Home

C-Series AS-i Master Module

image

Contents

1. ssrennnnzzennanzznnenznnnnnnzznnnnzzznnanzznznnzznmnnzznn 9 3 3 General safety information aanaaaaanaanaanann nnnnnnnunnnnnnunnnnnnnnnnnnunnannnnnnannaaan 9 3 4 Safety Guidelines for Hazardous Locations ss sseeseeneennnzennznnznnnnzzznz 9 3 4 1 Special Conditions for Hazardous Locations Use in Europe ssesensenennnzonenenza 10 3 5 Disposal i dh de cece E ES 10 4 Technical Specifications aa2naaaaanvansnnnnnnnnnnnnnnnnnnnnnnnnnnnunnannunnnan 11 4 1 PENES L e E E A E EEA E E T AE 11 4 2 Instructions for cleaning aa2aaanaanaann nn nannunnnunnnnnnnnunnnunnunnnunnunnnunnunnnnnnnnnnn 12 5 DescCriptiohns1 2 21 2 2224n2iinnsninnasunainnannnanunnnnnnnndunnnnnanDdninNUNiNNANANDUNANNANANERARA 13 5 1 LED Indicators 11 2 1anksliidanalnasiidansnuuinnnudu skn uannguuauanu u nunnnnunbunkunnu unnunnunannunguni 13 5 2 Connection of the AS i Master seseennnzznnnnnnznnzunzznnzunzznnennzzntunzznnzznzznznn 13 5 2 1 Connection samples for the AS i power SUpply aaaaaaaaaazaanaanan nannnnnnnanannannnnannnnannnnannn 13 5 3 Display and Operating Elements 2aa2naanaaa aan nn nnnnnnnannnnnnunnnnnnnnnnnnnnn 14 6 Configuration 2 i isiisassidin i adn nasninanandinnunanannundand a nddagnanannanaanunaananninu unnkar 15 6 1 VO Data Interpretation sisa i a 15 6 2 Output Input Data Mage i ea p 15 6 3 Analog Output Input Data Image 2 a2aauaananvannannnnanannnnnnnan
2. Master Module f Bint demann 9 Your opinion is important to us Please give us an opportunity to hear your suggestions wishes and criticisms re garding this Manual We read every note or comment no matter how small and incorporate them into the documentation whenever possible Fill out the form on the following page and fax it to us or send your remarks sug gestions for improvement etc to the following address Bihl Wiedemann GmbH Technical Support FloBworthstr 41 D 68199 Mannheim Germany Phone 49 0 621 33 99 6 0 Fax 49 0 621 33 9 22 39 eMail mail bihl wiedemann de Fax reply Bihl Wiedemann GmbH Date Technical Support Fax No 49 0 621 33 9 22 39 eMail mail bihl wiedemann de From Firm Name Dept Street Position City Tel Fax eMail Which manual are you using Title Publication date My opinion of the manual Design Yes Partly No Is the table of contents clearly laid out D o o Are the illustrations graphics comprehensible meaningful o o 1 Are the text explanations for the illustrations sufficient D o o Does the quality of the images meet your expectations D o o Does the pagination encourage rapid finding of information 1 o 1 2 Subject to technical modifications no responsibility is accepted for the accuracy of this information Bihl Wiedemann GmbH Internet www bihl wiedemann de Flosswoerthstr 41 D 68199 Mannheim phone 49
3. 621 33 996 0 fax 49 621 3 39 22 399 Issue date 16 4 2015 Issue date 16 4 2015 C Series AS i Master Module L At demann Your opinion is important to us Content Yes Partly No f l 2 Are the formulations technical terms understandable o O O 2 Are the examples relevant7 o o o 2 Is the Manual easy to handle oO o o FRA Is there important information missing If yes explain 1 o o Comments Subject to technical modifications no responsibility is accepted for the accuracy of this information Bihl Wiedemann GmbH 23 Internet www bihl wiedemann de Flosswoerthstr 41 D 68199 Mannheim phone 49 621 33 996 0 fax 49 621 3 39 22 399 Bihl Wiedemann
