Zipabox Security Module User Manual v1.2
Contents
1. 5 1 1 NORMALLY CLOSED ZONE For this zone configuration to be active in the Zipabox interface go to Device Manager select Security module and appropriate zone and select Normally closed zone from the Zone Wiring drop down Normally closed zone is the most basic wiring type In this configuration connect one or more normally closed NC contacts in a wiring loop Each contact may be a sensor or a tamper contact User interface for this zone will display INACTIVE status when the loop is closed and ACTIVE status when the loop is open Upon zone state change both sensor and tamper events will be generated tamper events are visible in the Alarm panel make your home smart NORMALLY CLOSED LOOP Zone Zone terminal COMMON terminal COMMON One or more normally closed contacts with no end of line resistor 5 1 2 END OF LINE RESISTORS In normally closed zone configuration wired loop with normally closed contacts 01 Security module views short circuit as normal condition and an open circuit as a fault or alarm condition 02 If the wired loop is shorted by accident or malice that state is indistinguishable from normal condition The purpose of end of line resistors EOLR s is to allow Security module to differentiate between an active alarm tampering with sensor wiring and a short in a wire EOLR s have to be installed at the last device on the loop and not at the Security module terminals
2. zipato everything under control L ZIPABOX SECURITY EXPANSION MODULE QUICK a rr GUIDE V1 TRADEMARKS Zipato and the Zipato logo are registered Trademarks All other product names mentioned herein may be trademarks or registered trademarks of their respective companies NOTICE Although Zipato has attempted to ensure the accuracy of the content of this manual it is possible that this document may contain technical inaccuracies typographical or other errors Zipato assumes no liability for any error in this publication and for damages whether direct indirect incidental and consequential or otherwise that may result from such error including but not limited to loss of data or profits Zipato provides this publication as is without warranty of any kind either express or implied including but not limited to implied warranties of merchantability or fitness for a particular purpose The published information in the manual is subject to change without notice Zipato reserves the right to make changes in the product design layout and driver revisions without notification to its users This version of the Installation guide supersedes all previous versions ELECTROMAGNETIC COMPATIBILITY In proper state and when operated properly the product complies with all the requirements in respect of interference radiation according to EN 301 489 17 EN 301 489 1 and EN 300 328 The connections conducting HF s
3. INPUT IN IN Connect a device that provides voltage output of 8 14 Voc with positive wire going to terminal marked IN and negative wire going to IN This input will consume no more than 40mA of current and has an internal 1kQ termination resistor so this input can be used to interface Security module with existing alarm panel siren output 5 3 SUPERVISED BELL SIREN OUTPUT Bell output will supply 600mA of current at 12Vpc The output is supervised and power limited If unused connect a 1kO termination resistor to across BELL and BELL terminals to prevent tamper event generation Bell output is protected from over current by an electronic fuse 5 4 AUX POWER OUTPUT For powering wired sensors that require 12Vpc connect respective wires to the AUX and AUX power terminals Output is monitored for short circuit and current limited All devices connected to these terminals should not draw more than 800mA of current While operating on battery voltage output will vary between 10 and 14 Voe AUX and BELL terminals share the same protection device so an over current or short circuit condition on AUX terminals will also render BELL output inoperable two tamper events will be generated 5 5 PROGRAMMABLE PGM OUTPUT PGM output is a single pole normally open solid state relay output Maximum current is 150mA for larger currents an external relay is required Maximum allowed voltage is 24Vpc Vrms Maximum on state resistance i
4. WARRANTY This warranty applies only to defects in parts and workmanship relating to normal use It does not cover damage incurred in shipping or handling damage caused by disaster such as fire flood wind earthquake or lightning damage due to causes beyond the control of Tri plus grupa such as excessive voltage mechanical shock or water damage damage caused by unauthorized attachment alterations modifications or foreign objects damage caused by peripherals unless such peripherals were supplied by Tri plus grupa Ltd defects caused by failure to provide a suitable installation environment for the products damage caused by use of the products for purposes other than those for which it was designed damage from improper maintenance damage arising out of any other abuse mishandling or improper application of the products 9 4 ITEMS NOT COVERED BY WARRANTY In addition to the items which void the Warranty the following items shall not be covered by Warranty freight cost to the repair centre products which are not identified with TRI PLUS GRUPA s product label and lot number or serial number products disassembled or repaired in such a manner as to adversely affect performance or prevent adequate inspection or testing to verify any warranty claim Access cards or tags returned for replacement under warranty will be credited or replaced at TRI PLUS GRUPA s option Products not covered by this warranty or otherwise out of wa
