Home

St200-S User Manual

image

Contents

1. Connection 23 No Connection 24 No Connection 25 No Connection 26 No Connection Record tally out Open collector Play tally out Open collector Stop tally out Open collector Rewind tally out Open collector Rewind tally out Open collector Fast Forward tally out Open collector None None Record command Play command Stop command Rewind Command Fast Forward Command Pause None None NOTE There are no internal current limiting resistors for the open collector Tally Outputs Limit each Tally Output current to 40ma 9 ST200 S 7 TOP VIEW REAR VIEW ST200 Top View CONTROLLER UNIVERSAL VTR CONTROLLER LUE 1 PRERULL SETUP STANDBY GOTO 3 4 0 2 o o e eee KF U U A PLAY STOP REWIND FFWD JOG e e Boe ee III a K 6 7 8 8 DEL ESCAPE ST200 Rear View n POWER VTR GPI deo 7 e eT PIN1 5v PIN3 GND RESET 10 ST200 S 8 DNF CONTROLS LIMITED WARRANTY DNF Controls warrants its product to be free from defects in material and workmanship for a period of one 1 year from the date of sale to the original purchaser from DNF Controls In order to enforce the rights under this warranty the customer must first contact DNF s Customer Support Department to afford the opportunity of identifying and fixing the problem without sending the unit in for repair If DNF s Customer Support Department cannot fix the problem the customer
2. will be issued a Returned Merchandise Authorization number RMA The customer will then ship the defective product prepaid to DNF Controls with the RMA number clearly indicated on the customer s shipping document The merchandise is to be shipped to DNF Controls 12843 Foothill Blvd Suite D Sylmar CA 91342 USA Failure to obtain a proper RMA number prior to returning the product may result in the return not being accepted or in a charge for the required repair DNF Controls at its option will repair or replace the defective unit DNF Controls will return the unit prepaid to the customer The method of shipment is at the discretion of DNF Controls principally UPS Ground for shipments within the United States of America Shipments to international customers will be sent via air Should a customer require the product to be returned in a more expeditious manner the return shipment will be billed to their freight account This warranty will be considered null and void if accident misuse abuse improper line voltage fire water lightning or other acts of God damaged the product All repair parts are to be supplied by DNF Controls either directly or through its authorized dealer network Similarly any repair work not performed by either DNF Controls or its authorized dealer may void the warranty After the warranty period has expired DNF Controls offers repair services at prices listed in the DNF Controls Price List DNF Controls res
3. 12843 Foothill Blvd Suite D Sylmar CA 91342 818 898 3380 voice 818 898 3360 fax www dnfcontrols com Model No ST200 S Universal VTR DDR Controller USER MANUAL Manual Version 3 11 102506 Document No ST200 S_User Manual 1 ST200 S Table of Contents REVISION HISTORY DESCRIPTION FEATURES a TIME CODE DISPLAY b ROW OF KEYPAD c BOTTOM ROW OF KEYPAD d NUMERIC KEYPAD INSTALLATION OPERATION a NUMERIC KEYPAD b CUE POINT ENTRY d RECORD MODE SELECTION RECORD SELECTOR SWITCHES f TIME CODE DISPLAY SPECIFICATIONS TOP PANEL REAR PANEL RS422 SERIAL CONNECTOR POWER CONNECTOR GPI CONNECTOR TOP VIEW REAR VIEW DNF CONTROLS LIMITED WARRANTY ST200 S Mo GO GO G o D cd A CA CO A Un d A A G W UU m m 3 REVISION HISTORY 010504 Rev 3 1 Company header information revised Added DNF Controls Limited Warranty 102506 Rev 3 11 Added Timecode select function DESCRIPTION The ST200 UNIVERSAL Controller provides low cost control over a wide range of RS422 VTR and DDR formats and brands in your facility Simple and easy to use No complicated menus to search through All the functions you need at the press of a button Eliminates the need for multiple remote controllers and the associated clutter of several pieces of control hardware Numeric Keypad provides easy entry of Search To locations One ST200
