PowerPlus XM series Modular UPS SNMP Card user manual

image

Contents

1. s i select F Fig 34 NetAgent Telnet Window 1 Set IP Address This function allows you to setup IP Address Gateway Address Subnet Mask parameters 2 Set SNMP MIB System This function allows you to set the MIB system group parameters 3 Set SNMP Access Control This function allows you to set the Manager IP Community Access Permission Note The configuration of Set SNMP Access Control is only used for SNMP Network Manager 4 Set SNMP Trap Notification lf you want to use a PC and perform the Trap function of SNMP manager to manage UPS through Net Agent the IP address of the PC must be added in this list of Net Agent Note The configuration of Set SNMP Trap Receiver is only used for SNMP Network Manager 5 Set UPS Properties This allows you to setup the Communication Type of UPS UPS Device Name and Battery Replacement Date 6 Set UPS Devices Connected This allows you to setup the System Name Rating which connected 7 Set System Time amp Time Server This allows you to setup the System date time and two time servers 8 Set Web and Telnet User Account This is allows to set users account s authority 9 Set E mail This is allows to set e mail accounts to receive power event notification for emergency management 33 a Reset Configuration to Default set all values to their default settings b Save amp Reboot Save the current configuration data including any changes
2. 26 2 2 9 Language This page is to set the language for NetAgent Interface Language This section is to set the language for NetAgent web pages When users start NetAgent in a browser NetAgent will auto detect the language in the computer system and show the same language on its web pages Users can also choose the languages they prefer from the Interface Language list Note Users will have to enable cookies before they use this function Email Preferences Tick it to apply the language preference to emails sent and SMS receipt O English O Korean O Japanese C German Portuquese Spanish O French L Italian Mote Setting preferences will not wark T you have disabled cookies in your browser Email Preferences Use below interlace language in Email and SMS notiication Chinese Simplified Apply Reset Help Fig 25 Language 2 2 8 Log Information Sub Menu 2 3 1 Event Log This page is a UPS Event log It shows a record of all events giving the Date Time of the event and a detailed description of each When reach to the limit it rewrites on the previous logs Date Time This is a record of the Date yyyy mm dd and Time hh mm ss that the event occurred Description This is a detailed description of the event __Dato Timo AAA VE 2009 01 01 00 08 58 Static Switch in Inverter Mode 2009 07 01 UU Un 5 7 Bypass Frequency Fail 20090101 UU 00 54 UFS Capacity Mormal 2009 0
3. Section1 Introduction NetAgent supports multiple Network Management systems and LAN protocols After finishing hardware installation you are now able to choose any utilities that provided by NetAgent to monitor and control UPS Here are introduction for using Telnet Section2 Telnet Configuration Select Start from Windows click Run to key in NetAgent IP Address Tepe the pame of a programe folder do cure dt hemet resource and nidos aB oper il for sg psr lelne 192 166 0 1 44 T E Fig 31 Telnet Startup Successful link up display a Felnet 194 168 0 L30 UPS SHAP figent 11 Setup Progran 7777 Mega Systen Technologies Inc Copyrightic 2886 ALL Hights Reserved Press any key to continuo Fig 32 Telnet Connection Initial to setup please press Enter to enter telnet main screen lf the User Name and Password had been set before please enter actual value to access ser Mame User Password 6 E A Fig 33 Telnet Input User Name Password 32 Main screen is as follows Telnet 1592 JAR 0 RA Hain Menu M M i A A A A A ee T Un Bet AA Set SMA AI Seeten Set HAAF Hewes Contenu Set SMAF Trap Moatifiesation Set UPS Properties BRE UPR levies Lonmeciod Set Sustem Time amp Tine TS Set Wel and Lelnet User Accuunk Set Email Reset Configqgueatian ta fief ale LE Za E d Fa b 9 hi b P C lt Seve k Hebuul kei Without Haw iig
4. from Netility to upgrade it Ze Syste Tech nutnpies PRE Internet Explarier pe Al E E hipan repeler com bD owriad Hed Hot esr 1196 bacrcr sea ej i Pf ee ga megi system r cinain s Ep G E AR gt Shipment Tracking att nant E NetAgent Firmware download procedure 1 Check your CURRENT FIRMWARE version Note 2 Locate your MODEL NUMBER shown atthe bottom of your Net gent device 3 Choose the correct firmware version corrasponding to your Model Number HOTE T pur Med gent Firmware is either VAT V2 24 012 30 you must upgrade your irmrware PROGRESSNELY h al A S alla you musi FIRST download and upgrade to V2 30 then do 2 33 and finally to WARNING Skipping one or more tinrevare versions will damage NetAgent and resultin a crash version Upgrade From WLT to 42 24 trom V2 24 16 2 30 from V2 30 10 V233 Latest version for model type CM BN A ME PK remains at v2 95 27 Latest Netagent Firmware for Version VS 37 and above Netagent Firmware Version Model Type DK CK amp BK Upgraded to V2 36 Release Date since 315 July 2008 ie Pas Pr peer raie support Release Date Sth February 2007 Release Notes FIXED email issues on v2 38 FIXED SST issue on w2 38 307 Erl 2 38 CK504 zip ma nia na 62 Internet MILLE F 0 2 Use FTP to update suitable for BK CK DK BP CP DP using firmware version 2 35 and later The FTP is an easy and common way to upload the lates
5. POWER plus 2 PowerPlus XM SNMP NetAgent User s Manual Contents Chapter 1 INFOdUCHION siii iaa ia 1 Section Felicia ads 1 SECHONZ ADDIICAUONS iuris 2 2 1 NetAgent makes your UPS on the Internet esse eee eee eee eee ee 2 2 2 NetAgent Provides Shutdown Utilities sss sees eee ee eee eee 2 Chapter 2 NetAgent UPS Installation cccoonncciconnncconcnccncncnccononnncnnnannnnnannnnnnnnnnnnaannns 3 Chapter 3 NetAgent UPS and Network Connection ssssssssssssssssssss sss ssssss esse sees e nenes 4 Chapter 4 Using Netility Setup IP Update Firmware ccccsssecssseeeeeseeeeeseeeeneeseneees 6 Section1 Install Netility conc 6 Section2 Using Nel aru ii ds 6 Chapter 5 UPS Web management by NetAdent ssssssssssssssssss sss ss esse senses 10 SECHOM 1 IA sls TR Ta Maira 10 Section2 NetAgent UPS Web Interface ccoonnccccnncccconcnccononccocncncnnnnannnnnnannnenaannnenanas 11 22 MON O Marisa dead 11 AE A A 11 o RS Ac RS a a 12 2 e UIC ML SAIS iio 13 2 D REMOIC COMM e seen e nes dec cesse ee ferment etui 14 CO Me AR ad a A 14 ER 15 22 UPS COMUGU KU cido cd acido 15 2 tie UPS OIMON SCH QUIS iaa 16 A A A 16 A de codes din ceed de ee ee de 18 O AN a Ses ne duc 22 PLAGES A OT En 24 A a ere 25 Y Ia 26 2 2 FANG A nn ae et ne 27 2 9 OG A II cn tient old 28 E O A an M nn A Nana a de 28 2 92 Dala LO rales 28 2 3 Foave Dala LOT esa ds 29 P o AP e on II EEA 30 e IEEE PE eyelet guise AEA ATALA A NE
6. m L i a he POS F F k A EE T PE mx J lu ka ri F a E TOF oo i A mi OPS of 15 Jaki C C Gl L Ia ICO 5 2 2 Small Icons Small icon view to display NetAgent UPS s IP address Name location etc CETE gom F T gt ro a S e TTS qa pa EA CIE LZ CE PE 1 8 k Era i ary F ra TE le ar Lis KRITI Sab 192 168 1143 50 5 2 3 Details Detailed Information displays NetAgent UPS s IP address name input voltage output voltage battery capacity load frequency etc E SHMPVicw CE 114 garan io Silos lan 3721681143 20752 168 1 142 CAT var Hongkong EHT ont gt a 2 7 p oad N N m m S me ACSI Conn E Z H 0 ja es EH LE LA I 5 2 4 Map Background Import a map image JPG by right click on the main screen and move NetAgent UPS icon to Its suitable location E SHMPVicwr 0 i T Mattar Ta wan TUE Honakon 0 1921687 51 5 3 Tools P Highlight NetAgent UPS device and configure 5 3 1 Settings General This to configure UPS information record UPS event enable trap alarm etc la Seltinoe 32 168 1 144 x General EMail SME Motivation Trap List UPS Loadira UPS Name UFS Age Location My Dice Manager Admine ator runiy ORE cm TA Pollina lalaa U Sue default 10 sse R becnd Bas even E t ip dala Sn Ig Perad URS Event F Enable Yamina hlesiage En
