different PC than TrendServer to manage communications over the whole network only one instance of the communication server is necessary on the network Administrator rights are necessary for setup and operation The Communication Server manages the Real Time communications with networked recorders using the Trendbus or Modbus protocol only Modbus comms is available on the X Series and GR Series recorders The data acquisition rates are specified at the PC and can be different from the ones used in the setup of the recorder Real time communications is the safest way of handling process data since it does not rely on data transport via the removable media of the recorders and the data is stored in the secure database immediately after acquisition Communications Server Of x Administration EEI Ei Database Servers a tams eted O laau Pans oaee Bades SB Loca Server unconnected None o 160 221 185 51 h Communication Ports Unconnected Wating i k 160 221 186 13 F comi 502 Unconnected None e 64 o 160 221 185 21 i nS COM2 Unconnected None e 64 oO 160 221 185 52 Ay oi Unconnected None 6 Qf 140 221 186 12 H Unconnected None oom a 160 22 186 26 p pea Unconnacted 6 160 221 186 160 E COMS COM6 colt com vot COMB 0 00 E Ethernet Total Sent 0 Messapes ave Total Receved O Messages i Cp 51 Bad Sert 1 Messages Cp 69 Bad Receive
7. collapsed by using grab bars at the top and bottom of the scale display The colour of the scale indicator signifies whether the data is historical data blue 8 or real time data orange 4 White scales indicate FTP or disk data Recorder data is displayed by dragging selected recorders 5 or pens from individual recorders into the graph window A System Status window 6 which can be hidden provides status information concerning communications the window will appear automatically if an error or connection problem occurs Review of the data is aided with the use of the Data Locator 7 and the mouse to scroll forward and backward in time The review of data can be done in both the historical and real time data windows the real time buffer can be set in the System parameters from 10 minutes to 2 hours The real time window can be paused and a cursor bar allows the user to view the digital values Other functions include Zoom In Zoom Out using the right button on the mouse switches are available to turn on or off selected display features like Point Markers of the actual data point the Recorder Name on the bar graphs indicators and Event Message boxes to view as Thin Traces and the Date Time of the Event Marker Turning these off does not erase the data it only changes what is being displayed at the time TrendManager Suite 12 Communications Server The Communication Server is a software application supplied with the TrendServer software It
8. in the management of configurations TrendManager Suite 5 e Displays a tabular window The Data Viewer Z Mote ACTUAL LOGGED DATA a value with astar after t has been logged att screen displays an overview of data currently Temperature Pression Vitesse visible in the graph window showing date Thu Aug 29 2006 15 32 28 9000 22 F OF 07 Thu Aug 29 2006 15 32 31 4700 22g O 0 time and value for each pen in column form Thu Aug 24 2006 15 42 56 1 800 33x ty ii This window can be resized to allow many Thu Aug 29 2006 15 43 26 1800 23 D O Thu 4ug 29 2006 15 43 56 1800 23 1 li pens to be viewed at once or the column width Thu Aug 29 2006 15 44 26 190 27 0 g i i Thu Aug 29 2006 15 44 56 100 23 Q may De adjusted to suit the user needs by Thu dug 24 2008 15 45 28 1200 oa e clicking on the gaps between the headings amp Thu 4ug 29 2006 15 45 56 1800 oy fr g i Thu Aug 29 2006 15 47 06 7100 27 i 0 dragging as in excel Individtiel rows can be Thu Aug 29 2006 15 47 35 7100 op re jr selected and copied by clicking on them while Thu Aug 29 2006 15 48 06 7100 27 0 iiy Thu Aug 29 2006 15 48 36 7100 23 1 Le holding down the Ctrl key or you can block Thu Aug 29 2008 15 4406 7100 3 D 0 copy all the data There is a copy button so all Thu Aug 29 2006 15 49 36 7100 27 or g th iectedidat b ied to th Thu Aug 29 2006 15 50 06 7100 ay 0 O pil aSr S A CASE OPIRE aG Thu Aug 29 2006 15 50 38 7100 23
