Home

User Manual - ADFWeb.com

image

Contents

1. J Note If you want that the Modbus register status is written only when data are changed the Poll Time of the row must be O Note TA If the field On change is checked and the Poll Time is different from 0 the converter sends the Write request cyclically and also when the data is changed ADFweb com S r l User Manual Document code MN67664 ENG EtherNet IP Modbus TCP Master Revision 1 000 Page 17 of 26 Industrial Electronic Devices UPDATE DEVICE By pressing the Update Device button device and also the Firmware if necessary If you don t know the actual IP address of the device you have to use this procedure Turn off the Device Put Dip2 of Dip Switch A in ON position Turn on the device Connect the Ethernet cable Insert the IP 192 168 2 205 Press the Ping button Device Found must appear Press the Next button Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn off the Device Put Dip2 of Dip Switch A in OFF position Turn on the device If you know the actual IP address of the device you have to use this procedure Turn on the Device with the Ethernet cable inserted Insert the actual IP of the Converter Press the Ping button must appear Device Found Press the Next button Select which operations you want to do Press the Execute
2. Industrial Electronic Devices User Manual Revision 1 000 English EtherNet IP Modbus TCP Master Converter Order Code HD67664 A1 For Website information www adfweb com Product HD676064 For Price information www adfweb com Price HD67664 A1 Benefits and Main Features Very easy to configure Electrical isolation lt Two Ethernet ports for Modbus TCP EtherNet IP Temperature range 40 C 85 C 40 F 185 F User Manual ADFweb com S r l User Manual EtherNet IP Modbus TCP Master Document code MN67664 ENG Revision 1 000 Page 1 of 26 SHE i Bue FO ETHERS F weej EENET l E E egy For other EtherNet IP products see also the following link Converter EtherNet IP to www adfweb com Product HD67077 M Bus www adfweb com Product HD67595 CAN www adfweb com Product HD67597 DeviceNet Master www adfweb com Product HD67598 DeviceNet Slave www adfweb com Product HD67599 J1939 www adfweb com Product HD67589 NMEA 2000 www adfweb com Product HD67591 Modbus Master RS232 www adfweb com Product HD67591 Modbus Master RS485 www adfweb com Product HD67592 Modbus Slave RS232 www adfweb com Product HD67592 Modbus Slave RS485 Do you have your customer protocol Then go to www adfweb com Product HD67003 Do you need to choose a device Do you want help www adfweb com Cmd helpme iy User Manual EtherNet IP Modbus TCP Master Document code MN67664_ENG Revision 1 00
3. 0 Decimal SINT c HDB753 Decimal SINT c HDB753 0 Decimal SINT mHDS758 0 Decimal SINT mHHDE753 0 Decimal SINT xHDE 59 0 Decimal SINT c HDB753 Decimal SINT HD6759 0 Decimal SINT HD6759 D Decimal SINT HD6759 Decimal SINT HDE753 0 Decimal SINT x HDE 59 0 Decimal SINT mHDE 759 0 Decimal SINT c HDB753 0 Decimal SINT m HDE 53 o Decimal SINT HDE 53 0 Decimal SINT HD6758 0 Decimal SINT Hers o Decimal SINT m 4 gt Monitor Tags AgditTasf I n Add Branch ADFweb com S r l User Manual EtherNet IP Modbus TCP Master Document code MN67664 ENG Revision 1 000 Page 24 of 26 Industrial Electronic Devices M s RSLinx Classic Lite RSWho 1 BAX s5 File view Communications Station DDE OPC Security Window Help 8 5 With RSLinks Classic Lite after have done a network scan RSWho and finding the EtherNet IP device it is possible to load the EDS file for the device in order to have the Module Info compiled v Autobrowse Browsing node 192 168 1 20 found 3 Workstation FEDERICO 9 9 Wu Linx Gateways Ethernet ud 4 C s AB ETHIP 1 Ethernet 192 168 1 10 192 168 1 192 168 1 192 168 1 I 192 168 1 10 1769 L23E QB1 Ethernet Port 1769 L23E QB1 Ethernet Port 1769 L23bE HD67595 HD67590 HD67599 192 168 1 122 Unrecognized Device HD6759