5. a sensing device evade detection by moving through an area of insufficient coverage disconnect a warning device or interfere with or prevent the proper operation of the system 6 5 POWER FAILURE Control units intrusion detectors smoke detectors and many other security devices require an adequate power supply for proper operation If a device operates from batteries it is possible for the batteries to fail Even if the batteries have not failed they must be charged in good condition and installed correctly If a device operates only by AC power any interruption however brief will render that device inoperative while it does not have power Power interruptions of any length are often accompanied by voltage fluctuations which may damage electronic equipment such as a security system After a power interruption has occurred immediately conduct a complete system test to ensure that the system operates as intended make your home smart 6 6 FAILURE OF REPLACEABLE BATTERIES For wireless sensors the expected battery life is a function of the device environment usage and type Ambient conditions such as high humidity high or low temperatures or large temperature fluctuations may reduce the expected battery life While each transmitting device has a low battery monitor which identifies when the batteries need to be replaced this monitor may fail to operate as expected Regular testing and maintenance will keep the system in good operating
6. condition 6 7 COMPROMISE OF RADIO FREQUENCY WIRELESS DEVICES Signals may not reach the receiver under all circumstances which could include metal objects placed on or near the radio path or deliberate jamming or other inadvertent radio signal interference 6 8 SYSTEM USERS A user may not be able to operate a panic or emergency switch possibly due to permanent or temporary physical disability inability to reach the device in time or unfamiliarity with the correct operation It is important that all system users be trained in the correct operation of the alarm system and that they know how to respond when the system indicates an alarm 6 9 SMOKE DETECTORS Smoke detectors that are a part of this system may not properly alert occupants of a fire for a number of reasons some of which follow The smoke detectors may have been improperly installed or positioned Smoke may not be able to reach the smoke detectors such as when the fire is in a chimney walls or roofs or on the other side of closed doors Smoke detectors may not detect smoke from fires on another level of the residence or building Every fire is different in the amount of smoke produced and the rate of burning Smoke detectors cannot sense all types of fires equally well Smoke detectors may not provide timely warning of fires caused by carelessness or safety hazards such as smoking in bed violent explosions escaping gas improper storage of flammable materials overloa
7. for the remainder of the original warranty or ninety 90 days whichever is longer The original purchaser must promptly notify Tri plus grupa in writing that there is defect in material or workmanship such written notice to be received in all events prior to expiration of the warranty period There is absolutely no warranty on software and all software products are sold as a user license under the terms of the software license agreement included with the product The Customer assumes all responsibility for the proper selection installation operation and maintenance of any products purchased from TRI PLUS GRUPA Custom products are only warranted to the extent that they do not function upon delivery In such cases TRI PLUS GRUPA can replace or credit at its option 9 1 INTERNATIONAL WARRANTY make your home smart The warranty for international customers is the same as for any customer within Canada and the United States with the exception that Tri plus grupa shall not be responsible for any customs fees taxes or VAT that may be due 9 2 WARRANTY PROCEDURE To obtain service under this warranty please return the item s in question to the point of purchase All authorized distributors and dealers have a warranty program Anyone returning goods to Tri plus grupa must first obtain an authorization number Tri plus grupa will not accept any shipment whatsoever for which prior authorization has not been obtained 9 3 CONDITIONS TO VOID