9. the configuration of the recorder The configuration can be validated as a process of confirming that TrendManager Server to create separate batches of data that can be viewed graphed and exported to a spreadsheet TMP allows the user to set up the recorder s Events system including setting up Scheduled Events User Counters Embedded Process values and Present markers for easier configuration a piece of equipment or process meets the stated requirements to produce a regulated product See IQOQ Protocol Document on page 10 Database Management Tool The Database Management Tool is a separate software application that is supplied with TrendServer Pro software It TrendServer Pro TrendServer Pro is a fully network aware software package for real time viewing and archiving of data via communications to the recorder It supports all the capabilities of TrendManager Pro plus real time data provides the user with the ability to backup sort archive move and copy the data stored by the TrendManager Pro and acquisition and FTP access TrendServer Pro provides TrendServer Pro Software See Database Management Tool secure multi level multi user access to the recorder data on page 13 by various departments with security Standard features Batch Report Tool of TrendServer Pro include data archive tools graphing eater et This improves on the creation of specific Batch reports from printing import and export data facilities
10. 1 D 0 clipboard and then pasted into programs such as Word or Excel A print button will print all of the selected data or the complete window e Pen Data Source Viewer This will provide information like Pen Name Pen Type Recorder Name Database Name Server Name Options are Select all selects all data Copy selected data to clipboard which copies the selected data on to the Windows clipboard for pasting into such as Microsoft Word or Excel To Print selected data click on the Print icon to generate two boxes one to select the font required then click OK followed by the print setup box Hardware Configuration Wizard e V5 Recorders Allows you to enter all the recorder details for type of inputs Standard or Fast Scan the quantity set communications either Ethernet or RS485 RS232 Trendbus or the Modbus RTU option via RS485 or Ethernet e X Series Recorders Setup includes Analogue Inputs Outputs and Pulse options Relay Alarm Digital Input Output card options Standard fit is Modbus TCP IP slave mode and web over Ethernet DHCP std communications port and Modbus RTU slave mode via an RS485 port RS485 is an option on the eZtrend recorder e GR Series Recorders Setup includes Analogue Inputs Outputs and Pulse options Relay Alarm Digital Input Output card options Standard fit is Modbus TCP IP slave mode and web over Ethernet DHCP std communications port and Modbus RTU slave mode via an RS485 port RS485 is an o
11. 2012 Server e The TrendManager Suite is easy to use and is available in English French and German languages The software is simple to use with Drag and drop operations clear menus and logical configuration wizards to help the operator set up and analyze data from the recorders e IQ OQ Protocol Documents to support process validation can be generated based on the configuration of the recorder optional not included with TrendServer Pro TrendManager Suite 2 Modbus Profile Configuration Tool this is a tool that comes Trend Manager Suite Overview as part of the TrendServer Pro software that allows the user to The latest version of the Trend Manager Suite software set up Modbus Device Profiles for use by the Communications supports V5 X Series and GR Series recorders Server It allows the user to edit existing Modbus profiles or TrendViewer create new ones for alternate Modbus devices other than the TrendViewer displays graphs and prints the electronic TrendView recorders to get real time data into TrendServer data stored and imported from the recorder s storage Pro It can also be used to export Modbus profiles from one media It is available at no charge and is shipped with system so that they can be imported into another system It is every Honeywell paperless recorder used for enabling the setup of Modbus communications with non Honeywell devices that support floating point input registers in their Modbus memory map This
12. 255 48 000 20 000 1 00 000 80 000 5 60 000 Fe CEE Type Date Time Rec Description BD Fri Mar 31 2006 14 58 19 00 0001 Start Batch 1 start Fri Mar 31 2006 14 58 19 00 0001 User ID IDI o 9 g A amp Fri Mar 31 2006 14 58 19 00 0001 Description Full batch 1 4 Fri Mar 31 2006 14 58 19 00 0001 Lot Number Lotl OK Cancel 10 se 2006 Fri Mar 31 14 59 4 gt Ej SSeS 8 Press F1 for Help re ee 4 Figure 1 2 User Interface 1 Trend area is the area where the trend lines for the recorders are displayed Colours and thickness of the trends are the same as displayed on the recorder 2 Cursor right click the mouse process values date and time are displayed around a vertical cursor line Event bar shows in time when various system alarm digital user and event batch marker events occurred 4 Events box Displays a group of events batch events that are in a numbered tile in the Event bar Events not available for Realtime and Logged data via Modbus 5 Event Detail boxes The details of the events are displayed and printed on the graph in the Event Information boxes User comments Batch events appear on the printout and are saved with the data 7 Time and date bar provides time and date by month day hours minutes seconds and milli seconds Trend data can be expanded or collapsed in time by using the mouse left and right c
