Home
HWg-Ares 12 MANUAL: GSM/GPRS thermometer
Contents
1. Load a previously stored configuration from a setup xml file e Save Settings Save the current configuration into a setup xml file e Device reset Restart the device e Set to factory Default Restore factory default settings of the device e Save Save all changes February 2012 www HW group com page 27 HVVg Ares HVV group How to reduce operating costs HVVg Ares units offer functions for reducing overhead GSM GPRS costs particularly in the following scenarios e Networks that limit the maximum volume of transferred data e Subscribers without a flat rate data plan Primary cost saving options e Disabling GPRS Internet functions e Disabling data services when roaming outside of the home network e Terminating GPRS connection when idle for longer than 60 seconds Special functions Alarm information after power up When any sensor or digital input is in alarm when the power is connected all alarm messages according to Ares configuration are sent as soon as the GSM GPRS connection is established Text message commands 1234 STATUS Test Value OFF 0 of input Input 1 is on state normal Your HWgAres12 1234 is default password You have to use it if your number is not listed in 5 SMS recipients e STATUS or STATUS SMS Sends a text message with the current status e STATUS EMAIL Sends an e mail with the current status e RESET or REBOOT Restarts the Ares unit e DEBUG Returns debugging inf
2. Connected data logging suspended while USB connected This tab gives information about sensors and digital inputs together with graphical symbols for quick overview e Device name Device name Useful for sorting in higher level systems or to tell apart several Ares units e Temperature Unit Units used to work with temperature The temperature unit changes about 5 seconds after pressing Save Celsius C Kelvin K Fahrenheit F e Current Time Informs about the current system time set in the device The time appears in the log of measured values e Last Sync Time Date and time of last time synchronization over the Internet Useful for checking if the time synchronization works e Modem status Information about the current modem status and readiness SIM unplugged No SIM was found Insert a SIM or clean its contact pads Modem initializing Modem is being initialized The device is establishing communication with the modem and making the modem ready for operation This information should not appear for more than 10 s Otherwise it indicates a modem fault see Troubleshooting Invalid PIN PIN code stored in the Ares unit is incorrect PUK requested PUK code is needed must be entered in a different kind of device Ready to use Modem is registered to the carrier s network and ready for operation Dialing Connection to the carrier is being dialed necessary
3. e Save Save all changes February 2012 www HW group com page 19 HVVg Ares HVV group SMS Template tab all AresConf configuration utility f General Digital Inputs Sensors SMS Templ Email Email Templ GSM GPRS intemet Portal Logger System SMS Templates Template User 1 Text M5G TYPE Hi t5RC_NAMFS value 5RC VALUESSSRC UNITS is on state 5RC_ STATUS Your DEV NAME Help list of supported macros Status Done USB Conection Connected data logging suspended while USB connected Use this tab to define the formats of individual messages e g to distinguish temperature alarm messages from humidity alarm messages or to define the contents of status and reminder messages e Template Selects the template to edit e Text Message contents with macros as variables e Help list of supported macros List of macros that can be used in the message e Preview Display a dialog with a preview of the message e Save Save all changes Macros window General DEV NAME MSG TYPE Source sensor ESRC VALUE SRC UNIT ESRC STATUS ESRC MINS ISRC MAX 5RC_RLARM Sensor with TD xxXxE February 2012 www HW group com page 20 HVVg Ares HVV group Preview window Alarm ACTIVATED Hi Input 1 value Open 0 is on state normal Your Ares February 2012 www HW group com page 21 HVVg Ares HVV group E mail tab ed AresConf configuration utility for HWg Ares wwwHW
