Home
User Manual - Austin Hughes
Contents
1. PS 2 Servers USB Servers ge En DG 100 DG 100S VGA PS 2 dongle VGA USB dongle m m SI CAT 5 6 cable VGA max 40 meters DG 100SD DVI USB dongle B To connect DVI D connector to the computer s video card To connect USB connector to the computer s USB port DG 100S VGA USB dongle B To connect DB 15 connector to the computer s video card To connect USB connector to the computer s USB port DG 100 VGA PS 2 dongle B To connect DB 15 connector to the computer s video card B To connect PS 2 keyboard connector to the computer s keyboard port To connect PS 2 mouse connector to the computer s mouse port UM CV 751 MUKVM Q215V3 P2 www austin hughes com lt 1 3 gt IP Remote 8 Local console connection Matrix Cat6 IP KVM Network device hub or router CAT 5 6 cable max 100m Remote Receiver USB console CAT 5 6 cable max 150m Q SS A A Local Remote USB Cat6 console Console 1 EY Y Y Y Y xXrrrrrrrr II TL 99999991 17 7 6 5 Network device hub or router CAT 5 6 cable max 100m UM CV 751 MUKVM Q215V3 P 3 www austin hughes com How to use a receiver to connect a remote console Matrix Cat6 IP KVM Receiver Local Computer Monitor Remote I O K B Mouse Local Remote
2. LLLLILLILLJILLILLLLIJ level 7 MU 3202 Slave KVM rrr level 8 AATA _ CMC 8 2 as 8ft Matrix KVM cascade cable UM CV 751 MUKVM Q215V3 P 8 www austin hughes com 1 7 Specifications Matrix Cat6 IP MU IP1613 MU IP1624 MU IP3213 MU IP3224 KVM Port Number of ports 16 or 32 Connector RJ 45 Connectivity DVI D VGA connector dongle up to 40 meters 132 feet via Cat6 Cat5 cable Local Console Monitor port DB15 pin VGA up to 1600 x 1200 Keyboard amp mouse port 2 x USB type connector for keyboard amp mouse Cat6 Remote Console Number of remote port 1 Monitor port DB15 pin VGA up to 1600 x 1200 Keyboard amp mouse port 2 x USB type connector for keyboard amp mouse Remote 1 RJ45 via Cat5 Catbe Cat6 cable up to 500 feet IP Remote Console Number of IP console 1 for MU IP1613 MU IP3213 2 for MU IP1624 MU IP3224 User management 15 user login 1 x active user Browser Internet Explorer Firefox Safari Security SSL v3 RSA AES HTTP HTTPs CSR IP Access RJ45 Ethernet per IP console Expansion Up to 256 servers by 8 level cascade M Compatibility Multi platform Mix PCs SUN and Mac G4 Mac iMac Support Windows 7 Vista 2003 XP Linux Unix Power Input AC power adapter Consumption Max 48 Watt Standby 5 Watt Regulatory Safety
3. Cybe r View dedicated KVM switch and rackmount screen technology User Manual Matrix Cat6 KVM MU IP1613 1624 MU IP3213 3224 RoHS Matrix Cat6 KVM illl MU 1602 1603 1604 MU 3202 3203 3204 REACH 751 Designed and manufactured by Austin Hughes UM CV 751 MUKVM Q215V3 www austin hughes com Legal Information First English printing October 2002 Information in this document has been carefully checked for accuracy however no guarantee is given to the correctness of the contents The information in this document is subject to change without notice We are not liable for any injury or loss that results from the use of this equipment Safety Instructions Please read all of these instructions carefully before you use the device Save this manual for future reference Unplug equipment before cleaning Don t use liquid or spray detergent use a moist cloth B Keep equipment away from excessive humidity and heat Preferably keep it in an air conditioned environment with temperatures not exceeding 40 Celsius 104 Fahrenheit B When installing place the equipment on a sturdy level surface to prevent it from accidentally falling and causing damage to other equipment or injury to persons nearby When the equipment is in an open position do not cover block or in any way obstruct the gap between it and the power supply Proper air convection is necessary to
4. Copyright 2015 Austin Hughes Electronics Ltd All rights reserved UM CV 751 MUKVM Q215V3 www austin hughes com
