Home
KX-TD500 Programming Guide
Contents
1. Program Default 17 Operator Call 0 18 Local CO Line Access ARS 9 19 Trunk Group Access 8 20 Speed Dialing System k 21 Speed Dialing Station 3 22 Speed Dialing Station Programming 30 23 Doorphone Call 31 24 External Paging 32 25 External Paging Answer TAFAS Answer 42 26 Station Paging 33 27 Station Paging Answer 43 28 CO Call Pickup 4 29 Group Call Pickup 40 30 Directed Call Pickup 41 31 Hold 50 32 Hold Retrieve Station 51 33 Hold Retrieve Trunk 53 34 Redial 35 Call Park Call Park Retrieve 52 36 Account Code 49 37 Door Open 55 38 External Feature Access 6 39 Station Program Clear 790 40 Message Waiting Set Cancel Call Back 70 41 OGM Playback Record 36 42 Call FWD Do Not Disturb Set Cancel 710 43 Dial Call Pickup Deny Set Cancel 720 44 Data Line Security Set Cancel 730 45 Call Waiting Set Cancel 731 46 Executive Busy Override Deny Set Cancel 733 47 Pickup Dialing Program Set Cancel 74 Programming Guide 363 Default Values Program Default 48 Absent Message Set Cancel 750 49 Timed Reminder Confirm Set Cancel 761 50 Station Lock Set Cancel 762 51 Night Mode Set Cancel 78 52 Parallel Telephone Mode 39 53 External BGM On Off 35 54 Live Call Screening 799 55 Call Log Incoming
2. Program Default PBX Access Code Blank Numbering Plan ID Outgoing Public Default Numbering Plan ID Outgoing Private Private Numbering Plan ID Incoming Public Default Numbering Plan ID Incoming Private Private PBX Dial Tone Disable PBX Ringback Tone Disable Type of Number Outgoing Public Default Type of Number Outgoing Private Default Type of Number Incoming Public Default Type of Number Incoming Private Default Cyclic Signal Detection Check Continuous Signal Detection No check Silence Detection Check 3 2 2 Trunk Group 2 2 Program Default ISDN Progress Tone Mode Automatic IRNA for TIE Line Disable 3 3 Extension Group Program Default Group No 1 Copy FDN Blank DN Refer Tenant No 1 Overflow Setting Destination Day Night Blank Overflow Setting Timer None Group Type Group No 126 VM Group No 127 AA Group No 128 Operator Others None Programming Guide 371 Default Values Program Default FWD DND Mode Enable Extension Call Hunting Enable Calls to Empty Group Disable UCD Setting Time Table No None UCD Setting FWD No Answer Disable UCD Setting Auto LOGOUT Mode Disable UCD Setting Supervisor Extension Blank UCD Setting LOGIN Monitor Disable UCD Setting UCD Call Waiting Enable Operator Setting Call Priority CO Call 1
3. Program Default Password System Programming Protection 1234 Level 1 Password System Programming Protection 1234 Level 2 Password System Programming Protection 1234 Level 3 Password System Programming Protection 1234 Level 4 Password User Programming PT 1234 Password Walking COS 1234 Serial Interface Port PROG Port 1 Serial Interface Port PROG Parity Display only Serial Interface Port PROG NL Code CR LF Serial Interface Port PROG Word Length Display only Serial Interface Port PROG Stop Bit Display only Serial Interface Port PROG Baud Rate 9600 bps Serial Interface Port SMDR Port 2 Serial Interface Port SMDR Parity None Serial Interface Port SMDR NL Code CR LF Serial Interface Port SMDR Word Length 8 bits Serial Interface Port SMDR Stop Bit 1 bit Serial Interface Port SMDR Baud Rate 9600 bps Remote FDN 1499 DN Refer Remote Connect Information Dial Number Blank Remote Connect Information Comment Blank 10 7 System Time Program Default System Time Year 00 386 Programming Guide Default Values Program Default Month Jan Day 01 Day of the week Sat Hour 12 Minute 00 AM PM AM Summer Time Daylight saving Time Setting Setting Disable Start Month Please refer to Default values of summer time End Mo
4. Program Default First Dial Timer 1 0s Break 60 Flash Time 608 ms Pulse Feedback Tone Yes Caller ID Inter digit Pause 830 ms Pulse Break Time Adjustment 0 ms Bell Detection Time 144 ms DTMF Inter digit Pause Time 112 ms Bell Disappearance Timer 5s Gain Adjustment 0 dB 1 2 6 Card Properties ELCOT Caller ID Program Default Caller ID Detection Check Detection Start Time 240 ms Carrier Detection Disable Detection Time 2000 ms Header Examination Enable LPR Version Display only 1 2 7 Card Properties T1 Program Default Line Coding B8ZS Frame Sequence ESF ESF Frame Option C A D B First Dial Timer CO 1 0s First Dial Timer DID TIE 64 ms Break 60 Programming Guide 355 Default Values Program Default Pulse Feedback Tone Yes Signaling Bit Monitor Port No Disable Signaling Bit Monitor Mode Mode 3 Software Information Display only Inter digit Pause 830 ms Flash Detection No Flash Detection Timer 208 1016 ms Answer Decision Timer 32 ms Break Detection 16 96 ms Transmission of RAI No 1 2 8 Card Properties BRI Program Default Network Type Display only DTMF Signal Duration 80 ms DTMF Signal Inter digit Pause 112 ms Status Message Enable Status Receive Disconnect Line Mode L1 Mode Display only Line Mode L2 Mode Display only
5. 7 Parameter T01 Default 60s Value Range 0 300 s Description Function Trunk port Specifies the maximum time allowed to the system after receiving the notification of incoming call from ISDN before replying to it Reference None Programming Guide 37 Configuration 38 Parameter T02 Default 35s Value Range 0 60 s Description Function Trunk port Specifies the maximum time allowed to the system after receiving the notification of call disconnection from ISDN before replying to it Reference None Parameter T03 Default 10s Value Range 0 60 s Description Function Trunk port Specifies the maximum time that the system waits after sending the request of call disconnection to ISDN before receiving the reply to it Reference None Parameter T04 Default 10s Value Range 0 60 s Description Function Trunk port Specifies the time to delay the announcement of call disconnection This setting is used when an announcement is given to the system from ISDN before disconnecting the call Reference None Parameter T05 Default 60s Value Range 0 300 s Description Function Extension port Specifies the maximum time allowed to the system after receiving the notification of incoming call from ISDN before replying to it Reference None Programming Guide Configuration Parameter T06 Default 35s Value Range
6. lt gt 7 amp Description Function Specifies the name for each speed dial code Notes e The stored name is shown on a large display PT such as KX T7235 KX T7436 when dialing System Speed Dialing number e Both Name and Number should be stored in pairs for each System Speed Dialing No Otherwise Name is not shown on a large display PT Reference e 4 5 8 KX T7235 Display Features Call Directory U M e 4 5 11 KX T7431 KX T7433 KX T7436 Display Features Call Directory U M Programming Guide Features Parameter Number Default Blank Value Range Up to 24 digits consisting of 0 9 x P S or F Description Function Specifies the telephone number for each speed dial code Note e P Pause S Secret Dialing F Hook Flash Reference None Programming Guide 253 Features 5 3 Phantom Extension Used to register up to 448 Phantom Extension numbers 5 2 Phantom Extensior fooi o48 ea 5 2 Phantom Extension ETL i Parameter Entry No Default 001 048 Value Range 001 448 in 48 codes increments Description Function Specifies the entry number of phantom extension number which you are going to program Reference e 1 3 System Features F G 254 Phantom Extension Programming Guide Features Parameter FDN Default Blank Value Range 3 4 digits consisting of 0 9
7. Parameter 25 Pressing DSS key operation in CO talking Default Hold Value Range 1 Disconnect 2 Hold Description Function If set to Hold the PT user engaged in a CO call can transfer the current call to another extension simply by pressing the DSS button associated with the destination extension Reference e 1 11 Transferring Features F G One Touch Transfer Parameter 26 Pressing CO DN Answer key operation in talking Default Disconnect Value Range 1 Disconnect 2 Hold Description Function If set to Hold the PT user engaged in a call can with a single operation press a CO DN Answer key hold the current call and then either get another line or answer another call Reference e 1 10 Holding Features F G Automatic Hold For Hold Parameter 27 Message Waiting lamp pattern Default 11 Value Range 01 12 Description Function Specifies a light pattern of the Message Lamp of an SLT Note e Message Waiting lamp pattern list is provided on Page 134 and Page 135 Reference e 1 17 Display Features F G Programming Guide Message Waiting e 4 3 46 Message Waiting U M 137 System 138 Parameter 28 Trunk hunting mode Default Forced Value Range 1 Forced 2 Loop Detection Description Function Specifies the trunk hunting mode 1 Forced The system seizes a trunk line whether or not loop current is detected from the local CO 2 Loop Detection The system seizes
8. Parameter Output Type Default Type A Value Range 1 Type A 2 Type B Description Function Specifies the output type of SMDR Printout For further information please refer to Station Message Detail Recording SMDR of Section 1 3 System Features in the Features Guide You can also get information on Output Type by clicking Help on this screen Reference e 1 3 System Features F G Station Message Detail Recording SMDR Parameter Print out Error Information Default Disable Value Range 1 Disable 2 Enable Description Function Specifies whether or not the Error Information will be printed out by SMDR Reference 5 2 3 Troubleshooting via Error Log Records I M Parameter Format Page Length Default 24 lines Value Range 4 99 lines Description Function Specifies the number of lines per page Used to match the SMDR output to the paper size being used in the printer Reference None Programming Guide 315 Maintenance 316 Parameter Format Skip Perforation Default 0 Value Range 0 95 lines Description Function Determines the number of lines to be skipped at the end of every page The number of lines to skip is simply the number specified in this parameter The number of lines printed is the difference between the Page Length number and the Skip Perforation number Reference None Parameter Duration Log Outgoing Calls Default All Value Range 1 None 2 All 3 Toll Only
9. 376 Programming Guide Default Values 4 4 1 Flexible DSS Key Assignment Program Default Key Type Not Stored 4 4 2 Flexible PF Key Assignment for DSS Console Program Default Key Type Not Stored 4 5 Doorphone Program Default Card No Port No 1 Tenant No 1 Destination Day Night Blank 4 6 External Paging Program Default Pager No Display only Tenant No 1 FDN Blank BGM No check BGM Source MUS1 DN Refer 4 7 ISDN Extension Line Program Default Card No Port No Group No Display only Name Blank Programming Guide 377 Default Values Program Default Tone Enable ISDN Bearer Mode Automatic Numbering Plan ID Default Type of Number Default CLIP Number Public Blank CLIP Number Private Blank COS No Primary 1 COS No Secondary 1 5 Features 5 1 Features 5 2 System Speed Dialing Program Default Tenant No 1 Entry No 000 019 Max Entry Display only Current Registration Display only Name Blank Number Blank 5 3 Phantom Extension Program Default Entry No 001 048 FDN Blank DN Refer 5 4 Emergency Dial Code Program Default Dial 1 911 Others Blank 378 Programming Guide Default Values 5 5 Quick Dial
10. Parameter TIE Line Sending TIE Caller ID Default No Value Range 1 No 2 Yes Description Function Specifies whether to send or not the TIE Caller ID to the other end Reference 3 1 TIE Line Features F G TIE Line Service Parameter Caller ID Default Disable Value Range 1 Disable 2 Enable Description Function Specifies the waiting timer to receive the Caller ID that is sent from the CO with an incoming call When you select Disable the system does not wait so the ringing starts immediately i e the system does not wait for the Caller ID which may take a few seconds Reference e 1 5 Attended Features F G Caller ID Service on T1 Line Programming Guide Line 4 3 Extension Line 4 3 1 Extension Line 1 2 Used to assign parameters for extension lines 4 2 Extension Line 1 2 fosesic zjeonno l I Ringing Line evo f A e OOo ok any canei te Programming Guide 211 Line Extension Line Copy Used to copy a part of or all settings of a certain Extension Line to all other Extension Lines at atime You can also specify one or several Extension Lines as the copy destination Extension Line Copy CopyfromDN 1001 r Copy Item r Destination Extension Line DN Card Port Name 103 ESLC 1003 103 ESLC 03 1004 103 ESLC 04 1005 103 ESLC 05 1006 103 ESLC 06 1007 103 ESLC 07 1008 103 ESLC 08 1009 103 ESLC 09 1010 103 ESLC 10 1011 103 ESLC
11. 10 6 System Parameters Used to assign various system parameters 10 4 System Parameters m Password 4 7 Digits System Programming User Programming PT Walking COS Protection Level 1 Protection Level 2 Protection Level 3 Protection Level 4 1234 1234 1234 1234 1234 1234 PERT r Serial Interface Port PROG SMDR Parity ore Nore NL Code crR F oR LF gt Word Length 8 hits jews gt Stop Bit fm Aft F Baud Rate 9600 bps x 9600 bps x gt Remote FDN Max 4 Digits 1499 DN Refer Comment Remote Connect Information Dial Number 10 4 System Parameters x OK Apply Cancel Help Passwords for System Programming by PC Required to perform the System Programming and Maintenance in the interactive mode using the Maintenance Console software from a PC Personal Computer There are four passwords for System Programming by PC To prevent unauthorized access to the interactive System Programming and Maintenance mode the KX TD500 System provides the following four passwords with a different security level respectively Password System Programming Protection Level 1 Allows the administrator to access all System Programming and Maintenance features without restrictions Passwords are originally programmed at the factory but can be changed by System Programming available only when gaining access to the
12. Parameter Copy Default Value Range Description Function You can enter into Extension Line Copy screen by clicking this button Reference Parameter Name Default Blank Value Range Up to 10 characters consisting of 0 9 A Z a z or the following marks lt gt 7 amp Description Function Specifies the name for the extension line Note e This is shown on the called party s display PT so that he knows who is calling Reference e 1 17 Display Features F G Display Call Information Parameter Message Lamp Default No Value Range 1 Yes 2 No Description Function Assigns whether an SLT with MESSAGE lamp can receive the message waiting indication or not Assignable when an SLT with Message lamp is interfaced by an SLC M or ESLC card Reference e 1 17 Display Features F G Message Waiting Programming Guide Line Parameter Mailbox No Default Same as the extension number Value Range Up to 16 digits consisting of 0 9 or P Pause Description Function Specifies the mailbox number which is usually the same as the extension number Note e This mailbox number is sent to the VPS as Follow on ID when Inband Integration is activated and when Programmed number is specified in Extension s mailbox number setting in Section 5 10 VPS Integration Reference None Parameter CO Key Default Value Range Description Function Yo
13. 1 2 Slot Assignment Card Properties Guide Card Properties screen lists and lets you customize the operating characteristics associated with a certain optional card The following optional cards have Card Properties screens Extension Cards HLC SLC OPX SLC M DHLC ESLC DLC Trunk Cards LCOT GCOT ELCOT T1 BRI PRI23 Resource Cards DISA ERMT The contents of Card Properties screens vary from one type of optional card to another but similar optional cards have similar Card Properties screens Note e You can get information on Card Properties parameters by opening Help menu on the Menu bar The following explanation is assumed that five DHLC cards are assigned to Slot No 1 to No 5 respectively by Slot Assignment Editing Card Properties Parameters You can edit Card Properties parameters according to your needs 1 Point to the Card Type button of the target card and click e Slot No 101 screen is displayed Slot No 101 Card Type X Properties Properties Copy Apply Cancel Help Programming Guide 7 Configuration 2 Point to Properties and click e Card Properties screen is displayed Card Properties 101 DHLO 3 After editing the parameters click OK e Card Properties screen is closed and Writing is displayed while the data changes are being saved Copy Function When multiple numbers of the same type optional cards a
14. Parameter Manual Initialization Command 1 5 Default All Blank Value Range Up to 80 characters consisting of 0 9 A Z a z or the following marks 3 lt gt amp Description Function Specifies Modem Manual Initialization Command Reference e 1 3 System Features F G External Modem Control e 4 3 36 External Modem Control U M Programming Guide 311 Maintenance 312 Parameter Automatic Initialization Command Default AT amp FOQOEOV 1S0 1X0 amp D0 Value Range Up to 80 characters consisting of 0 9 A Z a z or the following marks lt gt 7 amp Description Function Specifies Modem Automatic Initialization Command Note e A hardware flow control cannot be done by the communication port of KX TD500 Therefore the hardware flow control of your modem must be disabled to communicate correctly It depends on the type of the modem you use In most cases hardware flow control can be disabled by sending the amp K0 command from the PBX to the external modem Please refer to the manual of the external modem you use for further information It is recommended to add this command to Automatic Initialization Command the command to initialize the modem automatically every time an external modem is plugged into the RS 232C Port 1 Reference e 1 3 System Features F G External Modem Control 4 3 36 External Modem Control U M Programming Guide Ma
15. 0k ay cancel Helm Parameter Dial Default All Blank Value Range Up to 24 digits consisting of 0 9 x F P S or hyphen Description Function Specifies the phone number for Quick Dialing Note e Any extension user can use Quick Dialing number simply by dialing the feature number for Quick Dial 1 8 Reference e 1 7 Dialing Features F G Quick Dialing e 4 3 65 Quick Dialing U M 257 Programming Guide Features 5 6 Account Code 258 Used to program a list of up to 1000 account codes which are used to identify incoming and outgoing CO calls for accounting and billing purposes 0001 0020 Parameter Tenant No Default 1 Value Range 1 8 Description Function Specifies the tenant to which a list of Account Codes is assigned Required when Tenant Service is employed Reference e 1 3 System Features F G Tenant Service 2 2 Tenant P G Parameter Entry No Default 0001 0020 Value Range 0001 1000 in 20 codes increments Description Function Specifies the entry number of the Account code which you are going to program Reference None Programming Guide Features Parameter Code Default Blank Value Range Up to 10 digits consisting of 0 9 Description Function Specifies the account codes Reference e 1 3 System Features F G Account Code Entry e
16. Intercept Routing 155 Group Parameter Pause Time before Flash Signal Default 512 ms Value Range 1 None 2 512 ms 3 1024 ms 4 1536 ms 5 2048 ms Description Function Specifies the pausing time required before sending the Flash Signal Reference None Parameter Max Dial No after EFA Signal Default 0 Value Range 0 32 Description Function Specifies the maximum dialing digits allowed after sending EFA External Feature Access signal Note e Ifset to 0 the dialing digits can be sent without limit Reference e 1 12 Conversation Features F G External Feature Access e 4 3 35 External Feature Access U M 156 Programming Guide Group Parameter Line Hunting Order Default Reverse Value Range 1 Normal 2 Reverse 3 Sequential Description Function Specifies the hunting sequence of idle lines on a trunk group basis 1 Normal The system connects the user to an idle trunk line with the lowest physical number 2 Reverse The system connects the user to an idle trunk line with the highest physical number 3 Sequential To avoid repeated use of the same trunk line rotation is performed in numerical order from the lowest to the highest trunk port physical number Busy lines are skipped of course Reference 2 8 System Option P G Trunk hunting mode Parameter Tenant No Default 1 Value Range 1 8 Description Function Specifies the tenant 1 8 to which the tru
17. Trunk Group Setting on Class Parameter Trunk Group No 01 48 Day Night Default All Check Value Range 1 No check Restricted 2 Check Not restricted Description Function Specifies the trunk group 01 48 which the extension user can use for making an outside call in Day Night mode respectively on a COS basis Reference e 1 3 System Features F G Trunk Group 3 2 Trunk Group P G Programming Guide System 2 4 3 Class of Service COS 2 2 Used to assign the Class of Service COS parameters pisane H 23cassorsemce22 Bl ae Cancel Hee Parameter Secret Busy Override Default Disable Value Range 1 Enable 2 Disable Description Function Enables or disables Secret Busy Override feature Reference e 1 6 Originating Features F G Secret Busy Override e 4 3 69 Secret Busy Override U M Parameter Transferring CO dial tone exempted from TRS Default Enable Value Range 1 Enable 2 Disable Description Function Allows you to transfer a CO dial tone to another extension so that it can make an outgoing call without TRS Reference e 1 6 Originating Features F G Programming Guide Toll Restriction 111 System Parameter Transfer to TIE Default Value Range Description Function Reference Disable 1 Enable 2 Disable Enables or disables Call Transfer to
18. e The message Import is displayed and copying the System Speed Dial data begins e When copying is finished 5 12 Caller ID Registration screen is displayed again Parameter Tenant No Default 1 Value Range 1 8 Description Function Specifies the tenant to which the Caller ID codes are assigned Required when Tenant Service is employed Reference e 1 3 System Features F G Tenant Service 2 2 Tenant P G Parameter Entry No Default 0001 0010 Value Range 0001 1000 in 10 codes increments Description Function Specifies the entry number of Caller ID codes which you are going to program Reference None Parameter Import from Sys Speed Dial Default Value Range Description Function Please refer to Import from System Speed Dial in this section Reference None Programming Guide 277 Features 278 Parameter Name Default Blank Value Range Up to 16 characters consisting of 0 9 A Z a z or the following marks lt gt 7 amp Description Function Specifies the name to a Caller ID code Note e With Caller ID Service the calling party is displayed either by its ID Code or name If the name display is required use this program to give a name to a Caller ID code Reference e 4 5 4 Call Log Incoming KX T7436 KX T7433 KX T7235 KX T7230 only U M Parameter Number Default Blank Value Range Up to 24 digits consisting of 0 9 or Descripti
19. Parameter CLIP Number Public Default Value Range Description Function Reference Blank Up to 16 digits consisting of 0 9 X or Specifies a CLIP number used for the incoming outgoing calls via Public Switched Telephone Network to each extension Notes e When an extension user makes an outside call using an ISDN BRI line the number stored in DN lt Section 1 2 9 Card Properties BRI SPID DN in the Programming Guide gt is displayed on the telephone of the other party as the CLIP number e Specify the registered Central Office calling number for correct operation of CLIP e 2 2 ISDN Originating Features F G Calling Line Identification Presentation CLIP e 4 3 19 Calling Line Identification Presentation CLIP U M Parameter CLIP Number Private Default Value Range Description Function Reference 222 Blank Up to 16 digits consisting of 0 9 or Specifies a CLIP number used for the incoming outgoing calls via Private Network to each extension Notes e When an extension user makes an outside call using an ISDN BRI line the number stored in DN lt Section 1 2 9 Card Properties BRI SPID DN in the Programming Guide gt is displayed on the telephone of the other party as the CLIP number e Specify the registered Central Office calling number for correct operation of CLIP e 2 2 ISDN Originating Features F G Calling Line Identificatio
20. Parameter Timed Reminder Arrive Wait Time Default 60 s Value Range 20 240 s Description Function Specifies the interval time between each Timed Reminder Remote Timed Reminder Wake Up Call attempt Reference e 1 8 Ringing Features F G Timed Reminder Wake Up Call Timed Reminder Remote Wake Up Call e 4 3 74 Timed Reminder Wake Up Call U M e 4 4 11 Timed Reminder Remote Wake Up Call U M Parameter Intercept Time Default Day 12 rings Night Lunch Break 0 ring Value Range Day 1 48 rings Night Lunch Break 0 48 rings Description Function Specifies the number of rings the system is to wait before activating IRNA Intercept Routing No Answer feature If an incoming CO call directed to a single extension is not answered within this timer IRNA redirects the call to another pre programmed destination Notes e Call Forwarding No Answer Time will override this timer if an extension has enabled Call Forwarding No Answer e If O is specified in Night Lunch Break mode Intercept Time in Day mode works Reference e 1 11 Transferring Features F G Intercept Routing Programming Guide System 2 6 Local Hunt Sequence Specifies the trunk group hunt sequence to be used when an extension user attempts to make an outside call by dialing the feature number for Local CO Line Access ARS or by pressing a Loop CO key 2 5 Local Hunt Sequence Hunting Trunk Order Group No 01 09 jNone 17 None 25 N
21. 6 Toll Restriction 7 ARS 8 Private Network KIRA AIA SIAII S 9 DID Dial 10 Maintenance KIARA A AIA AAAS V Allowed to access Programming Guide 323 Maintenance 324 Parameter Password System Programming Protection Level 1 Default 1234 Value Range 4 7 digits of alphanumeric characters Description Function Specifies the password required for entering the System Programming and Maintenance mode from a PC Personal Computer Reference e 3 5 Operational Mode I M e 4 Utility I M Parameter Password System Programming Protection Level 2 Default 1234 Value Range 4 7 digits of alphanumeric characters Description Function Specifies the password required for entering the System Programming and Maintenance mode from a PC Reference e 3 5 Operational Mode I M e 4 Utility I M Parameter Password System Programming Protection Level 3 Default 1234 Value Range 4 7 digits of alphanumeric characters Description Function Specifies the password required for entering the System Programming and Maintenance mode from a PC Reference e 3 5 Operational Mode I M e 4 Utility I M Parameter Password System Programming Protection Level 4 Default 1234 Value Range 4 7 digits of alphanumeric characters Description Function Specifies the password required for entering the System Programming and Maintenance mode from a PC Reference e 3 5 Operationa
22. System 96 Parameter 57 Timed Reminder Remote Default T Value Range 1 4 digits consisting of 0 9 or Description Function Specifies the feature number for setting canceling Timed Reminder Remote feature For Manager Operator only Reference e 4 4 11 Timed Reminder Remote Wake Up Call U M e 1 8 Ringing Features F G Timed Reminder Remote Wake Up Call Parameter 58 Login Logout Default 45 Value Range 1 4 digits consisting of 0 9 X or Description Function Specifies the feature number for Log in Log out to from the members of an Extension Group and Phantom Extensions Reference e 4 3 45 Log In Log Out U M Parameter 59 Automatic Callback Busy Cancel Default 46 Value Range 1 4 digits consisting of 0 9 or Description Function Specifies the feature number for canceling Automatic Callback Busy feature Reference e 4 3 6 Automatic Callback Busy Camp On U M Parameter 60 Walking COS Default 47 Value Range 1 4 digits consisting of 0 9 X or Description Function Specifies the feature number for setting canceling Walking COS feature Reference e 4 3 84 Walking COS U M Programming Guide System Parameter 61 MODEM Control Default 791 Value Range 1 4 digits consisting of 0 9 or Description Function Specifies the feature number for External Modem Control An external modem can be connected to RS 232C port 1 R
23. 15 Special dial tone after setting feature Enable 17 Destination Busy DISA Send busy tone 18 Destination Busy DID Send busy tone 19 Destination Busy TIE Send busy tone 20 Off hook Monitor Enable 2 8 3 System Option 3 Program Default 21 Ilegal Number DISA Send reorder tone 22 Illegal Number DID Send reorder tone 23 Illegal Number TIE Send reorder tone 24 Sending dial tone to TIE trunk Disable 25 Pressing DSS key operation in CO talking Hold 26 Pressing CO DN Answer key operation in Disconnect talking 27 Message Waiting lamp pattern 11 28 Trunk hunting mode Forced 29 Card CODEC Mu Law 368 Programming Guide Default Values Program Default 30 Net CODEC Mu Law 2 8 4 System Option 4 Program Default 31 Answering Call Waiting call by SLT hooking Disable 32 Whisper OHCA to extensions other than Disable T74XX 33 FWD DND lamp pattern FWD Flash DND On 34 ELCOT LCOT Busy out Loop Relay OFF 35 GCOT Busy out Loop Relay OFF RING OPEN 36 Tone Mode Type 1 37 Ring Mode Type 1 38 First Digit Time out Process Don t release the trunk 41 Fixed Feature Number Type 1 42 DPT Ringer OFF Enable 43 LCD Time Display Mode 12h 46 Date Display M D Y 47 Tone Type for Outgoing Calls Bu
24. 30 s BRD 0 s PRI23 CO Qsig Master PRI only Qsig Slave PRI only T310 0 s BRD 30 s PRI23 CO Qsig Master PRI only Qsig Slave PRI only T3D3 10 s BRD 30 s PRI23 CO Qsig Master PRI only Qsig Slave PRI 20s only T3D9 Extension T200 ls Extension T203 10s Extension T302 10 s BRD 15 s PRI23 Extension T303 5 s BRD 2 s PRI23 Extension T304 Os Extension T305 30 s BRD 4 s PRI23 Extension T306 30s Extension T310 10 s BRD 40 s PRI23 Extension T3D3 30s Extension T3D9 0 s BRI 20 s PRI23 1 2 12 Card Properties DISA Program Default CYCLIC Tone Detection Mode Standard Decision Count 4 times Tone ON Time Min 144 0 ms Tone ON Time Max 244 8 ms Tone OFF Time Min 144 0 ms Tone OFF Time Max 244 8 ms LPR Version Display only 358 Programming Guide Default Values 1 2 13 Card Properties ERMT Program Default Baud Rate Modem Speed 33600 bps 1 2 14 CPU Card Information Program Default Software Version Display only Area Code Display only 1 2 15 TSW Card Configuration Program Default Option Card Status Conference Expansion Card Display only Option Card Status Digital OHCA Card Display only System Clock Status Display only Clock Configuration Mode External Clock Configuration Maste
25. Default 15s Value Range 1 0 558 2 1 0s 3 1 5s 4 2 0s Description Function Specifies the length of time in seconds the system is to wait after Voice Mail port answers a call before sending DTMF signals such as a mailbox number Follow on ID to Voice Mail port Reference e 1 3 System Features F G Integration VPS Parameter Pause timing before sending DTMF signal RBT BT Default 15s Value Range 1 0 558 2 1 0s 3 1 558 4 2 0s Description Function Specifies the length of time in seconds the system is to wait before sending Integration Code with DTMF signals System Voice Mail Extension Status Reference e 1 3 System Features F G Integration VPS Parameter Turn off control of Message Waiting lamp Default System Value Range 1 System 2 Voice Mail Description Function Specifies whether the system or the Voice Mail port turns off the Message Waiting lamp after the extension user retrieved a message recorded in his mailbox Reference e 1 3 System Features F G Integration VPS e 1 17 Display Features F G Message Waiting Programming Guide Features Parameter Start AA service after FWD IRNA of CO call Default Do not start Value Range 1 Do not start 2 Start Description Function Specifies whether the system starts the AA Automated Attendant Service or not when a CO call is directed to Voice Mail port by Call Forwarding or Intercept Routing If Start is specified AA
26. Programming Guide 237 Line lt Key Type Assignment gt The following Key Type Assignment screen is displayed by clicking Key Type Display button including Not Stored for each PF Key on the above screen Flexible PF Key 1 Key Type Dial Warme Bip Not Stored a OK Cancel Help lt Additional Parameters Required by Key Type gt Depending on a Key Type additional parameters are required as follows Additional oer Key Type Parameters Description ONE TOUCH Dial Specifies the telephone number or feature access number up to 24 digits consisting of 0 9 X P S or F Note e P Pause S Secret Dialing F Hook Flash Name Specifies the name for One Touch Dialing up to 10 characters consisting of 0 9 A Z a z or the following marks 1 lt gt amp VTR DN Specifies the Directory Number of the Voice Mail extension 238 Programming Guide Line Parameter Key Type Default Value Range Description Function Reference Programming Guide Not Stored Please refer to Description Function Not Stored Key Type is not assigned ONE TOUCH One Touch Dialing button FWD DND Call Forwarding Do Not Disturb button SAVE Saved Number Redial button ACCOUNT Account Code entry button CONF Conference button VTR Voice Mail Transfer button ANSWER Answer button RELEASE Release button e 2 2 3 Flexible
27. Specifies the T1 PCM Pulse Code Modulation Line Coding type for each T1 card Reference e 1 3 System Features F G T1 Carrier Parameter Frame Sequence Default ESF Value Range 1 D4 2 ESF Description Function Reference Specifies the Frame Sequence type for each T1 card e 1 3 System Features F G T1 Carrier Programming Guide Configuration Parameter ESF Frame Option Default C A D B Value Range 1 C A D B 2 C 0 D 0 3 C 1 D 0 4 C 0 D 1 5 C 1 D 1 Description Function Defines the values of C bit and D bit Assignable only when Frame Sequence is set to ESF Reference 1 3 System Features F G T1 Carrier Parameter First Dial Timer CO Default 1 0s Value Range 0 5 8 0 s in 0 5 s increments Description Function On outgoing CO calls the system waits at least 1 0 second after seizing the CO line before sending the dialing digits to the Central Office by default This allows the Central Office enough time to accept the dialing digits correctly Specifies the appropriate value depending on the requirements of your local Central Office Reference e 1 3 System Features F G Programming Guide T1 Carrier 25 Configuration 26 Parameter First Dial Timer DID TIE Default 64 ms Value Range 32 8160 ms in 32 ms increments Description Function On outgoing DID TIE line calls the system waits at least 64 milliseconds after seizing the tr
28. T7130 APT with SP PHONE 1 Line Display 12 CO T7020 APT with SP PHONE 12 CO T7030 APT with SP PHONE 1 Line Display 12 CO T7050 APT with MONITOR 12 CO T7055 APT with MONITOR 3 CO T7320 APT with SP PHONE 12 CO T7335 APT with SP PHONE 1 Line Display 12 CO T7350 APT with MONITOR 12 CO T7220 DPT with SP PHONE 24 CO T7230 DPT with SP PHONE 2 Line Display 24 CO T7235 DPT with SP PHONE 6 Line Display 12 CO T7250 DPT with MONITOR 6 CO T7420 DPT with SP PHONE 12 CO T7425 DPT with SP PHONE 24 CO T7431 DPT with SP PHONE 1 Line Display 12 CO T7433 DPT with SP PHONE 3 Line Display 24 CO T7436 DPT with SP PHONE 6 Line Display 24 CO T7040 T7240 DSS Console 32 DSS 16 PF T7440 DSS Console 66 DSS T7441 DSS Console with ANSWER and RELEASE buttons 48 DSS Note Some features of a KX T7400 series PT do not function unless it is connected to a DLC or DHLC card whose LPR Version ROM Version is 1 or later e 1 3 System Features F G Mixed Station Capabilities Programming Guide Configuration Parameter DN Default 1001 Value Range 3 4 digits consisting of 0 9 Description Function Specifies the DN Directory Number extension number for the extension port Note e You must assign the paired extension for DN after selecting DSS for the attribute Reference 2 3 Numbering Plan P G Parameter Group No Default 1 Va
29. tafone Ff g None E 20 None E g None afine E 10 None 22 None F 11 None 23 None 12 None 24 None F 13 None f 14 None 15 None Ff 16 None Ff i7 None E 18 None f 19 None 20 None 2i None f 22 None Ff a3 None 24 None 10 3 Power Failure Transfer Parameter Trunk Card 1 24 Default None Value Range None XXX YYY XXX Card No 101 314 YYY Card Type Description Function Specifies the trunk card number and its type which will be used in case of Power Failure Transfer Reference e 1 4 Fault Recovery Diagnostics F G Power Failure Transfer e 2 9 1 Auxiliary Connection for Power Failure Transfer I M e 1 2 Slot Assignment P G Programming Guide Maintenance Parameter Extension Card 1 24 Default None Value Range None XXX YYY XXX Card No 101 314 YYY Card Type Description Function Specifies the extension card number and its type which will be used in case of Power Failure Transfer Notes e DPTs and some APTs cannot be used during a power failure e Auxiliary connections between the Trunk card and Extension card should be made as per System Programming so that conversation is maintained when power is restored or TSW is recovering Reference e 1 4 Fault Recovery Diagnostics F G Programming Guide Power Failure Transfer e 2 9 1 Auxiliary Connection for Power Failure Transfer I M 1 2 Slot Assignment P G 321 Maintenance
30. 1 Entry No 1 10 Maintenance 10 1 Maintenance 10 2 External Modem 1 2 Program Default Manual Initialization Command 1 5 All Blank Automatic Initialization Command AT amp FOQOEOV 1S0 1X0 amp D0 10 3 External Modem 2 2 Program Default Connection Message 1 5 Message 1 CONNECT Others Blank Disconnection Message 1 5 Message 1 NO CARRIER Others Blank 384 Programming Guide Default Values 10 4 SMDR 10 4 1 SMDR 1 2 Program Default SMDR Connection No Output Type Type A Print out Error Information Disable Format Page Length 24 lines Format Skip Perforation 0 Duration Log Outgoing Calls All Duration Log Incoming Calls On Print out Caller ID Information Number Print out DID Information Disable Print out Incoming Call Start RC and Incoming Disable Call Answer AN information Print out Timed Reminder Information Disable Print out Account Code Enable Last Entered Code Print out LOGIN LOGOUT Disable Time Display Mode 12h 10 4 2 SMDR 2 2 Program Default Print out supplementary digits ISDN only Disable 10 5 Power Failure Transfer Program Default Trunk Card 1 24 None Extension Card 1 24 None Programming Guide 385 Default Values 10 6 System Parameters
31. 1 8 BRI Port Assignment P G Parameter Name Default Blank Value Range Up to 10 characters consisting of 0 9 A Z a z or the following marks 3 lt gt 7 amp Description Function Specifies the name for the ISDN extension line Reference e 1 17 Display Features F G Display Call Information Parameter Tone Default Enable Value Range 1 Enable 2 Disable Description Function Specifies whether the system sends the call progress tone to the ISDN extension or not Reference None Programming Guide 245 Line 246 Parameter ISDN Bearer Mode Default Automatic Value Range 1 Automatic 2 Speech 3 3 1 KHz Audio Description Function Specifies the ISDN Bearer Mode on an ISDN extension basis Note e When Automatic Default is selected Bearer Mode is set automatically depending on the type of extension telephone as follows PT Speech SLT 3 1 KHz Audio ISDN extension depending on the bearer mode of the ISDN extension Reference e 2 1 ISDN Features F G Integrated Services Digital Network ISDN Parameter Numbering Plan ID Default Default Value Range 1 Default 2 Unknown 3 ISDN Telephony 4 National Standard 5 Private Description Function Specifies the Numbering Plan ID applied to the outgoing incoming CO calls via ISDN Reference None Parameter Type of Number Default Default Value Range 1 Default 2 Unknown 3 International 4 National 5
32. 11 1012 103 ESLC 12 1013 103 ESLC 13 1014 103 ESLC 14 1015 103 ESLC 15 1016 103 ESLC 16 IV CLIP Number 1017 111 ESLC 01 V CO Key 4n49 4144 Fale IV PF Key V JOG Dial Speed SelectAll MV ISDN Bearer Mode M Intercept Destination Execute Cancel Help W Call Forwarding No Answer Time I Initial Display Selection I Preferred Line V Data Line Mode i Call Waiting Tone Type IV Call Pickup Deny V Language V LCS Setting IV Station Lock Password lV Call Log Incoming IV Pickup Dialing Copying the Extension Line Parameters to Other Extension Lines 1 Edit the parameters of the copy source Extension Line and save it 2 Point to Copy on 4 2 Extension Line screen of the copy source and click e Extension Line Copy screen is displayed e The current Extension Line copy source number is shown as Copy from DN XXXX 3 Select the Extension Line parameters to copy in Copy Item field e Only parameters which are available to copy are shown in Copy Item field This depends on the attribute of the copy source Extension Line Items marked with are copied Select All in the Destination Extension Line field and click 4 Point to e All displayed Extension Line Nos will be highlighted e You can also specify one or several Extension Lines as the copy destination by clicking it them directly 5 Point to Execute and c
33. Click Execute The following DID MDN numbers are registered in Entry Nos 1 100 of DID MDN No automatically Programming Example Entry No 1 123456 00 Entry No 2 123456 01 Entry No 3 123456 02 Entry No 99 123456 98 Entry No 100 123456 99 Notes If more than 15 digits are entered in Base Number Dial field the following warning message will be displayed W9005 Base dial number must not exceed 15 digits Truncate it If you click OK the exceeded digits will be truncated automatically If the total digits of Base Number and Number of Digits are over 16 the following error message will be displayed E9010 Number of DID dial must be equal to or less than 16 digits Then the operation will be aborted If Beginning Entry No exceeds 991 the following error message will be displayed E9011 Beginning Entry No must be equal to or less than 991 Then the operation will be aborted The new entries will override the old ones if DID MDN numbers are already registered in the specified areas If the number of remaining Entry fields is less than the number specified by Number of Registrations setting for example Number of Registrations is 20 and Beginning Entry No is 991 10 of 1000 Entry fields are left only the first 10 DID MDN numbers are registered Parameter Base Number Dial Default Blank Value Range Up to 15 digits consisting of 0 9 Descri
34. Group DN External OGM Extension Phantom RMT Incoming Type Pager Group Group Extension Group Terminate Y Operator Vv Vv Y Y UCD Y Vv Y Y Ya v assignable When DIL 1 N is specified in Group Type programming of Incoming Group this feature does not work Incoming Group Copy Used to copy a part of or all settings of a certain Incoming Group to all other Incoming Groups at a time You can also specify one or several Incoming Groups as the copy destination Copying the Incoming Group Parameters to Other Incoming Groups 1 Edit the parameters of the copy source Incoming Group and save it 2 Point to on 3 4 Incoming Group screen of the copy source and click e Incoming Group Copy screen is displayed e The current Incoming Group copy source number is shown as Copy from Incoming Group 1 96 fa Calle to Ennpty Group E G Ea eee ameeeeeee E u U U U E 182 Programming Guide Group 3 Select the Incoming Group parameters to copy in Copy Item field e Only parameters which are available to copy are shown in Copy Item field This depends on the Group Type assignment of the copy source Incoming Group e Items marked with are copied 4 Point to Select All in the Destination Incoming Group field and click e All displayed Incoming Group Nos will be marked with v e You can also specify one or seve
