Home

Mobeye Argos User Manual - Compound Security Systems

image

Contents

1. rmobeuc Manual i200 Mobeye Argos SW version 6 n Attention Very important This user manual contains important guidelines for the installation and usage of the Mobeye Argos Please read these thoroughly before you start using the Mobeye Argos In case of damage caused by disregarding the guidelines the warranty becomes void The user must regularly check the proper functioning of the Mobeye Argos The manufacturer cannot be held liable for any damage or loss caused by any incorrect use or incorrect functioning of the Mobeye Argos Safety guidelines The permitted ambient temperature during operation may not be exceeded not lower than 10 C and not higher than 55 C The device is intended for use in dry and clean places Protect the device from moisture heat and water splashing Not intended for external use The guidelines for the battery usage must be regarded Do not expose the device to strong vibrations Do not let it fall from height Do not use in an environment where any inflammable gases vapours or dust are present or could be present Repair of the device may only be carried out by people trained for Mobeye repair If the device must be repaired only original replacement components may be used The use of different parts may lead to damage of the Mobeye Argos Use in accordance with the regulations The purpose of this device in accordance with the regulations is the generation
2. The action can be interrupted at any time by twice pressing The entry indication and siren are off as factory default Look at the next chapter how to activate them To de activate the Mobeye Argos movement detector with your code e Enter your code e Press OK The light switches to green and a confirmation melody is played The system needs to be switched on and off using the same code the installation code and user code are not interchangeable 3 2 ALARM MESSAGE CONFIRMATION AND LISTEN IN When the armed system detects a movement it first waits for the entry delay period and then it alarms During the entry delay the GSM module starts to establish a connection to the network If the system was not disarmed the alarm messages follow First an SMS text message is sent to all programmed alarm numbers next a phone call is made to the numbers When you answer the phone a beep tone is heard Confirm using 1 It is possible to confirm the phone call by answering the phone and pressing 1 The other alarm numbers will not be called afterwards Listen in using 9 It is possible to start a listen in connection by answering the phone call and pressing 9 You will then be able to hear anything in the immediate vicinity of the Mobeye Argos If the siren was set to loud it is stopped After two minutes one hears two short beeps if one presses 9 again the listen in is extended by another
3. 9 5 POWER FAILURE DELAY TIME The power failure delay time defines the time that the power fails before an alarm is initiated If the power is restored within the delay time no alarm is sent The delay time can be set between 0 and 60 minutes As default the delay time is set to 1 9 6 AUTHORISATIONS AND REMOTE CONTROL When connected to an external power the GSM module is active all the time able to receive SMS commands This enables both programming and remote control Remote control actions are arming disarming and switching the outputs As prerequisite for remote control the controlling telephone number needs to be authorised A maximum of ten numbers can be authorised via keypad or SMS command If it is not clear what memory positions are available it is possible to add a new number by the SMS command ADDTELA The new number takes the first free position To receive a list with the authorised numbers please refer to paragraph 14 3 SMS commands for remote control no code is necessary but numbers need to be authorised Arm ARM Disarm DISARM Switch on output 1 1 Switch off output 1 17 10 OUTPUTS The Mobeye Argos has two outputs O1 and O2 These relay outputs can switch external devices The maximum load is 2A 30V per output Output 1 is free to use for an external device Switching the relay can be done in several ways after an alarm upon arming upon disarming or remote via SMS or
4. 07 Entry indication 0 off 1 2 JO LED on 08 Siren 0 off 1 on 0 09 Exit indication 0 off 1 on 1 12 SMS on off 0 off 1 on 1 13 Call on off 0 off 1 on 1 50 User code 4 digit 8888 60 Actual time hhmm 9 1530 61 Actual date yyyymmdd e g 20140331 62 Automatic arming time hhmm 0 to delete 0 empty 63 Automatic disarming time hhmm 0 to delete 0 empty 79 Inactive time PIR 00 60 min 5 The menu can be left from any position by twice pressing 4 2 INSTALLATION CODE The installation code is the 4 digit code for switching on off and programming the settings or activating the special functions Factory default is 1111 It is possible to change the user code to any 4 digit number Please change the code to make the unit more secure 4 3 USER CODE The Mobeye Argos offers the possibility to set a personal 4 digit user code for just arming and disarming the system It is not possible to change the settings with the user code The system needs to be switched on and off using the same code the installation code and user code are not interchangeable Factory settings for the user code is 8888 This code can be changed by the installation code or user code menu number 50 We recommend that you change this code to make the unit more secure 4 4 SMS CUSTOM TEXT It is possible to add a custom text in the SMS text messages to identify the Mobeye Argos unit that sent the