4. UNIVERSAL VTR DDR controller controls them all D1 D2 D3 D5 DCT Betacam MII 1 inch 34 inch S VHS and Hi 8 Sony BTS Panasonic JVC Grass Valley Group Leitch and Drastic Technologies 24 function keypad gives you the functions you need at the press of a button FEATURES Timecode tape time display Jog Shuttle Wheel 12 function keypad provides the functions you need at the press of a button Small footprint desktop unit 8 V2 x 5 12 Can be easily customized for your specific needs Customize the ST200 with the transport control functions and status indicators you require for your specific applications Can be used though your facility s existing RS422 Control router RS422 patchbay or 9 pin switch box a TIME CODE DISPLAY Display timecode or CTL Tape Timer per the mode selector switch on the front panel of the VTR The Time Mode can be selected manually by pressing the SHIFT JOG keys each press will step to the next Time Mode CTL Tape Time Timecode VITC ST200 S b TOP ROW OF KEYPAD Search To Cue 1 CUE1 Search To Cue 2 CUE2 Preroll PREROL Record Setup SETUP Standby On Off STDNBY GOTO To Time GOTO Mark Enter CUEI SHIFT CUE1 Mark Enter CUE2 SHIFT CUE2 BOTTOM ROW OF KEYPAD Record REC Play PLAY Stop STOP Rewind RWD Fast Forward FFWD Jog Shuttle Select JOG NOTE Jog Shuttle Wheel Active ONLY from STOP STILL JOG and SHUTTLE modes d NUMERIC KEYPAD When enterin
5. ble Record ON OFF OFF OFF OFF OFF Crash Record OFF ON OFF OFF OFF OFF Insert Record ON VID AUDI AUD2 AUD3 AUD4 ActiveON Front Panel SETUP OFF OFF OFF OFF OFF ON NOTE AUD3 amp AUD4 should be ON ONLY for VTRs that support 4 channels of audio i e D1 D2 and D3 type VTRs TIME CODE DISPLAY Display timecode or CTL Tape Timer per the mode selector switch on the front panel of the VTR The Time Mode can be selected manually by pressing the SHIFT JOG keys each press will step to the next Time Mode CTL Tape Time Timecode VITC ST200 S 8 SPECIFICATIONS TOP PANEL 12 Status LEDs 3 Direction LEDs Switches Display Jog Shuttle Wheel Size Weight REAR PANEL RS422 Serial Out DIP Switches Display Power GPI Status Output Record Play Stop Rewind FFwd Jog Cue 1 Cue 2 Preroll Setup Standby Goto Indicates direction of Jog Shuttle Record Play Stop Rewind Fast Forward Jog Shift Reset Cue 1 Cue 2 Preroll Setup Standby Goto 2 Line LCD With Mechanical Detents at 1X Play Speed Lx WXH 8 1 2 x 5 1 2 x 1 1 2 Front 2 1 2 Rear 3165 9 pin D type connector female DB9 F RECORD MODE Lockout Crash Insert Assemble Contrast adjustment 5 volt D C 500 ma 90 265 VAC 50 60 Hz converter supplied Rack Mount or Tabletop 15 pin D type connector female DB15F Switch Input SPST contact closure momentary Open collector sink 50mA RS422 SERIAL CONNECTOR 9 P
6. bled on the VTR or tape cassette Loss of serial communication with the VTR is indicated by ALL status LEDs turned ON Selecting LOCAL control on the VTRs from panel will turn OFF all status LEDs a C NUMERIC KEYPAD To turn on the Numeric Keypad press the GOTO key NOTE The transport control functions are inoperative while the Numeric Keypad is turned on The status indicators will turn off and the transport will remain in the last selected mode Press the desired number key to enter a number The entered number will be displayed in the current time location The cursor will move one location to the left with each entry Press DEL to move the cursor one location to the right Press GOTO to search to the entered time location OR press ESCAPE to exit the numeric keypad without searching CUE POINT ENTRY Press SHIFT CUE1 or SHIFT CUE2 to enter a time into the selected Cue Point The cursor is placed at the far right and the Numeric Keypad is turned on NOTE The transport control functions are inoperative while the Numeric Keypad is turned on The status indicators will turn off and the transport will remain in the last selected mode Press the desired number key to enter a number The entered number will be displayed at the cursor The cursor will move one location to the left with each entry Press DEL to move the cursor one location to the right To automatically load the current time into the Cue Point pre
7. erves the right to refuse repair of any unit outside the warranty period that is deemed non repairable DNF Controls shall not be liable for direct indirect incidental consequential or other types of damage resulting from the use of the product 11 ST200 S
