        Extech HD200 Differential Thermometer Data Logger
         Contents
1.                 wo         4 Model HD200 Version 2 0 December 2007    IR Description   1  Laser Pointer  IR sensor  Lo Battery led  ON Scan button    2  3   4   5  Cable       IR  Infrared  Thermometer Measurement Considerations    e The object under test should be larger than the spot  target  size calculated by the  field of view diagram        If the surface of the object under test is covered with frost  oil  grime  etc   clean  before taking measurements        If an object s surface is highly reflective  apply masking tape or flat black paint to the  surface before measuring     e The meter may not make accurate measurements through transparent surfaces such  as glass        Steam  dust  smoke  etc  can obscure measurements     e The meter compensates for deviations in ambient temperature  It can  however  take  up to 30 minutes for the meter to adjust to extremely wide ambient temperature  changes     e     To find a hot spot  aim the meter outside the area of interest then scan across  in an  up and down motion  until the hot spot is located        IR measurements cannot be made through glass     IR  Infrared  Thermometer Field of View    The meter   s field of view is 8 1  For example  if the meter is 16 inches from the target   spot   the diameter of the target must be at least 2 inches     Note that measurements should normally be made less than 2 feet from the target  The  meter can measure from further distances but the measurement may be affected by  external so
2.    6  Press the Setup      button to turn on the backlight  Press it again to turn off the  backlight     7  Press and hold the Setup   button for 5 seconds to enter or exit the Setup mode   Press A to scroll to a Setup option   see  Changing Setup Options       8  Press REC     to start or stop recording  If in the Setup mode  use this button to scroll    to the Setup option you want to change  Press REC  Y to decrease the displayed  setting     9  Press ENTER to enter a Setup option  Press ENTER again to store the displayed  setting in memory     Using the thermocouple  s   1    Plug the thermocouple s  into the T1or T2 input connector s      2  Press    to turn on the thermometer  After 1 second the thermometer displays the  reading  If no thermocouple is plugged into the selected input or the thermocouple is     open   the display shows             Using the supplied IR  Infrared  Thermometer Probe    Plug the output of the remote IR probe into the T3  IR input  meter jack  see diagram      T3             will appear on screen  If the IR probe is not connected     T3            will not appear     Press the external probe   s    SCAN    button to take and display a  reading  Use the laser pointer to improve target aim     While the SCAN button is held down  the readings change as the  user scans various surfaces  When the button is released the  display is held for approx  7 seconds and the meter then returns to  poog  normal operation   888   BBB    EXTECH               
3. User s Guide    EXTECH    INSTRUMENTS          Differential Thermometer Datalogger    Model HD200             Introduction    Congratulations on your purchase of the Extech HD200 Differential Thermometer  Datalogger  The HD200 supports differential temperature measurements using dual  Type K thermocouple probe inputs and provides selectable units of   C    F or   K  The  large backlit LCD displays a versatile combination of readings  T1  T2  T3  T1 T2  T1 T3   T2 T3  plus MAX MIN AVG readings     The electronic offset feature permits compensation adjustment for thermocouple errors  and to maximize overall accuracy     The HD200 can also make non contact temperature measurements with the supplied IR  thermometer probe     The HD200 datalogger can store 18 000 measurement readings  for each channel  in  the meter   s internal memory  Stored readings can later be transferred to a PC using the  supplied PC USB interface kit  Real time meter to PC logging is also supported     This meter is shipped fully tested and calibrated and  with proper use  will provide years  of reliable service     Safety       Please read the safety and operational instructions before using this device     WARNING   To avoid electrical shock or instrument damage  do not apply voltage exceeding the  maximums specified    WARNING   To avoid damage or burns  do not make temperature measurement in microwave ovens   WARNING   Do not use the meter in any explosive atmosphere    CAUTION   Repeated flexing can b
4. activity     Press A or F to scroll to the    SLP    page    Press ENTER to show the current setting  ON or OFF     4  Press A or Y to change the setting  Press ENTER to store the new setting in  memory  On  sleep mode on  or OFF  sleep mode off      Time Setting  tiE    1  Display the time  The primary display shows the year  The secondary display shows  the month and the day  the third display shows the hours and minutes  Press ENTER  to exit the time setting option without making changes    2  Set the time  The order is year    month     day     hours    minutes  Use   C   F   K to  select a digit group  Use the A or V buttons to change the setting  Press ENTER to  store the new setting in memory     2   3     Sample Rate  rAt     The third display shows the datalogger sample rate  The default sample rate is 1 second   The third display show    00 01     The order is minutes seconds  Press   C   F   K to toggle  between minutes and seconds  The flashing digits indicate the digits ready to be edited     Press A or V to change the sample rate  Press ENTER to store the new setting in  memory     Erase the Datalogger Memory  CLR     To clear the memory  enter the CLR setup mode  press A or V until the display shows  the confirmation screen    SURE YES    and press ENTER to clear the memory     6 Model HD200 Version 2 0 December 2007    Displaying Temperature units    1  Press   C   F   K to select the desired temperature units     2  Touch the thermocouple s  to the object und