5. 73 Input SMS INACTIVEINP1 02999 qmm i Inactive time Keypad 74 input 2 SMS INACTIVEINP2 02999010 22 Setting Menu Options Factory default command bs Pes Keypad 75 0 999 lt gt Delay time input 1 SMS DELAY 1 n Keypad 76 0 999 lt sec gt Delay time input 2 SMS DELAY2 1 Power failure delay Keypad 77 00 60 min 1 time SMS DELAYPOW Delay temperature Keypad 78 00 60 min 1 alarm SMS DELAYTEMP qm Keypad 79 Inactive time PIR SMS INACTIVEPIR 0 999 min 5 81 Pulse time output 1 SMS TOI 1 9999 sec 0 Pulse time Keypad 82 siren output 2 SMS TO2 Jussu age 120 Repeat Keypad 84 0 99 lt hours gt 4 P SMS REPEAT Power failure Keypad 86 0 off 1 on 1 ON message SMS POWERSMS ON OFF TEL1 Keypad 101 Tat RUNGE SMS TEL1 TEL2 Keypad 102 SMS TEL2 Tel nummer 103 SMS Tel nummer TEL4 Keypad 104 SMS TELA Tel nummer TEL5 Keypad 105 SMS TELS Tel nummer Delete telephone Keypad 101 105 0 number SMS DEL 1 DEL5 201 210 Tel nummer e TEL of ADDTELA Delete authorised Keypad 201 210 0 number SMS DELA 1 DELA 10 1 RC 2 ARMED 3 DISARMED 4 Keypad 89 INTRUDER 5 Behavior output 1 TEMP 1 RC RC ARMED SMS OUTPBEHAVIOR DISARMED INTRUDER TEMP UNA Keypad ide
6. Enter the installation code e Press menu e Press 511 e Press OK e Aconfirmation beep is heard First the green light will be flashing After about 30 seconds the light will be on continuously In this mode the sensor test can be done each time the sensor detects a movement a repeating beep will sound 11 Leave the test by entering OK twice 6 5 TEST GSM NETWORK STRENGTH Before using the Mobeye Argos is it advised to test the GSM signal strength at the location e Enter the installation code e Press menu e Press 512 e Press OK The Mobeye Argos now switches on the GSM module and searches for all available networks It also checks the network strength of the SIM card provider in the device As soon as the GSM network is found the light will turn green The GSM signal strength for the network your SIM is using can be gauged from the LED indicator LED Description Green during 30 seconds Signal is very good Flashing green Signal is good Red Signal is weak Flashing red Searching no valid SIM card or SIM card is not pin code free or no signal The telephone number at memory position 01 will receive an SMS text message containing all existing GSM networks sorted by provider It also tells the strength of each network This search function can take a few minutes If you want to leave the function before it is ready please press twice Warning In the e
7. of SMS text messages and telephone calls after detection of motion by the motion detector if the measured temperature outreaches the programmed limits after the activation of one of the inputs or after an internal trigger switching the outputs after an alarm or via incoming call SMS Other uses are not permitted Table of Content Introduction To get ready in four steps Step 1 SIM Card Step 2 inserting the batteries Step 3 Program the phone numbers Step 4 Check the settings Intruder alarm operation Switching on and off Alarm message confirmation and listen in Intruder alarm basic functions Configuration Installation code User code SMS custom text Telephone numbers SMS ON OFF CALL ON OFF Sensor sensitivity Entry delay Entry indication Siren Exit indication Interval test message Set actual time and date Automatic time based arm disarm Inactive time after a movement detection Temperature alarm Configuration Monitoring the temperature limits Adjusting the temperature Delay time Alarm repeat Advanced options Request the list of settings Reset to factory settings Leave the menu Position of Mobeye Argos Test GSM network strength Connecting sensors devices and external power Inputs Configuration Alarm text Input type Input delay time Inactive time PIR sensor on off Alarm repeat External power supply Configuration 16 Sensitivity PIR Power failure message Power failure del
8. 1 x 90 x 35 mm LxWxH Batteries 4 x CR123 Lithium 3 0 V Power battery operated 50 pA short peaks of max 2 A Power ext powered 50 mA short peaks of max 2 A 25 Declaration of Conformity Herewith we Mobeye declare that the product Mobeye i 200 is in compliance with the essential requirements of the following European standards EU Directives Directive 73 23 EEC low voltage directive Directive IEC EN 50130 Electromagnetic compatibility Directive 1995 5 EC R amp TTE Radio amp Telecommunications Terminal Equipment The conformity with the essential requirements of 1995 5 EC has been verified against ETSI EN 301 489 1 V1 5 1 ETSI EN 301 489 7 V1 2 1 ETSI EN 301 511 V9 0 2 CENELEC EN 60950 2001 Mobeye B V Poeldonkweg 5 5216 JX s Hertogenbosch The Netherlands Name J P K van de Vijver Position Managing Director Signature Date 1 Augustus 2012 Support For support on technical problems regarding Mobeye Argos please contact info mobeye eu This manual is published by Mobeye All rights the translation included are reserved Any reproduction either photocopy microfilm or saved in an automated data dictionary only after written approval of the Publisher Reprinting even in summary is prohibited This user manual meets the technical requirements at the moment of printing Changes in technology and equipment are reserved Copyright 2014 by Mobeye version i200N