4. 996 0 fax 49 621 3 39 22 399 C Series AS i Master Module L Bi hl a A A Ho Wiedemann Symbol catalog Information This symbol indicates important information Attention This symbol warns of a potential failure Non compliance may lead to interruptions of the device the connected peripheral systems or plant potentially leading to total mal functioning Warning This symbol warns of an imminent danger Non compliance may lead to personal inju ries that could be fatal or result in material damages and destruction Abbreviations Information Additional information can be found in section lt Glossary gt 6 Subject to technical modifications no responsibility is accepted for the accuracy of this information Bihl Wiedemann GmbH Internet www bihl wiedemann de 7 Flosswoerthstr 41 D 68199 Mannheim phone 49 621 33 996 0 fax 49 621 3 39 22 399 Issue date 16 4 2015 Issue date 16 4 2015 C Series AS i Master Module Bihl cea e Wiedemann 2 1 2 2 2 3 Ho 2 4 O Il General Product information This system manual applies to the following Bihl Wiedemann GmbH equipment C Series AS i Master Module BW3023 AS i master module for compactRIO Tab 2 1 Product description and intended use The BW3023 is an AS interface master according to specification 3 0 It is also backward compatible because previous specifications 2 0 and 2 1 are support ed as well It e
5. Bihl ka Wiedemann BW 3023 0D 0 AS i powered 1 AS i active 2 prj mode 3 config error 0 1 2 3 4 AS Interface Master AS i 3 0 specification en svstem manual 3023 pdf Revision 1 6 jision 2015 04 16 Subject to modifications without notice Generally this manual refers to products without mentioning existing patents utility models or trademarks The absence of any such references does not indicate that a product is patent free Bihl Wiedemann GmbH Flosswoerthstr 41 D 68199 Mannheim Issue date 16 4 2015 C Series AS i Master Module Bihl we t Wiedemann Table of contents C Series AS i Master Module 1 Svmbol Catalog iii aids ua si kd dsetiEoztijiw 6 1 1 Abbreviation si ii aa case ada Kana bons ma aa ea ana asa at 6 2 General i E a ep 7 2 1 Product IN Ormatlon 2 7 1 1 12 a2asslisndsasndnbasakaddas nsnna iaksnn ub nanasnnanannannandana anununandin 7 2 2 Product description and intended USE 2222aaa2nvaaanns nsnsnnnnsnunnsnunnnnnunnann 7 2 3 Conformity statement auaa2naanaaaaaav nnannnannnnnnnnnnannnnnnnnnnnnnunanunnanannnnanann naan 7 2 4 Certification according to EN ISO 9001 2008 ssseesseennennzzenzennnnzenazznzz 7 2 5 Bihl Wiedemann hotline aannaaaaaaaannnna nnnunnnnnnnnunnnnnnnnununnnnnnunnnnnnnnnnnnnnnnn nana 8 3 Satetv iii ii a e atin etek 9 3 1 intended USE iii E aa a a a Sa 9 3 2 No user serviceable partS
6. Wiedemann GmbH 1 5 Internet www bihl wiedemann de Flosswoerthstr 41 D 68199 Mannheim phone 49 621 33 996 0 fax 49 621 3 39 22 399 C Series AS i Master Module 7 Bihl se ss Wiedemann 6 3 Analog Output Input Data Image AODI AIDI Adresse 215 214 213 212 211 210 29 98 97 26 25 24 23 22 21 90 0x00 Slave 0 15t Channel 0x02 Slave 0 2 Channel 0x7E Slave 15 4 Channel OxFE Slave 31 4 Channel Tab 6 5 6 3 1 Execution Control Flags EC Flags EC Flags Address 215 214 213 212 211 210 29 98 97 26 25 24 93 22 21 20 0x0 Pok OR APF NA CA AAv AAs SO Cok Tab 6 6 Cok ConfigOk So LDS O AAs AutoAddressAssign AAv AutoAddressAvailable CA ConfigurationActive NA NormalOperationActive APF APF OR OfflineReady Pok PeriperyOk 6 3 2 Slave Lists LAS LDS LPS LPF Address 215 214 213 212 211 210 29 98 97 26 25 24 93 22 21 20 0x0 s15 s14 s13 s12 s11 s10 s9 s8 s7 s6 s5 s4 s3 s2 s1 sO 0x2 s31 s30 s29 s28 s27 s26 s25 s24 s23 s22 s21 s20 s19 s18 s17 s16 0x4 s15b s14b s13b s12b s11b s10b s9b s8b s7b s6b s5b s4b s3b s2b s1b s0b 0x6 s31b s30bjs29b s28b s27b s26b s25b s24b s23b
7. a slave to the AS i network 2 Ifthe slave address is zero the status list should look like this Slave List f 1 x 7 Subject to technical modifications no responsibility is accepted for the accuracy of this information Bihl Wiedemann GmbH 1 9 Internet www bihl wiedemann de Flosswoerthstr 41 D 68199 Mannheim phone 49 621 33 996 0 fax 49 621 3 39 22 399 C Series AS i Master Module oprane f Wiedemann 7 4 7 5 20 oar Bihl Select Slave0 within the Old Address control Select the new address e g Slave2 within the New Address control Click the button Change Slave Address If the indicator Result Code is 0 address assignment was successful Abbreviations used within the Status List Control X O K The configuration data for the detected AS i slave matches the stored configuration data D Detected Only An AS i slave is detected at this address but it was not stored before P Projected Only An AS i slave was stored at this address but it was not detected C Type Conflict The configuration data for the detected AS i slave does not match the stored configuration data The actual exiting con figuration of the connected AS i slave is displayed F Periph Fault The AS i slave has a peripheral error A Duplicate Addr Two AS i slaves use the same address Protected Operating Mode Only those slaves shall be activated which are bot