13. Control and Screen Saver Settings Also included here is the Charts tab Set up the chart speeds in three categories Fast Medium and Slow e Recording tab Scheduled Use this screen to set up a scheduled export of data Storage Alarm The storage alarm function is linked to the Error Alert system when there is a requirement for a time period to be set to alert the user before the storage media is full e Transfer Enables the Import and export of data by selecting the path for the data to be imported from or exported to e Hardware Can be added and removed according to the recorders current hardware setup The hardware information in TMP should always be the same as that of the recorder e Reports Can be generated manually or on a periodic basis using the event system to show daily weekly monthly totals max mins averages etc the reports can be printed e mailed as attachments or exported to the external media The reports will be in RTF format for use in MS Word or other compatible word processors TrendManager Suite TrendManager Suite Interface M Point Markers 11 Switches p 1 00 000 2 30 000 AO O00 m P 30 000 w 5 25 000 a z 20 000 40 000 20 000 E 15 aS o E 0 009 20 000 100 000 S 30 000 a 10 000 5 60 000 40 000 2 ooogE 2 0 0095 2006 Fri Mar 31_14 58 57 375 00 000 80 000 5 60 000 40 000 80
14. Technical Information Honeywell TrendManager Suite PC Application Software Configuration and Ani Specifications 43 TV 03 09 June 2014 The TrendManager Suite software is a Windows based PC package that complements the Honeywell line of data acquisition products It provides the capability to configure analyze and network recorders for data acquisition ver Pro Default GRAPHO01 raph Edit Window Help AA 4 84 46s 464 A Databases 2014 Fri Jan 03 12 09 01 257 tah BS Add New Database ES e FTPData Jantst 4th Add New Server LogData Jantst 4th J Local Server Archive Database at le EBRoEEa Multitrend SX 18 Pen 5 Historical FTP Crate ultitrend SX 18 Pen 4 Historical FT SO a a a 2014 Fri Jan 03 13 29 2I Press F1 for Help Waiting for reply from xs 821714 29 secs until oh wii eae 2014 Fri Jan 03 12 00 Ls e The TrendManager software ties your process together providing access to the recorder through the plant LAN or the Internet while keeping a high level of security e TrendManager provides the tools for real time communication data analysis and configuration for the entire family of GR Series X Series and V5 paperless data recorders e The software is designed for use on Windows 7 32 and 64bit Professional Enterprise and Ultimate Edition Windows 8 Windows 2008 Server and Windows
15. X Series and GR recorders use the Modbus protocol only Modbus Modbus protocols supported on Ethernet and Serial ports RS485 The Comms Server is a MODBUS master It has no slave capability The maximum speed of data transfer over MODBUS is 1 one reading per second The maximum speed of data logging of realtime MODBUS data is 1 one reading p S The Modbus protocol can be used to connect with other devices that support floating point values in their register maps Communications X Series and GR Series Communicate with up to 256 units on RS485 Ethernet RS485 communications Communicate with recorders using Ethernet TCP IP FTP Ethernet connection to transfer data and setups to and from an X Series GR recorder TrendServer only OPC Capability Optional OPC Server broadcasting for each pen Current Value Engineering units Zero span High EU low EU for communication with HMI software that supports and OPC 2 0 Client V2 and DA compliant OPC Historian A Windows based Client application is be used toview and access historical data from Trendview OPC Historian Server Time Synchronisation V5 For Honeywell recorders connected in Real time mode with Trendbus every 5 minutes For FTP transfer at the end of each scheduled download The recorders clocks are synchronised to the PC clock Time Synchronisation X Series and GR Series Simple Network Time Protocol SNTP is a protocol for synchro
16. aph can be saved printed and exported in a quick and easy operation Exported data can be defined to ensure only the exact data required is sent to an Excel spreadsheet Existing data can be searched by time and re organized by batch names numbers Batch Mode highlights e Retrospective Batches Creating batches for existing historic graphed data for individual viewing graphing and exporting to spread sheet e Seamlessly logging continuous data e Comprehensive visible event and batch information displayed on the graph e Elapsed batch time for comparison analysis e Simple search for Batch data On the recorder batch data can also be paused for viewing and resumed A batch can be aborted at any time if so this will not register as a batch a batch is only complete when it has been stopped The Batch menu is the setup menu where you can configure all the Batch and Group properties before starting a batch TrendManager Pro is also used to setup pre defined messages for mark on chart setup of the Email Alarm System Event Batch Markers Counters Control and periodic Totaliser reset TrendManager Suite Batch Report Tool see Batch Report Tool The Batch Report Tool allows the user to quickly adjust the parameters of the report to focus on the important data within the recorded batch information The Batch Report function is enabled via an unlock code which is entered the first time you go to run a Batch Report in the TrendManager So