7. ClientMate Fig 36 ClientMate Main Window 35 2 1 Configuration When the ClientMate gets the signal from the NetAgent about the AC power failure or battery low signals the ClientMate will based on the configuration below to initiate the shutdown process The details of the configuration are here below Gereral bare Fabre Schedule Sudar Host Correction SHME YIAN User Hame Paad C SHMPUS ulo alio ur E r LPSilan UPS nn nes Hest 32180199 Len SAMP pare 161 Commun Hat EE RE T Brosdeset amino Massages On Serva platform dveslable List A 1 186 0 193 fd Pooup wamnobdececs Conlounshaon P sz sw od Paso Conlim d Password Fig 37 ClientMate Config i Host Connection Configure the Host connection IP address li Host Press the Query to search the host on the network automatically If a host RUPS2000 Host located on different network segment Please input the IP in the HOST edit box The IP searched on the Connect Query N The NetAgent Host S The UPSilon2000 Host ii Community Name For NetAgent only The community name of the NetAgent thus the ClientMate could be able to make connection to NetAgent iv Computer Shutdown Set the shutdown configurations v Broadcast Warning Messages On
8. If lose this password NetAgent UPS will never be able to complete any upgrade process Management Protocol NetAgent UPS provides HTTP WEB and Telnet to reference any related parameter setting for the manager Concerning with security the manager could build use openly or any advance port setting upon the above two methods Followings are the description 1 At advanced setting two functions were set as activated by using port number 80 and 23 2 Untick means not using the function 3 When set to the other port value full IP Address must be entered in order to login to the website or Telnet For example Set 81 as HTTP port number then http 192 168 0 177 81 must be typed at the web address to proceed to NetAgent UPS s website Set 24 as Telnet port number then 192 168 0 177 24 must be typed at Telnet to proceed to the Telnet screen of NetAgent UPS Comigure TP Address Advanced Metility Password Hew password Confirm password Management Protocol iw Enable HITP Function HTTP port number 1 le Enable Telnet Funct Telnet port number 1 23 Cancel Fig 7 Netility Advanced setting of NetAgent UPS 3 Firmware Upgrade NetAgent offer convenient firmware upgrade function When you are going to upgrade firmware click Download Firmware from NetAgent Setup menu click Browser select new firmware file bin and press Start Thus Net Agent s Red LED and Yellow LED flashin
9. Estimated Battery Remaining Time is invalid in the current version of software 2 1 4 Remote control The remote control functions of PowerPlus XM series have been closed in the current version of software 2 1 5 Meter Chart This page displays temperature capacity load voltage etc of the UPS by appearing with meters diagrams Ee pelar 0 Fig 16 Meter chart 14 2 2 Configuration Sub menu 2 2 1 UPS Configuration This page is to set the UPS configuration Any wrong settings will cause incorrect display values or disconnection between the UPS and NetAgent UPS Properties UPS Communication Type HagaTac Three Phase WPS Denice Marne 2 UPS Model EE WPS Voltage Rating Mi 250 0 Date of lasi battery replacement g Yr yim dl aaia WPS Hecorded WPS Data Log 1 minute Tast UPS every Hone Test UPS on Weekday Monday ka Stat Time of UPS Test hh mm Warning Threshold Value Time out after loss of connection 30 seconds Critical Load 3 90 Cntical Temperature C 70 0 Entical Capacny CN 110 Fig 17 UPS Configuration UPS Properties UPS Communication Type This section is to set up the communication interface of the UPS eg MegaTec MegaTec Three phase etc The PowerPlus XM series should choose MegaTec Three Phase Any wrong settings will cause disconnection between the UPS and NetAgent UPS Device Name UPS Model User can set these values as required UPS Voltage R
10. LU Put the NetAgent Utility CD into the CD driver And execute the SNMPView program 2 After installation there will be a NetAgent group in the Windows Start group 8 Click NetAgent gt SNMPView gt SNMPView for Windows to start using SNMPView El NetAgent Degister Se SHWPView for Vindows G SHWPView Online Help D SHMEVien Boadne MA Microsoft Visual SourceSafe PA Clientlate EN Metility ap EME Servar 7 Modbus Poll i Texas Insirunents b M LFSilon 2000 MEA 9 sR e Unonsiall Section4 Using SNMPView When use SNMP view at the first time the system will ask for input the user s name and password Please enter the default value as follows to start the SNMPView User Name Admin Password lt blank gt just press lt Enter gt After the SNMPView program start up the main windows will be displayed The left panel will list the available stations by area and the right panel will list the UPS Host Name Startup Time Manager and Location of UPS found in each station CETRO Cr Te Se eee rr 3 RI J G q Emerit eH LZ MAP E a Lil haa ia Everi iy Dsl Les aie 4 Group CO CT CE O O Later zi B E MAN COMPUIENLENIEN res L per iubea ine a LC Lens bis R kad LPG dekpu Ea ie palos lad OC eee Lis raat iris tied A romane hcnd Es Er sad tem uz E ses md I ae aiin Ba jes area al 5 0 3 UPS Soni I WS marian Per Ott
11. Loading TRES DE au ag PR T Le lnr ER Eray ms Te m r har bean made Peta Neng al Normal Powe Noma PS Baltew Voltage LIU Homa FER doy Tesi Moral Digital Display NetAgent UPS information such as input voltage output voltage temperature capacity etc in digital E UPS AUPS Agent Meier HZ9 lnests Event loa Conic now Voltage Output Vollape Input Frequency Wala ie 24 s a v 2m4 Ets 699 Hs 4 Ealer Lapa UPS Load Terpertue ie ee S ET Min 10 00 BOC 450F Mak IN 1000 s 130 E 350F HTH CS Powel Homnal or Vollage m been mande amal Ei Homa S mode 0 an Himal 55 Details Display NetAgent UPS s IP address location user manufacturer and all other detailed information UPS UPS Agent boi Jess Come Melo esta LIES Nan UPS nera LP dared 1921591194 Location bly Office bel ari eager Grir ance rice uber 7 E s Model icli MINE mar PS Marr rr M1 203 1 E appro Wok auta SDE LA Etes 22057 A curar gl e Fiegen ONE H3 Wales C E aras dl Powe Homa PAS eames made K E 1 Event Log This display event happened with date time and its description FE DPS 00P35 Agent H sle lata Daisy Event Log lGenia A AS FA azi CEE d l Li i L vinim 8 pr alr malh the LPS Aa 14111 Daub ka cli re labio Habia C art Log Batir okaga Me
12. NetAgent system information and Network settings Values shown here are either provided by NetAgent itself or they are user settings from the Configuration pages System Information This section is to show NetAgent system information Values in Hardware Version Firmware Version Serial Number System Time are provided by NetAgent itself Other values are user settings from the Configuration pages Network Status This section is to show NetAgent Network settings The MAC address is provided by NetAgent All other values in this section are user settings from the Configuration pages System informados a Sun fi a e Hardware Version HOPS 20 UPS Last Self Test Flittiwaie Version 241 OFS20 UPS Nesi Self Test serial Number 202339490451 UPS Critical Load Y System Maine WPS Agent UPS Critical Temperature 00 C System Contact Administrator UPS Critical Capacity 10 Location YN Office System Time AOE ATA 00 01 54 Uptime 00 01 37 Waning will be initiated 10 minute s before Scheduled Shutdown Event Send Email for Daily Report 10 40 Network Status MAC Address DORE OT 18 E3 Primary DNS Server 202 96 129 165 Connection Type UUE pns FullDupiex Secondary DNS Server 202 956 174 665 IF Address 192 156 0 56 Time Server 12 1688 0 234 Subnet Mask 235 235 255 0 PPPoE F Gateway 192 166 0 2 Email Server smtp 12 com Fig 13 NetAgent UPS system status 2 1 2 Basic Information This page is to show UPS basic information Values