4. FRUN No Forces Mo Edits t 5 E Controller ESEMPIO_B165 Tasks amp A MainTask 3 Unscheduled Programs B E Motion Groups _ 3 Ungrouped Axes E Add On Instructions S S Data Types 0 ER User Defined Cp Strings ER Add On Defined amp OB Predefined E Module Defined E Trends b 1 0 Configuration 5 CompactLogix5323E QB1 System fa 1769 L23E QB1 ESEMPIO B165 Gad 1769 L23E QB1 Ethernet Port LocalENB Sas a eg HIS J 2 1734 184 C input dig J 3 1734 1E2V C input an 4 1734 OE2V C output a fJ ETHERNET MODULE HD67599 9 CompactBus Local 5 6 Embedded 1 0 d 1 Embedded IQ16F Discrete Inpi B 2 Embedded OB16 Discrete Outr Expansion I O Create a module ADFweb com S r l Search Logic Communications Tools EH RU Path AB_ETHIP 1 192 168 1 10 Backplane O ES Window 4 MM RSLogix 5000 ESEMPIO B165 1769 L23E 0B1 19 11 Help Bex Az le Edt View Select a Language asua e c ZJ j y Am iYw aa Offline E RUN No Forces b No Edits ar un 1 H kan Fed Favorites 4H VE S Aur p x MOM Path AB_ETHIP 1 192 168 1 10 Backplane O q ae Timer aed EIS Controller Organizer 3 Controller ESEMPIO B165 amp amp 3 Tasks m Ea MainTask E Unscheduled Programs B E Motion Groups _ 9 Ungrouped Axes EI Add On Instructions amp 3 Data Types i User Defined
5. configuration assembly instance Therefore it is allowed to select an instance of 3 and to Module Properties LocalENB ETHERNET MODULE 1 1 General Connection Module Info Requested Packet Interval RPI 10 0 ms 1 0 3200 0 ms C Inhibit Module C Major Fault On Controller If Connection Fails While in Run Mode Use Unicast Connection over EtherNet IP Module Fault Status Running ADFweb com S r l User Manual EtherNet IP Modbus TCP Master Document code MN67664 ENG Revision 1 000 Page 23 of 26 Industrial Electronic Devices 4 After the configuration is completed the controller tags are created RSLogix 5000 ESEMPIO B165 1769 L23E QB1 19 11 Controller Tags ESEMPIO_B165 controller File Edit View Search Logic Communications Tools Window Help ox ae amp leoo v P3 Wr fe V amp amp amp pee Iv 9 CIEN Sa f No Forces gt W Controller OK E T A Battery OK No Edits W i 0 0K 4 LX dmn dS E oE EE XUE ER b g Controller Organizer SR scone ff ESEMPIO_B165 Show Al Tags v v vl S Controller ESEMPIO B165 T ad 3 Con Tags Name i zaf Value Force Mask e Style Data Type Description Constant Aill E B 3 Controller Fault Handler HD6758831 e Decimal SINT 500 m e _ 3 Power Up Handler HDE759 0 Decimal SINT 3 C
6. try to use in the main Operating System If you are using Windows Seven Vista and 8 make sure that you have the administrator privileges In case you have to program more than one device you have to cancel the ARP table every time you connect a new device on Ethernet For do this you have to launch the Command Prompt and write the command arp d Pay attention that with Windows Vista Seven 8 you have to launch the Command Prompt with Administrator Rights Pay attention at Firewall lock INIT PROTECTION Ver 1 002 FIRMWARE PROTECTION PROJECT PROTECTION Figure 8 Protection window In the case of HD67664 you have to use the software 5SW67664 www adfweb com download filefold SW67664 zip ADFweb com S r l User Manual EtherNet IP Modbus TCP Master Document code MN67664 ENG Revision 1 000 Page 19 of 26 Industrial Electronic Devices MECHANICAL DIMENSIONS V OV Power Supply LED Modbus TCP comm BAM AC o r D O LED Device State 12 35v DC EtherNet IP Modbus TCP Master Converter O LEDS Ethernet Tx i c d xe s c O LEE Ethernet Ts E vui ap 0 DE Sith 75 Ethern Date Code cs MAC 10 64 E2 07 30 73 47 14 B176 Serial Nr C1474 wWoHs e DE lt 120 mm i23 mm 4 72 inch 0 9 inch Housing PVC Weight 200g Approx Figure 7 Mechanical dimensions scheme for HD67664 A1 ADFweb com S r l User Manual Industrial Electronic Devices O
