Home

ABE25KX and ABD25KX Preliminary USER MANUAL

image

Contents

1. 0d00 disabled Be alarm is disabled 1 cmd 7E FF 02 06 10 14 7F reply 7E FF 84 06 10 01 2C BF 7F Get Power 7E FF 02 Query device for Update PS Voltage VV VV PS voltage in 10x Power 0x0064 0d100 10 0V 2 Supply Voltage 06 10 14 power supply voltage TE FF 84 17 FF PP V ZZ CRC cmd 7E FF 02 06 10 14 7F TF PP ZZ 7F reply 7E FF 84 06 10 00 63 F1 7F Power 0x0063 0d99 9 9V Page 22 of 23 ABE25KX and ABD25KX User Manual Packet Cottard format Explanation Possible replies Interpretation Examples 1 cmd 7E FF 02 06 11 15 7F reply 7E FF 84 06 TE FF 02 Query device for Update PS Current 2 11 00 AD 3E 7F Power 0x00AD 0d173 of eee 061115 power supply TE FF 84 06 11 PP PP ene pi bie 173A 2 cmd 7E FF 02 06 11 15 7F reply 7E PPY 7F current ZZ 7F i i FF 84 06 11 00 97 04 7F Power 0x0097 0d151 15 1A TE FF 02 Update Mute Status MM Mute status 0 1 md 7E FF 02 06 01 05 7F reply 7E FF 84 06 Query device for ae 01 00 00 83 7F Device is enabled 2 cmd 7E FF Get Mute Status 06 01 05 TE FF 84 06 01 00 MM enabled 1 muted mute status 02 06 01 05 7F reply 7E FF 84 06 01 00 01 82 7F 7F ZZ 7F ZZ CRC oe Device is muted 1 cmd 7E FF 02 03 04 05 7F reply 7E FF 84 03 Get Device fs a y z Query for device aE 84 03 XX Device address 04 00 0A 89 7F Device address 0xA 2 cmd Address JF address 0
2. 78 VDC or 80 and 240 VAC and consumes less than 190W KEY FEATURES e 13 75 14 50 GHz e 950 to 1 700 MHz e Smallest package size and weight e Double L O electronically and manually switchable 12 80 and 13 05GHz e Auto ranging 36 58 VDC or 80 240 VAC power options e Low power consumption e Digital temperature compensation e L O lock and amplifier LED e M amp C combined RS 232 485 FSK standard e Three year warranty e RoHS compliant ABE25KX 25W Ku Band BUC monitors and controls numerous parameters and has features that make installation and use of the BUC simpler and enhance system performance Page 4 of 23 ABE25KX and ABD25KX User Manual Receiving and Inspection The block up converter is designed to function outdoors and will arrive in a standard shipping container Immediately upon receipt of the block up converter check the packing slip against the actual equipment you have received Inspect the shipping containers exteriors for visible damage incurred during shipping CAUTION Handle the block up converter with extreme care Excessive shock may damage block up converter s delicate internal components Using the supplied packing list verify that all items have been received and undamaged during shipment Verify that all items are complete If there are any omissions or evidence of improper packaging please notify Actox Corporation immediately Equipment Damage or Loss Actox Corporation
3. converter to Actox Corporation after RMA number has been issued Out of Warranty Repair A non warranty and out of warranty repair service is available from Actox Corporation for a nominal charge The customer is responsible for paying the cost of shipping the BUC both to and from Actox Corporation for these repairs Page 19 of 23 ABE25KX and ABD25KX User Manual Appendix 1 Mechanical Drawing Coming Soon Page 20 of 23 ABE25KX and ABD25KX User Manual Appendix 2 Spare Parts The following sheet can be copied and used as a fax form to order the required spare parts Please make sure to include all identifying information to facilitate the processing of your order The order may be sent via email to the following address Fax 1 866 888 6087 Email mark_moore actox com For additional information please contact our customer service department at 619 906 8893 or 1 866 888 6087 Actox Corporation designers and manufacturers of telecom amp wireless products ABD25KX ABE25KX Ext Ku Band BUC Telephone Part Description Part Number Quantity Unit Line Price Total Fax to Customer Service 1 866 888 6087 Page 21 of 23 Appendix 3 ACK Acknowledge NACK Not Acknowledge TE FX EO ZZ 7F TE FX F1 YY ZZ 7F ABE25KX and ABD25KX User Manual M amp C Commands 1 reply 7E FF E0 E0 7F ACK reply sent from the BUC Acknowledge that the received packet was pr
