1. 7 2 2 Set Device Parameters e OFA IFA INA and IFC Set Temperature When the Device is maintaining a constant Temperature the user can set the Device Temperature by clicking on Set gt Device Temperature menu item as show below OFA_1_Measure_2011 04 07_21 27 Measure OFA_1_Measure_2011 04 07_21 27 A Measure is running NOTE The user can set the temperature of OFA IFA or INA only when they are not running a program e Ultra Low Freezers Set Temperature The user can set the Freezer Temperature by clicking on Set gt Freezer Temperature menu item as show below ULTF_Unit_1_Measure_2011 04 07_21 14 Measure Unit Data Options Er Freezer Temperature Freezer Time ULTF_Unit_1_ 3 L Measure is running 84 y DI Set Time The user can also set the Freezer Time by clicking on Set gt Freezer Time menu item Ecco Voyager 7 2 3 Read Device Data The user can read Data from Devices which have in built memory for Data Logging These Devices include Ultra Low Freezers and Co2 Incubators e Read Data Log The user can read the Device Data Log by clicking on Unit Data gt Data Log ULTF_Unit_1_Measure_2011 04 07_21 42 Measure File Run Set li 5 40 8 ULTF_Unit_1_Meas i i Measure is running 84 a aa e Read Event Log The user can read the Device Event Log by clicking on Unit Data gt
2. Thank you for purchasing this software Please read this manual thoroughly to familiarize yourself with the many unique features and exciting innovations we have built into your new equipment Esco provides many other resources at our website www escoglobal com to complement this manual and help you enjoy many years of productive and safe use of your Esco products For Technical Service contact North America Esco Technologies Inc 2940 Turnpike Drive Units 15 16 e Hatboro PA 19040 USA Toll Free USA and Canada 888 375 ESCO Tel 215 441 9661 Fax 215 441 9660 us escoglobal com usa escoglobal com Rest of World Esco Micro Pte Ltd 21 Changi South Street 1 e Singapore 486 777 Tel 65 6542 0833 e Fax 65 6542 6920 www escoglobal com mail escoglobal com Esco Voyager User Manual Version A 1 Released April 2011 User Manual Voyager Monitoring Programming amp Datalogging Software Copyright Information Copyright 2011 Esco Micro Pte Ltd All rights reserved The information contained in this manual and the accompanying product is copyrighted and all rights are reserved by Esco Esco reserves the right to make periodic minor design changes without obligation to notify any person or entity of such change Voyager is registered trademarks of Esco Material in this manual is provided for informational purposes only The contents and the product described in this manual including any appendix addend
3. Measure File View Run Set Unit Data Mr Deals E Mail Alerts ULTF_Unit_1_Measure_2011 i Measure is running The Voyager will prompt the below window Auto Save Settings O Disable Enable Document Period Every day Date Time 10 12 12 PM Save To Spreadsheet Save Path E Woyager Files Auto Email Receiving Address myAddress myCompany com Export HTML Save Path E Yoyager Filed Make the required changes and click OK to save the changes Ecco Voyager
4. Event Log e Sensor Data The user can read the real time sensor values by clicking on Unit Data gt Sensor Data View Unit Data Options l Event Log Data Log 4 Sensor Data 7 3 Email Alerts If email alerts are enabled the Voyager will notify the user via Email incase of any Alarm conditions like communication errors with device or device parameters going beyond the specified High Low limits To enable email alerts click on Options gt Email Alerts menu item ULTF_Unit_1_Measure_2011 04 07_22 06 Measure File View Run Set Unit Data Mo 14 53 22 ULTF_Unit_1_Measure_2011 i Measure is running A a a The Voyager will then prompt the user to options window as shown below Email Alerts Options Data Logging E Mail Alerts O Disable Enable Receiving Address ImyAddress myCompany com Click on Enable and enter the email addresses of the users who will be notified in case of errors Multiple Email Addresses can be entered with comma separators NOTE For Email Alerts to be sent the user has to previously enter the Email Settings in the Configuration Window See Section Mail Setting for more info Monitoring Programming and Datalogging Software Ecco 7 4 Data Logging The user can change the Data Logging settings while the measure is running by clicking on Options gt Data Logging ULTF_Unit_1_Measure_2011 04 07_22 06
