Home
RAIN & MASSAGE SHOWER SPA
Contents
1. 3 from the wall using a wrench and turning it counter clockwise DO NOT DISCARD YET 3 3 GY Vo 0 cm Mark shower lt gt arm here Fig 11 Put teflon tape B on the end of the long brass connector E that has the white check valve D see Fig 12 Teflon tape on this end 2 3 16 55 6 mm B Nu D Fig 12 Put your old shower arm the one you have just removed on a flat surface Beside it put the long brass connector E with the teflon tape B and check valve D side aligned with the threaded side of the shower arm On the end of the long brass connector E the end that has the hexagonal hole inside add as needed the small brass connectors 28 mm 1 11 10 F threading them in place until the total length of the brass connector assembly is between 5 8 and 1 1 8 16 mm and 29 mm longer than the place where the mark was made on the shower arm Mark on shower arm This distance E This distance This distance This distance should be side should be should be should be between 5 8 Align here between 5 8 between 5 8 between 5 8 and 1 1 8 and 1 1 8 and 1 1 8 and 1 1 8 Fig 13 Using the provided Allen key A install the new assembled brass connector see Fig 14 making sure that the end where you placed the teflon tape where the check valve is goes towards the wall where the old shower arm was Clean the wall around the brass connector assembly throroughly with a dry
2. The handheld shower and the body jets COMBINED 6 The body jets and the shower head COMBINED Adjust water temperature and pressure using your existing shower valve Fig 32 Troubleshooting Make sure that the rubber washers N U are properly installed to prevent leaks Make sure that you drill holes according to the instructions and that you secure the shower column S with the double sided tape or on the bottom bracket If you find that water pressure or volume is low clean the mesh gasket C If there is no water flow check the brass connector E to make sure that it has not been installed incorrectly Refer to Fig 12 amp 13 on page 7 of the installation guide If the check valve D is installed correctly and there is still no water flow take the shower column 5 off the wall loosen the L fitting L and check that the restrictor K is not blocked by debris Take the restrictor off clean with water and reinstall Maintenance After use rinse the shower column with water using the handheld shower to remove any soap deposits Should water spots occur clean with a mild solution of vinegar and water followed by a thorough rinse Use liquid soap a general household cleaner or a weak solution of vinegar and water for regular cleaning Never use abrasive cleaners as they will scratch the finish 11 CONGLOMKB COM Please contact 1 877 333 0098 for further assistance Replacement Parts
3. If you are missing parts or if you require replacement parts please contact our customer service team at customer service conglomkb com or 1 877 333 0098 8 30 am 5 pm EST Monday Friday Identify the required part s and have the part number s ready ay 3 Stainless steel mounting bracket QHB115 mo oso _ Rubber washer 1 2 Top cover QHBi21 Stainless steorcover QHB122 _ ____________ _ Rubber washer 1 2 V Shower head Handheld shower head ioe Part c E F G EN K Ex a R ER 12 Imported by Conglom KITCHEN amp BATH St Laurent Quebec H4S 2C3 1 877 333 0098 www conglomkb com Made in China
4. KET AND SCREWS see page Tub spout Diverter Di 9 In both cases the weight of the unit is carried by the mounting verter bracket H The double sided tape or the bottom bracket BB prevent e __ the unit from swinging during operation w Ls SHOWER HEAD INSTALLATION Remove the top cover P and the stainless steel cover Q from the shower column S see Fig 3 Remove the nut R that is pre installed in the shower arm T see Fig 4 Aa gt uN P A Fig 3 S 0 Fig 4 z R Insert the shower arm T into the shower column S and secure it with the nut R see Fig 5 amp 6 Fig 5 Place the rubber washer N onto the L fitting M see Fig 7 Connect the L fitting M to the shower arm T see Fig 8 7 T 78 Fig 7 Fig 8 Check that the rubber washer U that is pre assembled on the shower head V is not loose see Fig 9 Screw the shower head V on E the shower arm T see Fig 10 gt 78 T amp Q T Fig 6 f R S Fig 10 Installation continued NOTE Make sure that your shower valve is closed at all times from now until the testing is required Disassemble your existing shower head 1 Pull away from the wall cover 2 that is in the area where the shower arm 3 meets the wall Mark clearly on your existing shower arm the level at which the wall meets the shower arm see Fig 11 Remove your existing shower arm
