GSM Alarm System AK24 AK24 User Manual

image

Contents

1. 4 8 Inquire host s external power status Input SMS 4 numbers for password W2 Reply SMS The host s external power status 4 9 Open close 20 seconds delay alarm function Open delay alarm SMS 4 numbers for password SD Close delay alarm SMS 4 numbers for password CD Factory set to alarm without delay that means it will alarm immediately when the host received alarm signal from detector if you want the host alarm after 20 seconds when trigger then edit the text message sent to the SIM card within the host the host will have a tick tick TWO tips respond for successful no information returned V Usage 5 1 Arm disarm by remote controller a Arm Press Wil on remote controller the host will make di sound the LCD display is on ta is twinkling 30 seconds later the host enters into arm mode and the dk is on If you want to arm the system quickly please press S b Partial arm press ey the host will make di sound the LCD display is on LI is twinkling 30 seconds later the host enters into partial arm mode and KI 1s on Press the oy the host will enter into partial arm mode immediately c Disarm Press mi to close the system the host enters into disarm status after the host makes di di sound and the mi is on 5 11 Disarm by keyboard on the host In arming status press Disarm button when SET O appears on the LCD display then Input 14 Alarm
2. mode OK Example Set zone 4 6 8 as alarm zones in partial arm mode input 468 OK then you will hear di di sound for confirmation When alarming zone 4 6 8 will alarm but other five zones will not alarm in partial arm mode That means you can disarm in some zones when you back home and others still keep in arm status 3 1 9 Set time of the alarm host After passing the verification of password press SET when SET appears on the LCD display Input 0 year month day hour minute second each with two numbers OK then you will hear di di sound for confirmation Example Suppose the present time 1s 15 43 and the date is 6 8 2010 input 01008061543 OK 3 2 0 Set cancel the time of arm disarm partial arm a Timing arm In arming status press SET when SET O appears on the LCD display then Input 1 time hour minute OK Example Set 23 43 as the arm time input 12343 OK then you will hear di di sound for confirmation To cancel it press 1 9999 OK in arm mode b Timing partial arm In partial arm status press SET when SET O appears on the LCD display then input 2 time hour minute OK Example Set 00 30 as the partial arm time input 20030 OK then you will hear di di sound for confirmation To cancel it press 2 9999 OK in partial arm mode c Timing disarm partial disarm In disarming status press SET whe
3. A Passive Infra red Sensor 1s an electronic device that detects the motlon or movement of some person or animal by sensing the heat emitted from the body Installation Alarm AK24 user manual Wireless PIR motion sensor Horizontal angle 90 110 degree Vertical al angle 30 50 degree Surveillance Area Install smoke gas detectors a Wired or wireless smoke detector This smoke detector detects smoke by a couple of infrared diodes which is suitable for detecting the smoke in house shop hotel restaurant office building school bank library and storehouse etc TEST BUTTON INDICATOR b Wired or wireless gas detector The product is ceiling mounted gas detector with high stability It is used for detecting leaking gas and suitable for the safety of residential house villas hotels boarding house etc Detecting the gas heavier than air installation height from floor 0 3m 1 0m semi diameter to gas sources lt 1 5m detecting the gas lighter than air installation height from ceiling 0 3m 1 0m semi diameter to gas sources lt 1 5m Alarm AK24 user manual Open or close manipulator Test button i py Power LED green DIAMETER Working LED 3M STA weny gt r 4 u at 11 s D S 1 0m RE aS GASOVEN 2 22 Wired alarm zones Alarm host has two wired alarm zones which display 25 26 on screen about connection pl