8. accordance to its intended use Warning If the equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired No user serviceable parts Warning No user serviceable parts inside Do not open General safety information Warning Safety and correct functioning of the device cannot be guaranteed if any operation other than described in this operation manual is performed Connecting the equipment and conducting any maintenance work under power must exclusively be performed by appropriately qualified personnel In case a failure cannot be eliminated the device must be taken out of operation and inadvertently operation must be prevented Repair work must be performed by the manufacturer only Additions or modifications to the equipment are not permitted and will void the warranty Information The operator is responsible for the observation of local safety standards 3 4 Safety Guidelines for Hazardous Locations The BW3023 is suitable for use in Class l Division 2 Groups A B C D T4 hazardous locations Class Zone 2 AEx nA IIC TA and Ex nA IIC T4 hazard ous locations and nonhazardous locations only Follow these guidelines if you are installing the BW3023 in a potentially explosive environment Not following these guidelines may result in serious injury or death Subject to technical modifications no responsibility is accepted for the accuracy of this information Bi
9. fications no responsibility is accepted for the accuracy of this information Bihl Wiedemann GmbH Internet www bihl wiedemann de 7 Flosswoerthstr 41 D 68199 Mannheim phone 49 621 33 996 0 fax 49 621 3 39 22 399 Issue date 16 4 2015 Issue date 16 4 2015 C Series AS i Master Module L att demann 4 Technical Specifications 4 1 Data sheet Article No BW3023 AS i 3 0 Master for Compact RIO and Labview Function AS i Scope Diagnostics which go far beyond the standard diagnostics facili tate the simple detection of the occasionally occurring configura tion errors and further irritations towards the AS i communication AS i I O data and status information is mapped into the PLC processor s I O data So in case of an error the down time of machines can be mini mized or you can initiate preventive maintenance Article No BW3023 AS i Operating current approx 40 mA out of AS i approx 50 mA out of the backplane Operating voltage AS i voltage 29 5 31 6 Vpc AS i cycle time 150 us number of slaves 2 Total power dissipation max 1 5 W Display LED AS i powered green on AS i voltage O K LED AS i active green AS i normal operation active LED prj mode yellow configuration mode active LED config error red on at least 1 configured AS i slave is missing or at least 1 detected AS i Slave is not configured or for at least 1 configured and detected AS i slave the actual c
10. h members of the list of detect ed slaves LDS and members of the list of projected slaves LPS and whose configuration data image CDI value equals the permanent configuration data PCD value for that specific slave 1 Follow steps 1 5 of section lt Configuration Modes to bring the AS i network to Configuration mode 2 Click the Operation Mode control to change to Protected Mode Operation Mode Protected Configuration Subject to technical modifications no responsibility is accepted for the accuracy of this information Bihl Wiedemann GmbH Internet www bihl wiedemann de 7 Flosswoerthstr 41 D 68199 Mannheim phone 49 621 33 996 