13. OoOO O Ol Output Voltage RAST MA 2440 0240 0 240 0 Inverter oaran G No Load R amp T a HD 0 98 0 26 0 Emergency Stop No Frequency Hz 50 0 High DE Shutdown Mo Static Switch Hy pass Hypass Breaker Shindovwn No Cverlosd Shutdown Mo Inverter Output Fail shutdown Ma Grer Temperature Shutdown Mo Short Circuit Shutdown Ho Battery Status Battery Normal Battery Capacity 601 do a Low Hattery Shutdown Wo Battery voltage Cy 460 Charge Stalls Floai Charge Battery Time 20 34 00 Temperature EF 33 3 21 3 F Liane Discharge Current 598 0 Estimated Batiery Remaining 1 00 00 Damn Battery 00 00 00 Time Fig 15 NetAgent UPS Current status UPS Status This section is to show the UPS power status The abnormal status will be displayed in red when there is a power event Input Status This section is to show the UPS input status including AC Status Input Voltage Input Frequency Values here will be shown in red when an abnormal status condition occurs Output Status This section is to show the UPS output status including Output Voltage Output Status UPS Loading Values here will be shown in red when an abnormal status condition occurs 13 Battery Status This section is to show the UPS Battery Status including Temperature Battery Status Battery Capacity Battery Voltage Time on Battery Values here will be shown in red when an abnormal status condition occurs The remaining battery time should refer to Battery Time The
14. Server platform only To configure if sending the warning messages when power failed only for WinNT Win2000 36 and XP server operating system vi Shutdown Windows To configure if shutdown the Windows system when power failure vii When AC failed commence computer shutdown sequence in xx Min To configure the time delay between the AC failure and the system shutdown vill When Battery Low commence computer shutdown sequence in xx Min To configure the time delay between the Battery Low and system shutdown ix Notify Scheduled shutdown before xx Min Time before the Schedule Shutdown to make notification x Turn Off UPS For NetAgent Only Setting if to turn off NetAgent UPS AC power after system shutdown xi Turn Off UPS shutdown sequence in xx Sec Time delay of turn off the UPS power xii Auto save application files Check if to save the application files before system shutdown xiii Run Application before shutdown computer Execute the application before system shutdown 2 2 Closed Files User could review all the files closed during previous shutdown process If the Auto save application files function has been turn on in the Setting dialog the details of the closed application and files could be reviewed here loved Files Closed Application Fig 38 ClientMate Closed Files 37 2 3 About Press this button could review the version information of the ClientMate as here bell
15. you have made and reboot the Net Agent 0 Exit Without Saving Exit all configuration changes will be lost 34 Chapter 7 ClientMate Windows Shutdown Utility ClientMate is a utility for connecting to NetAgent This utility is for the Windows platform When the ClientMate get the power failure signal from the NetAgent The ClientMate will save the files and shutdown the system gracefully When the hardware installation of the NetAgent has been completed you could install the ClientMate on any of the Windows system on the network When the ClientMate detects the AC Fail Battery Low Schedule Shutdown signals from the NetAgent it will save the file and shutdown the system Please check the operation description here below Section1 Install ClientMate Put the NetAgent Utility CD into the CD driver And execute the ClientMate program After complete installation there will be a ClientMate group in the Windows Start group m Hetazent Ing ClientMate K Ta ClientMate FA Fetility i Uninstall SHS Server YU O SHMEView Y im Texas Instruments k E Acrobat Distiller 5 0 EF Adobe Acrobat 5 0 Fig 35 ClientMate Group Click ClientMate to initiate the ClientMate and start using the ClientMate Section2 Using ClientMate Please find the ClientMate main window here below press the left icon to enter the configuration dialog On the right of the window is the current status of the UPS
16. 0 22 O MAallCOAS rolas 50 de DOS AIEEE ENE ETAT E EE PE A E E ia 51 92A Map BACK sle Le T 51 29 MOS Pa lion 52 SOS A da 52 5 32 URS MONITO sere a 55 E UPS deen 57 o A A OO 58 did E VENDO i occ lada 58 542 Dala OG iteclos 58 04 SONME COON da eee ee ie 59 Oo IS A EE 60 DO GHANA 9 aS SW Ol e ress sheeted es ee 60 3 012 USE Managemen nata 60 A A eer ne a en E E oe ae eee nee ree ete ee eee 61 AAA A a s 61 TN 61 Appendix Update the firmware of NetAgent UPS cssssssssssssssessssessssseesseeseeee ennenen 62 Ill Chapter 1 Introduction Section Features NetAgent is a new generation SNMP Simple Network Management Protocol monitoring product This product is for RS232 interface UPS The communication protocol includes the RS232 MegaTec Three Phase MegaTec NetAgent provides a simple and easy installation procedure User only needs to install the software of NetAgent CD on a Windows environment to configure the IP address All the other configurations could be accomplished in a Web browser NetAgent also provides shutdown utility for different operating systems It could send out the shutdown command in different conditions These conditions include the AC power failure Battery Low Over Loading Over Temperature and scheduled shutdown User could configure these conditions to initiate a system shutdown event and to avoid the abnormal power disconnection of the system Features 1 Provide SNMP MIB to monito
17. 1 1 1 1 2 1 Large Icons eg Small lcons E 2 le a 5 5 5 5 5 5 5 5 5 5 2 View S Details Map Background UPS Settings 5 3 Tools P UPS Monitor Event pa 5 4 System S 4 2 Data Log 3 SNMP Option Change Password 3 5 User U 2 Account Management 5 6 Help H 44 5 1 ENUMERATE D Start SNMPView and press the Enumerate button SNMPView will start a search for all the NetAgent on network and list them in the main window Le HLT am TS TE i R pa al A LE EL oe ee imeni Tram LE i r E E Tea APP mara ls sst ninety d roa E TIA L La L E a Bi 1 E 1 ha hs a a a e a ar is R mt e e g da ee as 5 1 1 Enumerate When press SNMPView will start a search for all the NetAgent on network and list them in the main window 5 1 2 Add Group This is to edit or display all the group station of NetAgent under network Add UPS Grau HPS Groun Greve name ie P Enable Backarcund Man AA 5 1 3 ADD UPS Click Add UPS to enter the IP address of the UPS manually Once entered the UPS will be shown on the main list x LIFE Infermsbicr IF address Ris 2 MEL q 28 Lommunily pubis Thi UPS ea Prese UPS M Add sa bsecuent H apriza Conca 45 5 1 4 DELETE UPS Highlight the unit to be deleted from main list and right click on it to choose Delete or use click on the Delete icon from main function list Hold On Shift to select multi
18. 101 UU 06 46 UPS Capacity Underrun 2009 07 04 00 00 46 UPS communication has been established 2 009 071 01 00 00 41 UPS communication has been lost Clear Save Hele Fig 26 Event Log 2 3 2 Data Log This page is a UPS data log It records UPS Input Voltage Output Voltage Frequency Loading Capacity Temperature When reach to the limit it rewrites on the previous logs Logs can be saved in CSV format by clicking on Save Data Log Date Time This is a record of the Date yyyy mm dd and Time hh mm ss that the data was recorded The interval between every log can be set in Configuration UPS configuration UPS recorded UPS data Log Input Volt This section shows records of the UPS Input voltage readings Unit Volt Output Volt This section shows records of the UPS Output voltage readings Unit Volt Freq Hz This section shows records of the UPS Input Frequency Unit Hertz Load This section shows records of the UPS Output loading shown as 28 Capacity This section shows records of the UPS battery capacity shown as Temp This section shows records of the UPS internal temperature unit degrees Centigrade Date Tlme input Wall ET Output Vols TI Aus bng a Aye T j 1 mR 20090401 00 06 22 209 10484 172909 1 223112010201 581522083 55 1 65 1 548 1 6 3390 SF 2009 04 01 00 07 22 229 VPS eS 1 229 129 1959 1 98 126 2 96 1 55 1 F5 1 55 1 CH 333001 oF 20090101 00 06 18 2