17. codes will be supplied one for the TrendServer Pro software and one to register QOQ during the setup The CD based application generates customized IQOQ documentation for the specific recorder model and its associated options System requirement of 4GB SRAM for generating QOQ report The IQOQ report is documented evidence that the process will produce a consistent product that meets specification The QOQ report that is generated is Honeywell s documentation package that provides verification that all aspects of the recorder installation adhere to Honeywell s recommendations appropriate safety codes and approved company specifications and design intentions The output is a PDF report containing the full configuration details of the recorder This provides the user with the ability to demonstrate that they have standard operating procedures for operator training written methods for the verification of the calibration of the system elements and upkeep of the system Access control and traceability The password system supports five levels of users and eight areas of access with ability to password protect functions within these areas Graphing Folders Recorders Database Server Import Communications and Settings etc Up to 50 Users can be registered All modifications and access are recorded in the Audit manager A System Status window which can be hidden provides status information concerning communications 10 Commun
18. d 0 Messages Cp 502 Opened Connecti 1 Sp 52 Last Status 0 Dp 22 Last Status Time No Erros EP 26 n Op 160 Client connections Database logging Diagnostics 26 A Figure 1 5 Communications Server User Interface TrendView Historian PC software that extracts data from TrendManager Suite databases and communicateswith various OPC HDA Clients e g Matrikon to analyze the Historical data of recorder A separate unlock code is required to activate this software TrendManager Suite installation is mandatory when using Trendview Historian Trendview Historian function uses OPC HDA to acquire the data refer to 43 TV 25 41 Trendview Historian User Guide A Windows based Client application is be used to view and access historical data from Trendview OPC Historian Server TrendManager Suite 13 Database Management Tool The Database Management Tool is an offline separate software application that is supplied with the TrendServer software It uses a tree structure to view data files in TrendManager database folders as well as files on the PC hard drive The data files can be viewed and managed by Devices all data for one recorder or by Monthly Archives one month s worth of data Using the Database Tool portions as well as entire databases can be copied archived moved or deleted Colour coded highlights of data files shown in Green Purple and Yellow in Figure 1 6 on page 13 are used to show if data is being stored
19. d Print format TrendManager Suite Sales and Service For application assistance current specifications pricing or name of the nearest Authorized Distributor contact one of the offices below ASIA PACIFIC Honeywell Process Solutions TAC hfs tac support honeywell com Australia Honeywell Limited Phone 61 7 3846 1255 FAX 61 7 3840 6481 Toll Free 1300 36 39 36 Toll Free Fax 1300 36 04 70 China PRC Shanghai Honeywell China Inc Phone 86 21 5257 4568 Fax 86 21 6237 2826 Singapore Honeywell Pte Ltd Phone 65 6580 3278 Fax 65 6445 3033 South Korea Honeywell Korea Co Ltd Phone 822 799 6114 Fax 822 792 9015 EMEA Honeywell Process Solutions Phone 80012026455 or 44 0 1344 656000 Email Sales FP Sales Apps Honeywell com or TAC hfs tac support honeywell com AMERICA S Honeywell Process Solutions Phone TAC 1 800 423 9883 or 215 641 3610 Sales 1 800 343 0228 Email Sales FP Sales Apps Honeywell com or TAC hfs tac support honeywell com Specifications are subject to change without notice TrendManager Pro Suite is a registered trademark of Honeywell International Inc For more information To learn more about Paperless Recorders visit www honeywellprocess com Or contact your Honeywell Account Manager Process Solutions Honeywell 1250 W Sam Houston Pkwy S Houston TX 77042 Honeywell Control Systems Ltd Honey