35. Reference 4 3 9 Call Forwarding U M e 4 3 27 Do Not Disturb DND U M Programming Guide System Parameter 43 Dial Call Pickup Deny Set Cancel Default 720 Value Range 1 4 digits consisting of 0 9 or Description Function Specifies the feature number for setting canceling the Dial Call Pickup deny feature Reference e 4 3 14 Call Pickup Deny U M Parameter 44 Data Line Security Set Cancel Default 730 Value Range 1 4 digits consisting of 0 9 X or Description Function Specifies the feature number for setting canceling the Data Line Security feature Reference e 4 3 25 Data Line Security U M Parameter 45 Call Waiting Set Cancel Default 731 Value Range 1 4 digits consisting of 0 9 x or Description Function Specifies the feature number for setting canceling Call Waiting feature Reference e 4 3 17 Call Waiting U M Parameter 46 Executive Busy Override Deny Set Cancel Default 733 Value Range 1 4 digits consisting of 0 9 or Description Function Specifies the feature number for setting canceling Executive Busy Override Deny feature Reference e 4 3 34 Executive Busy Override Deny U M Parameter 47 Pickup Dialing Program Set Cancel Default 74 Value Range 1 4 digits consisting of 0 9 X or Description Function Specifies the feature number for programming setting canceling Pickup Dialing feature Reference e 4 3 62 Pickup Dialing Hot L
36. Reference e 1 6 Originating Features F G Toll Restriction 284 Programming Guide Toll Restriction 6 3 TRS Exception Code Used to program a list of numbers that an extension is allowed to dial even if these numbers are listed in a TRS Deny Code Table Up to 200 TRS Exception codes can be assigned 6 2 TRS Exception Code Parameter TRS Level Default 6 Value Range 2 6 Description Function Specifies a TRS toll restriction level Reference e 1 6 Originating Features F G Toll Restriction Parameter Entry No Default 001 020 Value Range 001 200 in 20 entries increments Description Function Specifies a unit of 20 TRS Exception codes which apply to the TRS level selected Reference e 1 6 Originating Features F G Toll Restriction Programming Guide 285 Toll Restriction Parameter Dial Default Blank Value Range Up to 10 digits consisting of 0 9 X or Description Function Specifies the leading 10 digits of the telephone numbers which are excepted from the toll restriction Note e X can be used as a wild card character which substitutes any digit in its position Reference e 1 6 Originating Features F G Toll Restriction 286 Programming Guide ARS Automatic Route Selection Section 7 ARS Automatic Route Selection Programming Guide 287 ARS Automatic Route Selection 7 1 ARS Automatic Route Selection Used
37. by clicking Trunk Group Setting on this screen Reference None Programming Guide 103 System Parameter TRS Level Day Night Default Value Range Description Function Reference 1 1 8 Specifies the Toll Restriction level 1 8 for each COS number in Day Night mode respectively e 1 6 Originating Features F G Toll Restriction Parameter Account Code Mode Default Value Range Description Function Reference 104 Optional 1 Optional 2 Verify Toll 3 Verify All Specifies one of the following three Account Code Entry modes 1 Optional Option mode An extension user can enter any account code if needed 2 Verify Toll Verified Toll Restriction Override mode An extension user can enter a pre assigned account code to override toll restriction 3 Verify All Verified All Calls mode An extension user must always enter a pre assigned account code when making any of the following outside calls unless it has previously been stored in memory e Last Number Redial e Saved Number Redial lt PT only gt e System Speed Dialing e One Touch Dialing lt PT only gt e Station Speed Dialing e Trunk Access Manual Dialing e 1 3 System Features F G Account Code Entry e 4 3 2 Account Code Entry U M Programming Guide System Parameter Switching Day Night Mode Default Disable Value Range 1 Enable 2 Disabl
38. card 16 BRI PRI23 card Value Range 0 16 digits Description Function Specifies the number of digits received from a DID or DID ISDN trunk Assignable only when Incoming Type is set to DID or DID ISDN Note e Incase of the following cards a maximum number of digits to be received is limited to 7 digits DID T1 DID Reference e 1 5 Attended Features F G Direct Inward Dialing DID e 2 3 ISDN Attended Features F G Direct Inward Dialing DID Programming Guide Line Parameter Wink Signal Time out Default Value Range Description Function Reference 1024 ms 64 ms 128 ms 256 ms 512 ms 1024 ms 2048 ms 4096 ms 8128 ms SIAR RYN Specifies the length of time in milliseconds that the system is to wait for the Wink Signal after seizing the trunk Assignable only when Start Signal Type is set to Wink the case of the DID card is excluded e 3 1 TIE Line Features F G TIE Line Service Parameter Start Signal Type Default Value Range Description Function Reference Programming Guide Wink 1 Immediate 2 Wink Specifies the start signal type for a DID and TIE E amp M trunk 1 Immediate The system sends the dialing digits to CO after waiting for the time length determined by First Dial Timer in Card Properties screen of the corresponding trunk card For information on Card Properties screen please refer to Card Type in Se
39. is specified in Group Type programming Reference e 1 3 System Features F G 190 Operator Group e 1 6 Originating Features F G Operator Call Programming Guide Group 3 5 1 Destination for Incoming Group You can assign up to 72 extensions or Extension Groups or both per Incoming Group so that an incoming CO call rings multiple extensions simultaneously Destination for Incomine Group 1 No DN Ringing Type 28 El immesate F Parameter Destinations DN Default Blank Value Range 3 4 digits consisting of 0 9 Description Function Specifies extensions or Extension Groups or both that you are going to assign to the specified Incoming Group Notes e DNof VPS port cannot be assigned as a mailbox number and an Incoming Group destination e Only DN of an extension or FDN of an extension group can be assigned as an Incoming Group destination e A single extension can be assigned to up to eight different Incoming Groups at a time Reference e 1 3 System Features F G Programming Guide Flexible Numbering 2 3 Numbering Plan P G 191 Group 192 Parameter Destinations Ringing Type Default Value Range Description Function Reference Immediate WN Immediate l ring Delay 3 ring Delay 6 ring Delay 5 No Ring Specifies the ringing delay of the calls arriving at extensions whose Group Type programming is specified as DIL 1 N 1
40. 0 60 s Description Function Extension port Specifies the maximum time allowed to the system after receiving the notification of call disconnection from ISDN before replying to it Reference None Parameter T07 Default 10s Value Range 0 60 s Description Function Extension port Specifies the maximum time allowed to the system after receiving the request of call disconnection from ISDN before replying to it Reference None Parameter CO Qsig Master PRI only Qsig Slave PRI only T200 Default ls Value Range 1 5 s Description Function Specifies the maximum time that the system waits after sending the L2 command to ISDN before receiving the reply to it Reference None Parameter CO Qsig Master PRI only Qsig Slave PRI only T203 Default 10s Value Range 1 60 s Description Function Specifies the time to detect no communication status of L2 Reference None Programming Guide 39 Configuration 40 Parameter CO Qsig Master PRI only Qsig Slave PRI only T302 Default 10 s BRD 15 s PRI23 Value Range 2 30 s Description Function Specifies the maximum time allowed between each digit on an incoming call Applies to the overlap receiving Reference None Parameter CO Qsig Master PRI only Qsig Slave PRI only T303 Default 5 s BRI 4 s PRI23 Value Range 2 12 s Description Function Specifies the maximum time that the system waits after sending the SETUP call setting message to
41. 2 Immediate An extension rings immediately 1 ring Delay An extension rings in 1 ring delay timing 3 ring Delay An extension rings in 3 ring delay timing 6 ring Delay An extension rings in 6 ring delay timing No Ring An extension does not ring e 1 3 System Features F G DIL 1 N Group e 1 13 Audible Tone Features F G Ringing Delayed Programming Guide Group 3 6 OGM Group Used to assign parameters for OGM Groups 1 8 OGM resources on the DISA card can be grouped together as an OGM Group Parameter Group No Default 1 Value Range 1 8 Description Function Specifies the OGM Group 1 8 which you are going to program Reference None Parameter FDN Default Blank Value Range 3 4 digits consisting of 0 9 Description Function Specifies the FDN Floating Directory Number for each OGM group Reference e 1 3 System Features F G Floating Station Programming Guide 193 Group 194 Parameter DN Refer Default Value Range Description Function Displays the list of DNs FDNs which are already assigned to the extensions system resources Reference None Parameter Tenant No Default 1 Value Range 1 8 Description Function Specifies the tenant 1 8 to which you are going to assign this OGM Group Reference e 1 3 System Features F G Tenant Service 2 2 Tenant P G Parameter OGM Type Def
42. 4 3 2 Account Code Entry U M Parameter TRS Level Default None Value Range None 1 6 Description Function Specifies the TRS toll restriction level for each account code Note e TRS level appended to each account code applies to the call in conjunction with Toll Restriction Override by Account Code Entry feature Reference e 1 3 System Features F G Programming Guide Account Code Entry e 1 6 Originating Features F G Toll Restriction Override by Account Code Entry e 4 3 2 Account Code Entry U M 259 Features 5 7 Special Carrier Code 260 Used to program a list of up to 100 Special Carrier Codes 5 6 Special Carrier Code Code No Max 10 Digits 5 6 Special Carrier Code x Parameter Code Default Blank Value Range Up to 10 digits consisting of 0 9 x or X Description Function Specifies special carrier access codes Notes e This assignment allows the system to recognize the user dialed special carrier code in order to insert the necessary pause and to apply toll restriction e X can be used as a wild card character which substitutes any digit in its position Reference e 1 6 Originating Features F G Toll Restriction Toll Restriction for Special Carrier Access Programming Guide Features 5 8 Absent Message Used to program a list of up to nine absent messages An absent message if set by the extension user is displayed on the cal
43. 96 Specifies COS Class of Service Level for each User Code 2 4 Class of Service COS P G 263 Features 5 10 VPS Integration 5 10 1 VPS Integration 1 2 Used to assign Integration Code and Voice Mail Command for VPS Integration 5 10 VPS Integration 1 2 stovrsiiearaton 2s ak teow Cones Ho Integration Code When DTMF tone Integration is activated the KX TD500 informs the VPS Voice Processing System of the status of the call busy answered ringing etc by sending a code with DIMF tone before sending the normal call progress tone busy tone ringback tone etc These codes enable the VPS to immediately recognize the current status of the call and improve its call handling performance Parameter Integration Code Ringback Tone Default 1 Value Range Up to 3 digits consisting of 0 9 or Description Function Specifies the Ringback Tone code Sent to the Voice Mail port when the extension dialed is ringing Reference e 1 3 System Features F G Integration VPS 264 Programming Guide Features Parameter Integration Code Busy Tone Default 2 Value Range Up to 3 digits consisting of 0 9 or Description Function Specifies the Busy Tone code Sent to the Voice Mail port when the extension dialed is busy Reference e 1 3 System Features F G Integration VPS Parameter Integration Code Reorder Tone Default 3 Va
44. Call 1 17 Display Features F G Display Date and Time 3 2 1 000 Date and Time Set U M Parameter Minute Default 00 Value Range 00 59 Description Function Specifies the minute in two digits by entering the value directly Reference 1 8 Ringing Features F G Programming Guide Timed Reminder Wake Up Call Timed Reminder Remote Wake Up Call 1 17 Display Features F G Display Date and Time 3 2 1 000 Date and Time Set U M 333 Maintenance Parameter AM PM Default AM Value Range AM PM Description Function Selects AM PM by clicking the small triangle Reference 1 8 Ringing Features F G Timed Reminder Wake Up Call Timed Reminder Remote Wake Up Call 1 17 Display Features F G Display Date and Time 3 2 1 000 Date and Time Set U M Summer Time Daylight saving Time Setting Note The start and end dates of the summer time cam be programmed The system clock will be adjusted one hour forward or backward at 2 00 AM of the programmed date if enabled It means 2 00 AM will become 3 00 AM on the start date of the summer time and 2 00 AM will become 1 00 AM on the end date If Timed Reminder or Day Night Switching Mode feature is set between 1 00 AM and 3 00 AM it may not work properly Parameter Setting Default Disable Value Range 1 Disable 2 Enable Description Function Enables or disables the automatic adjustment of the clock fo
45. Call Waiting v assignable Programming Guide 167 Group Applicability of Group Types to Overflow Destinations Overflow Destination Group DN External OGM Extension Phantom RMT Incoming Type Pager Group Group Extension Group None Terminate Vv Circular Y Operator va Vv va a VM Vv AA Vd UCD Y Y Vv Y W v assignable When DIL 1 N is specified in Group Type programming of Incoming Group this feature does not work 168 Programming Guide Group Extension Group Copy Used to copy a part of or all settings of a certain Extension Group to all other Extension Groups at a time You can also specify one or several Extension Groups as the copy destination Extension Group Copy M fe Dy ode a Gyeriow Way fn Gyeriowy Might fa Gyeriow inner garir miisi yates poeeeeee eo O G U S eo E soeeweeee ef Copying the Extension Group Parameters to Other Extension Groups 1 Edit the parameters of the copy source Extension Group and save it 2 Point to Copy on 3 2 Extension Group screen of the copy source and click e Extension Group Copy screen is displayed e The current Extension Group copy source number is shown as Copy from Extension Group 1 128 3 Select the Extension Group parameters to copy in Copy Item field e On
46. Description Function Specifies the FDN Floating Directory Number for each Phantom button Note e A single Phantom extension number can be assigned to multiple extensions so that the caller can ring a group of extensions simultaneously Reference e 1 3 System Features F G Floating Station e 2 2 3 Flexible Button Assignment U M e 3 2 5 005 Flexible CO Button Assignment U M Parameter DN Refer Default Value Range Description Function Displays the list of DNs FDNs which are already assigned to the extensions system resources Reference None Programming Guide 255 Features 5 4 Emergency Dial Code Used to program a list of up to 10 emergency numbers that any extension in the system can dial at any time regardless of dialing restrictions 5 3 Emergency Dial Code Fsemergenoyoatcode z ok toy canei Hoe Parameter Dial Default 1 911 Others Blank Value Range Up to 24 digits consisting of 0 9 Description Function Specifies emergency telephone numbers that can be dialed from any extension regardless of restrictions imposed by Toll Restriction Account Code Verified mode or Electronic Station Lockout Reference e 1 6 Originating Features F G Emergency Call e 4 3 31 Emergency Call U M 256 Programming Guide Features 5 5 Quick Dialing Used to store up to eight Quick Dialing numbers 5 4 Quick Dialing
47. Function Specifies the physical number of DLC DHLC card to which VPS is connected as extensions Note e The first DLC DHLC card will support jacks 1 to 8 of the first TVS300 system A second card will support jacks 9 to 12 of the TVS300 system A third and fourth card are needed to support a second TVS300 system which is fully configured Reference e 1 3 System Features F G Integration VPS e 1 2 Slot Assignment P G 60 Programming Guide Configuration Parameter Type Default None Value Range 1 None 2 TVS75 3 TVS100 4 TVS200 5 TVS80 110 200 1 200 2 6 TVS300 Description Function Specifies the model number of the Panasonic Voice Processing System which will be connected to the VPS card Note e Please select TVS200 1 if HDD Hard Disk Software Version of your TVS200 is 2 00 or later Reference e 1 3 System Features F G Integration VPS Parameter Jack No Default Display only Value Range Description Function Displays the Jack No of VPS Reference e 1 3 System Features F G Integration VPS Parameter Port No Default Blank Value Range 1 16 DLC card or 1 8 DHLC card Description Function Specifies the extension port to which the VPS DPT jack is to be connected Notes e This program tells the system which extension port is connected to the Panasonic Voice Processing System This allows the system to send the proper Digital Integration information to these por
48. Guide Call Transfer e 4 3 16 Call Transfer U M 125 System 126 Parameter 2 SLT On hook with consulting held call Default Consulting Hold Value Range 1 Consulting Hold 2 Disconnect Description Function Specifies the result of pressing the switchhook lightly and then replacing the handset during an outside call This setting applies to SLT users only Reference e 1 10 Holding Features F G Consultation Hold Parameter 3 FLASH button operation while CO talking Default Release the trunk Value Range 1 Release the trunk 2 Don t release the trunk Description Function Specifies the result of pressing the FLASH button on PT during an outside call Reference e 1 12 Conversation Features F G External Feature Access Parameter 4 FLASH button operation when Don t release the trunk is selected at 3 Default Disconnect and hear CO dial tone Value Range 1 Disconnect and hear CO dial tone 2 Sending EFA signal Description Function Specifies the result of pressing the FLASH button on PT during an outside call when Don t release the trunk is selected in 3 FLASH button operation while CO talking Reference e 1 12 Conversation Features F G External Feature Access Programming Guide System Parameter 5 Limited call duration Default Both calls Value Range 1 Outgoing call only 2 Both calls Description Function Limited call duration is a system programmable fea
49. H Description Function Specifies the AA Automated Attendant Service command If AA Service is set to Start by System Programming this command is sent to a VM port when an incoming CO call is answered by the VM port Reference e 1 3 System Features F G Integration VPS Parameter Voice Mail Command VM Service Default 6 Value Range Up to 16 digits consisting of 0 9 x or H Description Function Specifies the VM Voice Mail Service command This command is transmitted preceding the Get Message command above This is effective to switch to a VM port when an AA port lights the MESSAGE indicator This command is also transmitted preceding the Leave Message command when Operator transfers a call to an extension and then it is forwarded to an AA port so that the AA port can be switched to VM port temporarily Reference e 1 3 System Features F G Integration VPS Programming Guide Features 5 10 2 VPS Integration 2 2 Used to assign optional parameters for VPS Integration 5 10 VPS Integration 2 2 t 5 10 YPS Integration 2 2 Parameter DTMF signal duration Default 80 ms Value Range 1 80 ms 2 160 ms Description Function Specifies the duration of the DTMF signals sent to the Voice Mail ports Reference e 1 3 System Features F G Programming Guide Integration VPS 269 Features 270 Parameter Pause timing before sending DTMF signal Follow on ID
50. ID Code transmitted from CO is found in the Caller ID Code Table the caller s ID Code or a name given to the code is displayed on the display PT allowing the called party to recognize the caller before answering a call If the network provides telephone number only the system searches for the matching name from the Caller ID Code Table If the matching name is found the system will display both the telephone number and the name 5 12 Galler ID Registration Tenant No RE Entry No 0001 001 0 Import from Sys Speed Dial No Name Max 16 Characters Number Max 24 Digits 5 12 Caller ID Registration OK Apply Cancel Help Import from System Speed Dial Provides quick registration of Caller ID names and numbers Up to 1000 System Speed Dial data names and numbers stored in 5 1 System Speed Dialing screen can be copied to 5 12 Caller ID Registration screen at once with a simple operation 276 Programming Guide Features Operation a Specify the Tenant No in 5 12 Caller ID Registration screen e This determines the tenant no of the System Speed Dial Data to be copied b Click Import from Sys Speed Dial on 5 12 Caller ID Registration screen e The message W5022 Existing entries will be lost Do you wish to continue is displayed e If you want to cancel the operation click Cancel c Click LOK to continue the operation
51. Intercept Routing 2 Recall 3 Extension Call 4 Operator Setting Ringing Type Single 3 4 Paging Group Program Default Paging Group No 1 Extension Group No Paging Group No 1 No 1 1 No 2 128 Others None Paging Groups No 2 16 All None 3 5 Incoming Group Program Default Group No 1 Copy FDN Blank DN Refer Group Type DIL 1 N Overflow Setting Destination Day Night Blank Overflow Setting Timer None Mailbox No Blank FWD DND Mode Enable Search Mode UCD 372 Programming Guide Default Values Program Default Calls to Empty Group Disable UCD Setting Time Table No None UCD Setting FWD No Answer Disable UCD Setting Auto LOGOUT Mode Disable UCD Setting Supervisor Extension Blank UCD Setting UCD Call Waiting Enable Operator Setting Call Priority CO Call 1 Intercept Routing 2 Recall 3 Extension Call 4 Operator Setting Ringing Type Single 3 5 1 Destination for Incoming Group Program Default Destinations DN Blank Destinations Ringing Type Immediate 3 6 OGM Group Program Default Group No 1 FDN Blank DN Refer Tenant No 1 OGM Type DISA Security Mode Trunk DISA built in Automated Attendant Tables Dial Blank 0 Dial 9 Programming Guide 373 Default Values 4 Li
52. NAS S oE aae os E EVES 258 Programming Guide 3 Table of Contents 5 7 Special Carrier Code cccceccccsctscossccccosseosscssecsscccseassccesesacessssecetesseesecetsssccerseaccersnsescense 260 59 Absent MOSSa Se Sane ce cesceniseccessanses a are a Eor Ea Ar Sa PASE Eara RS Aa 261 5 9 DISA TIE User Code seccccccccccsecccesesccsesssssecsvsscscdsoesstscetcccecessectessectesssecteesessveccsssecesesus 262 STO VPS Integration ciiciciecvssstssosesnessecebessesecovosssennsosecovenscesuessdsbesoosessenss acoeseseavesssocessssees 264 5 11 Caller ID Modification ac sseseesseecressercesiresceiseesscsipesscosseess seris ss eose tcsso sec ses lecs toessoss 273 5 12 Caller ID Resis tration ices cicscisssesaics oroo aan naar sanadzesseadsascsescaseessesesvaneasevensazeaonte 276 5 13 UCD Time Table iii csecccsseccssccsessscecsssneceseueceesecectesecscccsedscsesedscccsssccsessccesevecsesevescoesvse 279 6 Toll Restriction sosesooooooossssesooosososesoosossssssosssosssossssessssssssseeses 2O L GOL Tol RES tri Ct OD sees cessiecctasceccccsunsicscasisssescesevestecssseaustecsssadedsssccessssueceuseedescsvetsascecssvesessenes 282 6 2 TRS Deny COG scccscscscesstvvevssestesosossoesssvecsstesvestesevessese sescesvipeoscseseonteeeessontesssnsvenecssuees 283 6 3 TRS Exception Code isisssiscvsctscenaccsessssvocsssecssevsssonscvooscensaessnevesessessncsdsteveodsvseassexsooseas 285 7 ARS Automatic Route Selection cccccccssssssscccscss
53. Network Specific 6 Subscriber Description Function Specifies the Type of Number applied to the outgoing incoming CO calls via ISDN Reference None Programming Guide Line Parameter CLIP Number Public Default Value Range Description Function Reference Blank Up to 16 digits consisting of 0 9 or Specifies a CLIP number used for the incoming outgoing calls via Public Switched Telephone Network to each ISDN extension Notes e When an extension user makes an outside call using an ISDN BRI line the number stored in DN lt Section 1 2 9 Card Properties BRI SPID DN in the Programming Guide gt is displayed on the telephone of the other party as the CLIP number e Specify the registered Central Office calling number for correct operation of CLIP e 2 2 ISDN Originating Features F G Calling Line Identification Presentation CLIP e 4 3 19 Calling Line Identification Presentation CLIP U M Parameter CLIP Number Private Default Value Range Description Function Reference Programming Guide Blank Up to 16 digits consisting of 0 9 or Specifies a CLIP number used for the incoming outgoing calls via Private Network to each ISDN extension Notes e When an extension user makes an outside call using an ISDN BRI line the number stored in DN lt Section 1 2 9 Card Properties BRI SPID DN in the Programming Guide gt is displayed on the telephone
54. Number Only DN of an extension or FDN of an extension group can be assigned as a Mailbox Number E4003 Invalid LCS playback password The LCS playback password must be 3 digits 0 9 E4004 Invalid Call Log lock password The Call Log lock password must be 3 digits 0 9 E4005 Invalid Station Lock password The Station Lock password must be 3 digits 0 9 E4006 Specify trunk line no Trunk line no must be specified when Single CO key is assigned E4007 Single CO key duplicated Please assign the Single CO key that has the different CO physical number on one PT E4008 Invalid directory number for DSS DN or VTR key Only DN of an extension can be assigned as DSS DN or VTR key E4009 DSS DN key duplicated Two DSS keys cannot have the same extension number E4010 Invalid directory number for PHANTOM key Only FDN of phantom extension can be assigned to phantom key number E4011 Cannot assign PDN key without assigning PDN key on CO 01 The first PDN key should be assigned on CO 01 E4012 Cannot change PDN key on CO 01 while other PDN or SDN keys exist Please change PDN key on CO 01 to another key type after deleting all PDN and SDN assignments 344 Programming Guide Programming Error Messages Error Message Error Code Description E4013 Cannot assign SDN key without assigning PDN key An SDN button should have its associated PDN button E4014 Ca
55. Operator Call Programming Guide Group Parameter Calls to Empty Group Default Disable Value Range 1 Enable 2 Disable Description Function Allows for calls to empty all Logout Operator or UCD Groups to be queued If enabled calls will be queued to the group If disabled the extension will receive a reorder tone and the CO call will be transferred to the overflow destination immediately Assignable only when Operator or UCD is specified in Group Type programming Reference e 1 3 System Features F G Incoming Group Operator Group e 1 5 Attended Features F G Uniform Call Distribution UCD Parameter UCD Setting Time Table No Default None Value Range None 1 32 Description Function Specifies the UCD Time Table 1 32 for the UCD Group Reference e 1 3 System Features F G Programming Guide Incoming Group e 1 5 Attended Features F G Uniform Call Distribution UCD 187 Group Parameter UCD Setting FWD No Answer Default Value Range Description Function Reference Disable 1 Disable 2 Enable Specifies the treatment of the call which is not answered by the extension in the UCD group within a specified period of time Call Forwarding No Answer Time 1 Disable The call continues to ring the current destination extension 2 Enable The system transfers the call to an idle extension in the group e 1 3 System Features F G
56. Out of Service E1056 Value of Max must be larger than value of Min Detection time value of Tone ON Time Tone OFF Time Max must be larger than that of Tone ON Time Tone OFF Time Min E1058 Assign ISDN Ext under 1 8 BRI Port Assignment When you open 4 6 ISDN Extension Line screen an ISDN extension must be assigned on 1 8 BRI Port Assignment screen E1059 VPS card duplicated Each physical number of the VPS Card Jack 1 8 and VPS Card Jack 9 12 must be assigned uniquely E1060 You have exceeded the limit of VPS DPT port per DLC card There is a limit of 8 VPS DPT ports per DLC card E1061 You have exceeded the shelf limit of VPS DPT port There is a limit of 16 VPS DPT ports per shelf E2001 Invalid time format Please specify the time as Hour 0 1 12 Minute 0 0 59 E2002 Assign the time of beginning and ending in a pair Cannot assign just the start time or just the end time of Lunch Break service Both must be assigned as a pair 342 Programming Guide Programming Error Messages Error Message Error Code Description E2005 Maximum entry number of System Speed Dialing exceeded The system provides up to 1000 tenant 2000 system of System Speed Dialing entries available to all extension users E2006 Cannot change System Speed Dialing Entries Maximum Please delete System Speed Dialing entries until there is less than the setting you want
57. Range Description Function Displays the list of DNs FDNs which are already assigned to the extensions system resources Reference None Programming Guide Group Parameter Tenant No Default 1 Value Range 1 8 Description Function Specifies the tenant 1 8 to which the Extension Group is assigned Required when Tenant Service is employed Reference 1 3 System Features F G Tenant Service 2 2 Tenant P G Parameter Overflow Setting Destination Day Night Default Blank Value Range 3 4 digits consisting of 0 9 Description Function Specifies the destination extension where the call is transferred to when all extensions in the Extension Group are unavailable or logged out in Day Night mode respectively Reference None Parameter Overflow Setting Timer Default None Value Range None 5 180 s in 5 s increments Description Function Specifies the length of time in seconds the system is to wait before transferring the call in the waiting queue to the Overflow Destination Assignable only when Operator is specified in Group Type programming Note e If None is specified the call is transferred to the Overflow Destination immediately Reference 1 3 System Features F G Programming Guide Operator Group 171 Group Parameter Group Type Default Group No 126 VM Group No 127 AA Group No 128 Operator Others None Value Range 1 8 I
58. Range 001 800 in 20 entries increments Description Function Specifies the entry number which you are going to program Reference e 1 6 Originating Features F G 290 Automatic Route Selection ARS Programming Guide ARS Automatic Route Selection Parameter Dial Default Blank Value Range Up to 10 digits consisting of 0 9 or X Description Function Specifies the leading 10 digits of the telephone number which will be routed by ARS procedure Note e X can be used as a wild card character which substitutes any digit in its position Example 1 Leading Digits 1800 gt ARS Plan 1 Leading Digits 1 x x x gt ARS Plan 2 If the user dialed number is 1800 the system selects ARS Plan 1 Example 2 Leading Digits 1800 ARS Plan 1 Leading Digits 1 x gt ARS Plan 2 If the user dialed number is 1800 the system selects ARS Plan 2 Reference e 1 6 Originating Features F G Automatic Route Selection ARS Parameter Routing Plan No Default None Value Range None 1 48 Description Function Specifies the Routing Plan 1 48 which is used for routing the telephone number registered in Dial field above Reference e 1 6 Originating Features F G Programming Guide Automatic Route Selection ARS 291 ARS Automatic Route Selection 7 4 Routing Plan 292 Used to specify the Trunk Group number 1 48 and Modified Digit Table number 1 48 to be used for each route
59. Speed Dialing number Reference e 4 3 72 Station Speed Dialing U M Parameter 22 Speed Dialing Station Programming Default 30 Value Range 1 4 digits consisting of 0 9 or Description Function Specifies the feature number for programming Station Speed Dialing numbers at each extension Reference e 4 3 72 Station Speed Dialing U M Parameter 23 Doorphone Call Default 31 Value Range 1 4 digits consisting of 0 9 or Description Function Specifies the feature number for making a call to a doorphone Reference 4 3 29 Doorphone Call U M Parameter 24 External Paging Default 32 Value Range 1 4 digits consisting of 0 9 X or Description Function Specifies the feature number for making a paging announcement through External Pagers Reference e 4 3 55 Paging U M Programming Guide System Parameter 25 External Paging Answer TAFAS Answer Default 42 Value Range 1 4 digits consisting of 0 9 or Description Function Specifies the feature number for answering paging announcements through External Pagers or TAFAS Trunk Answer From Any Station calls Reference e 4 3 56 Paging Answer U M e 4 3 78 Trunk Answer From Any Station TAFAS U M Parameter 26 Station Paging Default 33 Value Range 1 4 digits consisting of 0 9 x or Description Function Specifies the feature number for making a paging announcement through the built in speakers of PTs Reference e 4 3 55 Pagin
60. TIE line feature e 4 3 16 Call Transfer U M e 1 11 Transferring Features F G Call Transfer Parameter Incoming Group FWD Default Value Range Description Function Reference 112 Disable 1 Disable 2 Own Group s 3 Any Group Enables or disables setting Incoming Group FWD feature The extension allowed by this setting can set Call Forwarding feature to an Incoming Group so that all calls to the Incoming Group can be forwarded to specified Incoming Group or Extension Group 1 Disable Disables this feature 2 Own Group s Enables forwarding all calls to other Incoming Groups or Extension Groups Only its own group s can be set as the Call Forwarding setting extension 3 Any Group Enables forwarding all calls to other Incoming Groups or Extension Groups Any group can be set as the Call Forwarding setting extension e 1 11 Transferring Features F G Call Forwarding All Calls to an Incoming Group e 4 3 10 Call Forwarding All Calls to an Incoming Group U M Programming Guide System 2 5 System Timer 2 5 1 System Timer 1 2 Used to assign various system timers remmen d Ge e cenest Hee Parameter Hold Recall Time Default 60 s Value Range 0 240 s Description Function Specifies the length of time in seconds that the system is to wait before alerting the extension user who held the call by Held Call Reminder ringing The reminder to
61. Then set System Speed Dialing Entries Maximum once again E2007 Invalid directory number for manager extension Only DN of an extension can be assigned as a manager extension FDN cannot be assigned E2008 Feature number is too long Feature numbers Hundred Block Extension or Other PBX can be set as the leading 1 or 2 digits of the extension number E2009 Cannot delete the Hundred Block Extension which is currently in use as DN or FDN Cannot delete the hundred block number It s already used as DN or FDN Please delete the hundred block number after you remove the registrations of DN or FDN E2010 Feature number duplicated Feature numbers can be from 1 to 4 digits and shouldn t be any conflicts The following are examples of feature number conflicts Examples N and NX NXX NM and NML NL is allowed E2011 Out of range Overflow Timer should be assigned in the range of Second 5 180 None shows that Overflow Timer doesn t work E2012 Trunk group number duplicated Each trunk group in the Local Hunt Sequence must have a unique number E2013 Invalid directory number for Operator FDN Only FDN of an extension group and incoming group can be assigned as an Operator FDN E3001 Invalid directory number for intercept destination There are seven possible destinations for intercepted calls 1 An extension 2 an external pager TAFAS 3 an OGM group 4 an extension group 5 an incoming g
62. Trunk Group to all other Trunk Groups at a time You can also specify one or several Trunk Groups as the copy destination Copying the Trunk Group Parameters to Other Trunk Groups 1 Edit the parameters of the copy source Trunk Group and save it 2 Point to Copy on 3 1 Trunk Group screen of the copy source and click e Trunk Group Copy screen is displayed e The current Trunk Group copy source number is shown as Copy from Trunk Group 1 48 Trunk Group Copy Copy from Trunk Group 1 m Copy Item m Destination Trunk Group M Ini Vv Intercept Destination Night m4 r 13 T 26 Eo V PBX Dial Tone m maz M26 38 iV Line Hunting Order gl r 15 r 39 Vv Tenant Noy r 4 gy 28 r 40 Vv Dizconpectnatime rs rar r 29 rat V Pause Time IV Pause Time Before Flash Signal 6 T 18 30 42 V Flash Time z E mo 43 V PBXAccess Code rs rl 20 l 32 D 44 z ae cecal go og go me Continuous Signal Detection V Silence Detection ma a a a IV PBX Ringback Tone Bo 23 r35 a gq 24 T 36 rT 48 IV Numbering Plan ID IV Type of Number IV Max Dial No after EFA Signal asaan IV ISDN Progress Tone Mode Execute Cancel Help IV IRNA for TIE Line 3 Select the Trunk Group parameters to copy in Copy Item field e Items marked with are copied 4 Point to Select All in the Destination Trunk Group field and click e All displayed Trunk Group Nos will be marked with v e You
63. a trunk line after detecting loop current from the local CO Reference 3 2 Trunk Group P G Parameter 29 Card CODEC Default Mu Law Value Range 1 Mu Law 2 A Law Description Function Specifies the PCM Pulse Code Modulation conversion mode of KX T96xxx series trunk and extension cards Note e This setting is required only when XMX for Mexico type KX T96xxx series trunk and extension cards are installed in the system In this case select A Law Reference None Parameter 30 Net CODEC Default Mu Law Value Range 1 Mu Law 2 A Law Description Function Specifies the type of PCM Pulse Code Modulation conversion mode compatible with the Digital Network to which the system is connected Note e The change of this parameter is activated after resetting the system Reference None Programming Guide System 2 8 4 System Option 4 Cc 7 System Option 4 Enable 31 Answering Call Waiting call by SLT hooking 32 Whisper OHCA to extensions other than Disable sed to assign system option parameters No 31 No 49 THAR C Enable Disable 33 FWD DND lamp pattern FWD Flash DND On 34 ELCOT LCOT Busy out Loop Relay for H 35 GCOT Busy out Loop Relay OFF RING OPEN 36 Tone Mode Type 1 x 37 Ring Mode Type 1 x 38 First Digit Time out Process Dont release the trunk x 42 DPT Ringer OFF Enable C Disable m41
64. automatically when the extension user goes off hook to make a call Reference e 2 2 12 Preferred Line Assignment Outgoing U M Programming Guide Line Parameter Preferred Line Outgoing Key No Default Blank Value Range 1 24 Description Function Specifies the CO button to which the extension is connected when the extension user goes off hook to make a call This assignment is required when Prime Line CO is specified in Preferred Line Outgoing programming Reference e 2 2 12 Preferred Line Assignment Outgoing U M Parameter Preferred Line Incoming Default Ringing Line Value Range 1 No Line 2 Ringing Line 3 Prime Line ICM PDN 4 Prime Line CO Description Function Specifies the line to which the extension is connected when the extension user goes off hook to answer a call Reference e 2 2 11 Preferred Line Assignment Incoming U M Parameter Preferred Line Incoming Key No Default Blank Value Range 1 24 Description Function Specifies the CO button to which the extension is connected when the extension user goes off hook to answer a call This assignment is required when Prime Line CO is specified in Preferred Line Incoming programming Reference e 2 2 11 Preferred Line Assignment Incoming U M Parameter Pickup Dialing Mode Default Disable Value Range 1 Enable 2 Disable Description Function Specifies whether Pickup Dialing feature is e
65. consisting of 0 9 or Description Function Specifies the number to be added to the telephone number sent from the Central Office by Caller ID Service to make up a telephone number for local call The number is added to the beginning of the received digits Reference e 1 5 Attended Features F G Caller ID Service Parameter Long Distance Call Digits to delete Default 0 Value Range 0 9 Description Function Specifies the number of digits to be deleted from the telephone number sent from the Central Office by Caller ID Service to make up a telephone number for long distance call Digits are removed from the beginning of the received digits Reference e 1 5 Attended Features F G Caller ID Service Programming Guide Features Parameter Long Distance Call Number to be added Default 1 Value Range Up to 4 digits consisting of 0 9 or Description Function Specifies the number to be added to the telephone number sent from the Central Office by Caller ID Service to make up a telephone number for long distance call The number is added to the beginning of the received digits Reference e 1 5 Attended Features F G Programming Guide Caller ID Service 275 Features 5 12 Caller ID Registration 5 12 1 Caller ID Registration Used to assign the Caller ID code identification code of the calling party to utilize Caller ID Service provided by a specific Central Office CO If an
66. destination in the system 1 DIL Incoming CO calls are routed by DIL Direct In Lines 1 1 or 1 N feature 2 DID Incoming CO calls are routed by DID Direct Inward Dialing feature 3 DID ISDN Incoming CO calls are routed by ISDN DID Direct Inward Dialing feature 4 MDN Incoming CO calls are routed by ISDN MDN Multiple Directory Number feature 5 TIE Incoming CO calls are routed by TIE Line feature Programming Guide Line Parameter Incoming Type Description Function lt Available selections and the default values per Card Type gt Card Type Selection Default BRI DID ISDN MDN DID ISDN DID DID DID TI TIE DIL TIE TIE LCOT GCOT DIL DIL ELCOT T1 LCO T1 GCO T1 DID DIL DID DID PRI23 TIE DIDUSDN DIDCSDN Note e n some cases the default cannot be changed Reference e 1 5 Attended Features F G Direct In Lines DIL Direct Inward Dialing DID e 2 3 ISDN Attended Features F G Direct Inward Dialing DID e 3 1 TIE Line Features F G TIE Line Service Programming Guide 203 Line 204 Parameter Dial Type Default DTMF 80 ELCOT GCOT LCOT TI DID card ISDN BRI PRI23 card Value Range 1 Pulse 10 10 PPS 2 Pulse 20 20 PPS 3 DTMF 80 80 ms 4 DTMF 160 160 ms 5 ISDN Description Function Specifies the dial type for each trunk line This is the dial type regardless of the dial mode
67. e 2 3 ISDN Attended Features F G Direct Inward Dialing DID Parameter 19 Destination Busy TIE Default Send busy tone Value Range 1 Send busy tone 2 Transferred to IRNA destination Description Function Specifies the treatment of TIE callers when they dial a busy extension Reference 3 1 TIE Line Features F G TIE Line Service Parameter 20 Off hook Monitor Default Enable Value Range 1 Enable 2 Disable Description Function Enables or disables Off hook Monitor feature on a system wide basis This feature allows a PT user on a handset call to let other people around him monitor the call by pressing the SP PHONE button Note e This setting applies to the following PT extensions only KX T7431 KX T7433 KX T7436 Reference e 1 12 Conversation Features F G Off Hook Monitor 4 3 51 Off Hook Monitor U M Programming Guide System 2 8 3 System Option 3 Used to assign system option parameters No 21 No 30 Programming Guide 133 System Message Waiting lamp patterns 1 2 The available message waiting lamp patterns are as follows Pattern 01 Pattern 02 Pattern 03 Pattern 04 Pattern 05 Pattern 06 134 ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF s Ve L28 lt _ gt 5 12 Programming Guide System Message Waiting lamp patterns 2 2 Pattern 07 Pattern 08 Patte
