Center of Information Technologies NELIAN USER MANUAL

image

Contents

1. 2 On indicator of the 75 output polarization voltage level 3 On indicator of the 100 output polarization voltage level 4 Accessories connection out socket Emitters Accessories connection out socket Emitters Control buttons and indicators are mounted on the remote control see Fig 2 Remote control buttons O BKI NOJIIPA3ANMA 5 1 O 1 25 14 Polarization on button 15 On button of the 25 output polarization voltage 16 On button of the 50 output y a 4 100 aT O ork NOJIAPA3ANHA Pa O BKI MOWY JALMA A O orks MOWY IALMA polarization voltage 17 On button of the 75 output polarization voltage 18 On button for 100 of output polarization voltage 19 Polarization off button 20 Modulation on button 21 Modulation off button Fig 2 Controls and indicators of the DIANEL RPT module remote control Battery replacement for the remote control The remote control uses two AA batteries 1 5 V each IT IS NOT ALLOWED use batteries of other types While putting or replacing batteries it is necessary ah to strictly observe the polarities to use only high quality AA batteries to use identic batteries of the same type and same producer Batteries replacement order 1 put the remote control with its facial down gently slip the battery compartment cover following the direction of
2. 2 4 Module dimensions are 260 mm x 180 mm x 60 mm 2 5 Module weight excluding accessories does not exceed 2 0 kg 2 6 Module life time exceeds 5 years with mean operation usage of 8 hours per day 3 COMPONENTS On the front panel of the module there are controls and indicators as well as the connection slots for the accessories see Fig 1 On the rear panel of the module there are the DIANEL PS special power supply module connection socket and on off switch of the module To use the module for the therapy the corresponding accessories are connected to the module see Fig 3 The module is designed as a device with the DIANEL PS module the special external power supply unit with the output voltage of 12 V For convenience and in order to exclude the galvanic contact with the module and its accessories the device is operated with the remote control see Fig 2 Ham SO a 11 12 13 A ies a PES aes BbICOKOE HANPAKEHME Fig 1 Controls and indication of the DIANEL RPT module Figure 1 shows the controls and indications of the module where serial number production date DIANEL PS special power supply module connection socket slot DIANEL PS RPT power on off switch power on off indicator modulation on off indicator MONYIAUM A IR distance control receiver On indicator of the 25 output polarization voltage level 1 On indicator of the 50 output polarization voltage level
3. 3 Local frankliniZation 0 0cccccccccsessseseseseseseseseeeseseeeseeeseeeseeeeeeeeeseeeeeees 18 5 3 4 Aeroelectrophoresis air ionphoresiS cceeeeeeeeeeeeeeeeeeeeeeeteeeeeeeteeeeees 19 5 3 5 Resonant polarization therapy RPT procedure 20 6 GENERAL INDICATIONS AND CONTRA INDICATIONS cccccccccsesseteeees 22 6 1 Indications and contra indications to resonant polarization therapy are the same as those to franklinization ccccccccccccccececeeeceeceeeeeeeeeeeeeeeeeseseeeeeseeeeeeeees 22 6 2 Indications and contraindications to FRANKLINIZATION air ionization air JOMPNOLESIS E E E E 22 7 MAINTENANCE cccccccccccssssssececececeessesececeeeeccseeaaececeesceceessaeeeeeeseeesssisaeeess 23 Basic Concepts Resonant polarization therapy or therapy of electrostatic field is the continuation of franklinization method Mechanism of action through the tissue fluids there is development of effective polarization of tissues the potential of cell membrane is being restored kind of erythrocyte recharging takes place that leads to the quick resolution of clots and blood bundles reduction of tissue hypoxia and recovery of vegetative nerve ganglion functions Franklinization is a medical treatment practice where the operating factor is high density electrostatic field up to 50 kV as well as the by produced ozone air ions nitrogen dioxide and other products of air ionization There are three fact
4. damaged cells Local franklinization procedures may be conducted along with the As use of pharmaceutical substances aloe extract cevitamic acid solution etc This method is called aeroelectrophoresis Aeroionotherapy air ionization is a treatment method using ionized air Air ions lose their electrical charge once they approach the skin and mucous tunic This charge is given to the tissues blood cells and the air ions become the highly active atoms and molecules Interacting with molecular membrane complexes and interstitial electrolytes the air ions generate different products of electrical exchange and biologically active substances The negative airionotherapy increases the activity of ciliated epithelium of the trachea pulmonary ventilation increases oxygen consumption and carbon dioxide emission stimulates respiratory enzymes and intensifies the tissue oxidation reduction processes Under the influence of the negative air ions there is an increase of haemoglobin and erythrocyte number slow down of erythrocyte sedimentation reaction and blood coagulability change in blood pH into the alkaline side The arterial pressure is reduced under the influence of the negative air ions and the heart rate is slowed down The influence of the negative air ions changes the functional state of CNS increases the reflex excitability of the nerve cells and muscles and strengthens the inhibitory processes in the brain cortex The nega