20. dbus RTU slave mode via an RS485 port USB ports allow the use of an AS CIl barcode reader For FTP communications and setup Ethernet port TCP IP stack installed Fixed IP addresses for all connected transfer recorders For Real time communications Ethernet port RS485 to RS232 adaptor TCP IP stack installed Fixed IP addresses for all connected PCs and recorders For Database Management Tool Same as TrendServer Pro Microsoft NET framework needs to be installed Use with TrendManager software version 5 0 3 24 or higher Batch Mode Available with TrendManager Pro and TrendServer Pro only Use with TrendManager Server Pro software version 5 0 4 0 or higher Trend Server Pro deployment diagram Maintenance Dept Quality Dept Trend Server Pro Thiri narty Trend Server P ro Client Trend Server P ro Client Client OPC Clients Plant Wide Local Area H etwork Trend S erver Pro Server Ethernet Local Instrument H etwork GR Series Recorder X Series Recorder V5 Series Recorder Modbus slave device Figure 1 8 TrendServer Pro Deployment TrendManager Suite Features Display and print time scales From 3 5 ms cm to 1 15 month cm Data format Honeywell proprietary binary encryption Protocol used for Recorder Communications TrendServer Software utilizes the Honeywell Trendbus communication protocol for real time network communications with the V5 recorders The
21. e of file structures or recall of cryptic file names Saving and organizing graphs Once a particular graph has been setup it can be saved When reopened it will display all the data including any data imported while the graph was closed Graphs can be saved and organized in graph folders Multiple Trends data from different sources can be displayed and reviewed together on the same graph multiple graphs can show the same trend with different scale zooms and time spans User Added Comments User comments can be added to the data on any graph to aid in understanding any particular point of interest these are embedded with the data and cannot be modified X Series TMP or higher or erased once the graph has been saved A User Added Comment Block is shown here Export Data supports the exporting of data to other third party spreadsheet like Microsoft Excel or Lotus 123 packages data can also be emailed Exported as multiple spreadsheets or as a single spread sheet Event Batch Viewer All the alarms events markers status messages etc are displayed on the graph with the measurement data or on a tabular view with time and date stamps Event Batch details are displayed in the Event Batch Viewer Recorder Setup management TrendManager Pro allows the creation archiving up to 26 setups per recorder printing copying of Honeywell V4 V5 X Series and GR Series paperless recorders setups thus providing traceability
22. ftware Individual batch data can be displayed in the Event Batch Viewer AMS2750 TrendManager and TrendServer B Thu 03 Mar 2005 06 06 40 Thu 03 Mar 2005 06 07 57 Z Thu 03 Mar 2005 06 11 54 AE Thu 03 Mar 2005 06 15 45 OD Thu 03 Mar 2005 06 17 55 E Thu 03 Mar 2005 06 23 48 TrendManager Pro graphs all the data and any events Double click on a Start batch icon in the Event bar to produce an individual batch graph Thu 03 Mar 2005 06 06 40 Wed 02 Mar 2005 23 43 20 Wed 02 Mar 2005 09 09 47 Wed 02 Mar 2005 09 04 54 Wed 02 Mar 2005 09 02 49 Wed 02 Mar 2005 09 02 06 Wed 02 Mar 2005 09 01 06 Wed 02 Mar 2005 08 59 06 Wed 02 Mar 2005 08 52 28 Wed 02 Mar 2005 08 35 48 Wed 02 Mar 2005 08 19 08 Wed 02 Mar 2005 08 02 28 FIGURE 1 3 Graphing Batches Thu 03 Mar 2005 06 23 48 Thu 03 Mar 2005 00 00 44 Wed 02 Mar 2005 23 43 20 Wed 02 Mar 2005 09 06 35 Wed 02 Mar 2005 09 04 54 Wed 02 Mar 2005 09 02 31 Wed 02 Mar 2005 09 02 06 Wed 02 Mar 2005 09 01 06 Wed 02 Mar 2005 03 59 06 Wed 02 Mar 2005 08 49 17 Wed 02 Mar 2005 08 32 37 Wed 02 Mar 2005 08 15 57 Added Tue Mar 08 2005 15 04 50 Start Old Data New Batch Added Tue Mar 08 2005 15 05 37 User ID Add User ID June Added Tue Mar 08 2005 15 05 56 Comment Add a Comment Added Tue Mar 08 2005 15 06 49 Pause add in other Events Added Wed Mar 09 2005 14 53 18 Resume resume Added
23. ications with recorders TrendServer Pro is used to manage communications with the recorders and other network connected devices this includes uploading set ups over the communications link file transfers manually or with the FTP scheduler or collecting data in real time using the integral Communications Server It gives you a complete view of process and real time data on your PC A separate modbus configuration tool is used to quickly setup communications between Trend Server Pro and other Modbus RTU compatible devices FTP and real time communications to the same database are not supported and that doing time synchronisation both by FTP and by real time is not recommended The X Series and GR Series recorders use the Modbus comms protocol which does not support retrieving event data in Realtime or buffered Logged data The Modbus Comms Protocol only supports getting real time analog data from the recorders and other network connected devices Sharing data over the Network TrendServer Pro allows accessing to the databases remotely on any PC that is also running TrendServer and is connected to the same Local Area Network This allows the user to share data over the network and to perform such functions as e Logging real time data on two different PCs simultaneously e Sending the data from the recorder real time to one PC and by FTP at given times to another PC Secure Comms available on the GR Series recorders e Accessing
