SCANORA ® 5.0 Installation Manual

image

Contents

1. 41 4 8 Worklist ConflguraliOpis ooi pene a adi o ER URS hit Leas 43 4 3 1 VVOIKEISL SGP BOX Ee iot tates 43 4 3 2 Search for worklist items by date 45 4 3 3 Modalities BOX sina nA AA RNI seo poe I ae 45 4 3 4 Scheduled Sali ni eret eee 45 4 3 5 Worklist Page buttons enit eo add Di oq 45 2 35 0 Other option Sz eei oe ak A la a 48 4 4 Storage and Storage Commitment configuration 49 4 4 1 Storage page b eite 50 4 4 2 Storage page Attributes List buttons 53 4 4 3 Storage Commitment settings 55 4 5 Print configaralign s cu teet tient tein eene i edite 57 4 5 1 Print page Destinations aane dani 57 4 5 2 Print page Attributes List buttons 60 4 6 Query Retrieve configuration ecececiceseiieeee conoce reor entente etre nn tnnt 61 4 6 1 OGB 25 2 aene od E EN hen edid 63 4 6 2 The Log Files and Performance 65 Wo Storage m 66 207633 rev 2 SOREDEX i 10 4 8 Log File and Performance Settings kina 67 Z9 GIOSSANY tore ee a o O ate tdt e oia 7
2. Charset Shown Attributes Patient s name Modality Sched Station name gt Accession number a Patient s ID Scheduled procedure step Scheduled Station AE Title Sched procedure start de Sched procedure start tir Sched Physician s Name Sched procedure descrip Sched procedure Locatiot Scheduled Item code Code value Sched proc Coding Scheme designato al Pre Medication Sched procedure ID Req contrast agent Req procedure ID Req procedure Descriptic x nocedua coda The Shown Attributes list includes the attributes that appear in the software Worklist window The attributes in the hidden attributes list does not appear in the window To move the attributes from one list to another Click on the attribute to move the attribute changes color Click the arrow to move the attribute in the direction required or Click on the attribute to activate it Without releasing the mouse button drag the attribute to the other list or within the list to change the place of the attribute then release the mouse button drag and drop NOTE the changes made in the Columns window remains temporary after clicking OK To save the changes permanently click OK or Apply in the DICOM Worklist configuration tab Colors button Click Colors and the Set Colors window appears To change a status color click the appropriate arrow button beside each color A
3. Application Entity Title Workstation Query Model Model Patient root X QR Scheduler Failed retrieve retry count Retry interval minutes Advanced Cancel Complete the fields as follow AE Title Obtain from the hospital administrator for example OR SCP 207633 rev 2 SOREDEX 61 4 Configuring DICOM 62 IP address Obtain from the hospital administrator for example 10 0 0 2 Port The TCP port on which the remote DICOM system listens for connections The default DICOM port number is 104 Obtain from the hospital administrator Verify button See the Verify button in the previous chapters of this manual for more information Application Entity Title for Move Service Specify the AE Title of the target Application Entity i e the AE where the retrieved images are sent Typically this is the local Storage SCP AE Query Model Select either Patient Root or Study Root Failed Retrieve Retry Count This is the limit for the retry attempts that would made after retrieving is failed O means that not retries are done if the initial retrieve attempt Retry interval This is the time interval in minutes that will be waited between the retries The Advanced Button See or make any changes to the patient image search click Advanced The Advanced window appears SOREDEX 207633 rev 2 207633 rev 2 4 Configuring DICOM IM 5 Query Options Log Files Performance Model Pati
4. See Soredex web page to get additional information about PMS interface SOREDEX 111 10 Using practice management interface 112 SOREDEX 207633 rev 2 11 Software license 11 Software license 207633 rev 2 THIS DOCUMENT IS A LEGAL AGREEMENT BETWEEN YOU AS THE lt LICENSEE gt AND PALODEX GROUP OY THE lt LICENSOR gt GOVERNING YOUR RIGHT TO USE THE SCANORA SOFTWARE lt Software gt IF YOU AGREE TO BE BOUND BY THE TERMS AND CONDITIONS OF THE SOFTWARE LICENSE AND THIS PARAGRAPH PLEASE PRESS lt Agree gt AT THE PROMPT BELOW IN WHICH CASE YOU AGREE THAT THIS AGREEMENT IS ENFORCEABLE LIKE ANY WRITTEN NEGOTIATED AGREEMENT SIGNED BY YOU IF YOU DO NOT CONSENT TO THE SOFTWARE LICENSE AND THIS PARAGRAPH PLEASE PRESS lt Cancel gt AT THE PROMPT BELOW IN WHICH CASE THE SOFTWARE WILL NOT OPERATE AND RETURN THE SOFTWARE AND THE ACCOMPANYING ITEMS TO YOUR PLACE OF PURCHASE FORA REFUND 1 Subject matter of the Software License This Software License governs the use of the Software Software means the software product specified above including new versions or updates of the Software made generally available to other licensees of such Software free of charge if any 2 Software License Grant 2 1 Licensor hereby grants you a non exclusive and non transferable license to use during the term of this Software License i the Software in object code form only and in accordance with the terms of this Software License and ii
5. 1 Printer name Application refers to the printer by a DICOM Application Entity Title AE Title and this is the same way it is referred to in the application profile In this field enter a name for AE Title for example DICOM PRINTER AE Title Obtain from the hospital administrator for example PRINT SCP IP address Obtain from the hospital administrator for example 10 0 0 3 Port The TCP port on which the remote DICOM system listens for connections The default DICOM port number is 104 Obtain from the hospital administrator Capabilities If the DICOM printer supports grayscale OR color printing select Basic Grayscale Print Management Basic Color Print Management If the printer supports both printing modes select either or both modes Refer to the operating manual supplied with the DICOM printer for more information Click OK after entering all the required information A print page appears which indicates that a new printer has been successfully added to the list SOREDEX 207633 rev 2 4 Configuring DICOM The top list shows the configuration information that has been entered The bottom list shows all the printer s attributes and their characteristics Tag number Name Module Type and default value Repeat the above procedure each time to add a DICOM printer Print page Edit button Change the information in the printer list 1 Select the printer to be edited 2 Cli
6. SOREDEX 33 3 Driver installation 34 Format Use Close after image snap slide bar to specify how many seconds a capture image stays top of the screen after capturing Use Capture Delay to prevent camera shake caused by button press It is the delay between IntraCam s button click and actual image capture Set the value in the Delay editbox of IntraCam s settings dialog Use Shortcuts to configure shortcut keys to start capture session snap image and end capture session The default values for the same are Start capture F4 Snap image F5 End capture F6 NOTE The software supports Durr Dental s PC COM port connectable 3 button foot pedal 3 2 1 Video Format dialogs Click Format to open the window x Video Decoder Video Proc Amp Video Standard PAL_B Signal Detected 0 Lines detected 625 z YER Input Output Enable E Cancel Select the used Video Standard on Video Decoder tab These alternatives vary according to camera manufacturer and country SOREDEX 207633 rev 2 3 Driver installation Properes x Video Decoder Video Proc Amp Brightness Contrast i Hue Saturation j Sharpness Gamma H white Balance 42 Backliaht Comp S GolorEnable F Default Tm ple m la ua
7. 2 Software installation 7 General location Choose Destination Location Select general destination folder for the software and click Next For 32 bit platforms Default destination is C Program FilesISCANORA For 64 bit platforms Default destination is C Program Files x86 SCANORA 7 Scanora 50 1 InstallShield Wizard j Choose Destination Location Select folder u ap will install file m S InstallShield 18 SOREDEX 207633 rev 2 2 Software installation 8 Select Features Select the features to be installed to this workstation This selection should be made carefully observing the descriptions Scanora 5 01 InstallShield Wizard Select Features Select the features setup will install wamt to install Common Database engine Database sharing Client C Common Image capturing C Client touch panel mode S amp A A ol TM ae we au Standalone system Select all needed features but no Database sharing Network system Select database sharing at database workstation Modality workstation only Select Image capturing Click Next 207633 rev 2 SOREDEX 19 2 Software installation 9 Select used device for enabling image capturing Click Next 5 0 1 InstallShield Wizard Select devices to be in
8. Color selection window appears SOREDEX 207633 rev 2 207633 rev 2 4 Configuring DICOM x Status Color New TE z Taken ii zl Stored pesi x Cancel Select a basic or custom color for the required status and click OK NOTE A the changes made in the Color window remains temporary after clicking OK To save the changes permanently click OK or Apply in the DICOM Worklist configuration tab SOREDEX 47 4 Configuring DICOM 48 Advanced button The Log Files and Performance pages provide parameters for adjusting the low level settings of the DICOM network services There are similar settings for all the DICOM network services See chapter 4 8 Log File and Performance Settings 4 3 6 Other options Hide following worklist items Choose the option that suits best Option Effect None Items are not hidden Older than current date All items older than current date are hidden Stored All items that are stored older than current date and older than current date are hidden Copy Scheduled Procedure Step Description to Study Description If this option is selected then Scheduled Procedure Step Description is copied automatically to the Study Description tag Copy Requested Procedure Description to Study Description If this option is selected then Requested Procedure Description is copied automatically to the Study Description tag Study date time This setting controls how the Stud
9. UID Unique Identifier SOREDEX 71 4 Configuring DICOM 12 SOREDEX 207633 rev 2 5 Software database 207633 rev 2 5 1 Installing the software database to existing MS SOL server If MS SQL Server software already exists on the computer where the software database is to be installed Microsoft SQL Server 2005 or Microsoft SQL Server 2008 SP1 Microsoft SQL Server 2008 R2 Workgroup Standard Enterprise Edition NOTE EDBI is not supported in a 64 bit MS SQL Server The software database can be installed to existing Microsoft SQL Server database engine instead of using Microsoft SQL Server 2008 Express Edition engine which is provided by the software installation package the Database engine feature If more advanced configuration options are needed see _ the ADBlinstallation pdf located in the ADBI folder of the software DVD A named instance is required for the software database An instance can be created during Microsoft SQL Server Setup Installation to default unnamed instance is not supported The SQL server must be configured to use mixed mode authentication In addition the TCP IP protocol and named pipes must be enabled To use mixed mode authentication start SQL Server Management Studio In Vista SQL Server Management Studio should be run as an administrator In SQL Server Management Studio Object Explorer select server and then right click for properties On the security page under Server Authen
10. by Licensor or its suppliers of this Software License you shall within two 2 business days thereafter certify to Licensor that in accordance with instructions from Licensor or its suppliers all copies of the SOREDEX 207633 rev 2 207633 rev 2 11 Software license Software have been either destroyed or returned to Licensor whether same is in tangible or intangible form and you shall further certify that all use thereof is and shall remain terminated 3 4 You agree to comply with all applicable export and re export restrictions and regulations including the ones imposed by the government of the United States or of the country to which the Software is shipped to you You shall not commit any act or omission which will result in a breach of any such export reguirements 3 5 Should you receive any copy of the Software to upgrade a previous version of such Software such upgraded version of the Software shall be the only version you are entitled to use unless otherwise agreed and unless expressly otherwise permitted by Licensor you shall destroy or erase all program material and related documentation including all copies and modifications relating to the previous Software Copyright 4 1 The Software shall be delivered subject to all restrictions and protections provided for under the applicable copyright and other laws and treaties Except as otherwise may be agreed by Licensor in writing you have no right to reproduce or
11. manuals and other documentation related to the Software You have no right to sublicense the Software and you are under the obligation to return the same to Licensor upon the expiration or termination of this Software License 2 2 You are entitled to use each licensed Software only on a single computer or terminal at any one time and if necessary for use on such computers or terminals to modify the Software or merge them into another program portions of the program continuing to be subject to this Software License in full Such other program must however conform to all applicable local laws regulations on patient imaging systems Licensor shall not be held liable for any damages resulting directly or indirectly from a modification or merger of the Software made by you SOREDEX 113 11 Software license 114 even if Licensor approved such modification or merger 2 3 You are granted no rights hereunder other than those expressly set out hereinabove and consequently all other activities related to the Software are prohibited Such prohibited activities include but are not limited to i the deleting adding to copying modifying or transferring the Software or any part thereof or any copy or merged portion thereof in whole or in part except as expressly provided for herein or authorized in advance by Licensor in writing and ii the renting or leasing of the Software to another party Software License Limitations and C
12. type specifier for the values that can be assigned to an attribute This includes the data type as well as its format The Value is the variable to which the value stored in the attribute is assigned To change or remove one of the list items first select the item in the list and then click the corresponding button C Find Request Cao ER C The edit or remove dialog appears with the fields containing the data of the item to be changed or removed SOREDEX 207633 rev 2 207633 rev 2 4 Configuring DICOM Tag VR String v Value PATIENT Cancel After the changes click OK to accept them To remove an item the following confirmation message appears CIT x e Are you sure you want to delete the Tag 0008 0052 Up and Down buttons These buttons are located in the bottom left hand corner of the advanced dialog in the C Find Response group box They can only be used with that list r C Find Response 0010 0010 0010 0020 0008 0054 uli si With the Up and Down buttons change the order of the list items Select the item to move up or down the list and then click UP DOWN 4 6 2 The Log Files and Performance pages The Log Files and Performance pages provide parameters for adjusting the low level settings of the DICOM network services There are similar settings for all the DICOM network services See chapter 4 8 Log File and Performance Settings S