9. E TIMES If an output is used the time this output is activated can be set between 1 and 999 seconds If the setting is set to 0 the output does not return to its previous state automatically An authorised number can switch it back by the SMS command O10OFF see 9 6 In the factory settings the duration of the pulse time for output 1 is 1 and for output 2 120 10 3 SWITCH BEHAVIOR The reason why output 1 is switched can be configured Choices are switch by remote control RC switch when arming the Mobeye Argos ARMED switch when disarming the Mobeye Argos DISARMED switch upon an intruder alarm alarm on PIR IN1 or IN2 switch upon a temperature alarm temp For remote control switch via SMS commands please refer to 9 6 the senders telephone number needs to be authorised In the factory settings the switch behavior of output 1 is set to RC 10 4 AUTHORISING TELEPHONE NUMBERS For remote control by telephone arm disarm switch outputs the telephone numbers need to be authorised A maximum of ten numbers can be authorised via keypad or SMS command In case it is not clear which memory position is free it is possible to add a new number by the SMS command ADDTELA The new number takes the first free position To receive a list with the authorised numbers please refer to paragraph 14 3 19 11 MOBEYE INTERNET PORTAL The Mobeye Argos sends GSM messages to the pre set contact persons It is also possibl
10. L140303 26
11. an incorrect entry the light turns red and a short beep sounds The menu can be left from any position by twice pressing Following settings are possible 3 Be sure the wires are laid between the tapped holes and the wall of the casing before closing 4 7 2 5 o menu mobeye Argos Description Options Factory setting nu nr 86 Power failure message 0 off 1 on 1 77 Power failure delay time 00 60 lt min gt 1 201 Authorise telephone number Telephone number 0 to delete 2 10 9 2 16 9 3 SENSITIVITY PIR Using an external power source the internal PIR sensor will react slight slower after detecting movements even when the sensitivity is set to high Be sure the sensor is positioned well so the intruder can be seen while walking or working Please test the PIR positioning to ensure the PIR detects you in the areas you are trying to secure 9 4 POWER FAILURE MESSAGE Upon a power outage the batteries take over functioning A power failure SMS text message is sent to the first telephone number The GSM module turns to the low power status meaning it closes and only establishes network connection in case it needs to send a message alarm test battery low The power failure message can be deactivated OFF As factory default the power failure message is set to ON
12. ay time CO CO cO DOOD aAaa n c A 9 6 10 10 1 10 2 10 3 10 4 11 12 12 1 12 2 13 14 14 1 14 2 14 3 15 Authorisations and remote control Outputs Configuration Duration of outputs Switch or pulse times Switch behavior Authorising telephone numbers Mobeye Internet Portal Programming via SMS text messages Program mode How to Program by SMS Complete list of settings Reports and lists Status request List of settings Authorisation list Issue solving and technical data 1 INTRODUCTION Mobeye Argos is an easy to install alarm system that will notify you about y a an activation using the built in GSM communication module 4 To use the Mobeye Argos you will need a SIM card from any network Typical applications are the security of places without any power supply or the temporary security of properties The Mobeye Argos has the following features Alarm notifications after movement detection In case of the detection of an intruder the Mobeye Argos will send an SMS text message to your phone s The Mobeye Argos will also call the phone numbers in order to be sure the message is not missed It is also possible to set on the siren sound After an alarm the Mobeye will be in standby status for about 5 minutes Following the standby period the Mobeye will resume alerting you to new movement Alarm notifications after detection
13. bers as list 24 15 ISSUE SOLVING AND TECHNICAL DATA Issues Error Possible reason Oplossing Mobeye Argos cannot be switched on You hear an error tone the red light is turned on shortly No valid Telephone number was entered Enter a valid number The light is flashing red during switching on No valid SIM card was entered or the SIM card was not made pin code free Check the SIM card It is impossible to change the settings After entering your personal code followed by menu the error tone is played and the light turns red Mobeye is activated Switch off the Mobeye Argos No GSM signal during the GSM test No network is available belonging to the SIM cards provider Choose another network provider The light remains red You entered an incorrect installation or user code three times Wait 10 minutes and then re enter the correct installation or user code You do not receive an SMS with the settings Telephone number is not correct Re program the telephone number Change the menunr 06 to 01 For other questions please refer to the site www mobeye eu Technical data GSM Quad Band EGSM 850 900 1800 1900 MHz compatible to the ETSI GSM Phase 2 standard Output power Class 4 2W 900 MHz Class 1 1W 1800 and 1900 MHz Temperature range 10 C until 55 C Weight ca 290 gram incl batteries Dimensions 16