5. Windows 2000 XP 7 and Windows 2003 Server e Memory 512 MB e Hard disk space 1 GB e Interface USB RS232 e Prerequisite Software NET Framework 2 0 included Windows Installer 3 1 included Internet connection is required for auto mailing feature RJ45 RS485 to USB Converter requires a correct driver to work e Windows 98 amp ME for Windows 98 and Windows Me incompatible with Voyager e Windows XP for Windows XP Vista and 7 32 bit e Windows Vista x64 for Windows Vista and 7 64 bit e Linux for Linux incompatible with Voyager The driver is included in the USB Serial Converter ATC 820B folder in the CD DVD 2 2 Device Requirements Lexicon Ultra Low Temperature Freezer v 1 currently unavailable Celculture CO Incubator CCL v 1 3 1 Isotherm Forced Convection Oven OFA v 1 Isotherm Forced Convection Incubator IFA v 1 Isotherm Natural Convection Incubator INA v 1 currently unavailable Isotherm Low Temperature BOD Incubator IFC v 1 The device require RS485 port connection Please check the firmware version of the device before attaching it to the Voyager system 2 3 CD DVD Menu Options Install Voyager to install the Voyager software Read Voyager Manual to open the attached Voyager manual Adobe Reader required Install Adobe Reader to install the Adobe Reader Software Read Converter Manual to open the attached RJ45 RS485 to USB converter manual A
6. the below picture The corresponding row of the selected step point is highlighted in Step table OFA_Unit_1 Program Editor Edit OFA_Unit_1 s Program i Program saved Selected step point o a 3 e mM th v a E u gt i 20 Mins 99 7 C i I 45 Time Minutes Corresponding Row of Program Steps Annotations Selected Step Temperature C Step Time Minutes 43 5 99 7 3 1378 Click Program gt Edit to edit the Graph You can also select a step by selecting a row in Step table Selecting a row in Step table will highlight the corresponding step point in Graph editor e insert a Step Point Double click at the position where the step point is to be added or Right Click at the position click Add Point A step point will be inserted at that position e Delete a Step Point Select a step point Press Shift Delete key or click menu Edit gt Delete Point or right click on the point you want to delete and click Delete Point Voyager will prompt confirming message Click Yes to delete the selected step point To delete all step point click menu Edit gt Delete All Points e Move Step Point There are 2 ways of moving a step point o One is to move Step Point in Graph editor Select the Step Point and drag it to the required position Monitoring Programming and Datalogging Software Ecco o Another is edit position in Step Tabl
7. Device Log For Devices with built in data logging capabilities the user can export the Device Data Log by Clicking on Export Data Log gt Device Log gt Flash Data The User can also view the Event Log of the Device by Clicking on Event Log ULTF_Unit_1 Set Temperature Current Tempera Open Graph Measure Measure is Running Device Export Data Log voyager Log gt Fash Dat Event Log Ecco Voyager Chapter 6 Program Management A program is a sequence of one or more temperature steps which will be maintained by the device The user can create a program using Voyager and export it to the device or save it into an external file which can be used for future programming Program can also be imported from an external file or device NOTE Programs are only for devices with program functions i e OFA IFA and INA 6 1 Open Program To open a new Program right click the mouse on the Device you want program and Click on Program as shown below ESCO WORLD CLASS WORLDWIDE OFA_Unit_1 Click to start measure Program Measure gt Device gt Add Device This will open the Program editor as shown below Monitoring Programming and Datalogging Software Ecco 6 2 Edit program gt OFA_Unit_1 Program Editor DER Fle Edt View Chat OS i QO SD o oe na PRE ROR Rc Ree Message Panel Edit OFA_Unit_1 s Program Double check to add port Double click with sh
