Home
Leica Viva TPS Getting Started Guide
Contents
1. Version 3 0 English Leica Viva TPS Getting Started Guide when it has to be right Geosystems Viva TPS Introduction 2 Introduction To use the products in a permitted manner please refer to the detailed safety instructions in the Leica CS10 CS15 User Manual Leica GS10 GS15 User Manual Leica TS11 TS15 User Manual and Leica TPS1200 User Manual S For detailed descriptions of all functions and settings of the product and applications please refer to the Leica Viva Series Technical Reference Manual Purpose of this This Getting Started Guide is intended as a quick field reference manual for immedi manual ately getting started with your Leica Viva Series equipment The manual explains what you can find in your container how everything fits together and how to get started on the basic applications Quick references une Topic Refer to to specific topics What s in my container Chapter 1 1 How does the equipment all fit together Chapter 1 2 What is this first screen see when turn on my instrument Chapter 2 1 How do I get to the Main Menu Chapter 2 1 How do I select things and move around the screens Chapter 2 2 What are wizards Chapter 2 2 Topic Refer to How do get started with jobs and codelists Chapter 3 How to use the applications Chapter 4 m world myWorld Leica Geosystems https myworld leica geosystems com offers a Leica Geosystems
2. To configure the camera if available Main Menu function Description User e To format the memory device e To upload files relevant for the instrument functionality for example firmware files language files and licence keys To transfer data between the memory device and a Standard and simple FTP server To view files on the memory device or the internal memory To access all configuration parameters individualising the system and the working style For TS11 TS15 To check and adjust the compensator index error and line of sight error Viva TPS SmartWorx Viva and Principles 39 Viva TPS SmartWorx Viva and Principles 40 2 1 4 Leica Favourites Description Frequently used settings can be accessed and changed quickly through the Leica TPS Favourites and Leica GPS Favourites screens The change is applied immediately and the workflow is not interrupted The screens display selectable icons for quick check functions or for available settings to change to Access For TPS e Tap the target aiming icon or select _ gt For GPS e Tap the position status icon or select _ gt Leica TPS Leica TPS Favourites Favourites a A amp ui _ Measu wre an Surface Continuous meas on Change face 4 5 HW 6 2 Powersearch Right PowerSearch Left Red laser on OK To apply the selected setting or to Auto aiming Target lock on Page access the selected function Hz 179 59 59 V
3. j Windows CE k Favourites I ESC m Arrow keys OK n ENTER o Fn p ON OFF q Home r Function keys F1 F6 SmartWors StartUp Wizard Welcome to Smartiors Viva feica Geosystems B night O Don t show this panel during StartUp e Turn on your GS GNSS or TPS instrument e Turn on your CS field controller and start SmartWorx Viva K gt For information about wizards refer to Wizards 2 1 1 Screen Screen CS15 field controller 7 6 8 Ota in b PETET e f aa Instrument ao User aC Settings amp status a Software settings Connections Screen amp audio g h Cig es Fa bbe Ogg c OK SYS13_028 Elements Element Description Icons Title Screen area Message line Softkeys ESC Fn Entry mode Time Time The current local time is shown Title Name of the screen is shown Screen area The working area of the screen Message line Messages are shown for 10 s Viva TPS SmartWorx Viva and Principles 29 Viva TPS SmartWorx Viva and Principles 30 Element Description Icons Shows status information of the instrument Refer to 2 1 2 Icons Can be used with touch screen ESC Entry mode Can be used with touch screen Same functionality as the fixed key ESC The last operation will be undone The caps mode for upper case letters is active The caps mode is activated and deactivated by pressing the CAPS key Fn
4. or the instrument face or Il icon Displays the instruments that are currently configured and active When more than one instrument Is config ured the instrument at the front of the icon is the active instrument Icon Description Camera Select this icon to begin the camera function Data management o oO md ia Select this icon to open the data management pages for Points Lines or Areas If there are open lines or areas a symbol will appear in the icon Memory storage Displays the status of the internal memory or data storage device Battery Displays the status and location of the battery GNSS specific icons ian Description Position status Oo Displays the status of the current position As soon as this icon becomes visible the instrument is in a stage where practical operation can commence Viva TPS SmartWorx Viva and Principles 35 Viva TPS SmartWorx Viva and Principles 36 Icon Description Number of visible satel Displays the number of theoretically visible satellites lites above the configured cut off angle according to the current almanac V w Contributing satellites Displays the number of satellites that are contributing to the currently computed position solution ey K The number of contributing satellites can differ from the number of visible satellites This differ ence can be because satellites cannot be viewed or b
5. 0000r w ui Fn Quit To exit the screen To change to one of the displayed settings or access a quick check function do one of the following e Tap on the icon on the touch screen e Highlight a field and press gt lt Highlight a field and press Ose e Highlight a field and press OK e Press the number next to the setting or function Viva TPS SmartWorx Viva and Principles 41 Viva TPS SmartWorx Viva and Principles 42 Leica GPS Favourites Leica GPS Favourites I 2 a Current E aN Satelite tracking ATK data link status 4 5 6 Rg ro in Zo RIK settings RTK load profiie Server mountpoint OK 7 a ro av To apply the selected setting or to access the selected function To exit the screen To change to one of the displayed settings or access a quick check function do one of the following e Tap on the icon on the touch screen e Highlight a field and press Z gt Gp e Highlight a field and press gew e Highlight a field and press OK e Press the number next to the setting or function 2 2 Operating Principles Accessing a menu Description Illustration option There are three ways to access a menu option 1 Using the touchscreen functionality Tap on the menu item using the stylus provided EJ View amp edit data EJ Job properties E Choose working job 2 Using the up and down navigation arrows EJ Choose control job or press the OK 8 button or the ENT