4. device for Update Output PP PP Output power in 10 Power 0x012C 0d300 30 0dBm 2 Power 17 FF current output power Power 7E FF 84 17 x dBm ZZ CRC cmd 7E FF 02 17 FF EA 7F EA 7F FF PP PP ZZ 7F reply 7E FF 84 17 FF 01 A0 CD 7F Power 0x01A0 0d416 41 6dBm Query device for 1 cmd 7E FF 02 18 FF E5 7F reply 7E 7E FF 02 current gain Note Update Gain 7E FF Site ae FF 84 18 FF 02 8A 69 7F Gain 0x028A GG GG Gain in 10 x dB bs Get Gain 18 FF E4 value is depending of 84 18 FF GG GG ZZ 7Z CRC 0d650 65 0dB 2 cmd 7E FF 02 18 TF attenuation settings TF FF E5 7F reply 7E FF 84 18 FF 01 F9 F7 7F Gain 0x01F9 0d505 50 5dB 1 cmd 7E FF 02 18 FE E4 7F reply 7E FF 84 18 FE 00 C8 AA 7F TE FF 02 Query device for Update Attenuation AA AA Attenuation in 10 Atten 0x00C8 0d200 20 0dB 2 Get Attenuation 18 FE E4 current attenuation TE FF 84 18 FE GG x dB ZZ CRC cmd 7E FF 02 18 FE E4 7F TF GG ZZ 7F reply 7E FF 84 18 FE 00 69 0B 7F Atten 0x0069 0d105 10 5dB 1 cmd 7E FF 02 10 10 02 7F reply 7E TT TT low power Ai Get Low Power TE FF 02 Query device for Update Low Power threshold in 10 x dBm ZZ PES nro ol AE 2B TF Thresh Alarm 10 1002 current low power Alarm Threshold CRC Note zero value 0x01AE 0d430 43 0dBm 2 cmd 7E Threshold 7F alarm threshold ee ere means low power alarm PF 02110 10 02 7Eireply 7E FF8410 70 TT ZZ 7F i 00 00 84 7F Thresh 0x0000
5. 4 00 Xx ZZ JF ZZ CRC TE FF 02 03 04 05 7F reply 7E FF 84 03 04 00 0E 8D 7F Device address 0xE Get Over 7E FF 02 Query device for Update ever XX Alarm state 0 bed 7E FE 02 00 02 Oe reply ae ree Temperature 00 02 00 over temperature temperature alarm no alarm 1 alarm 02 00 01 87 7F Over temp alarm is raised 2 Al JF alain TE FF 84 00 02 00 XX TZ CRC cmd 7E FF 02 00 02 00 7F reply 7E FF 84 00 02 EN ZZ TF i 00 00 86 7F Over temp alarm is clear TE FF 02 Update low power 5x Alan stares on 7E FE 02 00 05 07 7E teply 7E FF 8400 Get Low Power Query device for Sa 05 00 01 80 7F Low power alarm is raised 2 00 05 07 alarm 7E FF 84 00 05 no alarm 1 alarm Alarm low power alarm Z cmd 7E FF 0200 05 07 7F reply 7E FF 84 00 05 7F 00 XX ZZ 7F ZZ CRC A 00 00 81 7F Low power alarm is clear JE FF 02 Update summary XX Alarm state 0 1 cmd 7E FF 02 00 OF 0D 7F reply 7E FE 84 00 Get Summary Query device for an OF 00 01 8A 7F Summary alarm is raised 2 00 OF 0D alarm 7E FF 84 00 0F no alarm 1 alarm Alarm summary alarm cmd 7E FF 02 00 OF OD 7F reply 7E FF 84 00 OF 7F 00 XX ZZ 7F ZZ CRC i 00 00 8B 7F Summary alarm is clear Command Packet Explanation Possible Interpretation Examples format replies Set Mute TE FF 14 Mute Unmute the device ACK MM Mute control 1 1 cmd 7E FF 14 13 01 00 01 07 7F reply ACK Control 13 01 00 NACK Mute 0 enable Mute device 2 cmd 7E FF 14 13 01 00 00 06 MM Z
6. ABE25KX and ABD25KX User Manual Cit ABE25KX and ABD25KX 25 W P1dB Extended Ku Band BUC Preliminary USER MANUAL Page 1 of 23 ABE25KX and ABD25KX User Manual Table of contents PPEOCUC HOM kecctxcamcecetea ter sene ikon eu acsaroe te tok dels meante earns Receiving and inSpection 0 ccc ce eee eee eee eee eee eens e Equipment Damage or Loss e Return of Equipment Preparing for installation 0 cces cece cece cece eee eee reneeenens e Safety Precautions General AESCrlptlon injec niece esis ne ve we elew eed ete ee ke a wee ee eee eee e Considerations e Securing the Block Up Converter Installing the Block Up Converter 0 ccceeeceeeeeeeeseeeeeeeeeeeneeeeeenenes e LED Indicators Connector Pin Assignment 10Mhz Reference e Powering Options Setting L O Setting Tx Rx Frequencies Recommended Test Equipment ccecececeeeeeeeeneneeeeeeeeeeeeeeeeeenenes Technical Specifications ccc eee eee eee eee eee eee Assembly and Installation 0 0 cece eee eee eee ee eee e Connections and Mounting Hardware e Fan Outline Functional Overview cccceeceeeee eee eeeeeeeeeueeeueueeennnanes e General e IF RF Conversion and Amplification e Monitor and Control Operation Procegure i ccs ep duouiepeekesshchusawhtaedw pete deaencaveus Page 2 of 23 ABE25KX and ABD25KX User Manual Maintenance EEE E E ten E eee hat eee EE 18 e Prevent