13. 1 1 DICOM License number The DICOM license key is managed through the license key of the software The license key of the software is entered either during the software client installation or in the software Manager after the installation 4 1 2 Retired Command Elements Controls are provided to select how the software uses the command elements that have been retired from the DICOM standard 3 0 It is recommended to leave these controls empty SOP Class configuration The software allows to configure which SOP Class is used to correspond the image types of the software DICOM settings SOP Classes Worklist Storage Print Query Retrieve Storage SCP Digital X Ray Image Storage For Processing Digital X Ray Image Storage For Processing DX Digital Intra oral X Ray Image Storage For Processing 1 Photographic Image Storage Enhanced CT Image Storage CB3D scout Digital X Ray Image Storage For Processing DX SOREDEX 41 4 Configuring DICOM 42 Panoramic images Digital X Ray Image For Processing PX default Digital X Ray Image For Presentation PX Digital X Ray Image For Processing Digital X Ray Image For Presentation Computed Radiography Image Storage Cephalometric images Digital X Ray Image For Processing default Digital X Ray Image For Processing DX Computed Radiography Image Storage
14. Configuring DICOM The Log message levels are as follows Error level This level logs error messages These messages mainly occur when the network fails or when reading in or writing DICOM messages Warning level This level logs warning messages Info level This level logs informational messages T1 level not used T2 level This level logs the entire contents of messages sent or received over the network T3 level This level logs information related to association negotiation T4 level This level logs information when incoming associations are being rejected T5level This level logs information when a message is validated T6 level This level logs the contents of the Merge tool kit configuration T7 level This level logs the contents of a the command elements group 0 for received and sent messages T8 level This level logs warning messages related to streaming in or out messages and files T9 level This level logs information about PDUs sent or received Blank fill log file If this feature is selected the log file size is to be expanded to the maximum possible size Backup old log files If this feature is selected old log files are backed up Historical log files To select the number of historical log files saved The Performance Page allows various parameters to be changed to improve performance 68 SOREDEX 207633 rev 2 4 Configur
15. Intra images Digital X Ray Image For Processing DX default Digital X Ray Image For Processing DX Digital Intra oral X Ray Image Storage For Processing Digital Intra oral X Ray Image Storage For Presentation Photographic images VL Photographic Image Storage default Secondary Capture Image Storage Multi frame Grayscale Byte Secondary Capture Image Storage Multi frame Grayscale Word Secondary Capture Image Storage Multi frame Truecolor Secondary Capture Image Storage CB3D Enhanced CT Image Storage default CT Image Storage CB3D scout Digital X Ray Image For Processing DX default Digital X Ray Image For Processing DX Computed Radiography Image Storage SOREDEX 207633 rev 2 207633 rev 2 4 Configuring DICOM 4 3 Worklist configuration DICOM settings General SOP Classes f Storage Print Ouery Retrieve Storage scp r Worklist SCP Application Entity Title DICOM_AE IP address or host name 127 0 0 1 Port number 104 Polling interval sec 60 Refresh timeout sec 30 Search method Refresh from worklist SCP iz Verify r Items retrieved Days before current date 0 Days after current 0 r Modalities px px Io Other ca ma jem r Scheduled Station Use this AE Title _ Advanced Columns Colors Hide following worklist items Stored older than current date m Copy S
16. Once the focus the line is selected is put into one of the attributes in the storage attributes list the rest of buttons are enabled DICOM settings General SOP Classes Worklist Storage Print Query Retrieve Storage SCP Store images automatically when saving Copy slot title to Image Comments 0020 4000 when storing an FMS Destination AE Title IP Address Port Number Set as Default Advanced Add new Tag Name Type Default Value Storage Commitment Use Storage Commitment The Attributes list includes default attributes for the DICOM application Add and edit the attributes or delete them from the list SOREDEX 53 4 Configuring DICOM 54 Attributes list Add new button To add a new attribute to the storage attribute list click Add New The Add New Tag window appears Add New Tag 3 I x Tag 00041130 File set ID Type Replace if empty z Default A message is constructed from attributes having values and each attribute is identified by a tag An attribute is a unit of data e g Patient s Name Patient 10 A tag is 4 byte number identifying an attribute e g 00100010H for Patient s Name A tag is usually written as an ordered pair of two byte numbers The first two bytes are sometimes called a group number and the last two bytes are called an element number 9 0010 0010 0038 00
17. from the Software The prohibition in the foregoing sentence shall apply only to the extent permitted by applicable law When information of the internal structure of the Software is necessary in order to obtain interoperability of the Software with other software programs you shall immediately contact Licensor Disclaimer of Warranties 6 1 To the maximum extent permitted by applicable law Licensor and its suppliers provide the SOFTWARE lt as is and hereby disclaim all warranties and conditions either express implied or statutory including but not limited to any if any implied warranties or conditions of merchantability of fitness for a particular purpose compatibility of lack of viruses of accuracy or completeness of responses of results and of lack of negligence or lack of workmanlike effort all with regard to the SOFTWARE and any part thereof and the provision of or failure to provide support services There is also no warranty or condition of correspondence to description or non infringement with regard to the SOFTWARE or any part thereof Licensee shall bear the entire risk as to the quality or compatibility of or arising out of use or performance of the SOFTWARE 6 2 To the maximum extent permitted by applicable law in no event shall Licensor or its suppliers be liable for any actual or special incidental indirect or consequential damages whatsoever including but not limited to damages for loss of profits o
18. in these locations Use the check boxes below to limit or expand the default search which includes local paths and removable media The best driver found will be installed Search removable media floppy nelude thi Don t search will choose the driver to install Choose this option to select the device driver from a list Windows does not guarantee that the driver you choose will be the best match for your hardware lt Back Next gt Cancel 207633 rev 2 SOREDEX 27 3 Driver installation 28 3 Select Imaging devices and Click Next Found New Hardware Wizard Hardware Type ma Select a hardware type and then click Next Common hardware types Aj Infrared devices Keyboards x Medium Changers V Mice and other pointing devices b Modems 9 Monitors D Multifunction adapters AM inen serial adantere lt Back Next gt Cancel 4 Click Have Disk Found New Hardware Wizard Select the device driver you want to install for this hardware Select the manufacturer and model of your hardware device and then click Next If you have a disk that contains the driver you want to install click Have Disk Unable to find any drivers for this device Cancel 5 Insert the software installation DVD into the DVD ROM and browse the PCI driver DdxDrv inf from path SCANORA DVD gt Drivers PCIDrv Install From Disk Insert the manufacturer s installation disk and the
19. is to be changed Fill in the patient data fields to be changed If the content of a specific data field is not needed to be changed set its value to O Re start the software To preselect a patient Set USE_PRACTICE_MANAGEMENT 1 Set PATID to match the patient to be preselected Set all data fields to 0 Re start the software To disable the practice management interface Set USE_PRACTICE_MANAGEMENT 0 110 SOREDEX 207633 rev 2 207633 rev 2 10 3 10 Using practice management interface Interface to access image information NOTE f images are brought into another software and to be used for diagnostic purposes this software must conform to applicable local laws and regulations on patient information softwares The software supports external application called PMSIf which provides direct access to images in the software database has four fields which can be used together with PMSIf to export the image Image ActivelmageGUID ActivelmagelD LastCaptureGUID Activelmagelndex Use ActivelmageGUID or ActivelmagelD to export the image visible in currently active image window from database ActivelmageGUID is preferred over ActivelmagelD retried Use LatestCapturedlmagelD to export latest captured saved image from database Only the latest ID s of the saved images are shown LastCapturelD and LastCaptureGUID are visible after the first image is captured
20. next chapter 5 4 2 How to reconfigure Database connection ODBC clients all SCANORA 3 2 or later software on workstations and server if any NOTE Make sure that nobody uses the software before the database connection has been completely reconfigured otherwise some data is saved to the old database SOREDEX 207633 rev 2 207633 rev 2 5 Software database 5 4 2 How to reconfigure Database connection ODBC 1 Open Start Settings Control Panel Switch to Classic View Administrative Tools Data Sources ODBC Select the System DSN tab Select SCANORA and click Configure Select The new server SCANORA from the list and click Next Select With SQL Server authentication using a login ID and password entered by the user Also Connect to SQL Server to obtain default settings for the additional configuration options must be checked Write username by default admin to the Login ID field and password by default admin to the Password field and click Next Click Next again Click Finish OK and OK SOREDEX 83 5 Software database 84 5 5 Renaming Database Computer There are certain steps that need to be taken when renaming computer which hosts the software database with database sharing These steps are done after the renaming is completed 5 5 1 Configuring the file server To configure file server to use the new computer name open the software manager and selec
21. ooo ane ae le a eee cee eee ee 89 TA Addi g devices isi ee usa RA Non 89 7 2 Adding Oplions 345 a ee kia oi E UN d 90 Uninstalling doeet pun Depuis aU DUM ke ale palet 91 8 1 Uninstalling the software oe ee eost cede oe nia 91 Software Marnager nacen tiende ei NENA DIL etat teat 93 SM Eos per 93 9 22 ete rent iul orta eedem e la da hese deck ole ned 94 9 2 1 Create archive eel po AR Re oen iudi es 94 9 2 2 Restore AO NIVO eut imei PE 95 9 3 Images oo de e ut tete ueni Le RUE d 96 9 3 1 m 96 TI RU ener 97 9 3 9 Image 01 ee tea teeta 97 9 3 4 Report Exposure statistics portato tee o ere dea eiua a needed 98 WDALAD ASE a LE el ceo Gl eh ie o tur ees Lt 100 9 4 1 User AMAGSINICI NE t a td i 100 9 4 2 Database backip a uu a aerea dav NA S RR 101 OAS MAS ine rand oomen tese es aum bg i Coat ue 102 94A System OOS oa c b tatus te 103 9 44 1 SearchnilogS oce pede pia era need 103 9 5 File Server Configuration NORA ect eee 104 9 6 COIS RE HR DL PTT Tc 104 Using practice management 107 SOREDEX 207633 rev 2 10 1 IMtFOGU CHO M 107 10 2 How to SCANOFRA IDE idet an reet dee oa dal date re o
22. the license key provided with the software 207633 rev 2 SOREDEX 105 9 Software Manager 106 SOREDEX 207633 rev 2 10 Using practice management interface 10 Using practice management interface 207633 rev 2 10 1 NOTE f patient data is tranferred in to the software by other software this software must conform to applicable local laws and regulations on patient information softwares Introduction The software uses initialization file called SCANORA ini The file is installed in the software settings directory which is operating system specific Windows XP C Documents and Settings All Users Application Data SCANORA Windows Vista C ProgramData SCANORA However for compatibility reasons the software still uses the old CliniView ini file path in Windows XP if the practice management software continues to write data to it This file is installed in windir folder and windir is the folder where Windows is installed for example C Windows Windows XP Viewing System Variables e g windir 1 Click Start point to Settings and then click Control Panel Double click System On the Advanced tab click Environment Variables All current system variables and their associated values are listed in the lower list The installation directory and executable path are defined in Windows registry HKEY_LOCAL_MACHINE SOFTWARE Soredex SCANORA ProgramDir SCANORA path for example C Pr
23. to be added Click Add new and the Add New Destination window appears Fill in the fields as follows 1 Destination Section describing a remote DICOM application Client refers to the destination by a DICOM Application Entity Title AE Title and this is the same way it is referred to in the application profile A destination name can be for example DICOMArchive 2 AE Title The AE Title is a string of 16 characters or less with no spaces for example STORAGE SCP NOTE The AE Title string is case sensitive 3 IP Address a remote host name or its IP address for example 10 0 0 2 4 Port a TCP port which the remote DICOM system listens to The default DICOM port number is 104 Obtain from the hospital administrator 5 f Storage Commitment feature is used define the Storage Commitment SCP settings either choose the Use the same destination for Storage Commitment option or define the Storage Commitment SCP AE Title IP address and TCP port explicitly Note Port number must not be greater than 65535 When defined the storage destination click OK The storage page appears with the new destination in the upper list and the attributes in the lower list This indicates that you have successfully added a new destination to the storage application Repeat the above steps each time to add a new destination SOREDEX 207633 rev 2 207633 rev 2 4 Configuring DICOM Storage page Delete button Allows a d
24. 0 Software database savi ni SEAN NAR Me daje deje 73 5 1 Installing the software database to existing MS SQL server 73 5 2 Changing the software database location 76 5 2 1 Changing database location by uninstalling local database using Modify 76 5 2 2 Changing database location by modifying ODBC alias 77 5 2 3 Changing Standalone database to Network database using Modify 78 5 3 Database backup and restore ira pr xta co pei tnra dante 79 5 3 1 Making instant backup from the software database 79 5 3 2 Restoring the software database from the 80 5 4 Restoring database to a new installation and or 81 5 4 1 How to restore a database to another installation or new location 81 5 4 2 How to reconfigure Database connection ODBC 83 5 5 Renaming Database COITIDULBr ctas reas led bt ee eec or eden ei 84 5 5 1 Configuring the file server ne 84 5 5 2 Modifying DataSource bebe ele ae BEAN 84 5 5 3 Modifying Already Installed Clients to Use New Database Computer Name 85 Upgrading the S ORW cem 87 6 1 Upgrading the software from version 3 1 or 87 Adding
25. 08 5 1 2 840 100068 STANDARD DX PRESENT SCP EXPLICIT LITTLE EN 1 2 840 10008 5 1 2 840 10008 STANDARD DX PROCESS SCP EXPLICIT LITTLE EN 1 2 840 10008 5 1 2 840 10008 STANDARD ECHO SCP EXPLICIT LITTLE EN 1 2 840 10008 1 1 1 2 840 10008 STANDARD HARDCOPY C SCP EXPLICIT LITTLE EN 1 2 840 10008 5 1 2 840 10006 STANDARD HARDCOPY G SCP EXPLICIT LITTLE EN 1 2 840 10008 5 1 2 840 10008 CTAMDAND TA DNECENIT cen 1 CM 1 2 1nnno c 1 5 Print Preview Save As SOREDEX 207633 rev 2 207633 rev 2 4 Configuring DICOM The DICOM parameters are from the destination The Network are parameters that provide information about the status of the communication with that remote entity If communication fails the Network status is Failure and the Association status explains the cause of the failure for example Failed to connect to remote host NA appears in both the Remote Implementation Class UID and Remote Implementation version and the list of services is empty The results of the communication between entities can be printed or saved To save select File gt Save as or click Save To print select File Print or click Print 4 4 2 Storage page Attributes List buttons If the focus of the window is in one of the destinations in the storage destination list only Add New is enabled