68. e 4 3 14 Call Pickup Deny U M Parameter Language Default English Value Range 1 English 2 French Description Function Specifies the language shown on a PANASONIC display PT The language is set for each extension so phones on the same system can display different languages Reference e 2 2 1 Bilingual Display Selection U M Parameter Station Lock Password Default Blank Value Range Fixed to 3 digits consisting of 0 9 Description Function Specifies the 3 digit password that lets the extension user lock and unlock the extension Electronic Station Lockout Reference e 1 6 Originating Features F G Electronic Station Lockout e 4 3 30 Electronic Station Lockout U M Programming Guide Line Parameter ISDN Bearer Mode Default Automatic Value Range 1 Automatic 2 Speech 3 3 1 KHz Audio Description Function Specifies the ISDN Bearer Mode on an extension basis Note e When Automatic Default is selected Bearer Mode is set automatically depending on the type of extension telephone as follows PT Speech SLT 3 1 KHz Audio ISDN extension depending on the bearer mode of the ISDN extension Reference e 2 1 ISDN Features F G Integrated Services Digital Network ISDN Parameter JOG Dial Speed Default Normal Value Range 1 Normal 2 High Description Function Specifies the rotation speed of the JOG Dial on the KX T7400 series PTs Reference None Programming Guide 221 Line
69. must be 3 or 4 digits E1016 Invalid directory number The entered DN doesn t match the numbering plan in 2 2 Numbering Plan screen E1017 Directory number already exists The entered DN or FDN already exists E1018 Directory number doesn t exist The entered DN doesn t exist E1019 Invalid directory number for paired extension of DSS console Only the DN of PT can be assigned as the DN for the paired extension of a DSS console E1020 You have exceeded the limit of DSS consoles per PT There is a limit of 8 DSS consoles per PT E1022 Assign the directory number before making the port INS In Service status An extension without a DN cannot be placed into service 340 Programming Guide Programming Error Messages Error Message Error Code Description E1023 Assign the directory numbers for EXT 1 and EXT 2 For the VPS port you must assign directory numbers for both voice mail numbers EXT 1 and EXT 2 These cannot be assigned individually E1024 Cannot assign the port which does not have VPS DPT attribute To be used as a VPS port this port must have the VPS DPT attribute in 1 3 Extension Port Assignment screen E1025 Specify the extension group number The extension group number of VPS port should be always assigned E1026 Port number duplicated Please assign the port number of TVS uniquely E1027 T1 card should be assigned to the slot no 1 5 or 9 T1 card
70. number for Trunk Busy out feature For Manager Operator only Reference e 4 4 12 Trunk Busy Out Setting U M Parameter 95 Walking Station Default 727 Value Range 1 4 digits consisting of 0 9 or Description Function Specifies the feature number for Walking Station feature Reference e 4 3 85 Walking Station U M Programming Guide 99 System 100 Parameter 96 CLIP Default 711 Value Range 1 4 digits consisting of 0 9 x or Description Function Specifies the feature number for selecting a CLIP Calling Line Identification Presentation number for an outside line or an extension Reference e 4 3 19 Calling Line Identification Presentation CLIP U M Parameter 97 CLIR CNIR Default 59 Value Range 1 4 digits consisting of 0 9 or Description Function Specifies the feature number for turning on off the CLIR Calling Line Identification Restriction and CNIR Calling Name Identification Restriction feature Reference e 4 3 20 Calling Line Identification Restriction CLIR Calling Name Identification Restriction CNIR U M Parameter 98 Reserved Reserved for future use Default Blank Value Range Description Function Reference Parameter 99 Dial Information CTI Default Blank Value Range 1 4 digits consisting of 0 9 X or Description Function Specifies the feature number for sending digits to the CTI application usually running on a PC connected to the PBX
71. of the extension telephone The dialing signals from any extension are converted to the dial type specified by this setting and transmitted to the trunk line lt Available selections and the default values per Card Type gt Card Type Selection Default BRI PRI23 ISDN ISDN DID DTMF 80 DTMF 80 ELCOT Pulse 10 Pulse 20 DTMF 80 DTMF 80 GCOT DTMF 160 Reference None Programming Guide Line Parameter Destination Day Night Lunch Break Default Value Range Description Function Reference Day Night 1001 Lunch Break Blank 3 4 digits consisting of 0 9 Specifies the destination for the trunk line whose Incoming Type is set to DIL The following numbers can be assigned as the destination Extension numbers FDNs Assignable only when DIL is specified in Incoming Type programming Note e When Incoming Type of the ISDN trunk line is set to DID ISDN you can specify the destination DN FDN as Destination In this case the destination DN FDN specified by this setting is available not that specified in 9 1 DID Dial Registration screen e 1 5 Attended Features F G Direct In Lines DIL e 2 3 ISDN Attended Features F G Direct Inward Dialing DID Parameter Subscriber Default Value Range Description Function Reference Programming Guide Blank Up to 16 digits consisting of 0 9 or Specifies the number which is used as the CLIP Calling Line Identif
72. of the other party as the CLIP number e Specify the registered Central Office calling number for correct operation of CLIP e 2 2 ISDN Originating Features F G Calling Line Identification Presentation CLIP e 4 3 19 Calling Line Identification Presentation CLIP U M 247 Line 248 Parameter COS No Primary Default 1 Value Range 1 96 Description Function Specifies the Primary COS Class of Service 1 96 to the ISDN extension Reference e 1 3 System Features F G Class of Service COS e 4 4 10 Switching COS U M Parameter COS No Secondary Default 1 Value Range 1 96 Description Function Specifies the Secondary COS Class of Service 1 96 to the ISDN extension Reference e 1 3 System Features F G Class of Service COS e 4 4 10 Switching COS U M Programming Guide Features Section 5 Features Programming Guide 249 Features 5 1 Features Used to assign parameters for various system features E TD500 Main 250 Programming Guide Features 5 2 System Speed Dialing Used to program a list of up to 1000 000 999 frequently dialed numbers per tenant Anyone in the same tenant can dial these numbers Up to 2000 Speed Dialing codes can be shared among tenants under the limitation of 1000 codes per tenant The maximum number of Speed Dialing numbers per tenant is specified in 2 1 Tenant screen You can import System Speed Dialin
73. pulse e 1 3 System Features F G T1 Carrier e 2 1 ISDN Features F G Integrated Services Digital Network ISDN Programming Guide Configuration Parameter Clock Configuration Priority 1 8 Default None or 101 314 T1 BRI PRI23 Value Range None 101 314 T1 BRI PRI23 Description Function Specifies the physical number of the T1 BRI PRI23 card that provides External Clock pulse to the system in priority order Note e You have to assign this parameter even if only one T1 BRI PRI23 card is installed When more than one T1 BRI PRI23 card is installed in the system each of them should be registered Reference e 1 3 System Features F G T1 Carrier Programming Guide e 2 1 ISDN Features F G Integrated Services Digital Network ISDN 51 Configuration 1 3 52 Trunk Port Assignment Used to assign each trunk port in the system to one of up to 48 trunk groups 1 2 Trunk Port Assignment f E i f zl E mm 1 2 Trunk Port Assignment ha m m F E m E amp c o ow 1 SS D v a s SS 1 Wagga Judd es HAA i Parameter Card No Default Value Range XXX YYY XXX Card No 101 314 YYY Card Type Description Function Specifies the physical number of the trunk card and its type which you are going to program Reference e 1 2 Slot Assignment P G Parameter Group No Defaul
74. should be assigned to the slot no 1 5 or 9 of basic shelf expansion shelf 1 and expansion shelf 2 E1028 Card type should be changed only in OUS Out of Service status Please make the card OUS Out of service status before deleting the card E1029 While copying properties more than 16 cards cannot be selected Please break the task into two sets E1030 Cannot change the Port Attribute when currently assigned as VPS port under 1 4 VPS DPT Port Assignment When the port which is assigned to VPS DPT port is changed to extension port please change the port after deleting the assignment in 1 4 VPS DPT Port Assignment screen E1031 Assign the channel type before making the port INS In Service status The port of T1 card cannot be made INS In Service status when the channel type of the port is not assigned E1032 Cannot change the status of the VPS port which is in auto configuration mode Please change the status of the VPS port after auto configuration E1033 Proper card for this feature is not installed in the system In order to use this feature proper card must be installed in the system And card must be assigned under Slot Assignment E1034 Both extensions B1 and B2 of 1st jack connected to VPS must be always assigned Both extensions B1 and B2 of 1st jack are used for communication between PBX and VPS E1035 Cannot remove VPS port while the status is INS In Service Please ma
75. status must be OUS Out of Service Card Properties 105 BRD Network Type Disable l DTMF Signal Duration 80 ms v Status Receive Disconnect C Ignore Inter digitPause 112 ms Line Mode Line L1 Mode L2Mode Access Mode El TE Power 1 Permanent x Permanent x P P Fixo x E SEDD 2 Permanent Permanent z P xo Fl Permanent Permanen miee Mio M il i SEDD SIDD SFD SF DDN SEDDI SIDD oeee a AU SEID r Software information Version Q3514A000906 g Check Sum even 6754 odd 4CFF Timer Setting Ok Cancel Help Parameter Network Type Default Display only Value Range National ISDN1 fixed Description Function Displays the ISDN type Reference None Parameter DTMF Signal Duration Default 80 ms Value Range 1 80 ms 2 160 ms Description Function Specifies the duration of the DTMF signals sent to ISDN Reference None Parameter DTMF Signal Inter digit Pause Default 112 ms Value Range 64 240 ms in 16 ms increments Description Function Reference 30 Specifies DTMF inter digit pause time None Programming Guide Configuration Parameter Status Message Default Enable Value Range 1 Enable 2 Disable Description Function Specifies whether to send the Status Message to ISDN or not Reference None Parameter Status Receive Default Disconnect Value Ra
76. 6 Value Range 1 4 digits consisting of 0 9 or Description Function Specifies the feature number for sending a switchhook flash to a host PBX or Centrex system This is useful when the host PBX offers for example Call Waiting call Reference e 4 3 35 External Feature Access U M Programming Guide 91 System 92 Parameter 39 Station Program Clear Default 790 Value Range 1 4 digits consisting of 0 9 or Description Function Specifies the feature number for Station Program Clear Reference e 4 3 71 Station Program Clear U M Parameter 40 Message Waiting Set Cancel Call Back Default 70 Value Range 1 4 digits consisting of 0 9 X or Description Function Specifies the feature number for setting canceling the Message Waiting indications This is also used to call back the party who left a Message Waiting indication Reference e 4 3 46 Message Waiting U M Parameter 41 OGM Playback Record Default 36 Value Range 1 4 digits consisting of 0 9 X or Description Function Specifies the feature number for recording playing back an OGM Outgoing Message For Manager Operator only Reference e 4 4 6 Outgoing Message OGM Record Playback U M Parameter 42 Call FWD Do Not Disturb Set Cancel Default 710 Value Range 1 4 digits consisting of 0 9 X or Description Function Specifies the feature number for setting canceling the Call Forwarding Do Not Disturb feature
77. A Panasonic Telephone Systems oiceSonic KX T D 500 www voicesonic com Phone 877 289 2829 Digital Super Hybrid System Programming Guide Panasonic KX TD500 KXTD500 KX TD500 TD500 N j Please read this manual before connecting the Digital Super Hybrid System and save this manual for future reference Thank you for purchasing the Panasonic Model KX TD500 Digital Super Hybrid System Introduction Introduction This Programming Guide is designed to serve as a technical reference for the Panasonic Digital Super Hybrid System KX TD500 It provides step by step instructions for performing system programming using the Maintenance Console software for a PC About the Other Manuals Along with this Programming Guide the following manuals are available Features Guide Describes every basic optional and programmable features of the KX TD500 System in alphabetical order User Manual Provides operating instructions for the end users using Proprietary Telephones PTs Single Line Telephones SLTs or DSS Consoles Installation Manual Describes information necessary for installing the hardware and system maintenance Note e Throughout this manual the term he or she his or her may be used In order to improve readability rather than continually use he she we have only used one of these terms The term he or she should be taken as being interchangeable Trademarks e Mic
78. AM RwWHN None Terminate Circular Ring Operator VM AA UCD Description Function Specifies the Group Type for each Extension Group This determines how the Extension Group handles the incoming calls directed to it 1 2 None No Group Type is specified Terminate Functions as a Station Hunting Group Terminate Circular Functions as a Station Hunting Group Circular Ring Functions as a Ring Group Operator Functions as an Operator Group e VM Functions as a VM Voice Mail Group AA Functions as an AA Automated Attendant Group UCD Functions as a UCD Uniform Call Distribution Group Reference 1 3 System Features F G 172 Extension Group Programming Guide Group Parameter FWD DND Mode Default Enable Value Range 1 Disable 2 Enable Description Function Specifies whether to enable or disable the FWD DND Call Forwarding or Do Not Disturb feature assigned on all extensions in the Extension Group Assignable only when Terminate Ring Circular or UCD is specified in Group Type programming Reference None Parameter Extension Call Hunting Default Enable Value Range 1 Enable 2 Disable Description Function Specifies whether station hunting feature works or not when the other party calls a busy extension in the group by dialing DN of the extension extension call Assignable only when Terminate or Circular
79. Button Assignment U M e 5 2 1 Station Programming U M 239 Line 4 5 Doorphone 240 Used to assign the destination extensions for incoming calls from doorphones 4 4 Doorphone Card No 112 DPH x Port No IN Tenant No fi x m Destination Day 3 4 Digits Toe oe im i G E M o H O H w H E G E 20 aj 2j E 23 ajf E spo p ajo 28 g af E ajf E m Destination Night 3 4 Digits m Fy Fy fF a Cn H O EEG EES H E Feel Feel M Tor oe a E g H a ss wD a sf O H af 28 B 29 30 4 4 Doorphone x OK Apply Cancel Help Parameter Card No Default Value Range XXX DPH XXX Card No 101 314 Description Function Specifies the physical number of a doorphone card which you are going to program Reference 1 2 Slot Assignment P G Parameter Port No Default 1 Value Range 1 4 Description Function Specifies the doorphone port which you are going to program Reference None Programming Guide Line Parameter Tenant No Default 1 Value Range 1 8 Description Function Specifies the tenant 1 8 to which the doorphone port is assigned Reference e 1 3 System Features F G Tenant Service e 1 12 Conversation Features F G Doorphone Call 2 2 Tenant P G Parameter Destination Day Night Default Blank Value Range 3 4 digits consisting of 0 9 Descr
80. CO calls Assignable for ELCOT GCOT LCOT T1 GCO and T1 LCO cards Reference e 1 3 System Features F G Calling Party Control CPC Signal Detection Programming Guide Line Parameter CPC Signal IN Detection Default Enable DID ELCOT GCOT LCOT T1 GCO T1 LCO card Value Range 1 Enable 2 Disable Description Function Specifies whether CPC Detection on incoming CO calls is enabled or disabled If enabled the system disconnects the line with the time set in program CPC Signal IN Detection Detection Time when the CPC signal is detected Reference e 1 3 System Features F G Calling Party Control CPC Signal Detection Parameter CPC Signal IN Detection Detection Time Default 400 ms Value Range 1 None 2 6 5 ms 3 2 75 x 8 ms Description Function Specifies the expected minimum duration for detecting CPC Calling Party Control signal on incoming CO calls Assignable for ELCOT GCOT LCOT T1 GCO and T1 LCO cards Reference e 1 3 System Features F G Calling Party Control CPC Signal Detection Parameter TIE Line TIE to CO Security Mode Default No Value Range 1 No 2 Yes Description Function Specifies whether to restrict the TIE to CO call or not If set to Yes the TIE caller must enter a valid TIE User Code before making a CO call via this system Reference 3 1 TIE Line Features F G Programming Guide TIE Line Service 209 Line 210
81. DN BRI port basis Reference None Parameter DN Default Blank Value Range Up to 20 digits consisting of 0 9 x or P Pause Description Function Specifies a DN on an ISDN BRI port basis Reference e 2 2 ISDN Originating Features F G Calling Line Identification Presentation CLIP e 4 3 19 Calling Line Identification Presentation CLIP U M 1 2 10 Card Properties PRI23 Used to assign the parameters for the PRI Prime Rate Interface 23 card When you change the card properties the card status must be OUS Out of Service Card Properties 109 PRI2Z3 Network Type m Line Coding Euro Standard F Bszs x Frame Sequence Extended Superframe ESF Status Message Software information i Disable Version Q361AB020913 Check Sum even DOE1 odd 3273 Status Receive Disconnect Ignore DTMF Signal Duration e0 ms Inter digit Pause fi 12ms Timer Setting OK Cancel Help 34 Programming Guide Configuration Parameter Network Type Default Display only Value Range National ISDN 1 fixed Description Function Displays the ISDN type Reference None Parameter Status Message Default Enable Value Range 1 Enable 2 Disable Description Function Specifies whether to send the Status Message to ISDN or not Reference None Parameter Status Receive Default Disconnect Value Range 1 Disc
82. Description Function Specifies the type of outgoing calls that will be printed out by SMDR 1 None No printout 2 All All calls 3 Toll Only Toll calls only Reference None Parameter Duration Log Incoming Calls Default On Value Range 1 On 2 Off Description Function Specifies whether or not incoming calls will be printed out by SMDR 1 On All calls 2 Off No printout Reference None Programming Guide Maintenance Parameter Print out Caller ID Information Default Number Value Range 1 Number 2 Name 3 Disable Description Function SMDR can print out Caller ID information This setting specifies whether priority is given to Caller ID Name or to Caller ID Number Reference e 1 3 System Features F G Station Message Detail Recording SMDR e 1 5 Attended Features F G Caller ID Service Parameter Print out DID Information Default Disable Value Range 1 Number 2 Name 3 Disable Description Function Activates or deactivates printing out the DID number received from the Central Office Reference e 1 5 Attended Features F G Direct Inward Dialing DID e 2 3 ISDN Attended Features F G Direct Inward Dialing DID Parameter Print out Incoming Call Start RC and Incoming Call Answer AN information Default Disable Value Range 1 Enable 2 Disable Description Function Enables or disables the SMDR printout for RC when an incoming call occurs and AN when an incoming call is ans
83. Fixed Feature Number Type 4 Type 2 43 LCD Time Display Mode 12h C 24h 48 Call Pickup with DSS 5 CO key _ Disable Enable 46 Date Display 47 Tone Type for Outgoing Calls woy x l Busy Reorder x 49 LCD Display Mode while CO talking CallerID Duration l 2 7 System Option 4 x Apply Cancel Help Parameter 31 Answering Call Waiting call by SLT hooking Default Disable Value Range 1 Enable 2 Disable Description Function If enabled an SLT user can answer a call waiting call simply by flashing the switchhook Reference e 1 9 Answering Features F G Call Waiting Parameter 32 Whisper OHCA to extensions other than T74XX Default Disable Value Range 1 Enable 2 Disable Description Function If enabled an extension user can make a Whisper OHCA call to extensions other than KX T7400 series PTs Reference e 1 6 Originating Features F G Programming Guide Off Hook Call Announcement OHCA Whisper e 4 3 50 Off Hook Call Announcement OHCA Whisper U M 139 System 140 Parameter 33 FWD DND lamp pattern Default FWD Flash DND On Value Range 1 FWD Flash DND On 2 FWD On DND Flash Description Function Specifies the lamp patterns of the FWD DND button Reference e 1 8 Ringing Features F G Do Not Disturb DND e 1 11 Transferring Features F G Call Forwarding Paramete
84. Guide 21 1 2 6 Card Properties ELCOT Caller ID Used to set the parameters for the Caller ID card Caller ID Detection r LPR Version 0 MiIiM2M3M4 V5 MEMI VB Detection Start Time r Detection Time Carrier Detection r Header Examination l C Enable Disable Enable C Disable OK Cancel Parameter Caller ID Detection Default Check Value Range 1 Check 2 No check Description Function Activates or deactivates the detection of Caller ID signals transmitted from the Central Office on a port basis Reference 1 5 Attended Features F G Caller ID Service Parameter Detection Start Time Default 240 ms Value Range 80 1200 ms in 80 ms increments Description Function Specifies the time to begin detection of Caller ID signal after bell signal disappeared Reference e 1 5 Attended Features F G Caller ID Service Programming Guide Configuration Parameter Carrier Detection Default Disable Value Range 1 Enable 2 Disable Description Function Activates or deactivates the detection of carrier signal before receiving Caller ID signal Reference e 1 5 Attended Features F G Caller ID Service Parameter Detection Time Default 2000 ms Value Range 1040 4000 ms in 80 ms increments Description Function Specifies the length of time in milliseconds that the system requires to recognize the Caller ID signal sent from the Central Office Refer
85. ID Execute Cancel Help F Sub Jer IV Caller ID Copying the Trunk Line Parameters to Other Trunk Lines 1 Edit the parameters of the copy source Trunk Line and save it 2 Point to _ Copy _ on 4 1 Trunk Line screen of the copy source and click e Trunk Line Copy screen is displayed e The current Trunk Line copy source number is shown as Copy from XXX XXXXX XX 3 Select the Trunk Line parameters to copy in Copy Item field e Only parameters which are available to copy are shown in Copy Item field This depends on the attribute of the copy source Trunk Line Items marked with are copied 4 Point to Select All in the Destination Trunk Line field and click e All displayed Trunk Line Nos will be highlighted e You can also specify one or several Trunk Lines as the copy destination by clicking it them directly 5 Point to Execute and click e Are you sure is displayed 200 Programming Guide Line 6 Point to Xes Y and click e Copying is displayed while the source data is being copied to the destination e Parameters of the destination Trunk Lines are immediately effective when copying is finished Parameter Card No Default Value Range XXX YYY XXX Card No 101 314 YYY Card Type Description Function Specifies the physical number of the trunk card and its type which you are going to prog
86. ISDN before receiving the reply to it Reference None Parameter CO Qsig Master PRI only Qsig Slave PRI only T304 Default 0 s BRD 30 s PRI23 Value Range 0 255 s Description Function Specifies the maximum time allowed between each digit on an outgoing call Applies to the overlap receiving Reference None Parameter CO Qsig Master PRI only Qsig Slave PRI only T305 Default 30s Value Range 4 30 s Description Function Specifies the maximum time that the system waits after sending the DISC disconnection message to ISDN before receiving the reply to it Reference None Programming Guide Configuration Parameter CO Qsig Master PRI only Qsig Slave PRI only T306 Default 30 s BRD 0 s PRI23 Value Range 0 255 s Description Function Reserved for future use Reference None Parameter CO Qsig Master PRI only Qsig Slave PRI only T310 Default 0 s BRD 30 s PRI23 Value Range 10 300 s Description Function Specifies the maximum time that the system waits after receiving the Incoming Call Proceeding call setting acceptance message before receiving the continuance message Reference None Parameter CO Qsig Master PRI only Qsig Slave PRI only T3D3 Default 10 s BRD 30 s PRI23 Value Range 1 120 s Description Function Specifies the time that the system tries to establish L2 in Permanent mode Reference None Parameter CO Qsig Master PRI only Qsig Slave PRI onl
87. Incoming Group e 1 5 Attended Features F G Uniform Call Distribution UCD Parameter UCD Setting Auto LOGOUT Mode Default Value Range Description Function Reference 188 Disable 1 Disable 2 1 10 times Specifies the treatment of extensions ina UCD group who do not cannot answer the call A member extension may be logged out automatically if it does not answer the call for pre determined times 1 10 consecutively If Disable is specified this setting does not function e 1 3 System Features F G Incoming Group e 1 5 Attended Features F G Uniform Call Distribution UCD Programming Guide Group Parameter UCD Setting Supervisor Extension Default Blank Value Range 3 4 digits consisting of 0 9 Description Function Specifies the Supervisor Extension per UCD Group The extension specified as the Supervisor Extension can monitor the number of waiting calls calls placed in the waiting queue and the Login Logout status of UCD Group members through the corresponding DSS buttons Reference e 1 3 System Features F G Incoming Group e 1 5 Attended Features F G Uniform Call Distribution UCD Parameter UCD Setting UCD Call Waiting Default Enable Value Range 1 Disable 2 Enable Description Function This feature is different from regular Call Waiting This feature if enabled allows UCD group members to hear a Call Waiting tone when an inside outside call
88. Line Mode Access Mode Display only Line Mode TEI Display only Line Mode TE Power No check Disable Line Mode SPID DN Timer Setting Software Information Display only 1 2 9 Card Properties BRI SPID DN Program Default SPID Blank 356 Programming Guide Default Values Program Default DN Blank 1 2 10 Card Properties PRI23 Program Default Network Type Display only Status Message Enable Status Receive Disconnect DTMF Signal Duration 80 ms DTMF Signal Inter digit Pause 112 ms Line Coding B8ZS Frame Sequence Extended Superframe ESF Software Information Display only Timer Setting 1 2 11 Card Properties BRI PRI23 ISDN Protocol Timer only T203 Program Default TO1 60 s T02 35s T03 10s T04 10s TOS 60 s T06 35s T07 10s CO Qsig Master PRI only Qsig Slave PRI ls only T200 CO Qsig Master PRI only Qsig Slave PRI 10s CO Qsig Master PRI only Qsig Slave PRI only T302 10 s BRI 15 s PRI23 CO Qsig Master PRI only Qsig Slave PRI only T303 5 s BRI 4 s PRI23 Programming Guide 357 Default Values Program Default CO Qsig Master PRI only Qsig Slave PRI only T304 0 s BRD 30 s PRI23 CO Qsig Master PRI only Qsig Slave PRI only T305 30s CO Qsig Master PRI only Qsig Slave PRI only T306
89. Maintenance 10 7 System Time Used to assign System Time For information on the default values of summer time please refer to the table on the Page 331 10 5 System Time for eae fom e vise Fl EE Disable a E i a 3 m 2 E 2 el a 2 el e a a ea ites lee Disable dddddJJJJJ HILL LIL KATAATAN op of efo ofo ejeje o a o ao a a a al ao a a a ala a a a a SsPspspspispspspsps of of wo ow wo oO oO oO o ananman q A 330 Programming Guide Maintenance Default values of summer time Start End 2001 Apr 01 2001 Oct 28 2002 Apr 07 2002 Oct 27 2003 Apr 06 2003 Oct 26 2004 Apr 04 2004 Oct 31 2005 Apr 03 2005 Oct 30 2006 Apr 02 2006 Oct 29 2007 Apr 01 2007 Oct 28 2008 Apr 06 2008 Oct 26 2009 Apr 05 2009 Oct 25 2010 Apr 04 2010 Oct 31 2011 Apr 03 2011 Oct 30 2012 Apr 01 2012 Oct 28 2013 Apr 07 2013 Oct 27 2014 Apr 06 2014 Oct 26 2015 Apr 05 2015 Oct 25 2016 Apr 03 2016 Oct 30 2017 Apr 02 2017 Oct 29 2018 Apr 01 2018 Oct 28 2019 Apr 07 2019 Oct 27 2020 Apr 05 2020 Oct 25 Programming Guide 331 Maintenance System Time 332 Parameter Year Default 00 Value Range 00 99 Description Function Specifies the last two digits of the year by entering the value directly Reference 1 8 Ringing Features F G Timed Reminder W
90. Manager or Operators Reference e 4 4 2 Background Music BGM External U M Parameter BGM Source Default MUS1 Value Range 1 None 2 MUSI 3 MUS2 Description Function Assigns the External Music Source port to which the External Pager is connected To change music sources you must first select and apply None Then you can select and apply MUS1 or MUS2 Reference e 2 8 2 External Music Source I M Parameter DN Refer Default Value Range Description Function Displays the list of DNs FDNs which are already assigned to the extensions system resources Reference None Programming Guide 243 Line 4 7 ISDN Extension Line Used to assign parameters for ISDN extension lines 4 6 ISDN Extension Line fore a ae C ME E 4 6 ISDN Extension Line ha Parameter Card No Default Value Range XXX BRI XXX Card No 101 314 Description Function Specifies the physical number of the BRI card which you are going to program Reference 1 2 Slot Assignment P G Parameter Port No Default Value Range 1 8 Description Function Specifies the ISDN extension port which you are going to program Reference None 244 Programming Guide Line Parameter Group No Default Display only Value Range 1 128 Description Function Displays the Extension Group to which the selected ISDN extension port is assigned Reference
91. Overwrite Mode 56 56 Call Log Incoming Log Lock 57 57 Timed Reminder Remote TE 58 Login Logout 45 59 Automatic Callback Busy Cancel 46 60 Walking COS 47 61 MODEM Control 791 62 Reserved Reserved for future use Blank 63 70 Quick dial 1 Quick dial 8 Blank 71 Reserved Reserved for future use Blank 72 Remote DND 722 73 Remote FWD Cancel Once 723 74 Trunk Route Control 724 75 UCD Monitor Mode 725 76 TIE Line Access T71 77 92 Other PBX 01 Other PBX 16 Blank 93 Paging Deny Set Cancel 721 94 Trunk Busy out 726 95 Walking Station 727 96 CLIP 711 97 CLIR CNIR 59 98 Reserved Reserved for future use Blank 99 Dial Information CTI Blank 100 COS Primary 792 364 Programming Guide Default Values Program Default 101 COS Secondary 793 102 Reserved Reserved for future use Blank 103 Group Login Logout 48 104 Group FWD 714 105 120 Reserved Reserved for future use Blank 2 4 Class of Service COS 2 4 1 Class of Service COS 1 2 Program Default COS No 1 Trunk Group Setting TRS Level Day Night 1 Account Code Mode Optional Switching Day Night Mode Disable Call from TRS Level 7 Extension Enable Time Limit of Outside Calls No Transfer to CO Disable Call FWD to CO TIE Disable Off Hook Call Announcement OHCA Enable Call FWD Follow Me Enable Busy Override Disable DND Override Disable Busy Overri
92. Parameter Break Default 60 Value Range 1 60 2 67 Description Function Specifies the break for pulse digits This is the ratio between on hook and off hook signals during digit transmission Reference None Parameter Flash Time Default 608 ms Value Range 16 4080 ms in 16 ms increments Description Function Specifies the length of Flash signal which the system sends to the local Central Office Notes e This assignment is helpful when you need finer resolution in the flash time than the choices presented in Flash Time in 3 1 Trunk Group screen To activate this assignment set Flash Time in 3 1 Trunk Group screen to 80 ms e This assignment is necessary when your Central Office requires a Flash Time not listed in Flash Time in 3 1 Trunk Group screen Reference 3 2 Trunk Group P G Programming Guide 19 Configuration 20 Parameter Pulse Feedback Tone Default Yes Value Range 1 Yes 2 No Description Function On outgoing CO calls the dialed number is toned out which informs the extension user that dialed number has been dialed out The dialed number is toned out by default Select No to turn off the pulse feedback tone Reference None Parameter Caller ID Default Value Range Description Function You can enter into Caller ID screen Section 1 2 6 Card Properties ELCOT Caller ID by clicking Caller ID on this screen Reference None Param
93. R Reference e 1 3 System Features F G Station Message Detail Recording SMDR e 1 8 Ringing Features F G Log In Log Out Programming Guide Maintenance Parameter Time Display Mode Default 12h Value Range 1 12h 2 24h Description Function Specifies the time display mode 12 hour or 24 hour notation which will be printed out by SMDR Reference e 1 3 System Features F G 10 4 2 SMDR 2 2 Station Message Detail Recording SMDR Station Message Detail Recording SMDR automatically records detailed information for outside calls Parameter Print out supplementary digits ISDN only Default Disable Value Range 1 Enable 2 Disable Description Function Includes the SMDR printout of outgoing supplementary digits This is only available on ISDN calls Reference e 1 3 System Features F G Programming Guide Station Message Detail Recording SMDR 319 Maintenance 10 5 Power Failure Transfer 320 Power Failure Transfer connects specific telephones any SLT and a certain type of APT to pre determined CO lines in the event of system power failure 10 3 Power Failure Transfer m Trunk Card 1 a 2 None 3 None 4 None H s None B None T None R g None g None 1ofNone None E 12 None F m Extension Card 1 None 13 None 2 None 14 None Ff 3 None 18 None Ff 4 None 16 None Ff s None 17 None efons tefo H T None
94. Reference None Programming Guide 45 Configuration 46 Parameter Tone OFF Time Min Default 144 0 ms Value Range 57 6 3600 ms in 14 4 ms increments Description Function Specifies the minimum time in milliseconds that the CYCLIC tone from the Central Office is not detected When the system detects no tone within the time range it is recognized as Tone OFF Note e This parameter is valid when Option is selected in the CYCLIC Detection Mode menu Reference None Parameter Tone OFF Time Max Default 244 8 ms Value Range 57 6 3600 ms in 14 4 ms increments Description Function Specifies the maximum time in milliseconds that the CYCLIC tone from the Central Office is not detected When the system detects no tone within the time range it is recognized as Tone OFF Note e This parameter is valid when Option is selected in the CYCLIC Detection Mode menu Reference None Parameter LPR Version Default Display only Value Range 0 15 Description Function Displays the LPR Software Version Reference None Programming Guide Configuration 1 2 13 1 2 14 Card Properties ERMT Used to set the parameters for the ERMT card Gard Properties 112 ERMT Baud Rate Ea M OK Cancel Help Parameter Baud Rate Modem Speed Default 33600 bps 1200 bps 9600 bps 14400 bps 19200 bps 28800 bps 33600 bps Value Range na WN nN De
95. Reference e 4 3 24 CTI Computer Telephony Integration Code Entry Programming Guide System Parameter 100 COS Primary Default 792 Value Range 1 4 digits consisting of 0 9 or Description Function Specifies the feature number for setting the COS Primary Reference e 4 4 10 Switching COS U M Parameter 101 COS Secondary Default 793 Value Range 1 4 digits consisting of 0 9 x or Description Function Specifies the feature number for setting the COS Secondary Reference e 4 4 10 Switching COS U M Parameter 102 Reserved Reserved for future use Default Blank Value Range Description Function Reference Parameter 103 Group Login Logout Default 48 Value Range 1 4 digits consisting of 0 9 x or Description Function Specifies the feature number for Group Log in Log out to from the members of an Incoming Group Reference e 4 3 45 Log In Log Out U M Parameter 104 Group FWD Default 714 Value Range 1 4 digits consisting of 0 9 X or Description Function Specifies the feature number for setting canceling the Call Forwarding feature from one Incoming Group to another Incoming Group or Extension Group Reference e 1 11 Transferring Features F G Programming Guide Call Forwarding All Calls to an Incoming Group e 4 3 9 Call Forwarding U M 101 System Parameter 105 120 Reserved Reserved for future use Default Blank Value Range Descriptio
96. Reference e 4 3 9 Call Forwarding U M Parameter Off Hook Call Announcement OHCA Default Enable Value Range 1 Enable 2 Disable Description Function Specifies whether to utilize OHCA Whisper OHCA feature or not Note e This setting is valid at the following PT extensions OHCA When the called extension is using the KX T7130 KX T7235 or KX T7436 Whisper OHCA When both calling and called extensions are using one of the KX T7400 series PTs Reference e 1 6 Originating Features F G Off Hook Call Announcement OHCA Off Hook Call Announcement OHCA Whisper e 4 3 49 Off Hook Call Announcement OHCA U M e 4 3 50 Off Hook Call Announcement OHCA Whisper U M Programming Guide System Parameter Call FWD Follow Me Default Enable Value Range 1 Enable 2 Disable Description Function Enables or disables Call Forwarding Follow Me feature Reference e 4 3 9 Call Forwarding U M Parameter Busy Override Default Disable Value Range 1 Enable 2 Disable Description Function Enables or disables Executive Busy Override feature Reference e 4 3 33 Executive Busy Override U M Parameter DND Override Default Disable Value Range 1 Enable 2 Disable Description Function Enables or disables DND Override feature Reference e 4 3 28 Do Not Disturb DND Override U M Parameter Busy Override Deny Default Enable Value Range 1 Enable 2 Disable Description Function Enables or disabl
97. S DPT Port Assignment Used to assign parameters for VPS DPT ports Up to eight Panasonic Voice Processing Systems VPSs can be connected to the system 1 4 VPS DPT Port Assignment TVS No i VPS Card None Type None DN Refer z Q 3 a JackNo Port No TIED TTT 1 4 YPS DPT Port Assignment hd OK Any Cancel Help How to set up a TVS 1 Assignment of the card which will be connected to the VPS System e When you use a new DLC DHLC card and set up the TVS to the PBX Assign the card type of the slot to be installed to DLC or DHLC card and change the card status to INS In Service in 1 1 Slot Assignment screen Then see the information of Card Properties and confirm that the software version of the card shows more than 1 e When you connect the TVS to the existing DLC DHLC Go to step 2 2 Assignment of the port which will be connected to the VPS System Change the attribute of the port to be connected to the TVS to VPS DPT in 1 3 Extension Port Assignment screen When the attribute of the port is changed to VPS DPT the parameters except Attribute will disappear and the directory number will be purged 3 Assignment of VPS card and its model Select the corresponding equipment number in TVS No menu the card DLC DHLC which connects with the TVS in VPS Card menu and the model of TVS in Type menu in 1 4 VPS DP
98. S Consoles at a time You can also specify one or several DSS Consoles as the copy destination DSS Console Copy Copyfrom 109DLC 01 m Destination DSS Console Card Port r Copy Item PF Key Select All Execute Cancel Help Copying the DSS Console Parameters to Other DSS Consoles 1 Edit the parameters of the copy source DSS Console and save it 2 Point to Copy on 4 3 DSS Console screen of the copy source and click e DSS Console Copy screen is displayed e The current DSS Console copy source number is shown as Copy from XXX XXXXX XX 3 Select the DSS Console parameters to copy in Copy Item field Items marked with are copied 4 Point to Select All in the Destination DSS Console field and click e All displayed DSS Console Nos will be highlighted e You can also specify one or several DSS Consoles as the copy destination by clicking it them directly 5 Point to Execute and click e Are you sure is displayed 6 Point to Xes CY and click e Copying is displayed while the source data is being copied to the destination e Parameters of the destination DSS Consoles are immediately effective when copying is finished 232 Programming Guide Line Notes e Flexible DSS PF Key Assignment should be done before executing this copy function e Copy function is not available in the Interactive mo
99. Service Code is transmitted to the VM port and the VM service does not work Reference e 1 3 System Features F G Integration VPS Parameter Extension s mailbox number Default Programmed number Value Range 1 Extension number 2 Programmed number Description Function Specifies whether an extension s mailbox number is substituted by the extension number or it is programmable free If a call is forwarded or rerouted to the Voice Mail port the system automatically transmits the mailbox number to the Voice Mail port to specify the extension user s mailbox To make it programmable select Programmed number then assign the mailbox number by Mailbox No setting in Section 4 3 Extension Line Reference e 1 3 System Features F G Integration VPS Parameter Call from AA port to AA port Default Allow Value Range 1 Allow 2 Deny Description Function Allows or disallows calling from an AA port of Voice Mail port to another AA port Reference e 1 3 System Features F G Programming Guide Integration VPS 271 Features 272 Parameter Sending out Follow on ID after FWD Default Enable Value Range 1 Disable 2 Enable Description Function Specifies whether or not the system sends Follow on ID to a Voice Mail port after forwarding a call to the Voice Mail port Reference e 1 3 System Features F G Integration VPS Parameter Sending out Follow on ID after IRNA Default Disable Value Ran
100. System Programming mode by entering this password Password System Programming Protection Level 2 Password System Programming Protection Level 3 Password System Programming Protection Level 4 322 Programming Guide Maintenance Warning to the Dealer regarding the System Password a Please thoroughly inform the importance of the password and the dangers involved to the customer b Please maintain the secrecy of the password Because a person who knows the password can easily take over the control of any PBX system in the market and he may proceed to commit toll fraud c Please change the password periodically d We strongly recommend that you set the system password to 7 digits for maximum protection against hackers e You have to take the following measures to find the system password when you forget the password Therefore please never forget the password e Ifyou have the backup system data you can find the password by loading the backup system data to your PC and check the Password with programming screen e Ifyou don t have the backup system data you have to program again or contact your Panasonic dealers The higher the password level level 1 is the highest is the more programming items the administrator can access as shown in the table below Programming Level 1 Level 2 Level 3 Level 4 1 Configuration Vv V 2 System 3 Group 4 Line 5 Features SB NSS
101. T extension line on a BRI port basis Note e When you change the programming data the status of the card must be made OUS Out of Service and then INS In Service Reference e 2 1 ISDN Features F G Integrated Services Digital Network ISDN Integrated Services Digital Network ISDN Extension 4 7 ISDN Extension Line P G Parameter DN Default Blank Value Range 3 4 digits consisting of 0 9 or X Description Function Specifies the DN Directory Number for the BRI port Assignable only when EXT is specified in Type assignment Note e X can be used as a wild card character which substitutes any digit in its position The last one or two digits of DN may be X Reference 2 3 Numbering Plan P G Programming Guide Configuration Parameter Group No Default 1 Value Range 1 48 or 1 128 Description Function Type CO Specifies the Trunk Group 1 48 to which the BRI port is assigned Type EXT Specifies the Extension Group 1 128 to which the BRI port is assigned Reference e 1 3 System Features F G Extension Group Trunk Group 3 2 Trunk Group P G 3 3 Extension Group P G Parameter Status Default Value Range 1 INS 2 OUS 3 FAULT Description Function Specifies the operating status of the BRI port 1 INS The BRI port is In Service 2 OUS The BRI port is Out of Service 3 FAULT The BRI port is defective hardware In this case the LED indicator on the BRI
