Home
GM10 Firmware Upgrade Procedure
Contents
1. Example with Internet Explorer 8 and 9 Click Tools gt Internet Options to open the Internet Options properties On the General tab under Browsing History click the Delete button The Delete Browsing History dialog box appears Under Temporary Internet Files select the Cookie check box If the URL of the GX GP you use has been added to favorites clear the Preserve favorites website data check box and click Delete SOF Example with Internet Explorer 10 and 11 Click the Tools button and select Internet Options to open the Internet Options screen On the General tab under Browsing History click the Delete button The Delete Browsing History dialog box appears Under Temporary Internet Files select the Cookies and website data check box If the URL of the GX GP you use has been added to favorites clear the Preserve favorites website data check box and click Delete ON 6 2 Clearing the Java Runtime cache Contact Oracle for details Example with Java Runtime 1 7 0_xx version 7 update xx xx is 51 or later On the Start menu click Control Panel to open the Windows control panel Double click Java to open the Java control panel On the General tab under Temporary Internet Files click the Settings button to open the Temporary Files dialog box Click the Delete Files button In the confirmation dialog box select the Cached Applications and applets and Traces and log files check boxes a
2. Pl eee AD calibration EY Encryption Certificate Basic Information g GM10 5P705687 00 00 64 92 e5 33 Model GM10 2 Ay Update RS 422 485 Mathematical function with report function Comm channel function EtherNet IP communication WT communication Log scale Bluetooth Option Instruments tag Instruments tag No 00 Channel Information AI 10Ch DI 0Ch DO 0Ch Math 100Ch Communication 500Ch BD address AC 3F A4 1C 00 AB System reconfiguration A Recognized Module Reconfiguration El Update connected module Display module Figure7 System reconfiguration screen For details on system reconfiguration see section 2 24 2 Reconfiguring the GM in the SMARTDAC Data Acquisition System GM User s Manual IM04L55B01 01EN 9l GM10 Firmware Upgrade Procedure 9 Loading main unit settings Load the settings saved in step 4 9 1 9 2 9 3 9 4 9 5 Insert the SD memory card prepared in 4 into the SD memory card slot see figure 1 Using the contents selection tool click Data gt Save Load gt File List to open the save load screen see figure 8 In the save load screen under Folder select the settings folder you created in step 4 3 In the save load screen click Load all settings In the Load All Settings dialog box click OK Loading of settings begins Some settings may not be able to be loaded Check the settings after loadin
3. D memory card into the SD memory card slot see figure 1 4 3 Using the contents selection tool click Data gt Save Load gt File List to open the save load screen see figure 4 4 4 In the save load screen in the Folder box select the folder you created for saving settings 4 5 In the save load screen click Save all settings 4 6 In the Save All Settings dialog box click OK The settings are saved E SMARTDAC Web 10 0 123 113 SS sMARTDAC Web Service Cc E B EB E Recording Computing Alarm Trend Overview i341 E SYSTEM Save all settings File Name File type All available files B e Reload Save all datas Load all settings Figure 4 Save load screen 2 For details on saving settings see section 2 23 4 Saving Setting Parameters Report Templates and Trusted Certificates in the SMARTDAC Data Acquisition System GM User s Manual IM04L55B01 01EN 6l GM10 Firmware Upgrade Procedure 5 Upgrading the main unit Upgrade the GM10 main unit firmware according to the following procedure 5 1 5 2 5 3 5 4 5 5 5 6 Confirm that recording is in progress that the REC status LED is lit Turn OFF the power Insert the SD memory card prepared in 2 into the SD memory card slot see figure 1 Do not remove the SD memory card until the upgrade is complete Hold down the START key while turning ON the pow