6. Switches between the first and second level of function keys Commands can be ran using F1 F6 keys only applicable for CS15 field controller The commands assigned to the softkeys are screen dependent Can be used directly with touch screen Common softkeys The softkeys following are used commonly in the Leica SmartWorx Viva software across all applications Function Key Description F1 To select the highlighted option and to continue with the subsequent screen To change to another page on the current screen Fn F3 To open the Leica SmartWorx Viva online help To move the focus to the top of the list shown in the current screen To move the focus to the bottom of the list shown in the current screen Fn F6 To exit the current application and return to the screen from where the application was accessed Viva TPS SmartWorx Viva and Principles 31 Viva TPS SmartWorx Viva and Principles 32 Key combinations Key Function Hold Fn while pressing 1 Increase the screen bright ness Hold Fn while pressing 3 Increase the volume for acoustic warning signals beeps and keypresses on the CS field controller Hold Fn while pressing 4 Decrease the screen bright ness Hold Fn while pressing 6 Decrease the volume for acoustic warning signals beeps and keypresses on the CS field controller Hold Fn while pressing 0 If keyboard illumination is already off Turn
7. achieve the best performance from the TCPS28 mount it ina vertical position on the tripod leg approximately 30 cm from the top If the adapter is no longer able to retain its angle position the adjustment bolt at the hinge can be tightened slightly 1 7 Fixing the CS to a Holder and Pole Components of the The GHT62 holder consists of some components as shown in the diagram GHT62 holder GHT63 clamp a Plastic sleeve b Pole clamp c Clamp bolt GHT62 holder d Locking pin e Top clip f Mounting plate extendable g Bottom clip h Tightening screw i Mounting arm 1 tsa Viva TPS Equipment 23 Viva TPS Equipment 24 Fixing the CS field controller and GHT62 to a pole step by step Step Description If you use the CS15 field controller extend the mounting plate of the holder first For an aluminium pole fit the plastic sleeve to the pole clamp Insert the pole into the clamp hole Attach the holder to the clamp using the clamp bolt Adjust the angle and the height of the holder on the pole to a comfortable position Tighten the clamp with the clamp bolt Before the CS field controller is placed onto the mounting plate ensure that the locking pin is put into the unlocked position To unlock the locking pin push the locking pin to the left TS_055 Hold the CS field controller above the holder and lower the end
8. by using the Import ASCII data function ality E At least one ASCII file with any file extension must be stored in the DATA directory of the internal memory or data storage device Import ASCII data Starting the ASCII Importer step by step t Go to Work e From the Main Menu select Jobs amp Data Survey amp stake pts Stet base Station e Inthe Jobs amp Data menu select Import data then Import ASCII data and access the Import Ej View amp edit data ASCII Data screen EJ Job properties Ej Choose working job a Choose control job Sf 1 Import ASCII data Viva TPS Jobs amp Data 57 Viva TPS Jobs amp Data Data type to import ASCII data Data type to import ASCII data 58 e Select the data storage device the data type ASCII data the file to be imported the working job into which the data has to be imported and define whether header lines have to be considered e Enter the Configuration screen Config Configuring the ASCII Importer e Select the Delimiter e Define the position for Point ID Easting Northing Height and Code if applicable e Confirm the configuration settings and return to the Import ASCII Data screen OK e Enter the Define Ht Type amp Easting Import screen Fn Hts Viva TPS Jobs amp Data Define Ht Type amp Easting Import Import as Orthometric From pore Data j From 4 Import of data completed ram 1000 points
9. first job e Press Page to change to the Codelist page General Cadelist CAD files Coord system TPS scale 4 gt mone a Tap on the selectable list to open the Codelists screen e Press New to create a codelist Edit Delete More e Type in a Name Description and Creator are optional Tre e Press Codes to open the Codes screen Viva TPS Jobs amp Data 53 Viva TPS Jobs amp Data rib i Ed it Del ete More 54 Creating a code e Press New to create a code e Type in a Code EL and a Description Light Pole select the Code group Electric the Code type Point and the Linework None and create an attribute Diameter e Press Store to save the new code The Code group has to be created first before it can be selected e Press OK to return to the New Codelist screen New Codelist Storing the codelist eae e Press Store to save your codelist You will auto oe corel matically return to the Codelists screen e Press OK to return to Job Properties Codelist page e Press Store to save your job and to return to the Main Menu OK Viva TPS Jobs amp Data 55 Viva TPS Jobs amp Data 56 gt You have created your first codelist with a i am Goto Work f code and a code group and attached it to Satta smion Sept ego your current working job 3 3 Importing ASCII Data into a Job Objective Importing point objects into the working job