0 fax 49 621 3 39 22 399 Issue date 16 4 2015 Issue date 16 4 2015 C Series AS i Master Module Bihl 2 Wiedemann 8 Appendix Codes indicated by the Display Bihl Wiedemann AS i error codes and warnings are in the range Range 389000 to 389099 Errors explanations can be found with the NI LabVIEW envi ronment by clicking Help Explain Error A list of error codes is shown below Code Name Description 389000 asiErrorAnaloginvali dAddress Slave address for the analog read or write is invalid Solution Specifv an address in the range of 0 to 31 389001 asiErrorAnaloginvalid DataLength The data length of four 16 bit analog channel is out of range Solution Make sure the data length is within 8 bvtes 389002 asiErrorAnalogO
11. hl Wiedemann GmbH 9 Internet www bihl wiedemann de Flosswoerthstr 41 D 68199 Mannheim phone 49 621 33 996 0 fax 49 621 3 39 22 399 C Series AS i Master Module A 3 4 1 3 5 h lt Bihl L Wiedemann Caution Do not disconnect l O side wires or connectors unless power has been switched off or the area is known to be nonhazardous Do not remove modules unless power has been switched off or the area is known to be nonhazardous Substitution of components may impair suitability for Class I Division 2 For Zone 2 applications install the system in an enclosure rated to at least IP54 as defined by IEC 60529 and EN 60529 Special Conditions for Hazardous Locations Use in Europe This equipment has been evaluated as x 3G ExnAliC T4Ge equip ment under DEMKO Certificate No 14 ATEX 1413X and IECEx Certificate No IECEx UL 14 0112X Each module is marked II 3G and is suitable for use in Zone 2 hazardous locations If you are using the BW3023 in Gas Group IIC hazardous locations or in ambient temperatures of 40 C lt Ta lt 70 C you must use the device in a chassis that has been evaluated as EEx nA IIC T4 Ex nA IIC T4 or Ex nL IIC T4 equipment Disposal Information Electronic waste is hazardous waste Please comply with all local ordinances when disposing this product The device does not contain batteries that need to be removed before disposing it 1 0 Subject to technical modi
12. iedemann de 7 Flosswoerthstr 41 D 68199 Mannheim phone 49 621 33 996 0 fax 49 621 3 39 22 399 Issue date 16 4 2015 Issue date 16 4 2015 C Series AS i Master Module 6 2 Subject to technical modifications no responsibility is accepted for the accuracy of this information Configuration 1 O Data Interpretation Bihl 2 Wiedemann Fast changing data is directly located in the SPI frame while slower changing data and data which is only needed in special situations is located in the Command In terface Index Length Direction Carrier to Direction Carrier from Module Byte Module 0 16 Reserved Reserved 16 32 Output Data Image ODI Input Data Image IDI 48 256 Analogue Output Data Analogue Input Data Image AIDI Image AODI 304 2 Reserved Execution Control Flags EC Flags 306 2 Reserved Reflected Hl Flags 308 8 Reserved List of active slaves LAS 316 8 Reserved List of detected slaves LDS 324 8 Reserved List of projected slaves LPS 332 8 Reserved List of peripheral faults LPF 340 40 Command Interface Command Interface 380 4 Checksum Checksum 384 Tab 6 3 Output Input Data Image ODI IDI Adresse 215 214 213 212 211 210 29 28 27 96 25 24 23 22 21 20 0x00 Slave 3 Slave 2 Slave 1 Slave 0 0x02 Slave 7 Slave 6 Slave 5 Slave 4 Ox 0 Slave 3b Slave 2b Slave 1b Slave 0b Ox1E Slave 31b Slave 30b Slave 29b Slave 28b Tab 6 4 Bihl