5. with CMC 8 cascade cable A Cascaded KVMs from level 2 to 8 must be the models of MU 1602 MU 3202 or M 802 M 1602 When multiple matrix KVMs cascade together the master KVM at level 1 will take all control of other slave KVM switches e g level 2 to 8 The slave matrix KVM will be as a port expansion module of the master matrix KVM the original remote console on slave KVM will be sacrificed and disabled Master KVM 32 31 29 28 27 26 25 16 15 14 13 12 10 9 24 23 22 21 20 19 18 17 8 7 6 5 4 3 2 1 Cascade To cascade OUT port Slave KVM IGES level 2 FA MU 1602 11121112 MU 1602 Slave KVM 4 level 3 ULLLLILLIII Slave KVM level 4 22222222 Slave 2 MU 1602 level 5 MU 3202 Slave KVM UYYYYYYA level 6 LAA TAILS MU 3202 Slave KVM level 7 MU 3202 Slave KVM ee c YYYYYYWYYYTTYY iii THA Pu CMC 8 A 8ft Matrix KVM cascade cable UM CV 751 MUKVM Q215V3 P 16 www austin hughes com 2 5 Speci
6. CUL FCC amp CE certified Environment RoHS2 amp REACH compliant Environmental Operating 0 to 55 C Storage 5 to 60 C Relative humidity 90 non condensing Shock 50G peak acceleration 11ms half sine wave Vibration 58 100Hz 0 986 11ms cycle Product Information Dimension W x D x H 443 x 171 x 44 mm 17 4 x 6 7 x 1 73 inch Net weight 3kg 6 516 Packing Information Dimension W x D x H 500 x 400 x 90 mm 19 7 x 15 7 x 3 5 inch Gross weight 5kg 1116 UM CV 751 MUKVM Q215V3 P 9 www austin hughes com UM CV 751 MUKVM Q215V3 P 10 www austin hughes com Part 2 Matrix Cat6 KVM lt 2 1 gt Package Contents Matrix Cat6 KVM MU 1602 MU 3202 MU 1602 MU 3202 KVM unit x 1 Mounting set w bracket amp screws x 1 Power adapter w power cord for KVM x 1 Receiver box for remote console 1 Power adapter w power cord for receiver x 1 CE 6 6ft Combo KVM cable for receiver box x 1 MU 1603 MU 3203 MU 1603 or MU 3203 KVM unit x 1 Mounting set w bracket amp screws x 1 Power adapter w power cord for KVM x 1 Receiver box for remote console x 2 Power adapter w power cord for receiver x 2 CE 6 6ft Combo KVM cable for receiver box x2 MU 1604 MU 3204 MU 1604 or MU 3204 KVM unit x 1 Mounting set w bracket amp screws x 1 Power adapter w power cord for KVM x 1 Receiver box for remote console x 3 Power adapter w power cord for receiver x 3 CE 6 6ft Co
7. UM CV 751 MUKVM Q215V3 PAT www austin hughes com Part 3 Usage Matrix Cat6 KVM Usage 3 1 KVM Button Power ON Turn off all servers and KVM switches B Make sure all cables connectors are properly connected Recommend Power ON sequence is monitor switch finally computer Front Panel Port LED Indications 16 ports LILI 7157 AY JL Y Y Y Y Bank no PC port LEDs Channel button button Bank no 7 Segment BANK LED indication PC port LEDs Online Blue LED on indicating a PC is connecting to the port Active Green LED on indicating a selected channel Remote Orange LED on indicating the port is selecting by IP remote console Channel button Press to select channel from 01 to 32 Bank button Select the bank from 1 to 8 UM CV 751 MUKVM Q215V3 P 18 www austin hughes com 3 2 Password Matrix Cat6 KVM Usage The password is enabled by default the default password is 00000000 eight zeros Do not use 0 on number pad B Enable password 1 Press the KVM hotkey Scroll Lock Scroll Lock U 2 Logout the KVM by pressing the hotkey Scroll Lock Scroll Lock P 3 In SUPERVISOR level enter 00000000 eight zeros in user name amp password field Do not use 0 on number pad 4 n USER level press Space bar Enter in user name amp password field Remark Automatic logout after 10 minutes of inactivity B Set your own user name amp password 1 Login the KVM in SUPERVISOR level by pressin
8. Button Button to KVM switch A The receiver provides a hotkey function for remote console Please refer to P 19 BD in m FIYTYTTI o Remote Console 4 E o mc uoo Local computer Optional setup KVM cable Cat6 cable up to 150m 12V DC Power Adapter p UM CV 751 MUKVM Q215V3 PA www austin hughes com 1 4 gt IP console setting Matrix Cat6 IP KVM After the cable connection please take the following steps to configure the IP KVM 1 Download IPKVMsetup exe from the link www austin hughes com support utilities cyberview IPKVMsetup exe 2 SW 12 13 14 Open Internet Explorer I E version 6 0 or above Enter the IP KVM address into the address bar Double click IPKVMsetup exe to configure the IP KVM by device setup as below Device Setup Device Network Configuration Device MAC address C8 EE 08 00 00 7E IP auto configuration None Refresh Devices IP address 192 168 1 22 Device Type Subnet mask 255 255 255 0 C Enable WLAN Configuration WLAN Devices only Gateway 0 0 0 0 Authentication Wireless LAN Configuration EM Super user login oe 4 Super user password Enable WEP encryption 1 S New super user password New password confirm Status Ready Click
