Home

PHOmo LUmo - autobio labtec

image

Contents

1. Assay validation to verify correct assay performance can automatically be performed based on formulas defining the required validation criteria Validation 1 PC1 gt 1 AND HC1 lt 0 2 Meas Value Meas Value 2 1 lt 0 15 Internal quality control function Used to monitor and statistically analyze controls over time and test runs Automatic replicate elimination Based on a formula outliers of replicated samples can be auto matically excluded from further evaluation Replicate Rejection Index Formula Base 1 PCT 0 S PCT lt POT 1 1 Meas Value Meas Value Min Rep 1 no gt P Database storage All data is stored in a database supporting flexible patient data result management sample based reporting including recor ding of external results flexible export functions reagent batch management etc Results from LUmo and PHOmo are assigned to the corresponding sample IDs Results of external tests can be added to the sample and printed in a com plete sample report Multitest and Kindling test Up to 12 different assays per sample multitest or up to 5 subsequently drawn samples of one patient kindling test can be processed on one plate Quick and scan measurement supports raw data acquisition and export for standard OD Quick Test Meas Parameter Meas Filter nm 405 gt Ref Filter nm lt gt z Sele
2. D cation increment 0 OD 492 nm and 0 005 OD JD 15 and 0 005 OD 3 0 3 5 OD lt 0 15 at 1 0 OD 5 sec single wavelength 8 sec dual wavelength kinetic interval up to 8 Standard 405nm 450 492 620 3 modes 33 5cm x 20 5cn x 47 0 cm wxh xl 13 0kg net external 100 240VAC 10 47 63Hz Serial Interface RS232 9 pin and USB 2 0 Temperature 10 C to 40 C Humidity 15 85 RH non condes Temperature 10 C to 50 C Humidity lt 95 RH non con dens Instrument with 4 filters 405 450 492 620nm power supply serial cable USB cable AUTOsoft Control and Evaluation Software Windows and user manual on CD on request e ua i wa ER a y N Autobio LUmo is a state of the art microplate luminometer designed to meet the demanding requirements of today s microplate based glow luminescence applications Product highlights High sensitivity 1 x 10 mole HRP allows detection of lower analyte concentrations earlier diagnosis of diseases and efficient tracing of treatments Large dynamic range 0 to 1 6 x 10 RLU Significantly increases assay linearity and enables reliable interpretation of very low and very high analyte concentrations in one test run without additional sample dilution Very low crosstalk LUmo incorporates a sophisticated adaptive positioning system keeping the detector as close as possible above the sample to el
3. Microplate Reader Un Luminometer eo Auiobio autobio labtec instruments an autobio group company www autobio labtec com Autobio Labtec Instruments Co Ltd was set up as a competence center focused on development production and marketing adding an own line laboratory instrumentation to the product portfolio of the Autobio group A close cooperation with an experienced R amp D team in Europe and a highly qualified team in charge of production enables Autobio Labtec Instruments to offer state of the art instrumentation to the domestic and international market Combining the expertise of our team of instrumentation specialists in Europe and China and the diagnostic background of Autobio our products are the result of a development making best use of synergies across the globe and our commitment to quality Autobio Labtec Instruments is ISO 9001 13485 certified All products are CE marked and meet the requirements for IVD Devices according to the In Vitro Medical Diagnostics Directive 98 79 EC Annex III Certified as IVD our products are qualified to be used with strictly controlled In Vitro Diagnostic applications LUmo and PFHOmo are designed to share a common platform with common advantages Most of the core components in electronics me chanics and software are Identical for both instruments Similar operation and maintenance within this product family improves efficiency and saves time and costs Following
4. rm rm re ks ko er e7 eas ras P23 P23 P31 ess P39 P39 Quantitative evaluation Curve fits modes linear regression point to point cubic spline and 4 parameter fit Axis scaling linear logarithmic logit log axis scaling and extra polation option 12 30 37 00 111 00 333 00 1 000 00 3 000 00 Standard curves can be stored and used for subsequent test runs as measured or adjusted by single or dual point calibrati on m Standards Value Y Value s1 0 03 266761600 52 0 06 2385809 00 53 020 159270050 s4 060 91772650 ss 150 50016150 C Lin Lin C Log Log SG 400 22719050 Log Lin Logit Log CL M IS CN MoO o Graphics Curve Point to Point e Cubic Spline C Linear Regression C 4 Parameter Fit Axis DAY Qualitative analysis Up to 3 different cut off values can be used to assign samples to up to 4 different ranges Classification is based on measure ment values concentrations or transformation result The desi red cutoff value can be selected to calculate the ration of cutoff value and measurement values of the samples M CO Group 1 lt Cutoff 1 lt Group 2 lt Cutoff 2 lt Group 3 lt Cutoff 3 lt Group 4 Groups Group 1 Poo y e Cutoff1 Nc102 Mess Value y M CO Group 2 POS EX Cutt f Mess Value C M co Group 3 fo EN Cutoff 3 Mess Vaux C MCO Group 4 fo am