13. n Otherwise off Tab 7 8 2 Ifthe AS i network is sufficiently powered AS i powered AS i active prj mode config error On On If configuration mode is active If there is config LED is on Otherwise off error LED is on Otherwise off Tab 7 9 O On the VI Frontpanel press the the Operation Mode switch and notice your modules being marked in the address table then press the Store Actual Configuration button to turn OFF the Config Error LED Configuration Mode All slaves except the slave with zero address that are members of the list of de tected slaves LDS shall be automatically detected and activated in the above mentioned way according to AS i specification Configuration mode is demonstrated in both shipping examples referenced in section lt Examples of address assignment gt The AS i C Series module can be placed into configuration mode by completing the following steps 1 Connect the AS i C Series module as described in section lt Connection of the AS i Master gt 2 Open the AS i RT Basic Ivproj example Subject to technical modifications no responsibility is accepted for the accuracy of this information Bihl Wiedemann GmbH 1 7 Internet www bihl wiedemann de Flosswoerthstr 41 D 68199 Mannheim phone 49 621 33 996 0 fax 49 621 3 39 22 399 C Series AS i Master Module 18 Bihl i Wiedemann 3 Verifv that your cRIO i
14. nables configuration control and diagnosis of up to 31 single slaves or 62 A B slaves via LabVIEW Fast changing data such as I O data or execution control flags is directly located in the SPI frame while slower changing data and data which is only needed in special situations is located in the command interface The LEDs located on the module indicate the current module status configura tion errors or peripheral faults and the activity on AS i Diagnostics which go far beyond the standard diagnostics facilitate the simple detection of the occasionally occurring configuration errors and further irritations towards the AS i communica tion So in case of an error the down time of machines can be minimized or you can initiate preventive maintenance The BW3023 is suitable for use in Class Div 2 Groups A B C D T4 hazard ous locations Class Zone 2 AEx nA IIC TA and Ex nA IIC T4 hazardous loca tions and nonhazardous locations only Conformity statement The C Series AS i Master Module has been developed and manufactured in ac cordance with the applicable european standards and directives Information The corresponding conformity statement can be found at the very beginning of this system manual Certification according to EN ISO 9001 2008 The manufacturer of the product possesses a certified quality assurance system in accordance with ISO 9001 Information The current certificate can be viewed in internet http w
15. nnnnnnnnnnnannunnuna 16 Subject to technical modifications no responsibility is accepted for the accuracy of this information Bihl Wiedemann GmbH 3 Internet www bihl wiedemann de Flosswoerthstr 41 D 68199 Mannheim phone 49 621 33 996 0 fax 49 621 3 39 22 399 C Series AS i Master Module L Bint demann 6 3 1 Execution Control Flags EC Flags aaaaaanaanaaavnnnnnnnnnnnnnnnnunununnnnnunununununununununnnnnunun 16 6 3 2 Slave Lists c ccecceesesseeeseeceeeeeeeeeeeseseneeneeeeseesaenaasaeeseecaeeseeeessaesseeeeesaesaesenesaeeseesaseneeness 16 7 Operating the AS abe cscccscesscesccccsseescestenescncccced estes cteccecesveceutesindeewecion 17 7 1 Master Start U p iii 7217 11 sa a a a d 17 7 2 Configuration Mode ssresennnnznnznnznnnnnnnnnnnnnnznnnnnnnnnnannnnnmnannnmanzmntmnazan 17 7 3 Examples of address assignment sssssrennnnzznnnnzzznnzanzennanzzznnanzzmnnnzzzz 19 7 3 1 Example of automatic address assignment ssensenzznnnnnzanznnnnnzenznnznnnanzanznnenzznznn 19 7 3 2 Example of manual address assignment ssrssnnnnnnnzznnannnnnnznnannnznnannnnnnznzannnnnnnnnnzz 19 7 4 Abbreviations used within the Status List Control 2aaaaaaavavsvsura 20 7 5 Protected Operating Mode sssenrenzznzznnznnnznnznnnnanzenannnzanznnanznnnnnnnnzznaz 20 8 Appendix Codes indicated by the Display 2a2anaanvnvvnssnunuunr 21 9 Your opinion is importan