24. lays the currently imported data along with the associated events Only data from a single recorder can be imported A tabular listing of the data is not available in TrendViewer this is a TrendManager Pro function TrendViewer is supplied with each recorder and no unlock code is required to install it TrendManager Pro Features TrendManager Pro includes all the features of the TrendViewer software plus it supports the configuration of the Honeywell TrendView paperless recorders analysis of the data and the exporting of data to other third party spreadsheet like Microsoft Excel or Lotus 123 packages e Import of data in the local databases via removable media TrendManager Pro allows for the importing of data from a variety of devices Minitrend Multitrend and eZtrend recorders Minitrend V5 Multitrend Plus V5 eZtrend V5 Circitrend V5 Teletrend V5 Multitrend V5 and V4 recorders Also VRX Recorders DPR180 250 UMC800 HC900 with data storage These Honeywell devices including actuators DR4500 DR4300 Circular Chart Recorders DPR100 Strip Chart Recorders and UDC Controllers have Realtime capabilities When imported the new data is automatically recognized and stored in the correct place in a secure database Remembering file names or labelling the storage media is not necessary The recorders or pen data from the recorder can be dragged into the graph window for viewing Reviewing of the data files does not require knowledg
25. lick in this area 8 Data Locator Gives you a quick view of where the recorded data is represented as a grey bar 9 Scale area is the area that displays all of the pen scales these can be arranged expanded and moved to provide for the best viewing Dragging a scale to the trash can removes the trend from the display without affecting the stored data 10 Option switches zone several display options are performed in this area 11 Point markers show the actual logged values with black dots 12 Print button prints the graph on the default printer 13 Export Button exports the data on the graph to excel or CSV Comma Separated Variables format 14 Clock button Defines the data to be displayed on the graph a Graph Set Time Span display menu shown here appears Go to last can be used to display automatically the last period of recorded data for the duration 1 min 5 min 15 min 30 min 1 hr 2 hr 6 hr 12 hr 1 day 5 days or 7 days TrendManager Suite 8 15 Graph pen Source data This will provide information like PenName Pen Type RecorderName DatabaseName ServerName 16 Save graph Select to Save the current graph 17 Delete graph Drag and drop to delete graph TrendManager Server Updated Features TMP software release 13 onwards and Recorder Firmware EP onwards Batch Mode The Batch Mode facility comes as standard with TrendManager Pro and TrendServer Pro version 5 0 4 0 and later Batch Mode enhance
26. ly Source Location From Directory From Network FTP Henry 160 221 36 29 v Setup Batch Schedule General options IV Auto graph the data I Make a log file in the program directory r X Series FTP options Connection speed Fast gt 5 mbps Fast gt 5 mbps Medium 1 mbps 5 mbps TrendV iew V5 FTP optiong Slow lt 1 mbps Download from Disk drive C PC Card I Delete data on recorder on successful completion NOTE Hit F1 for help on using FTP The FTP Scheduler downloads the data automatically from the media storage of the recorders and stores them in a database based on specified days and time The data acquisition rates are the ones specified in the setup of the recorder FTP transfer is protected and secure the files in the recorder cannot be accessed by any other application other than Trend Server Pro FTP now has a Find Device facility for X Series and GR Series recorders using the recorder s network serial number to locate the device Schedule settings Description Destination database Schedule 1 Local Server Initial Database Select Select the recorders you wish to add to the download from the left list and add them to the right Available Recorders Recorder Name IP Address Add Hox xs 100076 RR Remove Remove All Recorders to download from _ IP Address 192 168 1 3 Select when to perform the download Download from 5 only C Single Shot Disk drive PC Ca