14. call Output 2 O2 is configured for an external siren This output reacts similar to the internal siren if this is set to silent O2 does not react Upon a loud alarm it switches for 2 minutes 1 Replace the white 2 Insert the 2 wires through the hole 3 Be sure the wires are laid grommet with the rubber s to the terminal connectors press between the tapped holes and ring using a tool the orange pins the wall of the casing before closing the casing 10 1 CONFIGURATION To change the settings please follow the instructions e Enter your 4 digit code factory setting is 1111 e Press menu gt light turns green e Enter the menu number see list below e Press e Enter the new setting e Press OK The light switches off a confirmation melody is played gt 225 1213 5 8 Ut mobeye mobeye Argos Argos et In the event of an incorrect entry the light turns red and a short beep sounds The menu can be left from any position by twice pressing Following settings are possible Me Description Options Factory setting nu nr 81 Duration of output 1 1 9999 sec 0 82 Duration of output 2 1 9999 sec 120 201 Authorised telephone number Telephone number 0 to delete 2 10 83 Behavior output 1 1 RC 2 ARMED 1 3 DISARMED 4 INTRUDER 5 TEMP 18 10 2 DURATION OF OUTPUTS SWITCH OR PULS
15. casing before 1 press the orange pins closing When using a second input connect this to input 2 8 1 CONFIGURATION change the settings please follow these instructions 1 B Enter your 4 digit code factory setting is 1111 4 5 6 e Press menu light turns green 7 8 e Enter the menu number see list below Prem e Press e Enter the new setting a ES e Press The light switches off a confirmation melody is played In the event of a incorrect entry the light turns red and a short beep sounds The menu can be left from any position by twice pressing Following settings are possible Menu Description Options Factory setting 71 Input type input 1 0 off 1 normally closed 2 normally opened NO 72 Input type input 2 0 off 1 normally closed 2 normally opened NO 73 Inactive time input 1 0 999 min 5 74 Inactive time input 2 0 999 min 5 79 Inactive time PIR 00 60 min 5 70 PIR on off 0 off 1 on On 75 Delay input 1 00 999 lt sec gt 1 76 Delay input 2 00 999 sec 1 84 Repeat time 0 99 hours 4 8 2 ALARM TEXT Custom alarm texts can be programmed These texts have a maximum length of 20 characters The following texts are programmed as factory default Triggered input 1 TEXT1 alarm 1 Triggered input 2 TEXT2 alarm 2 The alarm text can b
16. e SMS TEST days qo Keypad 07 0 off 1 on LED Enty indication ENTRYBEEP ON OFF LED OLOFE Keypad 08 0 off 1 on EROR SMS SIREN ON OFF O OFE aA Keypad 09 0 off 1 on Exit indication SMS EXITBEEP ON OFF 1 Keypad 12 0 off 1 on sS on SMS SMSALARM ON OFF MON Keypad 13 0 off 1 on SMS CALLALARM ON OFF 30 00 01 general Select ARC SMS ARG 00 01 00 Keypad 31 ARC client number SMS ARCGLIENTNR 5 digit client number ARC telephone Keypad 32 number SMS ARCCALLERID 41 000 050 0 50 Change minimum SU EIU tom off temperature 999 off SMS LTL 10 to 450 000 050 0 to 50 C 110 101 10to Change maximum us 1 C off temperature 999 off SM5 HTE 10 to 50 01 09 1 to 9 Correction efactor Keypad 49 11 19 1 to 9 C temperature 00 no correction SMS TEMPOFFSET 9 tot 9 Keypad 50 oer User code SMS USERCODE 4 digits 8888 Keypad 60 Actual time SMS SETTIME hhmm Actual date Keypad en yyyymmad SMS SETDATE Automatic arming Keypad 62 hhmm time SMS TIMEARM hhmm delete by 0 Automatic Keypad 63 hhmm disarming time SMS TIMEDISARM hhmm delete by 0 Keypad 70 0 off 1 on PIR on off SMS PIR ON OFF 1 ON Keypad 71 0 off 1 NO 2 Input type input 1 NC NO SMS TYPEIN1 OFF NO NC Keypad 72 0 off 1 NO 2 Input type input 2 NC NO SMS TYPEIN2 OFF NO NC Inactive time Keypad
17. e battery strength and send the message 2 GET READY IN FOUR STEPS To get started with the Mobeye Argos only four steps are needed 1 Place the SIM card in the Mobeye Argos Make sure this SIM card is not secured by a PIN code 2 Insert the four batteries 3 Enter at least one phone number in the Mobeye Argos 4 Check the settings In this chapter these steps are explained 2 1 STEP 1 SIM CARD To use the Mobeye Argos a SIM card from any network is needed On this SIM card the PIN code security needs to be disabled or 0000 If you have a SIM card with PIN code you can disable or change this using any mobile phone and change the PIN code security Please consult the manual for that mobile phone for the procedure The SIM card needs to be inserted before the batteries When using a prepaid SIM card take note of the available credit Additionally it is wise to set a recurrent test message in the menu so the card will be used at least once a month e Open the back cover e Insert the SIM card in the holder For opening closing move the cover slightly 2 2 STEP 2 INSERTING THE BATTERIES Insert the four lithium 3 0 volt batteries CR123 When replacing the batteries all settings remain unchanged After inserting the SIM card and the batteries the Mobeye Argos will perform a self test taking 1 minute During the test the light is red If the light is flashing red a pr