8. other devices connected to other Zipabox modules Minimum make your home smart recommended battery capacity is 4Ah and if no powered sensors or USB devices are connected to Zipabox this battery will provide 12 hour standby Battery capacity will deteriorate with age and number of charge discharge cycles so it s recommended to replace the battery every 3 5 years Battery terminals are protected against reverse polarity with a diode crowbar circuit and reversing the battery polarity will DESTROY the fuse In order to restore battery functionality fuse will need to be replaced Procedure to replace the fuse 1 obtain a good quality mini blade automotive fuse rated for 3A or 5A such as Littelfuse 0297003 WXNV 2 remove any wires connected to Z IN BAT AUX BELL PGM or COM terminals 3 remove any modules connected to Security module including Zipabox 4 locate two screws on the underside of the Security module and unscrew them 5 while holding the underside of the security module in one hand press lightly on the longer side of the module topside and carefully slide the topside of the module off 6 remove the PCB assembly from plastic casing 7 holding the lower PCB carefully pull the upper PCB upwards 8 locate the fuse on the underside of the PCB remove the old fuse from the holder and replace it with a new one see Figure 2 9 reverse actions from steps 7 to step 1 Fuse inserted into fuse holder Figure 2 Underside
9. ATURE RANGE 0 50 C HUMIDITY RANGE 0 95 RH POWER powered by Zipabox AUX POWER 10 14 Voc 800mA BELL SIREN OUT 10 14 Voce 600 mA SIREN IN 8 14Vpc 20mMA max PGM OUT 150mA max solid state relay with selectable active level see 3 5 5 0 INSTALLATION NOTES 01 Power off you Zipabox 02 Connect security module to the left side slot 1 of the Zipabox if using Zipato Power or Backup module Security module connects after those modules as shown int he picture bellow QIIISSSS www zipato com 01 1 Align connector of to expansion Slot 1 of Zipabox or to module connected into Slot 1 2 Join module and Zipabox together until gap between them is completely closed 03 Connect your wired sensors to Zone1 6 04 Connect output from your existing panel or some external sensor to terminals marked IN IN 05 Connect your wired bell siren to terminals marked BELL BELL 06 If using any powered sensors connect them to AUX AUX terminals 07 Connect a relay or other low power 12V device to the PGM output 08 Connect a lead acid 12 V battery to terminals marked BAT BAT Warning Failing to observe correct polarity while connecting battery will result in a shorted fuse 09 If applicable connect a supported USB device to the USB port 10 If applicable connect a supported device to the serial port 11 Restore power to your Zipab
10. Placing resistors anywhere other than at the sensor contact does NOTHING to supervise the wiring which is the purpose for using resistors With NC contact EOLR s are optional When put in they detect whether the wiring was shorted NORMALLY OPEN Normal Tampered Zone Zone terminal COMMON terminal COMMON NO contacts should always use EOLR s Without resistors there is no way to differentiate between a fault broken wire and a normal condition 5 1 3 SINGLE END OF LINE SEOL RESISTOR For this zone configuration to be active in the Zipabox interface go to Device Manager select Security module and appropriate zone and select Single end of line resistor zone from the Zone Wiring drop down A single resistor is placed in series with NC contact or in parallel with a NO contact Normally closed contact Normally open contact with end of line resistor with end of line resistor Zone Zone terminal COMMON terminal COMMON www zipato com In this zone configuration Security module treats NC contact as a tamper contact and NO contact as a sensor contact and sends events correspondingly As in the closed loop configuration multiple contacts can we wired to a single zone while observing the rule NC contacts in series NO in parallel SINGLE END OF LINE RESISTOR Zone Zone terminal COMMON terminal COMMON One or more normally closed contacts and one or more normally opened contacts with e
11. This warranty contains the entire warranty and shall be in lieu of any www zipato com and all other warranties whether expressed or implied including all implied warranties of merchantability or fitness for a particular purpose and of all other obligations or liabilities on the part of Tri plus grupa Tri plus grupa neither assumes responsibility for nor authorizes any other person purporting to act on its behalf to modify or to change this warranty nor to assume for it any other warranty or liability concerning this product This disclaimer of warranties and limited warranty are governed by the laws of Croatia WARNING Tri plus grupa recommends that the entire system be completely tested on a regular basis However despite frequent testing and due to but not limited to criminal tampering or electrical disruption it is possible for this product to fail to perform as expected 9 6 OUT OF WARRANTY REPAIRS Tri plus grupa will at its option repair or replace out of warranty products which are returned to its factory according to the following conditions Anyone returning goods to Tri plus grupa must first obtain an authorization number Tri plus grupa will not accept any shipment whatsoever for which prior authorization has not been obtained Products which Tri plus grupa determines to be repairable will be repaired and returned A set fee which Tri plus grupa has predetermined and which may be revised from time to time will be charg