19. 27 Ye 112231 ce VAA 12291 W 10 209p 3 Fe al CO SH 133 91 HT 2019 01 01 00 05 16 Z eed ee ce We Wee 1 0 160 289 55 1 Fei 1 50 1 A 1130 91 BT 2009 07 01 00 04 14 229 Vee WEES 2216210231 50 166 2496 3 55 EG 1 5 1 SF 15 SC 91 BT 200901 01 00 03 14 22 1079 129 1 229 1078 10759 1 989 190 2483 55 1 55 1 55 1 Sp 3331 91 SF 20090101 00 02 10 279 1229 19 2231023010231 0 1690 260p 3 55 1 55 1 55 1 CH ICO PF 200500101 00 01 07 231022316231 223122312231 9 169 2898 2 55 1 55 1 55 1 SITO 56 1 55 1 55 1 55 5 01 DT 20090101 00 00 07 24 49 14 1029 41264 208 3 Fig 27 Data Log 2 3 4 Save Data Log This function is to record RS232 UPS s voltage frequency load capacity temperature etc to save as another file for the other purpose to the manager File Download Do vou want to open or save this file Ba Name upsdabs csw a Tupe Microsoft Extel Comma Separated Values File From 192 168 0 167 es Whle tiles irom the Internet can be useful some tiles can paentially y harm pour computer IF you do not trast the source do rot open o save this file What s the isk Fig 28 Save Data Log 29 2 4 Help 2 4 1 Help Display the information about NetAgent Murat este m Sha lis Fi Lin e This page te to show MetAgent sysiem mbarmation anu Log Inferm lun Mebwork setlmos values shown here are eilher provided al by MebAgent ieellorthey are Usar ecllings trom the d Configuration pages This secti
20. 30 122 168 0 199 Firmware Upgrade Hardware Version FSU Firmware Version 2 441 DFS20 EAST MAC Address 00 035 EA D02 4C 3L Select 1 ofi Refresh List Fig 5 Netility Main window 17 Launch Device Click Launch Device or double click the NetAgent listed in the table to launch it Enter the Account Login Name and Password Login Password set earlier to login If you did not configure one then just click Apply to login 2 Network Settings Choose the NetAgent UPS from the right of the screen then click Configure would shows the following setting page IP Address Set IP address for NetAgent UPS When use at the first time please set IP address subnet mask and gateway After setting enter IP address from Telnet or Browser to connect to NetAgent s website When using DHCP or BOOTP to set up IP address IP address Subnet Mask and Gateway would receive directly by the system IF Address Advanced Address Configuration l Obtain IP address by DHCP IF Address IF Address 197 188 0 110 aubnet Mask 255 255 255 0 Gateway 132 166 U 10 Cancel Fig 6 Netility Set IP address for NetAgent UPS Advanced Advanced NetAgent UPS Setting In order to ensure the secure management of UPS Netility provides two protecting function Netility Password After password setting here there is no way to give any command to NetAgent by Netility software without user s password NB
21. 7 Were P T Save this password in your password ist Fig 11 NetAgent UPS Login dialog Section2 NetAgent UPS Web Interface Enter NetAgent UPS Web page there are 4 main function items in the first Web page 2 1 Information 2 2 Configuration 2 3 Log Information 2 4 Help Enter the main function item the sub menu items will be shown on the left side of the page When using this NetAgent for the first time please enter the Config menu item to set all the configuration items Then the UPS status could be correctly revealed by other pages NetAgant Vora Dota a revi av a System infcomation Hardware Version HOP420 WES Lac Sol Toss Firmware Voralan 2 41 DP520 WPS Most Sali Tost Sarlal Number 2325040451 WPS Critical Lead Co amp W tan Gta System Hame WPS gent WPS Critical Tamporatuira0 0 G Configuration Satan Comba ct Adninisiraior UPS Critical Capacity 10 7 Locadon hy Dfte A Syatein Thre 21040101 O15 Ups e 00 01 54 Wasming willbe initiated 10 mines belo Sckhedaled Shacdewn Even Send Email for Daily Repom 10 40 Hebe od Status Log information MAC Eddras 00 05 E401 10 E5 Primary DNS Server 22 56 129 168 E j Comacton Type i00hibps FullBuples Secondary DAS Serva TC EE 174 65 IF Addrose 192 1E6 0 66 Timo Sarre 192 166 0 254 Sabat Mask 25 254 1850 PPP ot IF Gatoway 192 168 0 2 Email Serrar amp 126 com Fig 12 NetAgent UPS web page 2 1 Information Sub menu 2 1 1 System Status This page is to show
22. Accounte 25 A Select Account SCT cam ACCOUNT Accounts Acco U nZ send Email for Daily Report h mm NES lt at it40 Send Email when Event Log overflows 100 records send Email whan Laia Log aril naz 500 records Y Rese Help Fig 21 Email Email Setting Email Server This section is to set NetAgent Email Server Sender s Email Address This section is to set NetAgent s Email address The Email must have the POP3 function Email Server Requires Authentication This section is to set whether the Email Server requires authentication Account Name This section is to set an Email account name when the email server requires authentication 22 Password This section is to set a password when the email server requires authentication Send Email When Event Occurs This section is to set NetAgent to send warning Email when an event occurs Recipient s Email Address for Event Log This section is to set Email Addresses to receive warning email sent by NetAgent when an event occurs It is valid for up to 8 Email addresses Event This section is to select events for NetAgent to send warning email Clicking on Select will open a Select Events List Event email may be selected from this list The list is the same as under SNMP setting Please refer to figure 21 Recipient s Email Address for Daily Report This section is to set Email Addresses to receive Daily Report email sent by NetAgent wh
23. ET 30 E ABDOU a a a ee 30 Chapter 6 Telnet Remote Monitoring cesses ssssssssssssssssssss sese ss esse enesenn ennenen ee 32 SCHONT Introductorio 32 Section 2 Telnet Configura ON cir iii 32 Chapter 7 ClientMate Windows Shutdown Utility sens 35 Section1 Install ClientMate ooonccconnnccoconncicocnncconcnnonencncononannnnnnnnnnnnnnnrrnnannrrnnannrnnnans 35 Section2 Using CllientMale on esse he dieineate nee 35 2 IEC O A O UE UR E EE seaside oa deteeSeceeece ety 36 22 COS Elles se 37 Z SADOU RE LR a go Ets 38 ZA EV CMI OG rain iria 38 25 IP address Ol CONMCCUON TTT 39 2 OG ele n HT 39 221 ACY SAIS ia a 39 PAS RS LS AU SR EA O E Ear 40 Chapter 8 SNMPView Windows Based UPS Management System 40 DECHON 1 ZL IMMOGU COM TT 40 Section2 System REquireMents cccsscccccssseecsesseeceenseeceeseeeeenseeseessessenseessonseesees 40 Sections Instal SNMPV IO Winnie 42 Section4 USING SNMP ViCW corria ni iii 42 Section5 SNMPView Buttons sss sssss sss ss cesse cesses ess sese ennenen nenen ennenen 43 5 ENUMERATE D spa T ee eer ete 45 D N MIMIC TANG ne eee santa one dates ses dd de state sc tte ete 45 D CODE taste E EE 45 SAS 2B BELG TT 45 51 DELETE DUES ee een ee 46 5 120 BIOWSE DEVICE T 46 9 16 EXPO COR UU concer adi 46 Import e ele e Ni didas 47 5 1 8 Open are MVE VENT OG arta shine 48 9 1 9 Oper archive Data LO net 49 A A eet stueds tetas eee ete se 49 A E anes oe Oe eR CN eee eer 50 S2 EOC ea 5
24. IP addresses To manage NetAgent from any IP address enter into 19 Manager IP address Community This section is to set a Community name for NMS The community name has to be as the same as the setting in NMS Permission This section is to set authorities of administrators Options are Read Read Write and No Access Description This section is for an administrator to make notes Trap Notification Receiver IP Address This section is to set receivers IP address for receiving traps sent by NetAgent It is valid for up to 8 IP Addresses Community This section is to set a Community name for NMS The community name has to be as the same as the setting in NMS Severity This section is to set Trap receiver levels There are three levels of Trap receiver Please refer to NMS manual for Trap levels e Information To receive all traps e Warning To receive only warning and severe traps e Severe To receive only severe traps Accept This section is to set to receive a trop or not Description This section is for an administrator to make notes Event This section is to select events for NetAgent to send traps Clicking on Select will open a select Events List Event Traps may be selected from this list Events list is below The Schedule Shutdown Event UPS entering Test mode UPS entering Sleeping mode Turn Off UPS are invalid in PowerPlus XM series of current softwar
