1. 3 Smart Energy Plug in Switch Z Wave Series Features Adopt Z Wave protocol to secure the success of wireless two way communication Higher RF output power 2 5dBm output power as compared to 2 5dBm 300 series Z wave module to enhance the communication range With zero crossing technology to extend the number of switching Easy install Very low Electricity consumption Resistive load 3000W 1500W for incandescent load or 320W for fluorescent load Overload protection Auto report the state when manually push the ON OFF button Auto report the wattage when variation over 5 Voltage Current Power factor Instant power Wattage and Accumulated power consumption KWh report Z Wave V6 02 Z Wave Certificated PAN11 1 ZC08 13020005 PAN11 2 ZC08 13020006 PAN11 3 ZC08 13020007 LVD EN 61058 R amp TTE EN 301489 EN 300200 Introduction This smart energy plug in switch is a transceiver which is a Z Wave enabled device and is fully compatible with any Z Wave enabled network Z Wave enabled devices displaying the Z Wave logo can also be used with it regardless of the manufacturer and ours can also be used in other manufacturer s Z Wave enabled networks Remote On Off control of the connected load is possible with other manufacturer s Wireless Controller Each switch is designed to act as a repeater Repeaters will re transmit the RF signal to ensure that the signal is received by its intended dest
2. N11 3 57 7x94 5x61 mm Application Home Automation Philio Technology Corporation Energy Saving oe www philio tech com Firmware Version 1 1 Quick Start This device is a Z Wave Actor Tripple click the button on the device confirms the inclusion exclusion and association After plugging in it will stay in auto inclusion mode for 4 minutes Please refer to the chapters below for detailed information about all aspects of the products usage What is Z Wave This device is equipped with wireless communication complying to the Z Wave standard Z Wave is the international standard for wireless communication in smart homes and buildings It is using the frequency of 868 42 MHz to realize a very stable and secure communication Each message is reconfirmed two way communication and every mains powered node can act as a repeater for other nodes meshed network in case the receiver is not in direct wireless range of the transmitter Z Wave differentiates between Controllers and Slaves Slaves are either sensors S transmitting metered or measured data or actuators A capable to execute an action Controllers are either static mains powered controllers C also referred to as gateways or mobile battery operated remote controls R This results in a number of possible communication patterns within a Z Wave network that are partly or completely supported by a specific device Controllers control actuators r i Actuators report change
3. Please read carefully the enclosed user manual before installation of the radio actuator in order to ensure an error free functioning ATTENTION only authorized technicians under consideration of the country specific installation guidelines norms may do works with 230 Volt mains power Prior to the assembly of the product the voltage network has to be switched off and ensured against re switching The product is permitted only for proper use as specified in the user manual Any kind of guarantee claim has to be forfeited if changes modifications or painting are undertaken The product must be checked for damages immediately after unpacking In the case of damages the product must not be operated in any case If a danger free operation of the equipment cannot be assured the voltage supply has to be interrupted immediately and the equipment has to be protected from unintended operation Installation Guidelines On off knob LED indicator In the front casing there is an On Off button with LED indicator which is used to toggle switch on and off or carry out inclusion exclusion reset or association When first powered the LED flashes on and off alternately at a 2 seconds interval It implies that it is not included in a Z Wave network and has not been assigned a node ID Auto Inclusion The auto inclusion starts when the switch is not included into a Z Wave network and plugged into a wall outlet Auto inclusion timeout is 4 minutes during the no
4. are disposed of in landfills or dumps hazardous substances can leak into the groundwater and get into the food chain damaging your health and well being
5. de information frame will be emitted once every 5 seconds Unlike the normal inclusion it is not necessary pressing the On Off button on the switch If auto inclusion exceeds the timeout you have to include the device manually Note Do not locate the switch facing direct sunlight humid or dusty places The suitable ambient temperature for the switch is 0 C 40 C Do not locate the switch near to combustible substances or any source of heat After putting it into use the casing of the switch will become a little bit warm Behavior within the Z Wave network 1 On factory default the device does not belong to any Z Wave network The device needs to join an existing wireless network to communicate with the devices of this network This process is called Inclusion Devices can also leave a network This process is called Exclusion Both processes are initiated by the primary controller of the Z Wave network This controller will be turned into exclusion respective inclusion mode Please refer to your primary controllers manual on how to turn your controller into inclusion or exclusion mode Only if the primary controller is in inclusion or exclusion mode this device can join or leave the network Leaving the network i e being excluded sets the device back to factory default If the device already belongs to a network follow the exclusion process before including it in your network Otherwise inclusion of this device will fail If the controller be
6. ination by routing the signal around obstacles and radio dead spots This smart energy plug in switch is able to detect voltage current power factor Instant power wattage 5 3150W and overload wattage 3010 3300W of connected light or appliances When detecting overload state the Module will be disabled and its On Off button will be lockout of which LED will flash quickly for 30 seconds However unplug and re connect the Module will reset its overload condition to normal status This plug in switch can active sent out instant power wattage when variation over 5 or active sent out state change when manually push the ON OFF button this allows the controller to avoid polling the reading wattage value and state of the switch and can increase the efficiency of controller Specification No load standby power 0 48W 230V Input voltage 90 240VAC RE Repl 868 42 EU MHz RE Reiter FCC part15 249 EN300 220 1 Distance min 30m indoor min 100m outdoor weight 118g Mechanical Dimension W x H x D 57 7x94 5x76 6 mm Germany type PAN11 1 Operation Temperature 0 40 C Resistive load Load incandescent load fluorescent load load return error rate 5W 40W load return error rate40W 3150W overload PAN11 1 2 3 Dimension and Placement unit mm Germany type PAN11 1 57 7x94 5x76 6 mm France type PAN11 2 57 x94 5x76 6 mm UK type PA
