Home

Z8 Encore! XP F64xx Series Flash Microcontrollers In-Circuit

image

Contents

1. NOT USE IN LIFE SUPPORT LIFE SUPPORT POLICY ZILOG S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS PRIOR WRITTEN APPROVAL OF THE PRESIDENT AND GENERAL COUNSEL OF ZILOG CORPORATION As used herein Life support devices or systems are devices which a are intended for surgical implant into the body or b support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in a significant injury to the user A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system or to affect its safety or effectiveness Document Disclaimer 2007 by Zilog Inc All rights reserved Information in this publication concerning the devices applications or technology described is intended to suggest possible uses and may be superseded ZILOG INC DOES NOT ASSUME LIABILITY FOR OR PROVIDE A REPRESENTATION OF ACCURACY OF THE INFORMATION DEVICES OR TECHNOLOGY DESCRIBED IN THIS DOCUMENT ZILOG ALSO DOES NOT ASSUME LIABILITY FOR INTELLECTUAL PROPERTY INFRINGEMENT RELATED IN ANY MANNER TO USE OF INFORMATION DEVICES OR TECHNOLOGY DESCRIBED HEREIN OR OTHERWISE The information contained within this document has been verified according to the general principles of elect
2. easy for you to set and read emulator register con tents With the ICEDEMO project open and ZDS II connected to the emulator target select View gt Debug Windows gt Registers In the Registers window double click the value of any register and type in a new value Press Enter The new value displays in red Refer to the ZDS IJ Z8 Encore User Manual on the ZDS II CD ROM and the ZDS II online help for further information on setting and reading register values Peek Poke Memory 1 UM016804 0208 ZDS II also allow to set and read memory contents With the ICE DEMO project open and ZDS II connected to the emulator target select View gt Debug Windows gt Memory 18 In Circuit Emulator User Manual z lo dq Sete 19 2 Inthe Memory window double click the value you want to change and type in a new value Values begin in the second column after the Address column 3 Press Enter The new value displays in red Refer to the ZDS IJ Z8 Encore User Manual on the ZDS II CD ROM and the ZDS II online help for further information on setting filling and reading memory LED Indicators There are three sets of dual LED indicators on the Z8 Encore XP F64xx Series ICE see Figure 2 and Figure 5 Dual LED D1 on the front panel indicates emulator status If the top LED is lit the emulator is functioning normally If the bottom LED is lit the emulator is not functioning properly Cont
3. input for an external 3 3 VDC trigger in allowing use of an external trigger as an event for the ZDS II trace and event system How to Set Connector J11 Pin 1 External Trigger Out To use the Z8 Encore XP F64xx Series ICE external trigger out feature 1 UM016804 0208 With the ICEDEMO project open in ZDS II as described in Running a Sample Project on page 14 select Tools gt Trace and Event Sys tem In the Trace and Event System window select an Event entry and specify the event parameters in the When section In the Then section of the Trace and Event System window check the Trigger Out box to enable the Toggle and Pulse settings Select the radio button for the Trigger Out setting you wish to use Click the OK button to set the trace and event system parameters When the event you set up occurs pin 1 of connector J11 either tog In Circuit Emulator User Manual Z rlan rt Zi l LJ J t E Y W 7 23 2 gles changes state or pulses depending on what you specified for Trigger Out How to Set Connector J11 Pin 3 External Trigger In To use the Z8 Encore XP F64xx Series ICE external trigger in feature 1 With the ICEDEMO project open in ZDS II as described in Running a Sample Project on page 14 select Tools gt Trace and Event Sys tem 2 Inthe Trace and Event System window select an Event entry In the When section check the Trigger In box 3 Inthe Then section set the p
