Home

ROOM-TO-ROOM FAN

image

Contents

1. FAN HOUSING 7 Remove knockout on wiring box Fasten electrical cable to wiring box with proper connector for type of wire used Provide 6 152 4 mm leads inside box for electrical connections GRILLE BRACKET FIG 3 WIRING BOX GREEN OR BARE WIRE 14 Spin grilles onto mounting studs Turn on power and check operation of WHITE WIRES s fan Tighten grille flush against wall but do not distort grilles Bend grille bracket if necessary to make grille flush with wall COVER FAN HOUSING DISCONNECT ELECTRICAL POWER SUPPLY BEFORE SERVICING on this fan are lifetime lubricated and will never need oiling FAN Clean the fan blade and motor every six months by removing the grille Do not turn on the fan when starting a fire in a fireplace or wood stove until unplugging the motor and gently vacuuming the fan blade and motor the damper is thoroughly warm and fully open Turning the fan on too soon Clean the grille in warm soapy water Use a mild detergent such as a may draw smoke and flue gases into the room Wait until the fire is well dishwashing liquid DO NOT USE ABRASIVE CLOTHS STEEL WOOL established OR SCOURING POWDERS Always unplug the fan motor before servicing the fan The motor bearings 30040120 VENTILATEUR INTERPIECES MODEL 512 ee ee eee BROAN Broan NuTone Canada Inc 1140 TriStar Drive Mississauga Ontario L5T 1H9 DIRECTIVES D INSTALLATION 1 Tous les raccordements lectriques doivent se conformer
2. aux ordonnances et codes locaux ou au code canadien de l lectricit Si vous ne connaissez recourez aux services d un lectricien qualifi 2 Pour viter d endommanger les roulements du moteur ce qui risque de rendre le ventilateur bruyant ou de la d s quilibrer protegez le moteur des claboussures de la poussi re de construction etc 3 D branchez l alimentation lectrique avant d installer le ventilateur ou d en fairel entretien 4 Ne faites pas fonctionner le ventilateur pendant que vous allumez votre foyer ou votre po le bois car vous risqueriez d aspirer dans la pi ce les gaz et les fum es de la chemin e Attendez que le feu soit bien pris avant mettre le ventilateur en marche INSTALLATION DU VENTILATEUR 1 Planifiez votre installation Ce ventilateur peut se placer dans des murs ayant jusqu 5 1 8 130 2 mm d paisseur Si le mur a moins de 4 1 2 114 3 mm d paisseur il vous faudra fabriquer un carde d espacement voir l tape 14 On peut commander ce ventilateur par interrupteur mural ou par commande de vitesse disponibles s par ment D coupezle gabarit sur la bo te Suivezles instructions surle gabarit 3 D coupez soigneusement les ouvertures de ventilateur et l ouverture de laboite d interrupteur FIG 1 FIG 1 NO INTERRUPTEUR OU COMMANDE DE VITESSE VENTILATEUR PRISE MURALE ATTENTION Prenez soin de bien mesurer et marquer le centre de l ouverture de ventil
3. 14 64mm LEE CADRE a e GRILLAGE HE BO TIER DE VENTILATEUR Si le bo tier de ventilateur n arrive pas exactement l galit du bord du mur posez un mince bourrelet de pl tre ou d enduit de r paration le long du bord du bo tier pour remplir l espace entre le bo tier et le mur FIG 6 MUR di BO TIER PL TRE DE VENTILATEUR SUPPORT DE MUR pa 1 GRILLAGE 14 Fixez le grillage sur les tiges de fixation Mettez le courant et v rifiez le fonctionnement du ventilateur Serrez le grillage sur le mur mais sans le d former Pliez le support de grillage au besoin pour bien l appliquer au mur voir FIG 6 ET ENTRETIEN Nettoyez les pales du ventilateur tous les six mois enlevex le grillage en d faisant les vis du support de fixation du moteur et retirez l ensemble du moteur Passez d licatement l aspirateur les pales le moteur et le bo tier Ne plongez pas moteur dans l eau Nettoyez le grillage dans une eau savonneuse mod r ment chaude Servez vous d un d tergent doux comme un savon vaisselle N UTILISEZ PAS DE TAMPON ABRASIF DE TAMPON DE LAINE D ACIER DE POUDRE RECURER ETC 30040120
4. ROOM TO ROOM BROAN Broan Nulone Canada inc MODEL 512 FAN ahi Far Drive e 1 All electrical connections must be in accordance with local codes 3 Disconnect electrical power supply before installing or servicing fan ordinances or Canadian Electrical codes If you are unfamiliar with a methods of installing electrical wiring secure the services of a 4 Do not turn this fan on when lighting your fireplace or wood stove qualified electrician The fan may draw flue gases and smoke into the room Wait until 2 To avoid motor bearing damage and or noisy and unbalanced the fire is well established before turning on the fan impellers keep drywall spray construction dust etc off power unit INSTALL THE FAN 1 Plan installation Fan will install in walls up to 5 1 8 130 2 mm thick For 8 Make electrical connections Connect black to black white to white and walls less than 4 1 2 114 3 mm thick a trim board frame for spacing is bare or green wire to box using green ground screw required see Step 14 Fan can be controlled by a wall switch or speed 9 Position fan housing in wall Install wiring box and cover control available separately 2 Cut out template on carton Follow instructions on template 3 Carefully cut out fan openings and switch box opening FIG 1 10 Hold fan housing in wall and drill two 3 16 4 8 mm pilot holes through center of two slots in mounting flange FIG 4 Use slots in flange which li