4. AK24 user manual password OK will disarm Note Keypad will become invalid when in alarm state 5 1 2 Auto detect doors and windows closed properly It will sound when delay arm or partial arm in a state of alarm from wired zone LCD will show 1 or 2 means wired zone 1 or wired zone 2 cable input are not normal This can use for the wired windows doors Magnetic Contact to check doors windows close properly before go out 5 2 Emergency alarm When an emergency alarm occurs press and the host will enter into emergency alarm status immediately and the siren will alarm for 90 seconds to inform the neighbors At the same time it will automatically dial the preset alarm phone numbers cycled for three times and send SMS of Emergency alarm 5 3 External power failure alarm When the system checks out that there is something wrong with the external power or the external power is off for more than 2 seconds it will enter into alarm status immediately At the same time the system will automatically dial the preset phone numbers cycled for three times and send the SMS of External power failed When the power supply is on the system will stop alarming immediately and send the SMS of External power 1s OK 5 4 LCD alarm instructions When alarming the screen display SMS TEL and alarm zone number OP means power failure OE means emergency call OF means fire 01 26 are wireless alarm zones 55 for t
5. Alarm AK24 user manual GSM Alarm System AK24 AK24 User Manual Version 2010 Sep 26th Alarm AK24 user manual Dear users Thank you for purchasing our products Please read through this manual before using this product so as to operate the product properly The GSM alarm system adopts the newest GSM network and Digital Signal Processing technology and is widely used in security field With SMS data transmission and voice platform of GSM network it really realizes wireless alarm control and remote managements and solves the limitation of wired data transmission in telephone and wired network Perfect structure convenient installation easy operation with wireless control keyboard are designed for the idea of people oriented which will make you feel easy and comfortable while use this system People is center technology is first is our company s action rule Customer Satisfaction is our consistent pursuit Perfect system excellent services sincere attitudes will bring you a new enjoyment Alarm AK24 user manual Contents DTS CO PE ANK NK PEN NAN EN ENG T 4 I SRDS AY AA og sors E NAN NGT IN ANG noo 2 1 Alarm Hos s section figure 2 2 Installation 2 21 Insert a valid SIM into the alarm host and install accessories 2 22 Wired zones 2 23 Main host with tamper alarm 2 3 Run LL OPET AON STEPS s s ra vo 11 3 1 Set by keyboard 3 1 1 Password verification 3 1 2 1 Set delete three mobile phone number
6. Timing control arm partial arm disarm 8 Program the alarm host by keyboard or SMS 9 Modify the name of 26 wireless guarding zones and inquire the status of alarm host by SMS demand 10 Define the 26 wireless guarding zones as arm partial arm by keyboard on the alarm host 11 with standby rechargeable battery 12 The alarm host automatically stores system status while its power 1s off 13 Connect with the alarm center through GSM network Specification a GSM GSM frequency 900 1800MHz or 850 1900MHz b Alarm method adopts SMS data transmission and voice platform c Stand by power consumption lt 0 6W b External power failure alarm e Alarm response time Less than 8s GSM in normality f The volume of siren More than 110db g Power Standby battery DC 8 4V lithium battery Standby battery working hours more than 15 Hours h Working conditions Operating temperature 10C 55 C Humidity S 95 no condensation 1 Dimension of alarm host Dimension 170mm Long x118mm Wide x40mm High II Installation 2 1 Main unit layout Alarm AK24 user manual GSM Antenna de FAKE 1806 LCD Speaker S amp R eypa JP Disarm a o o o Cover to amp o D A a A gt P K ng K fe Me Se RO g Ory Oo v So Cy KUN Alarm AK24 user manual Wireless signal receiving indicator Recording status indicator amp Record button Ta
7. ease check main unit layout IN1 IN2 Inserted the 4P cable which in standard package to the wired alarm connector the neighbour two lines can forms a wired zones The input alarm signal of the wired zone require contact close detector alarm output signal should be change from open state alarm to closed state alarm 2 23 Main host with tamper alarm Hold down the button of tamper switch when you want to put the host on the desks or walls It will alarm when host is moved Display 55 alarm ringing and inform master by SMS and remainder 2 3 Run The host will search GSM signal and the signal indicator flash in every 3 second regularly after start up After setting the time the screen will show the time the strength of the GSM signal arm or disarm status and com blinking When the host s external power supply is normal LCD backlight 1s on When the host detects there 1s no external power supply LCD backlight will be turn off automatically but for alarm partial alarm delay alarm and keyboard settings LCD backlight will keeps on 3 Operation steps 3 1 keyboard setting Note When setting by the keyboard every time you press the button you will hear di sound for confirmation Please press it again if theres no voice Press CLS button before inputting OK to cancel the input numbers If the LCD display shows FAIL check and reset it 3 1 2 1 Set delete three mobile phone numbers for SMS alarm a Se