8. Mail Configurations Devices Mail Setting Mail Setting Users SMTP Host smtp MyCompany com Smtp MyCompany Com SMTP Port 587 25 Sender Name _amin MyCompany com MyN ame MyCompany com Password Require SSL Set Email settings for Data Logging and Email Alerts Services e SMTP Host Set SMTP server address Like Smtp MyCompany com e SMTP Port Port of SMTP e Sender Name Sender s Email Address Like MyName MyCompany com e Password Sender s Email Password Require SSL Some SMTP servers need SSL 4 4 3 Users Configurations Devices Users Mail Setting User Name Role admin Admin oper Operator ECCO Voyager This configuration block shows the user list having access to Voyager The user can have one of the two levels of access e Operator has access to all functions except configurations e Admin has access of all functions e Add User Click Add User button to open new user dialog as following User Editer User Name Role Operator Note Password Confirm e Options o User Name User name of the new user cannot be same with existed users o Role Role of the new user o Note Note of the new user o Password o Confirm Confirm of password must be same with password o Click OK button to save new user e Delete User Click Delete User button to delete selected user e Edit user Click Edit User bu
9. Monitor Interval 2 00 Minutes Measurement Details Measure Note Set Point Run Program Run Existing Device Program Program Load Program From File settings File Path Running Time Runnin Start Immediately g O Start At O Endat Time Data Logging Document Period Every day 3 Data Logging Settings Date Time 11 39 ep Save To Spreadsheet Save Path C Voyager Files Auto Email Receiving Address MyEmailAddress myCompnay com Export HTML Save Path C VYoyager Files The user has to enter the following options in the Measure Configuration dialog e Measure name Not empty Name of the measure e Device Device to be addressed e Monitor interval Rate at which data will be acquired e Measure note Notes of the measure Oo Program or Set Point Monitoring Programming and Datalogging Software Ecco For programmable devices the user can either run the device at a constant temperature In which case he has to enter the Set Point or he can run a program In case he wants the device to run a program he can either choose to run the program already loaded into the device or he can export a new program from a file NOTE These options are not available for Non Programmable devices ULT Freezers CO Incubators and IFC e Running Time Specify running time perio
10. d o Start Immediately If this option selected measure starts when OK button clicked o Start At Ifthis option selected measure will start at the specified time o End At If this option checked measure will end at the specified time Else measure will run until user clicks stop menu e Data Logging Enable Data Logging If enable checked documentation services saving spreadsheet sending email or exporting html will be executed in specified period o Document period Period type of datalogging Can be every day every week or every month o Date Time Detailed period value Date is different according to document period The following table list date values of Period values Document period Date values Every day Every week Sunday Monday Tuesday Wednesday Thursday Friday Saturday O Save to Spreadsheet Enable auto save measure data to spreadsheet file These spreadsheet files are saves at Save Path o Auto Email Enable auto send email of measure data The receiving email is specified by Receiving Address o Export HTML Enable export measure data to html files These files are saved at Save Path under Export HTML ECZO Voyager 7 2 Measure Window Once the measure is started the Voyager keeps acquiring data from the Device and updating the Measure Graph The user can view the measure window by right clicking on the Device Block and clicking on Open Graph menu item OFA_Unit_1_Measur
