Home
Auto-leveling Rotating Laser (RL430S)
Contents
1. 3 Rotate the instrument by 90 degree in turn after the instrument is auto leveled mark the intersection point between the laser line and the vertical line as sign B C and D 4 Measure the maximal distance between two points which amount point A B C D If h 3mm the accuracy is OK If 3mm lt h 20mm the accuracy is beyond tolerane it need to be calibrated If h gt 20mm the accuracy is beyond tolerance user must contact with seller for service Wall es Er ca Vertical line P atform WM 5 2 Accuracy calibration According to the test result of instrument accuracy check mark a sign O at the place h 2 in the middle of the highest point and the lowest point among A B C D 1 Enter the calibration mode a Turn off the instrument take the X axis of the instrument to face the wall b Press the Man Slope mode key together with power on key then release the power on key and hold on pressing the Man Slope mode key until the X Y Z three LED flashing three times Then release the Man Slope mode key and the instrument enters the calibration mode keep rotating 2 X axis calibration a press the self calibration axis selecting key on the remote control the X direction calibration LED flash instrument enter the X direction calibration mode b Press the self calibration adjustment key on the remote control make the laser line move up and down until coincident with the point O 3 Y axis calibration a In ca
2. Light Single axis slope mode is on Extinguish Single axis slope mode is off Man mode LED Light Dual axis slope mode is on Extinguish Dual axis slope mode is off Slope axis direction LED For X Y Z LED when one axis is in slope setting status its corresponding LED will light Wind save mode LED Flash Wind save mode is on Extinguish Wind save mode is off Mobile 022 070 6986 Email dave davebell co nz www davebell co nz ELECTRONIC EQUIPMENT LIMITED DaveBel 4 5 Power on off key oO a Press power on off key the instrument start on power LED light b Instrument is in auto leveling status when power on the rotating speed is 800rpm after auto leveled 4 6 Speed key The instrument is in rotating status after power on and auto leveling The rotating speed is 800rpm Press speed key to switch rotating speed as follows l The first press The second press Q Rotating speed 800 rpm 8 00 rpm rpm The third press 4 7 Area scan mode key S a Press the area scan key when the instrument is rotating area scan mode is on the scan angle is 180 continuously press this key the scan angle will change as below picture shows The first press The second press The third press The fourth press eee Areascan 130 meje 0 o_o 45 oo 0 _ 0 gee 45 The seventh press The sixth press The fifth press b Press area scan key when the instrument rotating speed is 0 the area scan mod
3. instrument on a leveled plane horizontally b Install the instrument on the tripod by the 5 8 screw thread on the side of instrument Place the instrument a leveled plane horizontally Mobile 022 070 6986 Email dave davebell co nz www davebell co nz DaveBel ELECTRONIC EQUIPMENT LIMITED Install the instrument on the tripod by the 5 8 screw thread on the side of instrument When place the instrument horizontally in order to make the vertical reference plane over the fulcrum please adjust the level hand wheel to make the bubble vial centered Adjust the hand wheel to make the bubble vial centered Mobile 022 070 6986 Email dave davebell co nz www davebell co nz DaveBel ELECTRONIC EQUIPMENT LIMITED 4 4 Keypad Area scan spot clockwise shift key Wind save mode key Wind save mode LED Area scan mode key Remote shield LED TILT mode Key Area scan spot anticlockwise shift key CON DOO FP ON Slope axis direction LED 9 TILT mode LED 10 Remote shield key 11 Auto leveling key 12 Power LED 13 Power on off 14 Speed key 15 Slope mode LED 16 Man slope key 17 Man mode LED Power LED Light Power is on Extinguish Power is off Flash Low power TILT mode LED Flash slowly 1 time second TILT ready mode is on Light TILT mode is on Flash quickly 2 times second TILT alarm mode is on Extinguish TILT mode is off Slope mode LED
4. press TILT key will have no response Mobile 022 070 6986 Email dave davebell co nz www davebell co nz DaveBel ELECTRONIC EQUIPMENT LIMITED Three leveling modes Stop rotating to auto leveling after autoleveled the instrument Normal mode continue to rotate the alarm will not work if the instrument is in the auto leveling range B Stop rotating and not auto leveling alarm sound 2 LED flashing quickly TILT mode LED light Keep rotating and Stop rotating and not 8 auto leveling no alarm auto leveling alarm sound LED light Wind save mode 3 amp LED flashing quickly LED light after auto level for 30 seconds 4 11 Man Slope key a In horizontal wotniuiy status X LED light X axis in slope Press the key 5 mode Y axis is auto leveling Single axis the first time l Slope LED on remote control to ope in press j light choose the slope direction Y LED light Y axis in slope slope mode N noge i on XY direction Then mode X axis is auto leveling press E to adjust the slope value X LED light X axis in slope l mode Y axis is quiescent Double axis the second l Man LED l slope in Man time press g light Y LED is light Y axis in slope mode mode X axis is quiescent the third time Slope mode is off enter normal mode press Mobile 022 070 6986 Email dave davebell co nz www davebell co nz ELECTRONIC EQUIPMENT LIMITED DaveBel b In vertica