7. C power source L Band signal enters the BUC by a coaxial cable converted to Ku Band by the BUC and goes through an internal isolator and reject filter which provides a good VSWR at the input and minimizes spurious on receive band 10 95 12 75GHz Under normal operation the RF amplifier will amplify the RF Input signal level up to a power level of 44 dBm 25 Watts CW P1dB minimum To achieve the rated output power of the RF Amplifier provide the necessary gain and low insertion loss The amplified signal is transmitted through the output waveguide section to a satellite up link system Monitor and Control standard The block up converter may have a RS 485 and RS 232 serial interface With this standard option the block up converter can communicate to the indoor unit or redundancy control block up converter via RS 485 or RS 232 The control system can provide the following M amp C functions BUC Alarm via RS 485 RS 232 when an input BUC within the block up converter system current draw is below 0 3A a BUC alarm signal will be transmitted via the RS 485 RS 232 serial interface Mute Control via RS 485 RS 232 Mute Control via hardware line TTL high level signal will mute a block up converter Output Power Monitoring 15 dB dynamic range via RS 485 RS 232 Base Plate Temperature Monitoring via RS 485 RS 232 Page 16 of 23 ABE25KX and ABD25KX User Manual Operation It shall be performed by authorized personnel pr
8. LNB and the Power supply to minimize the effects of antenna sway in strong winds Air movement across the heat fins is possible The fan of the BUC should be facing the ground when mounted The fan intake and exhausts are free from any obstruction The length of the Power supply cables is taken into consideration in determining the mounting location of the power supply Throughout installation and during any polarization azimuth or elevation adjustment ensure that cables and waveguide are not crimped or pinched Page 8 of 23 ABE25KX and ABD25KX User Manual LED Indication Orange L O 13 05GHz Green L O 12 80GHz Green Power OK Alarm SSPA OUT muted Not enough Red input Connectors Pin Assignment Connector Type Pin Signal Parameter _ IF Input 0 dBm max J1 IF IN N F type female 10 MHz Ref IN een J2 RF OUT WR 75 RF Output 46 0 dBm min MS3102A 10SL 4P Line In 80 240 VAC J3 AC POWER IN AC Use screw and 2 pin male B Common nuts for ground e f aon RS 485 Co reo 0 875 mV PT02E12 10P 027 E Detector 25W J4 M amp C Interface 10 pin male 1360 mV 25W e o P men Mues when Low o en ee k ro e Page 9 of 23 ABE25KX and ABD25KX User Manual NOTE 1OMHz Reference The BUC must receive a stable external 10MHz reference provided by a stable signal source such as a signal generator satellite modem or injected external
9. Verify the system is properly set up The power output at 1 dB compression shall be measured for evaluating the performance of the block up converter It is recommended to measure the following parameters for ensuring that the block up converter is in good working condition Gain and Gain flatness RF load VSWR and RF source VSWR Two Tone Inter modulation Distortion Return Loss at connectors of the block up converter Using a Source and an IF input signal level within the small signal region of the block up converter measure the power level at connectors IF or MS connector Plot the swept response on a test data sheet From the plot determine gain and gain flatness Plot the swept return loss for both the IF Input and RF Output signals on a test data sheet From the plot determine the return loss From the output power measurements determine P1dB Record value on a test data sheet Measure the Two tone Inter modulation Suppression using two equal signals separated by 5 MHz Record value on test data sheet WARNING Cable connection and disconnection shall be done carefully to avoid physical damage to the cables and connectors which may cause intermittent problems in the future Symptom Action Fails performance test Check power source RF source cabling and connectors Check LED indicators for status and if the light is red contact Actox Corporation If we are not able to assist you remotely return block up