8. he tamper alarm warning for 90 seconds 5 5 Alarm and Handle The siren sounds loudly for 90 seconds to inform the neighbors At the same time the system automatically sends SMS alert and auto dial the preset phone numbers by turn The user can listen to the pre recording warming voice and enter monitoring status which supports intercom function When answer the alarm call press any phone button can stop the host dialing the next preset alarm number The system will auto dial the next phone number if the phone line is busy or can t put through It will stop to call the next one when somebody answers the phone If nobody answers the phone the system will stop dialing after auto dialing circularly for three times VI Operation Cautions Make sure the eguipments have no water Install the system in a hidden place Turn off the power supply before inser take out the SIM card Connect the power supply firmly and provide good heat dissipation od a A v Don t install the system close to the objects which generate strong interference such as 15 Alarm AK24 user manual TV set and computer 6 Check all the detectors and their battery in time and change them when voltage is low 7 Inspect the GSM alarm system termly 8 This product is designed for the indoor use rather than outdoor use VII Encode the wireless detectors and Remote controller Wireless address code of Name A7 8 DO 13 D1 12 D2 11 D3 10
9. mote controller 0000000020559000000 00000000 0000000000 16 Appendix Operation guideline ee Mo ANO Paso rooooooosoc ovo voovvvovoooossosoovoovovoooocc000 so L 1 Instruction The alarm system adopts SMS data transmission and voice platform of GSM network to send control command and receive alarm remotely The system can be set delaved arm When a signal is detected by detectors the detectors will send alarm signal to host immediately then the host sends alarm SMS to its preset mobile phone numbers and meanwhile dials its preset telephone mobile phone numbers automatically and drive wiretap In addition the color LCD can show the time date and the status of arm disarm GSM signal power alarm etc With the LCD 1t 1s very easy for you to operate Following are the specific functions 1 Built in SIMCOM double frequency GSM module SIM300 or SIM340 2 With color LCD show screen and keyboard on the host 3 1 wireless SOS zone 1 fire alarm zone 24 wireless guarding zones 1 external power failure alarm zone 2 wired alarm zone 4 Send SMS to 3 group mobile numbers and call to 3 preset telephone numbers by turns while alarming 5 10 seconds self recording alarm voice will be sent out when alarming support monitor and intercom function 6 Arm disarm partial arm partial disarm by keyboard remote controller SMS or remote telephone mobile phone disarm by keyboard need password Alarm AK24 user manual 7
10. mper switch Power connector of the host Wired zone connector 2 21 Insert a valid SIM into the alarm host GSM wireless alarm system adopts SMS and voice data transmission platform of GSM network to send control command and receive alarm remotely Before installation make sure the SIM card is valid and turn off the power Insert pin or similar tools to the hole which near the SIM card slot to eject the SIM card holder and finish the installation after inserting the holder back with SIM card Install accessories Install the door window magnetic contact The principle of door window contact sensor The door window magnetic contact includes two parts The sensor will send the wireless signal to main unit immediately when the two parts depart more than 15 30mm The picture of the installation is as follows Double Faced Tape g p Alarm Indicator Alarm AK24 user manual In some circumstances the wired amp wireless Infrared Fence detector is more appropriate than magnetic sensors 1 e veranda picture window balcony boundary wall OE ERE Bini mise lt Wired or wireless glass break detector can also be used for window see below The sensitivity is adjustable Wireless scroll steel door magnetic sensor for scrolling steel door Installation Please see below picture It 1s triggered when the two parts are separated to 3cm 5cm Install PIR motion sensor PIR refers to passive Infra red