10. wide range of services Information and training material With direct access to myWorld you are able to access all relevant services whenever it is convenient for you 24 hours a day 7 days per week This increases your effi ciency and keeps you and your equipment instantly updated with the latest informa tion from Leica Geosystems Service Description myProducts Simply add all Leica Geosystems products that you and your company own View detailed information on your products buy additional options or Customer Care Packages CCPs update your products with the latest software and keep up to date with the latest documentation Viva TPS Introduction 3 Viva TPS Introduction Service Description myService mySupport myTraining View the service history of your products in Leica Geosystems Service Centers and detailed information on the services performed on your products For your products that are currently in Leica Geosystems Service Centers view the current service status and the expected end date of service Create new support requests for your products that will be answered by your local Leica Geosystems Support Team View the complete history of your Support and view detailed information on each request in case you want to refer to previous support requests Enhance your product knowledge with the Leica Geosystems Campus Information Knowledge Training Study the latest online training materia
11. ER L button 3 Using the numbered keypad Select the 3 9 3 number that corresponds to the menu item e go For example press 1 from the Jobs amp Data P x menu to access the New job screen n A 3 Viva TPS SmartWorx Viva and Principles 43 Viva TPS SmartWorx Viva and Principles 44 Accessing a selectable list Description Illustration A downward arrow beside a field indicates there are more choices available in a selectable list A box and a downward arrow beside a field indi cates that there are more choices and function ality available in a separate screen To access the list or screen use the touchscreen functionality to tap on the icon or move the focus to the field and press the ENTER gt button Accessing a page within a screen Description Illustration To access another page within a screen either e Tap on the page tab for the page to be displayed or e Select Page until the page is displayed Exiting a screen without making a change To exit a screen without making a change either Description Illustration e Tap on the return icon or e Press the ESC s gt button Wizards The wizards following are available to make your daily work easier Each of them lead you through a series of steps performing tasks in a specific sequence For detailed descriptions of the wizards please refer to the Leica Viva Series Technical Reference Ma
12. Now you have completed your setup with SmartStation Setting up with Job fixpoint job Starting Setup SmartPole step by e Inthe Go to Work menu select Setup step e Choose one of the following setup methods HEGEL and select OK Station is not known A Measure to 2 or more Multiple backsights A known target points to f bf Spas sin ne Resection JER Coord 5 amp onentation Known backsight These methods are the only methods applicable for a setup with SmartPole e The process for Setup method Resection is shown here Viva TPS Applications 65 Viva TPS Applications Enter Station Information eine Somer a TE ee es ee fixpoint job L OO0O0NOO0000 Meas Dist Store 66 Enter station information e Station ID Enter a name for the station e Instrument height Enter the height of the instrument station e Ifall your control points will come from GPS leave Use control job for the target points unselected e OK to access the measure target points screens Measuring the target points e Target height Enter your prism height When moving to GPS Survey the correct vertical offset will be applied so you automatically have the correct antenna height e GPS to first enter GPS Survey before returning to this screen e Meas to start the point measurement e Stop to end the point measurement e Store to store the point information and auto matically re
13. a TPS Applications 75 Viva TPS Applications 76 Stakeout Filter e Set View Points to stake e Press OK three times to return to the Stakeout screen Staking out your first point object e Navigate to the point and press Dist Pointooi ia e While measuring the point you still can see the E R differences between the coordinates of the design point and the coordinates of the point Target height a you measured Hz 100s Meas Dist K The continuous measurement mode can be used for staking out e The next point in the list to be staked out is displayed after the point was measured and stored by pressing Meas CS You finished staking out your first point 4 4 Reference Line Objective Measuring or staking point objects fire hydrants light poles etc relative to a refer ence line Measuring point Job Customer 1 Starting Measure to ref line objects relative to a reference line step by step e In the Go to Work menu select Survey and access Survey menu Cs Staking a reference line can also be O coco accessed under Go to Work Stakeout Roads Os Switch t to Base menu Stake to ref line e Select Measure to ref line and continue OK 2 1 Measure to ref line IFJ Reference plane ce Volume calculations 4 Determine coord system CG QuickGrid Eg uk neeesa eni D pin 3 Viva TPS Applications 77 Viva TPS Applications Reference Line Startup Measure points relative to a
14. bs amp Data 50 3 Jobs amp Data 3 1 Creating a New Job Creating ajobstep General steps to create your first Job in SmartWorx Viva by step Creating your first job Jobs amp Data e From the Main Menu select Jobs amp Data and ainda marsemere press OK ka Re User Software settings Sora Bi dio e Select New job from the Jobs amp Data menu and press OK Ej View amp edit data E Job properties Ej Choose working job E Choose control job O import data 7 e Enter a name for the Job e Use Page to toggle between the pages to set the proper Codelist CAD files Coord system TPS scale and Averaging e Press Store to save the job gt You have finished creating your first job t Goto Work which is selected as current working job Sut base amtoa T pataan You will automatically return to the Main Menu and are ready to start the next activity Viva TPS Jobs amp Data 51 Viva TPS Jobs amp Data 52 3 2 Creating a Codelist Creating a codelist Generals steps to create your first codelist in SmartWorx Viva step by step Creating your first codelist Go to Work Jobs amp Data From the Main Menu select Jobs amp Data and L Sat base acon ey ed Vectacoot press OK e Select Job properties from the Jobs amp Data menu and press OK Ej View amp edit data 3 J0b properties E Choose working job E Choose control job O import data te stile na copy data Job Properties My