9. Refresh Device to search the connected IP KVM Select the M A C address which you want to setup then click Query Device Enter Super user login The default is super Enter Super user password The default is pass Enter the new super user password Re enter the new password Change the desired IP address Subnet mask Gateway then click Setup Device to confirm the setting to IP KVM The default address is as below The single KVM model such as MU IP3213 http 192 168 1 22 The dual IP KVM model such as MU IP3224 http 192 168 1 22 for 1st IP http 192 168 1 23 for 2nd IP Authenticate Username and Password For Single IP http 192 168 1 22 ForDuallP http 192 168 1 22 for 1st IP http 192 168 1 23 for 2nd IP Password Enter username default is super Password default is pass After successful login to IP KVM the user will enter the main page of IP KVM The setting is enough for intranet If the users access KVM GUI via internet please ask MIS for assistance and download IP KVM user manual from the link www austin hughes com support usermanual cyberview UM CV IP pdf UM CV 751 MUKVM Q215V3 P5 www austin hughes com 1 5 Important Preconfiguration for IP console Matrix Cat6 IP KVM A You must complete the following tasks after the IP console setting is performed 1 TARGET SERVER SETUP Servers connected to KVM Resolution Th
10. amage of the product due to shipment Removal or installation of the product Causes external to the product such as electric power fluctuation or failure Use of supplies or parts not meeting our specifications Normal wear and tear Any other causes which does not relate to a product defect B Removal installation and set up service charges Regulatory Notices Federal Communications Commission This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation Any changes or modifications made to this equipment may void the user s authority to operate this equipment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Re position or relocate the receiving antenna B Increase the separation between the equipment and receiver B Connect the equipment into an out
11. ank 2 Port 16 Scroll Lock Scroll Lock 2 1 6 You must press the hotkey within 2 seconds A beep sound will be heard for successful entering The numeric keypad is not supported while in OSD screen the arrow keys PgUp PgDn and Enter keys are supports Remote Console Hotkey Function Scroll Lock Scroll Lock C Toggle switch between remote amp local port Scroll Lock Scroll Lock Q Turn the buzzer ON amp OFF Default the buzzer is ON Scroll Lock Scroll Lock S Activate auto scan mode for remote amp local port The scan time interval is 5 seconds Scroll Lock Scroll Lock A Auto adjust the video signal UM CV 751 MUKVM Q215V3 P21 www austin hughes com 3 5 Resolution Support Information Matrix Cat6 KVM Usage IP Console Remote Console Resolution Frequency Hz Resolution Frequency Hz 1600 x 1200 600 1600 x 1200 1024 x 768 60 70 75 1024 x 768 60 70 75 800 x 600 60 72 75 800 x 600 60 72 75 640 x 480 60 72 75 640 x 480 60 72 75 Cat6 KVM VGA DVI Dongle DG 100S DG 100 DG 100SD Resolution Frequency Hz 1024 x 768 60 70 75 800 x 600 60 72 75 640 x 480 60 72 75 UM CV 751 MUKVM Q215V3 P 22 www austin hughes com The company reserves the right to modify product specifications without prior notice and assumes no responsibility for any error which may appear in this publication All brand names logo and registered trademarks are properties of their respective owners