11. dobe Reader required e View All Files to view the files and folder structure in the CD DVD Monitoring Programming and Datalogging Software Ecco 2 4 Installation Steps 1 Run Setup Double click setup exe 2 Checking Prerequisites If the Operation System doesn t have NET framework 2 0 and or Windows Installer 3 1 installed the software s setup form will appear ic EscoVoyager Setup For the following components indows Installer 3 1 Please read the following license agreement Press the page down key to see the rest of the agreement SUPPLEMENTAL END USER LICENSE AGREEMENT FOR MICROSOFT SOFTWARE Supplemental EULA IMPORTANT READ CAREFULLY The Microsoft operating system components accompanying this Supplemental EULA including any online or electronic documentation DS Components are subject to the terms and conditions of the agreement under which you have licensed the applicable Microsoft operating system product described below each an End User License Agreement or EULA and the terms and conditions of this Supplemental EULA BY INSTALLING al View EULA for printing Do you accept the terms of the pending License Agreement If you choose Don t 4ccept install will close To install you must accept this agreement Accept Dont Accept EscoVoyager Setup For the following components NET Framework 2 0 Please read the following license agreement Press the page down key to s
12. e Select the Step Point in Graph editor The corresponding row of the selected step point is highlighted in Step table Edit Temp and Step Time value in Step table The step point s position will change according to Temp and Step Time value 6 2 2 Edit Annotation The following are operations about editing annotation e Insert an annotation Right click at the position in the Graph editor where you want to add the Annotation or press the Shift key and double click A text editor prompts at the click position 300 0 Keen Temperature C a o o 45 60 Step Time Minutes Type annotation text and click key enter to confirm editing Press key Esc or click other place to cancel annotation editing The new annotation is shown below hn o o o o g 2 Ss 150 0 o 2 E o E 60 Step Time Minutes e Select an annotation Click annotation to select it Selected annotation will be highlighted Corresponding row of the selected annotation also will be highlighted Ecco Voyager Selected Annotation o 9 3 4s mM I o e E o Corresponding row of the selected Annotation Program Steps x Y Text 1 7 67 60 67 Step 1 2 27 06 111 77 Step 2 3 47 06 150 79 Step Point 3 You can also select an annotation by select a row in Annotation table Selecting a row in Step table will highlight the corresponding annotation in Graph editor e Delete an Annotation Select an An
13. e_2011 04 07_10 58 Measure File View Run Set Options AE Ss SS GL on Ba Se OFA_Unit_1_Measure_2011 04 07_10 58 i L Measure ix running Message Panel Measure Curve Graph o o m w k 2 k w e E w R Measure Data Measure Data Time Run Time Minutes Actual Setpoint Note Measure OFA_Unit_1_Measure_2011 04 07_10 58 COM1 9600 8 1 None Start Time 10 58 43 AM End Time Infinite Measure data table columns definition e Time Measure record time format like 20011 04 5 13 34 56 e Run Time Minutes Minutes from begin to record time e Actual Actual sensor value e Set Point The Set Point Value e Note Editable Note the record Operations on graph are listed at section 0 6 2 4 Operations in Graph 7 2 1 Pause Resume Stop Measure o Pause To Pause the Measure either click Run gt Pause menu item or click on the Pause icon on the toolbar OFA_1_Measure_2011 04 07_19 52 Measure File View Run Options MAMAR ESPN ASA OFA_1_Measure_2011 04 07_19 52 2 Measure is running vu Monitoring Programming and Datalogging Software Ecco e Resume To Resume either click Run gt Continue menu item or click on the Resume icon on the toolbar OFA_1_Measure_2011 04 07_19 52 Measure e Stop To Resume either click Run gt Stop menu item or click on the Stop icon on the toolbar OFA_1_Measure_2011 04 07_19 52 Measure
14. ee the rest of the agreement MICROSOFT SOFTWARE SUPPLEMENTAL LICENSE TERMS MICROSOFT NET FRAMEWORK 2 0 MICROSOFT WINDOWS INSTALLER 2 0 MICROSOFT WINDOWS INSTALLER 3 1 Microsoft Corporation or based on where you live one of its affiliates licenses this supplement to you If you are licensed to use Microsoft Windows operating system software the software you may use this supplement You may not use it if you do not have a license for the software You may use a copy of this supplement with each validly licensed copy of the software View EULA for printing Do you accept the terms of the pending License Agreement If you choose Don t Accept install will close To install you must accept this agreement Accept Don t Accept Click Accept button to continue with the installation and the software setup will commence 6 EscoVoyager Setup i 4 Installing NET Framework 2 0 6 EscoVoyager Setup 5 Setup must reboot before proceeding Choose Yes to reboot now or No to manually reboot later Ecco Voyager 3 Esco Voyager Installation Click next to continue ie EscoVoyager Welcome to the EscoVoyager Setup Wizard a The installer will guide you through the steps required to install EscoVoyager on your computer WARNING This computer program is protected by copyright law and international treaties Unauthorized duplication or distribution of this program or any portion of it may result in severe civi