15. defined line while constantly wewing your position relative to the line 78 Define the Reference line task e Set Reference line task Measure to line and continue OK Choose Control Job e Select the job which contains the points used to define the reference line e Press OK to access Reference Line To Use screen Define the reference line to be used e Set Create line using 2 points e Select a Start point e Select an End point e Press OK to access Measure Points screen Measure Points Measure the point object relative to the refer Ref Line Map ence line Point ID P Antenna height 2 000 e Inthe Measure Points screen press Meas to A offset 0 003m measure the point line 0 005m ar gt You have finished measuring your first A ht start of line 1 995m r p Elevation AEF FAIM point object relative to a reference line A end onf line ji SONOS en Viva TPS Applications 79 Viva TPS Working with Memory Devices 80 Appendix A A 1 General Working with Memory Devices Formatting a Memory Device Formatting a memory device before storing data on it is required if the device is new or if all data on the device must be deleted By activating the format command all data will be lost Make sure that all important data on the device has been backed up before formatting If formatting the internal memory make sure that all important data is first transferred to
16. ecause the observations to these satellites are considered too noisy to be used Real time device Displays the real time device configured to be used ae af hes O Real time status Displays the status of the real time device configured to be used f F 9 2 1 3 Main Menu Main Menu a Go to Work a Survey amp stake pts Start base station gt Instrument aC Settings amp status C nnechons Viva TPS SmartWorx Viva and Principles Jobs amp Data Point management Import amp export User D Software settings Screen amp audio OK To select the highlighted option and to continue with the subsequent screen Fn Mode To switch between GPS and TPS modes Fn Exit To close Leica SmartWorx Viva soft ware 37 Viva TPS SmartWorx Viva and Principles 38 Main Menu f Main Menu function Description functions Go to Work e To select and start an application Jobs amp Data e To manage jobs data codelists GNSS antennas reflec tors and coordinate systems To export data from a job on the instrument to a file on the memory device in a customised ASCII format or in DXF format To import ASCII GSI or DXF data from a file on the memory device to a job on the instrument To copy points between jobs Instrument e To access all configuration parameters related to a survey the instrument and the interfaces e To view the various instrument status screens e For TS11 TS15
17. ed to a point line or area Press Prev to link the screenshot with the last stored point and save it Press Any to link the screenshot with any point line or area of the current working job and save it Press No to save the screenshot in the current working Job without linking it to a point line or area Cs After the screenshot has been stored you automatically return to the screen where the screenshot has been taken from 2 3 Connecting TPS instrument and CS field controller Connecting TPS instrument and CS field controller setup step by step Fix either a hand strap to your CS field controller or fix your CS field controller to a holder and pole Step Description Set up your TPS instrument Refer to 1 2 Setting Up the TPS Instrument Turn on your TPS instrument and your CS field controller gt Ensure that your TPS instrument is ready for remote control The RCS mode is only available for the CS15 field controller while the datalogger mode is available for all CS field controllers Start the SmartWorx Viva software Refer to 2 1 SmartWorx Viva Select Main Menu Instrument Instrument connections TPS connection wizard to start the TPS connection wizard For detailed descriptions please refer to the Viva Series Technical Reference Manual Follow the TPS connection wizard and connect your TPS instrument to your CS field controller Viva TPS SmartWorx Viva and Principles 49 Viva TPS Jo
18. es From the Main Menu select User Tools amp other utilities Load firmware amp Apps Object to transfer Select the type of object to upload From Select the data storage device where the object is located App Firmware Language Select the file name of the object Select OK to upload the object onto the instru ment 87 Viva TPS Uploading System Files 88 e The upload process can take some time A message will appear when the upload is rom Langi System language upload was complete successful Do you wish to use this language Appendix C Leica Geo Office Description Leica Geo Office LGO is an office software consisting of a suite of standard and extended programs for the viewing exchange and management of data Jobs codelists and other related files can be transferred from the instrument or data storage device to LGO for post processing In LGO the Data Exchange Manager enables data to be transferred between an instrument and a computer The Import Raw Data function in LGO imports the data from the computer or data storage device into an LGO project Viva TPS Leica Geo Office 89 Viva TPS Leica Geo Office 90 Transferring files Step to LGO step by step If data is located on a data storage device insert the device into the appropriate slot or port of the computer Go to step 7 If data is stored on the CS10 CS15 instrument connect the instru ment to the computer using t
19. et 4 over the ground point Adjust the tripod legs to level the circular level 7 By using the electronic level turn the tribrach footscrews 6 to level the instrument precisely Centre the instrument precisely over the ground point 4 by shifting the tribrach on the tripod plate 2 8 Repeat steps 6 and 7 until the required accuracy is achieved 1 3 Setting Up SmartStation SmartStation setup step by step Step Description l Place the adapter for the GS15 GS12 instrument onto the instrument by simultaneously pressing and holding in the four push buttons Viva TPS Equipment 15 Viva TPS Equipment 16 Step Description CS _ Ensure that the interface connection on the underside of the adapter is on the same side as the Communication side cover TS_060 Description Place the GS15 GS12 instrument onto the adapter by simultaneously pressing and holding in the two press clips Viva TPS Equipment 17 Viva TPS Equipment 1 4 Setting Up SmartPole SmartPole setup using GS15 ona TS15 instrument 18 GS15 instrument RTK slot in device GRZ122 360 prism GLS30 pole with snap lock positions CS field controller GHT62 holder and GHT63 clamp RH15 RadioHandle Communication side cover integrated TS15 instrument Tripod SmartPole setup using GS12 ona TS15 instrument Viva TPS Equipment a b c d e f g h