12. e IP KVM remote console recognizes several varieties of video display formats with resolutions up to 1600 x 1200 60Hz Refer to the User Manual for a list of supported video formats Minimize bandwidth by setting the target server s video resolution to the minimum setting required for your remote monitoring application The following video modes are recommended i 800 600 60Hz ii 1024 x 768 60Hz iii 1280 x 1024 60Hz On a Windows target server system select Control Panel gt Display gt Settings Modify the screen resolution value as necessary Mouse Use generic mouse drivers for optimum mouse control during remote sessions Set the mouse pointer speed to a middle setting with no acceleration or snap to effects On a Windows target server system select Control Panel gt Mouse gt Pointer Options Set the pointer speed to medium and disable Enhanced pointer precision For Linux GUls set the mouse acceleration to exactly 1 and the threshold to exactly 1 A If your keyboard keeps repeating keys when it is plugged into the KVM Please follow either one below a Enable key release timeout if you experience duplicated keystrokes during poor network performance login to IP KVM remote console goto Interfaces KVM settings gt Keyboard Mouse click the Key Release Timeout adjust Timeout after if necessary b Reduce video bandwidth usage if you experience duplicated keystrokes during poor network logi
13. e supplier immediately Installation for standalone KVM Screw A 2 pcs Screw B 8 pcs e M3 2 x 4 5 mm M4 10 mm E Install each bracket using screws provided shown in Figure 1 B Fixthe KVM into the rack Figure 1 UM CV 751 MUKVM Q215V3 www austin hughes com Part 1 Matrix Cat6 KVM lt 1 1 gt Package Contents Matrix Cat6 IP KVM MU IP1613 MU IP3213 MU IP1624 MU IP3224 MU IP1613 or MU IP3213 or MU IP1624 or MU IP3224 KVM unit x 1 Mounting set w bracket amp screws x 1 Power adapter w power cord for KVM x1 Receiver box for remote console 1 Power adapter w power cord for receiver x 1 CE 6 6ft Combo KVM cable for receiver box x 1 MU IP1613 Local Console Remote Console 1 MU IP3213 10 g Pd out in 16 15 14 13 12 10 ol d d i 24 2 Local Console Remote Console 1 MU IP1624 o lai POP 9 m Cascade MU IP3224 i CYYYYYYS 24 23 22 21 20 19 18 8 7 6 5 4 3 2 1 UM CV 751 MUKVM Q215V3 PA www austin hughes com 1 2 KVM port amp Cat6 dongle connection Matrix Cat6 IP KVM USB Servers DG 100SD DVI USB dongle CAT 5 6 cable m max 40 meters 000 Cat6 KVM port
14. fications Matrix Cat6 KVM MU 1602 MU 1603 MU 1604 MU 3202 MU 3203 MU 3204 KVM Port Number of ports 16 or 32 Connector RJ 45 Connectivity DVI D VGA connector dongle up to 40 meters 132 feet via Cat6 Cat5 cable W Local Console Monitor port 1 DB15 pin VGA up to 1600 1200 Keyboard amp mouse port 2 x USB type connector for keyboard amp mouse Cat6 Remote Console Number of remote port 1 for MU 1602 MU 3202 2 for MU 1603 MU 3203 3 for MU 1604 MU 3204 Monitor port DB15 pin VGA up to 1600 x 1200 Keyboard amp mouse port 2 x USB type connector for keyboard amp mouse Remote 1 RJ45 via Cat5 Cat6 cable up to 500 feet Expansion Up to 256 servers by 8 level cascade W Compatibility Multi platform Mix PCs SUN and Mac G4 Mac iMac Support Windows 7 Vista 2003 XP Linux Unix W Power Input AC power adapter Consumption Max 48 Watt Standby 5 Watt Regulatory Safety CUL FCC amp CE certified Environment RoHS2 amp REACH compliant Environmental Operating 0 to 55 C Storage 5 to 60 C Relative humidity 90 non condensing Shock 50G peak acceleration 11ms half sine wave Vibration 58 100Hz 0 986 11ms cycle Product Information Dimension W x D x H 443 x 171 x 44 mm 17 4 x 6 7 x 1 73 inch Net weight 3kg 6 516 E Packing Information Dimension W x D x H 500 x 400 x 90 mm 19 7 x 15 7 x 3 5 inch Gross weight 5kg 1116