15. functionality is available only for Laboratory Ovens and Incubators OFA IFA INA ESEO Voyager 5 4 Measure Management Left click on the Device Block or right click and select Measure gt Start menu item This will open the Measure Configuration window Once the measure is started the user can Pause Resume or Stop the measure by right clicking on the device block and clicking on the respective menu items OFA_Unit_1 Click to start measi Program Device Pause Resume Stop See section Measure Management for more details 5 5 View Device Status Once the measure is started the user can view the real time sensor readings on the device block These values are updated at the measure monitor rate selected while configuring the measure ESCO WORLD CLASS WORLDWIDE OFA_Unit_1 Set Temperature 30 0 C Current Temperature 35 0 C Measure is Running Add Device Monitoring Programming and Datalogging Software Ecco 5 6 Export Data Log The user can export the data acquired by Voyager into an Excel or Text file by clicking on the Export Data Log gt Voyager Log gt Data Log The user can also export the communication log of Voyager by clicking on Communication Log OFA_Unit_1 Set Temperature 300 Current Temper i Open Graph Measure is Running Program Measure Device Export Data Log gt Voyager Log gt Data Log Communication Log 5 7 Export
16. ift ke 770 add annotation 3 1 Pressing alt key to drag and move point or anmotation Pres3 delete key to delete annotation Press f2 key to edit annotation o o o en u 3 u 5 a a E v Ke 45 60 Step Time Minutes Temperature C Step Time Minutes 1 5 0 19 2 102 0 18 3 130 17 Press key Enter to confirm editing Press key Esc or click any other place to cancel editing The Program Editor has the following Sections e Message Panel Prompt operation guide error messages and warning messages e Graph Editor Displays program curve Step points and annotations position can be moved in this area The X axis is total time minutes of a step point The Y axis is temperature value of the step e Step Table List steps in the program Steps values can be edited in this table o Temperature C Temperature value of the step Editable o Step Time Minutes Heating time of the step Editable e Annotation Table List annotations Annotations position value and text can be edited Program Steps Annotations x T Text 1 7 67 60 67 Step 1 2 27 06 111 77 Step 2 o X X axis value Editable o Y Y axis value Editable o Text Text of annotation Editable Ecco Voyager 6 2 1 Edit Step Point The following are operations for editing a step point e Select a Step Point Click the step point to be edited in the Graph editor The selected step point is marked with red circle round as shown in
17. l or criminal penalties and will be prosecuted to the maximum extent possible under the law Cancel 4 Select Installation Folder Click Next gt to continue ie EscoVoyager Select Installation Folder The installer will install EscoWoyager to the following folder To install in this folder click Next To install to a different folder enter it below or click Browse Folder C Program Files Esco EscoVoyager Browse Disk Cost Install EscoWoyager for yourself or for anyone who uses this computer C Everyone Just me Cancel lt Back 5 Confirm the installation by clicking Next gt ie EscoVoyager Confirm Installation The installer is ready to install EscoVoyager on your computer Click Next to start the installation Cancel lt Back Monitoring Programming and Datalogging Software Ecco 6 The installation will commence ie EscoVoyager Installing EscoVoyager EscoWoyager is being installed Please wait 7 Finish installation Click Close to complete installation ie EscoVoyager Installation Complete EscoWoyager has been successfully installed Click Close to exit Please use Windows Update to check for any critical updates to the NET Framework Ecco Voyager La Chapter 3 Connecting the Devices Esco Voyager connects to devices using RS485 communication protocol and EscoBus addressing protocol through either RS232 or USB po