102. T Port Assignment screen Programming Guide 59 Configuration 4 Assignment of the extension port connected to the TVS Select in Port No menu the extension port number of the card DLC DHLC to which the TVS DPT jack is to be connected This menu is displayed only when the attribute of the port is assigned to VPS DPT at step 2 After Port No selection assign DN and Extension Group No for the port Save the data changes by clicking Apply Then set Port Status to INS In Service Jack No 1 must be assigned because the port is used as the channel to control the VPS 5 Synchronization of the communication between the KX TD500 System and the TVS The KX TD500 System begins synchronization with the VPS when the step 4 is done The Power LED of the VPS begins flashing at the same time The LED will turn on after the synchronization is completed It takes for about 30 seconds to 1 minute to be able to use the VPS system It depends on the VPS model and the port number you set up Parameter TVS No Default 1 Value Range 1 8 Description Function Specifies one of the Panasonic Voice Processing Systems VPSs connected to the KX TD500 system which you are going to program Reference e 1 3 System Features F G Integration VPS 1 2 Slot Assignment P G Parameter VPS Card Default None Value Range None XXX YYY XXX Card No 101 314 YYY Card Type Description
103. Table Used to modify the user dialed number so that it matches the requirements of the carrier Up to 48 Digits Modification entries can be programmed in the system 7 4 ARS Digits Modification Table 7 4 Digits Modification Table ha oa MM O FF oa oi b MES O O o ME FF Parameter Entry No Default 01 08 Value Range 01 48 in 8 entries increments Description Function Specifies the entry number of Digits Modification table which you are going to program Reference e 1 6 Originating Features F G Automatic Route Selection ARS Parameter Digits to delete Default 0 Value Range 0 9 Description Function Specifies the number of digits to be deleted from the beginning of the user dialed number If you set to 0 no digit is deleted from the user dialed number Reference e 1 6 Originating Features F G 294 Automatic Route Selection ARS Programming Guide ARS Automatic Route Selection Parameter Number to be added Default Blank Value Range Up to 20 digits consisting of 0 9 x or P Pause Description Function Specifies the dialing number to be added to the beginning of the user dialed number Reference e 1 6 Originating Features F G Programming Guide Automatic Route Selection ARS 295 ARS Automatic Route Selection 296 Programming Guide Private Network Section 8 Private N
104. able No is assigned and the Route Plan Table No also must be deleted when the leading dial is deleted E5022 File format error Line X Format syntax error was found at the indicated line X in the database file E6001 Too long TRS Deny or Exception dial TRS Deny or Exception dial can be registered up to 10 digits consisting of 0 9 or X a wild card E6002 Cannot assign more than 400 TRS deny codes There is a limit of 400 toll restriction deny codes per system E6003 Cannot assign more than 200 TRS exception codes There is a limit of 200 toll restriction exception codes per system E7001 Invalid arrangement of time zones Each successive ARS time zone must be later in time Namely this pattern must be followed Time A lt Time B lt Time C lt Time D E7002 Assign both trunk group number and modification table number Cannot assign just trunk group number or just modification table number Both must be assigned as a pair under ARS routing plan E9001 Invalid directory number for DID destination There are seven possible destinations for DID calls 1 An extension 2 an external pager TAFAS 3 an OGM group 4 a remote extension 5 an extension group 6 an incoming group or 7 a phantom extension E9002 Page length must be 4 lines more than Skip Perforation The difference of Page Length and Skip Perforation must be more than 4 lines E9003 Trunk or extension card dupli
105. ages WXXXX Message Code Description wo0001 Save system data Some parameters on the screen were changed A click on OK or a screen switch was attempted without saving data Ww0002 The status of the port is In Service INS Would you like to continue When the status of a port is In Service INS and you change some parameters screens of 1 Configuration the port is reset A call in progress will be dropped W0003 Save system data before Copy Modified parameters without saving are not effective for Copy feature w0005 Save data file Tried to close exit or open another file without saving data in the Batch mode although parameters were changed W0006 Mismatch between PC software version and PBX software version Proceed to load matching PC software PC software Maintenance Console software is not compatible with the current KX TD500 software Load the appropriate PC software into your PC Then connect your PC to the KX TD500 again W1001 Change the card XXX YYY status Please confirm whether or not to execute OUS Out of Service INS In Service command to the card XXX YYY XXX Slot No YYY Card Type The OUS Out of Service INS In Service command to the card is effective to the whole ports of the card W1002 Change the status of port XXXXX Please confirm whether or not to execute OUS Out of Service INS In Service command to the port XXXXX XXXXX port physical numb
106. ake Up Call Timed Reminder Remote Wake Up Call 1 17 Display Features F G Display Date and Time 3 2 1 000 Date and Time Set U M Parameter Month Default Jan Value Range Jan Dec Description Function Selects the month by clicking the small triangle Reference 1 8 Ringing Features F G Timed Reminder Wake Up Call Timed Reminder Remote Wake Up Call 1 17 Display Features F G Display Date and Time 3 2 1 000 Date and Time Set U M Parameter Day Default 01 Value Range 01 31 Description Function Specifies the date in two digits by entering the value directly Reference 1 8 Ringing Features F G Timed Reminder Wake Up Call Timed Reminder Remote Wake Up Call 1 17 Display Features F G Display Date and Time 3 2 1 000 Date and Time Set U M Programming Guide Maintenance Parameter Day of the week Default Sat Value Range Sun Sat Description Function Selects the day of the week by clicking the small triangle Reference 1 8 Ringing Features F G Timed Reminder Wake Up Call Timed Reminder Remote Wake Up Call 1 17 Display Features F G Display Date and Time 3 2 1 000 Date and Time Set U M Parameter Hour Default 12 Value Range 0 1 12 Description Function Specifies the hour in two digits by entering the value directly Reference 1 8 Ringing Features F G Timed Reminder Wake Up Call Timed Reminder Remote Wake Up
107. alue Range Description Function Reference All Blank 4 10 digits consisting of 0 9 Specifies the User Codes for DISA TIE feature Warning for the Direct Inward System Access Users When you enable the CO to CO Line Call feature of Direct Inward System Access DISA function if a third party discovers the password a DISA User Code of the system you have a risk that they will make illegal phone calls using your telephone line and the cost may be charged to your account In order to avoid this problem we strongly recommend the following points 1 Carefully maintain the secrecy of the password 2 Specify a complicated password as long and random as you can make it 3 Change the password frequently Notes e DISA user code is required when the DISA caller attempts to make an outside call Trunk Security mode or to make either extension or outside call All Security mode e If TIE to CO Security Mode in Section 4 2 Trunk Line is set to Yes entering TIE user code is required when the TIE caller attempts to make a CO call e Ifthe entire code for example 1234 is included in another code for example 12345 it is not valid e 1 5 Attended Features F G Direct Inward System Access DISA e 3 1 TIE Line Features F G TIE Line Service e 4 3 26 Direct Inward System Access DISA U M Parameter COs Default Value Range Description Function Reference Programming Guide All 96 1
108. alue Range 1 Check Enable 2 No check Disable Description Function Specifies whether to utilize ARS Automatic Route Selection or not If set to No No check Trunk Access Idle is activated instead of ARS when an extension user dials 9 for making an outside call Reference e 1 6 Originating Features F G Automatic Route Selection ARS 7 1 ARS Automatic Route Selection P G Parameter External Paging Tone Default Check Value Range 1 Check Enable 2 No check Disable Description Function If checked a confirmation tone is emitted from external pagers before voice announcement Reference e 1 14 Paging Features F G Paging e 4 3 55 Paging U M Programming Guide System Parameter System Speed Dial TRS Level Override Default No check Value Range 1 Check Enable 2 No check Disable Description Function Enables or disables Toll Restriction Override for System Speed Dial Numbers feature If enabled Check all extension users in the tenant can make System Speed Dialing calls without toll restriction Reference e 1 6 Originating Features F G Toll Restriction Override for System Speed Dialing Parameter Confirmation Tone for Station or External Paging Default Check Value Range 1 Check Enable 2 No check Disable Description Function If checked a confirmation tone is sent to the extension user who initiated the Station Paging or the External Paging Reference e 1 14 Pa
109. ame and number for Caller ID Cannot assign just the name for Caller ID E5002 Cannot use more than seven characters There can be a maximum of seven characters in an absent message E5003 User code format error Please assign the DISA TIE user code of 4 10 digits consisting of 0 9 E5004 User code duplicated Each code in the DISA TIE User Code must have a unique number E5005 Cannot set RET command at the head Please set the command except for RET at the head of UCD Time Table E5006 Cannot assign more than 1000 account codes There is a limit of 1000 account codes per system E5007 You have exceeded the tenant limit of Speed Dialing numbers The maximum number of Speeding Dialing numbers per tenant is specified in 2 1 Tenant screen E5008 You have exceeded the limit of Caller ID codes There is a limit of 1000 Caller ID codes per tenant and 2000 Caller ID codes per system E5009 Invalid User code If the entire code for ex 1234 is included in another code for ex 12345 it is not valid 346 Programming Guide Programming Error Messages Error Message Error Code Description E5010 Specify the code The account code also must be entered when the TRS Level is assigned and the TRS Level also must be deleted when the account code is deleted E5011 Specify the leading digits The ARS leading dial also must be entered when the Route Plan T
110. arrives but all the extensions in the UCD Group are busy Notes e To use this feature this setting must be set to enable e In addition each extension must enable regular Call Waiting Reference e 1 3 System Features F G Programming Guide Incoming Group e 1 5 Attended Features F G Uniform Call Distribution UCD 189 Group Parameter Operator Setting Call Priority Default CO Call 1 Intercept Routing 2 Recall 3 Extension Call 4 Value Range Priority 1 4 Description Function Specifies the answering priority of incoming calls to the Operator Group by a type of call when more than one call is ringing at an Operator extension Assignable only when Operator is specified in Group Type programming Notes e If all extensions in the Operator group are busy incoming calls directed to the group will be put in the waiting queue in order of precedence determined by this Call Priority setting e Ifthe same priority is set on all four types of calls the calls will be put in the waiting queue in order of the arrival Reference e 1 3 System Features F G Operator Group e 1 6 Originating Features F G Operator Call Parameter Operator Setting Ringing Type Default Single Value Range 1 Multi 2 Single Description Function Specifies whether the calls coming in on an Operator Group ring one Operator Single or all Operators in the group Multi simultaneously Assignable only when Operator
111. ault DISA Value Range 1 DISA 2 UCD OGM 3 Wake up Description Function Specifies the usage of OGM resources on DISA cards 1 DISA OGM for DISA feature 2 UCD OGM OGM for UCD group 3 Wake up OGM for Wake up message Reference e 1 5 Attended Features F G Direct Inward System Access DISA Programming Guide Group Parameter Security Mode Default Trunk Value Range 1 None 2 Trunk 3 All Description Function Specifies the Security Mode for DISA callers Assignable only when DISA is specified in OGM Type programming 1 None Non security mode DISA callers can make both outside and intercom calls via DISA without restriction 2 Trunk Trunk Security mode DISA callers are required to enter a pre assigned DISA user code to make outside calls via DISA 3 All All Security mode DISA callers are required to enter a pre assigned DISA user code to make both outside and intercom calls via DISA Reference e 1 5 Attended Features F G Direct Inward System Access DISA Parameter DISA built in Automated Attendant Tables Dial 0 Dial 9 Default Blank Value Range 3 4 digits consisting of 0 9 Description Function Specifies the extension numbers to each DISA built in Auto Attendant number Both DN of extensions and FDN Floating Directory Number of extension groups phantom extensions or TAFAS can be specified Assignable only when DISA is specified in OGM Type programming Note e A DISA
112. basis Please refer to TIE Line Network Alternate Routing of Section 3 1 TIE Line Features in the Features Guide for further information 2 6 Trunk to Trunk Restriction zs trnktoTrnkresicnon S OK aew canes He Parameter Source Trunk Group No Default 1 Value Range 1 48 Description Function Specifies the source trunk group 1 48 the first point of trunk to trunk relay which you are going to program Reference 3 1 TIE Line Features F G TIE Line Service Parameter Destination Trunk Group No 1 48 Default No check Value Range 1 No check Restricted 2 Check Not restricted Description Function Specifies the destination trunk group 1 48 the second point of trunk to trunk relay which you allow to accept a trunk call from the source trunk group Reference e 3 1 TIE Line Features F G TIE Line Service 124 Programming Guide System 2 8 System Option 2 8 1 System Option 1 Used to assign system option parameters No 1 No 10 Parameter 1 Sound source during transfer Default Music on Hold Value Range 1 Ringback Tone 2 Music on Hold Description Function Used to determine whether the system sends Music on Hold or Ringback Tone to the party being transferred Ringback Tone is available when Music on Hold is not provided by the system Reference e 1 11 Transferring Features F G Programming
113. ber of the Voice Mail extension 2WAY REC IDN Specifies the Directory Number of the Voice Mail extension 2WAY TRN IDN Specifies the Directory Number of the Voice Mail extension Programming Guide 235 Line Parameter Key Type Default Not Stored Value Range Please refer to Description Function Description Function Not Stored Key Type is not assigned SINGLE CO Single CO button GROUP CO Group CO button DSS Direct Station Selection button ONE TOUCH One Touch Dialing button MESSAGE Message Waiting button MESSAGE OTHER Another Extension Phantom Extension Message Waiting button FWD DND Call Forwarding Do Not Disturb button G FWD Group Call Forwarding button SAVE Saved Number Redial button ACCOUNT Account Code entry button CONF Conference button VTR Voice Mail Transfer button 2WAY REC Two way Recording button 2WAY TRN Two way Transfer button LCS Live Call Screening button LCS CANCEL Live Call Screening Cancel button DAY NIGHT Day Night switching button ANSWER Answer button RELEASE Release button TONE THROUGH Tone Through button Reference e 2 2 3 Flexible Button Assignment U M e 5 2 1 Station Programming U M 236 Programming Guide Line 4 4 2 Flexible PF Key Assignment for DSS Console Used to determine the usage of flexible PF buttons on DSS Consoles The following screen is displayed by clicking PF Key on 4 3 DSS Console screen I Flex ible PF Key Others
114. bering Plan ID applied to the incoming CO calls via ISDN Public Switched Telephone Network Reference None Parameter Numbering Plan ID Incoming Private Default Private Value Range 1 Default 2 Unknown 3 ISDN Telephony 4 National Standard 5 Private Description Function Specifies the Numbering Plan ID applied to the incoming CO calls via ISDN Private Network Reference None 160 Programming Guide Group Parameter PBX Dial Tone Default Disable Value Range 1 Enable 2 Disable Description Function If enabled the system sends a dial tone to the extension user who seizes a T1 digital trunk line Available for T1 digital trunk lines only Note e Incase of the T1 digital trunk line the Central Office does not send a dial tone to the caller Reference e 1 3 System Features F G T1 Carrier Parameter PBX Ringback Tone Default Disable Value Range 1 Enable 2 Disable Description Function Specifies whether or not the system sends a ringback tone to the extension user who seizes a T1 digital trunk line Available for T1 digital trunk lines only Note e Incase of the T1 digital trunk line the Central Office does not send a ringback tone to the caller Reference e 1 3 System Features F G T1 Carrier Parameter Type of Number Outgoing Public Default Default Value Range 1 Default 2 Unknown 3 International 4 National 5 Network Specific 6 Subscriber Description Function Specifies
115. caller can call those extensions simply by dialing a one digit DISA built in Auto Attendant number corresponding to the extension Reference e 1 5 Attended Features F G Programming Guide Direct Inward System Access DISA 195 Group 196 Programming Guide Line Section 4 Line Programming Guide 197 Line 4 1 Line Used to assign various parameters for both trunk and extension lines E TD500 Maintenance 198 Programming Guide Line 4 2 Trunk Line Used to assign various parameters for trunk lines pmo Ie le Wigitel DOME Dio Programming Guide 199 Line Trunk Line Copy Used to copy a part of or all settings of a certain Trunk Line to all other same type Trunk Lines at a time You can also specify one or several Trunk Lines as the copy destination This copy function is available between the Trunk Lines of the same type Trunk Cards Trunk Line Copy Copy from 108 ELCOT 01 r Copy It E noe Destination Trunk Line ue Card Port 108 ELCOT 02 108 ELCOT 03 108 ELCOT 04 108 ELCOT 05 108 ELCOT 06 108 ELCOT 07 108 ELCOT 08 V Destination Day M Destination Night Destination Lunch IV Destination Break Start Siotal iwpe IV CPC Signal OUT IN fm Diotto receive DID Eyi onalmimeout E DID IME Digits te delete fT DID IME Mimberts fe added Select All IV TIE Line TIE to CO Security Mode TIE Line Sending TIE Caller
116. can also specify one or several Trunk Groups as the copy destination by clicking it them directly 5 Point to Execute and click e Are you sure is displayed 6 Point to Yes Y and click e Copying is displayed while the source data is being copied to the destination e Parameters of the destination Trunk Groups are immediately effective when copying is finished 154 Programming Guide Group Parameter Group No Default 1 Value Range 1 48 Description Function Specifies the trunk group 1 48 which you are going to program Reference 1 3 System Features F G Trunk Group Parameter Copy Default Value Range Description Function You can enter into Trunk Group Copy screen by clicking this button Reference Parameter Intercept Destination Day Night Default Blank Value Range 3 4 digits consisting of 0 9 Description Function Specifies the destination extension 3 or 4 digits for Intercept Routing feature in both Day and Night modes respectively Notes e Intercept Routing provides an automatic re direction of calls that have not been answered e These are seven possible destinations of intercepted call 1 An extension 2 an external pager TAFAS 3 an OGM group 4 an extension group 5 an incoming group 6 a phantom extensionor or 7 an ISDN extension except the wild card character X Reference e 1 11 Transferring Features F G Programming Guide
117. card will light Reference None Parameter DN Refer Default Value Range Description Function Displays the list of DNs FDNs which are already assigned to the extensions system resources Reference None Programming Guide 71 Configuration 1 9 PRI Port Assignment Used to assign the parameters for PRI Prime Rate Interface ports 1 9 PRI Port Assignment 5 a a a E a a a a 1 9 PRI Port Assignment ha Parameter Card No Default Value Range XXX PRI23 XXX Card No 101 314 Description Function Specifies the physical number of the PRI23 card which you are going to program Reference 1 2 Slot Assignment P G 72 Programming Guide Configuration Parameter Type Default Value Range Description Function Reference CO 1 CO 2 EXT 3 Qsig Master 4 Qsig Slave Specifies the type of each PRI port on a PRI port basis Notes e When you change the programming data the status of the card must be made OUS Out of Service and then INS In Service e The type of PRI port can be assigned per PRI23 card e This setting is valid when the LPR software version of the PRI23 card is Q361AB or later e When you change the type of PRI port the Group No is assigned to 1 First assign the type and then Group No e 2 1 ISDN Features F G Integrated Services Digital Network ISDN Integrated Ser
118. cated Under Power Failure Transfer a trunk card or an extension card can be specified only once E9004 Assign both trunk card and extension card Cannot assign just trunk card or just extension card Both must be assigned as a pair under Power Failure Transfer E9005 Time or date format error The invalid value of time or date is entered E9006 Invalid System Programming password Please assign the 4 through 7 digit System Programming password of alphanumeric characters Programming Guide 347 Programming Error Messages Error Message Error Code Description E9007 Invalid User Programming password Please assign the 4 through 7 digit User Programming password consisting of 0 9 E9008 Invalid Walking COS password Please assign the 4 through 7 digit Walking COS password consisting of 0 9 E9009 DID MDN number duplicated Each DID MDN number in 9 1 DID Dial Registration screen must have a unique number E9010 Number of DID dial must be equal to or less than 16 digits The total digits of Base Number and Number of Digits are over 16 E9011 Beginning Entry No must be equal to or less than 991 Cannot specify the number 992 999 as the Beginning Entry No because Number of Registrations is set by 10 entries increments and the number of available entries are limited to 1000 348 Programming Guide Programming Error Messages 11 2 Warning Mess
119. ce Auto Start Time Specifies Start End time of DAY NIGHT LUNCH BREAK service on a day of the week basis This setting is valid when Auto mode is selected in DAY NIGHT Switching Mode setting Up to six time frames Day Night Lunch Start Lunch End Break Start Break End can be set up on each day of the week Parameter Day SUN SAT Default 9 00 AM Value Range 1 Disable 2 12 00 11 59 PM AM Description Function Specifies the start time for Day Service Reference e 1 3 System Features F G Night Service Parameter Night SUN SAT Default 5 00 PM Value Range Same as Day Description Function Specifies the start time for Night Service Reference e 1 3 System Features F G Programming Guide Night Service 79 System 80 Parameter Lunch Start SUN SAT Default 12 00 PM Value Range Same as Day Description Function Specifies the start time for Lunch Service Reference e 1 3 System Features F G Night Service Parameter Lunch End SUN SAT Default 1 00 PM Value Range Same as Day Description Function Specifies the end time for Lunch Service Reference e 1 3 System Features F G Night Service Parameter Break Start SUN SAT Default 3 00 PM Value Range Same as Day Description Function Specifies the start time for Break Service Reference e 1 3 System Features F G Night Service Parameter Break End SUN SAT Default 3 30 PM Value Ra
120. characters are saved and the rest are deleted W4006 DID TIE additional dial must not exceed 8 digits Truncate it Truncate means that the leading 8 digits are saved and the rest are deleted W4007 Mailbox number must not exceed 16 digits Truncate it Truncate means that the leading 16 digits are saved and the rest are deleted A digit can be 0 through 9 or P pause W4008 Subscriber number must not exceed 16 digits Truncate it Truncate means that the leading 16 digits are saved and the rest are deleted Ww5001 System Speed Dialing name must not exceed 10 characters Truncate it Truncate means that the leading 10 characters are saved and the rest are deleted Ww5002 System Speed Dialing number must not exceed 24 digits Truncate it Truncate means that the leading 24 digits are saved and the rest are deleted W5003 Emergency dial number must not exceed 24 digits Truncate it Truncate means that the leading 24 digits are saved and the rest are deleted W5004 Quick Dial number must not exceed 24 digits Truncate it Truncate means that the leading 24 digits are saved and the rest are deleted W5005 Account Code must not exceed 10 digits Truncate it Truncate means that the leading 10 digits are saved and the rest are deleted W5006 Special Carrier Code must not exceed 10 digits Truncate it Truncate means that the leading 10 digits are saved and the rest are deleted W5008 Absent message mus
121. creen is displayed by clicking Key Type Display button including Not Stored for each CO key on the above screen Flexible CO Key LOOP CO e DOEANE wiil EAE 2 canei iem lt Additional Parameters Required by Key Type gt Depending on a Key Type additional parameters are required as follows 224 Programming Guide Line Additional Key Type Parameters Description default SINGLE CO_ Trunk Line Specifies the trunk port physical number 10101 to 31416 No Tone 2 Specifies the ringer frequency ring tone type 1 8 for incoming calls GROUP CO_ Trunk Group Specifies the Trunk Group number 01 48 No Tone 2 Specifies the ringer frequency ring tone type 1 8 for incoming calls LOOP CO Tone 2 Specifies the ringer frequency ring tone type 1 8 for incoming calls DSS EXT Specifies the extension number 3 or 4 digits PHANTOM EXT Specifies the phantom extension number 3 or 4 digits Ringing Yes Specifies whether the extension rings or not when a call to a phantom button comes in on the extension PDN Tone 2 Specifies the ringer frequency ring tone type 1 8 for incoming calls Ringing Type Specifies the timing of ringing when a call comes in on the Immediate extension Immediate 1 ring Delay 3 ring Delay 6 ring Delay No Ring SDN EXT Specifies the PDN owner s extension number 3 or 4 di
122. ction 1 2 Slot Assignment 2 Wink The system sends the dialing digits to CO after receiving the wink signal e 3 1 TIE Line Features F G TIE Line Service e 1 5 Attended Features F G Direct Inward Dialing DID 207 Line 208 Parameter Answer Wait Timer Default None Value Range 1 None 2 1 min 3 2 min 4 3 min 5 4 min Description Function Specifies the length of time in minutes the system waits after an outgoing CO call is made before the other party answers the call If the call is not answered before this timer expires the call will be disconnected automatically Assignable only when T1 TIE DID BRI PRI23 card is installed in the system Reference None Parameter CPC Signal OUT Detection Default Enable DID card Disable ELCOT GCOT LCOT T1 GCO T1 LCO card Value Range 1 Enable 2 Disable Description Function Specifies whether CPC Detection on outgoing CO calls is enabled or disabled If enabled the system disconnects the line with the time set in program CPC Signal OUT Detection Detection Time when the CPC signal is detected Reference e 1 3 System Features F G Calling Party Control CPC Signal Detection Parameter CPC Signal OUT Detection Detection Time Default 400 ms Value Range 1 None 2 6 5 ms 3 2 75 x 8 ms Description Function Specifies the expected minimum duration for detecting CPC Calling Party Control signal on outgoing
123. d when your PBX is a part of a TIE Line Network Reference e 3 1 TIE Line Features F G Programming Guide TIE Line Service 299 Private Network 300 Parameter Leading Digit Default Blank Value Range Up to 3 digits consisting of 0 9 or X Description Function Specifies the leading one two or three digits of the number for TIE calls Used to determine the trunk group for routing a TIE call Note e X can be used as a wild card character which substitutes any digit in its position Reference 3 1 TIE Line Features F G TIE Line Service Parameter Digits to delete Default 0 Value Range 0 16 Description Function Specifies the number of digits to be deleted from the dialed digits Reference 3 1 TIE Line Features F G TIE Line Service Parameter Number to be added Default Blank Value Range Up to 20 digits consisting of 0 9 Description Function Specifies the dialing number to be added to the dialed digits Reference 3 1 TIE Line Features F G TIE Line Service Parameter Trunk Group No Default None Value Range None 1 48 Description Function Specifies the trunk group hunt sequence to be used when placing a TIE call The sequence is commonly used by all tenants but trunk group will be skipped if it does not belong to the same tenant as the caller Reference 3 1 TIE Line Features F G TIE Line Service Programming Guide DID Dial Section 9 DID Dial Progra
124. d will light Reference None Programming Guide System Section 2 System Programming Guide 75 System 2 1 System Used to assign parameters which affect system wide operation fi TD500 Maintenanc 76 Programming Guide System 2 2 Tenant Used to assign various parameters on a tenant 1 8 basis Fem Ca ef Ca e foo few fos 03 oo aw fos ea ea a eS m ea Ca a ea cnt ac fos ap coal Sel kf foo few oo rw oo em foo ew xl oo ew oo Tew zd oo femi L m m m m m m ATAATA ERENER EOLOCOE ik LOHLGEL clea EEGEEEE m m m m m m m 39033 ad o seo cane eee Parameter Tenant No Default 1 Value Range 1 8 Description Function Specifies the tenant 1 8 which you are going to program Reference e 1 3 System Features F G Tenant Service Parameter Operator FDN Default Blank Value Range 3 4 digits consisting of 0 9 Description Function Specifies the FDN Floating Directory Number of Extension Group or Incoming Group Calls by the feature number for Operator Call will reach to this destination Reference e 1 3 System Features F G Programming Guide Floating Station e 1 6 Originating Features F G Operator Call 77 System Parameter Alert Extension Day Night Default Blank Value Range 3 4 digits consisting of 0 9 Description Function Specifies the destination extensi
125. dditional parameters are required as follows Key Type Additional Parameters Description ONE TOUCH Dial Specifies the telephone number or feature access number up to 24 digits consisting of 0 9 x P S or F Note e P Pause S Secret Dialing F Hook Flash Name Specifies the name for One Touch Dialing up to 10 characters consisting of 0 9 A Z a z or the following marks 1 X lt gt amp VTR DN Specifies the Directory Number of the Voice Mail extensions Parameter Key Type Default Value Range Description Function Reference 228 Not Stored Please refer to Description Function Not Stored Key Type is not assigned ONE TOUCH One Touch Dialing button FWD DND Call Forwarding Do Not Disturb button SAVE Saved Number Redial button ACCOUNT Account Code entry button CONF Conference button VTR Voice Mail Transfer button ANSWER Answer button RELEASE Release button e 2 2 3 Flexible Button Assignment U M Programming Guide Line 4 3 4 Extension Line 2 2 Used to assign parameters for extension lines 4 2 Extension Line 2 2 Mosese z z ON foo zeaension mea l ok amy cancer Hee Parameter Intercept Destination Day Night Default Value Range Description Function Reference Programming Guide Blank 3 4 digits consisting of 0 9 Specifies the destination e
126. de Parameter Paired Extension Default Value Range 3 4 digits consisting of 0 9 Description Function Displays the extension paired with the DSS Console Reference e 1 15 Proprietary Telephone Features F G DSS Console Parameter DSS Console 1 8 Port No Default Display only Value Range Extension port physical number Description Function Displays the extension port to which the DSS Console is connected Reference e 1 15 Proprietary Telephone Features F G DSS Console e 1 4 Extension Port Assignment P G Parameter DSS Console 1 8 Model Default T7440 Value Range 1 T7440 2 T7441 3 Others Description Function Specifies the Model No of DSS Console Reference e 1 15 Proprietary Telephone Features F G DSS Console Parameter DSS Key Default Value Range Description Function You can enter into Flexible DSS Key screen Section 4 4 1 by clicking DSS Key on this screen Reference e 2 2 3 Flexible Button Assignment U M Programming Guide e 5 2 1 Station Programming U M 233 Parameter PF Key Default Value Range Description Function You can enter into Flexible PF Key screen Section 4 4 2 by clicking PF Key on this screen Reference e 2 2 3 Flexible Button Assignment U M e 5 2 1 Station Programming U M Parameter Copy Default Value Range Description Function You can enter into DSS Console Copy scre
127. de Default CR LF Value Range 1 CR LF 2 CR Description Function Specifies the NL New Line Code for your printer or personal computer If your printer or personal computer automatically feeds lines with a carriage return select CR Carriage Return If not select CR LF Line Feed Reference None Parameter Serial Interface Port PROG Word Length Default Display only Value Range 8 bits Description Function Defines the number of bits in each byte or character Note e Port 1 is fixed to 8 bits Reference None Parameter Serial Interface Port PROG Stop Bit Default Display only Value Range 1 bit Description Function A stop bit code indicates the end of a bit string which composes a character Select an appropriate value depending on the requirements of your printer or personal computer Note e Port 1 is fixed to 1 bit Reference None Programming Guide Maintenance Parameter Serial Interface Port PROG Baud Rate Default 9600 bps Value Range 1 2400 bps 2 4800 bps 3 9600 bps 4 19200 bps Description Function Specifies the data transmission speed from the system to the printer or personal computer Reference None Serial Interface Port SMDR Port 2 Please refer to Station Message Detail Recording SMDR of Section 1 3 System Features in the Features Guide Note e Generally speaking you should connect your Programming PC to Port 1 and your SMDR printer to Port 2 Parameter Ser
128. de Deny Enable Released Link Operation Disable Digits Restriction in CO Talk Mode Unrestricted Automatic Hold Disable SDN COS Own Extension Programming Guide 365 Default Values 2 4 2 Trunk Group Setting Program Default Trunk Group No 01 48 Day Night All Check 2 4 3 Class of Service COS 2 2 Program Default Secret Busy Override Disable Transferring CO dial tone exempted from TRS Enable Transfer to TIE Disable Incoming Group FWD Disable 2 5 System Timer 2 5 1 System Timer 1 2 Program Default Hold Recall Time 60 s Transfer Recall Time 12 rings Pickup Dial Waiting Time ls Call Duration Count Start Time Os First Digit Time 10s Inter digit Time 5s Call Forwarding No Answer Time 3 rings Extension to CO Line Call Duration Time 10 min CO to CO Line Call Duration Time 10 min Door Opener Time 5s 2 5 2 System Timer 2 2 Program Default Timed Reminder Ringing Time 30s Call Parking Recall Time 60 s TIE Inter digit Time 5s 366 Programming Guide Default Values Program Default DISA Prolong Time 3 min DISA Delayed Answer Time 1 ring Timed Reminder Arrive Count 3 times DISA Automated Attendant Time ls DISA IRNA Time 60 s Intercept Timer after OGM 5s Auto Shut off Time 15s Timed Reminder Arrive Wait Time 60 s Intercept Time Day 12 ring
129. default an S CO button assigned to a DSS button on a DSS Console is available for monitoring the call activity only not available for making receiving a call If this parameter is enabled an S CO button on a DSS Console can be used to answer the incoming CO call on the S CO button and retrieve the CO call held on the S CO button Reference e 1 16 Button Features F G Button Line Access Parameter 49 LCD Display Mode while CO talking Default Caller ID Value Range 1 Caller ID 2 Duration Description Function Specifies the initial display Caller ID or Call Duration which is shown on the display while CO talking Reference e 1 5 Attended Features F G Programming Guide Caller ID Service 143 System 2 8 5 System Option 5 Used to assign system option parameters No 56 No 60 tem Option 6 56 Redial with ISDN Do not send dials entered during conversation C Send dials entered during conversation 57 PS Auto Configuration Mode gt Create mailboxes only for the tenant which has VPS ports C Create mailboxes of all tenants 58 Release of BRI PRI line while talking when DISCONNECT signal is received C Release DontRelease 59 ARS Call Timeout Mode LocalAccess Disconnect 60 Empty Group Allow C Disallow m Option 5 OK Apply Cancel Help Parameter 56 Redial with ISDN Default Do not send dials entered during conversati
130. digits consisting of 0 9 or Description Function Specifies the FWD to Extension Ringback Tone code Sent to the Voice Mail port when the extension dialed is forwarded to another non voice mail extension Reference e 1 3 System Features F G Voice Mail Command Integration VPS Voice Mail Commands are used to control the activity of Voice Mail port There are the following four Voice Mail Commands Leave Message Get Message AA Automated Attendant Service and VM Voice Mail Service A unique code dialing digits up to 16 digits can be assigned to each command Parameter Voice Mail Command Leave Message Default H Value Range Up to 16 digits consisting of 0 9 x or H Description Function Specifies the Leave Message command This command is transmitted to a VM port when a call is forwarded intercepted or rerouted to the VM port Reference e 1 3 System Features F G Programming Guide Integration VPS 267 Features 268 Parameter Voice Mail Command Get Message Default H Value Range Up to 16 digits consisting of 0 9 x or H Description Function Specifies the Get Message command This command is transmitted to a VM port when the message receiver presses the MESSAGE button to retrieve a voice message Reference e 1 3 System Features F G Integration VPS Parameter Voice Mail Command AA Service Default 8 Value Range Up to 16 digits consisting of 0 9 x or
131. during Day Night mode respectively Reference e 1 5 Attended Features F G Direct Inward Dialing DID e 2 3 ISDN Attended Features F G Direct Inward Dialing DID 2 3 Numbering Plan P G Other PBX 01 Other PBX 16 Parameter Name Default Blank Value Range Up to 10 characters consisting of 0 9 A Z a z or the following marks lt gt amp Description Function Specifies the name for the destination extension where a DID call comes in Reference e 1 5 Attended Features F G Programming Guide Direct Inward Dialing DID e 2 3 ISDN Attended Features F G Direct Inward Dialing DID 305 DID Dial 9 2 2 Automatic Registration of DID MDN Numbers Provides quick registration of DID MDN numbers Up to 100 entries can be registered at once with a simple operation 1 Click Automatic Registration on 9 1 DID Dial Registration screen e Automatic Registration screen is displayed Automatic Registration Base Number Dial Max 15 Digits Additional Number Number of Registrations ka Number of Digits 2 z Beginning Entry No 1 991 Execute Cancel Help 2 Enter the appropriate parameters Programming Example Base Number Dial 123456 Additional Number Number of Registrations 100 Additional Number Number of Digits 2 Beginning Entry No 1 306 Programming Guide DID Dial 3
132. e Description Function Enables or disables switching the Day Night Lunch Break service on a Class of Service COS basis Reference e 1 3 System Features F G Night Service e 4 3 48 Night Service On Off U M Parameter Call from TRS Level 7 Extension Default Enable Value Range 1 Enable 2 Disable Description Function If set to Enable TRS level 7 extension users can call the extensions with this COS level Reference e 1 6 Originating Features F G Toll Restriction Parameter Time Limit of Outside Calls Default No Value Range 1 Yes 2 No Description Function Specifies whether to restrict the duration of outside calls or not Notes e Ifset to Yes the system disconnects a CO call originated or answered by the programmed extension user when the time specified by Extension to CO Line Call Duration Time 1 64 min in Section 2 5 System Timer expires e This setting may apply to Outgoing call only or Both calls depending on 5 Limited call duration setting in Section 2 8 System Option Reference None Programming Guide 105 System 106 Parameter Transfer to CO Default Disable Value Range 1 Enable 2 Disable Description Function Enables or disables Call Transfer to Trunk feature Reference 4 3 16 Call Transfer U M Parameter Call FWD to CO TIE Default Disable Value Range 1 Enable 2 Disable Description Function Enables or disables Call Forwarding to Trunk feature
133. e Program Default Time A B C D SUN MON TUE WED THU FRI SAT Time A 8 00AM Time B 5 00PM Time C 9 00PM Time D Disable 7 3 Leading Digits Table Program Default Entry No 001 020 Dial Blank Routing Plan No None 382 Programming Guide Default Values 7 4 Routing Plan Program Default Plan No 1 Time A B C D Trunk Group No None Time A B C D Modification Table No None 7 5 Digits Modification Table Program Default Entry No 01 08 Digits to delete 0 Number to be added Blank 8 Private Network 8 1 Private Network 8 2 TIE Routing Table Program Default Entry No 01 08 PBX Code Blank Leading Digit Blank Digits to delete 0 Number to be added Blank Trunk Group No None 9 DID Dial 9 1 DID Dial 9 2 DID Dial Registration 9 2 1 DID Dial Registration Program Default Entry No 0001 0010 Programming Guide 383 Default Values Program Default Automatic Registration DID MDN No Blank Tenant No 1 VPS Trunk Group No 1 Destination Day Night Blank Name Blank 9 2 2 Automatic Registration of DID MDN Numbers Program Default Base Number Dial Blank Additional Number Number of Registrations 10 entries Additional Number Number of Digits 2 digits 00 99 Beginning Entry No
134. e 1 Keep Rec 2 Stop Rec Description Function Assigns whether to close the mailbox or keep recording the conversation after a call is interrupted Reference e 1 9 Answering Features F G Live Call Screening LCS Parameter LCS Setting LCS Password Default Blank Value Range Fixed to 3 digits consisting of 0 9 Description Function Specifies the 3 digit password for LCS settings Reference e 1 9 Answering Features F G Live Call Screening LCS e 4 3 43 Live Call Screening LCS U M Parameter Data Line Mode Default No Value Range 1 Yes 2 No Description Function Assigns whether Data Line Security mode is available or not If set to No setting Data Line Security mode by dialing the feature number is impossible Reference e 1 12 Conversation Features F G Data Line Security e 4 3 25 Data Line Security U M Parameter Call Waiting Tone Type Default Tone 1 Value Range 1 Tone 1 2 Tone 2 Description Function Specifies the type of Call Waiting Tone for PT extensions Please refer to Section 6 1 3 Tone List in the User Manual for detailed information on Tone Type Reference e 2 2 2 Call Waiting Tone Type Assignment U M Programming Guide e 4 3 17 Call Waiting U M 219 Line 220 Parameter Call Pickup Deny Default Disable Value Range 1 Enable 2 Disable Description Function Enables or disables Call Pickup Deny mode Reference e 1 9 Answering Features F G Call Pickup