5. main application resonant polarization therapy RPT additional applications general and local franklinization group or personal air ionization aeroelectrophoresis air ionphoresis The operating factor module induced therapy is the permanent electric field of high intensity up to 30 kV with a small modulation coefficient as well as the products of the air ionization Exposure type electrostatic field In the course of the module induced therapy a person is affected by 6 the electrostatic field of high intensity air ions and chemical agents They cause direct as well as complicated nerve reflective effects Their direct contact with the skin mucous tunic of respiratory tracts leads to the generation of weak direct current within the tissues and production of the active substances in them In turn it causes irritation of skin and mucous tunic receptors In return the capillary vascular network is engaged The local changes of the capillary circulation and thermal regulation contribute to the increase of skin metabolism increase of oxygen consumption stimulation of healing hematogenesis and cell regeneration Mechanism of action through the tissue fluids there is development of effective polarization of tissues the potential of cell membrane is being restored kind of erythrocyte recharging takes place that leads to the quick resolution of clots and blood bundles reduction of tissue hypoxia and recovery of v
6. regard to the indications and contraindications for its use state of the body defences and disease stage 5 1 Safety precautions and restrictions The following are the general recommendations which if followed provide the safety of operation of the device and safekeeping of the module within its extended use and life time There is no need in grounding of the module because the electrical safety is provided by the design features of the module It is necessary to protect the module of dust impacts heat exposure from the near situated hot objects and the open fire Do not disinfect the module case and any accessories if the module is switched on Do not use abrasive materials including grinding powders or chemical agents for example solvents oil etc for the cleaning and disinfection Do not submerge the module into the cleaning fluids even partially In case of staining only cleaning of the module surface is allowed Keep away from moisture In case of moisture ingress do not switch on the module until the complete natural evaporation of moisture Do not use the module in bathrooms shower rooms and in rooms with the high humidity Do not disinfect the electrodes accessories in boiling water If the module or the remote control is taken from the cold place there can be a water film condensate on the electrical components of the module Wait until they warm up to the ambient temperature 5 2 Controls and indicators Con
7. A is placed at the opposite side of the patient s body see Fig 4 o Fig 4 The example of accessories location for DIANEL RPT The exposure is done with the field density voltage of 7 5 15 kV level 1 2 The procedure is usually performed during bandaging in 2 3 days it lasts 10 15 minutes and the whole treatment course includes 10 15 exposures 5 3 4 Aeroelectrophoresis air ionphoresis Before therapy read carefully Sections 5 3 and 5 3 3 Exposure of wounds ulcers and burned surfaces to electrostatic field can be performed along with the use of pharmaceutical substance that is put on a sterile cheesecloth This method is called aeroelectrophoresis air ionphoresis The pharmaceutical substances must have the same charge polarity as that fed to the electrode that is above the pathological nidus The same pharmaceutical substances are used for both electrophoresis and aeroelectrophoresis 19 For the procedure the accessories A and C are used The special electrode C is fixed 5 7 cm off the skin surface above the exposed naked part of patient s body so that a patient will feel smooth blow of the wind The polarizing plate A is placed at the opposite side of the patient s body see Fig 4 The exposure is done with the field density voltage of 7 5 15 kV level 1 2 The procedure is usually performed during bandaging in 1 3 days it lasts 10 15 minutes and the whole treatment cour