7. 0 Page 2 of 26 Industrial Electronic Devices ADFweb com S r l INDEX UPDATED DOCUMENTATION age Dear customer we thank you for your attention and we remind you that INDEX 2 you need to check that the following document is UPDATED DOCUMENTATION 2 REVISION LIST 2 Updated WARNING 2 Related to the product you own TRADEMARKS 2 SECURITY ALERT 3 To obtain the most recently updated document note the document code EXAMPLE OF CONNECTION A that appears at the top right hand corner of each page of this document CONNECTION SCHEME 5 CHARACTERISTICS 6 With this Document Code go to web page www adfweb com download CONFIGURATION 6 and search for the corresponding code on the page Click on the proper POWER SUPPLY 7 Document Code and download the updates FUNCTION MODES 8 LEDS 9 ETHERNET IP MODBUS TCP 10 REVISION LIST USE OF COMPOSITOR SW67664 11 NEW PROJECT OPEN PROJECT 12 Revision Date Author Chapter Description SOFTWARE OPTIONS 13 1 000 17 06 2014 Ff All First Release SET COMMUNICATION 14 SET ACCESS 15 UPDATE DEVICE 17 MECHANICAL DIMENSIONS 19 ORDERING INFORMATIONS 20 ACCESSORIES 20 WARNING PLC CONFIGURATION 21 DISCLAIMER 25 E OTHER REGULATIONS AND STANDARDS 25 ADFweb com reserves the right to change information in this manual about WARRANTIES AND TECHNICAL SUPPORT 26 AGE co COR ee ee for any error this manual may contain RETURN POLICY 26 P y y TRADEMARKS All trademarks mentio
8. 3 Tasks HDE S 0 Decimal SINT EIE e Sa MainTask HHDE758 0 Decimal SINT z M RET EHDE 753 ol Decimal SINT CI Unscheduled Programs 2 s A E Bi iilud per E Motion Groups HDE753 0 Decimal SINT E Ungrouped Axes HD67539 0 Decimal SINT Add On Instructions aos j ol Decimal SINT o mat S L Enoe o Decimal SINT d odi HDE753 0 Decimal SINT Cj Add On Defined m HDE753 0 Decimal SINT Predefined HD6753 0 Decimal SINT E Module Defined HD6759 0 Decimal SINT i is o NA HDE753 0 Decimal SINT 7 E E CompactLogix5323E QB1 System Bu SINT fa 1769 123 081 ESEMPIO_B165 HDES 0 Decimal SINT Ca 1769 L23E QB1 Ethernet Port LocalENB mi ct HD6758 0 Decimal SINT Cu Ethernet HD6759 0 Decimal SINT e 1769 L23E QB1 Ethernet Port Lace HD57583 0 Decimal SINT i i F T am ron 633 ch Her Dena SINT fj 0 1734 AENT A io vari HDB758 0 Decimal SINT fJ 1 1734 084 C output dic HD6 53 0 Decimal SINT 2 1734 IB4 C input dig mi HD6753 0 Decimal SINT 3 1734 1E2V C input an HD67539 o Decimal SINT D 4 1734 0E2V C output a HD6758 0 Decimal SINT B LR NAME erem HD6759 D Decimal SINT 3 Embedded IJO HDB7583 0 Decimal SINT B 1 Embedded IQ16F Discrete In HD67539 0 Decimal SINT 2 Embedded OB16 Discrete Outr HD6759 0 Decimal SINT E Expansion I O HD67539 0 Decimal SINT c HDB753
9. 5 77 Module Properties LocalENB ETHERNET MODULE 1 1 CS General Connection Module Info d 192 168 1 20 1734 AENT 192 168 1 189 HD67599 HD67599 R 192 168 1 20 1734 AENT EtherNet oe A f J Identification Status Driver Diagnostics Configure Driver Upload EDS file From device Security Device Properties Vendor Product Type Product Code Revision Serial Number Major Fault Minor Fault Internal State Configured Owned Product Name NUM 12 12 12 03 30PM SI Before adii Module Identity For Help press F1 Reset Module Status Offline Apo Identification Status Vendor Major Fault None Product Type Communications Adapter Minor Fault None Product Code 599 Unknown Internal State 1680055 unknown Revision 1 1 Configured Yes Serial Number E2071B24 Owned Yes Product Name HD67599 Module Identity Mismatch Status Running ADFweb com S r l User Manual EtherNet IP Modbus TCP Master Document code MN67664 ENG Revision 1 000 Page 25 of 26 Industrial Electronic Devices DISCLAIMER All technical content within this document can be modified without notice The content of the document is a under continual renewal For losses due to fire earthquake third party access or other accidents or intentional or accidental abuse misuse or use under abnormal conditions repairs are cha
10. RDERING INFORMATIONS The ordering part number is formed by a valid combination of the following HD67664 A1 L Connectors Type 1 Removable 5mm Screw Terminal Enclosure Type A 1M 35mm DIN Rail mounting Device Family HD67664 EtherNet IP Modbus TCP Master Converter Order Code HD67664 A1 EtherNet IP Modbus TCP Master Converter ACCESSORIES Order Code AC34001 35mm Rail DIN Power Supply 220 240V AC 50 60Hz 12V AC Order Code AC34002 35mm Rail DIN Power Supply 110V AC 50 60Hz 12 V AC ADFweb com S r l EtherNet IP Modbus TCP Master Document code MN67664 ENG Revision 1 000 Page 20 of 26 PLC CONFIGURATION Industrial Electronic Devices ia User