27. ncurrent Batch Mode v Export using CSV format files v Enable Fuzzy Logging v Events system including user counters and reports v AMS2750 survey setup v Password protection Full user traceability Export using OPC links Communicate with recorders using RS485 interface Communicate with recorders using Ethernet TCP IP Distribute all recorder data over LAN plant wide FTP or Secure Communication Interface over Ethernet Web browse a recorder Send setup to recorder via Ethernet Export using OPC links Audit trail manager Relating data retrieval used for graphing amp logging Replay of historical and Realtime data using a split screen format Enable Modbus and Modbus X via Ethernet or RS485 Comms Server manages the communication status of the recorder Remote access to other servers via Ethernet Modbus Master and Communication with slave over RS485 or Ethernet IQOQ Protocol Documentation option with TSP only View Archived Databases NNS SSIS ISOON N NII SSIES OSG IST I SIINI SII SII NII N II SII NI SIS RS485 is available as an option on the eZtrend QXe not featured on the X Series and GR Series Recorders TrendManager Suite Features TrendViewer Features TrendViewer provides the ability to view and print the graph data that has been imported from the recorder s removable storage media It provides a graph screen that disp
28. nising the clock on the recorder with a Network Server Or a recorder can be enabled as a server other recorders set up as clients can synchronise their time to the server recorder Min time period between checking and updating the time is 600 seconds Software License Users Available as a Single or Five User license the license is based on the number of PC s the software is installed on not the number of users using a particular PC with the software installed on it Data Import Capability Provides ability to import data files from many Honeywell Recorders see Trend Manager Pro Features on page 4 Databases Databases can be local on same PC as TrendManager Suite remote on different PC allows the data to be available to other Trend Server Pro users Password TrendManager Suite Five levels of users Guest or Default User Basic User Standard User Power User or Administrator Eight area of access with ability to password protect functions within these areas Graphing Folders Recorders Database Server Import Communications and Settings 50 Users with their own password allowed Audit Manager Available on TrendServer Pro and is accessed through the password system at the Administrator level allows the Administrator to configure log and view all actions that have occurred within the software Printing Network printing of graphs using either a Standard Print format or Legen
29. ption on the eZtrend recorder e Recorder Set up TrendManager Pro can be used to set up and configure a Honeywell TrendView recorder s from the PC Parameters can be set as part of the configuration These include General Set up information e g Recorder Name Description Recorder ID and Serial Number which is used throughout the software for identification purposes e Field lO Analog Inputs can be configured for type and range along with a label and any signal conditioning that may be required Analogue Out Pulse In Alarm Digital IO are configured by selection of the appropriate menu button on the left Linearisation tables can be set up to allow non linear input signals to be displayed on the recorder e Pen Set ups Include Scaling information engineering units colour and thickness of trends logging types and rates math calculation totalisation set up and alarm types and levels and Rolling Average A pen or input setup can be copied instantly by dragging and dropping the pen or input icon TrendManager Suite 6 General Pens Groups Batch Credits Printer Error Alert Name OX 05 Description Honeywell X Series 19 Serial No 100076 Recording Media Life Calculations These values are basec on the current devices pen logging setup Transfer Fuzzy logging is considered to be half the logging rate of a continuous pen at the same logging rate artware Select memory 64MB 7 Approximate time to fill 64MB
30. rd C Interval Delete files on recorder Selected Days Receipt in log file IV Time I Synchronise recorder clock with PC V5 only 17 43 54 X Series only Connection speed Fast gt 5 mbps X P ays P nws P Days of the week I Sunday M Monday M Tuesday M Wednesday V Thursday M Friday D Saturday OK Cancel Figure 1 7 FTP Scheduler Use the FTP Scheduler to transfer recorder setups and data at specified times TrendManager Suite 15 Specification System requirements PC Operating System Supports Microsoft Operates in Window 7 32 and 64 bit Professional See Deployment diagram below Enterprise and Ultimate Edition Windows Server 2008 Windows 8 and Windows Server 2012 PC System TrendViewer 1 GHz Pentium processor or higher with a mouse CD ROM drive Monitor screen resolution 1024 x 768 minimum requirement high colour 512 Mbyte of RAM 50Mbyte free hard disk space 16 colour graphics 24 bit recommended Screen Designer only Flash card reader or USB port for X Series recorders 3 5 floppy disk drive or PCMCIA for V5 recorders PC System TrendManager or As for TrendViewer but with 2 Gbyte Hard drive free disk space TCP IP TrendServer installed System requirement of 4GB SRAM for generating IQOQ report V5 For RS 485 communications RS 485 or RS 232 port with adapter V5 X Series Communications Modbus TCP IP slave mode web over Ethernet DHCP standard communications port Mo