18. e changed by SMS command see chapter 12 for explanation SMS command TEXT1 CODE TEXT1 free text SMS command TEXT2 CODE TEXT2 free text 14 8 3 INPUT The input type defines the character of the inputs IN1 and IN2 This can be Normally Open NO or Normally Closed NC If an input is set to NO the alarm will be triggered as soon as the terminals of the input are closed If the input is set to NC the alarm is triggered if the connection between the input terminals is broken The default input type is set to NO 8 4 INPUT DELAY TIME The input delay time defines the time that the inputs are triggered before an alarm is initiated If the input returns to the non alarm status within the delay time no alarm is sent The delay time can be set between 0 and 999 seconds As default the input delay time is set to 1 second 8 5 INACTIVE TIME The inactive time defines the time the movement sensor input 1 or input 2 is not active after an acti vation If the time is set to 0 minutes the input is active again immediately after returning to the non alarm status If the time is set to e g 30 minutes the input remains inactive for the first 30 minutes If the input is again or still activated after these 30 minutes a new alarm message is sent The inactive time can be set between 0 and 60 minutes As default the inactive time is set to 5 for all inputs 8 6 PIR SENSOR ON OFF If the inputs are in use it could b
19. e to connect the system to the Mobeye Internet Portal In this secured internet environment the Mobeye Argos systems can be administered The portal offers various functions 1 the portal dispatches alarm messages to contact persons SMS and or mail which are set in the portal Different persons can be set for alarm messages versus technical message 2 The name and location can be set in the portal This name is used in SMS and mail messages 3 the portal will check the receipt of test messages keep alive in case the message was not received on time it sends an exception message Please contact Mobeye for more information It is also possible to connect the Mobeye Argos to an alarm receiving centre ARC if this ARC has an SMS receiver Please contact Mobeye for more information 20 12 PROGRAMMING VIA SMS TEXT MESSAGES Almost all options can be set via the keypad It is also possible to program by sending SMS commands to the SIM cards telephone number in the Mobeye Argos 12 1 PROGRAM MODE If the unit runs on external power it is always in program mode ready to receive SMS commands For programming a battery operated Mobeye Argos first switch to the program mode e Enter your 4 digit code e Press menu gt light turns green e Enter 21 e Press OK First the light flashes red interval ca 1 sec As soon as the light turns green the Mobeye Argos is able to receive SMS messages Afte
20. e useful to de activate the integrated movement sensor PIR The Mobeye Argos will then cease activating alarms when movement is detected until this function is reinstated As factory settings the PIR is ON 8 7 ALARM REPEAT See 5 5 for explanation 15 9 EXTERNAL POWER SUPPLY Although the Mobeye Argos is designed to run on batteries it is possible to use an external power supply 9 24VDC In this mode the module is always in connection with the GSM network The advantage of external power is the longer battery lifetime to receive power failure messages and the possibility to perform remote actions like arm disarm switch the outputs ask status reports and to program it via SMS commands Be aware the PIR sensor will be slightly less sensitive when using external power supply O 1 Replace the white grommet 2 Insert the 2 wires through the hole with the rubber ring using a to the inside part and in to the two tool connectors press the orange pins V to Ground to oo Article 10027 black wire with white line is black wire is 9 1 CONFIGURATION To change the settings please follow these instructions e Enter your 4 digit code factory setting is 1111 e Press menu light turns green e Enter the menu number see list below e Press OK e Enter the new setting e Press OK The light switches off a confirmation melody is played In the event of
21. ed anymore Or to start a listen in connection Note The first telephone number is required the others are optional 4 6 SMS ON OFF By default the Mobeye Argos sends alarm notifications via text message and calls to the preset contact persons By turning off the SMS the unit will only call after the movement sensors sends an alarm Regardless of this setting the temperature alarm always sends an SMS including the actual temperature 4 7 CALL ON OFF By default the Mobeye Argos sends alarm notifications via text message and calls to the preset contact persons By turning off the CALL the unit will only send an SMS text message as alarm notification It is not possible to switch off both the SMS and the call 4 8 SENSOR SENSITIVITY The detectors sensitivity can be changed to a high or low value 1 High 2 Low In the high sensitivity mode each detection will generate an alarm In the lower sensitivity mode the alarm will be generated only when the detector is activated twice in any 15 second period This mode prevents false alarms in case of e g draught and is most suitable if the sensor is directed towards an open space 4 9 ENTRY DELAY It is possible to choose from 5 entry delay times 1 15 30 45 and 60 seconds The entry delay is the time between the moment of detection and the moment of sending the first SMS text message Important note If the GSM network has low signal strength the time can be longer as the network connect
