1. controller log on operation Press the manual film A W buttons simultaneously release the buttons after a red indicator light flickers slowly on the back of the case 2 Press the button in the small holes on the back of the remote transmitter with lead of a pen or a small screw driver the indicator light is on now the remote controller logs on If by group control divide the lifters into groups first by grouping button the corresponding group logs on when the relative indicator light is on WwWhen erasing the old control codes please follow Press the manual film A W buttons simultaneously release the buttons after a red indicator light flickers quickly on the back of the case Press the A ME buttons simultaneously and the indicator light will be on now the old control codes are erased successfully Size of the lifter unit mm Figure 4 Accessories 1 manual control cable and button 1 set 2 power cable Ipc collective control setup operating steps 1 select COM port 2 grouping 3 Press the manual film A W buttons simultaneously release the buttons after a red indicator light flickers slowly on the back of the case 4 Click the relative 1temto set up the system The indicator light is on when you Succeed in Setup Installing illustration Cas figure 5 Slot size Installing steps 1 Decide the installation position on the desk surface and cut an opening based on t
2. Leada Technology Company China User s Manual for A3 Motorized LCD lift mechanism Brief introduction After intensive market research we develop and design a latest lifter for LCD monitor It features in light and artistic appearance easy and convenient installation efficient integrated control by single use or optional central control operator This product can be adjusted easily to avoid the direct light into human eye in accordance with the principle of ergonomics Features 1 motorized control and free running 2 free and reliable to use good anti shock performance 3 suitable for LCD monitors lt 15 4 automatic opening and closing of the d cor plate Index requirement 1 The body size of the 15 LCD monitors such as Samsung and Philips is less than 380X315X65mm 2 Power AC 220V 50Hz End use This product is suitable for high grade multi media system surveillance system as well as high grade multi media office etc Installation This product is a built in lifter for high grade office desk The LCD monitor is fixed onto the base inside cabinet when the lifter is kept level Troubleshooting Please call us for permission of customers self service on LCD monitor lifter A3 1 if the newly installed or used product breaks down Otherwise unauthorized service will render the warranty void Check the grounded protection to make sure of security in avoidance of electric shock accident A The tur
3. g or lowering LCD monitor 3 STOP Button 4 5 Button for LCD monitor inclination adjustment L 3 4 6 DHOOAAOS Figure 2 2 Power on to operate this product before you connect the wires to the sockets well x Methods of control By standardized manual film button Control option 1 By single use wireless remote control you can control a lifter individually 2 By group wireless remote control you can control five groups of lifters at most with remote control shaft 8 Collective control as figure 3 Groups Receiver antenna Indicator light Green ay E Al 3 Through serial communication port of computer you can make collective control on 16 groups of lifters by order Also you can make control by connecting optional central control system with the help of programmed transmission control protocol The control codes go as follow The data pattern of RS 232 remote controller Set up of RS 232 com port 1200 N 8 1 Namely 1200 baud parity none 8 data bits one stop bit 0 5 seconds Control Explanation codes Log on code n O0 f 1 f are the designated group numbers n 0 means complete control Stop code n 0 f 1 f means the designated group numbers n 0 means complete control Lifting code n 0 f 1 f means the designated group numbers n O means complete control Lowering code n 0 f 1 f means the designated group numbers n 0 means complete control Winstruction for remote
4. he accurately measured lifter specification After that cut a slot for the panel of the lifter 2 Make a test run before installing the lifter so as to make sure of safety Pull out the needed cables such as VGA wire power wire as well as manual control wire 3 Put the lifter into the cut opening carefully fasten the lifter well and connect the relevant cables For more details of our products please feel free to visit www leadachina com or contact us at leadachina hotmail com
5. ner cannot work at all Ll Check it to make sure that the power upper inlet and terminal is power on and the voltage is in normal condition If power fails check the power supply circuitry 2 If the power inlet andterminal work normally check to make sure that the connections of buttons are not loosened and the fuse available is on the power B The turner cannot move but weak shaking noises can be heard C The lifter cannot descend at all when it is on the upper running distance Please check if the running distance limitation switch is clamped Check the capacitors to see whether it is broken down and short circuited or not and its connection s loosened and broken or not If failure occurs shut off the power at once to avold burning the motor because of excessive heatness D The raising or lowering running can not be made but bigger noises fromthe lifter can be heard Ll Check if the transmission wheel or chain is stuck or the wheel is broken 2 Check if the transmission wheel engages with the transmission chain or not 3 Check if the axle case of the transmission chain is loosened or not 4 Check if the space between the transmission chain and wheel is too big Instructions 1 Illustration for the touch pad As figure 1 1 Touch pad 2 AC 220V power input 3 Socket for manual control input 4 5 multimedia signal input socket Figure 1 2 Explanation for touch pad as figure 2 1 2 Button for raisin
Download Pdf Manuals
Related Search
Related Contents
Aviom16/o-Y1User Guide C o m p a r a t i v e R o m a n c e L i n g u i s t i c s N e w s l e t t e r インテリジェントコントローラ設定ツール (形式:BA3B1CFG) 取扱説明書 CPI PDU USER MANUAL - Chatsworth Products Fox™ - Invacare Document 取扱説明書 - 660.4 KB ev/STARS/TWIN binary stellar-evolution code 8080/8085 floating-point arithmetic library user`s manual M32150 datasheet Copyright © All rights reserved.