5. cts resulting from action of the user such as misuse   improper wiring  operation outside of specification  improper maintenance or repair  or  unauthorized modification  Extech specifically disclaims any implied warranties or  merchantability or fitness for a specific purpose and will not be liable for any direct  indirect   incidental or consequential damages  Extech s total liability is limited to repair or  replacement of the product  The warranty set forth above is inclusive and no other  warranty  whether written or oral  is expressed or implied     9 Model HD200 Version 2 0 December 2007    Calibration and Repair Services    Extech offers repair and calibration services for the products we sell  Extech also  provides NIST certification for most products  Call the Customer Care Department for  information on calibration services available for this product  Extech recommends that  annual calibrations be performed to verify meter performance and accuracy                                am   pa   Support line  781  890 7440  Technical Support  Extension 200  E mail  support extech com    Repair  amp  Returns  Extension 210  E mail  repair extech com    Product specifications subject to change without notice  For the latest version of this User Guide  Software updates  and other  up to the minute product information  visit our website  www extech com  Extech Instruments Corporation  285 Bear Hill Road  Waltham  MA 02451                Copyright    2007 Extech Instruments Cor
6. de to adjust the thermometer   s readings to compensate  for errors in a specific thermocouple or IR temperature  The allowable adjustment range is   5 0   C or   9 0   F     1  Plug the thermocouple into the input connector     2  Place the thermocouple in a known  stable temperature environment such as an ice  bath or dry well calibrator     Allow the readings to stabilize   In Setup change the offset until the primary reading matches the calibration  temperature    Battery Replacement   Turn off the thermometer    Slide off the meter   s rear panel    Replace the battery     POON Ss    Secure the rear panel     7 Model HD200 Version 2 0 December 2007    USB PC Software and Interface    The HD200 is equipped with a communication jack on its upper left side  The supplied  communications cable connects to this jack and to a USB port on a PC  The supplied  software allows the user to view and save readings to the PC  Instructions for use and  features are detailed in the supplied software HELP utility        s H0200  Fief  RosiTme     COMPot Date Logger Hell     us o  amp      EXTECH  gt e m RealTime Graph    e stage  Normal       Start Time    106 00     0 00    80 00    76 00    60 00    5000    40 00       1457 25 1457  145813 145837 145901                   8 Model HD200 Version 2 0 December 2007    Specifications    General Specifications    Display   IR Field of View  Datalogger memory  Memory Sample Rate  Over range indication  Open input indication  Low battery indicat
7. er test  The temperature reading appears  in the primary display   Notes       The display shows           when a thermocouple is not connected     The display shows OL  overload  when the temperature being measured is outside the  thermocouple or meter range     Holding the Displayed Readings  1  Press HOLD to freeze the readings on the display  The display shows    HOLD      2  Press DIF T1 T2  T3 to scroll through T1  T2  T3  T1 T2  T1 T3  or T2 T3 readings for  the primary or secondary display   3  Press HOLD again to turn off the HOLD function   Viewing the MIN  MAX  and AVG Readings    1  Press MAXI MIN to step through the maximum  MAX   minimum  MIN   or the average   AVG  readings  The elapsed time since entering MIN MAX mode  or the time at  which the minimum or maximum occurred appears on the display    2  Press MAX MIN button for 3 seconds to exit the MIN MAX mode     Note  Max Min Ave applies to the T1 and T2 inputs only     Datalogging  1  Set the desired sampling interval as described in the Setup Mode     2  Press the REC     button to start recording  The    TYPE K    and    IR TEMP    indicators  will flash on at the set sample rate when the meter is datalogging     3  Press the REC     button to stop recording   The supplied software allows the user to transfer stored data to a PC  Refer to the  separate software instructions on the supplied software disk for details    Using the Offset Function to Adjust for Probe Errors    Use the offset option in Setup Mo
8. es when the l    f f 1 TYPEK IRTEMP  WM  SETUP 4  meter is recording  l   i z OOOO  2  IR temperature  display flashes when the meter 11 13 m    5  recording  T2 13 ol Ll Lit       3  Data Hold mode  readings are frozen on  display     ana     ABDA        Appears when meter is in the SETUP mode 11 n 8    5  Primary Display  T1  T2  T3   T1 T2 T1 T3 or  po o    T2 T3 reading  10    mrima  m9    6  Secondary Display  MAX  MIN  AVG  offset T1   T2   or T3 reading     7  Temperature unit of measure   8  Third display  Elapsed timer or T1  T2  T3 reading  9  Low battery icon   10  Timer   11  MAX  MIN  AVG display mode icons          ana       3 Model HD200 Version 2 0 December 2007    Operation    The Basics    1  Press D to turn the thermometer on  Press and hold the D button for 3 seconds to  turn the meter off     2  Press MAX MIN to record and step through the maximum  minimum  and average  readings for the T1 and T2 inputs  does not apply for the T3 IR input   When active   the display shows the maximum  minimum  or average of the logged readings and the  elapsed time  To exit the MIN MAX AVG mode press and hold the MAX MIN button  for 3 seconds     Press   C   F   K to switch between Celsius    C   Fahrenheit    F   and Kelvin    K    Press HOLD to freeze or unfreeze the displayed readings     Press DIF T1  T2  T3 to scroll through display combinations  T1  T2  T3 and T1 T2  T1   T2  T2 T3  differential temperature measurement  in the primary  secondary and third  display  