26. 1 This terminology is partly a remnant of the DICOM Standard DICOM specifies Information Object Definitions IOD s as being composed of modules Each module contains attributes Attributes can be reguired optional or only reguired under certain conditions conditional attributes Conditional attributes are always specified along with a condition Storage list Edit button To change information of one of the destinations attributes that is already in the storage attributes list perform the following steps 1 Select the attribute to be changed the line is selected Click Edit The Modify Tag window appears 3 Enter the new information and click OK The changes appear in the storage attributes list SOREDEX 207633 rev 2 207633 rev 2 4 Configuring DICOM Storage list Delete Button Allows an attribute to be deleted from the storage attributes list To do this Select the attribute to be deleted the line is selected Click Delete A delete confirmation message appears Click OK to delete the attribute 4 4 3 Storage Commitment settings The Storage Commitment feature can be enabled or disabled with the check box control Storage Commitment IV Use Storage Commitment Local Application Entity Title Pacs Local Port Number 106 Advanced Automatic delete for committed images no automatic delete em When enabled both the storing of images and requesting commitme
27. 1111111111 THEM LOL d v uv C u B BN MI E 2 ZE E 22232282823223282 22 2 2 2 2 22 22 ardada gasio ai Sani so oN oN Coma moy Wo a ORY l m OY oy ORY oN Hug LE TA bwon 74 panggeng ON XI sur faeces veg awe Sq ww o xumQ pee Wu srupeosro SOREDEX 2 207633 rev 2 Software installation 2 1 Software installation NOTE Do not install any of the software components to external hard disks 1 2 16 Insert the software DVD into the DVD ROM The installation program starts automatically If the installation program does not appear double click the SCANORASetup exe file on the DVD to start the software installation Follow the on screen instructions to install the software NOTE Depending on the operating system one or more reboots of the computer is needed and or pompted during the installation process Observe automatic continuation on installation after each reboot Initialization screen Preparing to Install Wait for the package to be extracted Scanora 5 0 1 InstallShield Wizard Preparing to Install Scanora 5 0 1 Setup is preparing the InstallShield Wizard which will guide you through the program setup process Please wait Extracting ScanoraPac
28. 7633 rev 2 207633 rev 2 5 Software database 5 4 Restoring database to a new installation and or location NOTE This procedure has to be applied whenever MS SQL Server database has been re installed Otherwise the new database installation does not read any of the existing data or images but is running the newly created empty database 5 4 1 How to restore a database to another installation or new location NOTE f you use 32 bit SQL Server in 64 bit Windows do a following modification into BackupDB bat before executing it Replace instance of Program Files with Program Files x86 in OSQLEXE definition NOTE f you use 32 bit SQL Server in 64 bit Windows do a following modification into ImportDB bat before executing it Replace instances of Program Files with Program Files x86 in OSQLEXE and SQLCMD definitions NOTE n Windows 7 run the files BackupDB bat and ImportDB bat in command line opened with Run as administrator MS SQL Server 2005 Express Workgroup Standard Enterprise Edition supported If you already have an up to date backup of the whole image folder ScanoraData and you have a matching pidbmsde dat file there in the Backup folder skip step 1 1 Make backup from the existing database source by running the backup batch file location e g C Program Files SCANORA Database Tools BackupDB bat Username Password admin admin by default 2 Make a backup of the image folder e g C Scano
29. Corp NOTE Refer Chapter 1 4 for details about service packs SOREDEX 11 1 Introduction 12 SOREDEX 207633 rev 2 2 Software installation 2 Software installation The software can be used as a standalone system or in a network environment The software system components Client basic software with DICOM option Database If the software is installed to a network environment of several computers the patient and image database can be shared and used from different workstations 2 0 1 Standalone system In standalone system all system components are installed to the same workstation connected to the X ray device 2 0 2 Network environment In network environment the software system components can be divided to several workstations M Modality workstation for image capturing Client Common Image capturing DICOM option Viewing workstation s Client Common DICOM option 3D image viewing software W Database workstation Database Common Database engine If you have existing MS SQL server see chapter 5 1 Installing the software database to existing MS SQL server NOTE nstallation is possible only with Administrator user rights In case of problems contact the system administrator 207633 rev 2 SOREDEX 13 2 Software installation NOTE Configure network with sufficient access rights and priviledges NOTE n a case of misconfigured DNS server or absence of a loca
30. ENGLISH SCANORA 5 0 Installation Manual 207633 rev 2 Copyright Manufactured by Code 207633 rev2 Date 10 August 2011 Document code D507636 rev 2 Copyright 08 2011 by PaloDEx Group All rights reserved Windows is trademark of Microsoft Corporation in the United States of America and other countries Pentium a registered trademark of Intel Corporation DIGORA Optime is a registered trademark of SOREDEX Documentation trademark and the software are copyrighted with all rights reserved Under the copyright laws the documentation may not be copied photocopied reproduced translated or reduced to any electronic medium or machine readable form in whole or part without the prior written permission of SOREDEX The original language of this manual is English SOREDEX reserves the right to make changes in specification and features shown herein or discontinue the product described at any time without notice or obligation Contact your SOREDEX representative for the most current information 0537 SOREDEX Nahkelantie 160 P O Box 148 FI 04300 Tuusula FINLAND Tel 358 10 270 2000 Fax 358 9 701 5261 For service contact your local distributor Table of Contents LEM riis LG ON a src ce c cence te dese ce O NANA NE RV AQ 1 tI General O ON A V TA isa nds ibt als 1 1 2 Manufacturer s Ilabilibya iioii A nA NJE Ne bate 2 1 3 Te m 2 1 4 SSYSLOMTMOQUITEINIG INS
31. MANAGEMENT AUTOMATICALLY lt 1 USE PRACTICE MANAGEMENT 1 PATID lt 00000 PATLNAME 0 PATMNAME 0 PATFNAME 0 PATSOCSEC 0 SOREDEX 207633 rev 2 10 Using practice management interface PATBD 0 PROVIDER1 0 PROVIDER2 0 ADDRESS1 0 ADDRESS2 0 CITY 0 STATE 0 ZIP 0 HOMEPHONE 0 WORKPHONE 0 FAX 0 EMAIL1 0 EMAIL2 0 Some PMS software that uses previous versions of the software might reguire that USE PRACTICE MANAGEMENT is permanently set by the user to 1 and that CLEAR PRACTICE MANAGEMENT AUTOMATICALLY 0 It is recommended that the PMS application sets both USE PRACTISE MANAGEMENT 1 and CLEAR PRACTISE MANAGEMENT AUTOMATICALLY 1 The software can read patient information from any ini file if the following line is added to PracticeManagementlnterface section BRIDGEFILE LOCATION OVERRIDE ini file ini 207633 rev 2 SOREDEX 109 10 Using practice management interface 10 2 How to use SCANORA ini Set CLEAR PRACTICE MANAGEMENT AUTOMATICALLY 1 if the PMS software automatically sets USE PRACTICE MANAGEMENT 1 Otherwise set the key to 0 To add a patient Set USE PRACTICE MANAGEMENT 1 Set PATID to a patient ID that does not exist in the software database yet Fill in the patient data fields Re start the software To alter patient information Set USE PRACTICE MANAGEMENT 1 Set PATID to match the patient whose information
32. Modify and click Next See already installed features in the Select Features dialog Add features by selecting the needed features Click Next InstallShield Wizard may ask Do you want to reconfigure external database selection Click No if you continue using the same database as before Click Yes if you change the database See chapter 5 3 Database backup and restore If you are adding a Database restart your computer Select Yes want to restart my computer now and click Finish Re log into Windows using administrator rights If you are adding other features than Database maintenance is complete Click Finish SOREDEX 207633 rev 2 8 Uninstalling 8 1 Uninstalling the software To uninstall the software select Start Settings gt Control Panel Double click Add or Remove Programs Vista Programs and Features select SCANORA and click Remove Vista Uninstall Follow the instructions on the screen If older versions of the software has been installed do not remove the software before verifying that the software is working and the converted database can be used The software uninstallation leaves directories on the hard drive and saves the database and images Uninstallation is for removing the software only The software uninstall does not remove any device drivers such as PCI drivers CAUTION Connection between all images and patient data is lost when the software with the database is uninst
33. OREDEX 65 4 Configuring DICOM 66 4 7 Storage SCP Storage SCP page The Storage SCP page allows the storage parameters to be defined The service is used when a remote DICOM application sends the images to the software The software works as Storage Service Class Provider SCP to the remote system Define the software storage service application entity title and TCP port number on the Storage SCP page NOTE Do not use the same AE Title and Port numbers for Storage SCP and Storage SCU in chapter 4 4 3 services Also port number must not be greater than 65535 DICOM settings E General Worklist Storage Print Query Retrieve Storage SCP Local DICOM parameters Local Application Entity Title SCANORA_DICOM Local Port Number 105 File Folder Filename C Documents and Settings All Users Application D Browse Click or Apply to save the configuration parameters Temp File Folder The folder on the local hard drive where the retrieved images are saved temporarily before saving them to database can be configured here Storage SCP page Advanced button The Log Files and Performance pages provide parameters for adjusting the low level settings of the DICOM network services There are similar settings for all SOREDEX 207633 rev 2 207633 rev 2 4 8 4 Configuring DICOM the DICOM network services See chapter 4 8 Log File and Performance Settings Log File and Performan
34. Restore from the software Manager dialog To restore an archive from another path than the default click Restore from S Restore Archives Archived Volumes Volume Label CD ROM 650 E SC_0001 2 Select the archive to be restored and click Restore Confirm Object Restore x Are you sure you want to restore selected object 3 Click Yes 4 After clicking Restore from browse the directory for archives 5 Select a folder and click Yes SOREDEX 95 9 Software Manager 96 9 3 Images 9 3 1 Remove archived NOTE Removing archived images can be done automatically after archiving by checking the Remove images from image folder after archiving box on the Create Image Archives dialog Previously archived images can be removed from the server to free up more storage space Select the removal criteria between 0 to 12 months of time during which the patient s images have not been reviewed To remove the archived images from the patient image folder select Remove achieved from the software Manager dialog 1 Select the appropriate time and click Start x Remove images if Patient data or images have not been edited for last El M month s Start Close 2 Click Yes to start removing the archived images Remove Archived Images xi Are you sure you want to start remove archived images SOREDEX 207633 rev 2 207633 rev 2 9 Software Manager 9 3 2 Settings Select PNG or JPG
35. a event e g Snapshot Button Pressed event When the Intra camera s snapshot button is pressed the software retrieves an image automatically 1 Open Scanners and camera properties in the Control Panel Select your Intra Camera from the devices list and click Properties Scanners and Cameras Properties 2 x Devices 28 The following scanners cameras are installed DM USB 2 0 Logitech ClickSmart 510 Add Remove Troubleshoot Properties Cancel 2 Select Events Tab DXM USB 2 0 Properties 2 General Events Color Management DXM USB 20 Camera events O Bi DxM Still Image Application O Bl imaging 7 j Photoshop Elements Disable device events Cancel Apply SOREDEX 37 3 Driver installation 38 3 Select New Picture Reguested from the Camera Events list and Enable SCANORA option from the lower list 4 Change the Camera event to Snapshot Button Pressed and Enable SCANORA option 5 Before the configuration is valid reboot your PC NOTE f the Events tab is not displayed then this feature is not available for the selected Intra Camera SOREDEX 207633 rev 2 4 Configuring DICOM 4 Configuring DICOM 207633 rev 2 Before using the software DICOM features the DICOM option must have been installed and the system should be configurated NOTE The software DICOM is a licensed feature A DICOM license key must have been given in e
36. abase tables Are you sure you want to continue is shown Click Yes Select or enter the database server where remote the software database resides e g enter the value under key hostname from server s DataSource ini and click Next default location of DataSource ini in the server is C ScanoraData Client Wait while Microsoft SQL Server 2008 database engine is being uninstalled When restart is suggested select Yes want to restart my computer now and click Finish Log on to Windows using an account with administrator rights to finish maintenance SOREDEX 207633 rev 2 207633 rev 2 5 Software database 5 2 2 Changing database location by modifying ODBC alias Client computer is configured to use other than local database and the local database is kept installed although the software client is no longer using it 1 7 Go to Control Panel Administrative Tools Data Sources ODBC Select System DSN tab Select SCANORA and click Configure Modify the Server field to correspond with the new database location Change local SCANOR A to SERVER SCANORA or you can use the drop down menu which shows all available SQL Servers When the new SQL Server is written in the Server field click Next Select With SQL Server authentication using a login ID and password entered by the user Also check Connect to SQL Server to obtain default settings for the additional configuration opt
37. alled 207633 rev 2 SOREDEX 91 8 Uninstalling 92 SOREDEX 207633 rev 2 9 Software Manager 9 Software Manager The software Manager is used to archive images restore archives alter image saving format define data directory images location manage users schedule backups manage trash and logs 9 1 Login The software Manager can be launched from Start gt Programs gt SCANORA Tools gt Manager The software Manager is password protected to prevent unauthorized usage Manager login User name Password Enter the user name password and click OK Default user name is admin and password is admin S Scanora Manager Logged in File Help SCANORA Manager Archive Images Database Create O Remove archived User management Restore O Settings Database backup Licence Location Trash O Exit O Report Logs EJ SOREDEX 207633 rev 2 SOREDEX 93 9 Software Manager 94 9 2 Archiving To release hard disk storage space on the server the unused images can be copied or moved to an archive media The information and scout images of these images remain in the database allowing easy retrieval whenever it becomes necessary to view any of the archived images 9 2 1 Create archive 1 To archive images select Create from the software Manager dialog S Create Image Archives Specify media and temporary archival folder Maximum size of media Me