4. groupcom le Email Templ GSM GPRS Intemet Alarm Email Settings Outgoing Server Settings Recipient 1 olmr hw cz SMTP Server mail hw cz Recipient 2 SMTP Port 25 Recipient 3 Lsemame smtp Recipient 4 Password _ E Show Password Recipient 5 Importance Secure Connection SSL N STARTTLS Report End of Alarm General Email Settings Alarm Reminder Period D disable 0 minutes Outgoing Email Address ares 12 hwg cz Send Test Email Clean Email Queue Status Done USB Conection Connected data logging suspended while USB connected Use this tab to configure alarm e mail recipients and parameters e Recipient 1 5 Addresses of recipients for alarm e mails e Importance Importance of the e mail message Useful for mail filtering in e mail clients e Report End of Alarm Users will be also informed when an alarm ends global setting e Alarm reminder Send reminders about active alarms o Period Period of alarm reminders in minutes o Template Template to use for the reminder message e SMTP Server IP address or host name of the SMTP server to use for sending e mail e SMTP Port TCP port where the SMTP server listens e Username Username for authentication to the SMTP server e Password Password for authentication to the SMTP server e Show Password Display the actual password instead of asterisks e Secure Connection SSL No STARTTLS Enables encrypted authentic
5. later must be discovered manually Detected sensors are automatically added to the list e Delete All Delete all discovered sensors Sensor no 65535 is a system entry and cannot be deleted e Save Save all changes e Hyst Hysteresis for the given sensor e Templ Alarm message template See the SWS Templ and Email Templ tabs The template is configured independently for each sensor February 2012 www HW group com page 17 HVVg Ares HVV group Time tab SNTP Setup Time Setup SNTP Server europe pool ntp org New Day 8 11 2011 Time Zone New Time 18 42 09 Sync Period Set Time Manually Daylight Saving Time Sync after Device Startup Synchronize Time Status Done USB Connection Connected data logging suspended while USB connected Use this tab to configure the current system time The time can be set either manually in Time Setup or automatically over the Internet e SNTP Server URL or IP address of the time server to use o List of stratum one time servers https support ntp org bin view Servers StratumOneTimeServers o List of stratum two time servers https support ntp org bin view Servers StratumTwoTimeServers List of NIST time servers http tf nist gov tf cgi servers cgi List of NTP pool servers https support ntp org bin view Servers NTPPoolServers and http www pool ntp org e Time Zone Time zone where Ares is used e Sync Period Indicates how often to synchronize time ov
6. or host name of the SMTP server to use for sending e mail e SMTP Port TCP port where the SMTP server listens e Username Username for authentication to the SMTP server e Password Password for authentication to the SMTP server e Show Password Display the actual password instead of asterisks e Secure Connection SSL No STARTTLS Enables encrypted authentication e Outgoing Email Address Sender e mail address E mails will be sent to the recipients from this address e Subject Subject prefix Useful for adding a keyword to the e mail subject in order to simplify mail filtering e Send Test Email Send a test e mail to all listed recipients e Save Save all changes Ask your network administrator or mobile carrier for this information February 2012 www HW group com page 13 HVVg Ares HVV group Advanced settings Advanced settings are enabled by pressing the Show in Advanced Mode button General tab al AresConf configuration utility for HWg Ares www HW group com Show in Advanced Mode USB Connection Digital Inputs Current Value 0 0 1 Device Name Temperature Unit Curent Time 8 11 2011 13 49 36 Last Sync Time 8 11 2011 8 07 58 Modem Status Connected to Intemet Name Current Value Sensor 1369 11 375 C Battery Monitor 100 Signal Quality 53 dBm 96 Reg operator Vodafone CZ FW Version 1 0 5h Email Queue 0 5M5 Queue o Status Done USB Conection
7. 0 271 192 111 Report Certificate Number 12 23 Report Certificate Date 16 8 2012 Signed on behalf of HW group s r o Dated 29 8 2012 Jan Rehak Managing Director Acting as Responsible Person Manufacturer Prague Czech Republic Europe yy HYV group com
8. A E E EEE ETA EN E 32 February 2012 www HW group com page 3 HVVg Ares HVV group Basic features e Quadband modem GSM 850 900 1800 1900 MHz e Number of 1 Wire sensors o Aresi12 2 o Ares 14 12 e External antenna e Support for PIN protected SIM e Alarm alerts o SMS up to 5 phone numbers o Ringing a specified number up to 5 phone numbers o Email up to 5 addresses with selectable priority e User templates for SMS and Email alarms different for each sensor e Periodic reminders about active alarms e Per sensor hysteresis settings e Logs periodically e mailed to up to 5 addresses independent from Alarm addresses with selectable priority e Configurable global interval for storing measured values 15 minutes by default e Support for portal based solutions with the HWg PUSH protocol o Periodic data transfer o Data transfer when values differ by more than the specified tolerance e Status request o SMS from a predefined number o SMS from any number containing a password o Ringing the device from a predefined number e Internal memory for measured values 2 MB 170 000 records e Simple configuration vvith an intuitive VVindovvs utility e Connects to PC over USB without special drivers Mass Storage HID e Power failure indication through a virtual input Supports alarms e Battery status indication supports alarms e Option to activate deactivate GPRS when roaming SMS alarms and control still 100 functional e Wall mount DIN ra
