User Manual - Escoglobal.com
Contents
1. MENU 2 2 1 Settings SET TIME HH MM WARM UP TIME XX MINUTES SETTINGS POSTPURGE TIME XX MINUTES INNER DOOR TIMEOUT XX SECONDS MEASUREMENT UNIT ENGLISH METRIC NORMAL MODE SET MODE ADVANCED MODE MAINTENANCE MODE FIELD CALIBRATION DOWNFLOW CALIB RESET CALIBRATION NEW ADMIN PIN XXXX NEW FAN PIN XXXX ADMIN SETTINGS RESET B H M RESET UV H M RESET DEFAULT ALM MUTE DURATION XX SECONDS Users may use the settings menu function to customize the operation of the isolator to meet specific application requirements The settings menu can be entered using both FAN PIN and ADMIN PIN 2 2 1 1 Set Clock Time Users can set the time by increasing decreasing the hour and minute values The correct time will be maintained even after the unit is turned off MENU m SETTINGS gt 2 2 1 2 Warm Up Time There will be a period of warm up before the fan is fully functioning This is to ensure that the sensors the blower and the control system are stabilized as well as purging the work zone of contaminants The default setting is 3 minutes and the user can set it between 3 to 15 minutes MENU SET TIME
2. or SETTINGS WARM UP TIME HH MM XX MINUTES isociean 2 2 1 3 PostPurge Time After the user switches off the isolator blower there will be a post purge period to ensure that all contaminants are purged from the work zone The default setting is zero minute disable and user can set it between 0 to 15 minutes However it is recommended to purge the isolator for around 3 minutes after the work is complete MENU SETTINGS POSTPURGE TIME XX MINUTES 2 2 1 4 Inner Door Timeout The inner door cannot be left open for more than a certain period This period can be set in the inner door timeout option The default timeout period is 30 seconds MENU SETTINGS INNER DOOR TIMEOUT XX SECONDS 2 2 1 5 Measurement Unit Using this option the user can select the unit in which air velocity is measured and displayed The user can choose between metric m s and imperial fpm ENGLISH MENU SETTINGS MEASUREMENT UNIT METRIC 2 2 2 Setting Mode The isolator has three working mode The menu can be entered using both FAN PIN and ADMIN PIN gt NORMAL MODE MENU E SET MODE ADVANCED MODE p MAINTENANCE MOD
3. HPI AN1 0 6 1 0 4 1 5 6 1 5 4 1 0 6 1 0 4 1 5 6 1 5 4 2 0 6 2 0 4 2 5 6 2 5 4 2 0 6 2 0 4 2 5 6 2 5 4 3 0 6 3 0 4 3 5 6 3 5 4 3 0 6 3 0 4 3 5 6 5 Model with S indicate that the isolator have sharps container and the hole for the container the work zone 2 Safety Warning e Anyone working with on or around this equipment should read this manual Failure to read understand and follow the instructions given in this documentation may result in damage to the unit injury to operating personnel and or poor equipment performance e Anyinternal adjustment modification or maintenance to this equipment must be undertaken by qualified service personnel e The use of any hazardous materials in this equipment must be monitored by an industrial hygienist safety officer or some other suitably qualified individual e Before you process you should thoroughly understand the installation procedures and take note of the environmental electrical requirements e Inthis manual important safety related points will be marked with the symbol AN Ifthe equipment is used in a manner not specified by this manual the protection provided by this equipment may be impaired 3 Limitation of Liability The disposal and
4. AN1 0 HPI AN1 S 6N1 0 HPI 6N1 5 in accordance with the following directives 2006 95 EEC The Low Voltage Directive and its amending directives 92 31 EEC The Electromagnetic Compatibility Directive and its amending directives has been designed to comply with the requirement of the following Harmonized Standard Low Voltage EN 61010 1 2010 EMC EN 61326 1 2006 Class B More information may be obtained from Esco s authorized distributors located within the European Union A list of these parties and their contact information is available on request from Esco XQ Lin Group CEO ESCO This Declaration of Conformity is only applicable for 230V AC 50 60Hz units Pharmacy Isolator ECCO viii Declaration of Conformation In accordance to EN ISO IEC 17050 1 2010 We Esco Micro Pte Ltd of 21 Changi South Street 1 Singapore 486777 Tel 65 6542 0833 Fax 65 6542 6920 declare on our sole responsibility that the product Category Pharmacy Compounding Aseptic Isolator Brand Isoclean Model HPI 4 1 0 4 1 S HPI 6 1 0 HPI 6 1 S in accordance with the following directives 2006 95 EEC The Low Voltage Directive and its amending directives 92 31 EEC The Electromagnetic Compatibility Directive and its amending directives has been designed to comply with the requirement of the following Harmonized Standard Low Voltage EN 61010 1 2010 EMC EN 6