22. ion may not be established within the time of the entry delay 4 10 ENTRY INDICATION No entry indication is set as the factory default It is possible to hear an indication beep during the entry delay This can be used as a reminder that the Mobeye is in active mode It is also possible to just let the LED indicator flash a few times as an indication for the user 4 11 SIREN After the entry delay the siren can sound for two minutes At the same time the SMS text messages and telephone calls will be sent At soon as the Mobeye is switched off the siren will stop The siren is set to silent as the factory default 4 12 EXIT INDICATION Upon arming the system you have one minute to leave the room The PIR is not active yet and an exit indication sounds It is possible to change this to a silent exit time A short beep is heard and the LED flashes red during the exit time 4 13 INTERVAL TEST MESSAGE The Mobeye Argos can send test messages Through these keep alive reports you will be informed about the status of your Mobeye Argos You can set the interval between the test reports This is adjustable between 0 no test reported and 30 every 30 days a test message Note the interval of 1 day will result in a daily test message the exact time between the messages will be about 24 hours The smaller the interval between the test reports the shorter is the battery life The test message only works if the system is on or a temperature
23. limit is set 4 14 SET ACTUAL TIME AND DATE If the system is to be armed automatically the internal clock time needs to be correct Some Telecom providers offer this in the network to be synchronised by the Mobeye Argos during the start up and after sending test messages It is possible to set the time and date manually To view the clock time send a list of the settings to the first programmed phone number CODE MENU 10 Ok 4 15 AUTOMATIC TIME BASED ARM DISARM The Mobeye Argos can be armed and or disarmed based on a daily time schedule If the exit indication was set to silent the system makes no noise during arming and disarming The first telephone number needs to be set before the arming and or disarming time can be set 4 16 INACTIVE TIME AFTER A MOVEMENT DETECTION The PIR inactive time is the time the movement sensor is inactive after having seen and reported movement If the time is set to 5 minutes the sensor will only report new movements after a minimum of 5 minutes after the previous movement The inactive time can be set in minutes from 0 to 999 As factory default the inactive time is set to 5 5 TEMPERATURE ALARM 5 1 CONFIGURATION To change the settings please follow these instructions e Enter your 4 digit code factory setting is 1111 e Press menu light turns green e Enter the menu number see list below e Press OK e Enter the new setting e Press OK The ligh
24. message The second part of the SMS text message contains a standard text like Mobeye alarm or Test message The custom text will be written before the standard text This custom text max 20 characters is programmed by sending an SMS to the Mobeye Argos Changing the custom text cannot be done via the keypad only via sending an SMS text message Switch the Mobeye Argos into the programming mode In this mode the GSM module is switched on and is able to receive messages e Enter your 4 digit personal code factory setting 1111 e Press menu e Press 21 gt light turns green e Press OK First the light flashes red interval ca 1 sec As soon as the light turns green the Mobeye Argos is able to receive SMS messages To program the custom text send an SMS in following structure 1111 NAME myowntext 1111 stands for the installation code 1111 NAME is a standard command capitals Replace myowntext by a self defined text max 20 characters Be aware of the space after 1111 and the colon after NAME You will hear two short beeps in case of a correct command Leave the menu by pressing OK twice 4 5 TELEPHONE NUMBERS Up to five telephone numbers can be programmed in to the Mobeye Argos In the event of an alarm the Mobeye Argos first sends an SMS text message to all numbers next they are called It is possible to confirm the call after which the other numbers will not be call
25. ntification text SMS NAME 20 characters Mobeye Alarm text input 1 Keypad SMS TEXT1 20 characters Alarm 1 Alarm text input 2 Keypad SMS TEXT2 20 characters Alarm 2 Program method using the keypad CODE menu nr option Program method SMS in program mode CODE COMMAND OPTION Or several commands at once CODE COMMAND OPTION COMMAND OPTION COMMAND OPTION 23 14 REPORTS AND LISTS The programmed settings and the Mobeye Argos status can be requested as SMS text message via the keypad or SMS command for SMS be sure the unit is in program mode 14 1 STATUS REQUEST The status can be requested via CODE menu 501 OK or by sending an SMS with the content CODE STATUS The originator of the request receives the armed not armed status the status of the inputs power and batteries as SMS text message 14 2 LIST OF SETTINGS The basic settings can be requested via CODE menu 10 OK or by sending an SMS with the content CODE SET The originator of the request receives the list of basic settings The advanced settings can be requested via CODE menu 11 OK or by sending an SMS with the content CODE SETA The originator of the request receives the list of advanced settings 14 3 AUTHORISATION LIST The list with authorised numbers for remote control can be requested via CODE menu 200 Ok or by sending an SMS with the content CODE ANL The originator of the request receives the authorised num