Manual Document code MN67664 ENG EtherNet IP Modbus TCP Master Revision 1 000 Page 21 of 26 5 The configuration and commissioning of the EtherNet IP Converter as described on the following pages was accomplished with the help of the RSLogix 5000 software of Rockwell Automation In case of using a control system from another supplier please attend to the associated documentation These are the steps to follow Cre QUO ate a Sue MPIO B DE Generic Ethernet Module File Edit View Search Logic Communications Tools Window Help under the Ethernet section in the I O Configuration tree ag amp 5 BE v om Iv amp aR Gh fi Ei y Q Q Select a Language DEJ Offline fl
11. e Time ms the delay between two requests is defined Figure 3 Set Communication window ADFweb com S r l Industrial Electronic Devices SET MODBUS ACCESS By Pressing the Set Modbus Access button from the main window for SW67664 Fig 2 the window Set Access appears Fig 4 The window is divided in two parts the Modbus Read that contains the Modbus registers status readable by the Converter and Modbus Write that contains the Modbus registers status writeable by the Converter The meaning of the fields in the window are the follows In the field Slave IP Address the address of the Modbus device you have to read write is defined In the field Port the port used for require the Modbus data is defined In the field Slave ID is possible to insert the ID the address of the Modbus device you have to read write In the field Type insert the data type of the Register you would like to read write You can choose between the following o Coil Status R W o Input Status R o Holding Register R W o Input Register R ia User Manual EtherNet IP Modbus TCP Master Document code MN67664_ENG Revision 1 000 Page 15 of 26 SW67664 Set Modbus Access Modbus Read Modbus Write 1 aee E Akkea Port Se D Te EN ean a aae n aa RETLALT mn Fem 192 168 0 11 502 i Holding Register 100 1 ma M mt ame S00 0 4 3 us 192 168 0 11 502 li Co
12. en Bradley Allen Bradley Allen Bradley Allen Bradley Allen Bradley Allen Bradley Allen Bradley len Bra Ey Parker Hannif Add Favorite Industrial Electronic Devices Vendor Allen Bradley Parent LocalENB Name HD67599 Assembly Description Instance Size Comm Format Data SINT x m ee iw Configuration 3 0 S B8 bit Address Host Name Host Name ost Name set the value to zero Open Module Properties 3 The setting of 10msec for the Requested Packet Interval RPI is adequate but it is possible to change this value as required A lower value of 2ms shall not be selected Warning A The field Use Unicast Connection over EtherNet IP must be checked User Manual EtherNet IP Modbus TCP Master Document code MN67664 ENG Revision 1 000 Page 22 of 26 Mew Module 2 Edit the settings of the new Generic Ethernet Module As shown in the screen shot Type SE ANETEMIG GLE Eee Elie er cade below the module was named HD67664 and the IP address assigned is 192 168 0 5 Connection Parameters For the Comm Format Data SINT shall be selected as the data type Input 101 500 Sbit The HD67664 A1 can uses up to 496 bytes for input assembly instance 101 and 496 Output 100 500 eit bytes for output assembly instance 100 GiPAddes 192 188 0 5 RSLogix 5000 requires a configuration assembly instance Both modules do not provide a
13. il Status 200 10 5W6 6064 Set Modbus Access Modbus Read Modbus Write 192 168 0 11 302 1 2 192 168 0 11 502 1 3 192 168 0 12 502 2 Holding Register 100 Holding Register 123 Coil Status 200 Figure 4 Set Access windows In the field Address the start address of the register status to read write is defined In the field NPoint insert the number of consecutive registers status to read write ADFweb com S r l User Manual EtherNet IP Modbus TCP Master Document code MN67664 ENG Revision 1 000 Page 16 of 26 Industrial Electronic Devices In the field Poll Time insert the time expressed in milliseconds used for read write the register status If zero the request isn t made By checking the field On Change the Modbus write request is made only if