25. NetAgent UPS LA 192 160 1 5 bier ac keue Ton section F E N TET He TE etsicr Ci as i sep 192 rec l YS wd mer FRET 5 1 5 Browse Device Highlight the unit to be browsed and click it to enter NetAgent s webpage 5 1 6 Export Configuration This is to save the NetAgent UPS s configuration SnmpDLog det Jia SampEloo da la SYMPFAAME DAT llel SampLIPS Tree dat 46 5 1 7 Import Configuration This is to import the configuration of NetAgent UPS that saved L adt vy K i E LIT an 5 92 1681 node annectio 085197 1681 Hetim Waning 47 5 1 8 Open archive Event Log Open up SnmpElog dat SNMPView would show the event log of all NetAgent UPS magwa en la SrmpELog dat 11 1681 144 ENE ETE Resta er he comimunicaci n milh the LIPS 48 5 1 9 Open archive Data Log Open up SnmpDlog dat SNMPView would show the event log of all NetAgent UPS Ero poe a H Pe ate i eT T ar C AHH d LUES Hal Na Starup Input 1192168 UPS 4 21085 2084 no ES 192 168 UPSAg 2008 5 2024 2084 A 10011 1000 350 5 1 10 Quit Exit SNMPView 49 5 2 View S This is to choose the presentation format of NetAgent UPS 5 2 1 Large Icons Large icon view to display IP address and its location ET EE ES RS EEE E EAT j i SITE ai Cr a dR gt E se ONMPView k T a
26. Password Send SMS When Event Occurs YES T Events Cellular Phone number 1 0144456789 Callular Phone number 2 g Seleci Cellular Phone number 3 E j Cellular Phone number 4 Select Cellular Phone number 5 PL Select Callular Phone number E Salac Cellular Phone number 4 Selec T Collular Phone number 2 Select Apply Reset Help Fig 22 SMS 24 2 2 7 WEB Telnet This page is to set up the User Account in NetAgent User Account User Name This section is to set a user name for NetAgent web pages It is valid for up to 8 users Users have to input the user name to get access to NetAgent web pages from a web browser Password This section is to set a password for NetAgent web pages Users have to input the password to get access to NetAgent web pages from a browser Permission This section is to set user s authorizations of Read or Read Write IP Filter This section is to set a particular IP address Users can only gain access to NetAgent web pages if they come from this IP address If you want to manage NetAgent from any IP address you can set it as User Name Password Permission IP Filter ReadAWrite lt SS SS 1 No Access w A A l Ma Access No Access v Le aos CG Mo Access M e s nn U Il QU e 9 r ENEE Fig 23 WEB T
27. able Broadcartag Waring Mersaze orl bor Ur 2000 lt P TH UPS de a 3Phase UPS Cancel Email Send email notification when event occurs Sender Display name Please enter sender display name Sender email address Please enter sender email address 9 SMTP server address Enter SMTP address IP address or domain name Server requires authentication Click Setting then enter your Account Name and Account Password Notified Email Address Click add and enter new email address 52 en Settings 192 168 1 144 Gener EMail SMS paid Trap a LIPS Loading Message Sender Infomation IZ Enable Etal Sender isplay N arne Megatec Sender Email Addes s megalsc omega ec com bva SMTP Server Address megatec com ti Iv Server Require authenticator Setting Moified E mail ddess Fower abnormal condor All Event L ee E a E 1 1 megalec com Hd C Ze WOnne 0a6C com H SMS Notification Send SMS when event occurs Gettings l 92 168 1 144 x General EMail SMS Notification Trap List LIPS Loading Iw Enabk Device SMS Notification fae phone Number AC Failure 0512345678 UPS Battery Low EE AC Powe Resored Aecoveed from Low Date Impending Scheduled Shutdown UPS Failure Lost communication with UPS Restore communication with UPS Lost Gommunicalion with N elek Restore commu
28. ating V Please refer to the UPS manual to set the value Date of last battery replacement yyyy mm dd This section is to record the date when the UPS battery was last replaced UPS Recorded UPS Data Log This section is to set how often the UPS data should be logged Test UPS The Test functions of PowerPlus XM series have been closed in the current version of 15 software Warning Threshold Value Time out of after lost of connection This section is to set a period of time after which NetAgent will send a disconnection warning message This warning message will be sent after NetAgent has lost contact with the UPS for the time specified Critical Loading This section is to set the UPS critical loading shown as NetAgent will send a warning message when the UPS is overloaded Critical Temperature C This section is to set the UPS critical internal temperature NetAgent will send warning messages when the UPS overheats Critical Capacity This section is to set the UPS critical battery capacity shown as NetAgent will send warning messages when UPS low battery occurs 2 2 2 UPS On Off Schedule The UPS On Off Schedule functions of PowerPlus XM series have been closed in the current version of software 2 2 3 Network This page is to set NetAgent Network settings IP Address IP Address This section is to set NetAgent IP address Subnet Mask This section is to set NetAgent Subnet Mask Gateway This se
29. ccount name that you have created with the selected DDNS provider Login Password Enter the Password you have assigned to your DDNS Account Use external STUN server to get Public IP to register Choose Yes to ensure that NetAgent uses the WAN Public IP to update the selected DDNS server PPPoE Use this option to allow NetAgent to connect to the Internet directly using your xDSL modem Once set up NetAgent will connect directly to the Internet without going through a router The LCD will display the current WAN Public IP instead of the LAN IP Address When Connection should be made This is to set if use PPPoE to connect with NetAgent UPS Disabled Default setting Connect always NetAgent will automatically dial up and maintain continuous 17 connection Login Name Enter the login name assigned by your ISP Login Password Enter the password assigned by your ISP IP Address 792 169 0 09 Subnet Mask 255 255 255 0 Gateway 192 166 0 2 Obtain an IP address Manually w DNS Server P Primary DNS Sorar IP 1685 55 11 Secondary OWS Serer IP Ethernet Connection Type Auto Sense od stop UPS communcation when Ethemet disconnected o 1 es Dynamic DNS Services Provider Domain Hame Login Mame Login Password K Use extemal STUN serrer to get Public IP to register vas lt l Primary STUN Server IP E7 163 14267 secondary STUN Server IP Disabled Login Mame Wh
30. ction is to set NetAgent Gateway Obtain an IP address This section is to choose to set NetAgent IP address manually or via DHCP The above 4 sections can be set in Netility as well NetAgent will reboot after any of the above are changed DNS Server IP Primary DNS Server IP This section is to set NetAgent primary DNS Server IP address 16 Secondary DNS Server IP This section is to set NetAgent secondary DNS Server IP address NetAgent will use the secondary DNS Server IP address when the Primary DNS Server IP address is not working Ethernet Connection Type This section is to set communication speed between NetAgent and Network NetAgent will reboot after Connection Type is changed Stop UPS communication when Ethernet disconnected This section is to set if stop UPS communication when NetAgent disconnects with Ethernet Dynamic DNS This is a free service that allows the user to alias a dynamic IP address to a static hostname Services Provider NetAgent can be configured to register with any of the Dynamic DNS providers In general to register a Domain Name a Go to the DDNS provider website listed b Register a new user account and password with the DDNS provider c Choose a Domain Name to point to your current Dynamic IP d Enter information obtained in b and c into NetAgent DDNS fields Domain Name This is the Domain Name you have created from the above selected DDNS provider Login Name This is the Login A
31. e eer Bee beeen BARI OMT O LER las keer ler el BLETE in Eha bek a e keed Pan on Shows that the device is a UPS Shows that the UPS is Battery Low Shows that the UPS is Disconnect Off Line 42 Section5 SNMPView Buttons When use SNMPView configuration could be done by all function icons displayed or right click on the mouse to show functions list A J lt l settings Moniko Thei Eent Log paa L UU Cintions Enumerate 4cc UPS Delete UPS Ground Followings are the explanation of each function icon search all SNMP hosts that supports Public group and display them on Enumerate the screen Add UPS Manually add a host into the window Delete UPS Manually delete a host into the window Group Shows the Main group windows Settings lf the host is a UPS just click on it to view and modify the UPS s general information Monitor lf the host is a UPS just click on it to start monitoring UPS View Display in either Large icons small icons or details Event Log Records the UPS date time and description of an event Data Log Records data of all UPS listed Sets the SNMP Parameter for community Trap port and UPS SNMP Options port 43 Following is the main function icons and its reference chapter 5 1 1 Enumerate 2 Add Group 3 Add UPS 4 Delete 5 Browse Dev 5 1 Device D A Open archive Event Log Open archive Data Log 1 1 1 1 1
