1. BK PAICGCIMAr  eee N VI    Model  1280B    Benchtop Computer Monitor Generator    USER MANUAL       Safety Summary    The following safety precautions apply to both operating and maintenance personnel and must be observed during  all phases of operation  service  and repair of this instrument  Before applying power  follow the installation  instructions and become familiar with the operating instructions for this instrument     Failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety  standards of design  manufacture  and intended use of the instrument  B amp K PRECISION assumes no liability for a  customer   s failure to comply with these requirements  This is a Safety Class I instrument     GROUND THE INSTRUMENT    To minimize shock hazard  the instrument chassis and cabinet must be connected to an electrical ground  This  instrument is grounded through the ground conductor of the supplied  three conductor ac power cable  The power  cable must be plugged into an approved three conductor electrical outlet  Do not alter the ground connection   Without the protective ground connection  all accessible conductive parts  including control knobs  can render an  electric shock  The power jack and mating plug of the power cable meet IEC safety standards     DO NOT OPERATE IN AN EXPLOSIVE ATMOSPHERE    Do not operate the instrument in the presence of flammable gases or fumes  Operation of any electrical instrument  in such an environ
2. RECISION  640x480 VGA SVGA 800x600    640x480 EGA 8514A 1024x768  640x480 CGA 1024x768 1152x870    512x384 MDA 1280x1024 1280x1024    X       COMPUTER  VIDEO QUTPUT MONITOR TESTER  DB15  DB9  See MDA  CGA  amp  EGA  System Type DB15 MAC  Switch    Power    Slide switch for power on or off    Power Indicator    LED to show when power is on    System Type Switch    Selects Mac or PC Columns   Monitor Type Selector     Selects Monitor type  Resolution   Video Pattern    Step through Colorbar  Crosshatch  Dot  and Raster Push button   MDA  CGA or EGA Connector   9 pin Female  D type   MAC Connector   15 pin Female  D type   VGA  SVGA   amp  1814A Connector   15 mini pin Female  D type     BACK PANEL  not shown      AC Power Input   AC Voltage Selector   Fuse Holder    Located directly under the AC Power Input   Four DB15 mini pin Female Jacks    Allows burn in or testing of multiple Monitors  RGB BNC    Red  Green and Blue video with sync on Green   H HV  amp  VBNC    Horizontal and Vertical Sync outputs    FEATURES    Tests MDA CGA  EGA  VGA  SVGA   amp  MAC Monitors  Resolution 720x350  640x480  800x600  1024x768   1280x1024  512x384  830x624   amp 1152x870   Interlaced  amp  Progressive   Provides Color bars  Cross hatch  Dots  Color   Raster  amp  Window   Connectors are 9pin D MDA  CGA  amp  EGA   15pin  D MAC   15minipin D  VGA  SVGA  and 8514A   Single push button selectable patterns   e Multiple monitor testing or burn in    BASIC OPERATION   1  Place the monitor type swi
3. VESA 1024x 768 48 5  1280 x 1024 64 0  MAC 512x384 24 4  640 x 480 35 0  640 x 480 35 0  640 x 480 35 0  830 x 624 49 7  1152x 870 68 7  1280 x 1024 80 0  Connector Pin Assignments   15 HD  Pin No Function  1 Red Video  2 Green Video  3 Blue Video  4 Not used  5 Ground  6 Ground  7 Ground  8 Ground  9 Not used  10 Ground  11 Not used  12 Not used  13 Hor  Sync  14 Ver  Sync  15 Not used  General     Polarity Vertical Polarity   Hz     50    60    60    60 2    56      87    2 60      60      60   Composite Sync    67   Composite Sync    67   Sync on Green    67   Separate Sync    75   Composite Sync    75   Composite Sync    75   Composite Sync  15 DB TTL 9 D  Function Function  Ground Ground  Red Video Intensity  Hor  Comp Sync Red Video  Not used Green Video  Green Sync Blue Video  Ground Intensity  Not used Intensity  Not used Hor  Sync  Blue Video Ver  Sync  Not used  Ground  Ver  Sync  Ground  Ground  Hor  Comp Sync    Power Source  AC 115Vac 230Vac  50 60Hz   10    Dimensions  HxWxD   3 9    x 10 25    x 10 8     99 x 260 3 x 274 3mm   Weight  3 1 Ibs   1 4 kgs      NOTE  Specifications and information are subject to change without notice  Please visit  www bkprecision com for the most current product information     Package Contents    The 1280B is shipped with   e 1280B Instrument  e Printed Instruction Manual  e Line Cord    Controk and Indicators    Power Switch    Power Indicator  Monitor Type Selector Auto Manual stepping  Pattern selector  Pushbutton    MAC PC  P
4. e product     WARNING  Do not alter the ground connection  Without the protective ground connection  all accessible  conductive parts  including control knobs  can render an electric shock  The power jack and mating  plug of the power cable meet IEC safety standards     WARNING  To avoid electrical shock hazard  disconnect power cord before removing covers  Refer servicing to  qualified personnel     CAUTION  Before connecting the line cord to the AC mains  check the rear panel AC line voltage indicator   Applying a line voltage other than the indicated voltage can destroy the AC line fuses  For continued  fire protection  replace fuses only with those of the specified voltage and current ratings     CAUTION  This product uses components which can be damaged by electro static discharge  ESD   To avoid  damage  be sure to follow proper procedures for handling  storing and transporting parts and  subassemblies which contain ESD sensitive components     Contents    Safety Summary nennen                              a  RSP UL LINING cn ee een  Package Contents ae era ons apts aed de eee  Controls and BID iri E ak  FEATURES au ns ie ea  BASIC OPERATION    una ee era  Use of Pattern Appliealanse   ana ee ee              SERVICE INFORNERTION  sense ee ee  LIMITED ONE YEAR WARRANTY un  elageeie    Specifications    Resolutions   Type Resolution Horizontal   KHz   MDA 720x350 18 4  CGA 640 x 200 15 8  EGA 640 x 350 21 8  VGA 640 x 480 31 5  SVGA 800 x 600 35 2  8514A 1024 x 384 35 5  