9. GPRS Internet tab Connected sensor cannot be found Make sure that the sensors are properly connected e Restart Ares e Press Find Sensors on the Sensors tab to detect the missing sensor e Press Delete All Sensors to remove all sensors then press Find Sensors to find them again I am receiving too many alarm messages Check the hysteresis setting By default hysteresis is set to 1 without regard to the measured quantity However in some cases this hysteresis is too low February 2012 www HW group com page 29 HVVg Ares Internal memory size HVVg Ares is equipped vvith 2MB internal memory for storing measured values The available recording time depends on the number of values being stored One value takes up 12 bytes of memory Therefore 2048kB 1024 2 097 152B 12B approximately 170 000 records due to the internal memory organization the actual number is slightly smaller Examples 3 values Stored once per 300 s 170 000 3 56 666 records 4722 hours 196 days 1 value Stored once per 30 s 170 000 records 85 000 minutes 1416 hours 54 days 2 values Stored once per 180 s 170 000 2 85 000 records 4250 hours 177 days 1 Wire UNI sensors 1 Wire sensors are connected using RJ 12 jacks 1 Wire UNI sensors are a special kind of 1 Wire sensors They communicate using the same protocol over the same interface but also contain added circuitry for connecting special probes For this reason 1 Wire UNI sensor
10. HLVoroup HVVg Ares 12 14 MANUAL HVVg Ares HVV group Package contents A complete shipment contains the follovving items e HVVg Ares unit e Printed manual datasheet Safety information The device complies with regulations and industrial standards in force in the Czech Republic and the European Union The device has been tested and is supplied in working order To keep the device in this condition it is necessary to adhere to the following safety and maintenance instructions Using the device in a manner other than prescribed by the manufacturer may cause its safeguards to fail The power supply outlet or disconnection point must be freely accessible In particular the device must not be used under any of the following conditions e The device is noticeably damaged e The device does not function properly e Unfastened parts can move inside the device e The device has been exposed to moisture or rain e The device has been serviced by unauthorized personnel e The power adapter or power supply cable are noticeably damaged e If the device is used in a manner other than designed for the protection provided by the device may fail e The local electrical system must include a power switch or a circuit breaker and overcurrent protection If you have any problems with installing or operating the device please contact technical support HW group s r o http www hw group com Email support OHVVg cz U Pily 3 143 00 Pra
11. asic properties of sensors e State Graphical information about sensor states same as on the General tab e 1D Unique sensor ID e Name Sensor name used for easier overview and for further processing in other systems e Current Value Current sensor value e Min Lower limit of the Safe Range If the value is less than MIN Alarm is automatically set e Max Upper limit of the Safe Range If the value is more than MAX Alarm is automatically set e Email Send an e mail when the input is in Alarm e SMS Send a text message SMS when the input is in Alarm e Del Remove the sensor from the list e g when the sensor is disconnected If the sensor remains physically connected it will be detected again when the Ares unit is restarted Sensor no 65535 is a system entry and cannot be deleted e Find Sensors Detect all connected sensors By default sensors are detected only when the unit is powered up Sensors connected later must be discovered manually Detected sensors are automatically added to the list e Delete All Delete all discovered sensors Sensor no 65535 is a system entry and cannot be deleted e Save Save all changes February 2012 www HW group com page 11 HVVg Ares HVV group SMS tab Show in Advanced Mode Alam SM5 Settings Recipient 1 Recipient 2 Recipient 3 Recipient 4 Recipient 5 Report End of Alarm Send Test SMS Status Done USB Connection Connected d