4. GM10 Firmware Upgrade Procedure GM10 Firmware Upgrade Procedure This document describes the procedure for upgrading the GM10 firmware Please read this document before proceeding with the upgrade Applicable Products GM10 standard models only Excludes special specifications with suffixes of S1 999 or Z Note that in factory maintenance is required for those models Versions after Upgrade GM10 R2 02 06 Web Application R2 02 01 Items to Prepare m GMi0 m GMSO0PS GM90MB m SD memory card The SD memory card must be formatted using the SD card formatter distributed by the SD Association Other formats are not supported by the firmware upgrade m PC Ethernet cable and hub m SMARTDAC Data Acquisition System GM User s Manual IM04L55B01 01EN Notes Note 1 This document applies to the free GM10 firmware upgrade Note 2 When upgrading the firmware you must ensure that you also have the latest versions of all related software Note 3 If in factory maintenance or repair is ever required be sure to inform the factory that the unit has been upgraded Note 4 This upgrade restores various settings to their factory defaults It is recommended to save your current settings to the SD memory card in order to easily restore them after the upgrade Note 5 Data recorded on the GM10 main unit will be deleted when applying this upgrade Please save your data to the SD memory card prior to downloadi
5. ed in step 2 into the SD memory card slot see figure 1 3 2 Check whether recording is in progress that the REC status LED is lit If recording is in progress stop recording by holding down the STOP key for at least 3 seconds 3 3 Using the contents selection tool click Data gt Save Load gt File List to open the save load screen see figure 3 3 4 On the save load screen click Save all data 3 5 In the Save All Data dialog box click Save to SD Card The recorded data is saved SMARTDAC Web 10 0 123 113 hy S ee BS SMARTDAC Web Service perati Option 2015 01 16 16 06 59 E icp Ss v m m m a EA B Recording Computing Alam Trend Overview Alarm summary Print Config Window me iii 132 Folder J SD Bz 5 SYSTEM Folder 2015 01 13 12 57 16 Save all data File Name File type All available files a Save all settings Load al settings a Raima F Figure 3 Save load screen 1 For details on saving recorded data see section 2 23 6 Saving All the Data in the Internal Memory in the SMARTDAC Data Acquisition System GM User s Manual IM04L55B01 01EN 5l GM10 Firmware Upgrade Procedure 4 Saving main unit settings Use the web application to save settings recorded on the main unit according to the following procedure 4 1 Create a settings folder on the SD memory card you prepared in step 2 4 2 Insert the S
6. er When the 7 segment LED shows the in process display see figure 5 release the START key Figure 5 In process display When the 7 segment LED displays bC turn OFF the power With the SD memory card still inserted turn ON the power When the 7 segment LED shows the start up display see figure 6 the upgrade begins The upgrade can take several minutes Do not turn OFF the unit while the upgrade is in progress When the 7 segment LED displays 00 the upgrade is complete Figure 6 Start up display If the 7 segment LED displays bx where x is a number the upgrade failed Following step 2 save the upgrade data again to the SD memory card and then repeat step 5 During this process be sure not to delete the recording and settings data saved in steps 3 and 4 71 GM10 Firmware Upgrade Procedure 6 Deleting temporary Internet files After performing the upgrade if you used the web application you must clear the web browser and Java Runtime cache by following the procedure below If the cache is not cleared before proceeding the web browser s pre and post upgrade statuses will be out of synch resulting in possible malfunction Note that when the cache is cleared it may take a few seconds to load pages when you visit them for the first time but on and after the second time they will be displayed as quickly as before 6 1 Clearing the web browser s cache temporary Internet files Contact Microsoft for details
7. g and re enter settings if necessary before use i ca SMARTDAC Web 10 0 123 113 SS SMARTDAC Web Service Select a folder Operation E amp amp Folder SD 2015 01 13 12 57 16 Loading of all settings File Name E Reload gt dovnload Savealldatas Save all settings File type All available files Figure 8 Save Load screen 3 10 Upgrading the software If upgrading to the latest main unit firmware please also use the latest version of the related software below Visit the download page on our website for the latest releases of each program Related Software SMARTDAC STANDARD Universal viewer SMARTDAC STANDARD hardware settings SMARTDAC Report template builder SMARTDAC Excel report simulator Download Site http www smartdacplus com software en 10 GM10 Firmware Upgrade Procedure Yokogawa Electric Corporation ns cs jp yokogawa com www yokogawa com ns Issued in June 2015 copyright Yokogawa Electric Corporation 11