5. MULTIFUNCTION PRESENZA BAIN amp MASSAGE SHOWER SPA INSTALLATION GUIDE AND USER MANUAL Model No QB018 E AY Si A E S SS Zap reves gae Table of Contents Table of Contents 2 Installation Safety 2 Shower Head 6 Warranty Double Sided Tape Method 8 One Year Limited 3 Bottom Bracket 9 Warranty Claim 3 Shower Stall Uneven Surfaces 10 Pre Installation Adr mee 11 Tools Materials 4 Troubleshooting 11 Package Contents 5 Maintenance 11 Service Parts 12 Safety Information READ AND SAVE THESE INSTRUCTIONS A CAUTION Always wear safety goggles and gloves during 1 Inspect your unit before proceeding Once you unpack your unit installation to prevent personal injury check for chips scratches cracks dents or scuff marks If any damage is noticed do not install 2 Use this unit only in the manner intended by the manufacturer If you have any questions contact the manufacturer 3 Installation work and plumbing
6. cloth Peel the paper backing from the double sided tape on the stainless steel mounting bracket H see Fig 15 Q N 27 Assembled brass connector H Fig 14 7 Wall Fig 15 CONGLOMKB COM Please contact 1 877 333 0098 for further assistance Installation continued Place the stainless steel mounting bracket H on the brass connector assembly and adhere upright the wall see Fig 16 oe Ae Secure and tighten the nut J on brass assembly using one or 2 of H G J the stainless steel washers G if required see Fig 17 Bracket H allows for mounting this unit on flat walls or on walls that have a shower surround or tiles with a step of up to 1 1 2 38 mm Fig 16 Fig 17 OPTION A DOUBLE SIDED TAPE FOR FLAT WALLS SHOWER STALLS AND TILES WITH AN UNEVEN SURFACE OF UP TO 1 1 2 Connect L fitting L to brass connector assembly using restrictor Brass Connector K see Fig 18 Assembly KL With a dry rag thoroughly clean the wall between the brass connector and the shower valve B Peel the paper backing from the double sided tape on back of column see Fig 19 Fig 18 Fig 19 Mm Mm Hang the shower column S on the stainless steel mounting bracket H through holes in the column Position column vertically level H H then apply pressure to main body to firmly adhere mounting tape to 5 5 the wall see Fig 20 With flat wall With stalls or tiles with an uneven surfac
7. e of up to 1 1 2 38 mm Fig 20 Installation continued OPTION B BOTTOM BRACKET AND SCREWS FOR FLAT WALLS ONLY Mark the drill holes 1 4 0 635 cm see Fig 21 The three holes consist of two holes drilled side by side 0 67 1 7 cm apart from the center of each hole with the center line running between them The third hole is drilled on the center line 0 79 2 cm below the first two holes The upper two holes should be drilled below the shower pipe 22 1 4 b6 5 cm from the center of the top two holes to the center of the inlet pipe Insert wall anchors AA in pre drilled holes Secure bottom bracket BB to the wall with screws and stainless steel washers CC see Fig 22 Connect L fitting L to brass connector assembly using restrictor K see Fig 23 Hang the bottom of the shower column S on the bottom bracket BB first then hand the shower column S on the stainless steel mounting bracket H through the holes in the shower column see Fig 24 Fig 23 0 67 1 7 cm 0 0 79 2 Fig 21 inlet 3 o LO O I x N 0 67 1 7 9 7J 0 79 2 cm AA BB CC Fig 22 H 4 S BB Fig 24 CONGLOMKB COM Please contact 1 877 333 0098 for further assistance Installation continued FINAL INSTALLATION Replace top cover P and the stainless cover Q on the shower P gt 1 column S see Fig 25 Attach long flexible shower hose Y t
8. goggles Pre Installation continued PACKAGE CONTENTS Part Descripton ay Part Description Pan Descriion CA Atentey ___ u u c 1 P Top covertpre instatea 1 Aa Wallanchors _ 3 s Teton tape _ 1 Stainess steet cover pre instated BB Bottom bracket 1 re i R w _ _ _ _ o Check valve pre instated 1 5 Sowercoumn 1 00 Aluminum plate cover 2 E Long brass connector 5mm 1 T sSwram 1 LV Rubber washer 2 ES e stainless stool washers 2 v Stowernead stainless steel mounting bracket 1 w Handheld showerhead ct _______ x oeckave prestato 1 rk restrictor 1 2 bracket pre instateg 17 1 Uoperbodyjet 1 Cw Rubber wasner 2 2 2 CONGLOMKB COM Please contact 1 877 333 0098 for further assistance Installation This unit is designed to be installed using your existing ae par plumbing Your shower valve diverter valve or diverter tub Existing US shower Y spout will be used in its current position and will operate as before see Fig 2 NOTE Existing This unit can either be installed with OPTION A DOUBLE SIDED TAPE ioco pda see page 8 or OPTION B BOTTOM BRAC
9. must be done by qualified person s in accordance with all applicable codes and standards 4 Protect the entire surface during installation BEFORE YOU BEGIN EE EES 1 Installs on both flat and uneven surfaces of up to 1 1 2 38 mm see Fig 1 2 This unit might not be suitable for installation with some Cort fiberglass or acrylic showers 3 This product will connect with your current shower valve There is no need to take out your current valve or change it LTT TI Flat mounting surface Uneven mounting surface Fig 1 Warranty ONE YEAR LIMITED WARRANTY Athorough inspection must be made before installation and any damage must be promptly reported We will not be liable for failures or damage that could have been discovered or avoided by proper inspection and testing prior to installation Conglom Kitchen amp Bath warrants this product to be free from defects in materials or workmanship for one 1 year from the date of purchase Proof of purchase original sales receipt from the original consumer purchaser must be made available to Conglom Kitchen amp Bath for all warranty claims This warranty is non transferable and shall be v