5. LUmo and PHOmo provi ding a fully featured system ready to support your work in the laboratory Autobio Group offers more than 100 in vitro diagnostic products including ELISA POCT Point of Care Test Microbiology and CLIA Chemilu minescence As an ISO 9001 EN 13485 and GMP certified manufacturer Autobio supplies high quality products through its well established sales network andssreknown as a reliable OEM partner For details please visit www autobio diagnostics com Autobio Labtec Instruments Co Ltd No 2 Building Innovation Center No 1356 Hanghaidong Road National Economic and Technical Development Area Zhengzhou City PR China 450016 T 486371 6798 5313 F 86 371 6798 5804 E info autobio labtec com W www autobio labtec com flyer Instrumentation 20100309e
6. ct Wells Results Status NENE ENEE ES _ uos oros toro xea go 06000 90 tara cosa 197 M0 99 0 ffm e i fn aw ers ane ue as E pos 0 e ae a me 60 0607500 Meas Time x 0 1sec 1 ALL Wells Clear Luminescence Photometric pesos 00 sr xas 00500 foam o a fa ur on Lu am 00 1225 on I eee ees ee a oir oo om um uno and high resolution scan measurements Trans Copy paste and export displayed measurement result and sample data to use It in other applications e g Excel Sample IDs and patient data can either be entered manually generated automatically or imported from a file The corresponding results are displayed together with the sample data or printed in a sample report Details Results Sample ID 0812120011 Ta Name Faulk Name 14H Smith Mark 0812120011 Testi 11 830 HIGH 0812120011 LDL 35mmol Sex Male x 0812120011 HDL mmol Birth Date 28 07 1963 y Blood A y ID Card 12346 Deliver Dr Dr Cater v Sample Type Plasma y Sec Office Intemal Directory 1s used to manage commonly used data and simplify routine data entry Details 08121 20011 OEM customization and multilingual user interface The user interface of AUTOsoft can easily be customized to match the requirements of OEM customers regarding graphics and language Included with LUmo and PHOmo AUTOsoft is included for free with
7. en lamps LEDs require no heat up time and are only turned on during measurement LEDs show very low power consumption and no heat emission Large measurement range and excellent repeatability make sure the reader doesn t limit your application and impair your assay performance by poor precision High resolution scanning The sophisticated optical system of PHOmo is designed for high resolution scan reading Each well is measured at a resolution of 0 2mm providing 29 measurement values across each well This feature makes PHOmo the ideal choice for the measurement of agglutination assays Speed With a repetition rate of 5 seconds 8 seconds for dual wave length PHOmo doesn t keep you waiting for your results and enables fast kinetic measurements Filter slider for external filter access The filter slider can easily be moved out of the instrument to allow installation of new filters to the instrument No tool or service technician is required to install a new filter Specificatio Detection Method Measurement Modes Scan function Light Source ication nearity Repeatability Measurement time Filters Shaking Dimensions Weight Power supply Voltage range Data connections Environmental conditions Operating Storage Scope of supply Other filters a Self calibra ADSC Endpoint ano High resolutio up to 29 poinjs LED y 96 8x12 flat U a
8. iminate instrument related crosstalk and make optimum use of LUmo s high sensitivity and dynamic Speed It takes typically less than 40 seconds to read a 96 well plate at 0 1 sec integration time With fast Luminol based reaction systems high reading speed greatly improves assay precision across a plate Spectral Re Dynamic Indica or Range Measurement unit Otomultiplier module low luminescence 300 650nm O 1 600 000 000 RLU RLU Relative Light Units 1 x 10 mole HRP Sensitivity at 545nm Repeatability Crosstalk lt 2 lt 1x 107 typical Measurement time typically lt 40 seconds at 0 1 sec Integration time integration time for a 96 well plate 0 1 sec to 10 sec in increments of O 1sec 96 well and 48 well 4x12 micro plates max height 15 2 mm Plate types Shaking Dimensions 3 modes 33 5cm x 20 5cm x 47 0 cm w xh x 1 13 0kg net Weight Power supply external 100 240VAC 10 47 63 Hz voltage range Data connections Serial Interface RS232 9 pin USB 2 0 Environmental conditions Temperature 10 C to 40 C Operating Storage Scope of supply Humidity 15 75 RH non condensing Temperature 10 C to 50 C Humidity lt 95 RH non con densing Instrument power supply power cable dustcover serial cable USB cable AUTOsoft Autobio Control and Evaluation Software Windows and user manual on CD NYUTOs