32. e version 20 UPS Fverts Schedule Shutdown Event UPS Failure oo a LPS enienng Test mode O O UPS emenno Sleeping mode O G WPS Load Overrun 0 C UPS Communication Lost GO E Tum Qn UPS L O AC Power Failed UPS Battery Low UPS Temperature Overrun A a P G Ma UPS Capacity Underrun 00 1000000 Bypass Frequency Fall oy Bypass AC Abnormal es Rector Rotation Error O static Swich Mode in Bypass Mode a O Inverter Short Circuit Shutdown IO C Inverter Dvor Termperature Shutdown a O Inverter Dutout Fail Shutdown LA C Inverter L orload Shutdown a o Inverter Bypass Breaker Shutdown L O Inverter High DE Shutdown O O Inverter Emergency toprER C ce O Low Battery Shutdown fa O Select All Clear Apply Fig 20 UPS Events Ba de Device Connected This section is to set the usage power and connection status of other devices which connects to the same UPS as NetAgent uses 21 2 2 5 Email This page is to set Email details for use by NetAgent Email Server smtp 125 com Email Port 25 senders Email Address ARCE a com Email Sewer Requires Authentication YES v Account Name AB CET 25 corn Password sasssnss Send Email When Event Occurs YEE v Recipients Email Address for Event Log Account ABCH 126 com Select Account Salect Accounts o aleci account Select Accounts Select Accou mit Select berpuas PA Select E
33. elnet 25 2 2 8 System Time This page is to set NetAgent system time You can provide NetAgent with up to 2 time servers or you can set a time zone System Time Time Between Automatic Updates 12 Hours Time Server 192 168 0 254 v Time Zone Relative to GMT GNT Adjust Now gt gt Reset System Time LEN mra hh mm ss 2008 01 01 09 08 30 Auto Restart Auto Restat System for Evary 0 Disable O Minutas Apply Reset Manual Restat System A er a0 Seconds Apaly Fig 24 System Time System Time Time Between Automatic Updates This section is to set an interval for time synchronization Time Server Choose the nearest Time Server to your NetAgent location The Administrator can choose from the list of a maximum of 30 Time Servers Time Zone Relative to GMT This section is to set a different time zone for different countries System Time yyyy mm dd hh mm ss This section is to set NetAgent system time manually Set this in the format yyyy mm dd hh mm ss Auto Restart Auto Restart System for Every n Minute s Use this setting to auto restart the system at a predetermined interval The default value is set to O disabled Enter between 1 to 9999 Minute i e between 1 minute or 166 65 hour or 1 to 9999 Hour 1 hour to 416 6 days Manual Restart System After 30 Seconds Use this feature to manually restart the system NetAgent restart in about 30 seconds
34. en an event occurs It is valid for up to 4 Email addresses Send Email for Daily Report hh mm This section is to set a particular time for NetAgent to send Daily Report every day Send email when Event Log overflows 500 records select YES to have NetAgent send a warning email stating Event Log has reached 500 The data will now be purged to make room for new data Send email when Data Log overflows 500 records Select YES to have NetAgent send a warning email stating Data Log has reached 500 The data will now be purged to make room for new data 23 2 2 6 SMS When NetAgent detects UPS events it allows Short Message Signals SMS be sent and received using a GSM Modem lt requires to use remote SMSAgent to send SMS SMS Settings SMS Server SMS Server Port This section is to set SMSAgent s IP address e g 192 168 0 182 and Port Number default 80 Account Name Password This section is to set SMSAgent s account password SMSAgent webpage gt Configuration gt Web Telnet Send SMS When Event Occurs Select YES to receive SMS when an Event Occurs NO default to disable Receiver cellular number for Event Log This section is to set the recipient s mobile number total of 8 mobile numbers can be assign Selectable events list is same as SNMP webpage Refer to figure 21 UPS Event SMS Settings SMS Server 152 168 0 182 SMS Server Port pU Account Mame
35. en cocon should be made Login Password Fig 18 Network 2 2 4 SNMP This page is to set NetAgent SNMP settings so it can be used by a NMS Network Management System Eg SNMPView SNMPView can be found on the NetAgent Utility CD 18 Sy gian Mame Syetam Contact System Location UPS Agent Administrator My O ice Manager IP Address 0 Primi rl e Permission Description ex public Read rie eas public Fead write w ees publie Resi dins v S pu blic Mo Access aes public Mo Access Destination IF Address Lotus events Accept Description Events 1192 168 0 182 public Waning Yes 192 158 0 187 public Information Yes Y Select public information mo public Information Mo Select publi Information kd Mo v lect public information mo e Select public Information No T elect LO DI Cr T D D Device Rating Connected HO me MO w m NO y ET Mo 3 Apply Reset Help Fig 19 NetAgent UPS SNMP Setting MIB System System Name This section is to give a name to a NetAgent System Contact This section is to give a name to the administrator System Location This section is to set NetAgent location Access Control Manager IP Address This section is to set the IP address that the administrator can manage NetAgent from It is valid for up to 8
36. g alternative means the firmware is upgrading After upgrade completed Net Agent will auto reboot To upgrade multi NetAgent with same firmware hold on shift or Ctrl and choose the NetAgent device from Netility list Please connect to the http www megatec com tw for the latest firmware If multi upgrade select When upgrade firmware to multi NetAgent Hiriart lacio 1926091045 Doanked berad Fig 8 Netility Update NetAgent UPS Firmware 4 About Netility version examined About Netility D Hetility 4 5 Copyright C 2001 2010 Meza System Technologies Inc Fig 9 Netility version examined Refresh List Search Lan s NetAgent UPS manually Netility would search NetAgent UPS from Lan automatically or the user could search manually by click on Search NetAgent Chapter 5 UPS Web management by NetAgent Section1 Introduction After finishing NetAgent installation including hardware installation and IP setting you are now able to go to NetAgent web site to monitor and control UPS by inputting NetAgent IP address in Browser Starting the Web Brower Internet Explore Enter the NetAgent IP Address Which is setting on Netility e g 211 21 67 51 On the first screen enter the current password If no password has been set just press ENTER dd Mirail letetiect Explorer Fig 10 Input NetAgent UPS IP address Euter Melbwork Paso Ste 1927 017
37. here are either provided by the UPS or they are user settings from the Configuration pages UPS Information UPS Manufacturer HAE UPS Firmware Version VEROO1 Un U UPS Moda TEE Battery Information Date of last battery replacement Number of Batteries L Battery Charge Voltage 0 0 Rating Information Rectifier voltage 2404154 PA Bypass voltage ZA vid Tv SPA Dutput voltage 240415 SPAM Rectifier Frequency SUHz Bypass Frequency OUH Ciutput Frequency 50Hz Battery Voltage 450 Power Rating TOOK YA Connection Mode 3 IN UT Phase to Neutral Phase to Phase NumberctPhase and Mumber of Wire Fig 14 NetAgent UPS Basic Information 12 UPS Information Information about UPS Manufacturer UPS Firmware Version UPS Model are provided by the UPS Battery Information Values here are invalid in the current SNMP version of software Rating Information Values here are provided by the UPS 2 1 3 Current Status This page is to show the UPS current status Users can choose an interval from the drop down box to refresh the status readings UPS Statues UPS Norra Recti er Voltage RIST 1 240 040 0 401 U Reserwe Voltage RAST MA A0 0240 040 0 Frequency Hz1 50 0 Frequency Az 50 0 Rotation Error Mo Hypasa Frequency Nn mna Power Status Marrral Bypass 40 Power Marmal Recther Operating Wo Bypass Breaker Ln pen Input Max Line oltage Pv 240 0 Input Blin Line voltage 71 240 0 Output Stas re Stat o