135. e KX TD500 system Note e The DID MDN number which has already been assigned cannot be registered Reference e 1 5 Attended Features F G Direct Inward Dialing DID e 2 3 ISDN Attended Features F G Direct Inward Dialing DID Multiple Directory Number MDN Ringing Service Parameter Tenant No Default 1 Value Range 1 8 Description Function Specifies the tenant used for DID call when Enable is specified in VM Trunk Service for DID programming in Section 2 8 System Option Reference e 1 5 Attended Features F G Direct Inward Dialing DID e 2 3 ISDN Attended Features F G Direct Inward Dialing DID 2 8 System Option P G VM Trunk Service for DID Parameter VPS Trunk Group No Default 1 Value Range 1 48 Description Function Specifies the trunk group used for the call to the VPS when Enable is specified in VM Trunk Service for DID programming in Section 2 8 System Option Reference e 1 5 Attended Features F G Direct Inward Dialing DID e 2 3 ISDN Attended Features F G Direct Inward Dialing DID 2 8 System Option P G VM Trunk Service for DID Programming Guide DID Dial Parameter Destination Day Night Default Blank Value Range 3 4 digits consisting of 0 9 Description Function Specifies the DN FDN Extension Group TAFAS Phantom Extension Remote Resource OGM Group Incoming Group and the other PBX extension numbers where a DID call comes in
136. e Range 1 Enable 2 Disable Description Function Enables or disables sending pulse dialing signals during an outside call Reference None Programming Guide 129 System 130 Parameter 12 Automatic adjustment of the clock using Caller ID information Default No Value Range 1 Yes 2 No Description Function Enables or disables the automatic adjustment of the clock by Caller ID information once a day Reference e 1 5 Attended Features F G Caller ID Service Parameter 13 DISA prolong operation Default No limit Value Range 1 Limited 10 times 2 No limit Description Function Specifies the number of times that the DISA caller can prolong the duration of DISA CO to CO line call Reference e 1 5 Attended Features F G Direct Inward System Access DISA Parameter 14 Dialing in DISA CO to CO talking Default Disconnect and make a new call Value Range 1 Disconnect and make a new call 2 Send out Dial Description Function The X key can be entered during a DISA CO to CO line call The action taken by the system depends upon this setting If Disconnect and make a new call is selected then the system will disconnect the current call and prepare for a new call Otherwise the will be transmitted down the line to the other party Reference e 1 5 Attended Features F G Direct Inward System Access DISA Programming Guide System Parameter 15 Special dial tone after se
137. e call compulsorily Note e If an unavailable OGM S 1 8 is assigned in the UCD Time Table it will be ignored 3 3 Extension Group P G 3 5 Incoming Group P G Programming Guide Toll Restriction Section 6 Toll Restriction Programming Guide 281 Toll Restriction 6 1 Toll Restriction Used to assign TRS Toll Restriction Deny Codes and TRS Exception Codes TD500 Maintenance Ey 282 Programming Guide Toll Restriction 6 2 TRS Deny Code Used to program a list of up to 400 TRS Toll Restriction Deny Codes telephone numbers that extension users cannot dial 6 1 TRS Deny Code Parameter TRS Level Default 6 Value Range 2 6 Description Function Specifies a TRS toll restriction level Reference e 1 6 Originating Features F G Toll Restriction Parameter Entry No Default 001 020 Value Range 001 400 in 20 entries increments Description Function Specifies a unit of 20 TRS Deny Codes which apply to the TRS level selected Reference e 1 6 Originating Features F G Toll Restriction Programming Guide 283 Toll Restriction Parameter Dial Default Blank Value Range Up to 10 digits consisting of 0 9 X x or Description Function Specifies the leading 10 digits of the toll restricted telephone numbers Note e X can be used as a wild card character which substitutes any digit in its position
138. e destination 1 2 1 Slot Assignment Assigns the type of service cards inserted in the free slots in the basic and expansion shelves Section 1 2 Slot Assignment consists of the following sub sections 1 2 1 Slot Assignment 1 2 2 Card Properties HLC SLC OPX SLC M 1 2 3 Card Properties DHLC ESLC DLC 1 2 4 Card Properties LCOT GCOT 1 2 5 Card Properties ELCOT 1 2 6 Card Properties ELCOT Caller ID 1 2 7 Card Properties T1 1 2 8 Card Properties BRI 1 2 9 Card Properties BRI SPID DN 1 2 10 Card Properties PRI23 1 2 11 Card Properties BRI PRI23 ISDN Protocol Timer 1 2 12 Card Properties DISA 1 2 13 Card Properties ERMT 10 Programming Guide Configuration 1 2 14 CPU Card Information 1 2 15 TSW Card Configuration 1 1 Slot Assignment pits ETE m ETA E EE e 4 Ket Lell ELL el lel LLULeLLeLLLE 1 1 Slot Assignment M Programming Guide 11 Configuration 12 Parameter Card Type Default Value Range Description Function Reference Blank Please refer to Description Function Specifies the type of service cards inserted in the free slots in the basic and expansion shelves lt Selection gt None Not assigned AGC Automatic Gain Control card BRI ISDN Basic Rate Access Interface card DHLC Digital Hybrid Line Circuit card DID Direct Inward Dialing Trunk card DISA Direct Inward System Access card DLC Digita
139. e from PBX when connecting PC to PBX directly using an RS 232C Cable E0011 No response from the modem Cannot detect a response from the modem because a modem is not connected to PC or the communication port COM parameter of PC is not correct 338 Programming Guide Programming Error Messages Error Message Error Code Description E0012 Another maintenance device is connected There are three ways to access the PBX 1 By PC System Programming 2 by Remote System Programming or 3 by User Programming But only one at a time E0013 Please reconnect after the PBX becomes on line or off line completely Tried to connect the PC before the PBX became on line or off line completely Please try after the off line indicator on the top shelf goes off on line or turns on and off off line E0014 Please enter profile name Attempted to save remote connection parameters without profile name E0015 Failed Saving of remote connection parameters Remote connection parameters are saved as a file TD500 INI in the Microsoft Windows operating system directory The TD500 maintenance program creates this file automatically if the file does not exist However if the file exists and it is damaged you will get this error message You must either repair the damage using a text editor or rename it as a different file E0016 Failed Deletion of remote connection parameters Deletion of remote con
140. eaece gt 166 Pagine Group cnsssecvscscscveccetisccesscsacedecescesecossesecosestaccsestsenseseestcesencdeeacessbesssseeesscseueseceseoss 179 INCOMING Group sveedescevssesesvcseceeecsbecesssescecascacesssedasedssocacdssoesusasacctsessscucessacussssoesesasssanss 180 OGM Groups isisisi sosedo snosio a eorn sorsia oos r rors ss or SEE o ToS rn ois Es Se 193 lE E E A EE AAE ARTTE LoD IDin T T E E E E EAE 198 Tronk Am oaiae an a A ANENA Aa 199 Extension Line 2cc ccsaccccasdnscosdcassotectdentecatcsceveccstasesdaseosacesuassessnsbenecccsatecsccevocsssbarsenesssens 211 DEE OIS 11 A S E S E S 231 Poor POMC ernaar AE EE REE E A N 240 External Paging arici anna r Sia 242 ISDN Extension Line eso ssesoesossossocssesossosesesosseseossossessossossossocsossossossossossossossossossose 244 FG ACUTOS aicssdennssisssncasnesansasunasunsccsevesseccabssswasdonusniansedsesesdectasawsentuntonaesceo MN a siscccescccasertsconsseosnsessusccendsscnnocsvssescuscouanstenadovesesdessvsnsesesacdenssseneacsbassecesscessesucseonss 250 System Speed Dialing ss ccccssscssessosssssensvccssssonnesevesssessesensssoecsesvncssessesnsenssesnsessssenestoess 251 Phantom Extension cos s cccccccesessscestesssescecescscecsossdesssecencsssesscsasscscssasesessessecssbassesesassesees 254 Emergency Dial Codes cccccssccdsccccsscttcetleet cacdcee caccutt coceuntec cundeacchibeatecchaaecacsenecacsssedscsedsess 256 QUICK DIALING asaan Aa AA AEA EEO Aa A 257 Account Cod t sorosoro a e ri saio toons
141. ecssescacesedeacssedecevers 69 PRI Port ASSIGHMENL cccvcccscscscescsesecesesevessecenecsosenccessevecessuccctecucssonsecceocsescescassesocasesessns 72 RALI ai ONA ois cs sco EA AA AE AEE f SYSCEM ONT EA EA A E O I I R OAOE E EANES 76 Tenant 2 sccsscssccsessscdusecasevscsscvesvesesscuscenssescsessuscetonascedsooduacsensssessosesecsecsseshenestassonacsoeaadesuasss 77 Num Dering Planievsc svecccsssivecessecesceseceeceseccveeseccuccseccuccssstecctsveccesesecesenducesecuecesssnsbesssasscessns 84 Class of Service COS issevecsscese ds sadnss oxsecasoadbcanessaconsodsocnossuatacssvecoenedsdsevedescesesssdacsossiens 103 System Timers ssvcccissiivcsssvesecedscscceesacevcnedsntsveassoscnevss ess oira Ek ESSEKS Seanin riese taies 113 Local Hunt Seguente nianiar R Aa 123 Trunk to Trunk Restriction eossoessssooesscoesesoosssoosessoesesoosssooseessossssooessoossssoosssoossssooe 124 System Optom ecssccvectsdicseacdecsecetesseascsecescteccsacceecsecscsedescceesesdbedenscecdivectesarusiesivesceeaveaseadve 125 PRI Originating Control e sooesscocsssoocsscosssssoecssoosssocesesoosesooesssosesesooessoossesosssscosssoo 148 OSUI a E ett ees eee eee eet OD MG HOU PD PERA EE TAN EIEI E EIA E A E N E EEN ES EAEE A A T 152 Trunk Grou sisssscsscscscssccescssccencsescentesccvecesecsscuececcdeccecesscsecessteccesstesessutcsscsencesenscesertecues 153 Extensi n GrOUD sicsessvvccesticcesssccessoes ceszeccescoesevecvecccestesteectescesedseecesseaeseseetecessennsccset
142. ed the system assumes that the first digit is a DISA built in auto attendant number Reference e 1 5 Attended Features F G Direct Inward System Access DISA Programming Guide System Parameter DISA IRNA Time Default 60 s Value Range 5 240 s Description Function Specifies the length of time in seconds the system is to wait before activating IRNA Intercept Routing No Answer feature for DISA calls If a DISA call directed to a single extension is not answered within this timer the system redirects the DISA call to another pre programmed IRNA destination Note e Call Forwarding No Answer Time will override this timer if an extension has enabled Call Forwarding No Answer Reference 1 5 Attended Features F G Direct Inward System Access DISA Parameter Intercept Timer after OGM Default 5s Value Range 1 0s Immediately 2 5s 5 s later Description Function Specifies the length of time in seconds the system is to wait after sending OGM before directing the call to the IRNA destination Reference e 1 5 Attended Features F G Direct Inward System Access DISA Parameter Auto Shut off Time Default 15s Value Range 1 3s 2 15s Description Function Specifies the length of time in seconds after receiving a disconnect signal during a hands free conversation with an outside call before the speakerphone is turned off Reference None Programming Guide 121 System 122
143. ed to this system via TIE Line If set to No the system does not recognize a switchhook flash Reference e 1 3 System Features F G T1 Carrier Parameter Flash Detection Timer Default 208 1016 ms Value Range 1 208 1016 ms 2 80 1016 ms 3 208 1544 ms 4 80 1544 ms Description Function Specifies the time range in milliseconds that the system requires to recognize a switchhook flash Reference e 1 3 System Features F G T1 Carrier Programming Guide Configuration Parameter Answer Decision Timer Default 32 ms Value Range 32 8160 ms in 32 ms increments Description Function Specifies the time range in milliseconds that the system requires to recognize the answer signal Reference e 1 3 System Features F G T1 Carrier Parameter Break Detection Default 16 96 ms Value Range 1 16 96 ms 2 16 136 ms Description Function Specifies the break detection length Reference e 1 3 System Features F G T1 Carrier Parameter Transmission of RAI Default No Value Range 1 Yes 2 No Description Function Specifies whether to send or not RAI Remote Alarm Indication signal to the Central Office Note e This setting is valid when the LPR software version of the T1 card is Y311D or later Reference None Programming Guide 29 Configuration 1 2 8 Card Properties BRI Used to assign the parameters for the BRI Basic Rate Interface card When you change the card properties the card
144. efault Disable Value Range 1 Enable 2 Disable Description Function Specifies whether the Intercept Routing feature on an incoming TIE call is enabled or not Reference e 1 11 Transferring Features F G Programming Guide Intercept Routing 4 2 Trunk Line P G 165 Group 3 3 Extension Group Used to assign various parameters for up to 128 1 128 Extension Groups Which parameters apply to your Extension Group Please refer to the table on the Page 167 and Page 168 Note e By default the Group Type of Group No 126 is VM No 127 is AA and No 128 is Operator 3 2 Extension Group OVEM OVSENO WESITTalon Way Destination Miatit MEN ET CERT GUTTTG E Een sith Gall E 166 Programming Guide Group Applicability of Parameters to Group Types Group Type Parameter None Ter Cir Ring Ope VM AA UCD Group No Vv Vv Y v Vv Vv Y v FDN Vv Vv Vv Vv Y Y Y Vv Tenant No Vv Vv Vv Vv Vv Y Y Y Overflow Setting Vv Vv Vv Vv Vv Y Destination Day Night Overflow Setting Timer Vv FWD DND Mode Y Vv Vv Vv Extension Call Hunting Y Y Calls to Empty Group Vv Y Operator Setting Y Ringing Type Operator Setting Y Call Priority UCD Setting Y Time Table No UCD Setting Vv FWD No Answer UCD Setting Vv Auto LOGOUT Mode UCD Setting Vv Supervisor Extension UCD Setting Y LOGIN Monitor UCD Setting Y UCD
145. eference e 4 3 36 External Modem Control U M Parameter 62 Reserved Reserved for future use Default Blank Value Range Description Function Reference Parameter 63 70 Quick dial 1 Quick dial 8 Default Blank Value Range 1 4 digits consisting of 0 9 or Description Function Specifies the feature number for Quick dial features Reference e 4 3 65 Quick Dialing U M Parameter 71 Reserved Reserved for future use Default Blank Value Range Description Function Reference Parameter 72 Remote DND Default 722 Value Range 1 4 digits consisting of 0 9 or Description Function Specifies the feature number for setting canceling the DND Do Not Disturb feature for other extensions For Manager Operator only Reference 4 4 7 Remote DND Do Not Disturb Control U M Programming Guide 97 System 98 Parameter 73 Remote FWD Cancel Once Default 723 Value Range 1 4 digits consisting of 0 9 X or Description Function With this feature number the Manager or the Operators can reach an extension that has set Call Forwarding It is one time once cancellation not a permanent cancellation of Call Forwarding on the destination For Manager Operator only Reference e 4 4 8 Remote FWD Call Forwarding Cancel Once U M Parameter 74 Trunk Route Control Default 724 Value Range 1 4 digits consisting of 0 9 or Description Function Specifies the feature number for T
146. en by clicking this button Reference 4 4 1 Flexible DSS Key Assignment Used to determine the usage of flexible DSS buttons on DSS Consoles The following screen is displayed by clicking Flexible DSS Ke DSS Key on 4 3 DSS Console screen 234 Programming Guide Line lt Key Type Assignment gt The following Key Type Assignment screen is displayed by clicking Key Type Display button including Not Stored for each DSS Key on the above screen Flexible DSS Key 1 Key Type ERT Wwounkine HG wal Ringing wee Not Stored ha Immediate OK Cancel Help lt Additional Parameters Required by Key Type gt Depending on a Key Type additional parameters are required as follows Additional EPT Key Type Parameters Description SINGLE CO Trunk Line Specifies the trunk port physical number 10101 to 31416 No GROUP CO Trunk Group Specifies the Trunk Group number 01 48 No DSS EXT Specifies the extension number 3 or 4 digits ONE TOUCH Dial Specifies the telephone number or feature access number up to 24 digits consisting of 0 9 x P S or F Note e P Pause S Secret Dialing F Hook Flash MESSAGE EXT Specifies the extension number or phantom extension OTHER number 3 or 4 digits G FWD DN Specifies the Floating Directory Number of the Incoming Group VTR DN Specifies the Directory Num
147. ence determined by this Call Priority setting e Ifthe same priority is set on all four types of calls the calls will be put in the waiting queue in order of the arrival Reference e 1 3 System Features F G Programming Guide Operator Group e 1 6 Originating Features F G Operator Call 177 Group Parameter Operator Setting Ringing Type Default Single Value Range 1 Multi 2 Single Description Function Specifies whether the calls coming in on an Operator Group ring one Operator Single or all Operators in the group Multi simultaneously Assignable only when Operator is specified in Group Type programming Reference 1 3 System Features F G Operator Group e 1 6 Originating Features F G Operator Call 178 Programming Guide Group 3 4 Paging Group Used to program up to 16 Paging Groups Each Paging Group consists of up to 24 Extension Groups One Extension Group can be assigned to only one Paging Group 3 3 Paging Group Parameter Paging Group No Default 1 Value Range 1 16 Description Function Specifies the Paging Group 1 16 which you are going to program Reference e 1 14 Paging Features F G Paging e 4 3 55 Paging U M Parameter Extension Group No Default Paging Group No 1 No 1 1 No 2 128 Others None Paging Groups No 2 16 All None Value Range None 1 128 Description Function Specifies the Extension Group w
148. ence e 1 5 Attended Features F G Caller ID Service Parameter Header Examination Default Enable Value Range 1 Enable 2 Disable Description Function Activates or deactivates the examination of header information of Caller ID signal Note e This item must be Enable in case you use Caller ID feature Reference e 1 5 Attended Features F G Caller ID Service Parameter LPR Version Default Display only Value Range 0 15 Description Function Displays the LPR Software Version Reference None Programming Guide 23 Configuration 1 2 7 Card Properties T1 24 Used to set the parameters for the T1 card When you change the card properties the card status must be OUS Out of Service Card Properties 101 T1 r Line Coding mInter digit Pause e30 ms x r Frame Sequence ESF iad Flash Detection C Yes f No ESF Frame Option C A D B x 208 1016 ms x Flash Detection Timer m First Dial Timer CO 1 0s x 32 ms x Answer Decision Timer m First Dial Timer DID TIE 64 ms x 16 96 ms 7 m Break Detection m Break C 60 C 67 Pulse Feedback Tone Yes No m Transmission of RAI C Yes No Signaling Bit Monitor r Software information Version 311D020913 Check Sum even 5249 odd E474 Disable x Mode 3 Parameter Line Coding Default B8ZS Value Range 1 B8ZS 2 AMI Description Function
149. er W1003 Make sure the card is OUS before changing the Card Properties Tf the card is already OUS to change the properties or just to view Card Properties click OK To change the card to OUS click Cancel W1004 DTMF Caller ID code must not exceed 16 characters Truncate it Truncate means that the leading 16 characters are saved and the rest are deleted W3001 PBX code must not exceed 4 digits Truncate it Truncate means that the leading 4 digits are saved and the rest are deleted W3002 Please verify that previously erased FDN is not programmed in other screens The erased FDN may be used in other screens Ww4001 Trunk name must not exceed 10 characters Truncate it Truncate means that the leading 10 characters are saved and the rest are deleted Programming Guide 349 Programming Error Messages Message Code Description Ww4002 Extension name must not exceed 10 characters Truncate it Truncate means that the leading 10 characters are saved and the rest are deleted W4003 One Touch dial number must not exceed 24 digits Truncate it Truncate means that the leading 24 digits are saved and the rest are deleted W4004 CLIP number must be less than 16 digits Truncate it Truncate means that the leading 16 digits are saved and the rest are deleted W4005 One Touch dial name must not exceed 10 characters Truncate it Truncate means that the leading 10
150. es Executive Busy Override Deny feature Note e Executive Busy Override Deny allows the extension user to prevent Executive Busy Override from being executed by another extension user Reference e 4 3 34 Executive Busy Override Deny U M Programming Guide 107 System Parameter Released Link Operation Default Value Range Description Function Reference Disable 1 Enable 2 Disable Used to turn on off Released Link Operation mode of the extension When Released Link Operation is enabled an extension user will be automatically released from a call extension outside after transferring it to the destination if the destination extension is idle This feature simplifies the transfer operation by eliminating the need for going on hook or pressing the RELEASE button after transferring the call This feature is convenient for extension users such as Operators who handle a large volume of calls e 1 3 System Features F G Released Link Operation e 4 3 67 Released Link Operation U M Parameter Digits Restriction in CO Talk Mode Default Value Range Description Function Reference 108 Unrestricted 1 Unrestricted 2 1 15 the digits to be dialed out Specifies the maximum number of digits that can be dialed during a CO call If the outside party hangs up during a CO call and the extension user tries to dial out while still on the same CO line the system will disconnec
151. esseenscssesoress 311 10 3 External Modem 2 2 sesessssocececessesccecessosocecessssoceccesessssoccecsssscscccsesscsoececssssoccceceessso 313 10 4 SMDR ogeicscesits ecececsscesessaceceisssecesseeteausessescessseaestesescstesseesTessensvessedeseseedessasedsasdeessasussens 314 10 5 Power Failure Transter cccciccccescsccscsossscnesecvecscovotsscsestccccevecsoasesteossenocdsssevssscestesceoseea 320 10 6 Syst m PArameters siisvecvsssssssssccsssvessensvsseceosevesnoscescnsssvsbesnavsvocavovecesnadecsnsessesnseosees 322 10 7 System Tinie iseccesesaisceccencecscessbucscsvtssesessveccoonstevedsvesccsdencssoccdeecssusscovendesecseeneestagsee entene 330 11 Programming Error Messages ccscsssscccsssssssssccssssssssssseses SOT TLL Error Messages E X XXX cccccccccceiccicecdccsdcvedcecactcsccasedscdcnvsdsedcccenedceseeseccsensccesen ssesciss 338 11 2 Warning Messages WXXXX sccsscsccssssscsssssssssssssscssssssscssesssssssscsssssssssssessseees 349 11 3 Information Message IXXXX ccsscccssssccssssssscssssssscssssssssssssscesessescsssssssssseses 352 12 gt De fault VANES sccossisececive hs ices ecocstense ioe aes OO Programming Guide Configuration Section l Configuration Programming Guide 5 Configuration 1 1 Configuration Used to determine the basic system configuration j TD500 Maintenance Console Programming 1 Configuration 1 1 Slot Assignment Programming Guide Configuration
152. eter Inter digit Pause Default 830 ms Value Range 1 630 ms 2 830 ms 3 1030 ms Description Function Used to distinguish between each pulse signal To meet the requirements of your Central Office select the appropriate value that represents the delay between dial pulses This setting is only required when using dial pulse trunks Reference None Parameter Pulse Break Time Adjustment Default 0 ms Value Range 16 to 16 ms in 4 ms increments Description Function Specifies the pulse break time for pulse digits Reference None Programming Guide Configuration Parameter Bell Detection Time Default 144 ms Value Range 24 1200 ms in 24 ms increments Description Function Specifies the length of time in milliseconds the system requires to determine that the received signal is the bell signal Reference None Parameter DTMF Inter digit Pause Time Default 112 ms Value Range 64 304 ms in 16 ms increments Description Function Specifies DTMF Inter digit Pause Time Reference None Parameter Bell Disappearance Timer Default 5s Value Range 1 15 s Description Function Specifies the length of time in seconds the system requires to confirm the disappearance of the bell signal from local Central Office Reference None Parameter Gain Adjustment Default 0 dB Value Range 3 to 3dB in 0 5 dB increments Description Function Used to adjust the volume level of the call Reference None Programming
153. etwork Programming Guide 297 Private Network 8 1 Private Network Used to assign parameters required to utilize TIE line service TD500 Maintenan 298 Programming Guide Private Network 8 2 TIE Routing Table Used to specify trunk groups and parameters required for making TIE calls This table is referenced by the system to identify the trunk route when an extension user made a TIE call by dialing the feature number for TIE Line Access or Other PBX 01 16 The first 3 digits other than TIE Line Access Code of the dialed number decide a routing pattern appropriate for each call Up to 36 routing patterns can be programmed in this table 8 1 TIE Routine Table Entry No oe r PBX Code Max 3 Digits Eo 2 3 sf BE go fo JT Leading Digit Digits to Number to be added Max 3 Digits delete Max 20 Digits Trunk Group No hicks LULL None None None None None None None z None 8 1 TIE Routing Table OK Apply Cancel Help Parameter Entry No Default 01 08 Value Range 01 36 Description Function Specifies the entry number of Routing Table which you are going to program Reference e 3 1 TIE Line Features F G TIE Line Service Parameter PBX Code Default Blank Value Range Up to 3 digits consisting of 0 9 Description Function Specifies the ID code for your PBX Require
154. f the trunk line when no digits are dialed before the First Digit timer expires Reference None Programming Guide 141 System 142 Parameter 41 Fixed Feature Number Default Type 1 Value Range 1 Type 1 2 Type 2 Description Function Specifies a type of Fixed Feature Numbers Reference e 1 3 System Features F G Flexible Numbering e 6 1 2 Feature Numbers List U M Parameter 42 DPT Ringer OFF Default Enable Value Range 1 Enable 2 Disable Description Function Specifies whether the Ringing tone of DPTs Digital Proprietary Telephones can be turned off or not Reference None Parameter 43 LCD Time Display Mode Default 12h Value Range 1 12h 2 24h Description Function Specifies the time display on the LCD in 12 hour or 24 hour notation Reference e 1 17 Display Features F G Display Date and Time Parameter 46 Date Display Default M D Y Value Range 1 M D Y 2 D M Y Description Function Specifies a date display format appropriate to your area Reference e 1 17 Display Features F G Display Date and Time Programming Guide System Parameter 47 Tone Type for Outgoing Calls Default Busy Reorder Value Range 1 Busy Reorder 2 Busy 3 Reorder Description Function Specifies a tone type for outgoing calls Reference None Parameter 48 Call Pickup with DSS S CO key Default Disable Value Range 1 Enable 2 Disable Description Function By
155. fies the data transmission speed from the system to the printer or personal computer Reference None Programming Guide Maintenance Parameter Remote FDN Default 1499 Value Range Up to 4 digits consisting of 0 9 Description Function Specifies the FDN Floating Directory Number for Remote Administration Reference e 1 2 System Administration F G System Programming and Diagnosis with Personal Computer e 3 4 3 Remote Administration Remote Connection I M Parameter DN Refer Default Value Range Description Function Displays the list of DNs FDNs which are already assigned to the extensions system resources Reference None Parameter Remote Connect Information Dial Number Default Blank Value Range Up to 40 digits consisting of 0 9 x F P S or hyphen Description Function Specifies the dial number that is sent from the modem remote location You can see this dial number in the Batch Processing mode Reference 3 4 3 Remote Administration Remote Connection I M Parameter Remote Connect Information Comment Default Blank Value Range Up to 40 characters consisting of 0 9 A Z a z or the following marks lt gt amp Description Function Specifies the comment area such as company name You can see this comment in the Batch Processing mode Reference e 3 4 3 Remote Administration Remote Connection I M Programming Guide 329
156. g U M Parameter 27 Station Paging Answer Default 43 Value Range 1 4 digits consisting of 0 9 or Description Function Specifies the feature number for answering the paging announcement through the built in speakers of PTs Reference e 4 3 56 Paging Answer U M Parameter 28 CO Call Pickup Default 4 Value Range 1 4 digits consisting of 0 9 X or Description Function Specifies the feature number for answering a CO call ringing at another extension Reference e 4 3 13 Call Pickup U M Programming Guide 89 System 90 Parameter 29 Group Call Pickup Default 40 Value Range 1 4 digits consisting of 0 9 or Description Function Specifies the feature number for answering a call ringing at another extension in the same Extension Group Reference e 4 3 13 Call Pickup U M Parameter 30 Directed Call Pickup Default 41 Value Range 1 4 digits consisting of 0 9 or Description Function Specifies the feature number for answering a call ringing at another extension Reference e 4 3 13 Call Pickup U M Parameter 31 Hold Default 50 Value Range 1 4 digits consisting of 0 9 or Description Function Specifies the feature number for putting a call on hold and retrieving the call Reference 4 3 11 Call Hold U M Parameter 32 Hold Retrieve Station Default 51 Value Range 1 4 digits consisting of 0 9 or Description Function Specifies the feature number for
157. g data in your PC This is functional when the PC Maintenance Console is connected in the interactive mode Tenant No Entry No Ez 000 019 z Max Entry 1000 Current Registration 0 Entries No Name Number Max 10 Characters Max 24 Digits 5 1 System Speed Dialing z OK any Cancel Help Parameter Tenant No Default 1 Value Range 1 8 Description Function Specifies the tenant to which the System Speed Dialing codes are assigned Required when Tenant Service is employed Reference e 1 3 System Features F G Tenant Service 2 2 Tenant P G Parameter Entry No Default 000 019 Value Range 000 999 in 20 codes increments Description Function Specifies the entry number of the Speed Dialing codes which you are going to program Reference None Programming Guide 251 Features 252 Parameter Max Entry Default Display only Value Range 0 1000 Description Function Displays the maximum number of Speed Dialing codes allocated to the tenant Reference e 1 3 System Features F G Tenant Service 2 2 Tenant P G Parameter Current Registration Default Display only Value Range 0 1000 Description Function Displays the total number of Speed Dialing codes which are already programmed Reference None Parameter Name Default Blank Value Range Up to 10 characters consisting of 0 9 A Z a z or the following marks
158. ge 1 Disable 2 Enable Description Function Specifies whether or not the system sends Follow on ID to a Voice Mail port after redirecting a call IRNA to the Voice Mail port Reference e 1 3 System Features F G Integration VPS Programming Guide Features 5 11 Caller ID Modification Used to modify the telephone number sent from the Central Office by Caller ID Service to make up a telephone number for callback purposes 5 11 Caller ID Modification tT lca TOT 5 11 Caller ID Modification M Parameter Local Call Area Code Default Blank Value Range Up to 6 digits consisting of 0 9 Description Function Specifies the area code of the location where your KX TD500 system is installed Note e This local area code is referenced to modify the telephone number Reference e 1 5 Attended Features F G Programming Guide Caller ID Service 273 Features 274 Parameter Local Call Digits to delete Default No 1 3 Others 0 Value Range 0 9 Description Function Specifies the number of digits to be deleted from the telephone number sent from the Central Office by Caller ID Service to make up a telephone number for local call Digits are removed from the beginning of the received digits Reference e 1 5 Attended Features F G Caller ID Service Parameter Local Call Number to be added Default Blank Value Range Up to 4 digits
159. ges 11 3 Information Message IXXXX Message Code Description 10001 Upload completed Please change PBX to on line mode Uploading the system programming data from PC to PBX is completed How to change PBX to on line mode 1 Set CPU Mode Rotary Switch position to 0 2 Then press Reset button 11000 Please set up VPS port in 1 4 VPS DPT Port Assignment screen The attribute s of extension s have been set up as VPS DPT Please set up the port s in 1 4 VPS DPT Port Assignment screen 352 Programming Guide Default Values Section 12 Default Values Programming Guide 353 Default Values 1 Configuration 1 1 Configuration 1 2 Slot Assignment 1 2 1 Slot Assignment Program Default Card Type Blank Status 1 2 2 Card Properties HLC SLC OPX SLC M Program Default Break Detection 16 96 ms Flash Detection Yes 1 2 3 Card Properties DHLC ESLC DLC Program Default Break Detection 16 96 ms Flash Detection Yes LPR Version Display only Off hook Time 160 ms Flash Detection Timer 208 1016 ms 1 2 4 Card Properties LCOT GCOT Program Default First Dial Timer 1 0s Break 60 Pulse Feedback Tone Yes Inter digit Pause 830 ms 354 Programming Guide Default Values 1 2 5 Card Properties ELCOT
160. ging Features F G Programming Guide Paging e 4 3 55 Paging U M 83 System 2 3 Numbering Plan Used to assign the leading digits of extension numbers and feature numbers for system features 2 2 Numbering Plar 2 2Numberinapian H a poly BE ZOO Parameter 1 1st Hundred Block Extension Default 10 Value Range 1 2 digits consisting of 0 9 Description Function Specifies the leading 1 or 2 digits of the extension number Any number 0 through 9 can be set Notes e If one digit is assigned as the leading digit 3 digit extension numbers can be assigned e Iftwo digits are assigned as the leading digits 4 digit extension numbers can be assigned Reference e 1 3 System Features F G 84 Flexible Numbering Programming Guide System Parameter 2 2nd Hundred Block Extension Default 11 Value Range 1 2 digits consisting of 0 9 Description Function Same as the Parameter 1 Reference e 1 3 System Features F G Flexible Numbering Parameter 3 3rd Hundred Block Extension Default 12 Value Range 1 2 digits consisting of 0 9 Description Function Same as the Parameter 1 Reference e 1 3 System Features F G Flexible Numbering Parameter 4 4th Hundred Block Extension Default 13 Value Range 1 2 digits consisting of 0 9 Description Function Same as the Parameter 1 Reference e 1 3 System Features F G Flexible Numbering Para
161. gits Tone 2 Specifies the ringer frequency ring tone type 1 8 for incoming calls Ringing Type Specifies the timing of ringing when a call comes in on the Immediate extension Immediate 1 ring Delay 3 ring Delay 6 ring Delay No Ring G FWD DN Specifies the Floating Directory Number of the Incoming Group G LOGIN DN Specifies the Floating Directory Number of the Incoming LOGOUT Group ONE TOUCH Dial Specifies the telephone number or feature access number up to 24 digits consisting of 0 9 x P S or F Note e P Pause S Secret Dialing F Hook Flash MESSAGE EXT Specifies the extension number or phantom extension OTHER number 3 or 4 digits Programming Guide 225 Line 226 Additional Key Type Parameters Description default VTR DN Specifies the Directory Number of the Voice Mail extension 2WAY REC DN Specifies the Directory Number of the Voice Mail extension 2WAY TRN IDN Specifies the Directory Number of the Voice Mail extension Parameter Key Type Default Value Range Description Function Reference CO 01 Loop CO Others Not Stored Please refer to Description Function Not Stored Key Type is not assigned SINGLE CO Single CO button GROUP CO Group CO button LOOP CO Loop CO button DSS Direct Station Selection button PHANTOM Phantom button PDN Primary Directory Number button SDN Secondary Directory Number butto
162. hich you are going to assign to the Paging Group Up to 24 Extension Groups per Paging Group can be assigned Reference e 1 14 Paging Features F G Programming Guide Paging 179 Group 3 5 Incoming Group Used to program a list of up to 96 Incoming Groups Which parameters apply to your Incoming Group Please refer to the table on Page 181 and Page 182 3 4 Incoming Dem Setting SUES recall E Some zl 3 4 Incoming Group N 180 iris ETeGy UVDAG TS Wer PUIG EOS OI TCO UCD Calivarinag o ll mE ntercepb Routt EE aes Enable t icayle a ENAERE ADI EAHIE Programming Guide Group Applicability of Parameters to Group Types UCD Call Waiting Group Type Parameter DIL 1 N Ter Ring Ope UCD Overflow Setting Vv Y Y Destination Day Night Overflow Setting Timer Y FWD DND Mode Vv Y Y Search Mode v Y Calls to Empty Group v Y Operator Setting Y Ringing Type Operator Setting Y Call Priority UCD Setting Vv Time Table No UCD Setting Vv FWD No Answer UCD Setting Y Auto LOGOUT Mode UCD Setting Vv Supervisor Extension UCD Setting Vv v assignable 1 Assignable when Operator Single is specified in Group Type programming 181 Programming Guide Group Applicability of Group Types to Overflow Destinations Overflow Destination
163. ial Interface Port SMDR Parity Default None Value Range 1 None 2 Mark 3 Space 4 Even 5 Odd Description Function A parity code indicates what type of parity is used to detect an error in the string of bits composing a character Make an appropriate selection depending on the requirements of your printer or personal computer Reference None Programming Guide 327 Maintenance 328 Parameter Serial Interface Port SMDR NL Code Default CR LF Value Range 1 CR LF 2 CR Description Function Specifies the NL New Line Code for your printer or personal computer If your printer or personal computer automatically feeds lines with a carriage return select CR Carriage Return If not select CR LF Line Feed Reference None Parameter Serial Interface Port SMDR Word Length Default 8 bits Value Range 1 7 bits 2 8 bits Description Function Defines the number of bits in each byte or character Reference None Parameter Serial Interface Port SMDR Stop Bit Default 1 bit Value Range 1 1 bit 2 2 bits Description Function A stop bit code indicates the end of a bit string which composes a character Select an appropriate value depending on the requirements of your printer or personal computer Reference None Parameter Serial Interface Port SMDR Baud Rate Default 9600 bps Value Range 1 2400 bps 2 4800 bps 3 9600 bps 4 19200 bps Description Function Speci
164. ication Presentation number Notes e When an extension user makes an outside call using an ISDN BRI line the number stored in DN lt Section 1 2 9 Card Properties BRI SPID DN in the Programming Guide gt is displayed on the telephone of the other party as the CLIP number e Specify the registered Central Office calling number for correct operation of CLIP e 2 2 ISDN Originating Features F G Calling Line Identification Presentation CLIP e 4 3 19 Calling Line Identification Presentation CLIP U M 205 Line 206 Parameter DID TIE Digits to delete Default 0 Value Range 0 16 digits Description Function Specifies the number of digits to be deleted from the number received from the DID DID ISDN other PBX via TIE lines Reference e 1 5 Attended Features F G Direct Inward Dialing DID e 2 3 ISDN Attended Features F G Direct Inward Dialing DID e 3 1 TIE Line Features F G TIE Line Service Parameter DID TIE Number to be added Default Blank Value Range Max 8 digits consisting of 0 9 Description Function Specifies the number 1 to 8 digits to be added to the number received from the DID DID ISDN other PBX via TIE lines Reference e 1 5 Attended Features F G Direct Inward Dialing DID e 2 3 ISDN Attended Features F G Direct Inward Dialing DID e 3 1 TIE Line Features F G TIE Line Service Parameter Digit to receive DID Default 4 DID T1 DID
165. ice card is lit Reference None 1 2 2 Card Properties HLC SLC OPX SLC M Used to set the parameters for the following extension cards HLC SLC OPX SLC M Card Properties 206 HLG 16 96 ms E Break Detection Flash Detection Yes C No OK Cancel Help Programming Guide 13 Configuration Parameter Break Detection Default 16 96 ms Value Range 1 16 96 ms 2 16 136 ms Description Function Specifies the Pulse Break Detection length Dialed digits from a dial pulse type SLT are transmitted to the system by making and breaking a loop current thereby interrupting loop current Duration time required to detect the number of breaks may vary depending on the type of SLT connected Reference None Parameter Flash Detection Default Yes Value Range 1 Yes 2 No Description Function Activates or deactivates the detection of Flash signal transmitted from an SLT This determines the treatment of the call after an SLT user flashes the switchhook If set to Yes the system will place the call on consultation hold Therefore flash detection is enabled If set to No the system will disconnect the call In other words flash detection is disabled Reference None 1 2 3 Card Properties DHLC ESLC DLC 14 Used to set the parameters for the following extension cards DHLC ESLC DLC Card Properties 101 DHLO r Off hook Time iso ms Flash Detectio
166. ifies whether the extension can monitor through the corresponding DSS buttons the Login Logout status of UCD Group members or not Reference 1 3 System Features F G Extension Group e 1 5 Attended Features F G Uniform Call Distribution UCD 4 3 81 UCD Monitor Mode U M 176 Programming Guide Group Parameter UCD Setting UCD Call Waiting Default Enable Value Range 1 Disable 2 Enable Description Function This feature is different from regular Call Waiting This feature if enabled allows UCD group members to hear a Call Waiting tone when an inside outside call arrives but all the extensions in the UCD Group are busy Notes e To use this feature this setting must be set to enable e In addition each extension must enable regular Call Waiting Reference e 1 3 System Features F G Extension Group e 1 5 Attended Features F G Uniform Call Distribution UCD Parameter Operator Setting Call Priority Default CO Call 1 Intercept Routing 2 Recall 3 Extension Call 4 Value Range Priority 1 4 Description Function Specifies the answering priority of incoming calls to the Operator Group by a type of call when more than one call is ringing at an Operator extension Assignable only when Operator is specified in Group Type programming Notes e If all extensions in the Operator group are busy incoming calls directed to the group will be put in the waiting queue in order of preced
167. igital Trunk Details I M Parameter Signaling Bit Monitor Mode Default Mode 3 Value Range 1 Mode 1 2 Mode 2 3 Mode 3 Description Function Specifies the signaling bit to be monitored using the LED on the T1 card 1 Mode 1 LED SYNC ERROR RAI AIS SYNC TR A TR B TR C TR D bit 2 Mode 2 LED SYNC ERROR RAI AIS SYNC RX A RX B RX C RX D bit 3 Mode 3 LED SYNC ERROR RAI AIS SYNC TR A TR B RX A RX B bit Note e This setting is valid when the LPR software version of the T1 card is Y311D or later Reference e 4 7 Digital Trunk Details I M Parameter Software Information Default Display only Value Range Description Function Displays the ROM version of the T1 card software and ROM checksum Reference e 4 6 Digital Trunk Error Report I M Programming Guide e 4 7 Digital Trunk Details I M 27 Configuration 28 Parameter Inter digit Pause Default 830 ms Value Range 1 630 ms 2 830 ms 3 1030 ms Description Function Used to distinguish between pulse signals To meet the requirements of other PBX or Central Office select the appropriate value that represents the delay between dial pulses This setting is only required when using dial pulse trunks Reference e 1 3 System Features F G T1 Carrier Parameter Flash Detection Default No Value Range 1 Yes 2 No Description Function Activates or deactivates the detection of Flash signal transmitted from other PBX which is connect