26. oblem with the SIM card is detected A reason could be no SIM card was placed or the PIN code security of the SIM card was not disabled Close the Mobeye Argos using the 4 screws 2 3 STEP 3 PROGRAM THE PHONE NUMBERS You need to program at least one phone number in the unit as alarm number e Enter your 4 digit code factory setting 1111 e Press menu e Enter 101 e Press OK e Enter the phone number e g 0712345678 or 0044712345678 e Press OK The light turns green and a confirmation melody is played The Mobeye Argos is ready to use 2 4 STEP 4 CHECK THE SETTINGS The settings can be sent to the programmed telephone number as SMS text message In this way you also check the correct working of the SIM card e Enter your 4 digit code factory setting 1111 e Press menu e Enter 10 e Press OK Within ca 30 seconds the programmed phone number will receive the list with settings 3 INTRUDER ALARM OPERATION 3 1 SWITCHING ON AND OFF To activate the Mobeye Argos movement detector use the installation code or user code e Enter your code e Press OK The light turns red shortly and an indication tone is started This repetitive tone will last during the exit delay of 60 seconds As soon as the acoustic signal stops the Mobeye Argos is active If the code is entered incorrectly 3 times the indicator turns red and the Mobeye Argos will be blocked for 10 minutes
27. of out of range temperature It is possible to program a minimum and or maximum temperature alert in to the Mobeye Argos The system will monitor the actual temperature of its environment and send an alert as soon as the temperature reaches the limit Battery operated or using the mains Although the Mobeye Argos is designed to run on batteries it is possible to use an external power supply When powering the Mobeye Argos with mains it notifies the first set telephone number if the power fails and that it has switched to battery backup It is also possible to remotely control the system when using mains power Connecting external sensors and devices In addition to the integrated movement sensor and temperature sensor external sensors can be connected The Mobeye Argos can also switch external devices connected to it via the outputs when an event triggers it like an alarm or incoming call Private numbers or Mobeye Internet Portal The Mobeye Argos sends alarm messages to a maximum of five telephone numbers As an option the Mobeye Argos can be connected to the Mobeye Internet Portal which is explained in chapter 11 Low battery message The Mobeye Argos will send an SMS text message when the batteries need to be replaced When receiving this message you need to change the batteries as soon as possible although the Mobeye Argos remains functioning for a short time following the message Even when the Mobeye Argos is unset it will measure th
28. r five minutes there is a time out and a beep is heard Leave the program mode earlier by pressing twice 12 2 HOW TO PROGRAM BY SMS Be sure the unit is in program mode Send an SMS message with following content CODE COMMAND OPTION The CODE stands for the installation code Factory setting is 1111 Do not forget the space between CODE and COMMAND The complete scheme with SMS commands is listed chapter 13 The commands are case sensitive Several commands may be combined in one SMS message with a maximum of 160 characters by placing a between the commands CODE COMMAND OPTIONZCOMMAND OPTIONZCOMMAND OPTONE A confirmation melody is played to indicate a correct command In the event of an incorrect command a beep is heard Examples code is 1111 To switch off exit indication 1111 EXITBEEP OFF To set the minimum temperature lower limit to 5 degrees 1111 LTL 05 Or both commands in one message 1111 EXITBEEP OFF LTL 05 21 13 COMPLETE LIST OF SETTINGS Setting Menu Options Factory default command Keypad 00 ET Installation code SMS INSTCODE 4 digits 1111 a Keypad 03 Sensitivity PIR SMS SENS 1 high of 2 low 1 low Keypad 04 Entry delay SMS ENTRYDELAY 1 15 30 450r60 15 Interval test Keypad 05 0 1 2 3 or 30 0 messag
29. s way you also check the correct working of the SIM card e Enter the 4 digit installation code factory setting 1111 e Press menu e Enter 10 e Press OK Within ca 30 seconds the programmed phone number will receive the list of settings The advanced settings are listed in the advanced setting list e Enter your 4 digit installation code factory setting 1111 e Press menu e Enter 11 e Press OK Within ca 30 seconds the programmed phone number will receive the list with advanced settings 6 2 RESET TO FACTORY SETTINGS It is possible to reset the Mobeye Argos to factory settings e Enter your 4 digit installation code factory setting 1111 e Press menu e Enter 99 e Press OK After several seconds a short confirmation tone is heard The installation code is also reset to 1111 6 3 LEAVE THE MENU The menu can be left from any position by twice pressing 6 4 POSITION OF MOBEYE ARGOS The built in motion sensor has a 360 detection pattern and has a range of about 8 meters The Mobeye Argos can be positioned both vertically as horizontally It can be mounted to the wall put down on its side in a cabinet put down with its sensor upward or downward In case you wish to hang the Mobeye Argos the pre punched holes can be opened in order to hang it on screws In order to check the positioning of the sensor a sensor test can be executed e