9. ion  Power supply  Operating Temperature  Operating Humidity  Storage Temperature  Storage Humidity    Three line display multi function LCD  8 1 distance to spot ratio   Over 18000 readings per input channel  Adjustable  1per second to 1 per 59min 59sec            appears on the LCD   Mannan   appears on the LCD   Battery symbol appears on the LCD  9V Battery   32 to 104  F  0 to 40  C    10 to 80  RH   14 to 140  F   10 to 60  C    10 to 75  RH                               Dimensions 7 9 x 2 9 x 1 9   201 x 75 x 50mm   Weight Approx  9 80z   280g  with battery  Function Range Resolution Accuracy   Type K   100  C    0 1372  C  lt 1000    0 1  F C    0 15 rgd 1  C 1 8  F   See aoe 710005 TIC   0  5 rgd 2  C 3 6  F    R  cae i  ere 1  F C    2 rgd 2  C 3 6  F   Warranty       EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects  in parts and workmanship for three  3  years from date of shipment  a six month limited  warranty applies to sensors and cables   If it should become necessary to return the  instrument for service during or beyond the warranty period  contact the Customer Service  Department at  781  890 7440 ext  210 for authorization or visit our website  www extech com for contact information  A Return Authorization  RA  number must be  issued before any product is returned to Extech  The sender is responsible for shipping  charges  freight  insurance and proper packaging to prevent damage in transit  This  warranty does not apply to defe
10. poration  All rights reserved including the right of reproduction in whole or in part in any form     10 Model HD200 Version 2 0 December 2007    
11. reak the thermocouple leads  To prolong lead life  avoid sharp  bends in the leads  especially near the connector     This symbol on the instrument indicates that the operator must refer to an  explanation in this manual     im Double insulation    IR Safety Notes    e Remove the battery if meter is to be stored for longer than 60 days   e Use extreme caution when the laser pointer beam is on    e Do not point the beam toward anyone s eye or allow the beam to strike the eye from a  reflective surface    e Do not use the laser near explosive gases or in other   AEU Avon rosue         from this aperture  potentially explosive areas LASER RADIATION DO NOT STARE INTO BEAM  OUTPUT lt 1mW WAVELENGTH 630 670nm  CLASS 2 LASER PRODUCT  Complies with  FDA 21 CFR 1040 10 and 1040 11  IEC 60825 1  2001 08  Edition 1 2       EN 60825 1 1994 A11 1996 A2 2001 A1 2002          2 Model HD200 Version 2 0 December 2007    Description  Meter Description    1  Thermocouple inputs    2  PC USB interface input   3  IR probe input jack er   4  Up arrow button   5  SETUP  amp  Display backlight button ea eee  6  Down arrow and Record button 5   7  Temperature units select button   8  MAX MIN button 4   9  Display configuration button   10  LCD Display      11  ENTER button  12  Battery compartment  amp  Tripod mount  rear  7  13  Display HOLD button 8  14  Power button 9    Note  Description of IR sensor contained in later section              Display Description 2 3  1  Thermocouple type  Icon flash
12. urces of light  In addition  the spot size may be so large that it encompasses  surface areas not intended to be measured        40mm     320mm  80mm     640mm    5 Model HD200 Version 2 0 December 2007    Setup Option Mode    Entering and Changing a Setup Options    1  Press and hold the Setup button for 3 seconds to enter the Setup mode      SETUP    will appear in the upper right hand corner of the LCD                            2  Press A or Fto scroll to the desired setup option  3  Press ENTER to begin editing the selected option   4  Press Aor W to change to the desired setting   5  Press ENTER to store the new setting in memory and step to the next option  6  Press and hold the Setup button for 3 seconds to exit the Setup mode  Display Option Description  T1 T1 Offset Adjust T  offset value  T2 T2 Offset Adjust T2 offset value  T3 T3 Offset Adjust T3 offset value  SLP Sleep Mode ON  mode on  or OFF  sleep mode off   tiE Time setting Check the time or Set the time  rAt Sample rate Set the datalogging sample interval  CLR Clear Clear the datalogger memory                   Note  Setup is disabled in MIN MAX AVG or REC mode     Offset  for T1  T2  or T3     The primary display shows the actual temperature plus the offset  the secondary display  shows only the offset value  Individual offsets for T1  T2 and T3 can be stored for later  recall     Auto Power Off mode  SLP    1  The default mode is Sleep Mode ON  the meter will automatically shut off after 20   minutes of in
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Acer Professional CB280HK  スプレーガン  04598 RN master (`10-) Rueda gemela FIJA.FH11  70200131-2_Manuale J130-J214-J215-J216-J300 5 lingue  User's Manual  JVC CA-MXJD5 User's Manual  IFU-AK0024-8 Archer Universal RNA Reagent Kit  別紙 - 全国木材組合連合会  MANUEL D`INSTALLATION pour MLC 9000+  Diameter Calculator Reference Manual    Copyright © All rights reserved. 