38. ility if did not set anything before then enter NetAgent s default value as Account admin Neglect password ftp admin 192 168 50 179 2 ftp 192 168 50 179 when using this method to enter the follow error message will be show At this moment select Enter Identity at the top left corner of file menu Then enter admin as account name and password to re enter again PS digue TED T TH aa dL rica E eplum Ee EN Reed fo Eia Heap Ra Ld d ES e RRC U ES a dal U lt l lin eT Cr Pigi irie U Effet Maes ET 193 16 50 179 Screen i LE ces Ste Lier Alamo dren ei Lez Copy Ta Folder oaths Fic Mer 10 dah niia hs and floes 7 l iB LW ES LRR Ue wees Hao N Ue NOTE E vall r Ke WOUF pr ikar Fer ap Sr ber errr UH p Sb raa rse rem CL hE LE Tul Ms Ae 9 Tea ce Zd ne Cire a F i eJ marmo EI EE Peer SRL AA 64 Once the connection been established the following window will be display Then the user may transfer the latest firmware to here for the replacement in order to complete the updating steps Sert pr Lee d AIT Liter Mamia Gp pI ue Loo DER bin i Uze oan To Folder on Hi Fae m mi 10 d dnl ad fies and folders ke unur compiler frr ZL LRA sel hate ie RTS AS S 65
39. int User may use this method to upload the latest firmware to the remote NetAgent quit This command is to allow the user to logout with the current username account as well as close the connection of FTP For example The picture below is to upload the latest NetAgent firmware file c work netagent prjs nag 2 32 DK520 bin which is in this computer to the NetAgent UPS with IP address of 192 168 50 179 63 a CARN ERA EA pee Coonected ta L 4 108 58 1779 226 Ru leg enady for naw sar Weer 192 108 54 179 ttnone 333 admin 3231 need pascword lacs word E Port command successful Guen l ASCII mode data connection For File List 2 de ORSZA_ hin Packer toilette a 16 bytes received in A BBEceonds 16484 MAKhyutes sec 2 put t werkqetegentspeejz wag 2 32 DXC26 ban Port command success iu i QGuendine data connection For 2 32 DE526 hin 226 File received l gt 1040384 bytes sent in J E Sengondo 11 S6Kbyteu sec Fip niit aanu vurelon new type OK 3 Use IE browser to update suitable for BK CK DK BP CP DP version This method is to enter the account password and IP address of the NetAgent UPS which the user wish to update under the website column Once entered user may see the current firmware version and then please copy the latest firmware to here to complete the updating process Two method of entering 1 ftp admin password 192 168 50 179 Again the password here Is the one been set at Net
40. ion Before using the NetAgent the proper hardware and software configuration is necessary Hardware installation is to connect the NetAgent and UPS and network Software configuration includes the IP address Firmware upgrade or using the Browser or Telnet for configuration You could also install the shutdown utility ClientMate to protect your Windows operating system And also could use the UPS management software SNMP View to control and management multiple UPS on the network Connect the NetAgent UPS and Network Chapter 3 Setup the NetAgent IP address or Update firmware by using Netility Chapter 4 Using the Brower to connect to Using the Telnet to NetAgent by using the IP configure the NetAgent address of it Chapter 5 UPS settings Chapter 6 Using the shutdown The NetAgent management utility ClientMate to utility SNMPView could be used connect to NetAgent UPS to manage multiple NetAgent Chapter 7 Chapter 8 Fig 1 NetAgent UPS installation flowchart Chapter 3 NetAgent UPS and Network Connection The interface between UPS and NetAgent is shown in figure 2 The monitoring Board SNT PCB 3320 JK connected with NetAgent by ports J20 ONT PCB 3320 JK Fig 2 UPS External Interfaces To UPS L To LAN Status LED LAN Port LED Light signal application of NetAgent Status LED Light Color Signal definition Condition description On Normal power Connection state with UPS Flash no con
41. nection with UPS Orange Correspondence state Light flashes when NetAgent transmits command to UPS Light signal application of NetAgent LAN Port LED Light Color Condition description Green On Internet correspond speed is 100M Flash Data transmmiting On Internet correspond speed is 10M Flash Data transmmiting Fig 3 NetAgent Out looking Yellow Install the NetAgent with UPS and Network as follows 1 Connect the NetAgent Adapter to LAN using the appropriate UTP port 2 Connect the specified serial cable W304 from NetAgent Adapter to the serial port of UPS 3 The connections of NetAgent reference to Figure 3 when UPS connect to AC Chapter 4 Using Netility Setup IP Update Firmware Section1 Install Netility Insert NetAgent Utility CD to the CD ROM driver and execute Netility exe 2 After complete installation there will be a Netility group in Windows Start gt Program Group It a NetAgent fa SNMP Vie Fig 4 Netility Group 3 Click Netility could initiate the Netility and enter the mail window for configuration Section2 Using Netility The main window of Netility is here below right table is to show you all of NetAgent be searched in LAN left side is function selection menu YNetility Launch l Web Uter Interface aT aacwrk i 1 j I r 6 i TS Search for devices LAN IP Serial Number MAC Address IP Address 3926019132 DO 03 FA 02 40
42. nication fora Metwerk reg 53 Trap List Double click on the trap that listed and configure Settings 192 1681 144 General E Mail CHE Hoihestia ap LE upp Loading TRAPL Ferme Commun Severity Eos la anar publi indien H Trap S cta Bl J 0 0 0 L cuble lroet Gn Ho Tian REG 30 0 0 cibles lrroaret Cn Hic 5 OOO public Information Ho Index b Son ouble lroet rr Ho ii U U UL public Information Ho pa 0 0 0 0 cuble Information Ho Fecsiver F lo 00 0 Corimunity public Heverk Information Masimum E Tap Hecender io the lic Dcublecies the ikem for motif UPS Loading To configure all the other devices and its load that connects with NetAgent UPS Double click on the device listed and configure Seltinga 192 168 1144 Device Intormaton 2 U Fo r 0 Ho EEE 4 U Ho Index q 4 Hame be Batis in Erable device Disable Cane Df Cancel M avr deves in He dst Coub ecick ihe ile le edit the lormation 54 5 3 2 UPS Monitor Highlight NetAgent UPS device and configure Or right click on the highlighted device and click on monitor device Meter Display NetAgent UPS information such as input voltage output voltage temperature Capacity etc in diagram E UPS UPS Agent Meter Digital pess EvertLoo l Corel Input otage Ouiput Yokaos Lap ach UPS
43. on ls to show NetAgent system information vales in Harhwers Versionfhrrwsre Version sens Mumbersvastsn Time are provided by Matkgqent itself Cher values are user sellmgs from the Conhgquratian pagas This section js ro 3 how Net gem Mebwork settings The MAC address is provide oy Met4gent A other values in this section are user settings from the Conti quration js ES hal Interner Fig 29 Help 2 4 2 About Firmware W ersion 2 41 DP520 Hardware Version HOPS0 senal Number 2925940451 Save Restore Settings Save current Configuration Restore prewous configuration s AA Reset to faciory default Mega System Technologies Inc Tel PPE 2 6 792200 Far 00 21 52 OB E maillnetagent megatec corn by Update Firnware NIT H han megat er Corn lu Fig 30 About About User may check NetAgent s instruction version of software hardware manufacture etc from here Save Restore Settings Click Save to save the configuration to your PC The text file will have a default format of YYYY MMDD_ cfg Administrator permission required Use this function to restore a cfg configuration that has been saved earlier Click Browse to the location of the file and 30 click Restore Reset to factory default This function will reset all settings to its default value Update Firmware This function will help you link to MegaTec s Web server in order to download the latest firmware 31 Chapter 6 Telnet Remote Monitoring