38. as the saving format Select 60 100 guality for JPG Compressing images may decrease the image guality Image settings x gt File format and quality Modality File Format Image Quality Panoramic png v Quality Cephalometric png v 1 Juality zl Intraoral Photographic 9 3 3 Image folder location NOTE Do not use drive mapping when changing the data directory The software database backup will not work when a mapped network drive is used to access the ScanoraData folder If you have a network installation please only use an UNC path to define the data directory location in the software Manager 1 To change data directory images select Location from the software Manager dialog S Define data Directory Data Directory C ScanoraD ata Browse Browse the main directory for the images If you have network installation then use UNC Path e g server cvdata All files and subfolders from old image directory shall be moved manually to the new image directory 2 Create a new data directory and share it if network installation 3 Copy all files and subdirectories from main directory e g ScanoraData to the new data directory 4 Browse the new data directory and click Save SOREDEX 97 9 Software Manager 98 NOTE Be sure that the software is not used when changing the data directory 9 3 4 Report Exposure statistics 1 To create an exposure statistic
39. ce Manager File Action View Help OBE PALODEX 2251919 Computer Disk drives Display adapters Intel R 829456 Express Chipset Family Intel R 82945G Express Chipset Family DVD CD ROM drives Floppy disk controllers JB Floppy disk drives Human Interface Devices IDE ATA ATAPI controllers amp IEEE 1394 Bus host controllers 5 Keyboards Y 5 Mice and utluer pointing devices BB Network adapters E 4 Other devices Multimedia Audio Controller 5M Bus Controller PaloDEx Group imagng devices ti 9 Ports COM amp LPI Update Driver 4f Processors Disable Sound video and game Uninstall Storage volumes g System devices Scan for hardware changes Universal Serial Bus zon Properties 4 Click Update Driver 5 Select nstall from a list Click Next Hardware Update Wizard Welcome to the Hardware Update D Wizard This wizard helps you install software for II Serial link PCI driver If your hardware came with an installation CD or floppy disk insert it now What do you want the wizard to do O Install the software automatically Recommended Install from a list or specific location Advanced Click Next to continue SOREDEX 207633 rev 2 207633 rev 2 3 Driver installation 6 Select Don t search Click Next Hardware Update Wizard Please choose your search and installation options o
40. ce Settings The Log File Page allows the configuration the database the error log file or the storage service log file destinations and parameters to be changed Configuration Database field Allows the database name Data Source Name and location Filename to be changed Key in the specified path directly or click Browse and select the reguired name and location Write ODBC When the ODBC check box is selected a new DSN entry is to be inserted into the system DSN ist Refer to ODBC and Microsoft Windows documentation for details Error Log File field Allows the errors log file name and its maximum size in bytes to be selected Storage Service Log File field Allows the Storage Service message log file to be selected and configured The log file name maximum size the line length and log message levels are configurable x Log Files Performance Error Log File Filename ComponentsiStorage SCP Errors lor Browse Maximum size lines 500 Activity Log File Filename C Documents and Settings All UserslA Browse Maximum size 1000 ka Use error log file li m Message Log File Filename C Documents and Settings All Users 4 Browse Maximum size lines 100000 E Line length 78 Log Messages Levels Blank fill log file m v Error level Backup old log file p 4 Warning level Info level z Historical log files 1 SOREDEX 67 4
41. cheduled Procedure Step Description To Study Description Requested Procedure Description To Study Description Study date time use current date and time z The DICOM Modality Worklist Server allows information about patients to be obtained from the Hospital Information System The software supports the Modality Worklist Service as a Service Class User The Modality Worklist Service Class Provider is a program which purpose is to provide information to the Modality Worklist Service Class User Worklist Page allows a connection to the Modality Worklist Service Class Provider SCP to be configured 4 3 1 WorkList SCP Box AE Title This option specifies the Application Entity Title for the SCP application The AE Title is a characters string with a maximum length of 16 characters The AE Title is a DICOM name for a DICOM Modality Worklist Service Class Provider SCP which can receive DICOM queries from the software Host Name Is the remote host name or its IP Address For example 10 1 1 0 SOREDEX 43 4 Configuring DICOM 24 Port Is the TCP port on which the remote DICOM system listens for connections The default DICOM port number is 104 Obtain from the hospital administrator Polling interval sec Specifies the polling interval in seconds the software makes gueries to the Modality Worklist SCP If O seconds is set here no polling is done The user has to update the contents of the worklist dialog w
42. ck Edit 3 The Edit Printer Properties window appears Enter new printer information 4 Click OK to accept the changes The destination information in the printer destination window is updated Print page Delete button Delete a printer from the print list 1 Select the printer to be deleted Click Delete A delete confirmation message appears Click Yes to delete the printer Print page Advanced button The Log Files and Performance pages provide parameters for adjusting the low level settings of the DICOM network services There are similar settings for all the DICOM network services See chapter 4 8 Log File and Performance Settings Print page Verify button Verify DICOM printer connection 207633 rev 2 SOREDEX 59 4 Configuring DICOM 4 5 2 Print page Attributes List buttons With the attribute list buttons you can edit the printer default settings DICOM settings General Worklis Storage Print Query Retieve Storage scp Printer Name AE i LE Address Port Number Module Type pfe vale Image Display Format Basic Film Box mm if empty 20100030 Annotation Display Format ID Basic Film Box Replace if empty 20100040 Film Orientation Basic Film Box Replace if empty PORTRAIT 20100050 Film Size ID Basic Film Box Replace if empty 20100060 Magnification Type Basic Film Box Replace if empty CUBIC 20100080 Smoothing Type Basic Film Box Replace if empty 1 20100100 Border Den
43. dia type CD ROM 650 Temporary archival folder Volume label SC 0 o Capacity 0 MB Used 0 MB Free 0 MB Search for non active patients Patients to be archived Patient data or images have not been edited for last 3 Z monthis Last name First name Number Size MB Last name First name Number Size MB Select gt lt Remove Select All gt lt Remove All Total size OMB Total size OMB Remove images from image folder after archiving Start Close Select media type for archiving Select the temporary archival folder Define the time for inactive patients For example if you select inactive patients or data within the past six months the program offers all images of those patients to be archived Select the patients whose images you want to archive Also select if you want those images to be removed from the patients image folder on the hard disk Otherwise the archived images are shown as archived images in the patients image folder To start the archiving click Start Archive operation creates archive folders SCANORA xxx in the temporary archival folder To burn archived images to DVD ROM use DVD disk software and burn SCANORA xxx folders to DVD NOTE Store the software installation and archive DVD s very carefully SOREDEX 207633 rev 2 207633 rev 2 9 Software Manager 9 2 2 Restore archive 1 To restore the archive select
44. ee hand Angle Rectangle Circle Arrow Region of Interest tools Implant tools Drag or Erase graphics Edit graphics Save graphics NOTE CB3D 3D images require 3rd party viewing and or planning software Length Calibration Angle Free Angle NOTE CB3D 3D images require 3rd party viewing and or planning software MS Windows compatible printers DICOM Printers SCANORA DICOM Multi image printing Free print layout design Image information printing SOREDEX 207633 rev 2 207633 rev 2 1 Introduction Image archiving SCANORA Manager application Image dynamics grayscales 12 bit 4096 capture 16 bit 64k process 8 handling 8 bit 256 display Image storage mode 16 bit enhanced File formats PNG 16 bit JPG 12 bit File compression PNG lossless JPG 100 60 guality Typical file size Panoramic About 2 4 MB PNG 16 bits Cephalometric 3 5 MB PNG 16 bits Intra DIGORA Toto 3 5 MB PNG 16 bits CB3D 60 350 MB Intra DIGORA Optime 0 3 2 MB PNG 16 bits Import Export file formats BMP D32 PNG JPG TIFF DICOM JPEG 2000 MNG SOREDEX 1 Introduction 1 6 The software DICOM SOP Classes SOP Class Name Verification Verification Service Class DICOMDIR Basic Directory Storage SCU Digital X ray Image Storage for Presentation Digital X ray Image Storage for Processing Digital Intra oral X ray Image Sto
45. ent root Level PATIENT VR 0010 0020 String 0010 0010 String 0008 0052 String PATIENT r C Find Request Value r C Find Response Tag Caption 0010 0020 String Patient ID 0010 0010 String Patient name 0008 0054 String Retrieve AE Title gt z z Add Edit Remove The Advanced window shows default patient search criteria normally these can be left empty 4 6 1 Query options Editing default Query Retrieve messages Module Patient Root level r From the module and level scroll boxes choose different types of query levels In these boxes the following information can be found Module Level Patient Root Patient Study Series Image Study Root Study Series Image SOREDEX 63 4 Configuring DICOM 64 Add Edit and Remove buttons Click Add to increase the items in one of the lists reguest or response The following dialog appears which allows relevant information to be entered into the fields Tag dialog x Tag VR String i Value cem Remember that a Tag is usually written as an ordered pair of two byte numbers The first two bytes are sometimes called a group number with the last two bytes being called an element number e g 0010 0010 or 0038 001C The VR or Value Representation can be thought of as the
46. er size before DICOM application stores the data or passes it Setting higher values for this option increases performance Send Buffer This option sets the TCP IP send buffer size Higher values for this buffer increases the network performance of the tool kit for client SCU applications This value is larger than the PDU max length 4 9 Glossary ACR American College of Radiology Initiated the DICOM standardization effort in the early 80 s ACR NEMA Predecessor of the DICOM standard defined by the ACR and NEMA two versions were defined 1 0 and 2 0 AE Application Entity a software process which implements DICOM Most implementations use multiple AE s when implementing multiple Service Classes Attribute Attributes are the components of an information object definition 100 describing its properties DICOM Digital Imaging and Communications in Medicine standard IOD Information Object Definitions MergeCOM 3 Merge Technologies Inc provided toolkit performing low level DICOM communication Modality Acquisition system such as a CT MR US NM CR NEMA National Electrical Manufacturing Association 70 SOREDEX 207633 rev 2 207633 rev 2 4 Configuring DICOM PDU Protocol Data Unit a packet that is created at the DICOM lower level protocol SCP Service Class Provider SCU Service Class user SOP Service Object Pair TCPIIP Transmission Control Protocol Internet Protocol
47. estination to be deleted from the destination list To do this 1 Select the destination to be deleted the line is highlighted Click Delete A delete confirmation message appears Click Yes to delete the destination Storage page Edit button Allows the destination information in the storage destination list to be changed To do this 1 Select the destination to be edited the line is highlighted 2 Click Edit 3 The Edit Destination window appears Destination Title 5 _5 IP address 10 0 0 2 Port 104 4 Edit the destination information 5 Click OK to accept the changes The destination information in the storage window is updated Storage page Advanced button The Log Files and Performance pages provide parameters for adjusting the low level settings of the DICOM network services There are similar settings for all the DICOM network services See chapter 4 8 Log File and Performance Settings In addition to the settings common to all services there are following Storage SCU specific settings Retry count The number of retry attempts to made if the storing of an image has failed Use 0 to disable the retrying SOREDEX 51 4 Configuring DICOM 52 Retry interval The time period in minutes that is waited between the retries Storage page Set as Default button Allows the default destination to be set if there are more than two destina
48. ev 2 1 Introduction 1 5 The software specifications APPLICATION SOFTWARE PRODUCT NAME SCANORA Image acguisition modalities SCANORA 3D DIGORA Optime DIGORA Toto CRANEX D CRANEX 3D CRANEX Novus DIGORA PCT TWAIN compatible scanners and digital cameras Video acquisition devices VfW format B WDM format Patient database Microsoft SOL Server 2008 R2 Express Workgroup Standard Enterprise Edition Image storage Local or network Password security Yes Image appearance Instantly on monitor Imaging procedures pan ceph See corresponding Device s User Manual Imaging procedures intraoral Series Mount exposure Single exposure Imaging procedures pan ceph See User Program Chapter in CRANEX D CRANEX Novus and DIGORA PCT User Manual Imaging procedures 3D See SCANORA 3D User Manual CRANEX 3D User Manual SOREDEX 1 Introduction Image processing Brightness 8 Contrast Zoom Move Noise Reduction Edge enhancement Embossment Invert Mirror Rotate Sharpen Unsharp mask Pseudocolor Isodensity color Optimize contrast low medium high Gamma correction adjustments Egualized histogram logarithmic histogram linear histogram NOTE CB3D 3D images require 3rd party viewing and or planning software Overlay graphics Measurements Image Printing 2D modalities only Text Line Fr
49. ev 2 2 Software installation 11 Database workstation only Database tables location if Database engine is selected Choose Destination Location Select a destination folder for database tables and click Next For 32 bit platforms Default destination is C Program Files SCANORA Database For 64 bit platforms Default destination is C Program Files x86 SCANORA Database Choose Destination Location setup will install file C Program Files x86 Scanora Database Browse I SOREDEX ostali lt Back Neo o Database media files location if Database is selected Choose Destination Location Select a destination folder for database images and click Next Default destination is C ScanoraData C NScanoraDatas S m A dex Cene 207633 rev 2 SOREDEX 21 2 Software installation 22 Note For the system to work correctly the Database tables and Database media files must be located in the same computer Workstation not having database Database connection configuration in the workstation connecting to a remote database Select or enter the database server where remote the software database resides e g enter the value under key hostname from server s DataSource ini default location of DataSource ini in the server is C ScanoraData Client Scanora 501 InstallShield Wizard Select Database Server Select da
