Home
Open Voice Intercom System
Contents
1. button set ID number button For setting only melody pressing about 2 seconds Number of setting melody button After entering into setting mode if you do not press any button for 10 seconds it will automatically go to initial state 5 2 Master Station CM 810M How to use guidelines for CM 810M When you want to call and begin to talk 1 Press ID number of device to be called and then press button 2 If bell lasts over 1 5 seconds conversation mode automatically opens Example Calling to ID number 1 press 1 Bell sound will occur When you press wrong number error beep sound will occur It is possible to call from 1 to 10 and impossible to call into its ID number When you enter wrong number press and it will be annulated 3 When calling press Talk button and speak release Talk Button when listening When talking is over press again button and finish conversation Gh 3 When you are called from other unit and want to speak 1 If there is a call coming from another unit you will see in display window A call words appear after 1 5 seconds it get automatically in to speaking mode with appearing of N in display 2 During of transmission it is possible to talk without handling any button 3 If you press privacy button it will be impossible to make eavesdropping over master unit 5 COMMAx 5 Wiring 6 2 When we
2. Cleaning amp Use Power amp Installation Cleaning amp Use Please don t disassemble repair or rebuild this product arbitrarily please contact the service center if a repair is needed It may cause an electric shock or fire No disassembly Electric shock Fire Unplug Please plug the power cable firmly into the inner end It may cause a fire Raquest Fire Please be careful when using an AC circuit breaker since there is a possibility of an electric shock Request Electric shock When cleaning the product please rub it with a soft and dry cloth after plugging out the power cable Please don t use any chemical products such as wax benzene alcohol or cleanser Prohibition If an abnormal sound burning smeli or smoke is coming out of the product please plug out the power cable and contact a service center It may cause an electric shock or fire Efectric shock Fire Please hoid the plug tightly when unplugging the power cable a part of the copper wire may be disconnected if the grabbing is only made on the cord when pulling out the cable It may cause an electric shock or fire Request Electric shock Fire Please check the use voltage and current for the DC only products and use the appropriate rectifier t may cause a fire Request Fire Please don t drop the product on the ground and don t apply a shock It may cause a failure Pronibition
3. Blooming Life Open Voice Intercom System COMMAX Blooming Life HomeNetwork COMMAX Co Ltd COMMAX Co Ltd 513 11 Sangdaewon dong Jungwon gu Seongnam si Gyeonggi do Korea Int l Business Dept Tel 82 31 7393 540 550 Fax 82 31 745 2133 Web site www commax com ar precautions for safety e a product exactly Jents caused by abnormal Printed In Korea 2008 12 Contents Ne ee E A EE PE E reece ane eaepeanraaepenns 7 eS and O A Gar e eanceeesa 4 4 Or S ee ae 5 E rvs earve eceraresteepeted are cesar lane eae teeeereee 6 B Pawer E E E ae te A 6 E E E E reges ee asta EE 3 Instructions for users The product is registered for electromagnetic Level B compatibility for household use and can be product used in all areas including residential areas 1 Greetings x Thank you very much for purchasing of COMMAX products x Please read carefully this user manual and follow its rules x This intercom can be used in offices and shopping outlets and provide convenience to use communication on long distances i 2 Warnings and caution Please follow the things described below in order to prevent any danger or property damage Power amp Installation Warning It may cause a serious damage or injury if violated Caution It may cause a minor damage or injury if violated Please don t use several products at the same time on one power socket It m
4. Please don t insert any metallic or burnable materials into the ventilation hole It may cause an electric shock or fire Prohibition Electric shock Fire When connecting the power cables after cutting the cable please install the product with power off it may cause an electric shock or fire no Request Electric shock Fire Please avoid direct rays of the sun or heating devices at a time of installation It may cause a fire Request Overheating Fire Please use the designated connection cable within the maximum calling distance designated for the product It may reduce the product performance Request Please use only the designated batteries for the products of using DC power It may cause an electric shock or fire Ques Request When installing the product please fix it firmly while using the wall mounting unit and screws It may cause an injury from the falling object Request Please don t install the product on an unstable place or small support board It may cause an injury if it falls down while in use Request a u 3 Names and function of each part 3 1 Name of each part of CM 810M DO ofl se Oo of mwm of me PRIVACY function JKO LOCK Hands free communication TALK Conversation Call Sound Volume Control Dial MIC e e Receiver Volume Control Regulating of voice of opponent coming