168. ine U M Programming Guide 93 System 94 Parameter 48 Absent Message Set Cancel Default 750 Value Range 1 4 digits consisting of 0 9 X or Description Function Specifies the feature number for setting canceling Absent Message feature Reference e 4 3 1 Absent Message Capability U M Parameter 49 Timed Reminder Confirm Set Cancel Default 761 Value Range 1 4 digits consisting of 0 9 X or Description Function Specifies the feature number for confirming setting canceling Timed Reminder feature Reference e 4 3 74 Timed Reminder Wake Up Call U M Parameter 50 Station Lock Set Cancel Default 762 Value Range 1 4 digits consisting of 0 9 or Description Function Specifies the feature number for setting canceling Electronic Station Lockout feature Reference e 4 3 30 Electronic Station Lockout U M Parameter 51 Night Mode Set Cancel Default 78 Value Range 1 4 digits consisting of 0 9 or Description Function Specifies the feature number for turning on off the Night Service mode Reference e 4 3 48 Night Service On Off U M Parameter 52 Parallel Telephone Mode Default 39 Value Range 1 4 digits consisting of 0 9 X or Description Function Specifies the feature number for setting canceling Parallel Telephone mode Reference e 4 3 59 Paralleled Telephone Connection U M Programming Guide System Paramete
169. ing Program Default Dial All Blank 5 6 Account Code Program Default Tenant No 1 Entry No 0001 0020 Code Blank TRS Level None 5 7 Special Carrier Code Program Default Code Blank 5 8 Absent Message Program Default Message MSGI Will Return Soon MSG2 Gone Home MSG3 At Ext Extension No MSG4 Back at Hour Minute MSGS Out Until o Month Day MSG6 In a Meeting MSG7 9 Blank 5 9 DISA TIE User Code Program Default Code All Blank COS All 96 Programming Guide 379 Default Values 5 10 VPS Integration 5 10 1 VPS Integration 1 2 Program Default Integration Code Integration Code Ringback Tone 1 Integration Code Busy Tone 2 Integration Code Reorder Tone 3 Integration Code DND Tone 4 Integration Code Extension Answer 5 Integration Code Extension Disconnection 9 Integration Code Confirmation Tone 9 Integration Code FWD to VM Ringback Tone 6 Integration Code FWD to VM Busy Tone 7 Integration Code FWD to Extension Ringback 8 Tone Voice Mail Command Voice Mail Command Leave Message H Voice Mail Command Get Message H Voice Mail Command AA Service 8 Voice Mail Command VM Service 6 5 10 2 VPS Integration 2 2 Program Default DTME signal duration 80 ms Pause
170. ing digit transmission Reference None Parameter Pulse Feedback Tone Default Yes Value Range 1 Yes 2 No Description Function On outgoing CO calls the dialed number is toned out which informs the extension user that dialed number has been dialed out The dialed number is toned out by default Select No to turn off the pulse feedback tone Reference None Programming Guide 17 Configuration Parameter Inter digit Pause Default 830 ms Value Range 1 630 ms 2 830 ms 3 1030 ms Description Function Used to distinguish between pulse signals To meet the requirements of your Central Office select the appropriate value that represents the delay between dial pulses This setting is only required when using dial pulse trunks Reference None 1 2 5 Card Properties ELCOT Used to set the parameters for the ELCOT card Card Properties 203 ELCOT Collision Giana Vitter g E erect 18 Programming Guide Configuration Parameter First Dial Timer Default 1 0s Value Range 0 5 8 0 s in 0 5 s increments Description Function On outgoing CO calls the system waits at least 1 0 second after seizing the CO line before sending the dialing digits to the Central Office by default This allows the Central Office enough time to accept the dialing digits correctly Specifies the appropriate value depending on the requirements of your local Central Office Reference None
171. ing directory number as DN or FDN DSS Extension directory number which is in existence Phantom Floating directory number which is registered in 5 2 Phantom Extension screen SDN Primary directory number PDN of the DN mode extension VTR 2WAY REC TRN Extension directory number which is assigned as VPS E4025 PHANTOM key duplicated Two phantom keys cannot have the same phantom FDN Programming Guide 345 Programming Error Messages Error Message Error Code Description E4026 Please enter CO key number assigned to S CO G CO L CO or SDN key The CO key number which is assigned to Single CO Group CO Loop CO or SDN key should be entered when Prime Line CO is specified in Preferred Line Outgoing Incoming programming E4027 Doorphone destination duplicated Doorphone destinations extensions must be unique for Day mode settings and Night mode settings However an extension used for Day can be used for Night E4028 Converted digits exceed the limit Total number of converted digits should be less than 16 digits Please change Digits to delete or Number to be added or both E4029 Invalid directory number for G LOGIN LOGOUT key Only FDN of an Incoming Group can be assigned as the number of G LOGIN LOGOUT key E4030 Invalid directory number for G FWD key Only FDN of an Incoming Group can be assigned as the number of G FWD key E5001 Assign both n
172. intenance 10 3 External Modem 2 2 10 1 External Modem 2 2 Connection Message Max 80 Characters 1 EONNECT Disconnection Message Max 80 Characters 1 No CARRIER 10 1 External Modem 2 2 Parameter Connection Message 1 5 Default Message 1 CONNECT Others Blank Value Range Up to 80 characters consisting of 0 9 A Z a z or the following marks 3 lt gt amp Description Function Specifies Connection Message from Modem Reference e 1 3 System Features F G External Modem Control e 4 3 36 External Modem Control U M Parameter Disconnection Message 1 5 Default Message 1 NO CARRIER Others Blank Value Range Up to 80 characters consisting of 0 9 A Z a z or the following marks 3 lt gt 7 amp Description Function Specifies Disconnection Message from Modem Reference e 1 3 System Features F G External Modem Control e 4 3 36 External Modem Control U M Programming Guide 313 Maintenance 10 4 SMDR 10 4 1 SMDR 1 2 Station Message Detail Recording SMDR automatically records detailed information for outside calls 10 2 SMDR 1 2 ee ee ee g a Parameter SMDR Connection Default No Value Range 1 Yes 2 No Description Function Enables or disables SMDR Reference e 2 8 3 Personal Computer Printer I M 314 Programming Guide Maintenance
173. iption Function Specifies the extensions that ring when a visitor presses the doorphone button Up to 126 destination extensions per doorphone can be assigned in Day mode and Night mode respectively Destination extensions can unlock the door opener Reference e 4 3 29 Doorphone Call U M Programming Guide 241 Line 4 6 External Paging 242 Used to assign parameters for External Paging 4 5 External Paging seaman l any cane ae Parameter Pager No Default Display only Value Range 1 2 Description Function Displays the Pager No Reference e 2 8 1 External Pager Paging Equipment I M Parameter Tenant No Default 1 Value Range 1 8 Description Function Specifies the tenant to which the External Pager is assigned Required when Tenant Service is employed Reference e 1 3 System Features F G Tenant Service 2 2 Tenant P G Programming Guide Line Parameter FDN Default Blank Value Range 3 4 digits consisting of 0 9 Description Function Specifies the FDN Floating Directory Number for the External Pager Reference e 1 3 System Features F G Floating Station Parameter BGM Default No check Value Range 1 No check Disable 2 Check Enable Description Function Specifies whether BGM is sent or not when the External Pager is idle Whether sound actually comes out of External Pager or not is controlled by the
174. is specified in Group Type programming Note e When the other party calls the group by dialing the FDN of the group station hunting always works regardless of this setting Reference e 1 8 Ringing Features F G Programming Guide Station Hunting 173 Group 174 Parameter Calls to Empty Group Default Disable Value Range 1 Enable 2 Disable Description Function Allows for calls to empty all Logout Operator or UCD Groups to be queued If enabled calls will be queued to the group If disabled the extension will receive a reorder tone and the CO call will be transferred to the overflow destination immediately Assignable only when Operator or UCD is specified in Group Type programming Reference e 1 3 System Features F G Extension Group Operator Group e 1 5 Attended Features F G Uniform Call Distribution UCD Parameter UCD Setting Time Table No Default None Value Range None 1 32 Description Function Specifies the UCD Time Table 1 32 for the UCD Group Reference e 1 3 System Features F G Extension Group e 1 5 Attended Features F G Uniform Call Distribution UCD Programming Guide Group Parameter UCD Setting FWD No Answer Default Value Range Description Function Reference Disable 1 Disable 2 Enable Specifies the treatment of the call which is not answered by the extension in the UCD group within a specified period
175. its Truncate it Truncate means that the leading 20 digits are saved and the rest are deleted Wws8s001 PBX code must not exceed 3 digits Truncate it Truncate means that the leading 3 digits are saved and the rest are deleted W8002 TIE Leading dial must not exceed 3 digits Truncate it Truncate means that the leading 3 digits are saved and the rest are deleted W8003 TIE additional dial must not exceed 20 digits Truncate it Truncate means that the leading 20 digits are saved and the rest are deleted Ww9001 DID dial must not exceed 16 digits Truncate it Truncate means that the leading 16 digits are saved and the rest are deleted Ww9002 DID name must not exceed 10 characters Truncate it Truncate means that the leading 10 characters are saved and the rest are deleted W9003 Modem command must not exceed 80 characters Truncate it Truncate means that the leading 80 characters are saved and the rest are deleted w9004 Modem messages must not exceed 80 characters Truncate it Truncate means that the leading 80 characters are saved and the rest are deleted Ww9005 Base dial number must not exceed 15 digits Truncate it Truncate means that the leading 15 digits are saved and the rest are deleted W9006 Remote Information must not exceed 40 digits Truncate it Truncate means that the leading 40 digits are saved and the rest are deleted Programming Guide 351 Programming Error Messa
176. ke VPS port OUS Out of Service status before deleting the port E1036 Assign a port number before changing the port status The VPS port that does not have a port number cannot have its status changed Programming Guide 341 Programming Error Messages Error Message Error Code Description E1037 Cannot change the status of the port Cannot change the status of the SLT port because the PT port is activated as a Parallel Mode extension Please change the PT port status to XDP Mode and then press Apply E1038 You have exceeded the shelf limit of extension ports There is a limit of 192 extension ports per shelf when using PLC HLC SLC SLC M OPX DLC DHLC or ESLC cards Please de assign one card and try again E1039 You have exceeded the shelf limit of SLT ports There is a limit of 160 SLT ports per shelf when using HLC SLC SLC M DHLC or ESLC cards Please de assign one card and try again E1050 The slot next to PRI23 card must be empty Please remove and re assign the card that is installed next to a PRI23 card A PRI23 card must go into slot no 1 3 5 7 9 11 or 13 E1053 PRI card must be assigned to an odd numbered slot PRI card should be assigned to the odd numbered slot of basic shelf expansion shelf 1 and expansion shelf 2 E1054 The status of the card must be OUS Out of Service When you change the card properties of PRI23 or BRI card the status must be OUS
177. l Mode I M e 4 Utility I M Programming Guide Maintenance Parameter Password User Programming PT Default 1234 Value Range 4 7 digits consisting of 0 9 Description Function Specifies the password required for entering the User Programming mode by PT Reference e 1 2 System Administration F G User Programming with Proprietary Telephone e 3 User Programming U M Parameter Password Walking COS Default 1234 Value Range 4 7 digits consisting of 0 9 Description Function Specifies the password required for using the Walking COS feature Reference e 1 6 Originating Features F G Walking COS e 4 3 84 Walking COS U M Serial Interface Port PROG Port 1 Please refer to System Programming and Diagnosis with Personal Computer of Section 1 2 System Administration in the Features Guide Note e Generally speaking you should connect your Programming PC to Port 1 and your SMDR printer to Port 2 Parameter Serial Interface Port PROG Parity Default Display only Value Range None Description Function A parity code indicates what type of parity is used to detect an error in the string of bits composing a character Make an appropriate selection depending on the requirements of your printer or personal computer Note e Port 1 is fixed to None Reference None Programming Guide 325 Maintenance 326 Parameter Serial Interface Port PROG NL Co
178. l Proprietary Line Circuit card DPH Doorphone Circuit card ELCOT Enhanced Loop Start Central Office Trunk card ERMT Enhanced Remote Circuit card ESLC Enlarged Single Line Telephone Circuit with Message Waiting card GCOT Ground Start Central Office Trunk card HLC Hybrid Line Circuit card LCOT Loop Start Central Office Trunk card OPX Off Premise Extension card PLC Proprietary Line Circuit card PRI23 ISDN Primary Rate Access Interface card RMT Remote Circuit card SLC Single Line Telephone Circuit card SLC M Single Line Telephone Circuit with Message Waiting card T1 T1 Digital Trunk card Notes e To change the current Card Type to a new one delete the current setting first by selecting None and then assign a new Card Type e CPU Slot No 13 of the Basic Shelf is fixed to CPU Central Processing Unit card e TSW Slot No 14 of the Basic Shelf is fixed to TSW T Switch card e 1 4 Service Cards Description I M Programming Guide Configuration Parameter Status Default Value Range 1 INS 2 OUS 3 FAULT Description Function Used to set the status of the service cards 1 INS In Service The target service card is operating normally 2 OUS Out of Service Programming data for the target service card is entered but the target service card is not assigned to the system 3 FAULT The target service card is defective hardware In this case the LED indicator on the serv
179. lick e Are you sure is displayed 6 Point to Yes Y and click e Copying is displayed while the source data is being copied to the destination e Parameters of the destination Extension Lines are immediately effective when copying is finished 212 Programming Guide Line Parameter Card No Default Value Range XXX YYY XXX Card No 101 314 YYY Card Type Description Function Specifies the physical number of the extension card and its type which you are going to program Reference 1 2 Slot Assignment P G Parameter Port No Default 1 Value Range l n n 4 OPX 8 PLC HLC SLC SLC M 16 DLC DHLC ESLC 24 T1 OPX Description Function Specifies the extension port which you are going to program Note e Port Nos 17 32 will be displayed when DN and Group No for Ext No 2 are assigned in 1 5 VPS DPT Port Assignment Section 1 5 Reference 1 4 Extension Port Assignment P G Parameter DN Default Value Range 3 4 digits consisting of 0 9 Description Function Specifies the extension which you are going to program Reference 2 3 Numbering Plan P G Parameter Group No Default Display only Value Range 1 128 Description Function Displays the Extension Group to which the selected extension port is assigned Note e Default Group No for Ext 1001 is 128 Reference 3 3 Extension Group P G Programming Guide 213 Line 214
180. ling extension s display PT to show the reason of absence no answer 5 8 Absent Message z o o o w a e YW NY Message Max 16 Characters Wi Retum soon S Gone Home Cis AEM Backat Out Unti 9 ina meeting EN 5 8 Absent Message OK Anply_ Cancel Help Parameter Message Default MSGI Will Return Soon MSG2 Gone Home MSG3 At Ext Extension No MSG4 Back at W Hour Minute MSGS5 Out Until Month Day MSG6 In a Meeting MSG7 9 Blank Value Range Up to 16 characters consisting of 0 9 A Z a z or the following marks 3 lt gt amp Description Function Specifies Absent Messages Messages through 6 are programmed at the factory but can be changed Reference e 1 17 Display Features F G Programming Guide Absent Message Capability e 4 3 1 Absent Message Capability U M 2 3 Numbering Plan P G Absent Message Set Cancel 261 Features 5 9 DISA TIE User Code Used to program a list of up to 32 DISA TIE User Codes Each code is appended with a COS level a ee a cy a je je js fe je a a Co a a a f fe z A Ca A js fe je zi a cy a as a a a a Cy je a a Co je a cy je a Cy 5 9 DISAITIE User Code 262 Programming Guide Features Parameter Code Default V
181. ller ID COS No Primary 1 COS No Secondary 1 Preferred Line Outgoing Prime Line ICM PDN Preferred Line Outgoing Key No Blank Preferred Line Incoming Ringing Line Preferred Line Incoming Key No Blank Pickup Dialing Mode Disable Pickup Dialing Dial Display only LCS Setting Status Inactive LCS Setting Operation Mode Hands free LCS Setting Recording Mode Stop Rec LCS Setting LCS Password Blank Data Line Mode No Call Waiting Tone Type Tone 1 Call Pickup Deny Disable Language English Station Lock Password Blank ISDN Bearer Mode Automatic Programming Guide 375 Default Values Program Default JOG Dial Speed Normal CLIP Number Public Blank CLIP Number Private Blank Call Log Incoming Overwrite Mode Yes Call Log Incoming Lock Password Blank 4 3 2 Flexible CO Key Assignment Program Default Key Type CO 01 Loop CO Others Not Stored 4 3 3 Flexible PF Key Assignment for PT Program Default Key Type Not Stored 4 3 4 Extension Line 2 2 Program Default Intercept Destination Day Night Blank Call Forwarding No Answer Time 0 ring 4 4 DSS Console Program Default Paired Extension DSS Console 1 8 Port No Display only DSS Console 1 8 Model T7440 DSS Key PF Key Copy
182. lue Range 1 128 Description Function Specifies the Extension Group 1 128 to which the extension port is assigned Note e Group No of the first extension is assigned to 128 Reference e 1 3 System Features F G Extension Group 3 3 Extension Group P G Parameter Parallel XDP DHLC card Default Parallel Value Range 1 Parallel 2 XDP Description Function Specifies whether to enable or disable Paralleled Connection of PT and SLT or XDP eXtra Device Port Connection of DPT and SLT Reference e 1 1 System Expansion F G Programming Guide EXtra Device Port XDP e 1 3 System Features F G Paralleled Telephone 57 Configuration 58 Parameter Parallel XDP HLC card Default None Value Range 1 None 2 Parallel Description Function Specifies whether to enable or disable Paralleled Connection of PT and SLT Reference e 1 3 System Features F G Paralleled Telephone Parameter Status Default Value Range 1 INS 2 OUS 3 FAULT Description Function Specifies the operating status of the extension port 1 INS The extension port is In Service 2 OUS The extension port is Out of Service 3 FAULT The extension port is defective Reference None Parameter DN Refer Default Value Range Description Function Displays the list of DNs FDNs which are already assigned to the extensions system resources Reference None Programming Guide Configuration 1 5 VP
183. lue Range Up to 3 digits consisting of 0 9 or Description Function Specifies the Reorder Tone code Sent to the Voice Mail port when an invalid extension number is dialed or the call is inadvertently connected to another Voice Mail port also heard when no DTMF receiver is available to the Voice Mail extension Reference e 1 3 System Features F G Integration VPS Parameter Integration Code DND Tone Default 4 Value Range Up to 3 digits consisting of 0 9 or Description Function Specifies the DND Tone code Sent to the Voice Mail port when the extension dialed has set DND Do Not Disturb feature Reference e 1 3 System Features F G Integration VPS Parameter Integration Code Extension Answer Default gt Value Range Up to 3 digits consisting of 0 9 or Description Function Specifies the Extension Answer code Sent to the Voice Mail port when the extension dialed is answered Reference e 1 3 System Features F G Programming Guide Integration VPS 265 Features 266 Parameter Integration Code Extension Disconnection Default 9 Value Range Up to 3 digits consisting of 0 9 or Description Function Specifies the Extension Disconnection code Sent to the Voice Mail port when the caller disconnects The Central Office must set a CPC signal to the PBX line for this signal to work for CO calls Reference e 1 3 System Features F G Integration VPS Parameter Integra
184. ly parameters which are available to copy are shown in Copy Item field This depends on the Group Type assignment of the copy source Extension Group e Items marked with are copied 4 Point to Select All in the Destination Extension Group field and click e All displayed Extension Group Nos will be marked with v e You can also specify one or several Extension Groups as the copy destination by clicking it them directly 5 Point to Execute and click e Are you sure is displayed Programming Guide 169 Group 170 6 Point to Yes Y and click e Copying is displayed while the source data is being copied to the destination e Parameters of the destination Extension Groups are immediately effective when copying is finished Parameter Group No Default 1 Value Range 1 128 Description Function Specifies the Extension Group 1 128 which you are going to program Reference 1 3 System Features F G Extension Group Parameter Copy Default Value Range Description Function You can enter into Extension Group Copy screen by clicking this button Reference Parameter FDN Default Blank Value Range 3 4 digits consisting of 0 9 Description Function Specifies the FDN Floating Directory Number for the Extension Group Reference e 1 3 System Features F G Floating Station Parameter DN Refer Default Value
185. meter 5 5th Hundred Block Extension Default 14 Value Range 1 2 digits consisting of 0 9 Description Function Same as the Parameter 1 Reference e 1 3 System Features F G Flexible Numbering Parameter 6 6th Hundred Block Extension Default 20 Value Range 1 2 digits consisting of 0 9 Description Function Same as the Parameter 1 Reference e 1 3 System Features F G Programming Guide Flexible Numbering 85 System Parameter 7 7th Hundred Block Extension Default 21 Value Range 1 2 digits consisting of 0 9 Description Function Same as the Parameter 1 Reference e 1 3 System Features F G Flexible Numbering Parameter 8 8th Hundred Block Extension Default 22 Value Range 1 2 digits consisting of 0 9 Description Function Same as the Parameter 1 Reference e 1 3 System Features F G Flexible Numbering Parameter 9 9th Hundred Block Extension Default 23 Value Range 1 2 digits consisting of 0 9 Description Function Same as the Parameter 1 Reference e 1 3 System Features F G Flexible Numbering Parameter 10 10th Hundred Block Extension Default 24 Value Range 1 2 digits consisting of 0 9 Description Function Same as the Parameter 1 Reference e 1 3 System Features F G 86 Flexible Numbering Programming Guide System Parameter 11 16 11th Hundred Block Extension 16th Hundred Block Extension Default Blank Value Range 1 2 digits consisti
186. mming Guide 301 DID Dial 9 1 DID Dial Used to assign parameters required to utilize DID MDN service fz TD500 Maintena 9 DID Dial 302 Programming Guide DID Dial 9 2 DID Dial Registration 9 2 1 DID Dial Registration Used to specify several parameters for DID MDN service 9 1 DID Dial Registration Entry No a Automatic Registration eee Be Ue Ce arden O E Har a W Wo E ee 3 T eee i o 1 I eee E par u T E E par 0 W I E Tor o T I ee O E M a E Tor o I I 9 1 DID Dial Registration x OK Apply Cancel Help Parameter Entry No Default 0001 0010 Value Range 0001 1000 in 10 entries increments Description Function Specifies the entry number of DID MDN No which you are going to program Reference e 1 5 Attended Features F G Direct Inward Dialing DID e 2 3 ISDN Attended Features F G Direct Inward Dialing DID Multiple Directory Number MDN Ringing Service Parameter Automatic Registration Default Value Range Description Function You can enter into Automatic Registration screen Section 9 2 2 by clicking Automatic Registration on this screen Reference None Programming Guide 303 DID Dial 304 Parameter DID MDN No Default Blank Value Range Up to 16 digits consisting of 0 9 Description Function Specifies the DID MDN number which will be sent from the Central Office to th
187. n CNIP Calling Name Identification Restriction CNIR e 3 1 TIE Line Features F G TIE Line Service Programming Guide Configuration Parameter Timer Setting Default Value Range Description Function You can enter into ISDN Protocol Timer screen Section 1 2 11 Card Properties BRI PRI23 ISDN Protocol Timer by clicking imer Setting on this screen Reference None 1 2 11 Card Properties BRI PRI23 ISDN Protocol Timer ISDN protocol timers are defined by the ISDN user interface protocols For details please refer to the protocols of your ISDN provider ISDN Protocol Timer setting applies to both BRI and PRI23 cards ISDN Protocol Timer 701 0 300 s T02 0 60 s l s E 0 60 s jo gs A 0 60 s 245 m T05 0 300 s T06 0 60 TO 0 60 s fea s 35 s fi 0 s CO Qsig Master PRI only Qsig Slave PRI only T200 1 6 s T203 1 60s 4 1302 2 30 s r T303 2 12s 4 T304 0 255 s fi S fi 0 s 15 s fa s 20 s m T305 4 30 s 5 1306 0 255 s T310 10 300 s m T3D3 1 120 s m T3D9 0 255 s r Extension m T200 1 5 s gt T203 1 60s 4 T302 2 30s 4 r T303 2 12s 4 T304 0 255 s fi s fio s 15 S E s 20 T305 4 30 s p T306 0 255 s T310 10 300 s T3D3 1 120s gt T3D9 0 255 s 5 40 a 20 s 20 Cancel Help
188. n ONE TOUCH One Touch Dialing button MESSAGE Message Waiting button MESSAGE OTHER Another Extension Phantom Extension Message Waiting button FWD DND Call Forwarding Do Not Disturb button G FWD Group Call Forwarding button G LOGIN LOGOUT Group Login Logout button SAVE Saved Number Redial button ACCOUNT Account Code entry button CONF Conference button VTR Voice Mail Transfer button LOGIN LOGOUT Login Logout button 2WAY REC Two way Recording button 2WAY TRN Two way Transfer button LCS Live Call Screening button LCS CANCEL Live Call Screening Cancel button DAY NIGHT Day Night switching button ALARM Alarm button ANSWER Answer button RELEASE Release button TONE THROUGH Tone Through button ALERT Alert button e 2 2 3 Flexible Button Assignment U M e 3 2 5 005 Flexible CO Button Assignment U M Programming Guide Line 4 3 3 Flexible PF Key Assignment for PT Used to determine the usage of flexible PF buttons on PTs The following screen is displayed by clicking PF Key on 4 2 Extension Line screen Flexible PF Key EXT1001 lt Key Type Assignment gt The following Key Type Assignment screen is displayed by clicking Key Type Display button including eNot Stored for each PF Key on the above screen Flexible PF Key Bijil HENTE why Programming Guide 227 Line lt Additional Parameters Required by Key Type gt Depending on a Key Type a
189. n Function Reference 102 Programming Guide System 2 4 Class of Service COS 2 4 1 Class of Service COS 1 2 Used to assign the Class of Service COS parameters ass of Service 1 2 COS No fi Call FWD to CO MIE Trunk Group Setting TRS Level Account Code Mode p Switching DawNight Mode Day i z v Night i Optional C Enable Disable m Call from TRS Level 7 Extension p Time Limit of Outside Calls p Transfer to CO Enable C Disable C Yes No C Enable Disable Call FWD to COTIE gt _ OfF Hook Call Announcement p Call FWD Follow Me C Enable Disable OHCA Enable Disable Enable C Disable Busy Override DND Override Busy Override Deny C Enable Disable C Enable Disable Enable Disable Released Link Operation Digits Restriction in CO Talk gt Automatic Hold C Enable Disable Mode Unrestricted C Enable Disable SDNCGOS own Extension x 2 3 Class of Service 1 2 Apply Cancel Help Parameter COS No Default 1 Value Range 1 96 Description Function Specifies the COS 1 96 which you are going to program Reference e 1 3 System Features F G Class of Service COS 4 3 Extension Line P G Parameter Trunk Group Setting Default Value Range Description Function You can enter into Trunk Group Setting screen Section 2 4 2
190. n Presentation CLIP e 4 3 19 Calling Line Identification Presentation CLIP U M Programming Guide Line Parameter Call Log Incoming Overwrite Mode Default Yes Value Range 1 Yes 2 No Description Function Enables or disables Call Log Incoming Overwrite Mode If the Call Log is full 30 call records are already logged when a new Caller ID call comes in 1 Yes The new call record overwrites the oldest one in the Call Log 2 No The new call record is not logged Reference e 4 5 4 Call Log Incoming KX T7436 KX T7433 KX T7235 KX T7230 only U M Parameter Call Log Incoming Lock Password Default Blank Value Range Fixed to 3 digits consisting of 0 9 Description Function Specifies the Call Log Incoming Log Lock password The extension user can lock the call log display so that incoming call information is not shown on the display Note e The Manager and the Operators can cancel the Call Log Lock in case the extension user forgets the lock code Call Log Incoming Log Lock Reference e 4 5 5 Call Log Incoming Log Lock KX T7436 KX T7433 Programming Guide KX T7235 KX T7230 only U M 223 Line 4 3 2 Flexible CO Key Assignment Used to determine the usage of flexible CO buttons on PTs CO Key on 4 2 Extension Line screen The following screen is displayed by clicking c r l lt Key Type Assignment gt The following Key Type Assignment s
191. n Timer m Break Detection 16 96 ms 7 208 1016 ms x m Flash Detection Yes PEEB With dite No 200 ms hleaeh Range M LPR Version ior 6 ms OK Cancel Programming Guide Configuration Parameter Break Detection Default 16 96 ms Value Range 1 16 96 ms 2 16 136 ms Description Function Specifies the Pulse Break Detection length Dialed digits from a dial pulse type SLT are transmitted to the system by making and breaking a loop current thereby interrupting loop current Duration time required to detect the number of breaks may vary depending on the type of SLT connected Assignable for DHLC and ESLC only Reference None Parameter Flash Detection Default Yes Value Range 1 Yes 2 No Description Function Activates or deactivates the detection of Flash signal transmitted from an SLT This determines the treatment of the call after an SLT user flashes the switchhook If set to Yes the system will place the call on consultation hold Therefore flash detection is enabled If set to No the system will disconnect the call In other words flash detection is disabled Assignable for DHLC and ESLC only Reference None Parameter LPR Version Default Display only Value Range 0 15 Description Function Displays the LPR Software Version Reference 1 5 VPS DPT Port Assignment P G Programming Guide 15 Co
192. nabled or not Reference e 1 7 Dialing Features F G Programming Guide Pickup Dialing Hot Line e 4 3 62 Pickup Dialing Hot Line U M 217 Line 218 Parameter Pickup Dialing Dial Default Display only Value Range Up to 24 digits Description Function Displays the telephone number for Pickup Dialing feature The system automatically dials this number when an extension user goes off hook to make a call if Pickup Dialing is enabled Reference e 1 7 Dialing Features F G Pickup Dialing Hot Line e 4 3 62 Pickup Dialing Hot Line U M Parameter LCS Setting Status Default Inactive Value Range 1 Inactive 2 Active Description Function Specifies whether or not the extension can use the LCS Live Call Screening feature Reference e 1 9 Answering Features F G Live Call Screening LCS Parameter LCS Setting Operation Mode Default Hands free Value Range 1 Private 2 Hands free Description Function Assigns whether the voice message being recorded is monitored automatically through the built in speaker Hands free mode or an alert tone is sent Private mode while an incoming caller is leaving a message in the mailbox of the extension Reference e 1 9 Answering Features F G Live Call Screening LCS e 2 2 8 Live Call Screening LCS Mode Set U M Programming Guide Line Parameter LCS Setting Recording Mode Default Stop Rec Value Rang
193. ncoming call is redirected to a VM extension by IRNA feature or Overflow feature the system sends the digits of this mailbox number to the VPS When Mailbox No is set to Blank the system sends the FDN to the VPS Note e DN of VPS port cannot be assigned as a mailbox number and an Incoming Group destination Reference e 1 3 System Features F G Programming Guide Integration Voice Mail VM Service 185 Group Parameter FWD DND Mode Default Value Range Description Function Reference Enable 1 Disable 2 Enable Specifies whether to enable or disable the FWD DND Call Forwarding or Do Not Disturb feature assigned on all extensions in the Incoming Group Assignable only when Terminate Ring or UCD is specified in Group Type programming None Parameter Search Mode Default Value Range Description Function Reference 186 UCD 1 UCD 2 Sequential Specifies the search mode for extensions Assignable only when Operator Single or UCD is specified in Group Type programming 1 UCD The system selects the extension following the last one called as the destination extension 2 Sequential The system selects the extension assigned first in the Incoming Group as the destination extension e 1 3 System Features F G Incoming Group e 1 5 Attended Features F G Uniform Call Distribution UCD e 1 6 Originating Features F G
194. nction Specifies the CYCLIC Tone Detection Mode as Standard or Option 1 Standard Fixed Detection Mode 2 Option Flexible Detection Mode Note e Option is available when the LPR software version is greater than 1 Reference None 44 Programming Guide Configuration Parameter Decision Count Default 4 times Value Range 4 7 times Description Function Specifies the number of times the tone pattern must be received to establish reception of the CYCLIC tone This determines end of call Note e This parameter is valid when Option is selected in the CYCLIC Detection Mode menu Reference None Parameter Tone ON Time Min Default 144 0 ms Value Range 57 6 3600 ms in 14 4 ms increments Description Function Specifies the minimum time in milliseconds that the CYCLIC tone from the Central Office must be sent When the system detects the tone within the time range it is recognized as Tone ON Note e This parameter is valid when Option is selected in the CYCLIC Detection Mode menu Reference None Parameter Tone ON Time Max Default 244 8 ms Value Range 57 6 3600 ms in 14 4 ms increments Description Function Specifies the maximum time in milliseconds that the CYCLIC tone from the Central Office must be sent When the system detects the tone within the time range it is recognized as Tone ON Note e This parameter is valid when Option is selected in the CYCLIC Detection Mode menu
195. ne 4 1 Line 4 2 Trunk Line Program Default Card No Port No 1 Copy Group No Display only Name CO001 CO192 Incoming Type 1 DIL ELCOT GCOT LCOT T1 GCO T1 LCO card 2 DID DID T1 DID card 3 DID SDN BRI PRI23 card 4 TIE T1 TIE card Dial Type DTMF 80 ELCOT GCOT LCOT T1 DID card ISDN BRI PRI23 card Destination Day Night Lunch Break Day Night 1001 Lunch Break Blank Subscriber Blank DID TIE Digits to delete 0 DID TIE Number to be added Blank Digit to receive DID 4 DID T1 DID card 16 BRI PRI23 card Wink Signal Time out 1024 ms Start Signal Type Wink Answer Wait Timer None CPC Signal OUT Detection Enable DID card Disable ELCOT GCOT LCOT T1 GCO T1 LCO card CPC Signal OUT Detection Detection Time 400 ms CPC Signal IN Detection Enable DID ELCOT GCOT LCOT T1 GCO T1 LCO card CPC Signal IN Detection Detection Time 400 ms TIE Line TIE to CO Security Mode No TIE Line Sending TIE Caller ID No Caller ID Disable 374 Programming Guide Default Values 4 3 Extension Line 4 3 1 Extension Line 1 2 Program Default Card No Port No 1 DN Group No Display only Copy Name Blank Message Lamp No Mailbox No Same as the extension number CO Key PF Key Initial Display Selection Ca
196. ne is emitted every 5 seconds until the held call is retrieved or until the caller hangs up Note If 0 is specified Hold Recall does not occur Reference e 1 13 Audible Tone Features F G Programming Guide Hold Recall 113 System 114 Parameter Transfer Recall Time Default 12 rings Value Range 0 48 rings Description Function Specifies the number of rings before transfer recall occurs If a transferred call is not answered before the programmed number of rings the call returns to the extension user who originally transferred it or an Operator depending on the setting of 6 Transfer recall destination in Section 2 8 System Option Note e If O is specified Transfer Recall does not occur Reference None Parameter Pickup Dial Waiting Time Default ls Value Range 0 5 s Description Function Specifies the length of time in seconds that the system is to wait after an extension user goes off hook for making a call before the system automatically dials the pre assigned telephone number for Pickup Dialing Note e This waiting time gives the extension user an opportunity to dial another number before automatic dialing is performed Reference e 1 7 Dialing Features F G Pickup Dialing Hot Line e 4 3 62 Pickup Dialing Hot Line U M Programming Guide System Parameter Call Duration Count Start Time Default Os Value Range 0 60 s Description Function Specifies the le
197. nection parameters failed because file TD500 INI is damaged Please refer to the description of E0015 E0017 Failed Reading of remote connection parameters Reading of remote connection parameters failed because file TD500 INI is damaged Please refer to the description of E0015 E0018 There is not enough space on your hard disk or floppy to save the system data Download is incomplete because there is not enough space on your hard disk or floppy to save the system data E1001 You have exceeded the shelf limit of PT ports There is a limit of 128 PT ports per shelf when using PLC HLC DLC or DHLC cards Please de assign one card and try again E1002 You have exceeded the system limit of trunk ports There is a limit of 192 trunk ports per system when using LCOT GCOT T1 DID ELCOT BRI or PRI23 cards Please de assign one card and try again E1003 You have exceeded the system limit of extension ports There is a limit of 448 extension ports per system when using DLC PLC HLC SLC SLC M OPX DLC DHLC or ESLC cards Please de assign one card and try again E1004 You have exceeded the system limit of trunk extension ports There is a limit of 512 trunk extension ports per system using trunk and extension cards Please de assign one card and try again E1005 You have exceeded the system limit of DISA cards There is a limit of 8 DISA cards per system Programming Guide 339 Programming E
198. nfiguration Parameter Off hook Time Default 160 ms Value Range 8 512 ms in 8 ms increments Description Function Specifies the length of time in milliseconds that the system recognizes as an off hook signal sent from the local Central Office Assignable for DHLC and ESLC only Reference None Parameter Flash Detection Timer Default 208 1016 ms Value Range 1 208 1016 ms 2 80 1016 ms Description Function Specifies the time range in milliseconds that the system requires to recognize a switchhook flash Assignable for DHLC and ESLC only Reference None 1 2 4 Card Properties LCOT GCOT 16 Used to set the parameters for the following trunk cards LCOT GCOT Card Properties 208 LCOT BaSih titi Calera E Programming Guide Configuration Parameter First Dial Timer Default 1 0s Value Range 0 5 8 0 s in 0 5 s increments Description Function On outgoing CO calls the system waits at least 1 0 second after seizing the CO line before sending the dialing digits to the Central Office by default This allows the Central Office enough time to accept the dialing digits correctly Specifies the appropriate value depending on the requirements of your local Central Office Reference None Parameter Break Default 60 Value Range 1 60 2 67 Description Function Specifies the break for pulse digits This is the ratio between on hook and off hook signals dur
199. ng of 0 9 Description Function Same as the Parameter 1 Reference e 1 3 System Features F G Flexible Numbering Parameter 17 Operator Call Default 0 Value Range 1 4 digits consisting of 0 9 x or Description Function Specifies the feature number for calling the Operator FDN for each Operator Group can also be used for this purpose Reference e 4 3 53 Operator Call U M Parameter 18 Local CO Line Access ARS Default 9 Value Range 1 4 digits consisting of 0 9 or Description Function Specifies the feature number for making an outside call by ARS Automatic Route Selection or Trunk Access Idle Reference e 4 3 54 Outward Dialing Trunk Access U M Parameter 19 Trunk Group Access Default 8 Value Range 1 4 digits consisting of 0 9 x or Description Function Specifies the feature number for making an outside call by specifying a Trunk Group 01 48 Reference e 4 3 54 Outward Dialing Trunk Access U M Programming Guide 87 System 88 Parameter 20 Speed Dialing System Default i Value Range 1 4 digits consisting of 0 9 or Description Function Specifies the feature number for making a call using a System Speed Dialing number Reference e 4 3 73 System Speed Dialing U M Parameter 21 Speed Dialing Station Default 3 Value Range 1 4 digits consisting of 0 9 or Description Function Specifies the feature number for making a call using a Station
200. nge 1 Disconnect 2 Ignore Description Function Specifies the treatment of the call when the Status Message provided by ISDN doesn t match the actual status of the call Reference None Parameter Line Mode L1 Mode Default Display only Value Range Permanent fixed Description Function Displays the active mode of the Layer 1 on an ISDN line basis Reference None Parameter Line Mode L2 Mode Default Display only Value Range Permanent fixed Description Function Displays the active mode of the Layer 2 on an ISDN line basis Reference None Parameter Line Mode Access Mode Default Display only Value Range P MP fixed Description Function Displays the configuration on an ISDN line basis Reference None Programming Guide 31 Configuration 32 Parameter Line Mode TEI Default Display only Value Range Automatic fixed Description Function Displays the TEI Terminal Endpoint Identifier mode on an ISDN line basis Reference None Parameter Line Mode TE Power Default No check Disable Value Range 1 Check Enable 2 No check Disable Description Function Specifies whether the system supplies an electric power to TE or not Reference None Parameter Line Mode SPID DN Default Value Range Description Function You can enter into SPID DN screen Section 1 2 9 Card Properties BRI SPID DN by clicking SPID DN on this screen Reference None Pa