30. t switches off a confirmation melody is played In the event of an incorrect entry the light turns red and a short beep sounds The menu can be left from any position by twice pressing Following settings are possible Menu Description Options Factory setting nr 41 Minimum temperature limit O00 050 0 to 50 C 999 off 110 101 10 to 1 999 off 42 Maximum temperature limit 000 050 0 to 50 C 999 off 110 101 10 to 1 999 off 49 Correction factor 01 09 1 to 9 00 temperature 11 19 1 to 9 00 no correction 78 Delay temperature alarm 00 60 min 1 84 Repeat time 0 99 hours 4 5 2 MONITORING THE TEMPERATURE LIMITS The Mobeye Argos is able to send a temperature alarm as soon as the actual temperature reaches a programmed min or max level This function can be used independently of the motion detection As soon as the temperature is too high or too low an SMS text message is sent followed by a telephone call As long as the out of range temperature remains the report will be repeated every four hours factory default Once the temperature is back to normal the Mobeye Argos confirms this to you This function is active as soon as a temperature limit is programmed By resetting the limits the function becomes inactive 5 3 ADJUSTING THE TEMPERATURE The built in temperature sensor may have a standard deviation of the actual temperat
31. two minutes By pressing 9 the call is confirmed as well and the other alarm numbers will not be called afterwards 4 INTRUDER ALARM BASIC FUNCTIONS The Mobeye Argos settings can be changed via the keypad First the method of programming is discussed next the explanation of the settings This chapter describes the settings for the all in one basic system Advanced options like using the external inputs outputs or external power supply can be found in chapter 7 and further 4 1 CONFIGURATION To change the settings please follow these instructions e Enter your 4 digit code factory setting is 1111 0 2 3 e Press light turns green 4 5 6 e Enter the menu number see list below 9 e Press o e Enter the new setting mabeye Argos e Press The light switches off a confirmation melody is played In the event of an incorrect entry the light turns red and a short beep sounds The menu can be left from any position by twice pressing Following settings are possible Menu Description Options Factory settings nr 00 Installation code 4 digit code 1111 101 1 tel number Tel number 102 279 tel number 0 to delete 103 3 tel number 104 4 tel number 105 5 tel number 03 Sensitivity PIR 1 2 1 04 Entry delay 1 15 30 45 or 60 15 05 Interval test message 0 30 days 0 no message
32. ure In this case the deviation will be similar at all temperatures It is possible to correct the temperature deviation in the Mobeye Argos In the SMS setting summary you see the reported temperature If a correction is specified it is processed in the displayed temperature the correction factor itself is displayed separately Example Mobeye temperature 13 Actual temperature 14 To correct this deviation one degree should be added 5 4 DELAY TIME The temperature delay time defines the duration a temperature limit is exceeded before an alarm is initiated If the temperature returns to the non alarm status within the delay time no alarm is sent The delay time can be set between 0 and 999 minutes As default the temperature delay time is set to 0 minutes 5 5 ALARM REPEAT In order to emphasize the urgency of the alarm messages the temperature alarm and alarms on the inputs 1 and 2 can be repeated As long as the alarm status has not returned to the inactive status the SMS alarm will be repeated after the alarm repeat time as long as the alarm SMS is ON In the repeated temperature alarm message the actual temperature is mentioned as well to follow the temperature development The time can be set between 0 and 24 hours As default the alarm repeat time is set to 4 hours 10 6 ADVANCED OPTIONS 6 1 REQUEST THE LIST OF SETTINGS The settings can be sent to the set telephone number as SMS text message In thi
33. vent of a weak signal the Mobeye Argos can still be used but there is a risk that messages cannot be sent or will be received with a delay In case of no signal it is advised to try a different network 12 7 CONNECTING SENSORS DEVICES AND EXTERNAL POWER In addition to the integrated movement sensor and temperature sensor external sensors can be connected as alarm input The Mobeye Argos can also switch external devices connected to it via the outputs when an event triggers it like an alarm or incoming call And although the Mobeye Argos is designed to run on batteries it is possible to use an external power supply in order to report power failure and to remotely control the system In following chapters the inputs outputs and external power settings are explained Please find below the architecture of the main unit Piezo siren SIM card holder GSM status LED Status LEDs Temperature sensor LI LLLI 2002 2 5555 52 2 9 oO 13 8 INPUTS External sensors can be connected to the inputs Upon closing or opening an input the Mobeye Argos will send an alarm message to the set alarm numbers factory default SMS and call so 1 Replace the white grommet 2 Insert the 2 wires of an external 3 Be sure the wires are laid with the rubber ring using a tool sensor through the hole to the inside between the tapped holes and and in to the two connectors of input the wall of the

Download Pdf Manuals

image

Related Search

Related Contents

Adafruit 954  取扱説明書  Notebook PC Manuale Utente  projectwise security - Bentley Communities  Samsung SGH-F300 Brugervejledning  Table of Contents 4 7 8 10 12 16 16 17 17 18 18 19 19 19  Dicota Code Backpack 11-13  Toro Topdresser 2500 (44507) Specifications  FRACOD Manual V11  be.ez La Robe mini Classic black/orange  