16. odule Bihl san Wiedemann 7 3 7 3 1 7 3 2 Programming the Address in Case of Configuration Errors 1 Click the button Store Actual Configuration to store the current AS i net work configuration for all connected slaves then repeat step 2 5 from above Erasing the Slave Address 1 Remove a slave from the AS i network 2 The status of this slave in Slave List indicator should change to P Pro jected Only 3 Click the button Store Actual Configuration to delete the address from the module Automatic Address Assignment shall be processed only if 1 the Master module execution control mode is the protected mode 2 the Auto_Address_Enable mode is ON 3 the Auto Address Assign mode is set and If one and only one configured slave is not detected Examples of address assignment Example of automatic address assignment 1 Select an existing Slave e g Slave1 within the Old Address control Slave List F IX 1 2 _ Select SlaveO within the New Address control 3 Click the button Change Slave Address The status List should change like this Slave List D JO pari Remove the slave from the AS i network Click button Operation Mode to change to protected mode Connect this slave back to the AS i network Address 1 is assigned to this slave automaticallv Slave List A 5 6 7 0 x i Example of manual address assignment 1 Connect
17. onfiguration data does not match the nominal configuration data or the master is in the startup process flashing peripheral fault Environment Applied standards EN 61000 6 2 2005 EN 61000 6 4 2007 A1 2011 IEC 60079 0 6 edition IEC 60079 15 4 edition EN 60079 0 2012 4 A11 2013 EN 60079 15 2010 ISA 12 12 01 2013 UL 60079 0 6 Edition UL 60079 15 4 Edition CSA C22 2 No 223 1987 R2013 Operating temperature 40 C 70 C Storage temperature 40 C 85 C Intended environment for indoor use only Maximum altitude for use 5000 m Maximum relative humidity 90 non condensing Pollution degree of the intended 1 environment Protection category housing IP20 acc EN 60529 only suitable for use in electrical operating rooms cabinets with IP54 minimum protection rating Voltage of insulation AS i to compactRIO gt 500 V 60 Vpc CAT Ch to Earth Isolation Article No BW3023 Weight 420 g Dimensions W H D in mm 23 71 89 Subject to technical modifications no responsibility is accepted for the accuracy of this information Bihl Wiedemann GmbH 1 1 Internet www bihl wiedemann de Flosswoerthstr 41 D 68199 Mannheim phone 49 621 33 996 0 fax 49 621 3 39 22 399 C Series AS i Master Module L Bint demann Attention Provision shall be made to prevent the rated voltage being exceeded by the transient disturbance of more
18. pera tionTimeout Analog read or analog write timed out Solution Increase timeout and ensure AS i Commit vi has been called 389003 asiErrorCommandinval idRequestLength Command request size is out of range Solution Make sure the length of command request is smaller than 39 bytes 389004 asiErrorCommand Timeout Timeout occurred waiting for the command response Solution Increase timeout and check hardware connection 389005 asiErrorDigitallnvali dAddress Slave address for digital read or digital write is invalid Solution Specify an address which is in the range of 0 to 63 389006 asiErrorDigitallnvalid Data Digital data value is invalid Solution Specify a value in the range of 0 to 15 389007 asiErrorDigitallnvalid DatalmageLength Digital data image size is out of range Solution Make sure the length of digital data image is smaller than 33 bytes 389008 asiErrorSpiFrameData Fault CRC check failed between backplane and mod ule SPI communication may be corrupted by electrical noise Solution Reduce noise and con tact National Instruments if the error persists Subject to technical modifications no responsibility is accepted for the accuracy of this information Bihl Wiedemann GmbH 21 Internet www bihl wiedemann de Flosswoerthstr 41 D 68199 Mannheim phone 49 621 33 996 0 fax 49 621 3 39 22 399 C Series AS i