4. to a custom target select the voltage appropriate for that target Note The emulator s voltage comparator is designed as a target power sensor not as a precision voltage measurement device If you set the Target VCC to match your target and the target 5 voltage drifts downward the power sensor may no longer detect it The emula tor may therefore not connect to the target In such cases set the Target VCC voltage progressively lower until you get a good con nection UM016804 0208 Note Note In Circuit Emulator User Manual 8 Select the appropriate clock frequency or enter the clock frequency in the Other field This should match the 20 MHz Clock Oscillator on Y4 of the emulator The emulator clock cannot be supplied from the Target application Board 9 Click OK to close the Z8 Encore Emulator dialog box 10 Click OK to close the Project Settings dialog box 11 Open the Trace window by selecting View gt Debug Windows gt Trace 12 Make sure that the Event System is disabled The Edit gt Event Sys tem command does not have a check mark to the left of the com mand 13 In the Trace window click the Clear Trace button 14 Build the project now by selecting Build gt Build or by pressing F7 The following steps describe two ways to use the trace and event system For details on running the trace and event system refer to the ZDS II online help and the ZDS II Z8 Encore User Manual
5. K RR KK KK 17 Single Stepping Through a Program 0 eee eeu 18 Peek Poke Registers iis cc aig ceded ee eed nee nl deyek ceeded eee 18 Peek Poke Memory kk kK cece KK KK KK KK KK KK KK KK KK KK 18 LED Indicators pce saan ee eed herent ahenrwi se mebaeeek ainda 19 External Interface Connectors 0 0 KK KK KK eens 20 How to Set Connector J11 Pin 1 External Trigger Out 20 How to Set Connector J11 Pin 3 External Trigger In 21 Adapter Ordering Information La kk KK KK KK KK KK KK KK KK eee 21 Customer Support k kk kk kk kK kk kk kk es 23 UMO016804 0208 Table of Contents In Circuit Emulator User Manual z lo dq Introduction The Zilog Z8 Encore XP F64xx Series In Circuit Emulator ICE pro vides Z8 Encore XP F64xx Series MCU emulation with a trace and event system for program debugging using ZDS II development tools This user manual tells you how to do the following 1 Install ZDS II software 2 Configure the Z8 Encore XP F64xx Series ICE for connection to your PC 3 Connect the Z8 Encore XP F64xx Series ICE to a target board using a Z8 Encore XP F64xx Series MCU package adapter 4 Runa demonstration program to verify proper operation and illustrate basic operation of the trace and event system Kit Contents One 1 Z8 Encore XP F64xx Series In Circuit Emulator e One 1 DB9 to DB9 serial I O cable e One 1 CAT 5 crossover ca
6. P Properties dialog box appears Figure 9 UM016804 0208 In Circuit Emulator User Manual Zilog Internet Protocol TCP IP Properties General You can get IP settings assigned automatically if your network suppots this capability Otherwise you need to ask your network administrator for the appropriate IP settings Qbtain an IP address automatically G Use the following IP address IP address 192 168 Subnet mask 255 255 Default gateway Use the following DNS server addresses Prefered DNS server Altemate DNS server Figure 9 The Internet Protocol Properties Dialog Box 5 Enter values for the IP address and subnet mask to match those shown in Figure 4 Leave any remaining fields blank In this example an IP address of 192 168 1 21 and a subnet mask of 255 255 255 0 are being assigned to the PC These values place the PC on the same net work as the Z8 Encore XP F64xx Series ICE unit 6 Click OK and restart the PC Refer to Changing Z8 Encore XP F64xx Series ICE Settings to Match the PC on page 12 for informa tion on checking the Z8 Encore XP F64xx Series ICE IP address 7 Proceed to Running a Sample Project on page 14 In Circuit Emulator User Manual z log Changing Z8 Encore XP F64xx Series ICE Settings to Match the PC 1 Connect the PC serial port to the Z8 Encore XP F64xx Series ICE serial port using the DB9 to DB9 serial cable 2 Launch HyperTer
7. Zilog Z8 Encore XP F64xx Series Flash Microcontrollers In Circuit Emulator User Manual UM016804 0208 Copyright 2008 by Zilog Inc All rights reserved www zilog com In Circuit Emulator User Manual ii Revision History UM016804 0208 Each instance in the Revision History table reflects a change to this docu ment from its previous revision For more details refer to the correspond ing pages and appropriate links in the table below Revision Page Date Level Description Number February 04 Changed product name and All 2008 used latest template Revision History In Circuit Emulator User Manual Table of Contents Introduction pn hake ines uae aie whe haw dbl park eke porns 1 Kit Contents gt i 2 eee ghee 2554 e eee eee d 1 Requirements 3 3 a 5545 5240314543 0 25124034541515 e e a 3124 4557 54 9 rao ees 2 Install the Software 2 M A kk kk KK KK KK KK KK KK KK KK KK KK KK KK KK KK kk 2 Install the Hardware kk kk kK KK KK KK KK KK KK KK KK KK KK KK KK KK KK 2 Configure the Hardware WW a kk kk KK KK KK KK KK KK K KK KK KK KK KK KK KK 6 Setting Jumpers on the Z8 Encore XP F64xx Series ICE 6 Setting Up Ethernet Communications 000 eee eee eee 6 Running a Sample Project kK KK KK KK KK KK KK KK KK KK KK KK K 14 Running a Simple Trace 1 2 0 KK KK KK KK KK KK KK KK KK KK K 16 Using Events to Start and Stop a Trace AL KK K