5. iginal packaging to the address below  Clearly state on the RMA the performance problem and return any leads  probes   connectors and accessories that you are using with the device  Customers not on an open account must include payment in the form of a  money order or credit card  For the most current repair charges please refer to the service and support section on our website        Return all merchandise to B amp K Precision Corp  with pre paid shipping  The flat rate repair charge for Non Warranty Service does not  include return shipping  Return shipping to locations in North America is included for Warranty Service  For overnight shipments and non   North American shipping fees please contact B amp K Precision Corp     B amp K Precision Corp   22820 Savi Ranch Parkway  Yorba Linda  CA 92887  www bkprecision com  714 921 9095    Include with the returned instrument your complete return shipping address  contact name  phone number and description of  problem     LIMITED ONE YEAR WARRANTY    B amp K Precision Corp  warrants to the original purchaser that its products and the component parts thereof  will be free from defects in  workmanship and materials for a period of one year from date of purchase     B amp K Precision Corp  will  without charge  repair or replace  at its option  defective product or component parts  Returned product must be  accompanied by proof of the purchase date in the form of a sales receipt     To obtain warranty coverage in the U S A   this prod
6. ment constitutes a definite safety hazard     KEEP AWAY FROM LIVE CIRCUITS    Instrument covers must not be removed by operating personnel  Component replacement and internal adjustments  must be made by qualified maintenance personnel  Disconnect the power cord before removing the instrument  covers and replacing components  Under certain conditions  even with the power cable removed  dangerous  voltages may exist  To avoid injuries  always disconnect power and discharge circuits before touching them     DO NOT SERVICE OR ADJUST ALONE    Do not attempt any internal service or adjustment unless another person  capable of rendering first aid and  resuscitation  is present     DO NOT SUBSTITUTE PARTS OR MODIFY THE INSTRUMENT    Do not install substitute parts or perform any unauthorized modifications to this instrument  Return the instrument  to B amp K Precision for service and repair to ensure that safety features are maintained     WARNINGS AND CAUTIONS    WARNING and CAUTION statements  such as the following examples  denote a hazard and appear throughout this  manual  Follow all instructions contained in these statements     A WARNING statement calls attention to an operating procedure  practice  or condition  which  if not followed  correctly  could result in injury or death to personnel     A CAUTION statement calls attention to an operating procedure  practice  or condition  which  if not followed  correctly  could result in damage to or destruction of part or all of th
7. tches to the proper position for the type of monitor to be tested   2  Connect the monitor to the proper video output connector    3  Turn on the power to both the monitor and the test unit    4  Press the video pattern push button to step to the desired pattern          Setting Auto Manual Switch to AUTO allows the output to scroll through the patterns automatically     Use of Pattern Applications    The primary use of this pattern generator is to provide a quick check of the operating condition of a  monitor and to allow for the adjustment of the external controls for the best performance     CROSSHATCH or DOT      These patterns are used to check static and dynamic convergence   linearity and pin cushion settings     COLOR BARS      The color bars are used to test the monitors ability to produce proper colors     RASTER      Typically used to check the purity of the primary colors  When these are properly  adjusted the white raster should appear pure white     SERVICE INFORMATION    Warranty Service  Please go the support and service section on our website www bkprecision com to obtain aRMA    Return the product  in the original packaging with proof of purchase to the address below  Clearly state on the RMA the performance problem and return any  leads  probes  connectors and accessories that you are using with the device        Non Warranty Service  Please go the support and service section on our website www bkprecision com to obtain aRMA    Return the  product in the or
8. uct must be registered by completing a warranty registration form on our website  www bkprecision com within fifteen  15  days of purchase        Exclusions  This warranty does not apply in the event of misuse or abuse of the product or as a result of unauthorized alterations  or repairs  The warranty is void if the serial number is altered  defaced or removed     B amp K Precision Corp  shall not be liable for any consequential damages  including without limitation damages resulting from loss of use   Some states do not allow limitations of incidental or consequential damages  So the above limitation or exclusion may not apply to you     This warranty gives you specific rights and you may have other rights  which vary from state to state     B amp K Precision Corp   22820 Savi Ranch Parkway  Yorba Linda  CA 92887  www bkprecision com  714 921 9095    BK CIGK RI a    22820 Savi Ranch Parkway  Yorba Linda  CA 92887    www bkprecision com       2009 B amp K Precision Corp     Printed in China v121608    
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
User's Guide: - QNX Software Systems  Fujitsu 9368987046 User's Manual  télécharger le fichier PDF ici - MRC  MANUAL DO UTILIZADOR  ASUS G750JM User's Manual  取扱説明書  Mode d'emploi  Rapoo A3160  Chamberlain 2255-2 Garage Door Opener User Manual  Bedienungsanleitung    Copyright © All rights reserved. 