10. n warrantable items include but are not limited to Improper installation not in accordance with manufacturer s instructions Dents and or scratches incurred during shipping handling or installation Change in colour or finish due to chemical usage Damage caused by failure to follow care and cleaning guidelines including damage caused by the use of abrasive cleaners Alterations made to the unit by the purchaser or installer Damage caused by accidental impact fire flood freezing and normal wear Bends and warping caused by forced connections over tightened fittings and inadequate support during installation This warranty does not extend to commercial and institutional installation or use WARRANTY CLAIM PROCEDURE If a claimable defect occurs or replacement parts are needed please contact our customer service team at customer service conglomkb com or 1 877 333 0098 8 30 am 5 pm EST Monday Friday Before you make your call please ensure that you have Model number or description Proof of sale Details regarding the defect and or part number Name s and address es of the owner and installer CONGLOMKB COM Please contact 1 877 333 0098 for further assistance Pre Installation TOOLS MATERIALS REQUIRED NOT SUPPLIED Measuring tape Carpenter s square Nu Je Wrenches Phillips screwdriver Electric drill with 1 4 in 7 mm drill Pencil bit Safety gloves C AJ Safety
11. o the column body S and handheld shower head W with rubber washers N U Check valve X comes pre installed in handheld shower S NOTE Make sure that none of the hoses are bent or kinked after final installation Check water connections for proper flow make sure there are no leaks Do not forget to use the rubber washers to prevent leaks on the connections If you find that the water pressure or volume is low clean the mesh gasket C IF YOU HAVE A SHOWER STALL OR TILES WITH AN ENEVEN SURFACE Measure the length of the gap between the top of the shower panel and the stall see Fig 26 Cut both aluminum covers DD with scissors to desired length Remove the paper backing from the aluminum covers DD then stick them on the gap from the panel to the wall Stick the aluminum covers DD in place see Fig 27 Distance DD d Fig 26 Fig 27 10 Operation To use the shower panel open your shower valve as per normal use and flip the diverter valve on the shower valve or on the tub spout to redirect water from the toe tester or tub s spout to the shower Use the selector switch Fig 28 30 to choose between the three single use options 1 Shower head 2 Body jets 3 Handheld shower You can also choose three combined use options by placing the selector in between the icons Fig 31 33 4 The shower head and the handheld COMBINED 5
12. oided if the unitis removed from its initial installation or if itis not installed following the manufacturer s instructions It does not apply in the event of product damage due to the use of other than genuine Conglom Kitchen amp Bath replacement parts Replacement parts may be obtained by e mail at customer service conglomkb com or by calling 1 877 333 0098 between 8 30 am 5 00 pm EST installation error abuse misuse or improper care and maintenance whether performed by a plumber contractor service provider or member of the purchaser s household The warranty excludes damage due to aggressive air or water conditions harsh or abrasive cleaners and or materials Under no circumstance shall we be held liable for personal injury or property damage resulting from improper installation or use of this product We will not be held liable for inconvenience caused by loss of use of this product costs incurred for labour or materials removal and installation of replacement units or any other incidental or consequential damages Costs relating to obtaining access for repair or replacement are the responsibility of the user Our obligation shall be limited to the repair or replacement of a unit at our discretion that may prove by our sole examination to be defective under normal use and service during the warranty period Any failure of this product that is not traceable to a defect in material or workmanship is not covered by this warranty These no
Download Pdf Manuals
Related Search
Related Contents
Fujitsu ESPRIMO E9900 Welcome Guide VPAP™ ST with iVAPS Pelonis HB-215T User's Manual ノートン フラップディスク ノートン フラップディスク TXA-800, TXA-800CD, TXA-802CD DECAP`JELT - ITW Spraytec Manual de usuario GridLink Copyright © All rights reserved.
Failed to retrieve file