8. act technical support at http www zilog com for assistance Dual LED D2 on the rear panel indicates the status of internal volt ages The top LED indicates that the 3 3 VDC voltage is okay The bottom LED indicates that the 1 8 VDC voltage is okay you may have to turn the ambient lighting off to see the status of the 1 8 VDC LED If either LED is not lit contact technical support at http www zilog com for assistance Dual LED D3 on the rear panel indicates Ethernet status The top LED indicates that the Ethernet connection is live Link The bottom LED indicates that data is being transferred across the connected net work UM016804 0208 In Circuit Emulator User Manual 20 External Interface Connectors There are four external interface connectors on the Z8 Encore XP F64xx Series ICE Connectors J2 and J10 are used to connect the emula tor to the target POD and adapter board assembly See Figure 4 Connector J14 on the emulator front panel see Figure 4 and Figure 5 provides a ground connection on all three pins Connector J11 on the emulator front panel see Figure 4 and Figure 5 provides access to the following functions Pin 1 provides a 3 3 VDC external trigger out for use in triggering a device such as a logic analyzer or oscilloscope Pin 1 is under soft ware control and can be set to activate through the ZDS II trace and event system The trigger can be set to toggle or pulse Pin 3 provides an
9. arameters you want to use 4 Click the OK button to set the trace and event system parameters When the external device you are using sets pin 3 of connector J11 to 3 3VDC an event is generated in the ZDS II trace and event system Adapter Ordering Information Use the following part numbers to order additional package adapters Z8F64210100ZDP Z8 Encore XP F64xx Series 40 pin PDIP ICE Adapter e Z8F64210100ZDA Z8 Encore XP F64xx Series 44 pin LQFP ICE Adapter uses Adapters com 110 72662 10 e Z8F64210100ZDV Z8 Encore XP F64xx Series 44 pin PLCC ICE Adapter e Z8F64220100ZDA Z8 Encore XP F64xx Series 64 pin LQFP ICE Adapter uses Adapters com 110 7334 10 UM016804 0208 In Circuit Emulator User Manual z log Z8F64220100ZDV Z8 Encore XP F64xx Series 68 pin PLCC ICE Adapter Z8F64230100ZDF Z8 Encore XP F64xx Series 80 pin QFP ICE Adapter uses Adapters com 110 7405 10 UM016804 0208 In Circuit Emulator User Manual ZI Lo 23 Customer Support UMO016804 0208 For answers to technical questions about the product documentation or any other issues with Zilog s offerings please visit Zilog s Knowledge Base at http www zilog com kb For any comments detail technical questions or reporting problems please visit Zilog s Technical Support at http support zilog com In Circuit Emulator User Manual E NAN i N j ji N V Z I E N Z N Warning DO
10. ble One 1 40 pin PDIP 44 pin LQFP 44 pin PLCC 64 pin LQFP 68 pin PLCC or 80 pin QFP package adapter depending on the emula tor model you ordered One 1 target POD with ribbon cables to connect the Z8 Encore XP F64xx Series ICE to the package adapter that came with your kit To obtain adapters for other Z8 Encore XP F64xx Series MCU packages refer to Adapter Ordering Information on page 21 e Two 2 5V AC power supply and adapters One 1 ZDS II Installation CD ROM UM016804 0208 In Circuit Emulator User Manual Requirements Table 1 lists the PC requirements for running ZDS II Table 1 ZDS Il System Requirements Recommended Configuration Minimum Configuration PC running MS Windows XP SP1 PC running MS Windows 98SE WinNT 4 0 e Pentium III 500 MHz processor SP6 Win2000 SP3 WinXP SP1 e 128 MB RAM e Pentium 11 233 MHz processor 40 MB hard disk space 96 MB RAM Super VGA video adapter e 25 MB hard disk space e CD ROM drive Super VGA video adapter Ethernet port e CD ROM drive One or more RS 232 communications ports Ethernet port Internet browser Internet Explorer or One or more RS 232 communications ports Netscape Internet browser Internet Explorer or Netscape Install the Software Follow these steps to install ZDS II with the ANSI C Compiler 1 Insert the ZDS II CD into your computer s CD ROM drive DemoShield launches automatically If it