5. calibrated WZN Nominal pressure value in work zone calibrated PTN Nominal pressure value in pass through chamber calibrated WZIDO Work zone inner door open pressure value calibrated PTIDO Pass through chamber inner door pressure value calibrated CONSTANT Sensor constant ADC DFMIN ADC for field calibrated minimum downflow ADC DFNOM ADC for field calibrated nominal downflow ADC DF ADC for actual downflow velocity reading ADC DFO ADC for calibrated zero point downflow ADC DF1 ADC for minimum downflow ADC DF2 ADC for nominal downflow ADC WZONE ADC actual pressure value in work zone ADC WZO ADC zero point pressure value in work zone calibrated ADC WZN ADC nominal pressure value in work zone calibrated ADC WZIDO ADC inner door open pressure value in work zone calibrated ADC PTHRU ADC actual pressure value in pass through chamber ADC PTO ADC zero point pressure value in pass through chamber calibrated ADC PTN ADC nominal pressure value in pass through chamber calibrated ADC PTIDO ADC inner door open pressure value in pass through chamber calibrated WZONE MAX Maximum limit value of Pressure sensor on work zone chamber RQ PRES DF Differential value between pressure sensor on main chamber and Pass Through Pharmacy Isolator ECCO isociean Chapter 3 Basic Isolator Operation 3 1 Starting and Shutting Down the Isolator 3 1 1 Turning on the Isolator 1 Turnon the fan by pressing the FAN button Input the Fan PI
6. the isolator can be turned on and off without requiring PIN however to access the menu the user is still required to enter the FAN PIN 0000 MENU ADMIN SETTINGS NEW FAN PIN gt XXXX 2 2 4 5 Reset B H M This option is used to reset the blower hour meter The blower hour meter indicates how long the blower has been in operation There s no maximum value in blower hour meter The counter value can be checked while in the diagnostic mode The value can also provide some help in setting up maintenance schedule MENU ADMINSETTINGS RESET B H M 2 2 4 6 Reset UV H M This option is used to reset the UV lamp hour meter The UV lamp hour meter indicates how long the UV lamp has been in operation Maximum counter is set at 2000 hours 10096 The counter value can be checked while in the diagnostic mode Please reset the UV lamp hour meter after each UV lamp replacement MENU ADMINSETTINGS RESET UV H M 2 2 4 8 Reset Default User can reset the default setting by choosing this option The features being reset are warm up period 3 minutes post purge period 0 minute measurement unit Metric ADMIN PIN 0009 Filter Life Display disabled and FAN PIN 0000 Note that the calibration settings cannot be reset as it may cause the isolator to operate in an unsafe manner The hour me
7. 6 inches from clean items materials e Place air turbulence generating equipment such as centrifuges blenders or sonicators towards the back of the isolator Stop other work while any of this equipment is in operation 3 3 Working Ergonomics On most occasions you would most likely be operating the HPI in sitting rather than standing posture There are some obvious advantages of the sitting posture e physiological energy cost and fatigue involved in sitting are relatively less e Sitting posture provides the body with a stable support However sitting position has some drawbacks too e working area available is fairly limited e Thereis a potential risk of being constrained the same posture for a long time e Sitting posture is one of the most stressful postures for one s back Therefore you should pay careful attention to the following guidelines in order to achieve comfortable and healthy working conditions Always ensure that your legs have enough legroom e Keep your lower back comfortably supported by your chair Adjust the chair or use a pillow behind your back whenever necessary Pharmacy Isolator ECCO e You should place your feet flat on the floor or on a footrest Don t dangle your feet and compress your thighs e You should keep varying your sitting position throughout the day at regular intervals so that you are never in the same posture for too long e Observe the following precautions with respect to