19. s connected properly by right clicking the target within your project and going to Connect 4 Open the front panel of the BW3023 AS i Commissioning vi AS i RT Basic lvproj Project Explo File Edit View Project Operate Tools Window Items Files besi xanxiiznim f e Project AS i RT Basic lvproj B My Computer i 57 Dependencies Build Specifications Add CANopen Utilities gt gt Utilities i gt Deploy Deploy All Arrange By Expand All Collapse All Find Project Items Rename Help Properties Remove from Project F2 Assigning an AS i Address in the Configuration Mode Assigning a Slave Address 1 Connect a new slave in the AS i network the state of this slave is showed in the Slave List indicator aPpon Subject to technical modifications no responsibility is accepted for the accuracy of this information Select the devices old address within the Old Address control Select the new address within the New Address control Click the button Change Slave Address If the indicator Result Code is 0 address assignment was successful Bihl Wiedemann GmbH Internet www bihl wiedemann de Flosswoerthstr 41 D 68199 Mannheim phone 49 621 33 996 0 fax 49 621 3 39 22 399 Issue date 16 4 2015 Issue date 16 4 2015 C Series AS i Master M
20. s22b s21b s20b s19b s18b s17b s16b Tab 6 7 1 Subject to technical modifications no responsibility is accepted for the accuracy of this information Bihl Wiedemann GmbH Internet www bihl wiedemann de Flosswoerthstr 41 D 68199 Mannheim phone 49 621 33 996 0 fax 49 621 3 39 22 399 Issue date 16 4 2015 Issue date 16 4 2015 C Series AS i Master Module L At demann 7 7 1 7 2 Operating the AS i The LabVIEW API ships with two examples AS i RT Basic lvproj and AS i FPGA Basic lvproj referenced throughout the rest of this Manual The ex amples can be located by the following steps 1 Open LabVIEW if not already opened 2 In LabVIEW click Help gt Find Examples and then search for AS i 3 Open the AS i RT Basic or AS i FPGA Basic project 4 For addition help click Help gt Bihl Wiedemann in LabVIEW to open the user manual Master Start Up O Connect the AS i module as described in section lt Connection samples for the AS i power supply gt and plug the AS i module into one slot of your pow ered cRIO chassis All LEDs of the module should be Off O Then if you run the example BW 3023 AS i Commissioning vi as described in section lt Configuration Mode gt some LED s should turn ON depending on the state of master 1 If the AS i network is not sufficiently powered AS i powered AS i active prj mode config error Off Off If configuration mode is active On LED is o
21. t tO uSl s00ssrennnnzannnnzznnnanznnanzznananznnza 22 4 Subject to technical modifications no responsibility is accepted for the accuracy of this information Bihl Wiedemann GmbH Internet www bihl wiedemann de Flosswoerthstr 41 D 68199 Mannheim phone 49 621 33 996 0 fax 49 621 3 39 22 399 Issue date 16 4 2015 Issue date 16 4 2015 as Bibl C Series AS i Master Module EC Declaration or conoy Ss Wiedemann EC Declaration of Contor rey Declaration of Conformity according to 2004 108 EC and 2011 65 EU BihltWiedemann GmbH Mannheim hereby declares under its sole responsibility that the products mentioned below are according to the listed harmonized standards or normative documents and where neccessary a competent body has been released Article No Description BW3023 ___ C Series AS i Master Module Applied harmonized EN 62026 2 2013 standards EN 61000 6 2 2005 AC 2005 EN 61000 6 4 2007 A1 2011 EN 61131 2 2007 A1 2011 EN 50581 2012 The products are marked by the CE sign in accordance with the EMC guideline Manufacturer Bihl Wiedemann GmbH FloRworthstrake 41 68199 Mannheim Deutschland Pe Bernhard Wiedemann Date 29 September 2014 Subject to technical modifications no responsibility is accepted for the accuracy of this information Bihl Wiedemann GmbH 5 Internet www bihl wiedemann de Flosswoerthstr 41 D 68199 Mannheim phone 49 621 33