11. configuration set the PC s IP address to 192 168 1 21 and its subnet mask to 255 255 255 0 See Changing the PC s Settings to Match the Z8 Encore XP F64xx Series ICE on page 7 If working in a networked environment set the Z8 Encore XP F64xx Series ICE IP address and subnet mask to match the existing network setup See Changing Z8 Encore XP F64xx Series ICE Settings to Match the PC on page 12 Changing the PC s Settings to Match the Z8 Encore XP F64xx Series ICE After completing the following steps to change the PC s Ethernet settings proceed to Running a Sample Project on page 14 The following instructions are for MS Windows XP If your Win dows operating system is different refer to your MS Windows OS online help for details 1 Open the Windows Control Panel and double click the Network Con nections icon The Network Connections dialog box appears see Figure 6 UM016804 0208 In Circuit Emulator User Manual Zilog S Network Connections File Edit View Favorites Tools Advanced Help ay Q sak Q 2 Search j Folders E Address e Network Connections Go LAN or High Speed Internet Network Tasks E Create a new La j connection d LTEK Ethernet 10 10 View status of this connection Change settings of this connection Other Places Control Panel ke My Network Places My Documents My Computer Figure 6 The Network Dialog Box 2 In the pa
12. does not automatically launch go to the root of the CD ROM and double click the file launch exe 2 DemoShield provides several installation choices Select Install ZDS II to install now You can install other software and accompanying documentation later 3 Follow the instructions on the screen to complete the installation Install the Hardware The Z8 Encore XP F64xx Series In Circuit Emulator features an Ether net interface and an RS 232 serial port Hardware installation consists of UM016804 0208 In Circuit Emulator User Manual wu Z ILOQ E MM installing the package adapter that came with your kit into the compatible socket on a target board such as the Z8 Encore XP F64xx Series Devel opment Board connecting the emulator to a PC and connecting the emu lator to the target You may have to reconfigure network settings on the PC or on the Z8 Encore XP F64xx Series ICE before using the emulator 1 Install the Z8 Encore XP F64xx Series MCU package adapter into the socket on your target board being sure to line up the guide pins with the guide pin holes on the socket 2 Connect the CAT 5 crossover cable from the PC to the Ethernet port on the Z8 Encore XP F64xx Series ICE See Figure 1 Note If you prefer you can connect the emulator to an Ethernet hub using a standard CAT 5 patch cable 3 Connect the serial COM port on the PC to the serial port on the Z8 Encore XP F64xx Seri
13. e software project to verify proper emulator operation and experiment with the trace and event system The sample project ice demo pro is included in the ZDS II sample directory located in c Program Files ZiLOG ZDSII_ lt product gt _ lt version gt samples lt processor type gt _ lt demo name gt Start ZDS II for the Z8 Encore XP F64xx Series ICE and follow the instructions below to run icedemo pro Note In Circuit Emulator User Manual Zilog 15 The following procedures require that the emulator be connected to a target board such as the Z8 Encore F64xx Series Develop ment Board 1 CR n Select File gt Open Project gt c Program Files ZDSIL_Z8Encore F642X Emulator_4 6 x sam ples FZ8F642x_ICEDemo src icedemo pro Double click main c in the Project Files window Open Project gt Settings In the General tab verify the CPU field is set to Z8F6423 In the Debugger Select Z8 Encore Emulator and then click the Con figure Driver button The Encore Emulator dialog box appears The IP Address field dis plays a default IP address 192 168 1 50 Enter the Z8 Encore XP F64xx Series ICE IP address you configured during hardware install Leave the other settings as they are Select the Target VCC voltage If the emulator is connected to the Z8 Encore XP F64xx Series development board select 3 0V If running the emulator in standalone mode select Standalone If the emulator is connected