20. he docking station or a USB cable Copy the data to the computer using Microsoft ActiveSync or Windows Mobile Device Centre Go to step 7 If data is located on the TPS instrument connect the instrument to the computer using a USB cable Bluetooth connection or an RS232 serial cable Go to step 2 Description Select Tools Data Exchange Manager to open the Data Exchange Manager window 3 Right click in the Data Exchange Manager window and select Settings e For a USB connection ensure that the USB port settings are config ured for the instrument type being connected e Fora Bluetooth or RS232 serial cable connection ensure the instru ment interface settings and the computer COM settings are config ured correctly Select OK to close the Setting window Step Description In the folder directory on the left of the Data Exchange Manager window open the Serial Ports or USB COM node to which the instrument is connected Highlight the object to transfer In the folder directory on the right open the My Computer Files folder location Select a folder on the computer hard drive where the object can be transferred to and saved Drag and drop or copy and paste the object from the directory on the left side to the selected folder on the right side All object specific files will be copied to the selected folder on the computer hard drive To import the files into LGO select Import Raw Data or select
21. i GS12 instrument GRZ122 360 prism GLS12 cm GLS12F ft pole with snap lock positions CS field controller GHT62 holder and GHT63 clamp RH15 RadioHandle Communication side cover integrated TS15 instrument Tripod 19 Viva TPS Equipment 20 1 5 Setting up for Remote Control with the RadioHandle TPS CS setup for remote control with RadioHandle a D a 360 prism d 0 b Prism pole c CS field controller d GHT62 holder and GHT63 clamp e RH15 RadioHandle f Communication side cover g TPS instrument h Tripod TS_063 1 6 Setting up for Remote Control with the TCPS28 TPS CS setup for remote control with TCPS28 a 360 prism b Prism pole c CS field controller d GHT62 holder and GHT63 clamp e TPS instrument f Tripod g TCPS28 h External battery i Y cable TS_062 Viva TPS Equipment 21 Viva TPS Equipment 22 Mount base radio Step to tripod step by step Description The GHT43 tripod adapter is used to mount the TCPS28 to all Leica standard tripods and to optimise the radio transmission performance Attach the TCPS28 to the adapter and then attach the adapter to the tripod leg Adjust the angle of TCPS28 until it is vertical Adjust the location of the adapter on the tripod leg so that there are no metallic objects in the horizontal plane around the antenna CS Metallic objects near the antenna disturb radio transmissions gt To
22. ice is completed the system returns to the Main Menu A 2 Directory Structure of the Memory Device Directory structure CODE I CONFIG RTK_PROFILE I USER MANAGEMENT CONVERT Viva TPS Working with Memory Devices Codelists various files Working style files xfg RTK profile files rpr Administration settings files usm Format files frt ASCII txt DXF dxf LandXML xml Terramodel xml Carlson cl and Shape files shp shx and dbf and all other shape file components for import export to from job Section files for Carlson sct and ASCII report files for Terramodel txt for import to Job Report sheets created from applications CSCS field files csc 83 Viva TPS Working with Memory Devices I GEOID I RINEX I XML I DBX O E a MAP I IMAGES ee DOWNLOAD I GPS I GSI 84 Geoid field files gem RINEX files Alignment Editor Alignments xml DTM jobs various files Coordinate system file Trfset dat Job files for System 1200 Job files various files Jobs are stored in a folder per job Map related files for example mpl stored in a subfolder per job Image files jpg stored in a subfolder per job Various files downloaded by the Field to Office application Antenna file List ant GSM Modem sta
23. imported To jol records skipped al Do you wish to impart any Head more data Define height type and Easting import Define how heights Orthometric or Ellip soidal and how the Easting is imported Confirm the configuration settings and return to the Import ASCII Data screen OK Importing the ASCII data Import the ASCII data to the working job OK After importing the ASCII data to the working job complete the import No and return to the Main Menu or import another ASCII data Yes 59 Viva TPS Jobs amp Data 60 CS You have completed importing ASCII data into your current working job G Applications Getting started Viva TPS Applications OK New Edit Delete Data SD card Check that the correct working style see User Working style wizard is being used Check that the correct working job see Jobs amp Data Choose working job is being used 61 Viva TPS Applications 62 4 1 Setup Objective Determine the station coordinates and the orientation of your TPS instrument using TPS measurements and or GNSS measurements Setting up with SmartStation step by step Starting Setup e In the Go to Work menu select Setup e Choose one of the following setup methods s ll and select OK Station is known Measure to 1 known Set orientation target point to set 4 Known backsight Multiple backsights Transfer height These are the only methods app
24. l or download training material on your products Keep up to date with the latest News on your products and register for Seminars or Courses in your country Table of Contents In this manual Chapter Page 1 Equipment 7 1 1 Container Contents 7 1 2 Setting Up the TPS Instrument 13 1 3 Setting Up SmartStation 15 1 4 Setting Up SmartPole 18 1 5 Setting up for Remote Control with the RadioHandle 20 1 6 Setting up for Remote Control with the TCPS28 21 1 7 Fixing the CS to a Holder and Pole 23 2 SmartWorx Viva and Principles 27 2 1 SmartWorx Viva 27 2 1 1 Screen 29 2 1 2 Icons 33 2 1 3 Main Menu 37 2 1 4 Leica Favourites 40 2 2 Operating Principles 43 2 3 Connecting TPS instrument and CS field controller 49 Viva TPS Table of Contents 5 Viva TPS Table of Contents 3 Jobs amp Data 50 3 1 Creating a New Job 50 3 2 Creating a Codelist 52 3 3 Importing ASCII Data into a Job 57 4 Applications 61 4 1 Setup 62 4 2 Survey 69 4 3 Stakeout 72 4 4 Reference Line 77 Appendix A Working with Memory Devices 80 A 1 Formatting a Memory Device 80 A 2 Directory Structure of the Memory Device 83 Appendix B Uploading System Files 86 Appendix C Leica Geo Office 89 1 1 1 Container for instrument and delivered accessories part 1 of 2 Viva TPS Equipment Equipment Container Contents h i j GHMOO7 Instrument height meter and GHT196 tribrach bracket for height mete