8. Before a procedure it is recommended to take away all the metal objects from hair ears pockets because they can cause the deformation of the electric field and the unwanted increase of the exposure in the undesirable places Once a procedure is over the patient must wait 5 10 minutes before he she can stand up The duration dosage and the number of procedures are to be determined by the specialist The methods of procedures are the same as the standard methods of franklinization air ionization aeroelectrophoresis air ionphoresis using the same device Instructions for therapy duration are made as recommendation and depends on the changes that take place during the therapy FOLLOW STRICTLY THE SEQUENCE of actions during a procedure connect corresponding accessories to the 12 and 13 sockets of the module let a patient make himself herself comfortable on a chair couch install and safely fix the corresponding accessories A B C turn the power supply on 4 it is recommended to wait 10 20 second before the next repeated turning on standing at least 1 5 meters from a patient do the following using the remote control turn the polarization voltage on 14 choose the level of the output polarization voltage 15 18 turn the modulation on if necessary 20 after the procedure turn the polarization off 18 turn the modulation off if necessary 21 turn off the module powe
9. Center of Information Technologies NELIAN Resonance Polarization Therapy Module DIANEL RPT Medical diagnostics and therapy system using bioactive points and zones TU 9442 010 14301633 2006 Contents Basic CONCEptS iiinc a aaia aa a Aaa ER eee agi eee 4 1 PRODUCT DESIGNATION 0 0 o oo cccccccececcceceesneseceeeeeeeceeseeseceeeeeeecnessaeseeeeseeenes 6 2 SPEGIFICATIONS ete eee iced eee 8 3 COMPONENT S iijectexsscetcarehachessiddacderahacecsxenceddawaieciivstadeedassdueserveneddaceshadiarsadesedieess 8 3 1 Module aCCeSSOMO S oxen cdtcsecsidc iasan a a iA aA A EA EAA ea 11 4 PREPARATION TO USE tsciseicccsteceds cancecexnne cadsvedncdsas sheesh ceaceaianneranaveeacdeaaebdvedes 12 AS SCONMOCUON a sinzeesvietiecevaidviesvead cetaveadeecevandiedevaandeesvebecudavonnd Gevendvedevabaceeavbbeceeses 12 4 2 On off switching of the module ee ee eee ee eeeeeeeeseeeeeeeseeeeeeeseeeaeeeteeaaeees 13 5 OPERATION xcc ct2ctes edextes sonnia niaan naai AEEA A EA aA EA ANOA AAEE 13 5 1 Safety precautions and restrictions esseeeeeeeeeeseerreseerresterresrerrssrrrrsseee ns 14 5 2 Controls And INGIGAtOMS wise scnscdcesedaceessredandesneccceesteccncessencdersnecetdennancteastecaneass 14 5 3 Operation procedure si ciscccesadscecascancccasnas dinani aiaia aaia iad aa aand ia aai diia 15 5 3 1 General frankliniZation sanninna 17 5S2 All IOMIZAUON cise fn cshececncsccn ten dceciecnredanddencaatennsadanesbacadseunedaneaeedncdensiedaneded 18 5 3
10. along with the high power consumption devices After you finish working with the module unplug the power supply unit from the power line 4 2 On off switching of the module To switch on the module press power on off button 4 on the rear panel of the module Fig 1 Indicator 5 shows the status of the module If the indicators are not on instantly after the module is switched on check whether the power supply unit is connected correctly To switch off the module press power on off button 4 on the rear panel of the module 5 OPERATION Before operation please read carefully the passport and the User manual of the device The strict following all the recommendations stated in the Passport and the User manual is required for the effective operation and safekeeping of the module during its extended use Before the use of the module read carefully the indications and contra indications for its use and if there is such a necessity consult medical specialists The DIANEL system is designated to be used by the qualified specialists and and shall not be used for self healing without the professional consultation indication and supervision Non specialist using the DIANEL complex is liable to any results of its use It is recommended to conduct any kind of therapy with due regard to diagnostics testing results with regular monitoring of the health change dynamics using the diagnostic modules DIANEL BRT or DIANEL BRT OS with due
11. egetative nerve ganglion functions The use of the module elevates the severity of pathological process decreases the size of the lesion zone and contributes to faster patient rehabilitation The module induced therapy has a poly therapeutic action by treating a single disease the comorbid conditions are addressed as well The module DIANEL RPT is designated to be used in research and rehabilitation institutes and centres in emergency centres and teams including mobile ones in places of emergency in epidemiologically hazardous zones in other circumstances requiring the use of the complex or its parts The device can be used outpatiently and in clinic The DIANEL complex is designated to be used by the qualified specialists by doctors trained correspondingly on the subject of electropuncture diagnostics and therapy including the vegetative resonant testing frequency resonant therapy structured resonance therapy bioresonant therapy resonant polarization therapy franklinization air ion therapy and shall not be used for self healing without the professional consultation indication and supervision Non specialist using the DIANEL complex is liable to any results of its use 2 SPECIFICATIONS 2 1 Electrical safety class II BF type O 2 2 The module power supply is done off the module DIANEL PS DIANEL PS RPT the specialized outside power unit with the voltage of 12 V 2 3 Module power consumption does not exceed 20 VA