12. ata logging suspended while USB connected Use this tab to configure alarm text message SMS recipients Each recipient phone number is also authorized to request information from Ares 12 by dialing the unit s phone number and to send SMS commands without a password see Advanced settings e Recipient 1 5 Phone numbers where to send alarm text messages SMS o Ring out Upon alarm dial the given number The phone rings for 15 seconds or until the call is refused e Report End of Alarm Users will be also informed when an alarm ends global setting e Send Test SMS Send a test SMS to all configured numbers e Save Save all changes February 2012 www HW group com page 12 HVVg Ares HVV group E mail tab Show in Advanced Mode Alarm Email Settings Outgoing Server Settings Recipient 1 SMTP Server mail hw cz Recipient 2 SMTP Port 25 Recipient 3 Usemame smtp Recipient 4 Password _ E Show Password Recipient 5 Secure Connection SSL is Mi E STARTTLS Report End of Alarm General Email Settings Outgoing Email Address 9 ares 12 hwg cz Subject Ares Send Test Email Status Done USB Conection Connected data logging suspended while USB connected Use this tab to configure alarm e mail recipients and parameters e Recipient 1 5 Addresses of recipients for alarm e mails e Report End of Alarm Users will be also informed when an alarm ends global setting e SMTP Server IP address
13. ation e Outgoing Email Address Sender e mail address E mails will be sent to the recipients from this address e Subject Subject prefix Useful for adding a keyword to the e mail subject in order to simplify mail filtering e Send Test Email Send a test e mail to all listed recipients e Clean Email Queue Clear all unsent e mails from the queue e Save Save all changes Ask your network administrator or mobile carrier for this information February 2012 www HW group com page 22 HVVg Ares HVV group Email Template tab al AresConf configuration utility for HWg Ares www HW group com Email Templates Template Subject usei gt Subj SDEV NAME SMSG TYPE ORC NAMES value 5RC_VALUES 5SRC UNITS is on state 5RC_STATUSs Your DEV NAME Help list of supported macros Status Done Use this tab to define the format of individual messages e g to distinguish temperature alarm messages from humidity alarm messages or to define the contents of status and reminder messages e Template Selects the template to edit e Subject Subject of the e mail Macros can be used e Text Message contents with macros as variables e Help list of supported macros List of macros that can be used in the message See the SMS Template tab e Preview Displays a dialog with a preview of the message See the SMS Template tab e Save Save all changes February 2012 www HW group com page 23 HVVg Are
14. com page 9 HVVg Ares HVV group Digital Inputs tab al AresConf configuration utility for HWg Ares www HW group com Name 0 Name 1 OFF ON OFF OFF Status Done USB Conection Connected data logging suspended while USB connected Use this tab to configure basic properties of digital inputs e State Graphical information about input states same as on the General tab e ID Unique sensor ID e Name Digital Input name used for easier overview and for further processing in other systems e Current Value Current input state o O Open power disconnected o 1 Closed power applied e Name 0 Name of the state when the input is Off contact open e Name 1 Name of the state when the input is On contact closed e Alarm Alert Specifies when the input is in Alarm o Disable Alarm is disabled for this input o Active if ON 1 Alarm when the input is On closed o Active if ON 0 Alarm when the input is Off open e Email Send an e mail when the input is in Alarm e SMS Send a text message SMS when the input is in Alarm e Save Save all changes February 2012 www HW group com page 10 HVVg Ares HVV group Sensors tab Mame Current Value Min Max Email SMS Del Sensor 1369 11 299 C 6 oo g 65535 Battery Monitor 100 2 Pool O O Status Refreshig values USB Connection Connected data logging suspended while USB connected Use this tab to configure b
15. em entry that informs about the battery charge level February 2012 www HW group com page 15 HVVg Ares HVV group Digital Inputs tab al AresConf configuration utility for HVYg res www HW group com Current Value Name 0 Name 1 Alarm Alert Email Templ SMS Templ o om am E E OFF ON Disable M Status Done USB Conection Connected data logging suspended while USB connected Use this tab to configure basic and advanced properties of digital inputs e State Graphical information about input states same as on the General tab e 1D Unique sensor ID e Name Sensor name used for easier overview and for further processing in other systems e Current Value Current input state o O Open power disconnected o 1 Closed power applied e Name 0 Name of the state when the input is Off contact open e Name 1 Name of the state when the input is On contact closed e Alarm Alert Specifies when the input is in Alarm o Disable Alarm is disabled for this input o Active if ON 1 Alarm when the input is On closed o Active if ON 0 Alarm when the input is Off open e Email Send an e mail when the input is in Alarm e SMS Send a text message SMS when the input is in Alarm e Save Save all changes e Templ Alarm message template See the SWS Templ and Email Templ tabs The template is set independently for each input February 2012 www HW group com page 16 HVV