EtherNet IP data are changed otherwise is sent cyclically using the Poll Time This feature is used only on Modbus Write section In the field Max Error insert the number of consecutive errors that the Master waits before discard the row from the cycle of requests In the field Position is possible to select the position where take save the data from EtherNet IP array The field Start Bit is used for select from which Bit save the data to use only when the Type is Coil Status or Input Status and the NPoint is more than one In the field Mnemonic is possible to insert a description of the data inserted in the row
14. ing the SW67664 the window below appears Fig 2 Note It is necessary to have installed Net Framework 4 SW6 7 7664 EtherNet IP Modbus TCP Master Converter Opened Configuration of the Converter Begin Example1 Step 1 E New Configuration Open Configuration Step 2 gt Set Communication Step 3 E set Access Step 4 3 Update Device www ADFweb com Figure 2 Main window for SW67664 ADFweb com S r l ia Industrial Electronic Devices M User Manual EtherNet IP Modbus TCP Master Document code MN67664 ENG Revision 1 000 Page 12 of 26 NEW CONFIGURATION OPEN CONFIGURATION The New Configuration button creates the folder which contains the entire device s configuration 5W6 664 Create New Configuration Name of the new Configuration A device s configuration can also be imported or exported To clone the configurations of a Programmable EtherNet IP Modbus TCP Master Converter in order to configure another device in the same manner it is necessary to maintain the folder and all its contents To clone a project in order to obtain a different version of the project it is sufficient to duplicate the project folder with another name and open the new folder with the button Open Configuration ADFweb com S r l 5W6 6064 Open an Existing Configuration List of Avaliable Configurations Examplel Example ia User Manual EtherNet IP Modbus TCP Mas
15. ion of the Dip2 of Dip Switch A The first with Dip2 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip2 of Dip Switch A at ON position is used for uploading the Project and or Firmware For the operations to follow for the updating see UPDATE DEVICE section According to the functioning mode the LEDs will have specific functions see LEDS section Dip Switch A Dip1 Must be at ON Dip2 Functioning Mode l hs Normal n H n Warning Dip1 of Dip Switch A must be at ON position to work even if the Ethernet cable is not inserted ADFweb com S r l Industrial Electronic Devices LEDS User Manual EtherNet IP Modbus TCP Master Document code MN67664 ENG The device has got four LEDs that are used to give information about the functioning status The various meanings of the LEDs are described in the table below LED Normal Mode 1 Modbus TCP comm Blinks when receive a correct green Modbus TCP response from a slave 1 Device State green Blinks slowly 1Hz Blinks when transmits a frame in 3 Ethernet1 Link green Ethernet Blinks when transmits a frame in 4 Ethernet2 Link green Ethernet Boot Mode Blinks quickly Boot state Blinks very slowly 0 5Hz Blinks quickly Boot state Blinks very slowly 0 5Hz Blinks quickly Boot state Blinks very slowly 0 5Hz Blink
16. ned in this document belong to their respective owners iy User Manual EtherNet IP Modbus TCP Master Document code MN67664_ENG Revision 1 000 Page 3 of 26 Industrial Electronic Devices SECURITY ALERT GENERAL INFORMATION To ensure safe operation the device must be operated according to the instructions in the manual When using the device legal and safety regulation are required for each individual application The same applies also when using accessories INTENDED USE Machines and systems must be designed so the faulty conditions do not lead to a dangerous situation for the operator i e independent limit switches mechanical interlocks etc QUALIFIED PERSONNEL The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operation of this equipment and who have appropriate qualifications for their job RESIDUAL RISKS The device is state of the art and is safe The instruments can represent a potential hazard if they are inappropriately installed and operated by untrained personnel These instructions refer to residual risks with the following symbol This symbol indicates that non observance of the safety instructions is a danger for people that could lead to serious injury or A death and or the possibility of damage CE CONFORMITY The declaration is made by our company You can