15. g 00000000 eight zeros in user name amp password field Call KVM OSD menu by pressing the KVM hotkey Scroll Lock Scroll Lock Space Bar Press F1 to the MAIN MENU Select USER SECURITY Set password in SUPERVISOR amp USER level a In the left top row S SUPERVISOR press Enter to set your own user name amp password b In the row 1 to 8 USER press Enter to set your own user name amp password 6 Press Enter to save the setting or press Esc to cancel the editing without any change d co N Remark a Blank has underscore while SPACE doesn t have b Press any alphanumeric key to move to next input item SPACE is treated as a valid character B Change your password Login the KVM in SUPERVISOR level by pressing your own user name amp password Call KVM OSD menu by pressing the KVM hotkey Scroll Lock Scroll Lock Space Bar Press F1 to the MAIN MENU Select USER SECURITY Change password in SUPERVISOR amp USER level a In the left top row S SUPERVISOR press Enter to change your user name amp password b In the row 1 to 8 USER press Enter to change your user name amp password 6 Press Enter to save the setting or press Esc to cancel the editing without any change Remark a Blank has underscore while SPACE doesn t have b Press any alphanumeric key to move to next input item SPACE is treated as a valid character B Disable your password 1 Press the KVM hotkey Scroll Lock Scroll Lock U 2 Log
16. ge hotkey TIME SETTINGS Modify scan display time interval OSD MOUSE Modify OSD mouse speed UM CV 751 MUKVM Q215V3 P 20 www austin hughes com 3 4 KVM Hotkey amp Remote Console Hotkey Matrix Cat6 KVM Usage Local Console Hotkey Function Scroll Lock Scroll Lock Space Bar Calling OSD menu Right button mouse Esc Calling OSD menu Scroll Lock Scroll Lock 4 Switch to previous port Scroll Lock Scroll Lock 98 Switch to next port Scroll Lock Scroll Lock PgUp PgDn Switch to previous bank or next bank Scroll Lock Scroll Lock Bank Port no Switch to specific port Turn the buzzer ON and OFF Default the buzzer is ON Logout the KVM if password security is ON Show up the status windows Scroll Lock Scroll Lock B Scroll Lock Scroll Lock P Advance hotkeys for Supervisor login only Activate auto scan mode for connected servers Press any key to exit the auto scan mode Reset all the KVM settings to factory Scroll Lock Scroll Lock default Except User Security settings Disable and enable password security Default security is ON To enable disable the screen saving Scroll Lock Scroll Lock function and 10 minutes auto logout Default the screen saving is OFF Scroll Lock Scroll Lock Scroll Lock Scroll Lock Remarks B Example of Scroll Lock Scroll Lock Bank no Port no Bank No 1t08 Port No 01 to 16 e g Bank 1 Port4 Scroll Lock Scroll Lock 1 0 4 e g B
17. keep it from overheating Arrange the equipment s power cord in such a way that others won t trip or fall over it f you are using a power cord that didn t ship with the equipment ensure that it is rated for the voltage and current labeled on the equipment s electrical ratings label The voltage rating on the cord should be higher than the one listed on the equipments ratings label Observe all precautions and warnings attached to the equipment f you don t intend on using the equipment for a long time disconnect it from the power outlet to prevent being damaged by transient over voltage Keep all liquids away from the equipment to minimize the risk of accidental spillage Liquid spilled on to the power supply or on other hardware may cause damage fire or electrical shock B Only qualified service personnel should open the chassis Opening it yourself could damage the equipment and invalidate its warranty lf any part of the equipment becomes damaged or stops functioning have it checked by qualified service personnel What the warranty does not cover Any product on which the serial number has been defaced modified or removed Damage deterioration or malfunction resulting from O Accident misuse neglect fire water lightning or other acts of nature unauthorized product modification or failure to follow instructions supplied with the product Repair or attempted repair by anyone not authorized by us Any d