8. around outside cuff ring perimeter of the cuff ring Install the glove The hand portion must be inside the cuff ring This is how the Sleeve and glove assembly look after reversing and ready to installed on the HPI Ecco isociean 4 4 Sharps Container Removal Procedure Gasket Gasket _4 NER Sharps Disposal 5 Latch 1 Release the latch on both sides gently allow the base tray to swing downwards 2 Remove sharps container from mounting base secure container lid and disposed of through the proper procedures of the facility 3 Remove garbage container from base tray and empty the container Replace new sharps container or garbage container 5 Ensure container top is completely sealed against the gasket 4 5 Maintenance Service Log It is good practice and in some cases regulatory requirement to maintain a log of all maintenance work carried out on your cabinet Pharmacy Isolator ESCO isociean APPENDIX APPENDIX A LOG RECORD Cabinet Serial Number Person in Charge 1 Thislog record should be used by the operator to record any new agent virus bacteria germs that has been introduced to the cabinet during its operation problems encountered etc 2 decontamination procedure performed by either the user or the technician should be recorded down a
9. cases make sure that you wash the steel surface immediately afterwards with clean water and some liquid detergent Use a polyurethane cloth or sponge for washing Regularly cleaning the stainless steel surface can help you retain the attractive factory finish Check the cabinet s functionality e Check the isolator s mechanical functionality ex window opening lubricate if necessary e Check the isolator s electrical functionality ex fluorescent lamp replace if necessary e Check the isolator for any defect repair immediately Re certification All isolator must be re certified annually by a certified engineer See test report for recertification procedure Pharmacy Isolator ECCO 4 2 Glove Changing Procedure ziv Nl Norma operating condition ziv ENSE Pull glove and sleeve outsid glove and sleeve inside the the isolator isolator 21729 wist sleeve and tie up the sleeve with cable tie Place new glove into the sleeve Fold glove over cuff ring and install spring Procedure is complete Note You only have to use the Esco factory supplied sleeves and cuff ring You do not have to use the Esco factory supplied gloves One can just replace the gloves supplied by Esco with sterile medical disposable surgical gloves based on operator preference of material and size 4 3 Sleeve Changing Procedure insert the wrist end of the Stretch the wrist end and sleeve into the center of the wrap it
10. operating environmental conditions Servicing not authorized by Esco Usage that is not in accordance with product instructions Failure to follow the product instructions Failure to perform preventive maintenance Problems caused by using accessories parts or components not supplied by Esco Damage by fire floods or acts of God o Customer modifications to the product e Consumables such as filters HEPA ULPA carbon pre filters and fluorescent UV bulbs e Escois not liable for any damage incurred on the objects used or stored in Esco equipment If the objects are highly valuable user is advised to have in place independent external preventive measures such as connection to a centralized alarm system Factory installed customer specified equipment or accessories warranted only to the extent guaranteed by the original manufacturer The customer agrees that in relation to these products purchased through Esco our limited warranty shall not apply and the original manufacturer s warranty shall be the sole warranty in respect of these products The customer shall utilize that warranty for the support of such products and in any event not look to Esco for such warranty support Esco encourages all users to register their equipment online at www escoglobal com warranty or complete the warranty registration form included with each product ALL EXPRESS AND IMPLIED WARRANTIES FOR THE PRODUCT INCLUDING BUT NOT LIMITED