50. following table shows allowed the software versions for different SOREDEX imaging modalities x tested combinations with Windows Professional 32 bit y lt tested with Windows 2000 XP Professional 32 bit and Vista Business Vista Enterprise Vista Ultimate 32 bit z tested with Windows Professional 32 bit Vista Business SP2 32 bit Vista Enterprise SP2 32 bit and Vista Ultimate SP2 32 bit b tested with Windows Professional 32 bit Vista Business 32 bit 64 bit Vista Enterprise 32 bit 64 bit and Vista Ultimate 32 bit 64 bit Windows 7 Professional 32 bit 64 bit Windows 7 Enterprise 32 bit 64 bit Windows 7 Ultimate 32 bit 64 bit c tested with Windows Vista Business 32 bit 64 bit Vista Enterprise 32 bit 64 bit and Vista Ultimate 32 bit 64 bit Windows 7 Professional 32 bit 64 bit Windows 7 Enterprise 32 bit 64 bit Windows 7 Ultimate 32 bit 64 bit SCANORA DIGORA CRANEX CRANEX CRANEX DIGORA DIGORA DIGORA 3D Optime Novus D 3D Toto Vidi PCT 20 x vy MN Ma ha a a 3 1 2 2 2 2 3 2 2 2 2 2 2 2 2 4 2 b b b b 4 3 b b b b b b b 5 0 b b b b C b b b 207633 rev 2 Windows 2000 Windows XP Professional and Windows Vista Business Windows Vista Ultimate Windows Vista Enterprise Windows 7 Professional Windows 7 Ultimate Windows 7 Enterprise are registered trademarks of Microsoft
51. ftware database 86 SOREDEX 207633 rev 2 6 Upgrading the software 6 Upgrading the software 207633 rev 2 6 1 WARNING Before you start upgrade back up database and images NOTE Before you start upgrade update the latest service pack for the computer operating system Upgrading the software from version 3 1 or newer 4 Insert the software DVD into the DVD ROM 2 The installation program starts automatically If the installation program does not appear double click the SCANORASetup exe file on the DVD to start the software installation 3 Follow the on screen instructions to install the software 4 Initialization screen Preparing to Install Wait for the package to be extracted Welcome to the InstallShield Click Next License Agreement Read the software license and click Yes 7 Start copying files Verify the selected features and folders and click Next to continue 8 Setup status dialog Wait until software files are upgraded 9 InstallShield Wizard Complete Restart the computer if asked and click Finish NOTE n the case of upgrade being done for an existing Network environment with Firewall enabled add a new Inbound Rule or Exception for the software File Service in the Database Computer Remember to update the correct path of SQL Server in the Inbound Rule or Exception also Refer the note related to Firewall in section 2 0 2 for more SOREDEX 87 6 Upgrading the sof
52. i i S cbe ee 3 1 5 The software specifications Dec Ra orto Alaa 7 1 6 The software DICOM SOP 10 1 7 The software compatibility table 11 2 Softwarenstallation i NIN AN 13 2 0 1 Standalone system cte o o ee Dele decus 13 2 0 2 Network environment cnc neo ed dioc 13 2 1 Software installation 16 2 2 Display settings for the software esee aaa 25 3 DriverinstallaHON iji ae obo ee ee ee 27 3 4 CRANEX D driver installation 2 eeeee en aaa nenne 27 3 1 1 PClaryer Upda a ee oe oc e ai oles 30 3 1 2 Uninstalling the en aac d Doc pe ee ara 32 3 2 Intraorabcameranstellatiglis 33 3 2 1 Video Format iei uen ee te pete eu Raed 34 3 2 2 Video Source dialog oce teste iet ege Sete ie aptus at 35 3 2 3 Video Input dialog tore px et tI ener be entes nei ec see es end nid agis 36 3 2 4 Link the software to Intra camera event 37 4 DUC OM morc 39 4 1 General PAGE xxvn enm Epio peat DA RATS Era ES 40 4 1 1 DICOM License NUMDEL coo di feed cot ree cot m x D o at 41 4 1 2 Retired Command Elemelite aed ai oe eo arii d de e t 41 4 2 SOP Class configuration
53. ing DICOM Log Files Performance PDU max length Priority Below normal gt r Timeouts Association reguest 30 E Association Response 15 E Connection 15 d Release 15 ri Write 15 mi Inactivity 15 Buffers Work buffer 28672 E Send buffer 29696 Receive buffer 29696 zd N PDU max length Maximum size of Protocol Data Units that can be sent or received by the software DICOM Timeouts box Allows various timeouts in seconds to be set If the application is running in a multi tasking environment the process is blocked during this waiting period and the system processor is available for other processes If all the timeouts are set to 0 this is equivalent to polling as DICOM returns immediately whether a message has been received or not Association Request The waiting time for association request or for the peer to shut down an association Association Response The waiting time for a reply to an associate request Connection The waiting time for a network connection to be accepted Release The waiting time for a reply to an associate release Write The waiting time for a network write to be accepted Inactivity The waiting time for data between TCP IP packets 207633 rev 2 SOREDEX 69 4 Configuring DICOM Buffers This box allows various buffers to be configured to improve performance Work Buffer This option sets the buff
54. ions and fill in a valid Login ID Password admin admin by default Click Next Click Next Finish and OK After both cases 5 2 1 and 5 2 2 client computer is configured to use the external software database SOREDEX 5 Software database 18 5 2 3 Changing Standalone database to Network database using Modify Client and database are installed on modality workstation and the database is not shared i e database has been installed without the Database sharing feature The standalone database is modified so that it is shared to network and clients installed on other computers are able to connect to it 1 Go to Control Panel Add or Remove Programs Programs and Features in Vista Select SCANORA and click Change Wait for the software Setup Maintenance program screen to load Select Modify and click Next Select Database sharing feature under Database title and click Next If license key is asked enter your license and click Next and Next When restart is suggested select Yes want to restart my computer now and click Finish Log on to Windows using an account with administrator rights to finish maintenance Now the database is shared to network and other client computers can be configured to use it See chapter 5 2 2 Changing database location by modifying ODBC alias SOREDEX 207633 rev 2 207633 rev 2 5 Software database 5 3 Database backup and restore Database backup and re
55. ith the Refresh button when needed This setting is not available in the Search from worklist SCP mode Refresh Timeout This value specifies the timeout that the application waits for the worklist service to finish the refreshing The value is given as seconds Search method If Refresh from worklist SCP mode is selected the manual refreshing of the worklist cause the worklist guery C FIND to be sent to the Worklist SCP This is the recommended option for cases where the C FIND operations are fast or the user wants full control of the refreshing If Refresh from local database mode is selected the manual refreshing does not send a Worklist guery but only reads the latest data from the local worklist database This local database has the results of the worklist polling done on the background Note make sure the polling is enabled This is the recommended option for cases where the C FIND operations take a relatively long time If Search from worklist SCP mode is selected the Worklist SCP is searched directly for worklist items using only the filters provided in the worklist search dialog There is no automatic polling but the C Find guery is sent only when the user initiates the search This mode is potentially the slowest but provides the most control for the user The Verify Button See the Storage Page in this manual for more information SOREDEX 207633 rev 2 207633 rev 2 4 Configuring DICOM 4 3 2 Search for wo
56. ither during the software client installation or in the software Manager application after the installation To perform the software DICOM configuration you need the following information this information is normally provided by the local network administrator Network configuration information for the software workstation Port numbers for DICOM configurations IP addresses AE titles for the software entities AE titles Port numbers and IP addresses for the needed DICOM devices Storage server Storage Commitment Printer Worklist Query retrieve The IP addresses port numbers and AE titles for all connections can be obtained from the hospital s ADP personnel amp suppliers NOTE Access to the DICOM configuration settings is allowed to administrator users only Either run the software explicitly with administrator rights or in Windows XP use an Windows user account that has administrator rights The DICOM configuration window The tabbed pages The DICOM configuration window includes a tabbed set up property page for each of the features selected when the DICOM addition was installed If all four features were selected there are six tabbed set up property pages These are General Storage Print Worklist Query Retrieve Storage SCP SOP Classes SOREDEX 39 4 Configuring DICOM 40 4 1 DICOM settings al SOP Classes Worklist Storage Print Query Retrieve Storage SCP The main c
57. kage msi mm Cancel SOREDEX 207633 rev 2 207633 rev 2 2 Software installation 5 Welcome to the InstallShield Click Next Tm 7 z a InstallShield Welcome to the InstallShield Wizard for Scanora 5 0 1 9 The InstallS 5 3 omputer To continu 6 License Agreement Read the software license and click Yes ROA SRE TECE OHM Scanora 5 0 1 InstallShield Wizard License Agreement PI ad I SOREDEX InstallShield SOFTWARE LICENSE THIS DOCUMENT IS A LEGAL AGREEMENT BETWEEN YOU AS THE lt LICENSEE gt 8 AND PALODEX GROUP OY THE lt LICENSOR gt GOVERNING YOUR RIGHT TO USE THE SCANORA SOFTWARE lt Software gt IF YOU AGREE TO BE BOUND BY THE TERMS AND CONDITIONS OF THE SOFTWARE LICENSE AND THIS PARAGRAPH PLEASE PRESS I Agree AT THE PROMPT BELOW IN WHICH CASE YOU AGREE THAT THIS AGREEMENT IS ENFORCEABLE LIKE ANY WRITTEN NEGOTIATED AGREEMENT SIGNED BY YOU IF YOU DO NOT CONSENT TO THE SOFTWARE LICENSE AND THIS PARAGRAPH PLEASE PRESS Canceb AT THE PROMPT BELOW IN WHICH CASE THE SOFTWARE WILL NOT OPERATE AND RETURN THE SOFTWARE AND THE ACCOMPANYING ITEMS TO YOUR PLACE OF PURCHASE FOR A REFUND 1 Subject matter of the Software License This Software License governs the use of the Software Software means the software product specified above including new versions or updates of the Software made generally available f you SOREDEX 17
58. l DNS server use the IP address in the file server configuration instead of hostname in the Database computer refer chapter 9 5 This should be done after the Database installation is completed and before the start of Client s installation NOTE In case the Firewall is enabled you may have to add new Inbound Rules or Exceptions for the following in the Database Computer The software file service i e FileServer exe SQL Server service i e sglserver exe SQL Browser service i e sqlbrowser exe SQL Server port i e port on which sglserver exe is listening SQL Browser port i e port on which sqlbrowser exe is listening The default path for the executables for above services File Server C Program Files x86 Scanora Database FileServer exe SQL Server gt C Program Files x86 Scanora Database MSSQL10_50 SCANORA MSSQL Binn sqlservr exe SQL Browser gt C Program Files x86 Microsoft SQL Server 90 Shared sqlbrowser exe As an example In Windows 7 operating system if the Windows Firewall is enabled you can add the inbound rules by navigating to Control Panel Windows Firewall Advanced settings Inbound Rules SOREDEX 207633 rev 2 2 Software installation The following shows an example of Windows Firewall inbound rules screen shot after the above inbound rules have been added LJ TPN lng PEPA pagay lang epo snopa 144411111111111
59. le click the display icon Select the Settings tab to make specific changes Windows may prompt to restart Windows for this change to take effect The recommended Windows display settings are Desktop area at least 1024 x 768 pixels Color quality Colors Highest 32 bit SOREDEX 25 2 Software installation 26 SOREDEX 207633 rev 2 3 Driver installation 3 Driver installation 3 1 CRANEX D driver installation NOTE Before installing a PCI driver the PCI board must be installed Refer to the instructions in the CRANEX Installation Manual When the PC is switched on for the first time after PCI board installation Windows recognizes the hardware changes and launches a wizard Follow the instructions on the screen to install the PCI driver NOTE The screenshots are from Windows 1 Windows recognizes the hardware changes Select nstall from a list Click Next Found New Hardware Wizard Welcome to the Found New Hardware Wizard This wizard helps you install software for PCI Device If your hardware came with an installation CD or floppy disk insert it now What do you want the wizard to do O Install the software automatically Recommended Install from a list or specific location Advanced Click Next to continue 2 Select Don t search Click Next Found New Hardware Wizard Please choose your search and installation options Rai A O Search for the best driver
60. lela Cancel Adjust e g the brightness contrast hue and saturation These alternatives vary according to camera manufacturer 3 2 2 Video Source dialog Open the Video source dialog by clicking Source Source x Stream Format r Video Format Compression Video Standard PAL Frame Rate 25 000 aj Frame Interval zl m Elip Horizontal P Frame Interval E Color Space Compression zl RGB 24 Output Size Quality 384 x 288 default v Cancel Apply Select the reguested dimensions for the camera window from the Output Size list Select the reguested color setting from the Color Space list It is recommended to use 24 bit RGB These alternatives vary according to camera manufacturer and country 207633 rev 2 SOREDEX 35 3 Driver installation 36 Input Crossbar r Input o Video SVideo In Current Input 0 Video SVideo In Related Pin Audio Line In Link Related Streams 3 2 3 Video Input dialog Click Input to open the window I xi r Output fo Video Decoder Out Related Pin 1 Audio Decoder Out Cancel Apply Select the used input video connector from the Input list S video is recommended SOREDEX 207633 rev 2 207633 rev 2 3 Driver installation 3 2 4 Link the software to Intra camera event If Intra Camera supports events link the software to the Intra camer
61. llation Memory RAM At least 1 GB 32 bit OS or 2 GB 64 bit OS Processor 2 GHz Pentium 4 or better Monitor VGA or higher resolution monitor DVD ROM DVD ROM drive Hard disk 8 GB free space Pan ceph images 4 GB 1000 panorama or cephalometric images DIGORA Optime 2 GB 1000 images DIGORA Toto Standard resolution mode 1 3 GB 1000 images High resolution mode 4 GB 1000 images SCANORA 3D CRANEX 3D 100 GB 1000 CB3D study Other software We recommend anti virus software be used for continuous file protection However the CPU must still be powerful enough to run multi tasks during image capture Backup Backup system and RAID 1 or RAID 5 disks highly recommended SOREDEX 1 Introduction NOTE f the audio card is installed speakers are needed to hear the signal NOTE n the case of installation being done in Windows Server 2003 it requires the Windows Server 2003 hotfix KB925336 before installation can be done Pentium is a registered trademark of Intel Corp Windows Vista Windows XP Professional and Windows 7 are registered trademarks of Microsoft Corp For safe and reliable system performance you need to arrange an appropriate backup procedure meaning that you regularly back up the system and store the labelled back up media in a safe place The end user is solely responsible for backing up all data SOREDEX 207633 rev 2 207633 r
62. m S O Search for the best driver in these locations Use the check boxes below to limit or expand the default search which includes local paths and removable media The best driver found will be installed Search removable media floppy CD ROM Include this location in the search a Cliniiewt DriversKPCIDr Don t search will choose the driver to install Choose this option to select the device driver from a list Windows does not guarantee that the driver you choose will be the best match for your hardware 7 Click Have Disk and browse a new PCI driver DdxDrv inf from the software version 3 1 0 or later DVD Click Next Hardware Update Wizard Select the device driver you want to install for this hardware ee g Select the manufacturer and model of your hardware device and then click Next If you have a disk that contains the driver you want to install click Have Disk Show compatible hardware Model 11 Serial link PCI driver amp This driver is not digitally signed Tell me why driver signing is important lt Back Next gt Cancel 8 The PCI driver is now updated Hardware Update Wizard Completing the Hardware Update Wizard The wizard has finished installing the software for Serial Link PCI Device Click Finish to close the wizard SOREDEX 31 3 Driver installation 32 3 1 2 Uninstalling the driver If the driver installation fails remove the dri