10. Z 7F ZZ CRC 7F reply ACK Enable device Set Attenuation 7E FF 14 Set internal attenuator value ACK AA AA Attenuation 1 cmd 7E FF 14 18 FE 00 C8 3A 7F reply ACK 18 FEAA Note value is internally NACK in 10x dB ZZ CRC Set attenuator to 20 0dB 0d200 0x00C8 2 AA ZZ 7F rounded with 0 5dB discrete cmd 7E FF 14 18 FE 00 69 9B 7F reply ACK value range is 0 20 dB Set attenuator to 10 5 dB 0d105 0x0069 Set Low Power 7E FF 14 Set low power alarm threshold ACK TT TT Low power 1 cmd 7E FF 14 10 10 00 C8 DC 7F reply ACK Alarm 10 10 TT Note zero value means low NACK threshold in 10x dBm Set threshold to 43 0dB 0d430 0x01AE 2 Threshold TT ZZ 7F power alarm disabled ZZ CRC cmd 7E FF 14 10 10 00 00 14 7F reply ACK Set threshold to 0 0 dB 0d00 0x0000 alarm disabled Set Device TE FF 14 Set device address Note 0 lt ACK XX Device address 1 cmd 7E FF 14 03 04 00 0A 19 7F reply ACK Address 03 04 00 address lt OxE NACK ZZ CRC Set device address to OxA 2 cmd 7E FF 14 03 XX ZZ 7F 04 00 OE 1D 7F reply ACK Set device address to OxE Page 23 of 23
11. e and install the block up converter The specified humidity is up to 100 during operation However installation should be carried out in dry conditions free of salt spray or excessive humidity This will eliminate the possibility of moisture and other foreign substances from entering the output waveguide flange CAUTION Only authorized technical personnel should perform the Installation and proper electrical hookups of the block up converter The block up converter is designed to operate in an outdoor environment and is waterproof when mounted in the correct orientation The block up converter contains high flow rate fans 24 CFM for cooling the block up converter These fans function continuously during the operation To provide a sufficient airflow the block up converter should be mounted with a minimum clearance of 3 inches on all four sides and the bottom Adequate cooling for the block up converter will provide years of top performance Page 14 of 23 ABE25KX and ABD25KX User Manual High Flow Fan Characteristics STAT IC PRESSURE inwg SPEED rpm Page 15 of 23 ABE25KX and ABD25KX User Manual Functional Overview General This section describes the block up converter functions in detail The functional overview explains the RF amplification monitor amp control and power distribution IF RF Conversion and Amplification The IF Input requires a signal with a 1 OMHz reference and 36 58VDC or 80 240VA
12. erter The block up converter is extremely reliable requiring very little preventive maintenance or repair Should there be a malfunction this section also contains technical information to help diagnose basic failures Preventive Maintenance WARNING Shut down the block up converter before disassembly and remove all cables and connectors Failure to observe this precaution may result in personal injury or death This includes the removal of any RF power originating from other system components When the block up converter is in the hot stand by mode in a redundant system switch it to the operation mode at least once every three months Make sure the fan is running while in operation mode When the block up converter is in the cold stand by mode in a redundant system switch it to the operation mode at least once every three months Make sure the fan is running while in operation mode Block up converter Cooling System Preventive Maintenance Preventive maintenance is limited to checking the performance of the block up converter cooling system No electrical or mechanical adjustments are required for normal operation The fan is the least reliable item in the block up converter Wearing of the fan bearings will cause the RPM to drop and will create a higher than average heat sink temperature It is recommended to replace the fan after 3 years of operation Page 18 of 23 ABE25KX and ABD25KX User Manual Performance Check