8. g GOTO or CUE time the ST200 s keypad now has the following functions Switch Numeric Keypad Function CUEI 0 CUE2 1 PREROL 2 SETUP 3 STNDBY 4 GOTO GOTO Begin Search RECORD 5 PLAY 6 STOP 7 RWD 8 FFWD 9 JOG DELETE Move cursor left one position SHIFT ESCAPE enter mode 4 ST200 S 5 INSTALLATION a Plug one end of a 9 conductor RS422 serial cable in to the 9 pin connector on the rear of the ST200 Plug the other end of the cable into the 9 pin remote connector on the VTR b Plug the 9 pin female connector of the Universal Power Supply into the POWER connector on the rear of the ST200 Plug the free end of the Universal Power Supply into a wall outlet 90 VAC to 240 VAC 10 Select REMOTE mode on VTRs front panel d Set the RECORD SELECTOR SWITCHES located on the rear panel of the ST200 for the desired record mode per the RECORD SELECTOR CHART below NOTE for AMPEX 1 inch and D2 VTRs set VTR ID to 0001 Installation is complete ST200 S 6 OPERATION Select the desired transport function by pressing the appropriate key on the front of the ST200 The Real Time Status Indicators will light to indicate the VTRs current tape transport mode For example Pressing PLAY will put the VTR into the PLAY mode The PLAY Status Indicator will light when the VTR is in PLAY mode Press only RECORD to put the VTR into Record mode NOTE The VTR will not go into Record mode if Record Inhibit is ena
9. in D Type Female DB 9F 6 Receive Common Pin 1 Frame Ground 7 Receive B 2 Receive A 8 Transmit A gt 3 Transmit B gt 9 Frame Ground 4 Transmit Common 5 Spare POWER CONNECTOR 9 Pin D Type Male Pin 1 5V DC 6 Not Used 2 Not Used 7 Not Used 3 Ground 8 Not Used 4 Not Used 9 Not Used 5 Not Used ST200 S GPI CONNECTOR 15 Pin Female DB15F Version 6 Hardware d 2 FUNCTION 5v DC SHIFT Switch Record Tally Play Tally Stop Still Tally Rewind Reverse Tally Fast Forward Forward Tally Jog Tally Command Common Record Command Play Command Stop Command Rewind Command Fast Forward Command Jog Shuttle Select Command WES ste eh NOTE Active Low Active Low Open Collector Active Low Open Collector Active Low Open Collector Active Low Open Collector Active Low Open Collector Active Low Open Collector Active Low Active Low Active Low Active Low Active Low Active Low NOTE There are no internal current limiting resistors for the open collector Tally Outputs Limit each Tally Output current to 40ma 26 Pin D Type Female DB26F Version 7 Hardware ONLY GPI CONNECTOR Pin 1 GPI 1 Out 2 GPI 2 Out 3 GPI 3 Out 4 GPI 4 Out 5 GPI 5 Out 6 GPI 6 Out 7 GPI 7 Out 8 GPI 8 Out 9 Common Ground 10 GPI 1 In 11 GPI 2 In 12 GPI 3 In 13 GPI 4 In 14 GPI 5 In 15 GPI 6 In 16 GPI 7 In 17 GPI 8 In 18 Common Ground 19 5 VDC 20 5 VDC 21 No Connection 22 No
10. ss the GOTO key When finished press ESCAPE to turn off the Numeric Keypad SEARCH TO CUE POINT Press CUEI or CUE2 to search to the saved time location ST200 S 7 RECORD SELECTION Four 4 Record modes are available Crash Record Full Record Assemble Record Insert Record and Record Lockout The ST200 offers 2 methods of selecting the desired RECORD MODE Rear Panel DIP switches or Front Panel SETUP 1 METHOD 1 Rear Panel DIP Switches This method allows selection of the RECORD MODE using the Rear Panel DIP Switches Set the DIP Switches per the following Record Selector Switches table Any attempts to change the RECORD MODE from the Front Panel SETUP function will be inhibited 2 METHOD 2 Front Panel SETUP Set the Rear Panel DIP Switches per the Record Selector Switches Table to enable the Front Panel Record SETUP function Press the SETUP key on the front panel The current record mode will be displayed Press the RECORD key to select Record Lockout Assemble Crash or Insert Record modes For Insert selection Press Number Key 0 for Video 1 for Audio 1 2 for Audio 2 3 for Audio 3 4 for Audio 4 Press ESCAPE to save the currently displayed Record mode and exit the SETUP function Upon exiting SETUP the VTR will be configured for the selected Record Mode RECORD SELECTOR SWITCHES Mode S1 S2 S3 S4 S5 S6 Record Lockout OFF OFF OFF OFF OFF OFF Assem

Download Pdf Manuals

image

Related Search

Related Contents

scopa elettrica ricaricabile • electric broom - use instructions  PC対応TDRケーブル診断・測長機 TX6000 PDF  Arat 1257.1 holder  Jenn-Air DW711 Dishwasher User Manual  Gigaset A510/A510A  Texas Instruments MSOP8 User's Manual  Dossier de presse Elections MSA 2010  Tipos de Operaciones - sistema de información  REGLAS GENERALES DE SEGURIDAD  FC60 Disk Array Service Manual  

Copyright © All rights reserved.
Failed to retrieve file