12. Top view 1388 8seee Sees SS Kam aes Left side view COMPATIBILITY This Expansion Module is designed to work only with Zipabox HANDLING Do not drop knock or shake the module Rough handling can break internal circuit boards and connectors ENVIRONMENT Do not expose the module to excessive heat or cold as it can damage or shorten the life of electronic circuit boards UNPACKING Zipabox Security Expansion Module consists of 1x Security Module 12x resistors of 5 6kQ value see section 3 1 Zone Wiring Z1 Z6 2x resistors of 1kQ value see section 3 3 Supervised Bell Siren Output If possible dispose this module at a recycling center Do not dispose of this module with the household waste www zipato com 2 0 WIRED ALARM BASICS TYPES OF CONTACTS NO NC NC NO l l c Cc C SPST NO SPST NC SPDT B M Where C is the Common terminal NO is Normally Open contact NC is Normally Closed contact Different symbols for NO and NC contacts Tt Different symbols for resistors IEC IERE SIMPLE WIRED ALARM The most basic wired alarm system is a closed circuit system Alarm Door Window Sensor Copper Wires O Door to outside Glass Break Sensor In this basic security system all switches have normally closed NC contacts All switches are in a wiring loop When the doors and windo
13. ded electrical circuits children playing with matches or arson Even if the smoke detector operates as intended there may be circumstances when there is insufficient warning to allow all occupants to escape in time to avoid injury or death 6 10 MOTION DETECTORS Motion detectors can only detect motion within the designated areas as shown in their respective installation instructions They cannot discriminate between intruders and intended occupants Motion detectors do not provide volumetric area protection They have multiple beams of detection and motion can only be detected in unobstructed areas covered by these beams They cannot detect motion which occurs behind walls ceilings floor closed doors glass partitions glass doors or windows Any type of tampering whether intentional or unintentional such as masking painting or spraying of any material on the lenses mirrors windows or any other part of the detection system will impair its proper operation Passive infrared motion detectors operate by sensing changes in temperature However their effectiveness can be reduced when the ambient temperature rises near or above body temperature or if there are intentional or unintentional sources of heat in or near the detection area Some of these heat sources could be heaters radiators stoves barbecues fireplaces sunlight steam vents lighting and so on 6 11 WARNING DEVICES Warning devices such as sirens bells horns or strobes may n
14. ding to local laws and regulations needs to be disposed of separately from household waste and sent to recycling because it contains electronic components Once this product has reached the end of its life please take it to a collection point recycle facilites designated by your local authorities some will accept your product for free or simply drop it off at your Zipato re seller store By recycling the product and its packaging in this manner you help to conserve the environment and protect human health At Zipato we understand and are committed to reducing any impact our operations and products may have on the environment To minimize this impact Zipato designs and builds its products to be as environmentally friendly as possible by using recyclable low toxic materials in both products and packaging COPYRIGHT 2015 Tri plus grupa d o o All Rights Reserved No part of this manual may be reproduced or transmitted in any form without the expressed written permission of Tri plus grupa d o o www zipato com 04
15. ed for each unit repaired Products which Tri plus grupa determines not to be repairable will be replaced by the nearest equivalent product available at that time The current market price of the replacement product will be charged for each replacement unit 9 0 DECLARATION OF CONFORMITY The Manufacturer Tri plus grupa d o o hereby declares that the product Zipabox Security Module CE In accordance with the following Directivels 2006 95 EC The Low Voltage Directive 89 336 EEC The Electromagnetic Compatibility Directive and 1999 5 EC R amp TT EC Directive is in conformity with the e applicable requirements of the following documents EN 61326 EN 61000 3 3 EN 61000 4 4 EN 61000 4 11 IEC EN 55011 EN 61000 6 2 EN 61000 4 5 EN 301 489 1 3 EN 300 220 2 EN 61000 4 2 EN 61000 4 6 AS NZS IEC 60335 2 97 EN 61000 3 2 EN 61000 4 3 EN 61000 4 8 EN 60335 1 hereby declare that the equipment named above has been designed to comply with the relevant sections of the above referenced specifications The unit complies with all applicable Essential Requirements of the Directives Person responsible for this declaration Sebastian Popovic CEO 07 09 2015 Changes or modifications not expressly approved Tri plus grupa d o o for compliance could void the user s authority to operate the equipment re THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES Operation is subject to the following two conditions 1 this device may not cause harm