17. of the fields for EtherNet IP are In the fields IP ADDRESS insert the IP address that you want to give to the Converter EtherNet IP side _ GATEWAY In the fields SUBNET Mask insert the SubNet Mask cai In the fields GATEWAY insert the default gateway that you want to use This feature can Port be enabled or disabled pressing the Check Box field This feature is used for going out of the net Number Byte IN 500 In the field Port the port used for EtherNet IP communication is defined The port has a Number Byte Qut 500 fixed value of 44818 In the fields Number Byte IN insert the number of input byte of the slave station Modbus TCP Master Inthe fields Number Byte Out insert the number of output byte of the slave station IP ADDRESS 192 163 The means of the fields for the Modbus TCP Master section are SUBNET Mask In the fields IP ADDRESS insert the IP address that you want to give to the Converter 255 255 Modbus TCP side In the fields SUBNET Mask insert the SubNet Mask LIE 192 168 In the fields GATEWAY insert the default gateway that you want to use This feature can B ne or disabled pressing the Check Box field This feature is used for going out of the MIO e m net In the TimeOut ms define the maximum time that the device attends for the answer Communication Idle Time ms 100 from the slave interrogated Inthe field Communication Idl
18. rged to the user ADFweb com S r l will not be liable for accidental loss of use or inability to use this product such as loss of business income ADFweb com S r l shall not be liable for consequences of improper use OTHER REGULATIONS AND STANDARDS WEEE INFORMATION Disposal of old electrical and electronic equipment as in the European Union and other European countries with separate ps collection systems m his symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the recycling of electrical and electronic equipment If the product is disposed correctly you will help prevent potential negative environmental factors and impact of human health which could otherwise be caused by inappropriate disposal The recycling of materials will help to conserve natural resources For more information about recycling this product please contact your local city office your household waste disposal service or the shop where you purchased the product RESTRICTION OF HAZARDOUS SUBSTANCES DIRECTIVE The device respects the 2002 95 EC Directive on the restriction of the use of certain hazardous substances in electrical OHS and electronic equipment commonly referred to as Restriction of Hazardous Substances Directive or ROHS 2002 95 EC CE MARKING C The product conforms with the essential requirements of the applicable EC directi
19. s quickly Boot state Blinks very slowly 0 5Hz ADFweb com S r l update in progress update in progress update in progress update in progress Revision 1 000 Page 9 of 26 User Manual EtherNet IP Modbus TCP Master Document code MN67664 ENG Revision 1 000 Page 10 of 26 Industrial Electronic Devices ETHERNET IP MODBUS TCP The EtherNet IP and Modbus TCP connection must be made using Connector3 and or Connector4 of HD67664 A1 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T568 norms relative to connections in cat 5 up to 100 Mbps To connect the device to a Hub Switch the use of a straight cable is recommended To connect the device to a PC PLC other the use of a cross cable is recommended Connector2 Connectors Etherneti port RJ45 Plug m eS i 1 Ethernet2 port RJ45 Plug ADFweb com S r l User Manual EtherNet IP Modbus TCP Master Document code MN67664 ENG Revision 1 000 Page 11 of 26 Industrial Electronic Devices M USE OF COMPOSITOR SW67664 To configure the Converter use the available software that runs with Windows called SW67664 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last version of the software present on our web site The software works with MSWindows XP Vista Seven 8 32 64bit When launch