18. mation Esco Voyager is a software system for monitoring and programming multiple Esco devices The main features include e Remote Monitoring and Data Logging o Automatic continuous monitoring of device parameters Temp CO2 RH etc Viewing and graphing device parameters in real time Saving and exporting log data in various formats Automatic emailing of log data at user defined intervals Download of data logs from equipment memory only for devices with built in data logging memory e CO2 Incubators Ultra Low Temperature Freezers e Alarm o Alarms when exceeding a user defined parameter limit o Automatic email alerts o Documentation of all alarms with time date stamp e Remote programming and equipment configuration o Development of programs using a graphical interface for subsequent download to device memory only for equipment with program functions i e Forced Convection Laboratory Ovens and Incubators o Configure devices remotely set points time local alarm limits etc O O O O Esco Voyager can be used for the following equipment e Lexicon Ultra Low Temperature Freezer Celculture CO Incubator Isotherm Forced Convection Oven Isotherm Forced Convection Incubator Isotherm Natural Convection Incubator Isotherm Low Temperature BOD Incubator Monitoring Programming and Datalogging Software Ecco ESEO Voyager Chapter 2 Installation 2 1 System Requirements e Operation system
19. notation Press key Delete or click menu Edit gt Delete Annotation system will prompt confirming message Click Yes to delete the selected annotation e Edit an Annotation Select an annotation Press key F2 or click menu Edit Edit Annotation The annotation editor will display like inserting an annotation Change annotation text and press key Enter to confirm editing 6 2 3 Import and Export Program Program can be stored in 2 ways e External file Program can be saved to or imported from external program file prg e Device Memory Program can be saved to or Imported from device s memory The File menu contains sub menus to load or save program Menu Description CEI N Import Program METI Send program to Device s memory Monitoring Programming and Datalogging Software Ecco 6 2 4 Operations in Graph The following is operations about graph These functions are available in tool bar Same operations are available in measure form Menu Description E S O Shrink Vertical C O ae Z S E nn E ECZO Voyager Chapter 7 Measurement 7 1 Measure Configuration Left click on the Device Block or right click and select Measure gt Start menu item OFA_Unit_1 Click to start meas Program Device This will open the Measure Configuration window Measure Configuration Measure Name U nit_1_Measure_201 1 04 07_11 39 Device OFA_Unit_1 gt
20. rt Voyager also uses common CAT5 cable more commonly known as LAN cable with RJ45 connectors as a connecting wire between devices also PC and device Since common PC do not normally use RS485 protocol a converter is required either RJ45 RS485 to USB or RJ45 RS485 to RS232 Note At the end of the daisy chain terminate the connection To set the Escobus address for the device please check the device s user manual Monitoring Programming and Datalogging Software Ecco ESEO Voyager Chapter 4 Operating Esco Voyager 4 1 Starting Esco Voyager Double click Esco Voyager shortcut on the desktop or click START menu and select All Programs Esco Voyager Esco Voyager to start Esco Voyager At Startup the Voyager will display a Login dialog Box Login Esco Voyager ECCO WORLD CLASS WORLDWIDE Enter user name and password and click OK button to login Esco Voyager If this is the first time the software run then enter these information User Name admin Password admin After login successfully the main form will be displayed ESCO WORLD CLASS WORLDWIDE Monitoring Programming and Datalogging Software Ecco 4 2 Locking and Unlocking Esco Voyager In main form click menu File gt Lock or press Ctrl L to lock Voyager Enter password to unlock ESCO WORLD CLASS WORLDWIDE ECCO WORLD CLASS WORLDWIDE Spike is locked please entes password to unlock Uo ene