31. s the management of data collected in non continuous processes so called batch processing such as thermal treatment sterilisation food processing chemical reactions etc Concurrent batches can be set up in the recorder and are associated with a group of pens The pens with in each group will belong to the batch that is controlled by that group Batches can be controlled through the event system and batch markers are setup by the user and are used to identify and analyse batches of data Supports up to 6 concurrent batches Batch features include Pause chart when batch stopped Batch Logging control List driven data fields Automated batch counters Event driven batch control Updated control and feedback Batch mode State and Count in scripts embedded variables On the recorder command lines to Start End Pause Resume or Abort a batch are logged via the Batch Control menu by using the touch screen a USB keyboard or a barcode reader Other Batch markers can be added such as a Description User ID Comments Lot Number X Series only The data is then collected by the usual means media disk or card FTP real time communications and processed in Trend Manager Server Pro software Once imported the batch identifiers are listed in a dedicated window Batches can be sorted filtered searched by keywords or numbers Selecting a batch automatically opens a graph containing all the pen data and all events relative to this batch The gr
32. the data stored on a server from other PCs TrendServer must be installed on the client PCs multiple licenses available e Installing the Communication Server and the Database on a central backed up server with an uninterrupted power supply to provide added security of the data TrendManager Suite 11 Recorders x d Add New Recorder R 2222 Oven 1 E 0666 Recorder AIAN atl ite a CS e hamsii aaas 0118 Events test 0109 Rogers Recor E 0000 Digital VO Te D x Series Device Na Mini ax E Minitrend QX MO Turbine 1 Station 1 Li LETH A T g AURA AAAA 2 U 10 15 20 25 30 min 2006 Mon Apr 03 09 00 T x Mon Apr 03 09 22 23 A device has been updated 160 221 36 107 z Mon Apr 03 09 22 23 A device has been updated 160 221 36 107 Mon Apr 03 09 22 24 A device has been updated 160 221 36 107 6 Mon Apr 03 09 22 24 A device has been updated 160 221 36 107 Mon Apr 03 09 22 50 New data has been imported 160 221 36 107 Press F1 for Help Figure 1 4 Interface Areas TrendServer Pro provides the ability to view real time data 1 together with historical data 2 These windows can be expanded or collapsed by dragging the viewing area to the right or left depending on what is most important to the user Scale indicators 3 for each of the pens are available for viewing at the same time These can be expanded and
33. to a different location other than the local databases This allows data to be stored to a secure server that is backed up on a routine basis The data is still accessible with TrendManager Pro or TrendServer Pro just as if it was still located on the local PC The Tabbed Window at the bottom of the Database Management Tool window provides a summary of operations or an Audit Trail of actions performed during each session There is an XML archive tool that can be used to export a local database as XML The device folder created can contain a Device Event and Logged pen information in schema format lT Database Tool File Delete Copy Move Help C Program Files TrendManager Suite TMP5DB E Initial Database l 50V divider Devices Al board tests V5 H Archives E Anderson avamalware data storage amp functionality requirements 2 Database archive Database tool copy dun 06 Set Destination Path at FP Jul 06 fy Aug 06 Archive Delete Delete g ia Sep 06 ep Ha June FTP Ez Ma Oct 06 i Saved Data oser ty Nov 06 ti Andy FTP Initial Database Junes 2 CI DATOOO2 5 Add DBS Initial Database 2 CP 0001 Henry 2 Phase Gates Star Team unused docs Board Test Procedures E a Bob V5 orcad drawings wip C CD IMAGE Change contol 2 ConferenceRoom 2 Current Documentation w DFSS F docs Draw Out Recorder C R Op Count 06 06 2007 10 09 04 C Program Files TrendMa H Ringwood
34. well House Skimped Hill Lane Bracknell England RG12 1EB Shanghai City Centre 100 Jungi Road Shanghai China 20061 43 TV 03 09 June 2014 www honeywellprocess com 2014 Honeywell International Inc Honeywell