11. n SET O appears on the LCD display then input 3 time hour minute OK Example Set 09 30 as the disarm time input 30930 OK then you will hear di d sound for conformation To cancel it press 3 9999 OK in disarm mode d Check the the time of timing arm partial arm 12 Alarm AK24 user manual In state input CHECK e Timing alarm response After timing alarm setting will on and when the time come timing arm disarm partial arm SMS will send 3 2 1 Exit setting status In the setting status the host will exit automatically if there is no response within 15 seconds After setting successfully press ESC to exit 3 3 Recording Holding down REC then the light will on and begin 10 second record When finish the record release the button and then the light indicator turn off and quit the recording state IV SMS control command 4 1 Set three mobile phone numbers for SMS alarm Input SMS 4 numbers for password DD serial number mobile phone number Example Set 1388888888 as the first mobile phone number for SMS alarm The host s password is 1234 Send SMS 1234DD11388888888 Note The serial number shows alarm sequence must be 1 2 and 3 4 2 Set three phone numbers for auto dialing alarm Input SMS 4 numbers for password DD serial number phone number Example Set 01088888888 as the first phone number for auto dialing alarm The host s
12. password is 1234 Send SMS 1234DD401088888888 Note The serial number shows alarm seguence must be 4 5 and 6 4 3 Delete alarm phone numbers Input SMS 4 numbers for password DD serial number Example The hos s password is 1234 If you want to delete the first alarm phone number Send SMS 1234DD1 Note The serial number shows alarm seguence must be 1 2 3 4 5 and 6 4 4 Change host s password Input SMS 4 numbers for password DD 7 4 new numbers for password Example The initial password is 1234 if you want to set 5678 as the new password Send SMS 1234DD75678 4 5 Arm disarm SMS for remote arm 4 numbers for password A1 SMS for remote disarm 4 numbers for password A2 Example The host s password is 1234 If you want to set the host in arm mode 13 Alarm AK24 user manual Send SMS 1234A1 4 6 Change zone s name Input SMS 4 numbers for password DM zone s code 2 numbers changed name Reply SMS Changed zone s name Note The zone name zone is 1 6 characters zone number is two figures form 01 to 26 Example The password is 1234 If you want to change zone 06 s name to be PIR alarm for bedroom Send SMS 1234DM06 PIR alarm for bedroom Note Changed name should be less than 24 characters Zone s code 01 to 08 each code with two numbers 4 7 Inquire host s arm disarm status Input SMS 4 numbers for password W1 Reply SMS The host s arm disarm status
13. product AO to A 7 Label on the backside Main unit NC NC NC NC NC AO0 A 6 t i PIR sensor Magnetic AO A6 Match with the p wireless address code of the aj alarm host detector Remark 1 Request High level N connect with H l el El EE EE E 07 Request Low level N connect with L Sa No connect NC No request 16 Alarm AK24 user manual Appendix Operation Guideline By following steps you can operate it easily though 1t is the first time to use this product 1 Remove the SIM slot cover with screwdriver and insert a valid SIM card into the alarm host Please see 2 2 2 Make sure the power supply 1s connected turn on the host power switch Please see 2 3 3 Set the mobile phone telephone numbers for SMS alarm and auto dialing alarm For details please see 3 1 2 3 1 3 4 1 and 4 2 4 Set time of the alarm host for details please see 3 1 7 5 As per the operation instruction of page 13 encode the wireless detectors and remote controller to match with the alarm host and allocate the detectors to wireless zones separately Please make sure to record the corresponding zone number of each detector 6 Set zone type please see 3 1 6 for details 8 Change zone s name according to your needing Please see 4 6 for more details 9 Change password of the alarm host Please see 3 1 4 and 4 4 for more details 10 Se