5. ateur sur le mur oppos avant de d couper lune ou l autre des ouvertures AVERTISSEMENT LORSQUE VOUS D COUPEZ OU PERCEZ UN MUR PRENEZ BIEN SOIN DE NE PAS COUPER DES FILS ELECTRIQUES EXISTANTES 4 Enlevez la bo te de raccordement du ventilateur 5 D terminez le sens de l coulement de l air FIG 2 SUPPORT DE FIXATION BRIDE DE BO TIER PATTE DE SUPPORT SENS D COULEMENT DE L AIR BO TE DE Whee PRISE VENTILATEUR SUPPORT DE FIXATION AVERTISSEMENT AVANT DE FAIRE LES RACCORDEMENTS COUPEZ L ALIMENTATION LECTRIQUE DE LA PRISE LAQUELLE VOUS BRANCHEZ 6 Amenez le c ble lectrique l interrupteur et au ventilateur Faites le passer par l ouverture du mur du c t d arriv e du ventilateur et dans le bo tier du ventilateur FIG 3 7 Ouvrez un trou estamp de la bo te de raccordement Fixez le c ble lectrique cette bo te avec un raccord appropri au type de fil utilis Pr voyez des amorces de 6 152 4 mm l int rieur de la bo te pour faire les raccords lectrique BO TE DE RACCORDEMENT FIL VERT OU D NUD FILS BLANC COUVERCLE BO TIER DE ILISATION D BRANCHEZL ALIMENTATION LECTRIQUE DU VENTILATEURAVANT D EN FAIRE L ENTRETIEN Lorsque vous allumez un feu dans un foyer ou un poele bois ne mettez pas le ventilateurenmarcheavantqueleregistrenesoitbienr chauff etcompl tement ouvert Sivous faites partirle ventilateurtropt6tvous risquezd aspirer
6. dansla pi ce des fum es et des gaz de la chemin e Attendez que le tirage soit bien tabli D branchez toujours le moteur du ventilateur avant d en faire l entretien Les roulements du moteur son lubrifi s a vie et ne demandent aucun huilage 8 Reliez les fils lectrique noir au noir blanc au blanc et fil d nud ou verte la terre sur la bo te FIG 3 9 Placez le bo tier de ventilateur dans le mur Installez la bo te de raccordement et le couvercle 10 En tenant le bo tier de ventilateur dans le mur percez deux trous de guidage de 3 16 4 8 mm dans le centre des deux fentes de la bride de fixation Fig 4 Servez vous des fentes de la bride qui s alignent avec les ouvertures du support de fixation dans le bo tier du ventilateur DE FIXATION Re DE VENTILATEUR Fy aa LA BO TE DE RACCORDEMENT i ae a r x SUPPORT a BOITIER T 11 Installez les supports de fixation de l int rieur du bo tier de ventilateur et tirez les fermementsurl arri re du mur Assurez vous que les pattes du support sont entr es dans le bo tier de ventilateur voir FIG 2 12 Ins rez les vis travers les brides de fixation et serrez ferment les supports de fixation contre le mur 13 Sile mur a moins d 4 1 2 114 3 mm d paisseur fabriquez un cadre entourant le bo tier de ventilateur de fa on que celui ci se trouve en retrait de 1 8 3 2 mm 1 4 6 4 mm voir FIG 5 PANNEAU 1 8 3 2mm io Si
7. ne up with mounting bracket openings in fan housing FIG 1 ip ae i all 4 L MOUNTING 1 FAN HOUSING SWITCH OR SPEED CONTROL BRACKET 44 wg a E wane BOX FAN WALL OUTLET 11 Install mounting brackets from inside of fan housing and pull them tightly against back of wall Make sure tab on bracket is engaged in fan CAUTION housing FIG 2 Be sure to measure and mark center of fan opening on opposite wall E A T E tan enmon bae before cutting out either opening Insert screws through mounting HANJO and tighten mounting DracKets firmly againstwall WARNING rere A WHEN CUTTING OR DRILLING INTO WALL BE CAREFUL NOT i a NAS ES MaN ier l o aa e housing so that TO CUT EXISTING ELECTRICAL WIRING ousing is recessed 1 8 3 2 mm to 1 4 6 4 mm FIG 5 4 Remove wiring box from fan 5 Determine desired air flow direction FIG 2 FAN HOUSING FLANGE PANELING p 1 8 3 2mm 1 o g MOUNTING BRACKET GRILLE AES 114 64mm si AIRFLOW DIRECTION INLET MOUNTING BRACKET If fan housing is not flush with edge of wall material lay a thin bead of plaster or patching compound along edge of housing to fill gap between housing and WARNING DISCONNECT ELECTRICAL POWER TO OUTLET YOU ARE wall FIG 6 TAPPING INTO BEFORE MAKING ELECTRICAL CONNECTIONS WALL 6 Feed electrical cable to switch and fan Feed cable through wall opening al on inlet side of fan and into fan housing FIG 3 F