18. let on a circuit different from that to which the receiver is connected UM CV 751 MUKVM Q215V3 www austin hughes com Contents lt Part 1 gt Matrix Cat6 KVM 1 1 12 Tou 1 4 1 5 1 6 T lt Part 2 gt 2 1 2 2 2 3 2 4 2 5 MU IP1613 MU IP1624 MU IP3213 MU IP3224 Package contents KVM port amp Cat6 dongle connection IP Remote amp Local console connection IP console setting Important Preconfiguration for IP console KVM Cascade Specifications Matrix KVM MU 1602 MU 1603 MU 1604 MU 3202 MU 3203 MU 3204 Package contents KVM port amp 6 dongle connection Remote amp Local console connection KVM Cascade Specifications lt Part 3 gt Usage 3 1 3 2 3 3 3 4 3 5 KVM Button Password KVM OSD KVM Hotkey Remote Console Hotkey Resolution Support Information UM CV 751 MUKVM Q215V3 P2 P 3 4 P 5 P 6 7 P 8 P 9 P 11 12 P 13 P 14 15 P 16 7 18 19 20 21 22 www austin hughes com Before Installation itis very important to mount the equipment in a suitable cabinet or on a stable surface B Make sure the place has a good ventilation is out of direct sunlight away from sources of excessive dust dirt heat water moisture and vibration Unpacking The equipment comes with the standard parts shown in package content Check and make sure they are included and in good condition If anything is missing or damaged contact th
19. mbo KVM cable for receiver box x 3 UM CV 751 MUKVM Q215V3 P 11 www austin hughes com Matrix Cat6 KVM MU 1602 Local Console Remote Console 1 16 Power 83118243 MU 3202 MU 1603 Local Console Remote Console 1 CEET chio MI Remote 2 out in Cascade MU 3203 MU 1604 Remote 3 Local Console Remote Console 1 Cin ah T Y q raro De Remote 2 out in Cascade MU 3204 Y Y Y E Y Y Y EY X Y Y X3 LL A 4 A UM CV 751 MUKVM Q215V3 P 12 www austin hughes com 2 2 KVM port amp Cat6 dongle connection Matrix Cat6 KVM USB Servers DG 100SD DVI USB dongle CAT 5 6 cable mm Fy y max 40 meters o uoo 10000008 00 Cat6 KVM port PS 2 Servers USB Servers BDI DG 100 DG 100S VGA PS 2 dongle VGA USB dongle m m SI CAT 5 6 cable VGA max 40 meters Cc DG 100SD DVI USB dongle 1 B To connect DVI D connector to the computer s video card To connect USB connector to the computer s USB port oma uoo DG 100S VGA USB dongle B To connect DB 15 connector to the computer s video card To connect USB connector to the com
20. n to IP KVM remote console goto Interfaces KVM Settings gt User Console gt Transmission Encoding select Manually adjust Compression to 0 none and Color depth to 8 bit 256 col UM CV 751 MUKVM Q215V3 P 6 www austin hughes com 1 5 Important Preconfiguration for IP console Matrix Cat6 IP KVM 2 REMOTE CLIENT COMPUTER SETUP The remote client computer must have a web browser such as Microsoft Internet Explorer Mozilla Firefox and Netscape Navigator and a Java Virtual Machine version 1 4 or higher installed Enable Java on the web browser amp JAVA Security Issue Due to the changes from Java security customer may facing the JAVA Block message while accessing the remote console over IP Application Blocked by Java Security iei For security applications must now meet the requirements for the High or Very High security settings or be part of the Exception Site List to be allowed to run More Information Reason Your security settings have blocked a self signed application from running If it said so here is the workaround solution Customer can use the Exception Site list feature to run the applications blocked by security setting Adding the URL of the blocked application to the Exception Site list allows it to run with some warnings Steps to Add URLs to the Exception Site list Go to the Java Control Panel On Windows Click Start and then Configure Java Click on the Secu
21. out the KVM by pressing the KVM hotkey Scroll Lock Scroll Lock P 3 You don t need user name amp password to access the KVM OSD menu B Forget your password Please contact your supplier for further support Remark You must press the KVM hotkey within 2 seconds sound will be heard for successful entering KVM hotkey UM CV 751 MUKVM Q215V3 P 19 www austin hughes com 3 3 KVM OSD Matrix Cat6 KVM Usage OSD Menu PORT NAME BANK 1 F1 MENU 0135 BARNE F2 LOGOUT 02 SYSTEM 02 PREV 03 SYSTEM ESC QUIT 04Xt SYSTEM ENTER COMPLETE 05 SYSTEM 3 8 SELECT 06 SYSTEM PgUp PgDn 07 SYSTEM BANK SELECT 08 SYSTEM USER SUPERVISOR SCAN TIME 10 SEC OSD operation it next to the system name The PC is powered on next to the system name The PC is selected F1 Access F1 MAIN MENU F2 Logout the OSD menu F3 Previous menu Esc Cancel Quit Enter Complete Switch to selected port t t Switch to previous or next port PgUp PgDn Switch to previous bank or next bank Display port 01 08 09 16 17 24 25 32 1121314 Remark Display port 17 32 for 32 port model only F1 Main Menu MAIN MENU SELECT OPTION LANGUAGE PORT NAME EDIT PORT SEARCH USER SECURITY ACCESS LIST HOTKEY TIME SETTINGS OSD MOUSE LANGUAGE OSD language change PORT NAME EDIT Define port name PORT SEARCH Quick searching by port name USER SECURITY Change password ACCESS LIST Define user access authority HOTKEY Chan