16. ful interference and 2 this device must accept any interference received including interference that may cause undesired operation make your home smart NOTE Changes or modifications not expressly approved by Zipato for compliance could void the user s authority to operate the equipment This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help DISPOSING AND RECYCLING YOUR PRODUCT A ESS This symbol on the product or packaging means that accor
17. ignals must neither be manipulated nor damaged TAKE CARE OF YOUR SAFETY Display extreme caution when using ladders or steps please follow manufacturer s instructions Be careful when using hand and power tools and follow the manufacturer s guidelines when using them Take care that the correct tools are used Wear goggles or protective clothing where required DANGER RISK OF ELECTROCUTION All work on the device should only be carried out by trained and skilled electricians Observe the country specific regulations CAUTION The connected devices and the flush mounted receiver can become damaged if devices are operated that do not correspond to the technical specifications see technical data DANGER RISK OF FATAL INJURY FROM ELECTRIC CURRENT The device has no basic insulation and must therefore be installed in a way that protects against accidental contact DANGER RISK OF FATAL INJURY FROM ELECTRIC CURRENT When installing a wall plate the distance between the cover s fixing brackets or screws and the connections of the flush mounted MM Switch Single must be at least 4 mm once installed If the distance is less than 4 mm a deeper installation box must be used The fixing brackets or screws of the cover must not press against the housing Only insulated tools may be used for operation on the device e g an insulated phase tester make your home smart 1 0 INTRODUCTION CONNECTION POINTS
18. nd of line resistor 5 1 4 DOUBLE END OF LINE DEOL RESISTORS For this zone configuration to be active in the Zipabox interface go to Device Manager select Security module and appropriate zone and select Double end of line resistor zone from the Zone Wiring drop down This zone configuration is used with NC contacts and allows Security module to further differentiate between open activated contact and tampered cut loop At the sensor side one resistor is placed in series with NC sensor contact while one resistor is placed in parallel with the contact Zone terminal COMMON Normally closed contact with double end of line resistor In this configuration more NC tamper contacts can be wired in series with the first one DOUBLE END OF LINE RESISTOR Zone terminal COMMON Tamper contact Alarm contact Tamper contact One normally closed ALARM contact and one or more normally closed tamper contacts with double end of line resistor make your home smart 5 1 5 EXAMPLES OF SENSOR WIRING Single NC door window sensor Sensor Zones Zone COMMON A f f f i Single NO door window sensor with single EOLR Sensor Zones Zone COMMON 98 if f Single NO door window sensor with double EOLR Sensor Zones Zone COMMON Multiple NO sensors in parallel with single EOLR Sensor Zones Zone COMMON www zipato com 02 5 2 OPTICALLY ISOLATED
19. of the top PCB 5 7 SERIAL PORT Security module features an UART port which can be configured to be either RS 232 or RS 485 RS 232 mode is supported in 3 wire mode no hardware flow control RS 485 is supported in a two wire half duplex mode Bus biasing 6800 and termination 1200 is built in If using port in RS 232 mode connect your equipment to ports marked RS 232 TX RS 232 RX and GND If using port in RS 485 mode connect your equipment to terminals marked RS 485 A RS 485 B and GND if applicable Use only 26 20AWG 1 5mm wire and strip 9 11 mm of insulation prior to inserting wire To insert wire gently push orange tab insert stripped wire end and then release tab To select active mode of the serial port login to my zipato com and click on General Device Manger locate Security module and configure it On the left pane select tab Configuration Select appropriate mode for the serial port click Save and close the Devices window Click Synchronize to transfer the settings to your Zipabox BEFORE UPGRADING ZIPABOX FIRMWARE DISCONNECT OR POWER DOWN ANY EQUIPMENT CONNECTED TO THE SERIAL PORT 6 0 NOTE TO INSTALLERS This warning contains vital information As the only individual in contact with system users it is your responsibility to bring each item in this warning to the attention of the users of this system 6 1 SYSTEM FAILURES This system has been carefully designed to be a