63. n dl make sure that the correct drive is selected below Cancel Copy manufacturer s files from m s Pom SOREDEX 207633 rev 2 207633 rev 2 3 Driver installation 6 Click OK Install From Disk Insert the manufacturer s installation disk and then OK CS make sure that the correct drive is selected below Copy manufacturer s files from GACIniVien Divers PCIDv v 7 Click Next Found New Hardware Wizard Select the device driver you want to install for this hardware NS Select the manufacturer and model of your hardware device and then click Next If you have a disk that contains the driver you want to install click Have Disk Show compatible hardware Model Serial Link PCI Device This driver is not digitally signed Tell me why driver signing is important lt Back Next gt Cancel 8 The PCI driver is now installed Proceed to software installation If the driver installation fails proceed to the chapter Uninstalling the driver Found New Hardware Wizard Completing the Found New Hardware Wizard The wizard has finished installing the software for Serial Link PCI Device Click Finish to close the wizard SOREDEX 29 3 Driver installation 30 3 1 1 PCI driver update Update the PCI driver as follows 1 Right click My Computer and choose Manage 2 Choose Device Manager 3 Right click Il Serial link PCI driver SOREDEX devices Devi
64. ndom access memory MB Megabytes GB Gigabytes CCD Charge coupled device DVD RW Digital Versatile Disc re writable PCl Peripheral Component Interconnect DAT Digital audio tape MOD Magneto optical drive USB Universal Serial Bus VfW Video for Windows a video format supported by the software Intraoral Camera interface SOREDEX 207633 rev 2 1 Introduction WDM Windows Driver Model a video format supported by the software Intraoral Camera interface WLAN Wireless Local Area Network 1 4 System reguirements Minimum system reguirements for the software client Operating System B Windows XP Professional OS SP3 32 bit B Windows Vista Business Ultimate Enterprise SP2 32 or 64 bit B Windows 7 Professional Ultimate Enterprise SP1 32 or 64 bit Windows Server 2008 SP2 32 bit Windows Server 2008 SP2 64 bit reguires installation of Desktop Experience Memory RAM At least 1 GB 32 bit OS or 2 GB 64 bit OS Processor 2 GHz Pentium 4 or better Hard disk 8 GB free space DVD ROM DVD ROM drive for installation Keyboard Yes Mouse Yes Network card 10 100 1000 Mb s Ethernet Monitor 19 or larger recommended capable of 1280 x 1024 resolution 24 bit color or better PCI slot PCI slot for CRANEX D capture card in CRANEX D acguisition PC USB port USB port for DIGORA Toto SOREDEX 1 Introduction CB3D additional requirements GPU g
65. nt for the images use the software Storage SCU Application Entity The details of this AE must be configured AE Title and Port number Contact the local system administrator to get these values NOTE Do not use the same AE Title and port number as in Storage SCP Automatic delete for committed images When the Storage Commitment feature is enabled an automatic image deletion can be defined Only the images that are successfully committed are affected by this feature If the patient is left with no images after the image deletion the patient is also deleted Log entry of the deletions will be made into the System Log see chapter System Logs All deleted images are put into the Trash see chapter Trash from where they can be either restored or permanently deleted The following options are available for automatic deletion no automatic delete delete immediately after commitment delete 12 hours after commitment delete 24 hours after commitment delete 48 hours after commitment SOREDEX 55 4 Configuring DICOM 56 NOTE Use this feature carefully since it removes captured X ray images from the software without user s explicit acceptance for each image and the images may need to be retrieved from the PACS if they are needed Storage Commitment Advanced Maximum retry count for failed Commitment attempts This parameter defines the number of retries to be made if the Storage Commitment attempt fails f
66. o activate the user management function Add and remove users To add a user click Add Select the name of the user from the list or click Add to create a new user Enter the information for the new user and click OK SOREDEX 207633 rev 2 207633 rev 2 9 Software Manager Set password for admin xj Old Password New password Four character minimum Confirm new password To change the password for user click Set Password Fill in the fields and click OK 9 4 2 Database backup Choose the schedule for automated backup of the Database tables NOTE This function does not create a backup of the images See Chapter 5 3 Database backup and restore Database Backup Timing xj Schedule backup Dayat 203000 25 Save Close Define the schedule and click Save Confirm Change x Are you sure you want to change backup timing No Click Yes SOREDEX 101 9 Software Manager 102 9 4 3 Trash Various objects that have been previously marked as deleted in the software can be permanently deleted from the database in the trash menu This means that the software user can not permanently delete any information unless the administrator empties the deleted information from the trash Select Trash from the from the software Manager dialog LT j x Objects to be deleted Trash Date Select All Restore Delete Close Select all All
67. objects can be selected for deletion Restore Deleted information can be restored for further usage Confirm Object Restore x Are you sure you want to restore selected object Confirm restore Delete Information is deleted permanently Confirm Object Delete Are you sure you want to delete selected object To confirm removal click Yes SOREDEX 207633 rev 2 207633 rev 2 9 Software Manager 9 4 4 System Logs To view user actions in the software select Logs from the software Manager dialog x Search Object User z Logs in the last 1 days Goki Action Logon Dae User WorkStation Action Object Description 2004 03 24 09 00 26 admin FIDCSEX0J Logon 2004 03 24 09 18 54 admin FIDCS8X0J Logon 2004 03 24 09 22 05 admin FIDCS8X0J Logon 9 4 4 1 Search logs It is possible to restrict search results with the following filters Object Action and number of last days Select Object where action is targeted as All Database Image Patient Study or User Select Action The following combinations are possible Object All All Actions Database Update Image Archive Capture Delete Hide Import and Restore Patient Delete and Hide Study Delete and Hide User Login and Logoff Define the number of days you want to look back for the software system logs If 1 is selected then today s logs are shown and if 2 is selected then today s and yes
68. ogram Files SCANORA ExeFile SCANORA executable for example C ProgramFiles SCANORA SCANORA exe SOREDEX 107 10 Using practice management interface 108 When starting the software the settings are read from the SCANORA ini configuration file It is allowed to run only one instance of the software on a computer at a time If starting the software while the software is already running no additional instances of the program are started However the already running the software reads the Practice Management Interface section of the SCANORA ini file and acts accordingly Finally the software sets all entries in the Practice Management Interface section to 0 The Practice Management Interface section in the SCANORA ini file is described below The mandatory fields are USE_PRACTICE_MANAGEMENT If set to 1 the software reads the Practice Management Interface section at startup and on activation and users are not allowed to change or add new patients manually from the software user interface CLEAR PRACTICE MANAGEMENT AUTOMATICALLY If set to 1 the software resets USE_PRACTICE_MANAGEMENT and the patient keys every time the software reads the SCANORA ini file If set to 0 the software does not reset to 0 the keys PATID Patient ID shall be unique and defined by PMS software Practice Management Interface PATBD defines date of birth which shall be formatted as defined in system regional settings CLEAR PRACTICE
69. onditions 3 1 You hereby expressly agree that Licensor and its software suppliers own throughout the world all right title and interest in the Software any copies thereof and all intellectual property rights contained or embodied therein including the ownership to any modifications or translations of the Software and that such ownership or rights shall not be transferred to you 3 2 With respect to any software of third party suppliers contained or to be contained in the Software you agree to the ownership of Licensor s suppliers hereunder and accept that Licensor s suppliers are direct and intended third party beneficiaries of this Software License with rights solely against you including without limitation on reasonable prior notice to and consent of Licensor the right to directly enforce and or terminate your license to use the Software Further you agree that Licensor s suppliers have no liability or obligations towards you arising out of or in connection with this Software License You agree to execute any such amendments to this Software License as may be required from time to time in order to comply with terms and conditions of any third party software suppliers 3 3 Your license to use the Software shall commence upon the execution of this Software License and shall thereafter remain in effect unless you fail to comply with the terms and conditions of this Software License including any amendments thereto Upon termination
70. onfiguration buttons After making configuration changes click Apply or OK at the bottom of the DICOM configuration window to accept the changes CON e W Apply button Click to save changes The DICOM configuration remains open Cancel button Changes are not saved and the DICOM configuration closes m OK button Click to save changes The DICOM configuration closes General page The General page gives an overview of the Local DICOM parameters DICOM settings x General woikiis Storage Print Query Retrieve Storage SCP r Local DICOM parameters Local Application Entity Title SCANORA DICOM Local IP address Local station name m DICOM by Merge Library version 25 1 License number Retired Command Elements Initiator name for command messages Receiver name for command messages Send Length to End 0000 0001 in command messages Send Recognition Code 0000 0010 in command messages Send Message ID 0000 0110 in command response messages Send Priority 0000 0700 in command response messages cesa mer SOREDEX 207633 rev 2 207633 rev 2 4 2 4 Configuring DICOM The Local Application Entity Title is the DICOM name for the software The name must be 1 to 16 characters in length letters A Z and or numbers 0 9 with no spaces Contact the hospital administrator to obtain the correct Application Entity Title AE title 4
71. or some reason Use 0 to disable the retry feature Retry interval for failed commitment attempts This parameter defines the wait time period between the retries Minutes are used Wait for commitment report in N ACTION Association Some Storage Commitment SCPs are able to send the Storage Commitment report within the same association as the Storage Commitment reguest This attribute defines the time period in seconds that the software Storage Commitment SCU waits for the report message Use 0 to always reguire separate association to be used for the Storage Commitment report Wait time for storage commitment report The time period in minutes that Storage Commitment SCU waits for Storage Commitment report after reguesting it After this time period expires the status of the Storage Commitment task goes either into Waiting for Storage Commitment Retry if the retrying is enabled and there are retries left or to Storage Commitment Failed Reports can still be received and they are processed even after this timeout has expired Delay between storage and commitment The time period that Storage Commitment SCU waits after Storage before sending the Storage Commitment request SOREDEX 207633 rev 2 4 Configuring DICOM 4 5 Print configuration Open this page for the first time after installation and see two empty lists 1 The Print Destination List 2 The Print Attributes List General Worklist Storage Print Que
72. otherwise duplicate the Software or any part thereof for any purpose or to allow any third parties to do the same without the prior written consent of Licensor Notwithstanding the above you may make one copy of the Software for back up purposes provided that such copy and the media thereof shall include the same copyright and other proprietary notices or legends included on the Software when it was shipped to you You agree not to remove any Software identification copyright notices or other notices or proprietary restrictions from the Software Confidentiality 5 1 The Software contains proprietary and confidential information of Licensor and its suppliers and is considered by Licensor and its suppliers to constitute valuable trade secrets You agree to hold the Software in confidence and protect the Software with at least the same degree of care with which you protect your own similar confidential information but in no event less than a reasonable standard of care You agree that your officers and employees shall protect the SOREDEX 115 11 Software license 116 confidentiality of the Software and all confidential and non public information relating thereto and shall not disclose such information to any third party This obligation of confidentiality shall survive the termination of the Software License 5 2 You agree not to decompile reverse assembles or reverse engineers the Software or otherwise attempt to derive source code
73. pliers shall have the right but not the obligation to undertake legal proceedings in a court of your domicile principal place of business or other appropriate court to i settle any issue or dispute arising out of or relating to monies due by you to Licensor ii protect or enforce any patent trademark copyright or other intellectual property right confidential information or trade secrets or iii proceed with litigation commenced by a third party 7 4 Judgment upon the award rendered may be entered in any Court having jurisdiction or application may be made to such Court for a juridical acceptance of the award and an order of enforcement as the case may be General 8 1 This Software License together with license terms of third party suppliers of Licensor if any constitute the entire agreement with respect to the subject matter hereof between you and the Licensor and supersedes all previous oral or written communications or agreements relating to the same Only a written instrument expressly agreed to by the parties hereto may modify this Software License 8 2 The failure of Licensor to enforce any provision of this Software License shall not be considered a waiver of any subsequent breach of that provision or as a waiver of any other provision hereof SOREDEX 117 11 Software license 118 SOREDEX 207633 rev 2
74. r confidential or other information for business interruption for personal injury for loss of privacy for failure to meet any duty including of good faith or of reasonable care for negligence and for any other pecuniary or other loss whatsoever arising out of or in any way related to the use of or inability to use the Software the provision of or failure to provide support services or otherwise under or in connection with any provision of this Software License even in the event of the fault tort including negligence strict liability breach of contract or breach of warranty of Licensor or any of its SOREDEX 207633 rev 2 207633 rev 2 11 Software license suppliers and even if Licensor or any of its suppliers has been advised of the possibility of such damages Applicable Law and Jurisdiction 7 1 This Software License to be construed governed by and interpreted in accordance with the laws of Finland excluding the UN Convention on Contracts for the International Sale of Goods 7 2 Disputes arising from or in connection with this Software License are to be settled by arbitration by one arbitrator The Board of Arbitration of the Central Chamber of Commerce of Finland shall appoint the arbitrator and the Rules of the said Board are to be followed in the arbitration proceedings The arbitration shall be held in Helsinki Finland and conducted in the English language 7 3 Notwithstanding the foregoing Licensor and its sup