44. ondition 2 8 Status history In the right lower corner of ClientMate the Status History showing all the network status and UPS status happened EEPL 3 4 3 30 Connection to UPE celia ns 12 13 30 1924680155 connected cant T M Chapter 8 SNMPView Windows Based UPS Management System Section1 Introduction SNMPView is a software to remotely monitor and control multiple UPS connected to a network When an event occurs SNMPView can be programmed to send an email or a pager to inform the designated network manager It can also inform the user of the UPS current condition or configuration send a history file and more SNMP View features LU A windows interface that is simple and user friendly 2 Automatic detection and identification of any UPS with NetAgent connected to a network 3 Capable of simultaneously monitoring up to 1 000 UPS 4 Remotely control monitor and manage the networked UPS 5 Able to simultaneously support both RS 232 Interface 1 or 3 phase UPS 6 UPS condition displayed in either a graphic or analog bar chart Supports MegaTec s SNMP Agent and SNMP Internal Card Able to send email for notification Able to send SMS for notification Section2 System Requirements LU LAN WAN network system with TCP IP 40 2 RS 232 Interface UPS 8 External SNMP Agent or SNMP Internal Card 4 Microsoft Windows 95 98 NT 2000 XP Me 2003 41 Sections Install SNMP View
45. owed ClientMate Version 5 4 Meza System Technologies Inc Copyright 0 2010 2 4 Event log Fig 39 ClientMate About Press this button could review all the network status and UPS status happened Shown as below ANUBIS 1102451 06 018 11 41 59 008 084 11 4200 060921 11 42 00 Al 114200 AULT 11 49 59 0060521 11 45 59 A006 09 21 11 50 11 0060021 11 50 11 ABD 21 150031 2006 08 21 11 50 34 2006 087271 11 51 33 ma Host addiece 0 0 0 0 192 166 U 156 19 168 015 142 168 075 Te TES 135 142 169 U 155 192 TEH 156 192 71 62 0 TBC 12 1 66 0 156 192 168 0 156 192 168 0 156 192 762 0 156 R m Hest disconnected Th conmecting to Host Lost connection to UPS Connection to UPS recovered Host connected Lost connecion to UFS Heat disconnected Connection to UPS recoyensd Hoel connected AL Failure attendonl UFS Battery Low Luctern shutdown Fig 40 ClientMate Event log 38 2 5 IP address of connection Status ICON Descriptipn Already connect to NetAgent UPS at IP 192 168 0 199 Does not connect to any NetAgent 2 6 AC power status Status ICON Descriptipn The connected NetAgent UPS AC power is normal The connected NetAgent UPS AC power is failed 2 Battery status Status ICON Description The connected NetAgent UPS battery is in normal condition 39 The connected NetAgent UPS is in battery low c
46. r amp control UPS 2 Auto sense 10M 100M Fast Ethernet 3 Manage and configure via Telnet Web Browser or NMS 4 Support TCP IP UDP SNMP Telnet SNTP PPP HTTP SMTP Protocol 5 Providing easy setup and upgrade tools via MS Windows just a few seconds to finish IP setting about 1 5 minutes to upgrade firmware 6 Send both of SNMP TRAP and E mail for events notification 7 Auto email daily UPS history report 8 Send SMS for events notification 9 Matches with shutdown software to protect computer s file saving and shut down safely Section2 Applications 2 1 NetAgent makes your UPS on the Internet When the UPS install the NetAgent the system manager could check each and every UPS condition by a computer with Browser installed The manager could monitor and control the UPS by simply input the IP address of the NetAgent which connects to the UPS When there is a power abnormal condition happened the NetAgent could also send the trap information to the system manager to take proper action 2 2 NetAgent Provides Shutdown Utilities When a computer on the network with the NetAgent utility installed it could locate all the NetAgent on the network When the UPS of this NetAgent is in AC failure condition or Battery Low condition the operating system could close all the files on the system and perform a gracefully shutdown This could avoid system corrupt when a power disconnection happened Chapter 2 NetAgent UPS Installat
47. rd to login 5 5 2 User Management This is only for Admin user to add edit or remote other users info Use 60 5 6 Help H Display the current SNMPView version and operation information 5 6 1 HTML Help This is to check the operation of SNMPView E ATM DIG a fe 3 LIR nz LH FIED aw AC ian wee TI Megolec GUA Das EEE R EAA FR Megate de 3 Using D SNMPViow PET Buttons 5 Erumerata Addie A er ihe SNMP YEW program star luo ihe main windows will be 8 Daata LPS displayed The eh panel wil isl ihe avatable stations by area 15 SOLA and the righi panel will isi the UPS Host Name Startup Time E Settrigs Manager and Location of LES found in each station la Mon for LE Tew le Event Log R Data Log S Option aj henu 5 6 2 About Display the current SNMPView version Copyright information and product service contact About SHMP View Nerin 45010 Copy E 2001 2003 MegaTec System Technologies mu License dd dd For more intormation please send email to servcetaimegatec com he For product service on SNMP ew 61 Appendix Update the firmware of NetAgent UPS NetAgent provides the following convenient methods for user to update the latest firmware of the NetAgent 1 Click firmware upgrade under About of NetAgent webpage and it would link to MegaTec s server to download the latest firmware Then use Download Firmware
48. rrnal 7 5 Tesi Home Communication haz ee r rna cla Batley Hommel Control The functions of PowerPlus XM series have been closed in the current version of software Test Control The functions of PowerPlus XM series have been closed in the current version of software Turn Off Parameters The functions of PowerPlus XM series have been closed in the current version of software Test Period The functions of PowerPlus XM series have been closed in the current version of software 56 5 3 3 UPS Management To configure SNMP of its NetAgent UPS UPS Management LIPS Er UP SIdert El Basic UPS as el ert unz N ame X Smart ES Fl UPSBetlery UPSInput re UPS utp ay 5 4 System S To view event log data log and configuration 5 4 1 Event Log Display event log date time and description of all NetAgent UPS 5 4 2 Data Log Display input voltage output voltage frequency load etc of all NetAgent UPS uane uN 1 w ge SL E MER 00 E 2 HSE 168 UPS da SN EST ONE pue tie A me CRE Cl i Ti SE 0 im 182153 UPS Ag SM aed a O las ie C ala GROS S 09 A ne E EE an E GS a 58 5 4 3 SNMP Option To set NetAgent UPS s parameter Options 59 5 5 User U Total of 8 users account can be created to manage and control its NetAgent UPS 5 5 1 Change Password To change existing user s passwo
49. t firmware into the NetAgent Please follow the instruction below to update the firmware If there is other FTP client application on your computer that will also be fine to use it for updating the firmware For example if wish to update the latest firmware of the NetAgent UPS which IP address is 192 168 50 179 then please operate with the steps below 1 Enter Windows then type ftp 192 168 50 179 under Run of the Start Menu Ron ee Typethe name of a program folder document or Internet resource and Windows will open it For you Ok Cancel Eros 2 After executed the systems will requests for the user name and password Please enter admin under the user name and enter the password that was been set at Netility under password If did not set before then please enter the default value as user name admin and nothing under password press Enter Once the account and password been checked the server will response with 230 OK to indicate Login succeeded If entered wrong account and password the server will response with 530 Not Logged in to indicate Login failed 3 Operation commands as followings 1s This command is to request server to list up all the file and sub file under current Menu User may finds out the firmware version of the NetAgent UPS of its IP put lt client s file route gt This command is to ask the client to copy its specific file route to the server po

Download Pdf Manuals

image

Related Search

Related Contents

La marque Charte Ambassadeur  1. - Dazadi.com  Ear Thermometer Instruction Booklet  Thermaltake Bottom Chassis fan Xaser VI User's Manual  取扱説明書  Evaluation de la licence professionnelle Gestionnaire-export  KRT2 Manuel d`installation et d`utilisation  Philips Sonicare DiamondClean Standard sonic toothbrush heads HX6062  