22. puter s USB port DG 100 VGA PS 2 dongle B To connect DB 15 connector to the computer s video card B To connect PS 2 keyboard connector to the computer s keyboard port To connect PS 2 mouse connector to the computer s mouse port UM CV 751 MUKVM Q215V3 P 13 www austin hughes com lt 2 3 gt Local console 8 remote console connection Remote Cat6 Console 3 Remote Cat6 Console 2 Receiver CAT 5 6 cable max 150m Receiver CAT 5 6 cable max 150m e A Local Remote USB Cat6 console Console 1 Matrix Cat6 KVM Remote USB console 3 Remote USB console 1 Receiver CAT 5 6 cable max 150m UM CV 751 MUKVM Q215V3 P 14 Remote USB console 2 www austin hughes com How to use a receiver to connect a remote console Matrix Cat6 KVM Receiver Local Computer Monitor Remote I O Local Remote Button Button to KVM switch LoL m Ee BD Remote Console 4 Local computer Pani Cat6 cable Optional setup up to 150m KVM cable 81 EI 12V DC Power Adapter UM CV 751 MUKVM Q215V3 P 15 www austin hughes com lt 2 4 gt KVM Cascade Matrix Cat6 KVM B Cascade up to 8 levels 256 servers Cascading multiple
23. rity tab Click on the Edit Site List button Click Add in the Exception Site List window Click in the empty field under the Location field to enter the URL URL should begin with http or https i Java Security Advanced Appkcabors launched from the sites isted below will be slowed to run after the appropriate security prompts Enable Java content in the browser focali 192 168 1 22 Security level for appicatone not on the Excepton Site list Very High Only Java applications identified by a certificate from a trusted authority are allowed to run and only if the certificate can be verified as not revoked 9 High Java applications identified by a certificate from a trusted authority are alowed to Add Remove nun even if the revocation status of the certificate cannot be verified ilg FILE and HTTP protocols are considered a security risk We recommend using HTTPS sites where available Exception Site List Do you want to run this application Applications launched from the sites listed below mill be allowed to run after the appropriate security prompts htto 192 168 1 22 Publisher UNKNOWN Location http 192 160 1 22 Running this application may be a security risk Riske Medeae with unrestricted access which may put your computer and personal information at risk toler I a itis recommended not to run this application unless you are fem er with its
24. source More Information Select the box below then click Run to start the application AEREI UM CV 751 MUKVM Q215V3 7 www austin hughes com lt 1 6 gt KVM Cascade Matrix Cat6 IP KVM B Cascade up to 8 levels 256 servers Cascading multiple with CMC 8 cascade cable A Cascaded KVMs from level 2 to 8 must be the models of MU 1602 MU 3202 or M 802 M 1602 When multiple matrix KVMs cascade together the master KVM at level 1 will take all control of other slave KVM switches e g level 2 to 8 The slave matrix KVM will be as a port expansion module of the master matrix KVM the original remote console on slave KVM will be sacrificed and disabled Master KVM iit in Cascade To cascade OUT port Slave KVM 2 9 fa aaa aaa a level 2 Het MU 1602 MU 1602 Slave KVM level 3 MU 1602 slave KVM ES LILI LALLJ level 4 MU 1602 Slave KVM TETTETETT level 5 MU 3202 Slave KVM C ARTT 122271 level 6 OAR AAR MU 3202 Slave KVM
Download Pdf Manuals
Related Search
Related Contents
Oregon Scientific i.fresh WS907 User's Manual 集塵機 SDC‐Lシリーズ 取扱説明書 事 務・連 絡 - 全国老人保健施設協会 MANUAL DE INSTRUCCIONES TELÉFONO TEL-2953 Shure DFR22 User Guide M-Cab PCI-E/SATA II Card PREZZARIO REGIONALE DEI LAVORI PUBBLICI A l`attention du curateur en matière de curatelle simple réapprendre Copyright © All rights reserved.