13. ior to maintenance and or repair Procedure Verify that the installation procedure described was completed A complete physical check of the customer s system is suggested WARNING The output power available at the output waveguide flange is extremely hazardous Under no circumstances should block up converter be operated without the waveguide feed or a high power load attached Do not operate this equipment in the presence of flammable gases or fumes Failure to observe this precaution will result in personal injury Safe and careful installation of this block up converter will eliminate the possibility of accidents and provide years of top performance Verify the antenna feed waveguide connection is properly done before the block up converter is energized NOTE The block up converter can withstand any source or load VSWR However the block up converter will meet all specification requirements only if the source load VSWR is sufficient Normal operation is not possible if the antenna feeder VSWR is greater than 1 571 Turn ON the power and allow a warm up period of twenty minutes before operating the block up converter This will assure stable gain and power The block up converter can function with a coupler when a direct measurement of the output power is made Page 17 of 23 ABE25KX and ABD25KX User Manual Maintenance This section contains information on how to maintain troubleshoot and repair the block up conv
14. is not responsible for damage or loss of equipment during transit For further information contact the responsible transport carrier When declaring equipment as damaged during transit preserve the original shipping cartons to facilitate inspection reporting Return of Equipment When returning equipment to Actox Corporation for repair or replacement 1 Identify in writing the condition of the equipment 2 Refer to the Invoice Purchase Order and the date the equipment was received Notify Actox Corporation RMA department of the equipment condition and obtain a Return Material Authorization RMA number and shipping instructions NOTE Do not return any equipment without an RMA number This is important for prompt efficient handling of the returned equipment and of the associated complaint Page 5 of 23 ABE25KX and ABD25KX User Manual Preparing for Installation Before attempting to install or use the block up converter we recommend that you first familiarize yourself with the product by reading through this manual Understanding the operation of the system will reduce the possibility of incorrect installation thereby causing damage or injury to yourself or others The block up converter must be installed in accordance with the conditions and recommendations contained in the following sections Safety Precautions Carelessness or mishandling of the block up converter may damage the unit causing serious injury to yo
15. ive Care e Procedure e Block Up Converter Cooling System Preventive Maintenance e Performance Check e Troubleshooting e Out of Warranty Repair Appendix 1 Mechanical Drawing ccccceseceeeececeeeeeeeeeessueeaueeees 20 Appendix 2 Spare Parts Order FOrm 00cccccceeeeeeeeeeeceeeeeeeeeeeeeees 21 Appendix 3 M amp C Command6 000cccccee cece eee eeeeaeeeeeeeeeeeeeeeeengaes 22 Scope This document covers the installation operation and maintenance of the ABE25KX BUC It contains information intended for engineers technicians and operators working with the block up converter To make inquiries or to report errors of fact or omission in this document please contact Actox Corporation at toll free 866 888 6087 Page 3 of 23 ABE25KX and ABD25KX User Manual INTRODUCTION The ABE25KX ABD25KX is a reliable high quality cost efficient stand alone block up converter The application for this block up converter is Ku Band VSAT communication in an outdoor environment This line of superior products engineered using state of the art Gallium Nitride GAN technology and is characterized by unparalleled durability and dependability This is the smallest and lightest 25W L To Ku Band Block Up Converter and is designed to be mounted on the feed horn The unit is ideal for portable and mobile applications Double L O feature makes unit universal for Ku Band requirements This unit can be powered either with 18