9. o accommodate other instr valuable space in the lab LUmo and PHOmc top of each other The surface can be easily taminated No blower no noise The extremely low power consumption of t tronics generates no heat Accordingly no b which makes standby operation absolutely rature within the instruments remains at a any impact on the reaction in the plate The closed environment without air circulati significantly reduces the entry of dust and o which impair the performance of the optica service requirements and downtime of the are reduced TIA Td AR A ss ARDERE P eS BIA PROSS Robotic integration The accurate front loading mechanism which releases the plate in load position it s compact design and reliability make LUmo and PHOmo the ideal choice for integration into robotic sys tems If necessary the front panel can be easily removed OEM LUmo and PHOmo are both available as OEM version with cus tomized paint and labeling tate of the art microplate reader anding requirements of tod nic applications Autobio PHO designed to i microplate base Product highlights Reliability ae Using a state of the art LED light source togetagn with aJftoma tic calibration and adjustment the design of PHOnT dssures reliable measurement performance and minimum maintenance The internal software automatically monitors and adjusts the power required Unlike commonly used tungsten halog
10. orFT AUTOsoft control and evaluation software Autobio considers software used to control the instruments and perform the required evaluation as integral part of an efficient system focussed on processing the variety of microplate based applications AUTOsoft Autobios powerful Windows control and evaluation software is designed to perform the vast majo rity of routine and scientific applications AUTOsoft is supplied free of charge with LUmo and PHOmo Unlike other manufacturers Autobio supplies a powerful eva luation package with the instruments and not just a basic data acquisition program which has to be upgraded for significant additional costs in order to provide the features required by the user AUTOsoft features and highlights User administration User Administration with 2 different authorization levels User Name Maria Password Cancel Change Password Plate Layouts can be defined and saved independent from the test definiti on using convenient positioning filling and replicate functions Type Filling Direction CP NC CBL CK al Current Type C Horizontal Vertical Da eat 211 z s Fill Clear Clear All Layout Factor Replicate SADA Layout Factor 1 Number m le Horizontal Vertical EC men paz paz ana Pa e ose ver 027 ms as P12 ss vs vs eses vas oa vm vm x rs os ve ve re 09 02 02 wm
11. some of the main product highlights common with LUmo and PHOmo are listed State of the art design LUmo and PHOmo have both been developed by a very expe rienced team in Europe Using state of the art technology and more than 20 years of experience in microplate instrumentation the development was focussed on top level performance cost efficiency and reliability IVD ISO SIVDCE Both LUmo and PHOmo have passed all required tests and reviews carried out by independent certified bodies to cer tify compliance with the relevant directives 98 79 EC IVD 2004 108 EC EMC and 2006 95 EC LVD USB and RS232 serial interface The instruments incorporate both a USB anc to connect the instrument with the compute the instrument can be connected no matte are installed in the PC RS232 interface his makes sure Front Loader LUmo 8 PHOmo The front loading mechanism is designed to LUmo and PHOmo in a robotic operating e The plate can be easily positioned and acce easy and safe loading the plate is not locke transport is located in load position and onl position once the plate carrier moves into t If a plate is dropped the instrument itself wi reduces service and maintains the value of t plate carrier can easily be cleaned and deco position Accommodates 96 and 48 well micropla The plate carrier system is designed to acco of 96 and 48 well 4x12 microplates witha adaptor required Flat top surface can be used t

Download Pdf Manuals