20. send an email to support adfweb com or give us a call if you need it ADFweb com S r l User Manual EtherNet IP Modbus TCP Master Document code MN67664 ENG Revision 1 000 Page 4 of 26 Industrial Electronic Devices EXAMPLE OF CONNECTION Ethernet IP network Modbus TCP network n oo 06 HD67664 A1 Modbus TCP Slaves ADFweb com S r l Industrial Electronic Devices M User Manual Document code MN67664 ENG EtherNet IP Modbus TCP Master Revision 1 000 Page 5 of 26 CONNECTION SCHEME Dip Switch A Dipi Must be at ON Dip2 Functioning Mode g Normal I8 TEHHHHHHTIII a V OV Power Supply CLEDI Hodbus TOP comm Ba 24V AC n mor EtherNet IP Modbus TCP Master Converter b HD67664 A1 E LED Ethernett Tx zi Ethernet vw ADF web com Q n M O LED Gtheamet Tk Dip Switch A C Ethernet Date Code cs MAC 10 64 E2 07 30 73 K 47 14 B176 Serial Nr C1474 oHS gt 3 Figure 1 Connection scheme for HD67664 A1 ADFweb com S r l Rail DIN Clamp Connectori Power Supply port OV Ground V Positive wire V AC min 8V max 24V DC min 12V max 35V User Manual EtherNet IP Modbus TCP Master Document code MN67664 ENG Revision 1 000 Page 6 of 26 Industrial Electronic Devices CHARACTERISTICS The HD67664 A1 is a EtherNet IP Modbus TCP Master Converter It allows for the following characteristics Up to 500 b
21. t Ep Strings E Add On Defined ee CR Predefined t C Module Defined E Trends 5 6 1 0 Configuration a B CompactLogix5323E QB1 System i hal 1769 L23E QB1 ESEMPIO B165 1769 L23E QB1 Ethernet Port LocalENB c wm Ethernet P e 1769 L23E QB1 Ethernet Port Loca S 1734 AENT A io vari B PointIO 5 Slot Chassis O 0 1734 AENT A io vari D 1 1734 084 C output dic D 2 1734 184 C input dig f 3 1734 1E2V C input an 4 1734 0E2V C output 3j ETHERNET MODULE HD67599 Efl CompactBus Local 5 6 Embedded I O be g 1 Embedded IQ16F Discrete_Inp S 2 Embedded 0816 Discrete_Outp EI Expansion I O 1783 EMS08T 1783 ETAP 1783 ETAP1F 1783 ETAP2F 1788 EN2DN A 1788 ENBT A 1788 EWEB A 1794 AEMT Drivelogix5730 Et ETHERNET BRIDGE EtherNet PSSCENA 1783 EMS08T Ethernet Managed Switch 3 Port Ethernet Tap Twisted Pair Media 3 Port Ethernet Tap 1 Fiber 2 Twisted Pair Media 3 Port Ethernet Tap 2 Fiber 1 Twisted Pair Media 1788 Ethernet to DeviceNet Linking Device 1788 10 100 Mbps Ethernet Bridge Twisted Pair Media 1788 10 100 Mbps Ethernet Bridge w Enhanced Web Serv 1794 10 100 Mbps Ethernet Adapter Twisted Pair Media 10 100 Mbps Ethernet Port on DriveLogix5730 Generic EtherNet IP CIP Bridge Ethernet Adapter Twisted Pair Media By Category By Vendor Favorites A Allen Bradley Allen Bradley Allen Bradley All
22. ter Document code MN67664 ENG Revision 1 000 Page 13 of 26 Industrial Electronic Devices M SOFTWARE OPTIONS By pressing the Settings gt button there is the possibility to change the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software cGW67664 Software Options SW6 7 664 Software Options Enable Internet Connection Check Software Update at Start of Program Cherk Available Update In the section Connection Options it is possible to check if there are some updatings of the software compositor in ADFweb com website Checking the option Check Software Update at Start of Program the SW67664 check automatically if there are updatings when it is launched ADFweb com S r l Ir User Manual EtherNet IP Modbus TCP Master Document code MN67664 ENG Revision 1 000 Page 14 of 26 Industrial Electronic Devices SET COMMUNICATION This section define the fundamental communication parameters of two buses EtherNet IP and Modbus TCP SW6 664 Set Communication Setting By Pressing the Set Communication button from the main window for SW67664 Fig 2 the C EtherNet IP window Set Communication appears Fig 3 x The window is divided in two sections one for the EtherNet IP and the other for the Modbus TCP idem Master iis p SUB k The means