12. linization A and C accessories are used in local franklinization A and C accessories are used in air ionization A and C accessories are used in aeroelectrophoresis air ionphoresis with pharmaceutical substances local 4 PREPARATION TO USE Before operation please read carefully the passport and this user manual The preparation of the module includes its de preservation preliminary treatment of the case and the working surface of the electrodes and the accessories with 3 solution of hydrogen peroxide with the addition of 0 5 solution of the detergent 4 1 Connection WARNING Connect Accessories only when the module is off Connect the corresponding accessories see Section 3 1 While connecting and the following operation of the module the cables must not be bent twisted or broken without the significant load on the connections The module is powered from DIANEL PS module the special external power supply unit with the output voltage of 12 V The type of the socket must correspond to the plug type of the DIANEL PS module special power supply unit Connect the DIANEL PS module to the main module using the power supply socket 3 see Fig 1 WARNING Use only the genuine DIANEL PS special power unit for the power supply of the main unit 12 The electric socket must be at least 1 5 m away from the patient This is not recommended to connect the module to the power line
13. ors influencing the human organism being franklinized high density electric field air ions and ozone and nitrogen oxides the chemical agents produced in the silent electrical charge Franklinization is the oldest practice of electricity use in medicine There is general and local franklinization General franklinization improves metabolic processes in an organism The defective tonus of the vegetative part of the nervous system is restored Franklinization leads to lower blood coagulability reduced erythrocyte sedimentation reaction and evidence of the bactericidal effect In response to the general franklinization the general organism reactions caused by dermal visceral reflexes appear including improvement of brain blood circulation normalization of excitative and inhibitory processes in cerebral cortex CNS central nervous system reduction of the tonus of the vegetative nervous system and disappearance of sleep disorders There is also evidence of the normalized circulatory dynamics indicators hypertension reduction improvement of respiratory functions reduction of physical and mental lassitude improved performance Local franklinization is the impact of the silent discharge on a small part of a human body It is used for the slow healing contaminated wounds The local franklinization reduces the receptor sensibility has analgetic and antipruritic effects restores the interfacial sensitivity types and stimulates regeneration of
14. r 4 unplug the power supply unit DIANEL PS module take away the corresponding accessories away from the patient While storing the accessories may remain connected to the module IT IS NOT ALLOWED to a patient to stand up during a procedure and touch any grounded metal constructions with any part of the body for example radiators water pipes etc or the body of another person to a specialist it is prohibited to closely approach and touch a patient and or the module and its accessories during the procedure and after it for 5 10 minutes Various types of treatment and therapy may be applied only under the supervision of a doctor to exclude their interference with the obligatorily considered contraindications It is not allowed to treat a person without 16 supervision especially by combining several types of treatment The most complete vision of health state for the more detailed treatment approach is provided by the computer diagnostics by vegetative resonant testing method that allows to determine or specify causes of a disorder The regular repeated diagnostics allows the doctor to reliably follow the progress of treatment and modify the therapy by choosing patient specific types and methods of the therapy that have the maximum efficiency While choosing the specific methods of the therapy it is necessary to consider the functional state of the whole organism and its systems based on the health
15. se includes 10 15 exposures 5 3 5 Resonant polarization therapy RPT procedure Before therapy read carefully Sections 5 3 and 5 3 3 For the local procedures the voltage can be regulated within all the four levels each with the increment of 7 5 kV up to 30 kV To increase exposure efficiency you may turn on the modulation For the procedure the accessories A and B are used It is very important to observe the principle of the correct accessories electrodes location the positive A to the proximal limb part along its rear surface the negative B to the foot hand That is the positive electrode is always positioned higher and the negative electrode is always positioned lower The exposure voltage is regulated based on patients subjective sensations 20 Fig 5 The example of the the polarizing plates location for DIANEL RPT Locate the polarizing plates A and B according to the Fig 5 The exposure is done with the field density voltage ranging from 7 5 kV to 22 5 kV level 1 3 The procedure is usually performed during bandaging in 2 3 days it lasts 10 15 minutes and the whole treatment course includes 10 15 exposures 21 6 GENERAL INDICATIONS AND CONTRA INDICATIONS 6 1 Indications and contra indications to resonant polarization therapy are the same as those to franklinization The patients do not experience any unpleasant feelings during the procedure Some