5. use only one RF 1A DC12V 1A Distance 100M Holo OHM s8s10H1 It is needed to wire adaptor and first CM 810M at maximum closest way within 1 meter A distance between first and second units of CM 810M will be about 100 meters POWER 6 3 When we use two RF 1A DC12V 1A Distance 50M 100M 5 1 Wiring method This product use LINE CORD terminal for wiring 1 Terminal 10P It connects with LINE CORD 10P CONNECTOR Number of this unit will be connected to terminal L 2 ao AP i connects with LINE CORD 4P CONNECTOR La del be 3 3 3 It is recommended to use Adaptor 12V Trans Type p d It is needed to wire as closest as possible first CM 810M with power within 1 meter a ag Second and third CM 810M should be connected to each other in a 6 Power Specifications parallel way and installed in every 50 meters l 7 After installing first CM 810M unit in 100 meters distance from fourth This product s composition schema is different by distance of power CM 810M unit turn on second power supply Supply units and quantity of installing intercom units Place fourth unit of CM 810M maximum close to the power supply l unit within 1 meter 6 1 When we use only one RF 1A DC12V 1A distance 50M Place fifth and sixth CM 810M units by 50 meters distance from each other in parallel way RE ev f TA 6 4 When we use 2 pieces RF 1A DC12V 1A distance 200M a
6. A Maximum 100mA Communication Maximum 200m 20 65mm Distance 7 2 Features 1 Master between master communication 2 Nice voice quality 3 Hands free communication 4 High degree of sensitivity 5 Privacy function prevents eavesdropping from others in the intercom system 6 Offered with 3 call 5 call channels supporting up 6 or 10 stations 7 Notify you of incoming calls with an electronic tone and an LED that indicates calling station 8 Build your system with one or more master stations up to 10stations 8 a commax
7. ay cause a fire due to an abnormal overheating Prohibition Fire Please don t install the product in the place where there is much oil smoke or humidity It may cause an electric shock or fire Prohibition Electric shock Fire POBO Prohibition No disassembly No touch Must follow strictly without an exception N Warning Please don t bend the power cable excessively or it may cause an electric shock fire when using a damaged power cable Prohibition Electric shock Fire Please don t install the product with the lightening and thunder It may cause an electric shock or fire Prohibition Electric shock Fire Please don t handle the power cable with a wet hand It may cause an electric Prohibition Fire Please don t use and connect this product with other products with different rated voltage It may cause a disorder or Prohibition Fire Shows plugging out the power cord J Shows the warning and caution for an electric shock A Shows the warning and caution for a fire Please plug out the power cable from the socket when not using it for a long period of time It may shorten the product lifespan or cause a fire Request Fire When installing the product that generates heat please install the product away from the wall 10cm for the ventilation It may cause a fire due to the increased internal temperature Prohibition Fire
8. from outside e Calling Out Volume Control it regulates volume of calling sound e PRIVACY Button when this button is pushed even under communication voice of this person will not be transmitted to the other party preventing of eavesdropping is possible As CM 810M does not have a handset you should press Talk button during conversation and press again one more time Talk button in order to finish conversation 4 M commax q 4 Operational functions 4 1 Setting methods before usage and precautions 1 Setting of Melody ID lf you press for 2 seconds button sound will enter setting mode Word Sd SOUND will be shown in Display window and current number of melody initial number 01 will flicker At this moment if you press 1 or 2 appropriate melody will be in effect After melody is selected push button and finish melody selection By pressing melody selection and button device will be automatically enter to ID setting mode ID in display window and current ID initial number 01 will be sequentially flickered After setting of ID is done press and setting for use will be over beep voice will sound and bell 2 Precautions Setting of ID should be done from 1 to 10 according to wiring state n order to go over among Melody and ID setting press Example For setting only ID pressing about 2 seconds button
9. t maximum D G SM SOM Tha In case of usage of 12V 1A as it is in picture maximum 4 units will be connected Chig h hod Chi AIC hd Nae Place first CM 810M and power supply unit within 1 meter in wiring It is needed to wire adaptor and first CM 810M at maximum closest Please place first CM 810M and second CM 810M within 200M way within 1 meter _ distance and turn on the power It will possible to wire in parallel way by every 50 meters Please install second CM 810M Unit and power supply unit within 1 meter 6 7 M commax commax 6 5 When we use 3 pieces of RF 1A DC12V 1A distance 20M Make wiring distance between first unit of CM 810M and power supply unit within 1 meter Place every CM 810M from first unit to tenth unit putting them by 20 meters respectively between every unit Turn on second power supply unit connecting it to fifth CM 810M Unit which is placed in middle of this structure Wire fifth CM 810M unit by placing it from power unit within 1 meter Turn on third power unit connecting it to the last CM 810M Wire power unit with the last CM 810M within 1 meter Q7 7 Specifications and features 7 1 Technical Specifications Description Wire CM 810M 14 wires Talking 10 wires Power 2 wires L amp L1 Power Source DC12V 1A RF 1A Transmission way Half duplex communication Display Unit FND Power Consumption Stand by 50m
Download Pdf Manuals