16. er the Internet 1h 24h e Daylight Saving Time Activates automatic change to from DST e Sync After Device Startup Synchronize time over the Internet whenever the device is powered on e New Day Shows the current date and lets the user change it manually e New Time Shows the current system time and lets the user change it manually e Synchronize Time Immediately synchronize time Only works when the GPRS connection is functional e Set Time Manually Store the changed date and time values to memory e Save Save all changes February 2012 www HW group com page 18 HVVg Ares HVV group SMS tab al AresConf configuration utility for HWg Ares ov HW groupcomn O SMS Templ Email Templ GSM GPRS Intemet Alam SM5 Settings Status SMS Settings Recipient 1 IMI Ring out Status SMS you can get by sending 5M5 request with ted STATUS to number of your HVWVg Ares if your phone number is not one of five SMS Recipient 2 IF Ring out recipients you have to send SM5 with format PASSWORD STATUS Recipient 3 DI Ring out Status SMS Password E Show Password Recipient 4 E Ring out Recipient 5 King oi Recipient 5 CI Ring out Template Default 7 Send Status SMS if ring from one of the alarm recipients Report End of Alarm Alam Reminder Period O disable 0 minutes Send Test SMS Clean 5M5 Queue Status Done USB Conection Connected data logging suspended while USB connected Use this tab to config
17. g Ares HVV group Sensors tab al AresConf configuration utility for HWg Ares www HW group com Sensor List ID Name Current Value Min ax Email Temp SMS Templ Serial Code Del 65535 Battery Monitor 100 25 0 c C 4012207003072078 26053 Sensor 26053 23 099 C 10 DJ Defaut vj 1 Defaut vj 280565170300003 Find Sensors Delete All Sensors Status Done USB Connection Connected data logging suspended while USB connected Use this tab to configure basic and advanced properties of sensors e State Graphical information about sensor states same as on the General tab e 1D Unique sensor ID e Name Sensor name used for easier overview and for further processing in other systems e Current Value Current sensor value e Min Lower limit of the Safe Range If the value is less than MIN Alarm is automatically set e Max Upper limit of the Safe Range If the value is more than MAX Alarm is automatically set e Email Send an e mail when the sensor is in Alarm e SMS Send a text message SMS when the sensor is in Alarm e Del Remove the sensor from the list e g when the sensor is disconnected If the sensor remains physically connected it will be detected again when the Ares unit is restarted Sensor no 65535 is a system entry and cannot be deleted e Find Sensors Detect all connected sensors By default sensors are detected only when the unit is powered up Sensors connected
18. ha 4 Tel 420 222 511 918 When contacting technical support please note the exact type of your device at the type plate and if possible the firmware version February 2012 www HW group com page 2 HVVg Ares HVV group Table of Contents PACKApe CON cs hc e a ee ee eee 2 Se TMOG C1 OU E E E 2 PASOI a sy syaxte sen ncoonys lt cauecsarecooayssan E yore vunsysusaeonmena E E trons 4 Description of connectors and CONNECTIONS cccceesecccceseccccenseccceesececcueceeeeesececseeceseugeceeseeaeeesseneees 5 SS SS RP PE KT 8 Del MOE AD E E 10 SEE SLS e 1e AE EEEE E EEIE E OEN E PA E EEE 11 TIT 12 FEIN CAO sapere epee teen ve enact pe E 13 en cen TITOS a eC ee eee eee eee 14 GON 14 DISA ORCS Gel aise echo erea cece E E aes 16 Sos a E E E E A E E N 17 TM 18 TI Top 19 Sido 20 EETA Dee a E e PE A IKEN EN I NENI N KITE 22 ERA TEMP leta tern en E One ne a ern E OE eae ee eee ee 23 GSM GRPS Internet taD gas sec 24 POR 25 LOP EN gain os pecs eco cere IA A E EA N EE use treatin NE E E T 26 BO SOI AEE EEE EE EEA EE EE EE EEE AA E EET EE ESE E TE EE EE 27 MOW 0 reduce operating COSTS ga AE EEE 28 Primary cast savine OPON e EEA 28 i 1 2161 Fe 1 BLE La 0 d 9 sroin E S 28 Text message CON AIG e ne a e Ra ee 28 onlne oere S 29 emna ON O a E E E 30 MVS UNISON OT e 30 Customizing user MESSARBES ccseccseccseeceeceecosccesscescceueceuecesecesecesecesecesecesecesectseetseetseetseetaeesseeneenes 31 Ee T E EE E EAEE E E EEA