20. ot warn people or waken someone sleeping if there is an intervening wall or door If warning devices are located on a different level of the residence or premise then it is less likely that the occupants will be alerted or awakened Audible warning devices may be interfered with by other noise sources such as stereos radios televisions air conditioners or other appliances or passing traffic Audible warning devices however loud may not be heard by a hearing impaired person www zipato com 03 6 12 TELEPHONE LINES If telephone lines are used to transmit alarms they may be out of service or busy for certain periods of time Also an intruder may cut the telephone line or defeat its operation by more sophisticated means which may be difficult to detect 6 13 INSUFFICIENT TIME There may be circumstances when the system will operate as intended yet the occupants will not be protected from the emergency due to their inability to respond to the warnings in a timely manner If the system is monitored the response may not occur in time to protect the occupants or their belongings 6 14 COMPONENT FAILURE Although every effort has been made to make this system as reliable as possible the system may fail to function as intended due to the failure of acomponent 6 15 INADEQUATE TESTING Most problems that would prevent an alarm system from operating as intended can be found by regular testing and maintenance The complete system should be
21. ox When the top button on the Zipabox turns solid green your module is ready for configuration and use 12 Login to my zipato com and click on General Device Manager and locate Security module 13 Unhide all zones you wish to use zones are hidden by default On the configuration page for each zone select wiring type PLEASE MAKE SURE THE WIRING TYPE SELECTED ON THE CONFIGURATION PAGE CORRESPONDS TO ACTUAL ZONE WIRING OTHERWISE WRONG EVENTS WILL BE REPORTED 14 After saving changes press Synchronize button to transfer them to your Zipabox 15 Configure your alarm widget and automation rules with the newly added functionality INSTALLATION MOUNTING Meant for mounting only with Zipabox INSTALLING AND CONFIGURING 3G BACKUP OPTIONAL 1 Connect 3G stick to USB port of the Security module 2 Go to Zipato Control Center 3 Click on General settings on the left sidebar 4 Click on Zipabox settings 5 Fill in 3G Backup fields see picture below 6 Save everything 7 Synchronize changes by pressing the Synchronize button on the left sidebar 3G BACKUP SIM APN SIM Pin es SIM Username SIM Password 5 1 ZONE WIRING Z1 Z6 Zones can be wired as normally closed loops with single SEOL or double end of line DEOL resistors Please use wiring appropriate for your sensor contact s Make sure not to exceed 400m maximum wire length per zone Resistor value is 5 6kQ
22. rranty due to age misuse or damage shall be evaluated and a repair estimate shall be provided No repair work will be performed until a valid purchase order is received from the Customer and a Return Merchandise Authorization number RMA is issued by TRI PLUS GRUPA s Customer Service Tri plus grupa Ltd s liability for failure to repair the product under this warranty after a reasonable number of attempts will be limited to a replacement of the product as the exclusive remedy for breach of warranty Under no circumstances shall Tri plus grupa be liable for any special incidental or consequential damages based upon breach of warranty breach of contract negligence strict liability or any other legal theory Such damages include but are not limited to loss of profits loss of the product or any associated equipment cost of capital cost of substitute or replacement equipment facilities or services down time purchaser s time the claims of third parties including customers and injury to property The laws of some jurisdictions limit or do not allow the disclaimer of consequential damages If the laws of such a jurisdiction apply to any claim by or against TRI PLUS GRUPA the limitations and disclaimers contained here shall be to the greatest extent permitted by law Some states do not allow the exclusion or limitation of incidental or consequential damages so that the above may not apply to you 9 5 DISCLAIMER OF WARRANTIES