16. ly with a Bias T for example ABT6ARN ABT6ARF manufactured by Actox Corporation or a similar bias T type Please make sure to check the sticker on the BUC for the appropriate power source before any power connections are performed e Powered via MS or IF Universal 38 56VDC A universal powered unit is powered through a 2 pin MS mating connector which is included with the BUC or IF input by an external minimum 300W 48VDC power supply source e Powered via only MS 38 56VDC MS only powered unit uses a 2 pin MS mating connector which is included with the BUC with 48VDC external power source with at least 300W e Powered via AC 80 240VAC The AC only powered unit has a 2 pin AC connector which is included with the BUC and this unit must have its own dedicated power AC plug in power source Ground screw is located on the BUC and should be properly marked Page 10 of 23 ABE25KX and ABD25KX User Manual Setting the L O Switchable L O is mechanically changed by unscrewing the L O screw and pressing it in with any small object such as toothpick If the BUC is equipped with M amp C interface the L O could be switching electronically with the appropriate M amp C command L O Status LED Orange Standard LO 13 05 GHz Green Extended LO 12 80 GHz Setting the TX and RX Frequencies All transmit and receive frequencies are set in the modem For a direct connection to an L band modem follow the manufacturer s instructions on setti
17. ng the transmit and receive frequencies Ensure that it is safe to transmit prior to enabling the transmission Page 11 of 23 ABE25KX and ABD25KX User Manual Recommended Test Equipment The following equipment or equivalent is recommended for installation and system alignment Equipment Type Spectrum Analyzer HP8563E Digital Voltmeter Fluke 8050 Adapter Waveguide to coax C or Ku band RF cables With calibrated insertion loss up to 15GHz 40 dB attenuator High Power to match HPA output Assortment of cables connectors and adapters calibrated up to 15 GHz Ensure that the BUC TX output power is disabled to prevent accidental transmission interference with adjacent satellites or transponders before attempting to align or performing any other operation involving the ODU Before attempting any system change carefully evaluate the possible effects of the transmitted signal Page 12 of 23 ABE25KX and ABD25KX User Manual Table 1 Specifications TECHNICAL SPECIFICATIONS RF frequency L O 13 05 GHz 14 00 to 14 50 GHz L O 12 80 GHz 13 75 to 14 50 GHz Local oscillator 13 05 GHz and 12 80 GHz IF frequency 950 to 1 700 MHz Output power P1dB min over temp 25W 44 dBm min N type or F type Power supply 190W max ABE25KxX auto ranging and auto detected 18 72 VDC via IF cable or MS connector ABD25KX auto ranging 80 240 VAC via MS connector WR 75 Grooved Gain variation over 40 MHz 0 8dBp_p over 500 MHz 14dBp_p Over ope
18. operly processed Indicate that a problem was encountered with the received packet X Device address of the packet source device ZZ CRC X Device address of the packet source device YY Error code 03 Incorrect CRC 18 Unrecognized command 30 Set command attempted on a restricted database element ZZ CRC 1 reply 7E FF F1 03 F2 7F NACK reply sent from the BUC for an invalid CRC 2 reply 7E FF F1 18 E9 7F NACK reply sent from the BUC for an unrecognized command Command Facket Explanation Possible replies Interpretation Examples format 1 cmd 7E FF 02 06 06 02 7F reply 7E FF 84 06 06 01 02 87 7F Get Device 7E FF 02 Query device for Update Device TT TT Device temp in C Temp 0x0102 0d258 273 15 C Temperature 06 06 02 current temperature Temp 7E FF 84 06 273 ZZ CRC 2 cmd 7E FF 02 06 06 02 7F 7F 06 TT TT ZZ 7F reply 7E FF 84 06 06 01 34 B1 7F Temp 0x0134 0d308 273 35 C 1 cmd 7E FF 02 06 07 03 7F reply 7E Get Power 7E FF 02 Query device for Update Device PS ae FR 810607010286 7E Temp U2 Supply 06 07 03 current power supply Temp 7E FF 84 06 TETIS PS tempin ie 00258 ie 2 cd 7E FE 02 Temperature JF temperature 07 TTTTZZ7F 273 ZZ CRC 06 07 03 7F reply 7E FF 84 06 07 01 34 BO 7F Temp 0x0134 0d308 273 35 C 1 cmd 7E FF 02 17 FF EA 7F reply 7E FF 84 17 FF 01 2C 41 7F Get Output 7E FF 02 Query
