Contents

1. eg CER rego o O de 6 S2 Application IOC arseen le east are rs ian eu KE GN eaten eae ce ante ag 6 So SV SCCM NOC Gs oe 03 oh Macatee diet ag GA et ak alte Na adhe tela esate ei ada nak an ats 6 5 4 Kernel mode G2 TTOUDIESHOG HIS ves Heart A 9 1 Introduction The 8100 series are compact light weighted high performance RF data terminals designed for all day everyday use It can be powered by either two AAA size batteries or just a rechargeable Ni MH battery pack It is supported by a rich set of development tools including a Windows based application generator C and Basic compilers With its integrated Laser CCD barcode scanning unit and built in RF module the 8100 series is ideal for real time applications such as shop floor management warehousing and distribution operations 2 General Features and Characteristics Basic characteristics of the 8 00 RF Terminal are listed below 2 1 Electrical Operation battery two AAA size disposable or rechargeable batteries Backup battery 3 0V 7 0mAh rechargeable Lithium battery for SRAM amp calendar ti Working time over 20 hours for 8110 433Mhz RF model and 8 hours for 8150 2 4GHz RF model 2 2 Environmental ti Humidity operating non condensed 10 to 90 Humidity storage non condensed 5 to 95 Temperature operating 20 to 60 C Temperature storage 30 to 70 C EMC regulation FCC class A CE 0560 Shock resistance 1 2m drop on
2. needs about 1 5 sec continuous pressing to turn On Off the power 5 2 Application mode This is the default operation mode when turning on the power The operation depends on the application module Please refer to section 4 4 5 3 System mode When pressing the 7 9 and POWER keys simultaneously the system will enter the System Mode with which provides the following services 1 Memory Size Information Includes the SRAM Data memory size and FLASH Program memory size in kilobytes Initialize Test 2 Setting Clock Backlit Speed Auto Off Power On Key Click Password 433M 2 4G RF 3 Reader To initialize the data memory RAM Note that the contents of the data space will be wiped out after memory initialization To test the data memory For 256 KB SRAM it takes about 15 seconds to finish the test Note that the contents of the data space will be wiped out too after memory test To set new date and time To set the intensity of LCD back light and the duration for staying on Default High intensity the lights go off after 20 seconds To set CPU running speed There are five speeds available Full speed 1 2 speed 1 4 speed 1 8 speed and 1 16 speed Default Full speed Set time threshold for auto power off when no operation is taking place during that specified period If this value is set to zero this function will be disabled Default 10 minutes There are two possible selections Program R
3. persists call for service Battery low indicator is on y Change the batteries Cannot download application program from the host to the 8 00 RF Terminal or vice versa via RS 232 port y Check if the RS 232 cable is plugged tightly then y Check if host communication parameters COM port baud rate data bits parity stop bit match the 8 00 RF Terminal s Keypad does not work properly y Turn off the power then press the 7 9 and POWER keys simultaneously to enter the kernel mode operation y From the system menu select the Test and then its sub item KBD y Perform the key in test y If problem persists call for service Scanner does not scan y Check if symbologies used are enabled or y Check if battery low indicator is shown on the LCD display If yes change the batteries y If problem persists call for service Abnormal responses y Open the battery cap and re load the batteries y Enter system menu by pressing 7 9 and POWER keys simultaneously y Check if the 8 00 RF Terminal can have a correct response by performing entering data y If problem persists call for service
4. 1 Keypad operations The keypad of 8 00 RF terminal consists of 20 rubber keys and one trigger key The functions of some special keys are as follows ENTER Enter This key is for command execution or input confirmation BS Back Space If pressed down longer than one second a clear code will be sent SP Space UP Cursor up DOWN Cursor down Alpha The toggle key for Alphabet Numeral input When the system is in alpha mode a small icon will be shown on the display and each numeral key can be used to generate one of the three capital letters For example numeral 7 can be used to produce A B or C Pressing the same key twice within one second will call the letter B Pressing the same key without halting longer than one second will cause the three letters to be shown in a circulating way Only when stop pressing the key for longer than one second or pressing another key will the system send the real key code to the application program FN The function key This key can not be activated alone it must be pressed with one numeral key at the same time For example FN 1 generates function 1 FN 2 generates function 2 etc up to 9 functions Also this key can be combined with the UP DOWN arrow keys to adjust the contrast of the LCD And when this key is combined with the ENTER key it will turn ON OFF the LCD backlit ESC Escape Usually this key is used to exit current operation POWER Power On Off To prevent a faulty push it