75. raData INCLUDE ALL CONTENTS 3 Install the software database to the new computer destination and restart the computer when asked NOTE For the system to work correctly the Database tables and Database media files must be located in the same computer SOREDEX 81 5 Software database 82 4 Delete the whole Files folder under the image folder on the destination computer location e g C ScanoraData DB Files 5 Copy the database backup file pidbmsde dat from source your backup to the Backup folder on the destination location e g C ScanoraData Backup Replace existing pidbmsde dat if a file with that name already exists 6 Copy the whole Files folder including all files and subfolders from source your backup to destination e g C ScanoraData DB Files 7 In case the database backup is from the same software database version as the new database perform step A In case the database backup is from the older software database version than the new database perform step B A Run ImportDB bat location e g C Program Files SCANORA Database Tools ImportDB bat and enter Username Password admin admin by default B See Old Backup Importer instructions found in installation media under Tools OldBackupImporter to import a backup from SCANORA 3 0 0 12 or later to current version of the software 8 Reconfigure the database connection ODBC of the clients as explained in the
76. rage for Presentation Digital Intra oral X ray Image Storage for Processing VL Photographic Image Storage CT Image Storage Enhanced CT Image Storage Computed Radiography Image Storage Secondary Capture Image Storage Multi frame Grayscale Byte Secondary Capture Image Storage Multi frame Grayscale Word Secondary Capture Image Storage Multi frame True Color Secondary Capture Image Storage Storage Commitment SCP Storage Commitment Push Model Query Retrieve SCU Patient Root Find Patient Root Move Study Root Find Study Root Move Modality worklist SCU Modality Worklist DICOM Print SCU Printer SOP Class Basic Grayscale Print Management Basic Film Session Basic Film Box Basic Grayscale Image Box Basic Color Print Management Basic Color Image Box 10 SOREDEX SOP Class UID 1 2 840 10008 1 1 1 2 840 10008 1 3 10 1 2 840 10008 5 1 2 840 10008 5 1 2 840 10008 5 1 2 840 10008 5 1 2 840 10008 5 1 2 840 10008 5 1 2 8 1 2 8 1 2 8 1 2 8 40 10008 5 40 10008 5 40 10008 5 40 10008 5 5 Cn re rs rs rs en Cn Cn oo 1 2 840 10008 5 1 4 1 1 7 3 1 2 840 10008 5 1 4 1 1 7 4 1 2 840 10008 1 20 1 1 2 840 10008 5 1 2 840 10008 5 1 2 8 1 2 8 840 10008 5 840 10008 5 PRADA SARA IN 1 2 840 10008 5 1 4 31 gt gt 207633 rev 2 1 Introduction 1 7 The software compatibility table The
77. raphics card supplied with CB3D device requires one available PCl express x16 full length dual slot B Power supply for reconstruction GPU Minimum 500 watt power supply 6 pin x 2 supplementary power connectors WB Atleast 3 GB RAM B Intel Core 2 Quad 2 0 GHz or better B 1600 x 1200 monitor or better Other software We recommend anti virus software be used for continuous file protection However the CPU must still be fast enough to run multi tasks during image capture Other device Device to support archive and backup media Minimum system requirements for the software database and SQL Server Operating system OS B Windows XP Professional SP3 32 bit B Windows Vista Business Ultimate Enterprise SP2 32 or 64 bit B Windows 7 Professional Ultimate Enterprise SP1 32 or 64 bit B Windows Server 2003 SP2 32 bit Windows Server 2008 SP2 32 bit B Windows Server 2008 R2 SP1 64 bit B Windows Server 2008 SP2 64 bit reguires Windows Server 2003 hotfix KB925336 before CliniView installation SOREDEX 207633 rev 2 1 Introduction Supported SQL Server versions NM SQL Server 2005 SP2 32 bit x86 edition Express Standard Workgroup Enterprise WB SQL Server 2008 with SP1 32 bit x86 edition Express Standard Workgroup SQL Server 2008 R2 32 bit x86 edition Express Standard Workgroup reguires SP1 installation after SQL Server insta
78. rklist items by date Set the number of day s before and after today that are taken into account in worklist search Using values 0 and 0 here means that only worklist items scheduled for today are gueried from the worklist server This setting is not available in the Search from worklist SCP mode 4 3 3 Modalities Box Checking the modality boxes allows the chosen modalities to be retrieved from the Modality Worklist SCP Modality SOP Class Name DX Digital Radiography lO Intraoral Radiography PX Panoramic X Ray CR Computed Radiography XC External camera Photography CT Computed Tomography Other User defined modlity can be left empty in which case modality is not used as a search criteria Also several modalities can be defined Separated by a space This setting is not available in the Search from worklist SCP mode 4 3 4 Scheduled Station This option can be used to retrieve only the items scheduled for the specified workstation AE Title This setting is not available in the Search from worklist SCP mode 4 3 5 Worklist Page buttons Columns button Define the attributes and the order in which they appear in the Worklist window in the Set Columns dialog Click Columns and the Set Columns window opens The Set Columns window is divided into two lists 1 Hidden Attributes List 2 Shown Attributes List SOREDEX 45 4 Configuring DICOM 46 Set Columns x Attributes Hidden Attributes
79. ry Rettieve Storage sce IP Address Module Type Defaut vane a 20100010 Image Display Format Basic Film Box mem if empty 20100030 Annotation Display Format ID Basic Film Box Replace if empty 20100040 Film Orientation Basic Film Box Replace if empty PORTRAIT 20100050 Film Size ID Basic Film Box Replace if empty 20100060 Magnification Type Basic Film Box Replace if empty CUBIC 20100080 Smoothing Type Basic Film Box Replace if empty 1 20100100 Border Density Basic Film Box Replace if empty WHITE 20100110 Empty Image Density Basic Film Box Replace if empty 20100120 Min Density Basic Film Box Replace if empty 20100130 Max Density Basic Film Box Replace if empty 300 20100140 Trim Basic Film Box Replace if empty Add new Print Destination List To the Print Destination List add DICOM printers Print Attributes Tag List To the Print Tag List add settings for every DICOM printer e g media size 4 5 1 Print page Destinations AE Title IP Address Port Number Advanced Add new Edit Delete 207633 2 SOREDEX 57 4 Configuring DICOM 58 Print page Add new button Add a new DICOM printer by clicking Add new Edit Printer Properties Printer Name ICOM PRINTER AE Title PRINT_SCP TP address 10 0 0 3 Port Capabilities Basic Grayscale Print Management Basic Color Print Management 104 can Complete the fields as follow
80. s report select Report from the software Manager main view S Image Report Images between 18 4 2008 x and 18 4 2008 v Destination file name C Program Files Scanora Tools Manager Report ht Open Report when ready Internet Explorer used Settings Generate Close 2 the report parameters and click Generate to create a report Viewing report Open htm file e g Report htm with Internet Explorer C Program Files Tools Manager Report htm Microsoft Internet Explorer File Edit View Favorites Tools AN y gt Ig Search 3x Favorites Media di Address C Program Files Tools Manager F V Go Links B SupportCentral x 6 Exposure Statistics 2006 01 30 Pan Total 1 Ceph Lat Total 1 Date Range 2006 01 01 2006 01 30 Nude Dawe Mais Name ma z nova 1 2006 01 27 Ceph Lat Farmer Ted 20 12 6 85 1 2 2006 01 27 Pan Farmer Ted 13 Genented by 8 66 3 Manager 1 2 2 4 PaloDEx Group Oy 3 My Computer The report contains the following data Header Exposure statistics Report date e g SCANORA 2006 01 30 Total count of images by modality Date Range Image list with values Image Date Modality Patient name Exposure values and DAP value SOREDEX 207633 rev 2 207633 rev 2 9 Software Manager The image list is sorted by modality and image date Export Data The ea
81. siest way to export data is to use the clipboard as following Select Edit Select All Ctrl A from Internet Explorer Select Edit Copy Ctrl C Open third party software e g Word or Excel Select Edit gt Paste Ctrl V Make your own report It is also possible to make your own style sheet but XML skills are required Choose Style Sheet for a report Click Settings on Image Report dialog Browse or enter Style Sheet path and click Save The software Manager remembers the last used style sheet S Image Report Settings x Report Style sheet c Program Files Scanora T ools M anagerSStyleSheetsdefault eng xsl zo Save Close SOREDEX 99 9 Software Manager 100 9 4 Database 9 4 1 User Management User management makes it possible to define categories for different users and define passwords for each user Select User management from the software Manager dialog S User Management X Users must enter a user name and password to use Scanora Scanora users User Name Group ___ Name admin Administrator VTSystem Default VT System User tester Default tester Add Update Set Password Close Administrator category means that the user has rights to both the software and the software Manager Users in default category are entitled to start the software program only Mark the upper left corner t
82. sity Basic Film Box Replace if empty WHITE 20100110 Empty Image Density Basic Film Box Replace if empty 20100120 Min Density Basic Film Box Replace if empty 20100130 Max Density Basic Film Box Replace if empty 300 20100140 Trim Basic Film Box Replace if empty zi zal Edit Delete Apply Edit button Select the attribute in the list which is needed to be changed the line turns blue Click Edit Tag 20100110 Empty Image Density Module Basic Fim Box Type epxefemty H Default value BLACKI Check the correct default values from the printer documentation or hospital administrator Enter new information and click OK The changes appear in the Print Attributes list 60 SOREDEX 207633 rev 2 4 Configuring DICOM Delete button Delete an attribute from the print attributes list 1 Select the attribute to be deleted 2 Click Delete 3 A delete confirmation message appears 4 Click Yes to delete the print attribute 4 6 Query Retrieve configuration The Query Retrieve service provides a tool for search and retrieve of patients and images from image archives Query Retrieve page DICOM settings General SOP Classes Worklist Storage Print Query Retrieve Storage SCP Query Retrieve SCP Application Entity Title 5 IP address or host name 127 0 0 1 Port number 105 Application Entity Title for Move Service
83. ssors Disable Sound video and game Uninstall Storage volumes B System devices Scan For hardware changes Universal Serial Bus zon Properties 2 Click Add Remove Hardware in the control panel SOREDEX 207633 rev 2 3 2 207633 rev 2 3 Driver installation Intraoral camera installation The software supports image capturing with WDM Windows Driver Model and VFW Video For Windows WDM is recommended for the software Install the video capture card and the drivers supplied with your intraoral camera following the intraoral camera s installation instructions To enable intraoral camera capture select IntraCam in Tools Settings Installed devices Clicking Intraoral camera capture opens the intraoral camera window Click Settings to open the settings dialog To hide intraoral camera capture button de select IntraCam in Tools Settings Installed devices To achieve the best possible image quality it is recommended that the camera device is checked Click Settings to open the settings dialog Settings Video Format and Source mej maj Settings Device FootPedal Close after image snap 23 seconds f COM2 Disabled Capture Delay Delay 0 milliseconds Shortcuts Start Capture 4 Shift Control Snap Image F5 f Shift Control End Capture F6 Shift Control Normally the device is selected automatically
84. stalled installed from the options be O CRANEX D Pan Fiber optic cable only O CRANEX D Ceph Fiber optic cable only CRANEX D Pan Fiber optic serial cable CRANEX D Ceph Fiber optic serial cable SCANORA 3D DIGORA Toto ODIGORA Optime DIGORA PCT LJ VA P InstallShieid 10 License Agreement Read the Microsoft license and click Yes Ple MICROSOFT SOFTWARE LICENSE TERMS MICROSOFT DIRECTX END USER RUNTIME These license terms are an agreement between Microsoft Corporation based on where you live one of its affiliates and you Please read them They apply to the software named above which includes the media on which you received it if any The terms also apply to any Microsoft updates supplements Internet based services and support services for this software unless other terms accompany those items If so those terms apply BY USING THE SOFTWARE YOU ACCEPT THESE TERMS IF YOU DO NOT ACCEPT THEM DO NOT USE THE SOFTWARE If you comply with these license terms you have the rights below 1 INSTALLATION AND USE RIGHTS You may install and use any number of copies of the software on your devices 2 SCOPE OF LICENSE The software is licensed not sold This agreement only gives you some rights to use the software Microsoft reserves all other rights Unless applicable law S tu A A Install Shield 20 SOREDEX 207633 r
85. store utilities are installed under Tools folder in the software installation directory e g Program Files SCANORA Database Tools The backup of the ScanoraData folder including all subfolders can be made with any backup software and media type that the user has available NOTE This describes a procedure as an example to backup both the database tables and medical images Therefore ensure that all the ScanoraData contents fit in the backup media it can be up to several gigabytes The necessary backup software is supplied with the backup device e g Magneto optical tape drive 5 3 1 Making instant backup from the software database NOTE f you use 32 bit SAL Server in 64 bit Windows do a following modification into BackupDB bat before executing it Replace instance of Program Files with Program Files x86 in OSQLEXE definition NOTE It is highly recommended that all users are logged off the software database NOTE Running the backup restore batch files under the Tools directory could fail under Windows Vista operating system due to missing permissions to create files under the Program Files directory In such cases the problem can be circumvented by e g adjusting permissions or moving the Tools folder under some other directory 1 Run BackupDB bat located in the Tools folder mentioned in the beginning of the chapter In Windows 7 run file in command line opened with Run as administrator 2 Enter the administra
86. t File File Server Configuration In the File Server Configuration dialog change the IP or computer name to match the new computer name and then click Save 5 5 2 Modifying Datasource ini Modifying the Datasouce ini is essential to new clients that are installed after renaming the database computer Datasource ini is located at the folder ScanoraData ClientConfiguration File should contain the following lines Data Source hostname OLD_COMPUTER_NAME Scanora OLD COMPUTER NAME should be replaced with the new computer name SOREDEX 207633 rev 2 207633 rev 2 5 Software database 5 5 3 Modifying Already Installed Clients to Use New Database Computer Name NOTE This step must be done in every client computer To modify already installed clients to use new database computer open Control Panel and select Administrative Tools In the Administrative Tools open Data Sources ODBC and go to System DSN page Now select a system data source named SCANORA and click Configure Microsoft SQL Server DSN Configuration This wizard will help you create an ODBC data source that you can use to connect to SOL Server What name do you want to use to refer to the data source Name Scanora How do you want to describe the data source Description Which SOL Server do you want to connect to Server OLD COMPUTER NAMEYScanora v Replace the OLD COMPUTER NAME with the new one and click finish SOREDEX 85 5 So