19. put signal to reset any alarm fault latches Securing the block up converter Align the block up converter output waveguide flange with the mating flange of the antenna feeder waveguide Using the O ring and hardware provided connect the antenna feeder waveguide Torque the flange screws to 16 inch pounds 1 8 N m Attach the proper cables for waveguide for IF input AC power and M amp C if equipped to the corresponding connectors of the block up converter The cylindrical connectors are labeled clearly and have different pin layouts It is impossible to incorrectly install the mating connectors Page 7 of 23 ABE25KX and ABD25KX User Manual Installing the Block Up Converter Tools and Test Equipment Have on hand a standard electrician s tool kit and any tools listed in the antenna manufacturer s installation instructions Site Considerations The BUC is designed to mount on the antenna Locate and install the antenna according to instructions supplied by the antenna manufacturer Choose an area that is free of extraneous interference from motors and electrical equipment and has a clear line of sight from the antenna to the satellite Lightning arrestors should be used at the site to protect personnel and equipment Preparation Mounting Considerations Optional Mounting Brackets are available that will facilitate mounting for most antennas The ODU must be mounted such that Sufficient support is afforded to the BUC the
20. rating temperature 0 75 dB p_p fixed frequency Third order intermod 3dB below P1dB 24 dBc typ at 3 dB total back off from P1dB Spurious within the Rx band 119dBm Hz max 10 95 to 12 75GHz 55dBc max 13 75 to 14 5GHz 73dBm max 10 95 to 12 75GHz L O leakage level at P1dB and below 25dBm Gain 70d Min 73 dB nominal Requirement for external reference via IF cable 10 MHz sine wave 5 to 5 dBm input port 55 dBc Hz max 10 Hz Phase noise 65 dBc Hz max 100 Hz 75 dBc Hz max 1 kHz 85 dBc Hz max 10 kHz 95 dBc Hz max 100 kHz PNoisefigure SS O 0Bmax Input V S W R 2 1 max Output V S W R 2 1 max Mute Shut off the BUC in case of L O unlocked Input interface ABD25KX ABD25KX 50 Ohm N type IF in ABE25KXF ABE25KXF 75 Ohm F type IF in Status LED Summary alarm All OK Standard LO 13 05 GHz Extended LO 12 80 GHz Temperature range ambient operating 45 deg C to 55 deg C storage 60 deg C to 75 deg C Dimensions amp housing 270 L x 120 W x 120 H mm 10 63 L x 4 72 W x 4 72 H 3 8 kg 8 4 lbs max Page 13 of 23 ABE25KX and ABD25KX User Manual Connections and Mounting Hardware The IF input connection requires a coaxial cable with an F or N type connector The RF output requires a waveguide with a WR 75 flat flange An O ring shall be used to seal the waveguide connection Assembly and Installation Use the information in this section as a guide to assembl
21. urself or others Please adhere to the following WARNING If your unit is equipped with an AC power cord and plug do not tamper with or attempt to reconfigure the cord or plug supplied with the unit as this can result in personal injury void the warranty Cause damage to the units or related equipment Page 6 of 23 ABE25KX and ABD25KX User Manual INSTALLATION AND OVERVIEW General Description This section describes the installation and theory of operation of the block up converter ABE25KX is powered by 18 72 VDC via IF cable or MS connector ABD25KX is powered by 80 240 VAC via MS connector power sources It will amplify an input signal from an L Band RF source up to a power level of 25 Watts P1dB CW in Ku Band The block up converter can be used as a stand alone unit or in a redundant configuration Specifications Table 1 summarizes the specifications of the ABE25KX BUC For mechanical specifications refer to the outline drawing Appendix 1 General Considerations The block up converter shall meet all specifications over full bandwidth and under all environmental conditions when terminated with a load of VSWR at 1 5 1 unless otherwise specified All RF specifications shall be met within five minutes after applying power except gain flatness which shall be met after a warm up period of ten minutes During the warm up period the block up converter shall not exhibit any alarm or require an RF mute in