5. CipherLab 8100 Series Users Guide Version 1 00 Copyright 2002 Syntech Information Co Ltd CIPHER SYNTECH INFORMATION CO LTD Head Office 8F No 210 Ta Tung Rd Sec 3 Hsi Chih Taipei Hsien Taiwan Tel 886 2 8647 1166 Fax 886 2 8647 1100 e mail support cipherlab com tw http www cipherlab com tw Table of Content TAS ECM GN o NG NAN GN o ERD i l Introductions aisian ot tts NE a EA ha Rete E S NT 2 General Features and Characteristics 0 0 ccccccccccssesseeseessessessestestestesteseseseeseeses o tA aback E E A 2 2 NOY OMICS IA iiiaio i e E A NGNE AG KAGAN A GN AG GN R an 2 3 PHySi cal aana gan a ecto AN AE a es PR aaa a ge AN I a tL RET a a ge a a 2A CPU sasa a a AP A a D DG a ka a e a D nag aka DSU MO A LO CANNING a a A PG E IANT O A OEE AY aaa 2 8 Keypad saka id 2 0 MINAS A A 2 TO COMMUNICA ON nia 2 11 Programming Language sesa aeses ead conta anae anana anan anan anana awanan anana Dek 2 AAC O ds a dd el at lia ada naa e A 3 RF Configuration Software AO dde 5 A aaa ehh cad aka a GAN naa naa ND adalat alsa aa ang le aii 5 4 2 System module the operating system aasenenaeee anana n aana n anan anana awanan n awanan 5 4 3 Application MOdUless e541 e o e do o o o ea ens 5 4 4 Build your own application module 2 0 0 cece ceececeseeeeeeeceseeeeeseseeeeeseseteeseseseeeeees 5 A erie Meter Nite en a EN Tene Ue ote Nee ee eR eer 6 5 l Keypad peration ne a pe
6. esume which starts from the program being used during the last session before the last power off and Program Restart which starts with a new program Default Program Resume To enable or disable the key click when users press the key buttons Default Enable To set password protection for entering the system menu Default no password is set To set the RF properties for the terminal including ID channel output power level time for auto search channel and time out for sending Note that these settings can be overwritten by user s application program Default Terminal ID 01 Terminal Channels 01 Terminal Powers 01 Auto Search Time 10 Send Timeout 02 To test the reading performance of the scanner Following are the default enabled symbologies Code 39 Industrial 25 Interleave 25 Codabar Code 93 Code 128 UPCE UPCE with ADDON 2 UPCE with ADDON 5 TANG ETANG with ADDON 2 ETANG with ADDON 5 EANI3 EANI3 with ADDON 2 EANI3 with ADDON 5 Other symbologies must be enabled through programming 4 Battery Show voltage of the main battery and backup battery 5 Test Buzzer To test the buzzer with different Frequency Duration Press ENTER key to start stop the test LCD LED To test LCD display and LED indicator Press ENTER key to start stop the test KBD To test the rubber keys Press a key and the result will be shown on the LCD display Note that the FN key should be used in conjunction with nume
7. ion are provided standard RS 232 and RE RS 232 Transmission speed up to 115200bps 433MHz RF 9600bps data rate Coverage up to 200m line of sight 2 4GHz RF 19200bps data rate Coverage over 1000m line of sight 2 11 Programming Language C BASIC and a Windows based Application Generator 2 12 Accessories RS 232 cable Cradle Battery charger RF base station SS 3 RF Configuration 433 MHz RF terminal e Channel 1 4 e ID 01 45 Time out 1 99 seconds duration of retries for sending data e Output power 1 5 levels 10 5 4 0 5dBm e Auto search 0 99 sec automatically search for available channel when connection to current channel is lost 2 4 GHz RF terminal e Channel 1 6 e ID 01 99 Time out 1 99 seconds duration of retries for sending data e Output power 1 levels 100mWw e Auto search 0 99 sec automatically search for available channel when connection to current channel is lost 4 Software Organization The 8 00 RF Terminal system software consists of three modules the kernel module the system module and the application module 4 1 Kernel module Kernel module is the innermost core of the system It has the highest security and is always protected by the system Only the failure of flash memory or improperly power off during system restart after updating kernel will the kernel be destroyed The kernel module ensures that users can always download their