14. es ICE using the DB9 to DB9 serial cable See Figure 2 CAT 5 Crossover Cable PC La l 78 Encore XP F64xx Series Bu DB9 to DB9 Cable ZA ICE Figure 1 Connecting a PC to the Z8 Encore XP F64xx Series ICE UM016804 0208 In Circuit Emulator User Manual 3 3 VDC OK Link Ie LAN Ext i USB Reset 1 8 VDC Ok Pwr RJ 45 unused Switch In EEE connector Figure 2 Z8 Encore XP F64xx Series ICE Rear Panel 4 Connect the ribbon cables from the target POD to connectors J2 and J10 on the Z8 Encore XP F64xx Series ICE See Figure 3 and Figure 4 5 Plug the target POD into the package adapter installed on the target board 6 Connect a5 VDC power supply to the Z8 Encore XP F64xx Series ICE The ICE Run LED should illuminate see Figure 5 If either power LED fails to illuminate or if the ICE Fail LED either blinks continuously or fails to extinguish after 15 seconds there is a problem with the unit Contact Zilog support at http www zilog com for a replacement unit 7 Connect a 5 VDC power supply to the Z8 Encore development board UM016804 0208 In Circuit Emulator User Manual Zilog Target POD and Adapter Assembly Figure 3 Connecting the Z8 Encore XP F64xx Series ICE to the Target POD and Adapter Assembly Typical Connection Shown r a ae J2 Pin 1 eeel J14 J12 Je P
15. figuration Console Type H for help Note The emulator console prompt is not case sensitive 7 At the prompt type H and press ENTER The following message should appear gt H H display this Help I change Ipaddress S change ipSubnet mask G change ipGateway P change Portnumber V change dtli Variable count B change dtli Buffer size F load deFault settings C display Current settings D toggle Dhcp option A toggle pAssword W change passWord UM016804 0208 In Circuit Emulator User Manual oe Zilog 14 R Reset emulator gt 8 Use the I command to change the Z8 Encore XP F64xx Series ICE IP address to one that is compatible with the PC Use caution to avoid creating a conflicting IP address 9 Use the S command to change the Z8 Encore XP F64xx Series ICE subnet mask to one that is compatible with the PC Typically the sub net mask is the same as that of the PC 10 Use the G command to change the Z8 Encore XP F64xx Series ICE Gateway to one that is compatible with the PC Typically the gateway is the same as that of the PC 11 Use the C command to verify the new settings 12 Exit HyperTerminal 13 Cycle the power on the Z8 Encore XP F64xx Series ICE for the new settings to take effect The hardware is now configured and ready for application development Running a Sample Project UM016804 0208 After installing the ZDS II software and setting up the hardware you can run a sampl
16. his as the event to break the trace In the When section click the Program counter check box and set the Program Counter to 041D and the Mask to FFFF In the Then section click the Trace check box Select the Off radio button and select the AND BREAK radio button Click the OK but ton In the Trace window click the Clear Trace button Reset the Debugger by clicking the Reset button in the toolbar or by selecting Build gt Debug gt Reset Run the Debugger by clicking the Go button or by selecting Build gt Debug gt Go Wait for the program execution to break 17 In Circuit Emulator User Manual 13 Click Get Frames to display the trace information Study the contents of the Trace window to see how the trace and event system reports program execution for the segment we set using the Event tools Single Stepping Through a Program 1 ZDS II provides a simple mechanism for single stepping through a program First reset the program to Main by either the Reset icon or with Build gt Debug gt Reset Set the Reset to Main option by selecting Tools gt Options In the Options window select the Debug ger tab and select the Reset to symbol main check box To step through the program one instruction at a time use F11 or click the button in the Debug toolbar also accessible by selecting Build gt Debug gt Step Into Peek Poke Registers 1 3 ZDS II makes it
17. int au J10 Unit Front Figure 4 Z8 Encore XP F64xx Series ICE Top View UM016804 0208 In Circuit Emulator User Manual Z Lod T Te ICE Run J11 and J14 J10 and J2 J12 ICE Fail Figure 5 Z8 Encore XP F64xx Series ICE Front Panel Configure the Hardware Configuring the Z8 Encore XP F64xx Series ICE consists of selecting emulator jumper options and setting up Ethernet communications between the emulator and your PC Setting Jumpers on the Z8 Encore XP F64xx Series ICE There is one jumper on the Z8 Encore XP F64xx Series ICE Jumper J12 allows you to select whether the emulator Watch Dog Timer uses the 32 kHz internal oscillator or is programmable using the settings in ZDS II Table 2 Jumper J12 Settings on the Z8 Encore XP F64xx Series ICE Watch Dog Timer Jumper Position uses the 32 kHz internal oscillator 1 2 default not implemented 3 4 Setting Up Ethernet Communications The default IP address and subnet mask of the Z8 Encore XP F64xx Series ICE are 192 168 1 50 and 255 255 255 0 respectively To enable communication between the PC running ZDSII and the Z8 Encore XP UM016804 0208 Note In Circuit Emulator User Manual ZILODd lt a 2 F64xx Series ICE you must either change the PC s Ethernet settings to match those of the Z8 Encore XP F64xx Series ICE or vice versa If using the PC in a stand alone