11. 1326 1 2006 Class B More information may be obtained from Esco s authorized distributors located within the European Union A list of these parties and their contact information is available on request from Esco XQ Lin Group CEO ESCO This Declaration of Conformity is only applicable for 230V AC 50Hz units Eccolisoclean Chapter 1 Product Information 1 1 Quick View 1 1 1 Esco Pharmacy Compounding Aseptic Containment Isolator HPI N Exhaust ULPA filter Front cover Esco Sentinel Gold microprocessor Pass thru outer door Stainless steel sliding tray Optional motorized support stand Casters Intake pre filter and ULPA filter Glove ports 10 Hinged access window with viewscreen 11 Optional sharps garbage disposal system for hazardous drugs 12 Optional exhaust carbon filter 9 ES Pharmacy Isolator ESCO 1 1 2 Esco Pharmacy Compounding Aseptic Isolator HPI P Exhaust ULPA filter Front cover Esco Sentinel Gold microprocessor Transfer chamber outer door Stainless steel sliding tray Optional motorized support stand Castors Intake filter Oval glove ports 10 Hinged access window with viewscreen 11 Optional sharps garbage disposal system o 90 5 OY UY TS C QJ NJ ES isociean Chapter 2 Sentinel Control System 2 1 Sentinel Control System LCD Menu Up Fan Socket Display Button Button Button Button Ecco c D AGN
12. E 2 2 2 1 Normal Mode The normal mode is activated by factory default In this mode all alarms and interlocks are enabled 2 2 2 2 Advanced Mode The advanced mode is used when the alarm is to be enabled It is disabled by default and the alarm enabling can only be done at the factory Please contact Esco if you want to enable the alarm 2 2 2 3 Maintenance Mode Maintenance mode should only be accessed by qualified personnel during maintenance In this mode all alarms are disabled and all interlocks are defeated 2 2 3 Field Calibration The purpose of calibration is to ensure the accuracy of the airflow display and alarm if present This involves measuring airflow with reference instrumentation and establishing reference between airflow sensor s on the isolator to the standard reference Calibration should only be carried out by trained personnel This section presents a brief overview of the calibration menu function For more information refer to test report MENU FIELD CALIBRATION gt DOWNFLOW CALIB __ RESET CALIBRATION 2 2 3 1 Downflow Calibration This option allows proper calibration and operation of the airflow sensor alarm 2 2 3 2 Reset Calibration This option allows the user to reset all value calibrated in the field and return it to the values gathered in factory calibration Pharmacy Isolator ECCO E 2 2 4 Admin Settings The a
13. N if asked if PIN 0000 This will start the warm up procedure default 3 minutes All buttons are diabled during warm up period 2 Theisolator is ready for work 3 1 2 Turning off the Isolator 1 Turn off the fan by pressing the FAN button Input the Fan PIN if asked if PIN 0000 This will start the post purge procedure default O minute All buttons are diabled during post purge period 2 Turn on the UV lamp when present to decontaminate the work area by pressing the UV button Leave the UV lamp on to make sure the decontamination is done effectively The UV lamp can only be turned on after the post purge procedure is finished 3 2 Working in the Isolator e Surface decontaminate the work area work surface back and side wall UV lamp before and after using the isolator e Allow the isolator to purge any contaminant by allowing the blower to operate at least 3 minutes before and after using the isolator e Surface decontaminate any item or apparatus with appropriate disinfectant before entering or exiting the work area e Place all items and apparatus the safe working area e While working in isolator move your hands slowly and in a controlled manner e The use of Bunsen burner inside the work zone is not recommended However if the use of Bunsen burner is unavoidable place the burner in the right side of the work zone e Place aerosol generating instruments as far inside the isolator as possible and at least 150 mm