201. nge Same as Day Description Function Specifies the end time for Break Service Reference 1 3 System Features F G Night Service Programming Guide System Parameter Music on Hold Source Default MUS1 Value Range 1 None 2 MUSI 3 MUS2 4 Tone Description Function Specifies the Music Source port to be used for Music on Hold Reference e 1 3 System Features F G Music on Hold e 2 8 2 External Music Source I M Parameter BGM Source Default MUS1 Value Range 1 None 2 MUSI 3 MUS2 Description Function Specifies the Music Source port to be used for BGM Reference e 2 8 2 External Music Source I M Parameter Manager Extension DN Default Blank Value Range 3 4 digits consisting of 0 9 Description Function Specifies the extension for the Manager Reference e 1 3 System Features F G Programming Guide Manager Extension e 4 4 Operator Manager Service Features U M 81 System 82 Parameter System Speed Dialing Entries Max Default Tenant No 1 1000 Tenant No 2 1000 Tenant Nos 3 8 0 Value Range 0 1000 in 20 codes increments Description Function Specifies the maximum number of Speed Dialing codes available for each tenant Note e Up to 2000 Speed Dialing codes can be shared among tenants under the restriction of up to 1000 codes per tenant Reference 5 2 System Speed Dialing P G Parameter Automatic Route Selection Default No check V
202. ngth of time in seconds the system is to wait after sending all dialing digits to the Central Office before starting the call duration count Note e The elapsed time of the call duration is shown on a display PT Reference e 1 3 System Features F G Station Message Detail Recording SMDR Parameter First Digit Time Default 10s Value Range 5 120 s Description Function Specifies the maximum time allowed between the start of an outside dial tone and the first digit dialed on an outgoing call Reference None Parameter Inter digit Time Default 5s Value Range 1 30 s Description Function Specifies the maximum time allowed between each digit on an outgoing call Note e This timer applies to the call until the Toll Restriction check is completed Reference None Programming Guide 115 System Parameter Call Forwarding No Answer Time Default 3 rings Value Range 1 12 rings Description Function Specifies the number of rings before the Call Forwarding No Answer feature is activated If a call is not answered before the programmed number of rings the call is redirected to the pre assigned extension Note e This timer is also used for Intercept Routing If an incoming DISA call to the Intercept Routing destination is not answered before this timer expires the call will be disconnected Reference e 1 11 Transferring Features F G Call Forwarding e 4 3 9 Call Forwarding U M 4 3 Extension Line P G Parameter Exte
203. nk group is assigned This setting is required when Tenant Service is employed Reference e 1 3 System Features F G Programming Guide Tenant Service 2 2 Tenant P G 157 Group Parameter Flash Time Default Value Range Description Function Reference 600 ms None 80 ms 300 ms 600 ms 900 ms 1200 ms See E T Specifies the length of flash time Notes e When you need finer resolution assign this to 80 ms and use Flash Time parameter in Section 1 2 5 Card Properties ELCOT e You must use Flash Time parameter in Section 1 2 5 Card Properties ELCOT when your Central Office requires a Flash Time not listed here None Parameter Disconnecting Time Default Value Range Description Function Reference 158 1 558 0 5 s 1 558 2 08 4 0s 12 0s a aa Specifies the maximum time in seconds the system is to wait after releasing the trunk line before getting it again Note e This allows the Central Office an opportunity to release its resources before another trunk call is placed from the PBX None Programming Guide Group Parameter Pause Time Default 15s Value Range 1 1 5s 2 2 5 s 3 3 5 s 4 455 Description Function Specifies the length of pause time dialing delay The programmed pause time is automatically inserted after a line access code or a host PBX access code or manually inserted when the PAUSE but
204. nnot assign more than 8 SDN keys for one PDN key Up to eight SDN keys per PDN key can be assigned on eight different PTs respectively E4015 Invalid directory number for SDN key Only DN of an extension can be assigned to SDN key number E4016 SDN key duplicated Two SDN keys cannot have the same extension number E4017 Cannot assign SDN key to its own directory number Please assign SDN to a directory number other than its own E4018 Dial registration resource exhausted Cannot register any more because the system resource that stores extension mailbox numbers voice mail access codes and One Touch Dialing numbers has been exhausted E4020 Invalid directory number for doorphone call destination Only DN of an extension can be assigned as a doorphone call destination E4021 Secret dial S must be placed at the beginning and end of desired secret numbers Cannot assign Secret Dialing S that is registered in One Touch dialing without being even number E4022 Cannot assign PDN key as Prime Line CO Please assign key number except for PDN key when the outgoing or incoming preferred line is set to Prime Line CO E4023 Illegal trunk group number Please assign the trunk group number 1 48 on Group CO key E4024 DN or FDN must be entered to assign the type of key You must enter the DN or FDN when you assign key type DSS Phantom SDN VTR 2WAY REC and 2WAY TRN Each key needs follow
205. nsion to CO Line Call Duration Time Default 10 min Value Range 1 64 min Description Function Specifies the maximum time allowed for a call with an outside party This time limit can apply to outgoing CO calls only or both outgoing and incoming CO calls This is determined by 5 Limited call duration setting in Section 2 8 System Option Note e This timer applies to the extension user who is restricted by Time Limit of Outside Calls setting in Section 2 4 Class of Service COS Reference None 116 Programming Guide System Parameter CO to CO Line Call Duration Time Default 10 min Value Range 1 64 min Description Function Specifies the maximum time allowed for a call between two outside parties CO to CO line call If this timer expires during a CO to CO line call it will be disconnected Reference e 1 5 Attended Features F G Direct Inward System Access DISA e 1 11 Transferring Features F G Call Forwarding Call Transfer Parameter Door Opener Time Default 5s Value Range 0 10s Description Function Specifies the door opening duration Reference e 1 3 System Features F G Programming Guide Door Opener e 4 3 29 Doorphone Call U M 117 System 2 5 2 System Timer 2 2 Used to assign various system timers em Timer 2 2 p p o peo Parameter Timed Reminder Ringing Time Default 30s Value Range 30 240 s De
206. nterface per channel 1 Undefined Not assigned 2 LCO Loop Start Central Office 3 GCO Ground Start Central Office 4 DID Direct Inward Dialing 5 TIE E amp M TIE Line 6 OPX Off Premise Extension Reference e 1 3 System Features F G T1 Carrier Parameter DN Default Blank Value Range 3 4 digits consisting of 0 9 Description Function Specifies the extension for the T1 port Assignable only when OPX is specified in Channel Type setting Reference 2 3 Numbering Plan P G 66 Programming Guide Configuration Parameter Group No Default Blank Value Range 1 48 or 1 128 Description Function Channel Type LCO GCO DID TIE E amp M Specifies the Trunk Group 1 48 to which the T1 port is assigned Channel Type OPX Specifies the Extension Group 1 128 to which the T1 port is assigned Reference e 1 3 System Features F G Extension Group Trunk Group 3 2 Trunk Group P G 3 3 Extension Group P G Parameter Status Default Value Range 1 INS 2 OUS 3 FAULT Description Function Specifies the operating status of the T1 port 1 INS The T1 port is In Service 2 OUS The T1 port is Out of Service 3 FAULT The T1 port is defective hardware In this case the LED indicator on the T1 card will light Reference None Parameter DN Refer Default Value Range Description Function Displays the list of DNs FDNs which are already assigned to the extensions system re
207. nth Please refer to Default values of summer time Start Day Please refer to Default values of summer time End Day Please refer to Default values of summer time Start Year Please refer to Default values of summer time 11 Programming Error Messages 11 1 Error Messages EXXXX 11 2 Warning Messages WXXXX 11 3 Information Message IXXXX Programming Guide 387 Panasonic Telephone Systems A oiceSonic See More Panasonic Panasonic Manuals www voicesonic com Phone 877 289 2829 Copyright This manual is copyrighted by Panasonic Communications Co Ltd PCC You may print out this manual solely for internal use with this model Except above you may not reproduce this manual in any form in whole or part without the prior written consent of PCC and its licensee 2000 Panasonic Communications Co Ltd All Rights Reserved Printed in Japan PSQX1889SA KKO899MN6113 M
208. o be connected to the extension port 1 TEL Select this option when you connect a telephone set to the extension port 2 DSS Select this option when you connect a DSS Console to the extension port 3 VPS DPT Select this option when a port of Panasonic Voice Processing System one that supports DPT Integration is connected to the extension port Notes e DPT integration except TVS300 does not function unless the VPS is connected to a DLC or DHLC card whose LPR Version ROM Version is 1 or later e DPT integration TVS300 only does not function unless it is connected to a DLC or DHLC card whose LPR Version ROM Version is 2 or later e You can confirm the LPR Version ROM Version of the DLC and the DHLC card in Card Properties Screen for each card Please refer to LPR Version parameter in Section 1 2 3 Card Properties DHLC ESLC DLC e There is a limit of 8 VPS DPT ports per card e There is a limit of 16 VPS DPT ports per shelf Reference 1 5 VPS DPT Port Assignment P G 4 3 Extension Line P G 4 4 DSS Console P G Programming Guide 55 Configuration 56 Parameter Tel Type Default Value Range Description Function Reference Display only Please refer to Description Function Displays the model number of telephone set which is currently connected to the extension port lt Telephone type list gt Unknown Not connected or Single Line Telephone
209. of time Call Forwarding No Answer Time 1 Disable The call continues to ring the current destination extension 2 Enable The system transfers the call to an idle extension in the group e 1 3 System Features F G Extension Group e 1 5 Attended Features F G Uniform Call Distribution UCD Parameter UCD Setting Auto LOGOUT Mode Default Value Range Description Function Reference Programming Guide Disable 1 Disable 2 1 10 times Specifies the treatment of extensions ina UCD group who do not cannot answer the call A member extension may be logged out automatically if it does not answer the call for pre determined times 1 10 consecutively If Disable is specified this setting does not function e 1 3 System Features F G Extension Group e 1 5 Attended Features F G Uniform Call Distribution UCD 175 Group Parameter UCD Setting Supervisor Extension Default Blank Value Range 3 4 digits consisting of 0 9 Description Function Specifies the Supervisor Extension per UCD Group The extension specified as the Supervisor Extension can monitor the number of waiting calls calls placed in the waiting queue Reference e 1 3 System Features F G Extension Group e 1 5 Attended Features F G Uniform Call Distribution UCD Parameter UCD Setting LOGIN Monitor Default Disable Value Range 1 Disable 2 Enable Description Function Spec
210. on Default No check Value Range 1 No check Disable 2 Check Enable Description Function Used to disconnect the trunk line when the system detects a continuous signal during a CO to CO line call by DISA or AGC Reference e 1 5 Attended Features F G Direct Inward System Access DISA Parameter Silence Detection Default Check Value Range 1 No check Disable 2 Check Enable Description Function Used to disconnect the trunk line when the system detects no signal during a CO to CO line call by DISA or AGC Reference e 1 5 Attended Features F G Programming Guide Direct Inward System Access DISA 163 Group 3 2 2 Trunk Group 2 2 Used to assign parameters for each trunk group Up to 48 trunk groups can be created in the system Parameter ISDN Progress Tone Mode Default Automatic Value Range 1 Automatic 2 Network 3 PBX Description Function Selects the way to supply the progress tone to an extension when the extension user makes an outgoing call via ISDN 1 Automatic If the network provides a progress tone the system sends the network progress tone to the caller If not the system sends the PBX progress tone 2 Network The system sends the network progress tone to the caller under all conditions 3 PBX The system sends the PBX progress tone to the caller under all conditions Reference None 164 Programming Guide Group Parameter IRNA for TIE Line D
211. on Value Range 1 Do not send dials entered during conversation 2 Send dials entered during conversation Description Function This parameter is available only when redialing using ISDN This option determines how redialing is done If Do not send dials entered during conversation is selected DTMF tones entered during a conversation are not redialed If Send dials entered during conversation is selected DTMF tones entered during a conversation are redialed Reference None Parameter 57 VPS Auto Configuration Mode Default Create mailboxes only for the tenant which has VPS ports Value Range 1 Create mailboxes only for the tenant which has VPS ports 2 Create mailboxes of all tenants Description Function Selects the auto configuration mode for TVS system Reference 1 3 System Features F G Automatic Configuration 144 Programming Guide System Parameter 58 Release of BRI PRI line while talking when DISCONNECT signal is received Default Don t Release Value Range 1 Release 2 Don t Release Description Function Specifies whether or not the system releases the ISDN BRI PRI line when receiving the line disconnection message from the ISDN Network while the line is in talking Reference None Parameter 59 ARS Call Timeout Mode Default Local Access Value Range 1 Local Access 2 Disconnect Description Function Specifies the outgoing operation mode when the inter digit timer ex
212. on Function Specifies the identification code of the calling party Caller ID code to utilize Caller ID Service Reference e 4 5 4 Call Log Incoming KX T7436 KX T7433 KX T7235 KX T7230 only U M Programming Guide Features 5 13 UCD Time Table If all extensions in a UCD group are busy the incoming CO calls will be handled by the UCD Time Table procedure Up to 32 UCD Time Tables max 16 steps for each can be assigned ersucoTmerae ie ok dow Cancel He Parameter Table No Default 1 Value Range 1 32 Description Function Specifies the UCD Time Table which you are going to program Reference 3 3 Extension Group P G 3 5 Incoming Group P G Programming Guide 279 Features 280 Parameter Command Sequence 1 16 Default Value Range Description Function Reference None None S1 S8 1T 4T TR RET OFF The following commands are provided to construct a UCD Time Table procedure lt Commands list and their functions gt 1 None Skips to the next sequence 2 S1 S8 OGM 1 8 is sent to the caller if available If not wait until OGM 1 8 becomes available 3 1T 4T Callers are put in the waiting queue for N 1 4 x 8 seconds while hearing the ringback tone or music on hold TR Transfers a call to the Overflow destination a A RET Returns to the first step of the sequence nN OFF Disconnects th
213. on which will be alerted by the system if there is an extension user who did not respond to the Timed Reminder ringing or Wake Up Call Reference e 1 8 Ringing Features F G Timed Reminder Wake Up Call Timed Reminder Remote Wake Up Call 4 4 11 Timed Reminder Remote Wake Up Call U M e 4 3 74 Timed Reminder Wake Up Call U M Parameter DAY NIGHT Switching Mode Default Manual Value Range 1 Manual 2 Auto Description Function Specifies the Day Night Lunch Break switching mode Manual or Auto 1 Manual The extension allowed by COS Class of Service programming the Manager or the Operators can switch Day Night Lunch Break mode at any time desired by dialing the feature number or pressing the Day Night button 2 Auto The system automatically switches the Day Night Lunch Break mode each day at the time programmed in Auto Start Time Reference e 4 3 48 Night Service On Off U M 78 Programming Guide System Parameter Inter tenant Calling 1 8 Default No check Value Range 1 No check Disallowed 2 Check Allowed Description Function Specifies other tenant numbers to which extensions in this tenant can make a call If no tenant numbers are checked in this field extension users within this tenant cannot make a call to extensions in other tenants Making calls from one tenant to another is not allowed by default Reference e 1 3 System Features F G Tenant Servi
214. one 33 None gt None gt N 02 None 10 None 18 None 26 None m 34 None None 03 None 11 None 19 None 27 None 35 None None oo 04 None 12 None 20 None 28 None 36 None p None 05 jNone 13 None 21 None 29 None 37 None None 06 jNone 14 None 22 None 30 None 38 None a None 07 jNone 15 None 23 None 31 None 39 None gt ber None UHEEVENL TT nuguuuuy uuuuuNE ouuuuNE nuguuuuy 08 None 16 None 24 None 32 None 40 None oo None 2 5 Local Hunt Sequence 7 OK Apply Cancel Help Parameter Trunk Group No Default 01 1 Others None Value Range None 1 48 Description Function Specifies the trunk group 1 48 in hunting order Notes e Local Hunt Sequence works only when ARS Automatic Route Selection mode is turned off e The sequence can be used by any extension user in the system regardless of the tenant but trunk groups will be skipped if they do not belong to the same tenant as the extension user Reference e 1 6 Originating Features F G Trunk Access e 4 3 54 Outward Dialing Trunk Access U M Programming Guide 123 System 2 7 Trunk to Trunk Restriction Used to allow or restrict the trunk to trunk relay function routing a trunk call from one Trunk Group to another on a trunk group
215. onnect 2 Ignore Description Function Specifies the treatment of the call when the Status Message provided by ISDN doesn t match the actual status of the call Reference None Parameter DTMF Signal Duration Default 80 ms Value Range 1 80 ms 2 160 ms Description Function Specifies the duration of the DTMF signals sent to ISDN Reference None Parameter DTMF Signal Inter digit Pause Default 112 ms Value Range 64 240 ms in 16 ms increments Description Function Specifies DTMF inter digit pause time Reference None Programming Guide 35 Configuration 36 Parameter Line Coding Default B8ZS Value Range 1 B8ZS 2 AMI Description Function Specifies the PCM Pulse Code Modulation Line Coding type for the PRI23 card Reference None Parameter Frame Sequence Default Extended Superframe ESF Value Range 1 4 Frame Multiframe F4 2 12 Frame Multiframe F12 3 Extended Superframe ESF 4 Remote Switch F72 SLC96 Description Function Specifies the Frame Sequence type for the PRI23 card Reference None Parameter Software Information Default Display only Value Range Description Function Displays the ROM version of the PRI23 card software and ROM checksum Reference e 4 6 Digital Trunk Error Report I M e 4 7 Digital Trunk Details I M e 2 1 ISDN Features F G Integrated Services Digital Network ISDN Extension e 2 2 ISDN Originating Features F G Calling Name Identification Presentatio
216. pires while making an outgoing call with ARS If you select Local Access and the timer expires the system will select a CO line on a Local CO Line Access basis and return CO dial tone Reference e 1 6 Originating Features F G Automatic Route Selection ARS Parameter 60 Empty Group Default Allow Value Range 1 Allow 2 Disallow Description Function Determines whether an Extension Group or an Incoming Group can be empty All members logged out If it is set to Disallow the group cannot be empty At least one extension must be logged in Reference e 1 3 System Features F G Programming Guide Extension Group Incoming Group e 1 5 Attended Features F G Uniform Call Distribution UCD e 1 8 Ringing Features F G Log In Log Out e 4 3 45 Log In Log Out U M 145 System 2 8 6 System Option 6 146 Used to assign system option parameters No 61 No 67 2 7 System Option 6 r 61 Auto Answer with held call 67 Sending DID Number to YPS Disable C Enable Disable C Enable 63 VM Trunk Service for DID Disable Enable 64 CNIP Service Disable C Enable 65 Alert Ringing Disable C Enable 2 7 System Option 6 x Apply Cancel Help Parameter 61 Auto Answer with held call Default Disable Value Range 1 Disable 2 Enable Description Function Specifies whether the PT user automatically answers
217. plan and time schedule Up to 48 Routing Plan entries can be programmed in the system 7 3 ARS Routine Plan Plan No x Time A Trunk Group No Modification Table No Time B Trunk Group No Modification Table No Time C Trunk Group No Modification Table No Time D Trunk Group No Modification Table No ae a 1 2 3 4 5 6 4 gt 7 8 7 3 Routing Plan x Parameter Plan No Default 1 Value Range 1 48 Description Function Specifies the Routing Plan Table 1 48 which you are going to program Reference e 1 6 Originating Features F G Automatic Route Selection ARS Parameter Time A B C D Trunk Group No Default None Value Range None 1 48 Description Function Specifies the TRG Trunk Group 1 48 which is used for routing the call Up to 16 trunk groups can be entered Reference e 1 6 Originating Features F G Automatic Route Selection ARS Programming Guide ARS Automatic Route Selection Parameter Time A B C D Modification Table No Default None Value Range None 1 48 Description Function Specifies the MOD Modified Digit table 1 48 which is used to modify the user dialed number so that it matches the requirements of the carrier Reference e 1 6 Originating Features F G Programming Guide Automatic Route Selection ARS 293 ARS Automatic Route Selection 7 5 Digits Modification
218. prolong operation setting in Section 2 8 System Option the call duration can be prolonged 10 times or without limit Reference e 1 5 Attended Features F G Programming Guide Direct Inward System Access DISA 119 System 120 Parameter DISA Delayed Answer Time Default 1 ring Value Range 0 6 rings Description Function Specifies the number of rings the system is to wait after receiving a DISA call before answering it Note e A DISA call is answered after a ringback tone is returned to the caller after the DISA Delayed Answer Time expires The DISA caller can dial while hearing the OGM message Reference e 1 5 Attended Features F G Direct Inward System Access DISA Parameter Timed Reminder Arrive Count Default 3 times Value Range 1 5 times Description Function Specifies the number of times 1 5 Timed Reminder Remote Timed Reminder Wake Up Call is repeated until the destination extension answers it Reference 1 8 Ringing Features F G Timed Reminder Wake Up Call Timed Reminder Remote Wake Up Call e 4 3 74 Timed Reminder Wake Up Call U M e 4 4 11 Timed Reminder Remote Wake Up Call U M Parameter DISA Automated Attendant Time Default ls Value Range 1 5 s Description Function Specifies the length of time in seconds the system is to wait before recognizing the first digit as a DISA Automated Attendant number If this timer expires before the second digit is dial
219. ption Function Specifies the base number for automatic registration Additional numbers are appended to the end of this number Reference None Programming Guide 307 DID Dial 308 Parameter Additional Number Number of Registrations Default 10 entries Value Range 10 100 entries in 10 entries increments Description Function Specifies the number of DID MDN entries to be registered automatically Reference None Parameter Additional Number Number of Digits Default 2 digits 00 99 Value Range 1 16 digits Description Function Specifies the number of digits to be added to the end of the Base Number Reference None Parameter Beginning Entry No Default 1 Entry No 1 Value Range 1 991 Description Function Specifies the first entry number for automatic registration This number corresponds to the DID MDN No in 9 1 DID Dial Registration screen Reference None Programming Guide Maintenance Section 10 Maintenance Programming Guide 309 Maintenance 10 1 Maintenance Used to assign parameters for system maintenance i T0500 Maintenanc Programming 310 Programming Guide Maintenance 10 2 External Modem 1 2 The system supports an external modem plugged into the RS 232C port for remote system administration 10 1 External Modem 1 2 AT amp FOQOEOV1 SO 1X0 amp D0 ior eemawoem e OK dow Caneel He
220. r summer time Reference None Parameter Start Month Default Please refer to Default values of summer time Value Range Jan Dec Description Function Selects the month by clicking the small triangle Reference None 334 Programming Guide Maintenance Parameter End Month Default Please refer to Default values of summer time Value Range Jan Dec Description Function Selects the month by clicking the small triangle Reference None Parameter Start Day Default Please refer to Default values of summer time Value Range 01 31 Description Function Specifies the date in two digits by entering the value directly Reference None Parameter End Day Default Please refer to Default values of summer time Value Range 01 31 Description Function Specifies the date in two digits by entering the value directly Reference None Parameter Start Year Default Please refer to Default values of summer time Value Range 00 99 Description Function Specifies the last two digits of the year by entering the value directly Reference None Programming Guide 335 Maintenance 336 Programming Guide Programming Error Messages Section I Programming Error Messages Programming Guide 337 Programming Error Messages 11 1 Error Messages EXXXX Error Message Error Code Description E0000 System error Error code XXX A system error occurred Please info
221. r 34 ELCOT LCOT Busy out Loop Relay Default OFF Value Range 1 ON 2 OFF Description Function When a CO line is busied out manually by the Manager an Operator the status of Loop Relay is controlled by this setting Reference e 1 3 System Features F G Trunk Busy Out e 4 4 12 Trunk Busy Out Setting U M Parameter 35 GCOT Busy out Loop Relay Default OFF RING OPEN Value Range 1 ON 2 OFF RING GND 3 OFF RING OPEN Description Function When a CO line is busied out manually by the Manager an Operator the status of Loop Relay and Ring FG are controlled by this setting Reference e 1 3 System Features F G Trunk Busy Out e 4 4 12 Trunk Busy Out Setting U M Programming Guide System Parameter 36 Tone Mode Default Type 1 Value Range 1 Type 1 2 Type 2 3 Type 3 4 Type 4 5 Type 5 6 Type 6 7 Type 7 Description Function Specifies the Tone output type Note e The change of this parameter is activated after resetting the system Reference None Parameter 37 Ring Mode Default Type 1 Value Range 1 Type 1 2 Type 2 3 Type 3 4 Type 4 5 Type 5 6 Type 6 Description Function Specifies the Ringing Tone type Note e The change of this parameter is activated after resetting the system Reference None Parameter 38 First Digit Time out Process Default Don t release the trunk Value Range 1 Release the trunk 2 Don t release the trunk Description Function Specifies the treatment o
222. r 53 External BGM On Off Default 35 Value Range 1 4 digits consisting of 0 9 or Description Function Specifies the feature number for turning on off External BGM For Manager Operator only Reference e 4 4 2 Background Music BGM External U M Parameter 54 Live Call Screening Default 799 Value Range 1 4 digits consisting of 0 9 or Description Function Specifies the feature number for setting canceling Live Call Screening feature Reference e 4 3 43 Live Call Screening LCS U M Parameter 55 Call Log Incoming Overwrite Mode Default 56 Value Range 1 4 digits consisting of 0 9 x or Description Function Specifies the feature number for turning on off the Call Log Incoming Overwrite Mode If turned on e g 561 overwriting the buffer will occur If turned off e g 560 new data will be disregarded when the buffer is full Reference e 4 5 4 Call Log Incoming KX T7436 KX T7433 KX T7235 KX T7230 only U M Parameter 56 Call Log Incoming Log Lock Default 57 Value Range 1 4 digits consisting of 0 9 x or Description Function Specifies the feature number for turning on off the Call Log Incoming Log Lock A 3 digit password is needed Use it twice e g 57123123 to turn on the lock and use it once i e 57123 to turn off the lock For Manager Operator only Reference e 4 5 5 Call Log Incoming Log Lock KX T7436 KX T7433 Programming Guide KX T7235 KX T7230 only U M 95
223. r Card No Display only Clock Configuration Priority 1 8 None or 101 314 T1 BRI PRI23 1 3 Trunk Port Assignment Program Default Card No Group No DID card 47 Others 1 Status 1 4 Extension Port Assignment Program Default Card No Attribute TEL Tel Type Display only DN 1001 Programming Guide 359 Default Values Program Default Group No 1 Parallel XDP DHLC card Parallel Parallel XDP HLC card None Status DN Refer 1 5 VPS DPT Port Assignment Program Default TVS No 1 VPS Card None Type None Jack No Display only Port No Blank Ext No 1 DN Blank Ext No 1 Group No Blank Ext No 2 DN Blank Ext No 2 Group No Blank Status DN Refer 1 6 T1 Port Assignment Program Default Card No Channel Type Undefined DN Blank Group No Blank Status DN Refer 360 Programming Guide Default Values 1 7 DISA Port Assignment Program Default Card No 1 8 Location Display only Card No 1 8 OGM Group No 1 1 8 BRI Port Assignment Program Default Card No Type co DN Blank Group No 1 Status DN Refer 1 9 PRI Port Assignment Program Default Card No T
224. ral Incoming Groups as the copy destination by clicking it them directly 5 Point to Execute and click e Are you sure is displayed 6 Point to LYS Y and click e Copying is displayed while the source data is being copied to the destination e Parameters of the destination Incoming Groups are immediately effective when copying is finished Parameter Group No Default 1 Value Range 1 96 Description Function Specifies the Incoming Group 1 96 which you are going to program Reference e 1 3 System Features F G Incoming Group Parameter Copy Default Value Range Description Function You can enter into Incoming Group Copy screen by clicking this button Reference Programming Guide 183 Group 184 Parameter FDN Default Blank Value Range 3 4 digits consisting of 0 9 Description Function Specifies the FDN Floating Directory Number for the Incoming Group Reference e 1 3 System Features F G Floating Station Parameter DN Refer Default Value Range Description Function Displays the list of DNs FDNs which are already assigned to the extensions system resources Reference None Parameter Group Type Default DIL 1 N Value Range 1 DIL 1 N 2 Terminate 3 Ring 4 Operator 5 UCD Description Function Specifies the Group Type for each Incoming Group This determines how the Incoming Group handles the incoming call
225. ram Reference 1 2 Slot Assignment P G Parameter Port No Default 1 Value Range 1 n n 4 DID n 16 BRI n 23 PRI23 n 24 T1 n 8 Others Description Function Specifies the trunk port which you are going to program Reference e 1 3 Trunk Port Assignment P G Parameter Copy Default Value Range Description Function You can enter into Trunk Line Copy screen by clicking this button Reference _ Parameter Group No Default Display only Value Range 1 48 Description Function Displays the Trunk Group to which the trunk line is assigned Note e Each trunk line is assigned to a Trunk Group in Section 1 3 Trunk Port Assignment Reference 1 3 Trunk Port Assignment P G Programming Guide 201 Line 202 Parameter Name Default CO001 CO192 Value Range Up to 10 characters consisting of 0 9 A Z a z or the following marks lt gt 7 amp Description Function Specifies the name for the trunk line Note e This is shown on a display PT when receiving a call using this trunk Reference e 1 17 Display Features F G Display Call Information Parameter Incoming Type Default 1 DIL ELCOT GCOT LCOT T1 GCO T1 LCO card 2 DID DID T1 DID card 3 DID ISDN BRI PRI23 card 4 TIE T1 TIE card Value Range 1 DIL 2 DID 3 DID ISDN 4 MDN 5 TIE Description Function Specifies how the incoming CO call via this trunk line is routed to the
226. rameter Timer Setting Default Value Range Description Function You can enter into ISDN Protocol Timer screen Section 1 2 11 Card Properties BRI PRI23 ISDN Protocol Timer by clicking Timer Setting on this screen Reference None Programming Guide Configuration Parameter Software Information Default Display only Value Range Description Function Displays the ROM version of the BRI card software and ROM checksum Reference None 1 2 9 Card Properties BRI SPID DN Used to assign the SPID and the DN on an ISDN BRI port basis You can get these information from the ISDN provider SPID DN 104 BRI Line No 1 SPID Max 20 Digits DN Max 20 Digits SPID Service Profile Identifiers The ISDN switch needs to have a unique identification number for each ISDN BRI port to which it sends calls and signals DN Directory Number Used to decide the ISDN BRI call destination Assign this number as DID MDN No in Section 9 2 1 DID Dial Registration Note e When an extension user makes an outside call using an ISDN BRI line the number stored in DN lt Section 1 2 9 Card Properties BRI SPID DN gt is displayed on the telephone of the other party as the CLIP number Programming Guide 33 Configuration Parameter SPID Default Blank Value Range Up to 20 digits consisting of 0 9 x or P Pause Description Function Specifies an SPID on an IS
227. re installed in the system Card Properties data of one card can be copied to those of all other same type optional cards at a time This eliminates the needs to edit each Card Properties data one by one Up to 16 optional cards can be specified as the copy destination The following example shows how to copy the Card Properties data of a DHLC card assigned to Slot No 1 to other DHLC cards assigned to Slot No 2 to 5 Copying the Card Properties to Other Card Properties 1 Edit the Card Properties of the copy source card a DHLC card assigned to Slot No 101 and save it e Please refer to Editing Card Properties Parameters on Page 7 2 Point to the Card button of Slot No 101 and click e Slot No 101 screen is displayed Slot No 101 8 Programming Guide Configuration Properties Copy 3 Point to e Card Properties Copy screen is displayed and click Gard Properties Copy 4 Point to Select All and click e All displayed Slot Nos will be highlighted e You can specify a certain Slot No individually by clicking it directly Programming Guide 9 Configuration Card Properties Copy DHLC Card Copy Copy from 101 Max 16 Cards Execute Cancel Help i 5 Point to Execute and click e Are you sure is displayed 6 Point to Yes Y and click e Executing is displayed while the source data is being copied to th
228. retrieving a call held at another extension Reference 4 3 11 Call Hold U M Parameter 33 Hold Retrieve Trunk Default 53 Value Range 1 4 digits consisting of 0 9 X or Description Function Specifies the feature number for retrieving a specific outside call held at another extension Reference 4 3 11 Call Hold U M Programming Guide System Parameter 34 Redial Default Value Range 1 4 digits consisting of 0 9 or Description Function Specifies the feature number for dialing the last number dialed Reference 4 3 66 Redial U M Parameter 35 Call Park Call Park Retrieve Default 52 Value Range 1 4 digits consisting of 0 9 or Description Function Specifies the feature number for placing a call on hold retrieving the call held in the system common parking area Reference 4 3 12 Call Park U M e 4 3 22 Conference 5 Party U M Parameter 36 Account Code Default 49 Value Range 1 4 digits consisting of 0 9 x or Description Function Specifies the feature number for entering account codes which may be forced or optional depending on Class of Service programming Reference e 4 3 2 Account Code Entry U M Parameter 37 Door Open Default 55 Value Range 1 4 digits consisting of 0 9 or Description Function Specifies the feature number for unlocking the Door Opener Reference e 4 3 29 Doorphone Call U M Parameter 38 External Feature Access Default
229. rm your distributor how the error was generated and what the error code was E0001 Cannot create temporary file There is insufficient free space on your hard disk or this software is not installed correctly E0002 Illegal password The password entered while making the connection didn t correspond to the one that had already been registered E0003 System error ID XX An error code was returned by the Windows System Library of the Microsoft Windows operating system The error code was XX Please inform your distributor how the error was generated and what the error code was E0004 The file XX doesn t exist Tried to open the data file XX that doesn t exist E0005 Illegal programming version Tried to open the data file that was made in the newer software version of PC programming than one being used at present E0006 Communication error A communication error occurred between your PC and the PBX Or the port parameters of your PC do not match the port parameters of the PBX E0007 Communication error of the modem XX XX stands for the result code that was received from the modem E0008 Cannot open COM port The COM port of your PC is being used by some other application Or the device cannot be used for some reason E0009 COM port access failed ID XX XX stands for the error code of the Microsoft Windows operating system E0010 Communication time out Cannot detect a respons
230. rn 09 Pattern 10 Pattern 11 Pattern 12 ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF Programming Guide o a 20 ety ff t128 135 System 136 Parameter 21 Illegal Number DISA Default Send reorder tone Value Range 1 Send reorder tone 2 Transferred to IRNA destination Description Function Specifies the treatment of the invalid DISA calls Reference e 1 5 Attended Features F G Direct Inward System Access DISA Parameter 22 Illegal Number DID Default Send reorder tone Value Range 1 Send reorder tone 2 Transferred to IRNA destination Description Function Specifies the treatment of the invalid DID calls Reference e 1 5 Attended Features F G Direct Inward Dialing DID e 2 3 ISDN Attended Features F G Direct Inward Dialing DID Parameter 23 Illegal Number TIE Default Send reorder tone Value Range 1 Send reorder tone 2 Transferred to IRNA destination Description Function Specifies the treatment of the invalid TIE calls Reference 3 1 TIE Line Features F G TIE Line Service Parameter 24 Sending dial tone to TIE trunk Default Disable Value Range 1 Enable 2 Disable Description Function Specifies whether or not the system sends a dial tone to a TIE caller after recognizing an incoming TIE call Reference 3 1 TIE Line Features F G TIE Line Service Programming Guide System
231. rosoft and Windows are either registered trademarks or trademarks of Microsoft Corporation in the United States and or other countries e Screen shots reprinted with permission from Microsoft Corporation e All other trademarks identified herein are the property of their respective owners 2 Programming Guide Table of Contents Table of Contents 1 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 2 2 1 2 2 2 3 2 4 2 5 2 6 2 7 2 8 2 9 3 3 1 3 2 3 3 3 4 3 5 3 6 4 4 1 4 2 4 3 4 4 4 5 4 6 4 7 5 5 1 5 2 5 3 5 4 5 5 5 6 Cont uration ences ease eds ioss ideoita casiers tousen Gea ia ies odei isit COMPUTATION 2 nc5 Foxe c tis sccceclovcect Er EREE IAEA AATA AE EEEE EEA 6 SIOCASSISMMENE ronson ain ae aA EEA ANEA AN 7 Tronk Port ASSIgn me tits cscscctsccsciesccccedcaes cocaces sesedecceesdaccbsteossbeteaescevdvesdsdsnechses ascsestiacsens 52 Extension Port ASsignment cccsccsssssscsssssccssssssccssssssssssccescssssssssssssssssssssssesessssens 54 MPS DPT Port ASSISTAMICHt5 35 stsecsececesveacsenssseceesesacesesssbenssoneceosesencnsseanssobesnesasseasss 59 TEL Port ASSiGMMeNt ici ce sseciecsicceccsi Atvcsscseunasecevetssecbencssetsvccaeatvcsbenevncacadoacssecveedesabesveacdense 65 DISA Port ASSIONIMNENE i555 sissscesccessecses scsncssssessusneseonsvessassseues cee ssocsesosessseesssesssoxesoseevenesese 68 BRI Port Assignment s scivsccceevscoscedssescecessscecesescaceseseacesedcocavensscacvessc
232. roup 6 a phantom extension or 7 an ISDN extension except the wild card character X E3002 Invalid directory number for overflow destination Only DN of an extension or FDN of an extension group an incoming group a phantom extension or an external pager TAFAS can be assigned as an overflow destination However the type of DN FDN assignable depends on Group Type E3003 Invalid directory number for UCD supervisor extension Only DN of an extension can be assigned as UCD supervisor extension Programming Guide 343 Programming Error Messages Error Message Error Code Description E3004 Extension group number duplicated Each extension group in the same paging group must have a unique number E3005 The extension group already belongs to another paging group An extension group cannot belong to two or more paging groups E3006 Invalid directory number for Incoming group destination Only DN of an extension or FDN of an extension group can be assigned as an incoming group destination E3008 Invalid directory number for DISA built in Automated Attendant Tables Both DN of extensions and FDN of extension groups or incoming groups or phantom extensions or TAFAS can be assigned as DISA built in Automated Attendant Tables E3009 Incoming group destination duplicated The directory number of the extension or extension group must be unique as a destination E3010 Invalid Mailbox
233. rror Messages Error Message Error Code Description E1006 You have exceeded the system limit of AGC cards There is a limit of 8 AGC cards per system E1007 You have exceeded the system limit of remote cards One RMT card or one ERMT card can be installed in the system only one E1008 You have exceeded the system limit of DPH cards There is a limit of two DPH cards per system E1009 The slot next to a T1 card must be empty Please remove and re assign the card that is installed next to a T1 card A T1 card must go into slot no 1 5 or 9 E1010 You must change card type to None before changing to new card type This process is required to make sure that all data for previous card is deleted E1011 The card of clock configuration priority duplicated Each card must have a unique priority E1012 The status of the card is not INS In Service To use this port you must put the card INS In Service When the card is INS In Service status all the ports of the card become in service E1013 Cannot change the attribute of the port which is the paired extension of a DSS console The attribute of this port cannot be changed until it is de assigned as the paired extension of a DSS console Please change the attribute after de assignment E1014 You have exceeded the system limit of DSS consoles There is a limit of 64 consoles per system E1015 Incomplete directory number The DN and FDN
234. runk Route Control For Manager Operator only Reference e 4 4 13 Trunk Route Control U M Parameter 75 UCD Monitor Mode Default 725 Value Range 1 4 digits consisting of 0 9 or Description Function Specifies the feature number for UCD Monitor mode One supervisor can be assigned per UCD Group The supervisor can monitor the number of calls in the waiting queue Reference 4 3 81 UCD Monitor Mode U M Parameter 76 TIE Line Access Default 77 Value Range 1 4 digits consisting of 0 9 or Description Function Specifies the feature number for making a TIE line call Reference 3 1 TIE Line Features F G TIE Line Service Programming Guide System Parameter 77 92 Other PBX 01 Other PBX 16 Default Blank Value Range 1 2 digits consisting of 0 9 Description Function Specifies the leading 1 or 2 digits of the other PBX extension numbers If you employ PBX code method for TIE calls this programming is not required Reference 3 1 TIE Line Features F G TIE Line Service 9 2 DID Dial Registration P G Parameter 93 Paging Deny Set Cancel Default 721 Value Range 1 4 digits consisting of 0 9 or Description Function Specifies the feature number for setting canceling Paging Deny feature Reference e 4 3 57 Paging Deny U M Parameter 94 Trunk Busy out Default 726 Value Range 1 4 digits consisting of 0 9 or Description Function Specifies the feature
