Home

13413 manual FlexTemp II.qxd

image

Contents

1. Ij dw xojd mg Digitales Fieberthermometer Deutsch Digital thermometer English Thermom tre digital Francais Termometro digitale Italiano Term metro digital Espagnol Term metro digital Portugu s Digitalt termometer Dansk Digitaalinen kuumemittari Suomi Digitalt feberthermometer Norsk Digitalt feberthermometeret Svenska Digitale koortsthermometer Nederlands Unotako Osppoperpo nvperov EAAnviKa Dijital klinik termometresi T rkce A Good Sense ot Health IM MC 206 E 05 12 08 FlexTemp I English 1 IMPORTANT SAFETY INSTRUCTIONS The thermometer is suitable exclusively for measurement of the body temperature The minimum measurement time until the signaling tone beep must be maintained without exception The thermometer contains small parts battery etc that can be swallowed by children Keep the thermometer out of the reach of children Damage may occur if the thermometer is dropped or struck against a hard surface Avoid ambient temperatures above 60 C NEVER boil the thermometer Use only the commercial disinfectants listed in the section cleaning and disinfecting to clean the thermometer The thermometer must be intact when immersed in liquid disinfectant Warning The thermometer contains a long life battery The lM symbol in the right bottom corner of the display indicates the battery needs to be changed Open the battery compartment by pulling the colored top
2. al use Name Dilution in water Immerse Isopropyl alcohol 70 95 0 30 min Sekusept plus Henkel 3 30min Sekusept Extra N Henkel 3 30 min Incides desinfection cloth Henkel Wiping according instructions Ethyl alcohol 95 30 min Do not use Chlorhexidine for disinfecting the thermometer Do not submerge this thermometer deeper than 15 cm and longer than 30 minutes Caution The tip of the thermometer contains Nickel 5 TECHNICAL SPECIFICATIONS Type Maximum thermometer FlexTemp Il MC 206 E Measurement range 32 C to 43 C 89 6 F 109 4 F Temp lt 32 0 C 89 6 F display Lo for low Temp 43 0 C 109 4 F display Hi for high Measurement accuracy 30 1 C between 32 0 C to 42 0 C 0 2 F between 89 6 F to 109 4 F at ambient temperature of 10 C to 35 C 50 0 F to 95 0 F Display Liquid Crystal Display LCD with 3 digits Smallest unit of display 0 1 C or 0 1 F For signaling that the thermometer is ready to use and that the temperature increase is less than 0 1 C 16 seconds Signaling tone Memory For storing the last measured value Storage temperature 25 C to 55 C 13 0 F to 131 0 F Battery LR41 AG3 or equivalent 1 5V Battery life Approx 200 hours 1000 Measurements This thermometer is designed according to the European Standard EN12470 2000 Clinical thermometers Part 3 Performance of compact electrical thermometers non predictive and predictive with maximum d
3. evice WARRANTY This product is guaranteed by Omron for 3 years after date of purchase Any damage caused by improper handling shall not be covered by warranty Batteries and packaging are also excluded from the warranty All other damage claims excluded A warranty claim must be submitted with the purchase receipt C 0197 A we Lf Read the instructions in this manual carefully Disposal of this product and used batteries should be carried out in accordance with the national regulations for the disposal of meme electronic products This device fulfills the provisions of the EC directive 93 42 EEC Kruisweg 577 2132 NA Hoofddorp The Netherlands www omron healthcare com Opal Drive Fox Milne Milton Keynes MK15 0DG United Kingdom Medical Device Directive Made in China Manufacturer Subsidiary OMRON HEALTHCARE OMRON HEALTHCARE UK LTD OMRON Medizintechnik OMRON SANT FRANCE SAS EUROPE B V ud Handelsgesellschaft mbH John Deere Str 81a 68163 Mannheim Germany www omron medizintechnik de 14 rue de Lisbonne 93561 Rosny sous Bois Cedex France
4. firmly Gently pull out the circuit board with battery compartment approximately 1 cm Remove the battery by pushing a thin plastic or wooden tip such as toothpick through the small gap at the side of the battery holder Push further to remove the battery from the holder Replace the used battery with a new one paying attention to the symbol on the battery which must be positioned upwards For disposal please comply with local regulations for special waste The manufacturer recommends that the accuracy is verified by an authorized laboratory every 2 years Please contact our Customer Services 0870 750 2771 0845 for advice for UK only 2 SWITCHING ON Press the on off button A short beep signal sounds the device is on All symbols show on the LCD display for a few seconds as a means of checking that the thermometer is functioning correctly If available the last correctly measured temperature is displayed indicated by the M symbol After this the device is ready for measurement indicated by a flashing C symbol and a Lo indication at an ambient temperature of less than 32 C 2a For changing between Fahrenheit and Celsius indication Keep the on off button pressed for approximately 4 seconds after switching on the unit 3 HOW TO USE THE THERMOMETER Position the sensor tip in the preferred place of measurement mouth rectum or armpit If the signaling tone beep beep beep beep sounds 4 times and the C is n
5. o longer flashing this means that the measurement is finished and that the thermometer is ready for reading In the mouth oral Position the thermometer under the tongue The measuring sensor must be in good contact with the tissue Close your mouth and breathe evenly through the nose to prevent the measurement from being influenced by inhaled exhaled air Approx measuring time 1 minute Normal temperature between 35 7 C and 37 3 C In the anus rectal This is the most reliable measuring method and is especially appropriate for infants and small children Carefully insert the tip of the thermometer 2 to 3 cm into the anal aperture Approx measuring time 1 minute Normal temperature between 36 2 C and 37 7 C In the armpit axillary From a medical viewpoint this method will always provide inaccurate readings and should not be used if precise measurements are required Approx measuring time 1 5 minutes Normal temperature between 35 2 C and 36 7 C Warning To prolong the life of the battery turn it off after use by pressing the operating button briefly Otherwise the thermometer will automatically turn off after about 10 minutes 4 CLEANING AND DISINFECTING OMRON recommends to wipe the device with damp cloth For disinfection 70 Ethanol or Isopropyl alcohol can be used Do not attempt to disinfect the sensing section of the thermometer by immersing in alcohol or in hot water water over 50 C For profession

Download Pdf Manuals

image

Related Search

Related Contents

CA series Digital Counter user manual  HP t5730 Quick Reference Guide  Operation, Installation and Service Manual  BellSouth 17 User's Manual  Mode d`emploi  Kenmore 1.4 cu. ft. Trash Compactor - Black Owner's Manual  Sony VAIO LM2E + Microsoft Office Small Business 2007    GW User Manual  PowerFlex 700 AC Drives  