Home

PROFILE SPOT575 USER MANUAL

image

Contents

1. please use genuine parts If the power supply cable of this device becomes damaged it must be replaced by an authorized dealer only in order to avoid hazards Should you have any further questions please contact your local dealer BEAM SIZE 10 Degree Distance ft 80 90 100 110 120 Beam Diam 12 8 14 4 16 17 6 19 2 19 Degree Distance ft 40 50 60 70 80 Beam Diam 10 8 13 5 16 2 18 9 21 6 26 Degree Distance ft 30 40 50 60 70 Beam Diam 9 9 13 2 16 5 19 8 23 1 36 Degree Distance ft 10 20 30 40 50 Beam Diam 4 5 9 13 5 18 22 5 50 Degree Distance ft 10 20 30 40 50 Beam Diam 5 7 11 4 13 5 22 8 28 5 V20080814 PROFILE SPOT575 USER MANUAL Page 3 of 3 WARNING RISK OF FIRE KEEP DRY This fixture is intended for INDOOR USE ONLY Do not expose this fixture to moisture or rain NEVER operate the fixture if it is wet DO NOT OPERATE THIS FIXTURE WITHIN 3 FEET OF ANY FLAMMABLE MATERIALS This fixture can become extremely hot This is especially true when operated with high wattage lamps and when operated over long time periods DO NOT RESTRICT AIR This fixture must be installed so that air can freely circulate around all of its surfaces Do not block any holes or ventilation areas USE ONLY WITH SPECIFIED POWER TYPE Be sure the electrical power source matches the power requirements marked on the fixture USE THE CORRECT LA
2. MP This fixture can be used with multiple types of lamps Be sure that the lamp is the correct type and does not exceed the maximum wattage marked on the fixture A WARNING RISK OF ELECTRIC SHOCK KEEP DRY This fixture is intended for INDOOR USE ONLY Do not expose this fixture to moisture or rain NEVER operate the fixture if it is wet TURN OFF ALL ELECTRICAL POWER SOURCES BEFORE INSTALLATING THIS FIXTURE FIXTURE MUST BE GROUNDED This fixture is supplied with a earth ground wire and or grounding terminal The ground connection must be used Ensure that the device that the fixture is connected to contains a working ground connection DISCONNECT THE FIXTURE FROM ALL ELECTRICAL POWER SOURCES BEFORE SERVICING AN CAUTION HOT SURFACES Never touch the fixture or the lamp while it is operating Before servicing allow the fixture to cool for at least 15 minutes after turning it off USE SAFETY CABLE Use a safety cable when installing this fixture They are inexpensive and easy to use They are available from stage supply sources and some lighting companies BRIGHT LIGHT Lamps used with this fixture can produce light bright enough to damage your eyes Do not look directly into the light beam V20080814 V20080812
3. PROFILE SPOT575 USER MANUAL Page 1 of 3 TECHNICAL SPECIFICATIONS Power Supply 120VAC 60 Hz Maximum Ambient Temp 45 deg C Lamp 575 750W Maximum Housing Temp steady state 245 deg C Power Consumption 590W 760W Dimensions L x W x H 650 x 180 x 260mm Weight 6kg INSTALLATION During the installation DO NOT TOUCH THE GLASS BULB BARE HANDED Please follow the lamp manufacturer s notes Do not install lamps with higher wattage Lamps with a higher wattage generate temperatures the device was not designed for Damages caused by non observance are not subject to warranty During the operation the lamp reaches temperatures of up to 800 degrees C For the installation you need a 120V 575W GX 9 5 lamp or 120V 750W GX9 5 lamp PROCEDURE Unscrew the knurled screw of the lamp housing Remove the lamp housing from the device If replacing the lamp remove the old lamp from the socket Insert a 120V 575W GX 9 5 lamp or 120V 750W GX9 5 lamp into the lamp socket Do not operate device with opened lamp housing Reinstall the lamp housing OPOD LAMP ADJUSTMENT The lamp holder is aligned at the factory Due to differences between lamps fine adjustment may improve light performance Strike the lamp open the shutter and the iris set the dimmer intensity onto 100 and focus the light on a flat surface wall Center the hot spot the brightest part of the beam using the 3 adjustment screws A B C Turn one screw at a ti
4. chine technical installations are inspected by an expert after every four years in the course on an acceptance test The operator has to make sure that safety relating and machine technical installations are inspected by a skilled person once a year The following points have to be considered during the inspection 1 All screws used for installing the devices or parts of the device have to be tightly connected and must not be corroded 2 There must not be any deformations on housings fixations and installation spots ceiling suspension trussing 3 The electric power supply cables must not show any damages material fatigue e g porous cables or sediments Further instructions depending on the installation spot and usage have to be adhered to by a skilled installer and any safety problems have to be removed We recommend a frequent cleaning of the device Please use a moist lint free cloth Never use alcohol or solvents The objective lens will require weekly cleaning as smoke fluid tends to build up residues reducing the light output very quickly The venting slots should be cleaned monthly The interior of the device should be cleaned at least annually using a vacuum cleaner or air jet There are no serviceable parts inside the device except for the lamp Maintenance and service operations are only to be carried out by authorized dealers Please refer to the instructions under Installing Replacing the lamps Should you need any spare parts
5. me to drag the hot spot diagonally across the projected image If you cannot detect a hot spot pull the lamp in by turning all screws A B C clockwise 1 4 turn one at a time until the light is evenly distributed If the light is brighter around the edge than it is in the center or if light output is low the lamp is too far back in the reflector Push the lamp out by turning the screws A B C counterclockwise 1 turn one at a time until the light is bright and evenly distributed FOCUSING 1 Loosen the focus button on the underside of the device 2 Adjust the focus by sliding the lens housing forward or backward 3 Tighten the focus button POWER CONNECTIONS DANGER RISK OF ELECTRIC SHOCK The electric connection must only be carried out by a qualified electrician In order to connect the device to the mains you have to install a power plug connector Wiring for the power cable connector is as follows Wire Color Function International Brown Live L Blue Neutral N Yellow Green Earth V20080814 PROFILE SPOT575 USER MANUAL Page 2 of 3 The earth has to be connected Connect the device to the mains with the power plug If the device will be directly connected with the local power supply network a disconnect switch with a minimum opening of 3mm at every pole has to be included in the permanent electrical installation CLEANING AND MAINTENANCE The operator has to make sure that safety relating and ma