235. s Description Function Specifies the maximum time that the system waits after sending the DISC disconnection message to ISDN before receiving the reply to it Reference None Parameter Extension T306 Default 30s Value Range 0 255 s Description Function Specifies the maximum time that the system waits after sending the DISC disconnection message to ISDN before receiving the reply to it This setting is used when inband tone is supplied Reference None Parameter Extension T310 Default 10 s BRD 40 s PRI23 Value Range 10 300 s Description Function Specifies the maximum time that the system waits after receiving the CALL PROCEEDING call setting acceptance message before receiving the continuance message Reference None Parameter Extension T3D3 Default 30s Value Range 1 120 s Description Function Specifies the time that the system tries to establish L2 in Permanent mode Reference None Programming Guide 43 Configuration Parameter Extension T3D9 Default 0 s BRI 20 s PRI23 Value Range 0 255 s Description Function Specifies the time that the system tries to disconnect L2 in Call by Call mode Reference None 1 2 12 Card Properties DISA Used to set the parameters for the DISA card Card Properties 108 DISA Standard DECISION Count d ei SEES Parameter CYCLIC Tone Detection Mode Default Standard Value Range 1 Standard 2 Option Description Fu
236. s Night Lunch Break 0 ring 2 6 Local Hunt Sequence Program Default Trunk Group No 01 1 Others None 2 7 Trunk to Trunk Restriction Program Default Source Trunk Group No 1 Destination Trunk Group No 1 48 No check 2 8 System Option 2 8 1 System Option 1 Program Default 1 Sound source during transfer Music on Hold SLT On hook with consulting held call Consulting Hold Release the trunk 2 3 FLASH button operation while CO talking 4 FLASH button operation when Don t release the trunk is selected at 3 Disconnect and hear CO dial tone 5 Limited call duration Both calls 6 Transfer recall destination Originating extension 7 Checking dial by toll restriction Check Programming Guide 367 Default Values Program Default 8 Confirmation tone for Override Barge in Enable Conference and Privacy Release 9 Confirmation tone for Call Pickup Paging Enable Paging Answer TAFAS Answer Hold Retrieve and Call Park Retrieve 10 Station Speed Dialing Initial display Name 2 8 2 System Option 2 Program Default 11 Sending pulse signal during CO call Enable 12 Automatic adjustment of the clock using No Caller ID information 13 DISA prolong operation No limit 14 Dialing in DISA CO to CO talking Disconnect and make a new call
237. s directed to it 1 DIL 1 N Functions as a DIL 1 N Group 2 Terminate Functions as a Station Hunting Group Terminate 3 Ring Functions as a Ring Group 4 Operator Functions as an Operator Group 5 UCD Functions as a UCD Uniform Call Distribution Group Reference e 1 3 System Features F G Incoming Group Programming Guide Group Parameter Overflow Setting Destination Day Night Default Blank Value Range 3 4 digits consisting of 0 9 Description Function Specifies the destination extension where the call is transferred to when all extensions in the Incoming Group are unavailable or logged out in Day Night mode respectively Assignable only when Terminate Operator or UCD is specified in Group Type programming Reference None Parameter Overflow Setting Timer Default None Value Range None 5 180 s in 5 s increments Description Function Specifies the length of time in seconds the system is to wait before transferring the call in the waiting queue to the Overflow Destination Assignable only when Operator is specified in Group Type programming Note e If None is specified the call is transferred to the Overflow Destination immediately Reference e 1 3 System Features F G Operator Group Parameter Mailbox No Default Blank Value Range 3 4 digits consisting of 0 9 Description Function Specifies the mailbox number for the Incoming Group When an i
238. scription Function Specifies the length of ringing time in seconds of the Timed Reminder alarm Reference e 1 8 Ringing Features F G Timed Reminder Wake Up Call Timed Reminder Remote Wake Up Call e 4 3 74 Timed Reminder Wake Up Call U M e 4 4 11 Timed Reminder Remote Wake Up Call U M 118 Programming Guide System Parameter Call Parking Recall Time Default 60 s Value Range 0 1800 s Description Function Specifies the length of time in seconds the system is to wait before alerting Call Parking Recall the extension who parked the call Note e If 0 is specified Call Parking Recall does not occur Reference e 1 10 Holding Features F G Call Park e 4 3 12 Call Park U M Parameter TIE Inter digit Time Default 5s Value Range 3 30 s Description Function Specifies the maximum time allowed between digits on a TIE call after it was received by the system Reference 3 1 TIE Line Features F G TIE Line Service Parameter DISA Prolong Time Default 3 min Value Range 0 7 min Description Function A CO to CO line call duration is initially limited by CO to CO Line Call Duration Time However prolonging the CO to CO line call duration is possible To prolong the call duration the caller should press any dialpad key except x The amount of prolonging is set by DISA Prolong Time 0 7 minutes If this is set to zero then prolonging is disabled Depending on 13 DISA
239. scription Function Specifies the maximum data transmission speed between the ERMT card and the modem which is connected to a Personal Computer Maintenance Device Reference 3 4 3 Remote Administration Remote Connection I M CPU Card Information Used to confirm the Software Version and the Area Code GPU Gard Information Software Version Q951AA0306068 Area Code 1 Programming Guide 47 Configuration 1 2 15 48 Parameter Software Version Default Display only Value Range Description Function Displays the System ROM version Reference None Parameter Area Code Default Display only Value Range 0 31 Description Function Indicates the jumper setting on the CPU card thereby revealing what area country the system is intended for Reference None TSW Card Configuration Used to set the parameters for the TSW card TSW Card Configuration Programming Guide Configuration Parameter Option Card Status Conference Expansion Card Default Display only Value Range 1 Not Installed 2 Installed Description Function Displays whether an optional Conference Expansion Card is installed or not Reference e 1 12 Conversation Features F G Conference 3 Party Conference 5 Party Conference Unattended Parameter Option Card Status Digital OHCA Card Default Display only Value Range 1 Not Installed 2 Installed Description F
240. sert T1 card into a free slot Notes e Tl card should be installed in the free slot no 1 5 or 9 of each shelf e The next slot must be empty 2 Assign the card type of the slot to T1 in 1 1 Slot Assignment screen 3 Assign the channel type and the trunk group number of each port in 1 5 T1 Port Assignment screen Assign the directory number and the extension group number when the channel type is assigned to OPX Note e The channel type should be assigned on the basis of the contract with a telephone exchange 4 When the channel type of the port is assigned to a trunk line LCO GCO DID or TIE E amp M assign the parameters of the port like usual trunk line in 4 1 Trunk Line screen When the channel type is assigned to OPX assign the parameters of the port like usual extension line in 4 2 Extension Line screen 5 Change the card status to INS In Service in 1 1 Slot Assignment screen All the ports are changed to INS In Service status automatically Programming Guide 65 Configuration Parameter Card No Default Value Range XXX T1 XXX Card No 101 314 Description Function Specifies the physical number of the T1 digital trunk card which you are going to program Reference 1 2 Slot Assignment P G Parameter Channel Type Default Undefined Value Range 1 Undefined 2 LCO 3 GCO 4 DID 5 TIE E amp M 6 OPX Description Function Specifies the type of T1 i
241. sources Reference None Programming Guide 67 Configuration 1 7 DISA Port Assignment Used to assign OGM group number for each DISA card location OGM Group hoy Bocana Hocanor OO i Crete ple GGM Groupo Bocanom locana OE Creiiies ple Ej Cipeitics ler location Horatiom OGi Group hoy 6 OGM Group Gy Parameter Card No 1 8 Location Default Display only Value Range 101 314 Description Function Displays the slot number of the DISA card which you are going to program Reference 1 2 Slot Assignment P G Parameter Card No 1 8 OGM Group No Default 1 Value Range 1 8 Description Function Specifies the OGM Group 1 8 to which the DISA card is assigned Reference e 1 3 System Features F G Outgoing Message OGM 3 6 OGM Group P G 68 Programming Guide Configuration 1 8 BRI Port Assignment Used to assign the parameters for BRI Basic Rate Interface ports 1 8 BRI Port Assignment 101 BRI Parameter Card No Default Value Range XXX BRI XXX Card No 101 314 Description Function Specifies the physical number of the BRI card which you are going to program Reference 1 2 Slot Assignment P G Programming Guide 69 Configuration 70 Parameter Type Default CO Value Range 1 CO 2 EXT Description Function Specifies the type of each BRI port either CO CO line or EX
242. ssssscecssees 2D 7 7 1 ARS Automatic Route Selection cccssssssssssscsscssssssssecessscccscscccccccccccscccccececees 288 7 2 Time Table siscesecisessestdensessscssoveecsecssenssceetccstesvessscseesvostessosecessssssuteasacedessecedensecsveeseseces 289 Ta Leading Digits Table cronni aaa a NA Aa NATI AaS SONERAA 290 TA Routine PLAN 50550085052 cebdecdt dec caces EEN E NA EEEE ERS 292 7 5 Digits Modification Table oessecssccsscssccssccsccessocsocesoossosssocesosssecssosesecssesescesocesossos 294 8 Private Network sssssssosooseosssesooooosososoosossososoosesossossosessossosesessse 29 7 SEL Private Network a ssissescsesdscscossesicessessvesacscssvsesssetecsesssesnctesseessestoesseaeessesonssencdssesesneseees 298 8 2 TIE Routing Table sesccsccseecsscssecsconsssaccseneccssnsstesesvondsssutessssssndecsousesdssevseuesdenecsesedeeseasveds 299 9 DID Dial ieeinoeccesicsssorssssssstseorscssessosssscsseesoe oest oot enseoe soosse L 91 DID Dial eeens sin ni E AA AKA E N AN NE ES 302 9 2 DID Dial Registration oesesooesscocsssoossssooessooesssoosesoossssosssssoosssoossssoosssooesesossssoosesso 303 10 Maintenance osssoeooooososesoosessssossosoosossosesoossososesosesssssssosessssssse JOI LOD MaintenantE vase cc ccscsscccsecsesccseossevscsdsesesennscssesdevnse sosiece soscecwesedesedsosecedcosesvsesssensecsoseesse 310 10 2 External Modem 1 2 sccceccscceccsssessssscosesvsseaccesseoesevsnsvessstcsnestecsoosesseaesecsoses
243. stem sends the DID number to the VPS when DPT Integration is activated If set to Enable the Toll Saver and DID Call Routing features of the VPS can be used Please refer to the VPS manual for further information Reference e 1 3 System Features F G Integration DPT 147 Programming Guide System 2 9 PRI Originating Control Used to specify the inter digit timers and the trunk group on an outgoing call using an ISDN PRI line 2 9 PRI Originating Control 2 9 PRI Originating Contro Parameter PRI Inter digit Timer 1 Default 5s Value Range 1 30 s Description Function Specifies the maximum time allowed between each digit on an outgoing call using an ISDN PRI line Note e This timer applies to the call after the number of digits determined by Dial counter for PRI Inter digit Timer 2 is dialed Reference None 148 Programming Guide System Parameter PRI Inter digit Timer 2 Default 3s Value Range 1 30 s Description Function Specifies the maximum time allowed between each digit on an outgoing call using an ISDN PRI line Note e This timer applies to the call before the number of digits determined by Dial counter for PRI Inter digit Timer 2 is dialed Reference None Parameter Dial counter for PRI Inter digit Timer 2 Default 7 digits Value Range 0 24 digits Description Function Specifies the number of digits to activa
244. sy Reorder 48 Call Pickup with DSS S CO key Disable 49 LCD Display Mode while CO talking Caller ID 2 8 5 System Option 5 Program Default 56 Redial with ISDN Do not send dials entered during conversation 57 VPS Auto Configuration Mode Create mailboxes only for the tenant which has VPS ports 58 Release of BRI PRI line while talking when DISCONNECT signal is received Don t Release 59 ARS Call Timeout Mode Local Access 60 Empty Group Allow Programming Guide 369 Default Values 2 8 6 System Option 6 Program Default 61 Auto Answer with held call Disable 63 VM Trunk Service for DID Disable 64 CNIP Service Disable 65 Alert Ringing Disable 67 Sending DID Number to VPS Disable 2 9 PRI Originating Control Program Default PRI Inter digit Timer 1 5s PRI Inter digit Timer 2 3s Dial counter for PRI Inter digit Timer 2 7 digits PRI TRG Assignment All No check 3 Group 3 1 Group 3 2 Trunk Group 3 2 1 Trunk Group 1 2 Program Default Group No 1 Copy Intercept Destination Day Night Blank Pause Time before Flash Signal 512 ms Max Dial No after EFA Signal 0 Line Hunting Order Reverse Tenant No 1 Flash Time 600 ms Disconnecting Time 1 55 Pause Time 1 5 s 370 Programming Guide Default Values
245. t DID card 47 Others 1 Value Range 1 48 Description Function Specifies the trunk group 1 48 to which the trunk port is assigned Note e Each trunk port must be assigned to a Trunk Group This program defines the Trunk Group assignment for each trunk port Reference e 1 3 System Features F G Trunk Group 3 2 Trunk Group P G Programming Guide Configuration Parameter Status Default Value Range 1 INS 2 OUS 3 FAULT Description Function Specifies the operating status of the trunk port 1 INS The trunk port is In Service 2 OUS The trunk port is Out of Service 3 FAULT The trunk port is defective Reference None Programming Guide 53 Configuration 1 4 Extension Port Assignment Used to set various parameters for extension ports XDP extensions are on ports 9 through 16 of a DHLC card 1 3 Extension Port Assignment moe 1 3 Extension PortAssignment ellllllel Parameter Card No Default Value Range XXX YYY XXX Card No 101 314 YYY Card Type Description Function Specifies the physical number of the extension card and its type which you are going to program Reference e 1 2 Slot Assignment P G 54 Programming Guide Configuration Parameter Attribute Default TEL Value Range 1 TEL 2 DSS 3 VPS DPT Description Function Specifies the attribute of the terminal which is t
246. t not exceed 16 characters Truncate it Truncate means that the leading 16 characters are saved and the rest are deleted W5009 VPS integration code must not exceed 3 digits Truncate it Truncate means that the leading 3 digits are saved and the rest are deleted W5010 Voice Mail command must not exceed 16 digits Truncate it Truncate means that the leading 16 digits are saved and the rest are deleted W5011 Local Area Code must not exceed 6 digits Truncate it Truncate means that the leading 6 digits are saved and the rest are deleted W5012 Additional dial must not exceed 4 digits Truncate it Truncate means that the leading 4 digits are saved and the rest are deleted 350 Programming Guide Programming Error Messages Message Code Description W5013 Caller ID name must not exceed 16 characters Truncate it Truncate means that the leading 16 characters are saved and the rest are deleted Wws5014 Caller ID number must not exceed 24 digits Truncate it Truncate means that the leading 24 digits are saved and the rest are deleted W5022 Existing entries will be lost Do you wish to continue Import operation erases all Caller ID names and numbers stored in 5 12 Caller ID Registration screen Ww7001 ARS Leading dial must not exceed 10 digits Truncate it Truncate means that the leading 10 digits are saved and the rest are deleted W7002 ARS additional dial must not exceed 20 dig
247. t the line at the instant the assigned number of digits are dialed Note e This program can be added if the CPC Signal Detection is not provided by the Central Office e 1 3 System Features F G Calling Party Control CPC Signal Detection Programming Guide System Parameter Automatic Hold Default Disable Value Range 1 Enable 2 Disable Description Function Used to turn on off Automatic Hold feature Reference e 1 10 Holding Features F G Automatic Hold For Hold Automatic Hold For Transfer Parameter SDN COS Default Own Extension Value Range 1 Own Extension 2 PDN Description Function This setting is applied when an extension user makes an outside call using an SDN button on his own extension Assignable for a DN type PT extension only 1 Own Extension COS TRS level of his own extension is applied to the call when making an outside call using the SDN button 2 PDN COS TRS level of the owner extension is applied to the call when making an outside call using the SDN button Reference e 1 16 Button Features F G Programming Guide Button Line Access e 2 2 3 Flexible Button Assignment U M e 3 2 5 005 Flexible CO Button Assignment U M 109 System 2 4 2 Trunk Group Setting 110 Used to specify the trunk group that the extension user can use for making an outside call The following screen is shown on the display by clicking of Service screen
248. te PRI Inter digit Timer 2 The number of digits specified by the dial counter is N While N digits are dialed PRI Inter digit Timer 1 applies After N digits are dialed PRI Inter digit Timer 2 applies Reference None Parameter PRI TRG Assignment Default All No check Value Range 1 Check Effective 2 No check Not Effective Description Function Specifies the trunk group 01 48 which the extension user can use for making an outside call using an ISDN PRI line If checked the special PRI timers work for originating using the PRI line Reference None Programming Guide 149 System 150 Programming Guide Group Section 3 Group Programming Guide 151 Group 3 1 Group Used to assign various group parameters E TD500 Mainten 152 Programming Guide Group 3 2 Trunk Group 3 2 1 Trunk Group 1 2 Used to assign parameters for each trunk group Up to 48 trunk groups can be created in the system Note To support efficient utilization of trunks it is desirable to group them together in trunk groups according to a type of each trunk Incoming Only Outgoing Only or Both Way determined by the contract with the Central Office 3 1 Trunk Group 1 2 fia ow fw E af Sinatsioms fo oo _ 17 boone F a me M E M Programming Guide 153 Group Trunk Group Copy Used to copy a part of or all settings of a certain
249. the Type of Number applied to the outgoing CO calls via ISDN Public Switched Telephone Network Reference None Programming Guide 161 Group 162 Parameter Type of Number Outgoing Private Default Default Value Range 1 Default 2 Unknown 3 International 4 National 5 Network Specific 6 Subscriber Description Function Specifies the Type of Number applied to the outgoing CO calls via ISDN Private Network Reference None Parameter Type of Number Incoming Public Default Default Value Range 1 Default 2 Unknown 3 International 4 National 5 Network Specific 6 Subscriber Description Function Specifies the Type of Number applied to the incoming CO calls via ISDN Public Switched Telephone Network Reference None Parameter Type of Number Incoming Private Default Default Value Range 1 Default 2 Unknown 3 International 4 National 5 Network Specific 6 Subscriber Description Function Specifies the Type of Number applied to the incoming CO calls via ISDN Private Network Reference None Programming Guide Group Parameter Cyclic Signal Detection Default Check Value Range 1 No check Disable 2 Check Enable Description Function Used to disconnect the trunk line when the system detects a cyclic signal during a CO to CO line call by DISA or AGC Reference e 1 5 Attended Features F G Direct Inward System Access DISA Parameter Continuous Signal Detecti
250. the intercom call on Consultation Hold or not Reference 1 9 Answering Features F G Hands free Answerback e 4 3 40 Hands free Answerback U M Parameter 63 VM Trunk Service for DID Default Disable Value Range 1 Disable 2 Enable Description Function Specifies whether to enable or disable the tenant assigned on a DID No basis If Disable is selected then the tenant no works for the CO lines belonging to the Trunk Group Reference 9 2 DID Dial Registration P G Programming Guide System Parameter 64 CNIP Service Default Disable Value Range 1 Disable 2 Enable Description Function Specifies whether or not to use the CNIP ISDN service on outgoing CO calls Reference e 2 2 ISDN Originating Features F G Calling Name Identification Presentation CNIP Parameter 65 Alert Ringing Default Disable Value Range 1 Disable 2 Enable Description Function Specifies whether or not to alert the alert extension when the extension user does not respond to the Timed Reminder wake up call Reference e 1 8 Ringing Features F G Timed Reminder Wake Up Call Timed Reminder Remote Wake Up Call e 4 4 11 Timed Reminder Remote Wake Up Call U M e 4 3 74 Timed Reminder Wake Up Call U M 2 2 Tenant P G Alert Extension Day Night Parameter 67 Sending DID Number to VPS Default Disable Value Range 1 Disable 2 Enable Description Function Specifies whether or not the sy
251. timing before sending DTMF signal 1 5 s Follow on ID Pause timing before sending DTMF signal RBT 1 5 s BT Turn off control of Message Waiting lamp System Start AA service after FWD IRNA of CO call Do not start Extension s mailbox number Programmed number Call from AA port to AA port Allow 380 Programming Guide Default Values Program Default Sending out Follow on ID after FWD Enable Sending out Follow on ID after IRNA Disable 5 11 Caller ID Modification Program Default Local Call Area Code Blank Local Call Digits to delete No 1 3 Others 0 Local Call Number to be added Blank Long Distance Call Digits to delete 0 Long Distance Call Number to be added 1 5 12 Caller ID Registration 5 12 1 Caller ID Registration Program Default Tenant No 1 Entry No 0001 0010 Import from Sys Speed Dial Name Blank Number Blank 5 13 UCD Time Table Program Default Table No 1 Command Sequence 1 16 None Programming Guide 381 Default Values 6 Toll Restriction 6 1 Toll Restriction 6 2 TRS Deny Code Program Default TRS Level 6 Entry No 001 020 Dial Blank 6 3 TRS Exception Code Program Default TRS Level 6 Entry No 001 020 Dial Blank 7 ARS Automatic Route Selection 7 1 ARS Automatic Route Selection 7 2 Time Tabl
252. tion Code Confirmation Tone Default 9 Value Range Up to 3 digits consisting of 0 9 or Description Function Specifies the Confirmation Tone code Sent to the Voice Mail port when the Message Waiting Lamp On or Message Waiting Lamp Off code is dialed successfully Reference 1 3 System Features F G Integration VPS Parameter Integration Code FWD to VM Ringback Tone Default 6 Value Range Up to 3 digits consisting of 0 9 or Description Function Specifies the FWD to VM Ringback Tone code Sent to the Voice Mail port when the extension dialed is forwarded to Voice Mail and another VM Voice Mail port is able to answer the call This lets the first Voice Mail port usually an Automated Attendant send the call to the other Voice Mail ports Reference e 1 3 System Features F G Integration VPS Programming Guide Features Parameter Integration Code FWD to VM Busy Tone Default 7 Value Range Up to 3 digits consisting of 0 9 or Description Function Specifies the FWD to VM Busy Tone code Sent to the Voice Mail port when the extension dialed is forwarded to Voice Mail and no other Voice Mail ports are available to accept the call This signals the Voice Mail port usually an Automated Attendant to let the caller leave a message Reference e 1 3 System Features F G Integration VPS Parameter Integration Code FWD to Extension Ringback Tone Default 8 Value Range Up to 3
253. tion tone for Override Barge in Conference and Privacy Release Default Enable Value Range 1 Enable 2 Disable Description Function Allows you to remove Confirmation Tone 4 This tone is sent when a three party conference is established finished Reference e 1 13 Audible Tone Features F G Confirmation Tones Parameter 9 Confirmation tone for Call Pickup Paging Paging Answer TAFAS Answer Hold Retrieve and Call Park Retrieve Default Enable Value Range 1 Enable 2 Disable Description Function Allows you to remove Confirmation Tone 3 This tone is sent when a conversation is established just after an extension user dials the feature number for accessing the following features Call Pickup Paging Paging Answer TAFAS Answer Hold Retrieve and Call Park Retrieve Reference e 1 13 Audible Tone Features F G Confirmation Tones Programming Guide System Parameter 10 Station Speed Dialing Initial display Default Name Value Range 1 Name 2 Number Description Function Specifies the initial display of a display DPT such as KX T7235 KX T7436 in Station Speed Dialing Reference e 4 5 8 KX T7235 Display Features Call Directory U M 2 8 2 System Option 2 e 4 5 10 KX T7431 KX T7433 KX T7436 Display Features U M Used to assign system option parameters No 11 No 20 2 7 System Option 2 Parameter 11 Sending pulse signal during CO call Default Enable Valu
254. to assign ARS parameters E TD500 Maintenance Console Programming 288 Programming Guide ARS Automatic Route Selection 7 2 Time Table Used to make up ARS time schedules It is possible to split a day into four time zones maximum so that the least expensive line is selected for that time Enter the starting time of each zone according to the service hours and charges offered by your carriers 7 1 ARS Time Table EELEELELL ahhh EECELEL aeaee EELEELLEL saelehe EEE o ew cance eee Parameter Time A B C D SUN MON TUE WED THU FRI SAT Default Time A 8 00AM Time B 5 00PM Time C 9 00PM Time D Disable Value Range Hour 01 12 AM PM Disable Description Function Specifies starting time Hour 01 12 AM PM Disable of the applied Route List Reference e 1 6 Originating Features F G Automatic Route Selection ARS 7 4 Routing Plan P G Programming Guide 289 ARS Automatic Route Selection 7 3 Leading Digits Table Used to determine the appropriate Route Plan Table number for a call by analyzing the extension user dialed number Up to 800 Leading Digits entries can be programmed in the system 7 2 ARS Leadine Digits Table 7 2 Leading Digits Table v EEEE Parameter Entry No Default 001 020 Value
255. ton is pressed by the extension user Reference e 1 3 System Features F G Host PBX Access e 4 3 35 External Feature Access U M Parameter PBX Access Code Default Blank Value Range 1 4 digits consisting of 0 9 X or Description Function Specifies the PBX access codes required to access the Host PBX or Centrex service If the system is installed behind a host PBX or a Centrex system an access code is required to make an outside Centrex call or to access Centrex features Up to four codes can be assigned per Trunk Group Reference e 1 3 System Features F G Host PBX Access e 4 3 35 External Feature Access U M Parameter Numbering Plan ID Outgoing Public Default Default Value Range 1 Default 2 Unknown 3 ISDN Telephony 4 National Standard 5 Private Description Function Specifies the Numbering Plan ID applied to the outgoing CO calls via ISDN Public Switched Telephone Network Reference None Programming Guide 159 Group Parameter Numbering Plan ID Outgoing Private Default Private Value Range 1 Default 2 Unknown 3 ISDN Telephony 4 National Standard 5 Private Description Function Specifies the Numbering Plan ID applied to the outgoing CO calls via ISDN Private Network Reference None Parameter Numbering Plan ID Incoming Public Default Default Value Range 1 Default 2 Unknown 3 ISDN Telephony 4 National Standard 5 Private Description Function Specifies the Num
256. ts e The port number is displayed only when the attribute of the port is assigned to VPS DPT Reference 1 4 Extension Port Assignment P G Programming Guide 61 Configuration 62 Parameter Ext No 1 DN Default Blank Value Range 3 4 digits consisting of 0 9 Description Function Specifies the extension for B1 channel Notes e This program allows you to assign an extension number to each Voice Mail port Since each port connected to the VPS provides two extensions this enables you to assign extension numbers to each port To reach the Voice Mail system users dial these extension numbers e When you swap DN you already programmed among Jacks you must clear these DNs once Reference 2 3 Numbering Plan P G Parameter Ext No 1 Group No Default Blank Value Range 1 128 Description Function Specifies the Extension Group 1 128 to which the B1 channel of the VPS DPT port is assigned Note e Specifies the extension group 1 128 to which the type of extension group VM or AA is assigned Reference e 1 3 System Features F G Extension Group 3 3 Extension Group P G Programming Guide Configuration Parameter Ext No 2 DN Default Blank Value Range 3 4 digits consisting of 0 9 Description Function Specifies the extension for B2 channel Notes e This program allows you to assign an extension number to each Voice Mail port Since each port connected to the VPS pro
257. tting feature Default Value Range Description Function Reference Enable 1 Enable 2 Disable If enabled the system notifies the extension user by sending a special dial tone Dial Tone 2 when one or more of the following features are assigned on his extension e Absent Message Capability e Background Music BGM e Call Forwarding e Call Pickup Deny e Call Waiting e Data Line Security e Do Not Disturb DND e Electronic Station Lockout e Executive Busy Override Deny e Paging Deny e Pickup Dialing e Timed Reminder Also enabled is Dial Tone 4 indicates that messages are waiting Note e Dial Tone 3 is not affected by this setting e 4 Tones Ring Tones F G e 6 1 3 Tone List U M Parameter 17 Destination Busy DISA Default Value Range Description Function Reference Programming Guide Send busy tone 1 Send busy tone 2 Transferred to IRNA destination Specifies the treatment of DISA callers when they dial a busy extension e 1 5 Attended Features F G Direct Inward System Access DISA 131 System 132 Parameter 18 Destination Busy DID Default Send busy tone Value Range 1 Send busy tone 2 Transferred to IRNA destination 3 Wait till the destination becomes idle Description Function Specifies the treatment of DID callers when they dial a busy extension Reference e 1 5 Attended Features F G Direct Inward Dialing DID
258. ture that disconnects an outside call when a specified timer expires A warning tone is sent to the extension user 15 seconds 10 seconds and 5 seconds before the time limit Both calls means incoming and outgoing calls Note e This setting applies to the extension on which Time Limit of Outside Calls is enabled by COS programming Reference e 1 3 System Features F G Limited Call Duration Parameter 6 Transfer recall destination Default Originating extension Value Range 1 Originating extension 2 Operator Description Function Specifies whether Transfer Recall occurs at the transfer originating extension or at Operator Group extensions if the call both inside and outside transferred to an extension is not answered within a specified period of time Reference e 1 11 Transferring Features F G Programming Guide Call Transfer 127 System 128 Parameter 7 Checking dial by toll restriction Default Check Value Range 1 No check Disable 2 Check Enable Description Function Specifies whether or not the system checks the user dialed x and during Toll Restriction procedure Note e This assignment is required for certain Central Offices COs to prevent toll fraud Some Central Offices ignore the user dialed and If your CO is such a type select No check Reference e 1 6 Originating Features F G Toll Restriction for Special Carrier Access Parameter 8 Confirma
259. u can enter into Flexible CO Key screen Section 4 3 2 by clicking CO Key on this screen Reference e 2 2 3 Flexible Button Assignment U M e 3 2 5 005 Flexible CO Button Assignment U M Parameter PF Key Default Value Range Description Function You can enter into Flexible PF Key screen Section 4 3 3 by clicking PF Key on this screen Reference e 2 2 3 Flexible Button Assignment U M Programming Guide 215 Line 216 Parameter Initial Display Selection Default Caller ID Value Range 1 Caller ID 2 Trunk Name 3 DID Name Description Function Specifies the initial display of a display PT when an incoming CO call with Caller ID information comes in on it Reference e 2 2 6 Initial Display Selection U M Parameter COS No Primary Default 1 Value Range 1 96 Description Function Specifies the Primary COS Class of Service to the extension Reference e 1 3 System Features F G Class of Service COS e 4 4 10 Switching COS U M Parameter COS No Secondary Default 1 Value Range 1 96 Description Function Specifies the Secondary COS Class of Service to the extension Reference e 1 3 System Features F G Class of Service COS e 4 4 10 Switching COS U M Parameter Preferred Line Outgoing Default Prime Line ICM PDN Value Range 1 No Line 2 Idle Line 3 Prime Line ICM PDN 4 Prime Line CO Description Function Specifies the line to which the extension is connected
260. unction Displays whether an optional Digital OHCA Card is installed or not Reference e 1 3 System Features F G Integration DPT e 1 6 Originating Features F G Off Hook Call Announcement OHCA Off Hook Call Announcement OHCA Whisper Parameter System Clock Status Default Display only Value Range 1 Internal 2 External Description Function Displays current System Clock Status Reference e 1 3 System Features F G Programming Guide T1 Carrier e 2 1 ISDN Features F G Integrated Services Digital Network ISDN 49 Configuration Parameter Clock Configuration Mode Default Value Range Description Function Reference External 1 Internal 2 External Specifies the system clock mode to Internal or External 1 Internal The system synchronizes to a clock pulse provided by the internal clock on the TSW card N External The system synchronizes to a clock pulse provided by the Digital Network Note e External should be selected when the system is connected to the Digital Network e 1 3 System Features F G T1 Carrier e 2 1 ISDN Features F G Integrated Services Digital Network ISDN Parameter Clock Configuration Master Card No Default Value Range Description Function Reference 50 Display only 101 314 T1 BRI PRI23 Displays the physical number of the T1 BRI PRI23 card which currently provides External Clock
261. unk line before sending the dialing digits to the Central Office other PBX by default This allows the Central Office other PBX enough time to accept the dialing digits correctly Specifies the appropriate value depending on the requirements of your local Central Office Reference e 1 3 System Features F G T1 Carrier e 1 5 Attended Features F G Direct Inward Dialing DID e 3 1 TIE Line Features F G 4 2 Trunk Line P G Start Signal Type Parameter Break Default 60 Value Range 1 60 2 67 Description Function Specifies the break for pulse digits This is the ratio between on hook and off hook signals during digit transmission Reference e 1 3 System Features F G T1 Carrier Parameter Pulse Feedback Tone Default Yes Value Range 1 Yes 2 No Description Function On outgoing CO calls the dialed number is toned out which informs the extension users that dialed number has been dialed out The dialed number is toned out by default Select No to turn off the pulse feedback tone Reference e 1 3 System Features F G T1 Carrier Programming Guide Configuration Parameter Signaling Bit Monitor Port No Default Disable Value Range 1 Disable 2 Port No 1 24 Description Function Specifies the port to monitor the signaling bit using the LED on the T1 card Note e This setting is valid when the LPR software version of the T1 card is Y311D or later Reference e 4 7 D
262. vices Digital Network ISDN Extension e 3 1 TIE Line Features F G TIE Line Service 4 7 ISDN Extension Line P G Parameter DN Default Value Range Description Function Reference Programming Guide Blank 3 4 digits consisting of 0 9 or X Specifies the DN Directory Number for the PRI port Assignable only when EXT is specified in Type assignment Notes e X can be used as a wild card character which substitutes any digit in its position The last one or two digits of DN may be Ux e This setting is valid when the LPR software version of the PRI23 card is Q361AB or later 2 3 Numbering Plan P G 13 Configuration 74 Parameter Group No Default 1 Value Range 1 48 or 1 128 Description Function Type CO QOsig Master Osig Slave Specifies the Trunk Group 1 48 to which the PRI port is assigned Type EXT Specifies the Extension Group 1 128 to which the PRI port is assigned Reference e 1 3 System Features F G Extension Group Trunk Group e 3 1 TIE Line Features F G TIE Line Service 3 2 Trunk Group P G 3 3 Extension Group P G Parameter Status Default Value Range 1 INS 2 OUS 3 FAULT Description Function Specifies the operating status of the PRI port 1 INS The PRI port is In Service 2 OUS The PRI port is Out of Service 3 FAULT The PRI port is defective hardware In this case the LED indicator on the PRI23 car
263. vides two extensions this enables you to assign extension numbers to each port To reach the Voice Mail system users dial these extension numbers e When you swap DN you already programmed among Jacks you must clear these DNs once Reference 2 3 Numbering Plan P G Parameter Ext No 2 Group No Default Blank Value Range 1 128 Description Function Specifies the Extension Group 1 128 to which the B2 channel of the VPS DPT port is assigned Note e Specifies the extension group 1 128 to which the type of extension group VM or AA is assigned Reference e 1 3 System Features F G Extension Group 3 3 Extension Group P G Parameter Status Default Value Range 1 INS 2 OUS 3 FAULT Description Function Specifies the operating status of the VPS DPT port 1 INS The VPS port is In Service 2 OUS The VPS port is Out of Service 3 FAULT The VPS port is defective Reference None Programming Guide 63 Configuration Parameter DN Refer Default Value Range Description Function Displays the list of DNs FDNs which are already assigned to the extensions system resources Reference None 64 Programming Guide Configuration 1 6 T1 Port Assignment Used to assign parameters for T1 ports 1 5 T1 Port Assignment 101 11 onaetnes E Undeines Z Undefined Z E E BEEBE ETN J 1 5 T1 Port Assignment v How to set up a T1 card 1 In
264. wered Reference e 1 3 System Features F G Programming Guide Station Message Detail Recording SMDR 317 Maintenance 318 Parameter Print out Timed Reminder Information Default Disable Value Range 1 Enable 2 Disable Description Function If this is enabled SMDR will print out Timed Reminder Start each time the timed reminder alarm starts ringing In addition if it is answered SMDR will print out Timed Reminder Answer and if it is not answered SMDR will print out Timed Reminder No Answer Reference e 1 3 System Features F G Station Message Detail Recording SMDR e 1 8 Ringing Features F G Timed Reminder Wake Up Call Timed Reminder Remote Wake Up Call Parameter Print out Account Code Default Enable Last Entered Code Value Range 1 Enable First Entered Code Last Entered Code 2 Disable Description Function Specifies whether or not the Account Code will be printed out by SMDR If this is enabled SMDR will print out the first entered account code or the last entered account code when two or more different account codes are entered during a single call Reference e 1 3 System Features F G Account Code Entry Parameter Print out LOGIN LOGOUT Default Disable Value Range 1 Enable 2 Disable Description Function Specifies whether or not the Login Logout status of Extension Group Incoming Group members and Phantom extensions will be printed out by SMD
265. xtension 3 or 4 digits for Intercept Routing feature in both Day and Night modes respectively Notes e Intercept Routing provides an automatic re direction of calls that have not been answered e There are seven possible destinations of intercepted call 1 An extension 2 an external pager TAFAS 3 an OGM group 4 an extension group 5 an incoming group 6 a phantom extension or 7 an ISDN extension except the wild card character X e 1 11 Transferring Features F G Intercept Routing 229 Line Parameter Call Forwarding No Answer Time Default 0 ring Value Range 0 12 rings Description Function Specifies the number of rings before the Call Forwarding No Answer feature is activated If a call is not answered before the programmed number of rings the call is redirected to the pre assigned extension Note e If O is specified Call Forwarding No Answer Time setting in Section 2 5 System Timer works Reference e 1 11 Transferring Features F G Call Forwarding e 4 3 9 Call Forwarding U M 2 5 System Timer P G 230 Programming Guide Line 4 4 DSS Console Used to assign the paired extension for a DSS Direct Station Selection Console and the usage of DSS and PF buttons seyi PE Key Cony AUB 4 3 DSS Console Programming Guide 231 Line DSS Console Copy Used to copy a part of or all settings of a certain DSS Console to all other DS
266. y T3D9 Default 20s Value Range 0 255 s Description Function Specifies the time that the system tries to disconnect L2 in Call by Call mode Reference None Parameter Extension T200 Default ls Value Range 1 5 s Description Function Specifies the maximum time that the system waits after sending the L2 command to ISDN before receiving the reply to it Reference None Programming Guide 41 Configuration 42 Parameter Extension T203 Default 10s Value Range 1 60 s Description Function Specifies the time to detect no communication status of L2 Reference None Parameter Extension T302 Default 10 s BRD 15 s PRI23 Value Range 2 30 s Description Function Specifies the maximum time allowed between each digit on an incoming call Applies to the overlap receiving Reference None Parameter Extension T303 Default 5 s BRI 2 s PRI23 Value Range 2 12 s Description Function Specifies the maximum time that the system waits after sending the SETUP call setting message to ISDN before receiving the reply to it Reference None Parameter Extension T304 Default Os Value Range 0 255 s Description Function Specifies the maximum time allowed between each digit on an outgoing call Applies to the overlap receiving Reference None Programming Guide Configuration Parameter Extension T305 Default 30 s BRD 4 s PRI23 Value Range 4 30
267. ype CO DN Blank Group No 1 Status 2 System 2 1 System 2 2 Tenant Program Default Tenant No 1 Operator FDN Blank Alert Extension Day Night Blank DAY NIGHT Switching Mode Manual Programming Guide 361 Default Values Program Default Inter tenant Calling 1 8 No check Auto Start Time Day SUN SAT 9 00 AM Night SUN SAT 5 00 PM Lunch Start SUN SAT 12 00 PM Lunch End SUN SAT 1 00 PM Break Start SUN SAT 3 00 PM Break End SUN SAT 3 30 PM Music on Hold Source MUS1 BGM Source MUS1 Manager Extension DN Blank System Speed Dialing Entries Max Tenant No 1 1000 Tenant No 2 1000 Tenant Nos 3 8 0 Automatic Route Selection No check External Paging Tone Check System Speed Dial TRS Level Override No check Confirmation Tone for Station or External Paging Check 2 3 Numbering Plan Program Default 1 1st Hundred Block Extension 10 2 2nd Hundred Block Extension 11 3 3rd Hundred Block Extension 12 4 4th Hundred Block Extension 13 5 5th Hundred Block Extension 14 6 6th Hundred Block Extension 20 7 7th Hundred Block Extension 21 8 8th Hundred Block Extension 22 9 9th Hundred Block Extension 23 10 10th Hundred Block Extension 24 11 16 11th Hundred Block Extension 16th Blank Hundred Block Extension 362 Programming Guide Default Values
Download Pdf Manuals