14. s for SMS alarm 3 1 2 2 Check SMS alarm number 3 1 3 1 Set delete three phone numbers for auto dialing alarm 3 1 3 2 Check TEL alarm number 3 1 4 Change password of the alarm host 3 1 5 1 Set new host s ID 3 1 5 2 Check host s ID 3 1 6 Prohibit allow sending SMS while arm disarm the system by controller or keyboard 3 1 7 Set NC NO wired zones alarm 3 1 8 Set wireless zones to partial arm zones Only for zone 1 to zone 8 3 1 9 Set time of the alarm host 3 2 0 Set cancel the time of arm disarm partial arm 3 2 1 Exit setting status 3 3 Recording IV SMS control command aaa aa cies ecereaccedvcesscevessicsvesesvcaseeseussavencsuusesvenvastaatuves sate cessessensesions 13 4 1 Set three mobile phone numbers for SMS alarm 4 2 Set three phone numbers for auto dialing alarm 4 3 Delete alarm phone numbers 4 4 Change host s password 4 5 Arm disarm 4 6 Change guard zone s name Alarm AK24 user manual 4 7 Inquire hos s arm disarm status 4 8 Inquire hos s external power status 4 9 Open close 20 seconds delay alarm function V O 1 5 1 Arm partial arm disarm by remote controller 5 1 1 Disarm by keyboard on the host 5 1 2 Auto detect doors and windows closed properly 5 2 Emergency alarm 5 3 External power failure alarm 5 4 LCD alarm instructions 5 5 Alarm and handle VI Operation Cautions sssssassss0sa990ga 09070 ga genen konangan ananta en aren wangene go n ce Net ana 14 VII Encode the wireless detectors and re
15. t 3 1 3 2 Check TEL alarm number In TEL state input 4 5 6 CHECK 3 1 4 Change password of the alarm host After passing the verification of password press SET when SET PAS appears on the LCD display Input 7 new password OK Example Set 4321 as the new password Input 7 4321 OK then you will hear di di sound for confirmation Note The initial password is 1234 must be four numbers 3 1 5 1 Set new ID of the alarm host After passing the verification of password press SET when SET ID appears on the LCD display Input 0 six new ID numbers OK Note the initial ID is 000000 Example Set 123456 as the new ID Input 0 123456 OK then you will hear di di sound for confirmation 3 1 5 2 Check host s ID In D state input CHECK 11 Alarm AK24 user manual 3 1 6 Prohibi allow sending SMS when arm disarm the system by controller or keyboard After passing the verification of password press SET when SET appears on LCD display input 9 OK then you will hear di di sound for confirmation 3 1 7 Set NC NO wired zones alarm In ID state NC NO wired alarm shift 8 OK 3 1 8 Set wireless zones to partial arm zones Only for zone 1 to zone 8 After passing the verification of password press SET when SET TYPE appears on the LCD display Input zone numbers 1 8 When there is illegal intrusion the zones will alarm in partial arm
16. t the mobile phone number 10 Alarm AK24 user manual After passing the verification of password press SET button when SET SMS appears on the LCD display input serial number mobile phone number OK Example Set 1360000000 as the first mobile phone number for SMS alarm Input 1 1360000000 OK then you will hear di di sound for confirmation According to the method you can finish the setting of the other two mobile phone numbers Note Serial number can only be 1 2 3 and the number 1 is the first mobile phone number For SMS alarm The phone No must be less than in 20 numbers b Delete the mobile phone number Input serial number OK then you can cancel the mobile phone numbers 3 1 2 2 Check SMS number In SMS state input 1 2 3 CHECK 3 1 3 1 Set delete three phone numbers for auto dialing alarm a After passing the verification of password press SET button when SET TEL appears on the LCD display Input serial number phone number OK Example Set 1360000000 as the first phone number for auto dialing alarm Input 4 1360000000 OK then you will hear di di sound for confirmation Note Serial number can only be 4 5 6 and the number 4 is the first phone number for auto dialing alarm The phone number can be mobile phone or telephone but mustn t be more than 20 numbers b Delete the phone number Input serial number OK then you can cancel i
17. t time of arm disarm according to your needing Please see 3 1 8 for more details For specific operation please read this manual carefully 17

Download Pdf Manuals

image

Related Search

Related Contents

User Manual  Sony S-Frame DPF-WA700 User's Manual  TDSHーBA 〝 取扱説明書  Government of Tamil Nadu  State Industries SBN85390NE User's Manual  Phonix IPDAIRGN  Manuel d`installation et d`entretien ITV10*0-X305, ITV20*0  Handbook Best practice DroppeD oBject ManageMent  Hifonics Mercury IV  ESTUFA ELÉCTRICA DE DOBLE HORNO  