25. licable for a setup with SmartStation Set Station Point CASEN Fa ae 14 40 Near A No coordinate system selected Local to enter local coordinates for the setup point CrdSys to select an existing coordinate syste Viva TPS Applications Setting the station point e Station point from Select GPS SmartStation e Instrument height Enter the height of the instrument station Ensure that the correct antenna type is set This will ensure the vertical offset between the TPS and GS12 GS15 instrument is accounted for e OK to access the GPS Survey screen Measuring the station point e Meas to start the point measurement e Stop to end the point measurement e Store to store the point information Selecting a coordinate system If a coordinate system has not been selected e Local to access One Pt OneStep OR e CrdSys to access Coordinate Systems to select an existing coordinate system On this screen the creating and editing of coordinate systems Is also available 63 Viva TPS Applications 64 e CoordSys Name Enter a name for the local coordinate system e Enter local coordinates for the setup point e OK to set the coordinate system Setting the station orientation e Backsight ID Select the relevant point id for the backsight point e Dist to measure the point e Set to set the station orientation and return to the Main Menu 3 357 356s EELE Set Dist GPS More Page gt
26. martPole SmartStation and delivered accessories part 1 of 2 Viva TPS Equipment GS12 instrument GEB211 GEB212 battery GRZ4 GRZ122 prism GRZ101 mini prism GAD103 adapter for GRZ101 mini prism GAD31 adapter Spare stylus Allen key GHT63 clamp CS10 field controller GHT62 holder SD card CompactFlash card and covers GHT62 holder extended CS15 field controller 11 Viva TPS Equipment Container for GS12 SmartPole SmartStation and delivered accessories part 2 of 2 SYS _034 12 RH15 RadioHandle GMP101 mini prism Field controller GDC221 car adapter for CS field controller Mini prism spike GAD104 adapter for GS12 instrument Manuals amp DVD Cables 1 2 Setting Up the TPS Instrument TPS setup step by step Description Shield the instrument from direct sunlight and avoid uneven temperatures around the instrument Extend the tripod legs to allow for a comfortable working posture Position the tripod over the marked ground point centring it as well as possible Viva TPS Equipment 13 Viva TPS Equipment 14 Step Description 2 Fasten the tribrach and instrument onto the tripod Turn on the instrument by pressing Select Main Menu lnstru ment TPS settings Level bubble amp compensator to activate the laser plummet and electronic level Move the tripod legs 1 and use the tribrach footscrews 6 to centre the plumm
27. nu select Stakeout and access Stakeout Viva TPS Applications Choose Control Job Choose Control Job e Select the job which contains your point objects to be staked out e Press OK to enter the Stakeout screen Configuring Stakeout e Press Fn Config to access the Configuration screen im HET ibea Gia 14S Config Quit e Configure the following settings e General page Quality control page and Report sheet page Leave all settings unchanged e Heights page Check Offset height of all points being staked and set Height offset to 0 000 m 73 Viva TPS Applications rset C Switch to bulls eye when 0 5m from target a ae when ee Meas Dist Store Help Finches End rig Filter Quit 74 e Graphics page Set Navigate direction Following arrow and Navigate using In out left right Press OK to return to the Stakeout screen Setting up filters Tap on the box with the downward arrow right of the Point ID to open the Data screen All points stored in the control job are shown Press Fn Filter to access Sorts amp Filters screen Sorts amp Filters e Set Filter by Point code e Press Codes to access Point Code Filter screen e Press None to set all codes to No e Highlight code EL and press Use to activate it e Press OK to return to the Sorts amp Filters screen e Press Stake to access Stakeout Filter screen lendes Stake Viv
28. nual Wizard Description SmartWorx StartUp Wizard Define the behaviour of your instrument for a general start up RTK rover wizard Set up your real time rover TPS connection wizard Connect your CS field controller with your TPS instrument Internet wizard Connect your CS field controller with the Internet Viva TPS SmartWorx Viva and Principles 45 Viva TPS SmartWorx Viva and Principles 46 Wizard Description CS connection wizard Connect your CS field controller with your TS11 TS15 instrument Working style wizard Configure the parameters and functions of Smart Worx Viva so that It suits to your preferred method of working and save the settings in a working style Check amp Adjust Wizard For TS11 TS15 Check and adjust the instrument in the field by running through specific measurement procedures Taking an Description image using the instruments l Tap the camera icon SJ in the icon bar to access the Capture Image camera with Camera screen gt Fora CGS field controller which is configured to use a T 11 TS15 instrument with a wide angle camera the Capture Image with Camera screen has two pages TS wide angle and CS camera Select which camera to use by clicking the corresponding page or using Page to toggle between both pages 2 Aim the camera to the desired target Description Check the view at the display Press OK or click Cpture to take the picture gt Cp