14. OSTICS SentinelegoL3 0 MICROFROCESSOR CONTROL SYSTEM as 99 Visual Set Mute Down Lamp UV Alarm Diag Button Button Button Button 1 Fan Button o Turns on and turn off the fan 2 Lamp Button o Turns on and turn off the fluorescent lamps 3 Socket Button o Turns on and turn off the electrical socket retrofit kit o Themaximum rating of all the outlets in the cabinet is 5 A If overload the fuse will blow 4 UV Button o Turns on and turn off the UV lamp o UVlamp can only be activated when the sash window is fully closed Since the sash is capable of filtering UV rays users are protected from the harmful UV radiation 5 Up A and Down V Arrow Button o Move the menu options upwards and downwards o Increase and decrease corresponding value inside one of the menu options 6 Setor Mute or Diagnostic Button Proceed to the next step level or sequence inside the menu options o Enter diagnostic mode 7 Menu Button When you are entering menu options the alarm will sound to indicate that the microprocessor is not monitoring the operation of the isolator No further warnings will be given o To enter and exit from the menu options o Togo back to the previous level of the menu options Toaccess maintenance mode from error condition Pharmacy Isolator ECCO 2 2 Menu Options Please refer to the following diagram for complete reference to all menu options available
15. TO ANY IMPLIED WARRANTIES AND CONDITIONS OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN TIME TO THE TERM OF THIS LIMITED WARRANTY NO WARRANTIES WHETHER EXPRESS OR IMPLIED WILL APPLY AFTER THE LIMITED WARRANTY PERIOD HAS EXPIRED ESCO DOES NOT ACCEPT LIABILITY BEYOND THE REMEDIES PROVIDED FOR IN THIS LIMITED WARRANTY OR FOR SPECIAL INDIRECT CONSEQUENTIAL OR INCIDENTAL DAMAGES INCLUDING WITHOUT LIMITATION ANY LIABILITY FOR THIRD PARTY CLAIMS AGAINST YOU FOR DAMAGES FOR PRODUCTS NOT BEING AVAILABLE FOR USE OR FOR LOST WORK ESCO S LIABILITY WILL BE NO MORE THAN THE AMOUNT YOU PAID FOR THE PRODUCT THAT IS THE SUBJECT OF A CLAIM THIS IS THE MAXIMUM AMOUNT FOR WHICH ESCO IS RESPONSIBLE Pharmacy Isolator Ecco These Terms and Conditions shall be governed by and construed in accordance with the laws of Singapore and shall be subject to the exclusive jurisdiction of the courts of Singapore Technical Support Warranty Service Contacts USA 1 877 479 3726 Singapore 65 65420833 Global Email Helpdesk support escoglobal com Visit http www escoglobal com to talk to a Live Support Representative Distributors are encouraged to visit the Distributor Intranet for self help materials Product Appendix Warranty Listings Biological Safety Cabinets Laminar Flow Cabinets The warranty periods for BSC may vary by country Contact HEPA Filtered Cabinets except Streamline brand your local distrib
16. TORY DATE SERIAL amp OF 1 UNIT REVNO cech cui DESCRIPTION OF CHANGE REFERENCE EO IMBLEIMENTATIGN Ecco isociean Warranty Terms and Conditions Esco products come with a limited warranty The warranty period will vary depending on the product purchased beginning on the date of shipment from any Esco international warehousing location To determine which warranty applies to your product refer to the appendix below Esco s limited warranty covers defects in materials and workmanship Esco s liability under this limited warranty shall be at our option to repair or replace any defective parts of the equipment provided if proven to the satisfaction of Esco that these parts were defective at the time of being sold and that all defective parts shall be returned properly identified with a Return Authorization This limited warranty covers parts only and not transportation insurance charges This limited warranty does not cover e Freight or installation inside delivery handling damage If your product was damaged in transit you must file a claim directly with the freight carrier e Products with missing or defaced serial numbers e Products for which Esco has not received payment e Problems that result from o External causes such as accident abuse misuse problems with electrical power improper