16. state The type and duration of procedures are to be determined by a specialist The procedures must be conducted under the supervision of a specialist that tests the integrative indicators and if necessary changes the level and duration of exposure in the course of treatment 5 3 1 General franklinization Before therapy read carefully Section 5 3 For the general franklinization both accessories A and C are used For franklinization patient with his her clothes on is seated on a wooden chair The special electrode C is placed 10 15 cm above the head of a patient and the polarizing plate is placed on the floor under the patient s hips The Field density voltage is set within the range of 22 5 30 kV level 3 4 Procedure duration is about 10 15 minutes Procedures are conducted or once in two days or daily The treatment course consists of 10 15 procedures During a procedure patients feel a pleasant fresh wind over the head which is caused by air ion movement aps 5 3 2 Air ionization Before therapy read carefully Section 5 3 For the air ionization the accessory C is used For individually conducted air ionization the special electrode C is placed 10 20 cm aside the patient For air ionization in group the special electrode C is installed in room where the procedure takes place A patient must be 1 meter away from the electrode The Field density voltage is set within the range of 30 kV le
17. the arrow 2 take out the used batteries without touching the plate contacts 10 3 observing polarity install new batteries 4 carefully control the position of batteries in the corresponding compartment there shall be provided the appropriate plus contact of the batteries with contact plates If the batteries are tightly put in the battery compartment the contact may be faulty 5 close slide back the cover of battery compartment It is necessary to change batteries on time depending on their quality and use intensity If there are pauses in use more than 3 days it is necessary to take out the batteries from the battery compartment to avoid remote control damage due to the leakage of electrolyte IT IS PROHIBITED to store the used discharged batteries is in battery compartment of the remote control 3 1 Module accessories A B C Fig 3 DIANEL RPT module accessories A polarizing plate insulated electrode The positive polarizing plate is connected to the out socket 12 of the module B polarizing plate insulated electrode The negative polarizing place is connected to the out socket 13 of the module C specialized needle type electrode non insulated electrode It is is connected to the out socket 13 of the module ll A and B accessories are used in resonant polarization therapy A and C accessories are used in general frank
18. times there is slight pricking or vibration the feeling of mild pushes across the exposed area 6 2 Indications and contraindications to FRANKLINIZATION air ionization air ionphoresis General indications CNS functional disorders initial stage of cerebral vessels atherosclerosis physical and mental strain sleep disorders migraine hypertension I II stage bronchial asthma trophic ulcers persistent wounds burnt surfaces and burn wounds itching paresthesia hyperesthesia The local franklinization is indicated for a patient with itching slowly healing wounds and neurological pains burns paresthesia hyperesthesia ee ee General contraindications malignant neoplasms systemic blood disorders CNS organic disease severe atherosclerosis of coronary and cerebral vessels pregnancy depressions conditions after myocardial infarction acute cerebrovascular disorders acute pneumonia severe pulmonary emphysema bronchial asthma with continuous and severe attacks acute rheumatoid arthritis active progressive pulmonary tuberculosis quick evolving cachexia severe destructive ozena heart failure II and III stage hypersensitivity to ionized air individual intolerance age restrictions Hypersensitivity to electric current cam be referred to the relative contraindications Side effects By disease recrudescence it is required to stop therap