5. ELECTRONIC EQUIPMENT LIMITED DaveBel Auto leveling Rotating Laser rusos ELECTRONIC EQUIPMENT LIMITED of long term use of this instrument we suggest you to read this instruction manual carefully before using it Contents 1 Features and Functions 2 User Safety 3 Nomenclature 4 Operation Instruction 5 Self check and Calibration 6 Instrument Application 7 Technical Specifications 8 Maintenance Mobile 022 070 6986 Email dave davebell co nz www davebell co nz ELECTRONIC EQUIPMENT LIMITED DaveBel 1 Features RL430S auto leveling rotating laser could project visible horizontal laser plan and plumb up laser beam amp vertical laser plan and horizontal laser line Its extensive functions bring great convenience to set accurate horizontal vertical and plumb references for indoor and outdoor lay out and calibrations This kind of product is featured by easy manipulation and wide applications e Electronic leveling laser stop rotating and sound indication when beyond range e 360 rotating could work vertically and horizontally e Adjustable rotating speed and scan angle e TILT mode has the unleveled alarm function the laser head stop rotating to insure the construction accuracy when the instrument is hit e Wind save function could set the instrument to be low sensitive to insure the reliable wild working performance e SLOPE mode function could set the single slope plane that means when
6. S 400m High 800 100 rpm Rotary speed Low 300 100 rpm Speed is 0 Accuracy 0 075mm m Scan angle 10 45 90 180 Temperature 10 C 45C 3 IP class Power C batteries or rechargeable Li battery pack Size 219mmx 160 mmx 202 mm Weight 2 4 Kg 8 Maintenance e The instrument should be carefully operated and properly preserved and any violent shock or falling will possibly result in the damage of instrument e Do not attempt to disassemble the instrument and the unprofessional disassembly will result in the damage of instrument e Keep the cleanness of instrument especially the laser output window and remove dust by the gentle operation of soft clean cloth e Take the batteries out when the instrument is not in use for a long time and keep the instrument in the carrying case when it is unused e Avoid being wet with water and rain Mobile 022 070 6986 Email dave davebell co nz www davebell co nz
7. e is on scan angle is 10 Continuously press this key the scan angle will change as below picture shows The first press The second press The third press The fourth press je Area scan 0 m Ag os 30 Lag t 45 te a0 a The seventh press The sixth press The fifth press 4 8 Area scan spot clockwise anti clockwise shift key 8 a Press area scan spot clockwise anti clockwise shift key in the area scan mode the scan area will move as the arrowhead shows press the key to mowe slowly hold on pressing this key to move quickly b Press area scan spot clockwise anti clockwise shift key in the laser spot mode the laser spot will move as the arrowhead shows press the key to move slowly hold on pressing this key to move quickly Mobile 022 070 6986 Email dave davebell co nz www davebell co nz ELECTRONIC EQUIPMENT LIMITED DaveBel 4 9 TILT mode key amp TILT mode operating steps Normal mode is on Press amp Press oO Power on Tilt mode is on After auto leveling for 30 seconds Instrument shaking Stop rotating not leveling Press Re leveling enter TILT mode a Ifthe Man mode is on press TILT key the instrument will exit the Man mode 4 10 Wind save mode key Q Wind save mode operating steps Poweron press CJ Wind save mode is on gt a Ifthe instrument is in the Man mode press the wind save mode key the instrument will exit the Man mode b In the wind save mode
8. l working status LED light X axis in slope mode Z axis is Slope LED light jauto leveling The first time Single axis Slope press in slope mode Press the key tj X LED light On the remote control X axis is in slope mode Z Double axis slope to choose the slope axis is quiescent in Man mode Man LED light direction on X Z Z LED light mode then press Z axis is in slope mode X to adjust the slop axis is quiescent value the second time press the third time press Slope mode is off enter normal mode c When the instrument enters the slope mode it will keep wind save mode and TILT mode d When the instrument enters the Man mode it will exit the wind save mode and TILT mode Press the TLIT mode ke or wind save mode key the instrument will exit the Man mode and enter the auto leveling mode 4 12 Auto leveling key Press this key the instrument enter the auto leveling mode When the instrument is in TILT alarm status press this ke instrument will exit the alarm mode and begin to auto level And it will keep the TILT mode after auto leveling when instrument is in Man Slope situation press this key to exit slope mode and enter the auto leveling mode 4 13 Remote shield key T Press this key remote shield LED light the instrument could not receive the remote signal Press this key again LED extinguished and instrument could receive the remote signal again Mobile 022 070 6986 Email dave davebell co nz www da