29. of the CS field controller into the mounting plate Viva TPS Equipment Step Description Apply slight pressure in a downward direction and then lower the top part of the CS field controller until the unit is clicked into the holder The guides of the mounting plate aid in this action After the CS field controller is placed onto the mounting plate ensure that the locking pin is put into the locked position To lock the locking pin push the locking pin to the right gt TS_054 25 Viva TPS Equipment 26 Detaching the CS from a pole step by step Unlock the locking pin by pushing the locking pin to the left of the mounting plate Description Place palm over the top of the CS until fingers grip the bar of the holder underneath Push from the top of the CS toward the bar of the holder 4 While in this position lift the top of the CS from the holder SmartWorx Viva and Principles 2 1 SmartWorx Viva Keyboard a TS11 TS15 b C d e f g h i j k l m n F2 F3 F4 F5 F6 o P q r TS_087 Viva TPS SmartWorx Viva and Principles 27 Viva TPS SmartWorx Viva and Principles Start using Smart Worx Viva a b c d e f g h i Function keys F7 F9 key Brightness Alphanumeric keys Backspace Volume Function keys F10 F12 Keyboard illumination Screenshot 28
30. pplications 69 Viva TPS Applications 70 Selecting the code menor a Highlight Code and select the code EL for Elec Tie A tric Light pole To select the code EL toggle to the code or type in the letters to open the drop down list and search for the code CS Enter the search text in the same case as the code for example capitals Measuring the point object e When the code is selected press Meas to measure the point object e After the measurement has been stopped the Enter Mandatory Attribute screen will appear since the attribute Diameter is mandatory and is currently blank e Enter a diameter of 300 mm and press OK to store the point You have finished measuring your first point object Once the point is stored then the code and attribute value that was stored are displayed Viva TPS Applications 71 Viva TPS Applications 4 3 Objective Staking out point objects step by step 72 Stakeout Staking out point objects To make your life easier you will define a filter before Staking out the point object The filter will be defined the way that only points with a certain code and those points which have not yet been staked will be available to be staked out gt To accelerate the working example skip the steps regarding the filters and proceed directly with staking out the point object Job Customer 1 Starting Stakeout Be eo Jobs amp Data Inetmiment User e Inthe Goto Work me
31. r GEB221 battery Data transfer cable GFZ3 or GOK6 diagonal eyepiece Counterweight for diagonal eyepiece Instrument with tribrach and standard handle or RadioHandle Protective cover for instrument sunshade for objective lens and cleaning cloth Allen key GEB221 battery GMP101 mini prism Viva TPS Equipment Container for instrument and delivered accessories part 2 of 2 Pocket knife Spare stylus Manuals 2 x SD cards and covers Tip for mini prism GKL211 battery charger Car adapter power plug for battery charger stored under battery charger Container for GS15 SmartPole SmartStation and delivered accessories part 1 of 2 Viva TPS Equipment SYS_019 GS15 instrument GEB211 GEB212 battery GRZ4 GRZ122 prism Radio antennas GRZ101 mini prism and GAD103 adapter Spare stylus Allen key GAD31 adapter CS10 field controller GHT62 holder GHT62 holder extended CS15 field controller SD card CompactFlash card and covers Viva TPS Equipment Container for GS15 SmartPole SmartStation and delivered accessories part 2 of 2 a b c d e f g h i j 10 RH15 RadioHandle Instrument carry handle GHT63 clamp Cables GDC221 car adapter for CS field controller GAD108 arm GAD110 adapter for GS15 instrument Manuals amp DVD GMP101 mini prism Mini prism spike Container for GS12 S
32. s on keyboard illumination If keyboard illumination is already on Turns off keyboard illumination Hold Fn while pressing Take a screenshot of the current SmartWorx Viva screen Refer to Taking a screenshot 2 1 2 Icons Description The screen icons display the status information of the instrument ae The icons provide information related to basic instrument functions The icons that appear depend upon which instrument is used and the current instrument configu ration Icon bar TPS Mode a b c dee f g h i oo doo d o oo en LETERE Er SYS13_026 es a Automatic aiming f Camera b Prism g Line area auto points c Measure mode h Memory storage SD card USB d Instrument face I amp IIl Compensator stick internal memory level i Battery level field controller instru e Current active instrument ment Viva TPS SmartWorx Viva and Principles 33 Viva TPS SmartWorx Viva and Principles Icons 34 Icon Automatic aiming DOK Prism QEA Description Displays the current automatic aiming PowerSearch or prism search lock settings Displays the selected prism Measure mode 6 gt _ _ eI Displays the selected measurement mode The red laser icon will display when the red laser is active Compensator level and instrument face or Il Sr T Current active instru ment L Xe 8 2 ae da dT 28 Displays the compensator off or out of range icons
33. the a icon from the toolbar Viva TPS Leica Geo Office 91 Viva TPS Leica Geo Office 92 Description In the Import Raw Data window select the type of data to be imported in the Files of type drop down list Values are e SmartWorx raw data e GSI Observations e GSI Points only e Database points DBX GeoDB e LandXML E When importing GSI data click the Settings button to define addi tional import settings for how the TPS raw data will be imported to a project 10 Browse through the folder directory and select the file or folder to import The file or folder can be on the computer hard drive or on the inserted data storage device Select Import to proceed to the Assign window Step Description In the Assign window before assigning the data to a project the following functionality is available Select the TPS tab to preview the raw TPS data On this page it is possible to select or deselect which data is assigned to the project Select the GPS tab to preview the raw GPS data On this page it is possible to select or deselect which data is assigned to the project Select the Settings tab to modify the assign settings The settings available depend on the type of data to be imported Select the Backup button to save if desired the raw data from a data storage device to the computer hard drive Select a directory from the browser and select OK to confirm Select the Fieldbook bu