17. Thank you for purchasing this Esco Pharmacy Isolator Please read this manual thoroughly to familiarize yourself with the many unique features and exciting innovations we have built into your new equipment Esco provides many other resources at our website www escoglobal com to complement this manual and help you enjoy many years of productive and safe use of your Esco products For Technical Service contact North America Esco Technologies Inc 2940 Turnpike Drive Units 15 16 Hatboro PA 19040 USA Toll Free USA and Canada 1 877 479 3726 Tel 215 441 9661 Fax 215 441 9660 us escoglobal com usa escoglobal com Rest of World Esco Micro Pte Ltd 21 Changi South Street 1 Singapore 486 777 Tel 65 6542 0833 Fax 65 6542 6920 www escoglobal com mail escoglobal com Esco HPI User Manual Version A Released May 2011 User Manual Isoclean Pharmacy Isolators Copyright Information Copyright 2011 Esco Micro Pte Ltd All rights reserved The information contained in this manual and the accompanying product is copyrighted and all rights are reserved by Esco Esco reserves the right to make periodic minor design changes without obligation to notify any person or entity of such change Isoclean and Sentinel are registered trademarks of Esco Material in this manual is provided for informational purposes only The contents and the product described in this manual including any appendix addendum attachmen
18. commend that you follow the maintenance schedule suggested hereunder in order to obtain optimal performance from your Esco HPI Description of Task to Perform Maintenance to be carried out every Day Week Month Quarter 1Year 2 Years Surface decontaminate the work zone HPI power up alarm verification Thoroughly surface decontaminate the drain pan Check the paper catch for retained materials V Clean the exterior surfaces of the V Clean the sash window Check all service fixtures where present for proper operation Inspect the HPI for any physical abnormalities or malfunction Clean up stainless steel surfaces with MEK V Re certification Change UV Lamp where present Change the fluorescent lamps 2 e lt WIN Re Hd o Hd a N Cleaning the Isolator e Clean the work surface and walls with appropriate disinfectant agent and soap water afterward e Clean the window using an appropriate disinfectant agent and glass cleaner afterward e Usea damp cloth to clean the exterior surface of the isolator particularly on the front and top in order to remove dust that accumulated there e Use clean water to finish the cleaning and wash away any residue of disinfectant agent soap water and glass cleaner e For removing stubborn stains or spots on the stainless steel surface make use of MEK Methyl Ethyl Ketone In such
19. dmin menu allows you to change both FAN and ADMIN PIN The reset blower and UV hour meter functions are usually used after you change the blower or UV lamp as they can easily give you the indication on when to do isolator maintenance While the reset default function will return the options in the settings menu to their factory settings 2 2 4 1 New ADMIN PIN default 0009 ADMIN PIN restricts access to some of the more delicate menu functions namely admin and field calibration which should only be accessed by a qualified personnel User must enter four digits ADMIN PIN before accessing these menus ADMIN PIN can also be used to switch to maintenance mode from error condition MENU gt ADMIN SETTINGS NEWADMINPIN XXXX 2 2 4 2 New FAN PIN default 0000 DISABLED FAN PIN restricts access to fan control and some parts of the menu settings and set mode User must enter four digit PIN before switching fan on or off As such it can restrict access to operating the HPI by unauthorized personnel It will also prevent unauthorized shutdown of the isolator when continuous operation is required Note that continuous operation is recommended for better safety Fan PIN is also needed to disable the alarm when the sash is fully raised and cleaning needs to be performed Setting the PIN to 0000 will disable this feature The FAN PIN is disabled by default When the FAN PIN is disabled