87. tabase 5 The software installation program is now ready to start copying files Click Next 6 Click Finish to complete the installation and restart the computer NOTE n the case of Default log in to database doesn t work please authenticate manually message appearing during the installation press the OK button to continue and proceed with the installation NOTE Connection to the MS SQL Server in step 4 above may not work if the password contains special characters that case change the password to one without having special characters and then continue SOREDEX 15 5 Software database 76 5 2 Changing the software database location NOTE f content of local database needs to be moved see chapter 5 4 Restoring database to a new installation and or location 5 2 1 Changing database location by uninstalling local database using Modify This procedure removes the database from the local computer where the software client is installed If you do not want to remove the local database see chapter 5 2 2 Changing database location by modifying ODBC alias 1 Go to Control Panel Add or Remove Programs Programs and Features in Vista Select SCANORA and click Change Wait for the software Setup Maintenance program screen to load Select Modify and click Next Unselect Database feature and click Next A question If database is uninstalled all patient data is going to be deleted from the dat
88. tabase sen canora database resides E g enter the value 3 64 A A Tm MU au P NOTE Database path should be shorter than 58 characters NOTE n case of misconfigured DNS server or absence of a local DNS server use the IP address while entering the database server where remote the software database resides SOREDEX 207633 rev 2 2 Software installation 12 License Entry Enter the license key Click Next License Entry empty to use demo m After installation license can be I SOREDEX ceni 13 License User is presented with licensed features the license key grants Click Next ETSI TE License tion license can be modified using Scanora I SOREDEX Install Stiield 207633 rev 2 SOREDEX 23 2 Software installation 14 Start copying files Verify the selected features and folders and click Next Scanora 5 0 1 InstallShield Wizard ea Setup is ready to install Scanora to this computer with the following settings Current Settings Features selected Database Client Dicom components Installed devices Destination folder C Program Files x86 Scanora Database media folder C ScanoraData Database tables folder C Program Files x86 Scanora D atabase S tu A Install Siield 15 If NET 2 0 is missing Installing NET 2 0 Wait for 1 10 min
89. te ttes 110 10 3 Interface to access image information 111 11 Software eni le tes aeter OR tradet enna eset es 113 207633 rev 2 SOREDEX iii SOREDEX 207633 rev 2 1 Introduction 1 Introduction 207633 rev 2 1 1 General SCANORA software hereafter called the software is a complete solution for digital image acguisition processing viewing and storing The software supports SOREDEX SCANORA 3D CRANEX D CRANEX 3D CRANEX Novus DIGORA PCT DIGORA Toto and DIGORA Optime devices DIGORA Vidi and other intraoral cameras Images can also be imported from other digital sources The software stores images and patient information in a SQL database and provides tools for image archiving This installation manual covers the installation of the software Standard and DICOM versions The user manual describes how to use the software See the eguipment manuals before installing or using the eguipment See the Windows manuals for further information about the Windows environment With the software you can perform the following operations assuming that all the eguipment is ready for use Create a new patient and store patient information in a database Capture and store digital X ray images with exposure values from the device Capture and store intraoral photographs Export and import digital images Process images to enhance their diagnostic
90. terday s logs are shown and so on To start searching logs click Search The search list can show 500 items at a time If more items exist it is necessary to restrict search with filters or by removing log items SOREDEX 103 9 Software Manager rman oz Licenced Features 104 9 5 9 6 License File Server Configuration In a network configuration as a default computer name is used instead of IP address In case of misconfigured DNS server or absence of a local DNS server it is recommended to use the IP address This can be manually done using the file server configuration by specifying the correct IP address instead of the computer name The default port for File Server is 899 In case the defualt port is being used by some other application default port can then be changed using File Server configuration File server configuration is done from File File Server Configuration File Help SCANORA Manager Archive Images Database File Server Configuratio Q Create User management O Restore Database backup Licence Exit Report US SOREDEX NOTE 7he File server IP must not be configured to a different computer than where the Database is running License The currently installed license key is shown in the dialog Click License to change the key Enter license key x of Cancel SOREDEX 207633 rev 2 9 Software Manager Fill in
91. tication select SQL Server and Windows Authentication mode and click OK Then click OK on the dialog stating the need to restart SQL server To restart the server select the server and then right click for Restart If an SQL Server Agent is running it must be restarted also SOREDEX 73 5 Software database 74 1 See chapter 2 Software installation to follow instructions until the Select Features screen is shown Scanora 5 0 1 InstallShield Wizard C Common C Database engine Database sharing 8 0 Client CI Common Image capturing Client touch panel mode EL DICOM L Common Print Worklist C Storage Cl Query Retrieve I SOREDEX 0 00 MB of space required on the C drive Instal lt Back n Net Cancel Select the Database feature and remove the Database engine selection i e only the Common sub feature is selected Click Next Select folder for database media files and click Next Select the database server that you want to install the software database to Available instances are shown in the drop down menu Make sure that the Connect using setting is SQL Server authentication using Login ID and password below Fill in the correct Login ID and Password and click Next Scanora 3 0 InstallShield Wizard local SC amp ANORA Data t you are installing to I SOREDEX Installshield SOREDEX 207633 rev 2 207633 rev 2 5 Software da
92. tion places in the Destination List Select the destination entry to be set as the default Click Default to set this destination as the default Storage page Verify button DICOM Verification All communications and image transfer with the remote application are accomplished using the DICOM protocol over a network using the TCP IP protocol stack Verify application level communication between DICOM application entities AE s click Verify If there are no selected items highlight in the destination list the Edit Delete Set as Default and Verify buttons are disabled Select the destination item to be verified All buttons are enabled Click Verify The DICOM Verification window gives information on the state of communication between the destination and computer If communication is successful a verification window appears showing all the parameters x File Help m DICOM Parameters Application Entity Title Merge_store_scp Host name or IP address 127 0 01 Port Mumber 104 Network Parameters Network status OK Association status Normal Completion Remote Implementation Class UID 2 16 840 1 25 1 Remote Implementation Version MergeCOM3 321 SevieName Ree syntax Service utd syntaxuD STANDARD CR 5 EXPLICIT LITTLE EM 1 2 840 10008 5 1 2 840 10008 STANDARD CT SCP EXPLICIT LITTLE EM 1 2 840 10008 5 1 2 840 100068 STANDARD CURVE SCP EXPLICIT LITTLE EM 1 2 840 100
93. tor password in the command line admin by default 3 The software database file is backed up pidbmsde dat in the backup directory e g ScanoraData Backup 4 Make a backup of the image directory e g C ScanoraData INCLUDE ALL CONTENTS 5 Mark the backup media with the current date and store it in a safe place SOREDEX 19 5 Software database 80 5 3 2 Restoring the software database from the backup NOTE f you use 32 bit SAL Server in 64 bit Windows do a following modification into ImportDB bat before executing it Replace instances of Program Files with Program Files x86 in OSQLEXE and SQLCMD definitions NOTE This procedure overwrites any existing patient data stored in the software database NOTE This procedure does not restore users and creates default users Use the software Manager to recreate users 1 Make sure that all users have been logged off the software database restore does not succeed if the database is in use e g make sure that PaloDEx 3D Reconstruction Service and SCANORA Database Backup Service are not running Restore the image directory e g C ScanoraData from the backup INCLUDE ALL CONTENTS Run ImportDB bat located in the Tools folder In Windows 7 run file in command line opened with Run as administrator Enter the administrator password in the command line admin by default The database along with all the image data is now restored SOREDEX 20
94. tware 88 SOREDEX 207633 rev 2 7 Adding features 207633 rev 2 7 1 It is possible to add features or modalities at any time after the installation e g DICOM Adding devices X ray device support in the software is installed during the software installation You can add a new X ray device at any time after the installation Add devices in the software by selecting Tools Installed devices NOTE ntraCam is in the dialog only when Intra Camera is installed to the PC Only with CRANEX D To use an X ray device install also the sensor specific gain file by using Gain Installer Start Programs SCANORA Tools Gainlnstaller File Help Selected Gain files Browse Install Update Exit Insert the Gain file media and browse the Gain file Select all the gain files and click Install Remember to copy the gain files for each camera and sensor NOTE DIGORA Toto gain files are installed automatically when the DIGORA Toto image capturing is started for the first time If the gain files need to be updated click Update to copy the files to local workstations SOREDEX 89 7 Adding features 90 7 2 Adding options You can add a new option e g DICOM at any time after the installation 1 Start Settings Control Panel Add or Remove Programs Vista Programs and Features Select SCANORA Click Change The software Setup Maintenance program starts Select
95. utes 16 If Database Engine was selected Installing database engine Wait for 1 15 minutes 17 Copying files dialog Wait for 1 5 minutes 18 DirectX license agreement Read the license and click Yes 19 Modality workstation only Gain file installation for CRANEX D The installation wizard asks Do you want to install Gain files Click Yes Gainlnstaller dialog opens Insert the Gain file media and browse the Gain file Select all the gain files and click Install NOTE The DIGORA Toto gain files are installed automatically when the DIGORA Toto image capturing is started for the first time 24 SOREDEX 207633 rev 2 207633 rev 2 2 Software installation 20 InstallShield Wizard Complete Reboot the computer if reboot is asked and click Finish NOTE If You get the following error message during the installation click OK to continue installation The Windows Installer service cannot update the system file c WINDOWS system32 msxml6r dil because the file is protected by Windows You may need to update your operating system for this program to work correcily NOTE Make sure that the screensaver does not lock the computer on the CB3D image capturing workstation 2 2 Display settings for the software The Windows display settings may have to be changed if the display is difficult to read after the software installation To change display mode select Start Settings gt Control Panel and doub
96. value with dental specific tools Analyse the image with application specific measurement tools Build an environment with multiple workstations using a database shared over a network Printing images and image information Capture 3D images and launch 3rd party image analyzing and planning tools The software allows you to import and export image files Supported file formats are D32 JPG JPG2000 TIF BMP and PNG D32 is SOREDEX s proprietary own file format Images can be saved in the database in PNG 16 bit or JPG formats 12 bit SOREDEX 1 1 Introduction 1 2 1 3 The software can be used in a network environment If the software is installed in several computers the patient and image database can be shared and used from different workstations We recommend to read this manual before installing and using the software Manufacturer s liability As a manufacturer we can only assume liability for safe and reliable operation of this software when the PC software is installed and used according to the software installation and user manuals NOTE Safe and reliable usage of the product requires that the user has read and understood the instructions and restrictions given in the manual Abbreviations PC Personal computer HD Hard disk Hz Hertz cycles per second MHz Megahertz millions of cycles per second CPU Central processing unit computer RAM Ra
97. ver and then reinstall it The procedure is as follows 1 Click Control Panel System and select the hardware tab Click the driver and select Uninstall Click OK System Properties System Restore Automatic Updates li Remote General ComputerName Hardware Device Manager The Device Manager lists all the hardware devices installed d on your computer Use the Device Manager to change the properties of any device Drivers E Driver Signing lets vou make sure that installed drivers are compatible with Windows Windows Update lets you set up how Windows connects to Windows Update for drivers Driver Signing Windows Update Hardware Profiles Hardware profiles provide a way for you to set up and store E different hardware configurations Hardware Profiles Advanced Device Manager File Action View Help AMARA S4 PALODEX 2251919 Computer Disk drives 5 9 Display adapters Intel R 82945G Express Chipset Family amp Intel R 82945G Express Chipset Famil DVD CD ROM drives H Floppy disk controllers id Floppy disk drives FE fgg Human Interface Devices H IDE ATA ATAPI controllers jp IEEE 1394 Bus host zontrollers Keyboards Ej Mice utl ier pointing devices Network adapters B 4 Other devices Multimedia Audio Controller 2 SM Bus Controller 1 P PaloDEx Group imagng devices Serial Link PCI Ports COM Update Driver MR Proce
98. y Date and Study Time tags of a new study are filled when the study is created from a worklist item that lacks the Study Date and Study Time values SOREDEX 207633 rev 2 4 Configuring DICOM 4 4 Storage and Storage Commitment configuration The Storage page allows the storage and storage commitment parameters to be defined When this page is opened for the first time after installation two empty lists appear The Storage Destination List upper The Storage Attributes List lower DICOM settings General SOP Classes Worklist Storage Print Query Retrieve Storage SCP Store images automatically when saving Destination AE Title IP Address Port Number PACS PACS AE 127 0 0 1 104 Verify Advanced Add new Delete Tag Name Type Default Value Add new Storage Commitment Use Storage Commitment Cancel Apply The Storage Destination List upper Add storage servers to the storage server destination list e g DICOM ARCHIVES The Storage Attributes Tag List lower Add and edit DICOM Tag information to the tag list 207633 rev 2 SOREDEX 49 4 Configuring DICOM 50 4 4 1 Storage page Destinations Storage page Add new button IP Address Title Merge store scp Verify Set as Default Advanced Add new ERE Delete Allows a new destination for the images