7. ing included was a primary controller it has to be reset first Tripple Click the button on the device confirms inclusion and exclusion After plugging in it will stay in auto inclusion mode for 4 minutes Operating the device Manual Operation e Plug the device into a wall outlet near the load to be controlled Plug the load into the switch Make sure the load to be controlled cannot exceed 3000 watts e Press the button or switch the load to the ON position To manually turn ON the switch press and release the On Off button The LED will turn on and the load plugged into the switch will also turn on To manually turn OFF the switch simply press and release the On Off button again The LED will turn off and the load plugged into the switch will also turn off Remote Operation Remote On Off control of the switch is possible with any manufacturer s Z Wave controller Further you can set associations to let your device controlled by other Z Wave devices Like sensors The switch is able to detect the current wattage 5 3150W and overload wattage 3010 3300W of connected ligths or appliances When detecting overload state the switch will be disabled and its On off button will be locked and the LED will flash quickly However unplug and reconnect the switch to reset its overload condition to normal status Node Information Frame The Node Information Frame is the business card of a Z Wave device It contains information about the device
8. of status back to controller t a a Sensors report change of status of measured values to controller Sensors directly control actuators Actuators control other actuators 3 2 Remote controls send signals to static controllers to trigger scenes or other actions Remote controls control other actuators c 6 There are two different role a controller can have There is always one single primary controller that is managing the network and including excluding devices The controller may have other functions like control buttons as well All other controllers don t manage the network itself but can control other devices They are called secondary controllers The image also shows that its not possible to operate a sensor just from a remote control Sensors only communicate with static controllers NOU BKRWNE Product description The PAN11 is a Plug in switch which can be placed between a wall outlet for Schuko plug and electric devices with a resistive load up to 3000W plugged in by cord In addition this intelligent plug in switch is able to detect the voltage the power factor the current amd measure the electric power taken by this load in Wh as well as meter the electrical energy consumed in kWh It will also detect a possible overload 3010 3300W of the connected electrical device When detecting an overload the module is deactivated and the LED will flash for 30 seconds Before Device is installed
9. r to 200 it may be needed to set a value of 200 minus 256 minus 56 In case of two byte value the same logic applies Values greater than 32768 may needed to be given as negative values too Watt Meter Report Period Parameter Number 1 Parameter Size 2 If the setting is configured for 1hour set value 720 the PAN11 will report its instant power consumption every 1 hour to Z Wave Controller Unit 5 seconds 720 5s 3600s 1 hour Default 720 KWH Meter Report Period Parameter Number 2 Parameter Size 2 If the setting is configured for 1hour set value 6 the PAN11 will report its Accumulated Power Consumption KW h every hour to Z Wave Controller Unit 10min 1 52767 6 10min 1hour Default 6 Threshold of Watt for Load caution Parameter Number 3 Parameter Size 2 This is a warning when the wattage of load over the preset threshold value if the load wattage exceeds the setting value the PAN11 will send a warning alarm command to the controller 10 3000 wattage threshold value Default 3000 Threshold of KWh for Load caution Parameter Number 4 Parameter Size 2 This is a warning when the KWh of load over the preset threshold value if the Accumulated Power Consumption exceeds the setting value the PAN11 will send a warning alarm command to the controller 1 10000 KWh threshold value Default 10000 Command Classes Supported Command Classes e Basic version 1 e Binary Switch version 1 e Ver
10. sion version 1 e All Switch version 1 e Manufacturer Specific version 2 e Configuration version 1 e Meter version 3 e Association version 1 Technical Data Explanation of Z Wave specific terms e Controller is a Z Wave device with capabilities to manage the network Controllers are typically Gateways Remote Controls or battery operated wall controllers e Slave is a Z Wave device without capabilities to manage the network Slaves can be sensors actuators and even remote controls e Primary Controller is the central organizer of the network It must be a controller There can be only one primary controller in a Z Wave network e Inclusion isthe process of bringing new Z Wave devices into a network e Exclusion is the process of removing Z Wave devices from the network e Association isacontrol relationship between a controlling device and a controlled device e Wakeup Notification isa special wireless message issued by a Z Wave device to annonces that is is able to communicate e Node Information Frame is a special wireless message issued by a Z Wave device to announce its capabilities and functions Disposal Guidelines The product does not contain hazardous chemicals Do not dispose of electrical appliances as unsorted municipal waste use separate collection facilities Contact your local government for information regarding the collection systems available If electrical appliances
11. type and the technical capabilities The inclusion and exclusion of the device is confirmed by sending out a Node Information Frame Beside this it may be needed for certain network operations to send out a Node Information Frame Tripple click the button on the device sends out a Node Information Frame Associations Z Wave devices control other Z Wave devices The relationship between one device controlling another device is called association In order to control a different device the controlling device needs to maintain a List of devices that will receive controlling commands These lists are called association groups and they are always related to certain events e g button pressed sensor triggers In case the event happens all devices stored in the respective association group will receive acommon wireless command Association Groups When the power consumption of load vary over 5 the PAN11 will send a Meter Report When on or off state has been changed it will send Binary Switch Report max nodes in group 1 Configuration Parameters Z Wave products are supposed to work out of the box after inclusion however certain configuration can adapt the function better to user needs or unlock further enhanced features IMPORTANT Controllers may only allow to configure signed values In order to set values in the range 128 255 the value sent in the application shall be the desired value minus 256 For example to set a paramete