20. or emission of substances used in connection with this equipment may be governed by various local regulations Familiarization and compliance with any such regulations are the sole responsibility of the users Esco s liability is limited with respect to user compliance with such regulations Pharmacy Isolator ECCO 4 European Union Directive on WEEE and RoHS The European Union has issued two directives Directive 2002 96 EC on Waste Electrical and Electronic Equipment WEEE This product is required to comply with the European Union s Waste Electrical amp Electronic Equipment WEEE Directive 2002 96 EC It is marked with the following symbol Esco sells products through distributors throughout Europe Contact your local Esco distributor for recycling disposal Directive 2002 95 EC on Restriction on the use of Hazardous Substances RoHS With respect to the directive on RoHS please note that this hood falls under category 8 medical devices and category 9 monitoring and control instruments and is therefore exempted from requirement to comply with the provisions of this directive Ecco isociean vii Declaration of Conformation In accordance to EN ISO IEC 17050 1 2010 We Esco Micro Pte Ltd of 21 Changi South Street 1 Singapore 486777 Tel 65 6542 0833 Fax 65 6542 6920 declare on our sole responsibility that the product Category Pharmacy Compounding Aseptic Containment Isolator Brand Isoclean Model HPI
21. s well 3 Please also record any major maintenance procedure performed by the service technician for example parts replacement recertification etc Date Event User Signature Supervisor Signature In case of emergencies please call Name Cell Phone Number E mail APPENDIX B MANUAL REVISIONS REV NEW ECN NO
22. t or inclusion are subject to change without notice Esco makes no representations or warranties as to the accuracy of the information contained in this manual In no event shall Esco be held liable for any damages direct or consequential arising out of or related to the use of this manual es Table of Contents INTRODUCTORY PAGES i Table of Contents ii Manual Revision History iii Warranty Terms and Conditions V Introduction 1 Products Covered 2 Safety Warning 3 Limitation of Liability vi 4 European Union Directives on WEEE and RoHS vii Declaration of Conformity USER SECTION 1 1 1 Quick View 1 1 1 1 Esco Pharmacy Compounding Aseptic Containment Isolator HPI N 2 1 1 2 Esco Pharmacy Compounding Aseptic Isolator HPI P Chapter 2 Control System 2 1 Sentinel Control System 2 2 Menu Options 2 2 1 Settings 2 2 2 Setting Mode 2 2 3 Field Calibration 2 2 4 Admin Settings 2 3 Alarm and Warnings 2 4 Diagnostic Mode Chapter 3 Basic Isolator Operation ON ounn m A 921 9 3 1 Starting and Shutting Down the Isolator 9 3 1 1 Turning on the Isolator 9 3 1 2 Turning off the Isolator 9 3 2 Working in the Isolator 9 3 3 Working Ergonomics 10 3 4 UV Lamps Chapter 4 Maintenance 4 1 Scheduled Maintenance D 4 2 Glove Changing Procedure 12 4 3 Sleeve Changing Procedure 13 4 4 Sharps Container Removal Procedure 13 4 5 Maintenance Service Log APPENDIX Pharmacy Isolator ECCO UNE MANUAL REVISION HIS
23. ters cannot be reset either MENU ADMINSETTINGS gt RESET DEFAULT 2 2 4 10 Alarm Mute Duration To mute airfail alarm for a certain period The mute period can be set between 0 to 299 seconds the default value is 30 seconds MENU L ADMIN SETTINGS ALM MUTE DURATION XXX Ecco isocilean 2 3 Alarms and Warnings Isolator uses alarms to indicate that the condition inside the Isolator is not safe for the operator so check the LCD display to understand the cause of these alarms 2 4 Diagnostic Mode Diagnostic mode can be accessed by pressing the SET button The diagnostic mode allows the user to know the condition of the isolator or help the service engineer during maintenance and troubleshooting On Screen Explanation MODE Shows which mode is active NORMAL or MAINTENANCE VERSION Shows the version of the software eg CP103C V 1 0 TEMPERATURE Shows the temperature in the chamber ADC TEMP ADC for temperature in the chamber B H M Blower Hour Meter increase by the hour UV H M UV Hour Meter increase by the hour MONITOR Alarm monitor status PREPURGING Shows the pre purging warm up time value in minutes MUTE TIMER Shows the mute timer value in seconds DOWNFLOWMIN Downflow minimum value calibrated DOWNFLOWNOM Downflow nominal value