23. s 80 PGM output default setting is switching to GND when activated It can be also configured to switch to AUX voltage level by changing the built in jumper position To change the jumper position follow this procedure 1 power off your Zipabox 2 remove any wires connected to Z IN BAT AUX BELL PGM or COM terminals 3 remove any modules connected to Security module including Zipabox 4 locate two screws on the underside of the Security module and unscrew them 5 while holding the underside of the security module in one hand press lightly on the longer side of the module topside and carefully slide the topside of the module off 6 locate the jumper cap on the top board of the module and adjust it accordingly see Figure 1 7 slide the top cover back onto the module carefully align both sides of the case and gently press them together to close the gap 8 reverse actions from steps 4 to step 1 Position 2 switches to AUX Position 1 default PGM switches to GND coon Figure 1 Jumper cap positions 5 6 BATTERY To achieve power standby times connect a sealed rechargeable lead acid or gel type battery to terminals marked BAT and BAT Failure to observe correct polarity will result in a burnt fuse Security module charges the battery with maximum of 400 mA float voltage is 13 5 13 8 Voc Standby duration times will depend on battery capacity and number of powered devices connected to AUX terminals and also on
24. s effective as possible There are circumstances however involving fire burglary or other types of emergencies where it may not provide protection Any alarm system of any type may be compromised deliberately or may fail to operate as expected for a variety of reasons Some but not www zipato com Top right angle view Bottom left all of these reasons may be 6 2 INADEQUATE INSTALLATION A security system must be installed properly in order to provide adequate protection Every installation should be evaluated by a security professional to ensure that all access points and areas are covered Locks and latches on windows and doors must be secure and operate as intended Windows doors walls ceilings and other building materials must be of sufficient strength and construction to provide the level of protection expected A reevaluation must be done during and after any construction activity 6 3 CRIMINAL KNOWLEDGE This system contains security features which were known to be effective at the time of manufacture It is possible for persons with criminal intent to develop techniques which reduce the effectiveness of these features It is important that a security system be reviewed periodically to ensure that its features remain effective and that it be updated or replaced if it is found that it does not provide the protection expected 6 4 ACCESS BY INTRUDERS Intruders may enter through an unprotected access point circumvent
25. tested weekly and immediately after a break in an attempted break in a fire a storm an earthquake an accident or any kind of construction activity inside or outside the premises The testing should include all sensing devices keypads consoles alarm indicating devices and any other operational devices that are part of the system 6 16 SECURITY AND INSURANCE Regardless of its capabilities an alarm system is not a substitute for property or life insurance An alarm system also is not a substitute for property owners renters or other occupants to act prudently to prevent or minimize the harmful effects of an emergency situation 7 0 MODELS AND REGIONS ALL COUNTRIES zbm security 8 0 TROUBLESHOOTING Having trouble installing your new product Zipato s website contains the latest user documentation and software updates for Zipato products and services www zipato com You can also find answers in the Zipato Community at community zipato com Zipato Support supportfazipato com 9 0 LIMITED WARRANTY Tri plus grupa warrants the original purchaser that for a period of twelve months from the date of purchase the product shall be free of defects in materials and workmanship under normal use During the warranty period Tri plus grupa shall at its option repair or replace any defective product upon return of the product to its factory at no charge for labour and materials Any replacement and or repaired parts are warranted
26. ws are shut switches attached to them are closed Opening any one of the switches breaks the loop and triggers the alarm circuit The alarm will also activate if the loop is broken if wire is cut alarm will activate WIRED ALARM SYSTEM Modern alarm panels are advanced versions of the basic system outlined above they usually support multiple wired zones lead acid battery backup for power blackouts external siren and advanced user interface graphical display Each wired zone can be used as make your home smart in the simple alarm system outlined above as a closed circuit with all switches wired in a loop Zipabox Security module implements essential features of a wired alarm panel 3 0 FEATURES Zipabox Security Module supports adds wired alarm functionality to Zipabox Security module adds support for 6 wired zones 1 optically isolated 12V input 1 supervised wired bell siren output 1 programmable output 1 supervised 12V auxiliary power supply for powered wired sensors 1 USB port 1 serial UART port user selectable between RS 232 mode and half duplex RS 485 mode 1 lead acit batter charger when using Security Module as a basis for an alarm system the Backup Module can not provide enough voltage to support wired sensors siren and can not be used to power Zipabox and modules in case of a power failure Please use SLA Sealed Lead Acid battery for power backup with Security module 4 0 SPECIFICATIONS TEMPER