22. than 140 of the peak rated voltage The system shall be mounted in an ATEX IECEx certified enclosure with a minimum ingress protection rating of at least IP54 as defined in IEC EN60529 and used in an environment of not more than pollution degree 2 The enclosure must have a door or cover accessible only by the use of a tool 4 2 Instructions for cleaning If you need to clean the module wipe it with a dry towel 1 2 Subject to technical modifications no responsibility is accepted for the accuracy of this information Bihl Wiedemann GmbH Internet www bihl wiedemann de 7 Flosswoerthstr 41 D 68199 Mannheim phone 49 621 33 996 0 fax 49 621 3 39 22 399 Issue date 16 4 2015 Issue date 16 4 2015 C Series AS i Master Module L Bi hl Description 5 2 5 2 1 O Il Wiedemann Description LED Indicators Indicator Color Description 7 AS i Master power AS i powered Green Ce Peripheral fault AS i active Green XE Normal operation active prj mode Yellow XE Configuration state config error Red 7 Config error occurred Tab 5 2 Connection of the AS i Master Connection samples for the AS i power supply AS i Master AS i Master AS i max 5 A TASISI power PELV according to EN rt SUSE supply 50178 Protective extra low voltage AS i Slave AS i Slave ymax 8A Si PELV according to EN 50178 z p peer l AS i Slave 14441 supply Protective e
23. ww bihl wiedemann de Subject to technical modifications no responsibilitv is accepted for the accuracv of this information Bihl Wiedemann GmbH 7 Internet www bihl wiedemann de Flosswoerthstr 41 D 68199 Mannheim phone 49 621 33 996 0 fax 49 621 3 39 22 399 C Series AS i Master Module L Bint demann General 2 5 Bihl Wiedemann hotline If problems or faults occur which you cannot rectify yourself and which are not de scribed in this users manual please contact the Bihl Wiedemann GmbH service hotline Phone 49 0 621 33 996 0 Central Fax 49 0 621 33 92 22 39 mail info bihl wiedemann com web www bihl wiedemann com Please make a note see lateral label of the following details before calling Bihl Wiedemann GmbH Device type Art no Ident no Date of deliverv 8 Subject to technical modifications no responsibility is accepted for the accuracy of this information Bihl Wiedemann GmbH Internet www bihl wiedemann de 7 Flosswoerthstr 41 D 68199 Mannheim phone 49 621 33 996 0 fax 49 621 3 39 22 399 Issue date 16 4 2015 Issue date 16 4 2015 C Series AS i Master Module L Bi hl W p Pp gt o w gt Ho Wiedemann Safety Intended use Warning This symbol warns of a possible danger The protection of operating personnel and the system against possible danger is not guaranteed if the control interface unit is not operated in
24. xtra low voltage _ Pie Attention In the wiring schemes above the current through the AS i master must not exceed 5 A 10 w 0 2 2 5 mm GO EH 0 2 2 5 mm AWG 24 2012 ii H Temperature rating for cable Use copper conductors only Subject to technical modifications no responsibility is accepted for the accuracy of this information Bihl Wiedemann GmbH 1 3 Internet www bihl wiedemann de Flosswoerthstr 41 D 68199 Mannheim phone 49 621 33 996 0 fax 49 621 3 39 22 399 C Series AS i Master Module L Bint demann 5 3 Display and Operating Elements BW 3023 D 0 AS i powered 1 AS i active 2 prj mode 3 config error A AS Interface Master PINs 0 1 AS i AS i Connection AS i circuit 2 3 AS i PWR AS i PWR Supply voltage AS i circuit 4 FE Functional earth LEDs 3 config error Configuration error At least one configured slave is missing at least one detected slave is not projected or for at least one projected and detected slave the actual con figuration data does not match the nominal configuration data 0 AS i powered The AS i circuit is sufficiently powered 1 AS i active Normal operation active 2 prj mode The AS i master is in configuration mode 1 4 Subject to technical modifications no responsibility is accepted for the accuracy of this information Bihl Wiedemann GmbH Internet www bihl w

Download Pdf Manuals

image

Related Search

Related Contents

Questionnaire pour constituer un passeport de communication  StarTech.com 3m (10 ft) Long Apple 30-pin Dock Connector to USB Cable for iPhone / iPod / iPad with Stepped Connector  (HILS) Using VISSIM Tutorial  User's Manual  

Copyright © All rights reserved.
Failed to retrieve file