9. libration mode rotate the instrument 90 degree to make Y axis face to the wall b Press the self calibration axis selecting key on the remote control the Y direction calibration LED flash instrument enter the Y direction calibration mode c Press the self calibration adjustment key on the remote control make the laser line move up and down until coincident with the point O Mobile 022 070 6986 Email dave davebell co nz www davebell co nz ELECTRONIC EQUIPMENT LIMITED DaveBel 4 Calibration confirmation When the calibration of X direction and Y direction are all finished please press self calibration confirmation key the calibration LED closed calibration value is saved and instrument exit the calibration mode Note In order to make the said calibration effective you must power off the instrument after the said calibration and then power on it again Y axis accuracy check is a necessity after Xaxis calibration and X axis accuracy check is also a necessity after Y axis calibration Instrument self calibration will not be fulfilled until both Xaxis and Y axis accuracy meet the requirement 6 Instrument Applications M y 4 a Vera r Sa a ayn ra Mobile 022 070 6986 Email dave davebell co nz www davebell co nz ELECTRONIC EQUIPMENT LIMITED DaveBel 7 Technical Specifications Laser wave RL430S 635nm RL430S 532nm Laser class Class II II Output range RL430S 600m RL430
10. setting one single axis the other axis will be self leveled e MAN mode function could set the double axis slope and forcing rotating status That means operators could set the slopes declining in both axis if necessary or make the instrument into rotating status directly e Accuracy self calibration function e Timing auto off function e Remote control operation function e Connecting with the tripod through the 5 8 screw thread e Various accessories of elaborate design can bring usage expansion e Rainproof and dustproof 2 Usage safety e Laser output sign lies near the output aperture e Do not stare into laser beam directly e Do not disassemble the instrument or attempt to perform any internal servicing Repairs and servicing could be performed only by authorized service centers e The instrument complies with the safety classification standards of laser radiation Mobile 022 070 6986 Email dave davebell co nz www davebell co nz DaveBel ELECTRONIC EQUIPMENT LIMITED 3 Nomenclature Laser output window Rotating head Ei Remote receiving tube g D 0 Handle Keypad Leveling hand wheel for vertical working status Bubble vial Fulcrum Side 5 8 screw thread Battery cover screw Battery cover Center 5 8 screw thread hole Mobile 022 070 6986 Email dave davebell co nz www davebell co nz DaveBel ELECTRONIC EQUIPMENT LIMITED 4 Operation Instruction 4 1 Bat
11. tery installation a Put 3 C alkaline batteries into the battery box follow the marked polarity direction and install the battery box to the instrument Install alkaline battery b Install the rechargeable battery into the instrument Install the rechargeable battery box 4 2 Charge the rechargeable battery Charge the rechargeable battery directly by the adapter The LED is red during the charging process the LED will turn green when the battery is full Charging LED Adapter Charge the rechargeable battery box directly Mobile 022 070 6986 Email dave davebell co nz www davebell co nz DaveBell ELECTRONIC EQUIPMENT LIMITED Charge the rechargeable battery box on the instrument Note please charge the rechargeable battery when the battery is empty the power supply LED flash mean the battery is already empty That could extend the battery service life 4 3 Instrument placement In horizontal working status a Place the instrument on a leveled plane directly b Install the instrument on the tripod by the 5 8 screw thread on the instrument base 2 DaveBell ELECTRONIC EQUIPMENT LIMITED Place the instrument on a leveled plane Mobile 022 070 6986 Email dave davebell co nz www davebell co nz DaveBel ELECTRONIC EQUIPMENT LIMITED Q Q Install the instrument on the tripod by the 5 8 screw thread on the instrument base In vertical working status a Place the
12. vebell co nz ELECTRONIC EQUIPMENT LIMITED DaveBel 4 14 Remote Keypad Scan function mode key Slope axis direction selection key Rotating speed key Auto leveling key 1 2 3 4 5 Selfcalibration axis selection key 6 Self calibration adjustment key 7 Self calibration confirmation key 8 Remote shield key 9 Slope adjustment key 1 0 Area scan sopt clockwise anti clockwise shift key a The rotating speed key area scan key area scan spot clockwise shift key area scan spot anti clockwise shift key on the remote control are same as the keys on the main instrument b When the instrument is in the Man Slope mode press the slope adjustment key on the remote control to adjust the inclined angle of laser plane or laser line 5 Self check and Calibration Users should make a self amp Check and calibration after using the instrument for a period or before implementing a big project If the accuracy is beyond range the users can do the check and calibration according to the method below Mobile 022 070 6986 Email dave davebell co nz www davebell co nz ELECTRONIC EQUIPMENT LIMITED DaveBel 5 1 Accuracy check 1 Set a platform in a room which is 20m far way from the wall put the instrument on the platform and take the X axis face to the wall 2 Power on and after the instrument is auto leveled mark the laser line which is on the wall as sign A and make a vertical line from sign A
Download Pdf Manuals
Related Search
Related Contents
Designer User Manual - Phoenix Learning Systems do manual Samsung CE107V Manuel de l'utilisateur RS-KeyboardAR 取扱説明書 2. - AVerMedia AVerTV Global I-110 XL/XL2 - Ashland Industries, Inc. Descargar Copyright © All rights reserved.
Failed to retrieve file