8. nd click OK 7 Checking the version Confirm whether the upgrade was successful by checking the main unit version number according to step 1 Because the upgrade restores all settings to their factory defaults you must re enter the IP address If you do not have the latest versions return to step 5 and repeat the upgrade 8 GM10 Firmware Upgrade Procedure 8 Main unit reconfiguration You can use the web application to reconfigure the main unit according to the following procedure 8 1 While recording is stopped confirm that the REC status LED is not lit 8 2 Using the contents selection tool click Calib gt Reconfiguration to display the system reconfiguration screen see figure 7 8 3 Inthe system reconfiguration screen click Reconfiguration 8 4 Inthe Reconfiguration dialog box click Execute The system is reconfigured During reconfiguration the System reconfiguring dialog box appears When complete the M8201 System configuration changed successfully dialog box appears Click OK The W8108 Since the system configuration changed information will be updated dialog box appears Click OK and confirm that installed modules are shown under Recognized Module SMARTDAC Web 10 0 123 113 Py me BS _SMARTDAC Web Service Operation Option 2015 01 16 16 09 35 E 5 E p 100 GS E BE B 5 Recording Computing Alarm Trend Overview Alarm summary Print Config Window Data Config Catib
9. ng 11 GM10 Firmware Upgrade Procedure Upgrade Procedure 7 segment LEDx2 7 segment LED Status display START Key STOP key USER1 and USER2 keys Higher Lower digit USB port me SD card slot Status display SD card slot with the cover open RS 422 485 SD card Serial port C3 option Ethernet port Figure 1 GM10 user interface hardware 2l GM10 Firmware Upgrade Procedure 1 Checking the main unit version Before starting the upgrade use the web application to check the main unit version number according to the following procedure 1 1 Using the contents selection tool click Data gt System information to display the system information screen see figure 2 1 2 On the system information screen under Basic Information check the Main Program and Web Program items If the version matches the post upgrade version you do not need to perform the upgrade SMARTDAC Web 10 0 123 113 M o wee BS SMARTDAC Web Service Cnet O a 2015 01 16 15 51 27 E eE Er 3 oom Li H B Recording Computing Alarm Trend Overview Alarm summary Print Config Window eee 121 i Basic Information Product Name GM10 eae Ea tle Main unit version MAC Address 00 00 64 92 e5 33 Firmware Version _ R2 02 01 p Vain Program R gt 02 Leb Procram R202 Model GM10 2 Option RS 422 485 Mathematical function with report function Comm channel functi
10. on EtherNeT We b a p p licatio n communication Log scale Bluetooth Instruments tag Instruments tag No 00 Channel Information AI 10Ch DI 0Ch DO 0Ch Math 100Ch Communication 500Ch BD address AC 3F A4 1C 00 AB Recognized Module Update connected module Figure 2 System information screen Preparation is required to use the web application For details see section 2 1 Preparing to Use the Web Application in the SMARTDAC Data Acquisition System GM User s Manual IMO4L55B01 01EN 3 GM10 Firmware Upgrade Procedure Preparing the SD memory card for the upgrade 2 1 Download the upgrade file from our website and save it on your PC 2 2 Double click the file and unzip it to a folder of your choice 2 3 Save the unzipped files see table 1 in the root directory of the SD memory card Before saving confirm that no other files used for upgrading are saved on the SD memory card Delete any such files before proceeding 2 4 Check whether the file and folder names in Table 1 are present Table 1 Firmware used for upgrades Files Folder Name File ndacSV_main rom File ndacSV_2_main rom File ndacSV_boot rom Folder SYSTEM 4 GM10 Firmware Upgrade Procedure 3 Saving data recorded on the main unit Use the web application to save data recorded on the main unit according to the following procedure 3 1 Insert the SD memory card prepar