19. tive aeroionotherapy improves the general state normalizers the sleep increases mental and physical performance Negative aeroionotherapy results in improved resistance to various environmental impacts The positive air ions generally cause the opposite changes in the body 1 PRODUCT DESIGNATION The DIANEL RPT module hereinafter referred to as the module is used to conduct resonant polarization therapy The module DIANEL RPT is an updated analogue of the AF 3 1 device for franklinization and air ionization The DIANEL RPT module is a part of Medical diagnostics and therapy complex using bioactive points and zones DIANEL hereinafter referred to as DIANEL complex TS 9442 010 14301633 2006 The DIANEL complex consists of separate stand alone modules and or its modifications which are used for multimodality diagnostics and therapy diagnostic modules of the DIANEL complex DIANEL VRT is a module for the vegetative resonant testing DIANEL VRT OS is a module for the vegetative resonant testing with the advanced functionality therapeutic modules of the DIANEL complex DIANEL FRT is a module for frequency resonant therapy DIANEL BRT is a module for bioresonant therapy DIANEL RPT is a module for resonant polarization therapy DIANEL BN is a module for bionormalization combined therapy DIANEL PS is a power supply unit The module can be used for the following types of therapy
20. trols and indicators are located on the front panel of the module see Fig 1 and on the remote control see Fig 2 The indicator light 5 on the front panel of the module shows that the module is switched on The button of the remote control BKJI HOJIAPH3AUMA 14 enables high voltage polarization voltage and the button 19 disables polarization voltage The buttons of the remote control 15 18 contain 4 levels of the polarization voltage with the increment of 25 or 7 5 kV If a certain level is activated the corresponding indicator on the front panel of the module will be on 14 The remote control turns on off and regulates 4 levels of the output voltage level 1 corresponds to 25 of the output polarization voltage up to 7 5 kV level 2 corresponds to 50 of the output polarization voltage up to 15 kV level 3 corresponds to 75 of the output polarization voltage up to 22 5 kV level 4 corresponds to 100 of the output polarization voltage up to 30 kV The buttons of the remote control BKJI MOAYJIAUMA 20 and OTKJ MOJYIAWUA 21 enable BKI MOA YWLAWMA and disable OTKJI MOJTYJLANUA the modulation of the polarization voltage If the modulation is enabled the indicator light 6 of the module is on if modulation is disabled the indicator is off 5 3 Operation procedure Procedures must be conducted with a patient placed on a wooden chair or wooden couch
21. vel 4 Procedure duration is about 10 30 minutes Procedure duration is about 10 15 minutes Procedures are conducted or once in two days or daily The treatment course consists of 10 15 procedures Patients feelings during the procedure include smooth wind blowing mild noise and cracking rising hair and ozone smell The therapy must be conducted in a ventilated room with the comfortable air temperature of at least 18 centigrade It is highly desired to avoid much dust and high humidity in the room 5 3 3 Local franklinization Before therapy read carefully Section 5 3 The procedure is usually conducted during the bandaging For local franklinization the electrode of the corresponding form and size is put either above the lesion area wound ulcer or above the corresponding reflexogenic area collar area lumbar zone mammary glands etc Depending on the place of exposure a patient stays either lying on a wooden couch or sitting on a chair The procedure is conducted with the naked part of the body being franklinized The wound or ulcer skin surface must be cleaned from crust pus rejected masses treated with disinfecting solution and dried with a sterile cloth For the local franklinization the accessories A and C are used The special electrode C is fixed 5 7 cm off the skin surface above 18 the exposed naked part of patient s body so that a patient will feel smooth blow of the wind The polarizing plate
22. y and consult the doctor The recurrent procedures are recommended once the cause for recrudescence is revealed 7 MAINTENANCE The module does not need any additional calibration or maintenance WARNING all the maintenance operations must be done when the module is off IT IS NOT ALLOWED to open and repair the module and its accessories to use the module for purposes other than intended or not according to the e present User manual and the module passport Warranty package is valid if the module had been used according to the Passport User manual and Application recommendations it had not been updated repaired disassembled by unauthorized specialists if it had not been damaged as a result of inappropriate use and if the whole delivery set the main module and all the accessories shall is full and the seal is not removed The module cannot be treated as defective or damaged if a patient has a disease that is in the list of contraindications If there are defects during the warranty period time not arising due to the customer s fault you can contact the manufacturer CIT NELIAN Verkhniya Pervomayskaya str 29 office 302 105624 Moscow Russia Sales department 7 495 5 18 2541 7 925 518 2541 Tech support depatrment 7 926 747 5551 www nelian ru mail nelian ru alternative e mail cit nelian gmail com SKYPE name Iv Pavel Ivanov Pavel CIT NELIAN 24