21. sli O Password Cx 4 3 Working in the Background When the user closes main window Voyager will continue to run in the background to monitor the devices and send alerts Esco Yoyager Is Still Running x Esco Yoyager will continue to run so that you can acquire data from chambers and receive alerts 2 46PM The user can either close the Voyager or open the main window by right clicking on the Voyager icon present in the system tray YE 2 48pm 4 4 Configuration To open configuration click on Settings in the main window Configurations dialog is shown as below Ecco l Voyager 4 4 1 Devices Configurations Devices Devices Mail Setting Device Name Device T ype Controller Type COM Port EscoBus Address Users OFA_1 OFA OFA COM1 5 This configuration block gives a consolidated view of all the devices and allows the user to Add Edit and Delete Devices e Add New Device Click on New Device to open the New Device dialog This is same as adding a device from the Main Window see next chapter New Device Device Name Device Type Info Controller Type COM Type COM Port EscoBus Address o Edit Device Click on Edit Device to edit the selected device e Delete chamber Click on Delete Device to delete selected device Note Deleting a Device will delete all related measures Monitoring Programming and Datalogging Software Ecco 4 4 2
22. tton to open edit user dialog as following User Editer Role Operator Note Click OK to save Monitoring Programming and Datalogging Software l Ecco ESEO Voyager Chapter 5 Device Block 5 1 Adding a Device from the main window Vayago ECCO WORLD CLASS WORLDWIDE Sprem u locked please enter password to unlock User Name admin Password New Device Device Name Device Type N Device Type Info Controller Type COM Type Programmable COM Port EscoBus Address The user has to enter the following options Device Name A suitable Name for the Device Device Type Select Type Of Device COM Port Select COM Port the Device is connected EscoBus Address Set EscoBus address of the Device Click OK to save For each device added a device block is added on the main window as shown below Monitoring Programming and Datalogging Software Ecco N Esc x Fie gs Her 5 2 Edit Delete Device Right click on the Device Block and click on the Device gt Edit menu item to edit the properties of the Device To delete the Device Click on Device gt Delete Program Measure gt A Delete 5 3 Open Program Editor Right Click on the Device block and click on the Program menu item to open the Program Editor Program Measure 2 Device gt See section Program Management for more details NOTE Programming
23. um attachment or inclusion are subject to change without notice Esco makes no representations or warranties as to the accuracy of the information contained in this manual In no event shall Esco be held liable for any damages direct or consequential arising out of or related to the use of this manual Table of Contents Chapter 1 Product Information 5 Chapter 2 Installation 5 2 1 System Requirements 5 2 2 Device Requirements 5 2 3 CD DVD Menu Options 6 2 4 Installation Steps Chapter 3 Connecting the Devices 11 Chapter 4 Operating Esco Voyager 11 4 1 Starting Esco Voyager 12 4 2 Locking and Unlocking 12 4 3 Background Working 12 4 4 Configuration 13 4 4 1 Device 14 4 4 2 Mail 14 4 4 3 User 17 Chapter 5 Device Block 17 5 1 Adding a Device 18 5 2 Edit Delete Device 18 5 3 Open Program Editor 19 5 4 Measure Management 19 5 5 View Device Status 20 5 6 Export Data Log 20 5 7 Export Device Log 21 Chapter 6 Program Management 21 6 1 Open Program 22 6 2 Edit Program 23 6 2 1 Edit Step Point 24 6 2 2 Edit Annotation 25 6 2 3 Import and Export Program 26 6 2 4 Operations in Graph 27 Chapter 7 Measurement 27 7 1 Measure Configuration 29 7 2 Measure Window 29 7 2 1 Pause Resume Start Measure 30 7 2 2 Set Device Parameter 31 7 2 3 Read Device Data 31 7 3 Email Alerts 32 7 4 Datalogging Monitoring Programming and Datalogging Software Ecco ESEO Voyager Chapter 1 Product Infor

Download Pdf Manuals

image

Related Search

Related Contents

Philips SMARTSPOT Recessed spot light 57971/17/16  LLA-1B ¥99,000 警告 注意 STC-1A ¥35,000 STC-SH-1A  BALAI 5550m EXPRESS 3 MANNEL D`UTILISATION  Owner`s Manual (General)  Tecumseh AVB5558EXN Performance Data Sheet  User Manual TDS 500D, TDS 600B & TDS 700D Digitizing      notice console cs 4000-12 seed monitor cs 4000-12  Manual - Goldair  

Copyright © All rights reserved.
Failed to retrieve file