23. update firmware button to start the upload When all the operations are OK the device automatically goes at Normal Mode At this point the configuration firmware on the device is correctly update ADFweb com S r l it is possible to load the created Configuration into the SW6 7664 Update Firmware from Etherner UDP Insert the IP Address of HD67602 192 _ fass 2 E J 205 E Check the Connection the device SW6 7664 Update Firmware from Etherner UDP Update Device Options Firmware Read Firmware when finish Project Read Project when finish a Execute update firmware INIT Waiting Ver 1 002 FIRMWARE Waiting PROJECT Waiting Figure 5 Update device windows Industrial Electronic Devices K Note User Manual EtherNet IP Modbus TCP Master Document code MN67664_ENG Revision 1 000 Page 18 of 26 When you install a new version of the software if it is the first time it is better you do the update of the Firmware in the HD67664 device cA Note When you receive the device for the first time you also have to update the Firmware in the HD67664 device A Warning If Fig 6 appears when you try to do the Update try these points before seeking assistance Try to repeat the operations for the updating Try with another PC Try to restart the PC Check the LAN settings If you are using the program inside a Virtual Machine
24. ves ADFweb com S r l User Manual EtherNet IP Modbus TCP Master Document code MN67664 ENG Revision 1 000 Page 26 of 26 Industrial Electronic Devices WARRANTIES AND TECHNICAL SUPPORT For fast and easy technical support for your ADFweb com SRL products consult our internet support at www adfweb com Otherwise contact us at the address support adfweb com RETURN POLICY If while using your product you have any problem and you wish to exchange or repair it please do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product to the address provided with the PRN having prepaid the shipping costs shipment costs billed to us will not be accepted If the product is within the warranty of twelve months it will be repaired or exchanged and returned within three weeks If the product is no longer under warranty you will receive a repair estimate ADFweb com S r l Via Strada Nuova 17 IT 31010 Mareno di Piave TREVISO Italy Phone 39 0438 30 91 31 Fax 39 0438 49 20 99 www adfweb com ADFweb com S r l
25. ytes in reading and 500 bytes in writing Isolation between Modbus EtherNet IP Power Supply Two directional information between Modbus TCP bus and EtherNet IP bus Mountable on 35mm Rail DIN Wide power supply input range 8 24V AC or 12 35V DC Wide temperature range 40 C 85 C 40 F 185 F 4 4 CONFIGURATION You need Compositor SW67664 software on your PC in order to perform the following Define the parameters of EtherNet IP line Define the parameters of Modbus TCP line Define the data to Read in Modbus TCP and where to map these information in the EtherNet IP array Define the data to Write in Modbus TCP and where to take the information in the EtherNet IP array Update the device ADFweb com S r l User Manual EtherNet IP Modbus TCP Master Document code MN67664 ENG Revision 1 000 Page 7 of 26 Industrial Electronic Devices POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below Consumption at 24V DC Devie Consumption W VA Caution Do not reverse the polarity power V Positive wire E TT V AC min 8V max 24V OV V V DC min 12V max 35V HD67664 A1 ADFweb com S r l User Manual EtherNet IP Modbus TCP Master Document code MN67664 ENG Revision 1 000 Page 8 of 26 Industrial Electronic Devices FUNCTION MODES The device has got two function modes depending on the posit

Download Pdf Manuals

image

Related Search

Related Contents

FlexScan S2231W User`s Manual  Severin HA 2082    There - Wasp Barcode Technologies  VSX-1325-K VSX-1125-K  Valueline VLAP24200B50  Phantasm CS Designer  SIM - Faculdade FAMA  

Copyright © All rights reserved.
Failed to retrieve file