24. touched e UV light decontamination method may be used before and after working with vegetative organisms and viruses However it should not be the sole decontamination agent the use of chemical decontamination agent is still encouraged e Minimize the material inside the HPI s work area during the process of UV light decontamination A direct interaction with UV light can degenerate plastic or rubber based material and can cause other hazard e Make sure that the HPI window is in the fully closed position before activating the UV lamp Avoid direct contact with skin and eyes as UV light is classified as a probable human carcinogen e The UV lamp should be activated for around 60 minutes to work effectively Use the UV timer feature to easily control the period of decontamination UV timer is disabled by default Leaving the UV lamp on for over 60 minutes or even overnight is not recommended because it shortens the lifespan of the lamp The UV lamps used in Esco HPI have a lifespan of 2 000 hours e UV lamp should be cleaned of any dust and dirt weekly and changed annually to ensure its effectiveness e The use of UV lamp in HPI has been explicitly discouraged in all major international standards and recommendations isociean Chapter 4 Maintenance 4 1 Scheduled Maintenance Proper and timely maintenance is crucial for trouble free functioning of any device and your Esco HPI is no exception to this rule We strongly re
25. utor for specific warranty details Laboratory Fume Hoods 2 years limited Ductless Fume Hoods 4 years limited for Ascent Opti 6 years for Ascent Max Cleanroom Equipment 1 year limited Laboratory Ovens and Incubators 1 year limited CO Incubators 2 years limited Containment Pharma Products 2 years limited Ultralow Temperature Freezer 5 years limited 60 months on Compressor The warranty period starts two months from the date your equipment is shipped from Esco facility for international distributors This allows shipping time so the warranty will go into effect at approximately the same time the equipment is delivered to the user The warranty protection extends to any subsequent owner during the warranty period Distributors who stock Esco equipment are allowed an additional four months for delivery and installation providing the product is registered with Esco User can register product online at www escoglobal com warranty or complete the warranty registration form included with each product Policy updated on p January 2012 This limited warranty policy applies to products purchased on or after E January 2012 Ecco isociean Introduction 1 Products Covered Electrical Rating 220 240 V 50Hz 10 110 130 V AC 60Hz 10 220 240 V AC 60Hz 10 Model with 0 indicate that the isolator doesn t have sharps container Esco Isoclean Pharmacy Isolator 1 2 meters 4 feet 1 8 meters 6 feet
26. your eyes O Give your eyes frequent breaks Periodically look away from the work area and focus at a distant point o Keep your glasses clean e Arrange the items apparatus frequently used in your work in such a way that you can minimize the physical strain involved in handling them e Exercise regularly The HPI s noise emission has been tested and found to be in compliance with EN 12469 ISO 4871 and NSF ANSI 49 which is important to ensure health and comfort for the operator Ergonomics accessories available with Esco include e Armrest padding e Lab chair e Footrest Please contact your local distributor or Esco for more information 3 4 UV Lamps The UV light is a germicide virucide Even at the minimum acceptable irradiance in a HPI 40 uW cm US Department of Health and Human Services et al 2000 it would only take 12 5 minutes to reach 30 000 uW cm2 1 W 1 J sec which has been listed as germicidal for spore forming organism Unlike many other type of decontamination agent UV light doesn t leave any residue The decontamination action stops upon de energizing of the lamp However due to the short wavelength the UV light does not penetrate well Thus UV light can only be used to effectively disinfect the work area of an empty HPI For any container stored inside the HPI s work area the UV radiation will only disinfect the outer surface of the material leaving the inner surface and the content inside the material un
Download Pdf Manuals
Related Search
Related Contents
El Epson EMP-732 es el compañero de presentaciones profesional Philips 21PT4205 21" stereo TV Johnson Hardware 2555 User's Manual Capa Livro de Oftalmolagia.P65 - Clínica de lentes de contato Coral 静電気除去ファン 取扱説明書 取扱説明書 保証書付 BEDIENUNGSANLEITUNG FYSIC FM-800 SolarInfo Bank User Manual FRP Inspection Guide Copyright © All rights reserved.