8. own program even the operating system was crashed by user s program The kernel provides the following services Program download Update kernel Test amp Calibrate Version Sere eS For detailed operations please refer to section 5 4 4 2 System module the operating system The system module provides the following system services Memory Setting Reader Battery Test Download Version cc c caca ca For detail operations please refer to section 5 3 4 3 Application module The Application module runs on top of the System module The 8 00 RF Terminal is preloaded with the Application Generator s run time program and the following menu will be shown upon powering the unit up Take data Utilities The arrow keys can be used to select the menu item and execute 1t by pressing the ENTER key Note if you use the Application Generator to create your application program you need to download it to the terminal and work with the RF Database Manager For detailed information please refer to RF Application Generators Users Guide 4 4 Build your own application module There are three software tools available for developing application programs 1 The Application Generator 2 The BASIC Compiler 3 The C Compiler For more information please contact CipherLab USA or Syntech Information Co Ltd 5 5 Operations Batteries must be fresh and properly loaded before start operation 5
9. ral keys 6 Download To download the user program via RS 232 port The transmission speed can be up to 115200 bps 7 Version To show version information including Hardware Version Serial Number Manufacturing Date Kernel Version Library Version and User Program Version 5 4 Kernel mode Press the 7 9 and POWER keys simultaneously to enter the System mode then power off and press 1 7 and POWER key simultaneously to enter the kernel mode which provides the following services Program download To download user program The download procedure is same as download Update kernel Test amp Calibrate Version program in system mode Please refer to the above section To update system kernel Sometimes the kernel might be changed for improving performance or other reasons This function allows you to keep the kernel updated The update procedure is same as download user program but note that after updating the kernel please do not power off until the system restart itself To perform a burn in test and fine tuning the system clock This function is for manufacture purpose only Information includes hardware version serial number manufacturing date and kernel version 6 Troubleshooting a b d e g Does not power up after pressing POWER key y Change the batteries Does not power up after changing batteries y Check if the batteries are properly installed with battery cap firmly closed y If problem
10. to concrete ca Ss css 2 3 Physical Dimensions 145mm L x 63mm W x 33 5mm H Weight 200g including batteries Color Dark gray Material ABS 2 4 CPU Toshiba 16 bit CMOS type CPU Tunable clock up to 22MHz ccc c Oe 2 5 Memory Program memory 1M Bytes flash memory is used to store the program code font constant data and so on Data memory 256 K Bytes SRAM 2 6 Scanner The 8 00 RF Terminal can be equipped with Laser or Long Range CCD scanners Detail specifications are as following SIIOL 8150L Laser Light source visible Laser diode operating at 670 15nm Scan rate 36 3 scans per second Scan angle 42_nominal Minimum print contrast 20 absolute dark light reflectance at 670nm Depth of field 5 95 cm depends on barcode resolution SS SiS 8110C 8150C CCD Resolution 0 15mm 1 00mm Depth of field 15cm Width of field 45mm 124mm Scan rate 30 scans sec Ambient Light Rejection 1200 lux Direct Sun light 2500 lux Fluorescent Light 2 7 Display 128x64 graphic dots FSTN LCD display with LED back light 2 8 Keypad 21 rubber keys including alphanumeric keys arrow keys function keys and scan trigger key 2 9 Indicator Buzzer Software programmable audio indicator 1KHz to 4KHz low power transducer type LED Programmable dual color green and red LED for status indication 2 10 Communication Two kinds of communicat

Download Pdf Manuals

image

Related Search

Related Contents

Konfigurations-Tool - Bosch Security Systems  Allied Vision Technologies AVT GigEGoldeye Specifications  Tecumseh AJA7490ZXD Drawing Data  JVC TH-M508 User's Manual  Portable Ventilation System  Quasar SP3234, SP3234U CRT Television User Manual  Mobotix MX-OPT-BOX-1-EXT-ON-BL    Manual Supervise 5.0  Das Spiel - DIR  