34. the computer Formatting the memory device will make it incompatible with System 1200 instru ments with firmware version 7 60 or earlier To become usable with System 1200 again the device would need to be reformatted on a System 1200 instrument To exit the screen without formatting the memory device press the ESC key This returns to the previous screen without running the format command Formatting a Go to Worki b Jobs amp Data Instrument memory device EI Work settings step by step EEG Transfer user objects EB Load firmware amp Apps CE Load licence keys ED Field to office 5 Format data storage devices sE contents of ASCII files CQ 0 030m 2DCQ 0 0l m 1D0Q 0 025m Fn abc 14 22 Format Data Storage Device prc System Viva TPS Working with Memory Devices From the Main Menu select User Tools amp other utilities Format memory devices Memory device Select the device to format Select OK to continue with the formatting 81 Viva TPS Working with Memory Devices Format Data Storage Device Mem Confirmation CF card will be formatted amp all data will be lost Note that this card wil then NOT be able to be used in System 1200 instruments The card must be re formatted on a 82 Select Yes to complete the formatting of the memory device OR Select No to cancel formatting of the memory device and return to Format Memory Device Once the formatting of the memory dev
35. tion list fil Server list fil GSI files gsi ASCII files for export from Job I SYSTEM Application files axx Firmware files fw Language files s Licence file key System files VivaSystem zip Viva TPS Working with Memory Devices 85 Viva TPS Uploading System Files 86 Appendix B Uploading System Files Tips and Tricks e Uploading objects can take some time Ensure that the battery Is at least 75 full before beginning the upload and do not remove the battery during the upload process e Applications will be installed in English and in any other language that Is already loaded onto the instrument If a new language Is loaded after an application has been installed the application will need to be reinstalled to become available in the new language e It is not possible to have more than three language files stored on the instru ment English is always available as the default language and cannot be deleted Copy the object to upload into the SYSTEM directory of the data storage device and insert the device into the instrument Firmware files use the extension fw application files use the extension axx and language files use an extension that is individual to each language Uploading firmware _ a rn os applications or languages step by step Format data storage devices Ov View contents of ASCII files Viva TPS Uploading System Fil
36. tton to generate a Fieldbook Report on the jobs to be imported To import the data to a project e In the General tab select an existing project from the list OR e Create a new project by right clicking and selecting New from the context menu 13 Select the Assign button to import the data into the selected project Viva TPS Leica Geo Office 93 Total Quality Management Our commitment to total customer satisfaction S pi E leica Geosystems AG Heerbrugg Switzerland has been z BS certified as being equipped with a quality system which m e i O ivi meets the International Standards of Quality Management 00 z 3 and Quality Systems ISO standard 9001 and Environmental 2 Z Management Systems ISO standard 14001 N c N Ask your local Leica Geosystems dealer for more information about our TQM program 2010 Leica Geosystems AG Heerbrugg Switzerland Leica Geosystems AG Heinrich Wild Strasse CH 9435 Heerbrugg e when it has to be right Cica Phone 41 71 727 3131 www leica geosystems com Geosystems
37. ture changes to Store The image can be overlaid with a sketch Click the EZ icon in the toolbar to activate sketching The 27 icon is displayed Additional icons are displayed to control the line weight style and colour of any lines you sketch on top of your image The image cannot be moved 7 e Press Prev to link the image with the last stored point and save it e Press Any to link the image with any point line or area of the current working Job and save it e Press No to save the image in the current working job without linking it to a point line or area K gt After the image has been stored you automatically return to the Capture Image with Camera screen Viva TPS SmartWorx Viva and Principles 47 Viva TPS SmartWorx Viva and Principles 48 Taking a screenshot Step Description Press the hotkey configured to User Screenshot capture or hold Fn while pressing A screenshot of the current SmartWorx Viva screen is created and displayed in the Image Notes screen CS The hotkey functionality is not available on the CS10 field controller The screenshot can be overlaid with a sketch Click the CS icon in the toolbar to activate sketching The Cr icon is displayed Additional icons are displayed to control the line weight style and colour of any lines you sketch on top of your image The image cannot be moved Press Store to save the screenshot A confirmation window opens The screenshot can be link
38. turn to Measure Target 1 in TPS mode Fo abe 14 39 IHdnPt Page e Meas to measure to target point 1 with TPS Screen automatically updates to Measure Target 2 e Repeat the previous steps to measure the other target points GPS to first enter GPS Survey before returning to the Measure Target screen then Meas to measure to each target point with TPS K When enough target points have been measured to calculate the station location the softkey Calc will appear Viva TPS Applications 67 Viva TPS Applications Measure Target 3 Point ID a Target height 1 5670 Hz angle 308 58209 V angle 100 02489 Slope distance Ti 14 02529 Station Results Results Station Quality Targets Plot Easting 764405 6320m Northing 2535120 9323m Elevation 400 3878m New orientation 308 587 29 E Apply the computed elevation for this Fa ae 1541 Trgt Page 68 e Calc to calculate the position of the station Setting the station e Review the results of the station setup e Set to set the station position and return to the Main Menu CS You have completed your setup with SmartPole 4 2 Survey Objective Surveying point objects fire hydrants light poles etc by choosing codes manually Surveying point Job Customer 1 Starting Survey objects step by Seema e Inthe Go to Work menu select Survey and step access Survey e Switch to the Code page Mens Near HdnPt Page Viva TPS A