18. located in the docs directory of the ZDS II CD ROM Running a Simple Trace Now we ll run a simple trace by starting the program then stopping it and viewing the trace buffer Click the Go button in the toolbar ZDS II com municates with the emulator then runs the demo program When the trace buffer is full the CPU breaks on Trace Buffer Full message displays in the Debug window Click Get Frames to display the trace information View the trace window and yov ll see that all program cycles are logged Click the Options button in the Trace window to select the way in which you d like the trace displayed UM016804 0208 In Circuit Emulator User Manual ZILOG lt a Using Events to Start and Stop a Trace UM016804 0208 1 Now we ll define a pair of events to automatically start and stop a trace Use this feature for example to trace execution of a particular module in your program and see the context in which the module is running with respect to other program modules Select Tools gt Trace and Event System Click the Enable event sys tem check box and click the Break when trace buffer is full check box Select Event 0 We ll use this as the event to trigger a trace In the When section click the Program counter check box and set the Program Counter to 03F2 and the Mask to FFFF In the Then section click the Trace check box and select the On radio button Select Event 1 We ll use t
19. minal on the PC by selecting Start gt Programs gt Accessories gt Communications gt HyperTerminal 3 Inthe Connect To dialog set the Connect Using drop down menu to match the COM port to which the Z8 Encore XP F64xx Series ICE is connected Click OK 4 A COM Properties dialog appears Enter the following port settings and click OK Bits per second 57600 Data bits 8 Parity None Stop bits 2 Flow control None 5 HyperTerminal should automatically attempt a connection If not select Call gt Connect 6 While holding down the z key lowercase on the PC s keyboard press the RESET button on the back panel of the Z8 Encore XP F64xx Series ICE Releasing the z key displays a Z8 Encore XP F64xx Series ICE console boot up message in HyperTerminal fol lowed by the gt prompt A typical boot up message is shown below 1540096 bytes physical mem RAM Block0 from 100000 to 17ffff Flash ROM from 8000 t fffff 172701 bytes Code 15947 bytes Data 321128 bytes user stack heap space Starting at 131991 UM016804 0208 In Circuit Emulator User Manual z log Zilog TCP IP Software Suite v1 1 Copyright C 2003 Zilog Inc All Rights Reserved clock enabled IP Address 192 168 1 50 IP Subnet 192 168 1 0 255 255 255 0 IP Gateway 192 168 1 254 Z8 Encore ICE Communication Module 1 0 Copyright 2001 2003 Zilog Inc All Rights Reserved Z8 Encore Emulator Con
20. nel labeled LAN or High Speed Internet double click the Local Area Connection icon The Local Area Connection Status dia log box appears Figure 7 UM016804 0208 In Circuit Emulator User Manual Zilog 4 Local Area Connection Status General Support Connection Status Connected Duration 3 days 05 55 51 Speed 100 0 Mbps Activity Received Packets 35 712 Figure 7 The Local Area Connection Status Dialog Box 3 In the Local Area Connection Status dialog box click the Properties button The Local Area Connection Properties dialog box appears Figure 8 UM016804 0208 In Circuit Emulator User Manual Zilog Local Area Connection Properties General Authentication Advanced Connect using Ep Intel R PRO 100 VE Network Connection This connection uses the following items m B File and Printer Sharing for Microsoft Networks V QoS Packet Scheduler Intemet Protocol TCP IP v gt lt Description Transmission Control Protocol Intemet Protocol The default wide area network protocol that provides communication across diverse interconnected networks C Show icon in notification area when connected Figure 8 The Local Area Connection Properties Dialog Box UM016804 0208 In the panel labeled This connection uses the following items select the Internet Protocol TCP IP item to highlight it and click the Prop erties button The Internet Protocol TCP I
21. rical and mechanical engineering Z8 Z8 Encore Z8 Encore XP Z8 Encore MC Crimzon eZ80 and ZNEO are trademarks or registered trademarks of Zilog Inc All other product or service names are the property of their respective owners UM016804 0208 24

Download Pdf Manuals