19. her sensors to include in the message XXXX sensor name XXXX sensor reading XXXX sensor unit of measurement Sensors Invalid Normal Alarm Out Of Range Digital inputs Normal Alarm Lower limit of the Safe Range XXXX Upper limit of the Safe Range XXXX Alarm begin end www HW group com page 31 HVVg Ares HVV group Mechanical _ 76 0 E _ 32 8 e a e i C mias 92 2S BRE rn ja N S a ae T gt o z so E s N o T lt i Y February 2012 vvvvvv HVV group com page 32 HW group EMC Declaration of Conformity Product description HWg Ares 12 14 Manufactured By HW group s r o Address of Manufacturer Rumunska 26 Prague 2 Czech Republic Telephone number 420 222 511918 This is to certify that the above described product conforms will the protection requirements of council directive 89 336 EEC EEC and the amending directives relating to Electromagnetic Compatibility and council directive 73 23 EEC and amending directives relating to the Safety standard EN 61 950 1 by application of Application of EMC Standards EN 61000 6 2 Information technology Equipment Radio disturbance Characteristics EN 61000 6 4 Information Technology Equipment Immunity Characteristics Competent Body Test house report Name Zapadoceska univerzita v Plzni Fakulta elektrotechnicka Elektrotechnicka laborator Address Univerzitni 8 306 14 Plzen Telephone 42
20. il mount options e Firmware upgrade over USB or GPRS On the Fly Over the Air o Upgrade can be started with a SMS command e Logging stops when Ares is connected to USB e Sensors are automatically detected when the device is turned on e Alarm information available immediately after powering up February 2012 www HW group com page 4 HVVg Ares HVV group Description of connectors and connections H W group HWg Ares12 GSM GPRS monitoring SIM Card Sensors LED indicators e Alarm red Indicates alarm status One or more sensors read outside of the allowed range or an alarm at one or more inputs 2x Digital Inputs or external power supply indication e Modem blue Informs about GPRS connection o Fast blinking GPRS connection is being established o On Connection established o Slow occassional blinking Communication takes place e Status yellow o Fast blinking GSM connection is being established o Blinking 1x second Device works normally e Power green Power is connected Blinks when the device runs on battery February 2012 www HW group com page 5 HVVg Ares HVV group Inputs 2x Digital Input for connecting a voltage free dry contact Logic LOW contact open when the resistance between terminals is greater than 15 kOhm Logic HIGH closed contact when the resistance is less than 2 7 kOhm Resistances between these values are undefined Power Power supply 9 30V 500mA can be c
21. ne time transmission of recorded data e Clear log Delete recorded data e Save Save all changes February 2012 www HW group com page 26 HVVg Ares HVV group Build Time Nov 32011 15 22 16 Uptime O days 1 hours 18 min Periodical Restart at Universal Time UTC 2 00 00 Upgrade Upgrade server http new hwg cz download fw version hwg ares 12 js Check for fw version GSM Upgrade Local Upgrade Save Settings Set to Factory Default Status Done USB Connection Connected data logging suspended while USB connected Use this tab to display and set system variables upgrade firmware and save or restore configuration e System o Build Time Date and time of the current firmware build o Uptime Time since last restart e Periodical Restart Automatically restart the device o Daily Once per day o Weekly every Sunday Once every Sunday o Monthly every 1st day of month On the first day of every month o at Universal Time UTC Time for the automatic restart in UTC e Upgrade o Upgrade server Firmware URL or upgrade configuration file URL o Check for fw version If the URL of the config file is specified check for the availability of a firmware upgrade o GSM Upgrade Upgrade the firmware over GSM GPRS Correct address needs to be specified in the Upgrade server field o Local Upgrade Upload firmware from the local computer through a standard dialog window e Load Settings
22. onnected to the power terminals or the power barrel connector The terminals and the connector are interconnected and can NOT be used to connect two different power sources e g adapter and back up battery Sensors 2x independent port for connecting 1 Wire sensors with support for 1 Wire UNI Each port can be connected to a bus maximum length is 60 m The total number of supported sensors is a device wide limitation the sensors can be connected to one port or distributed among both ports in any Way Caution There is a limit of two 1 Wire UNI sensors per port Some 1 Wire UNI sensors may require an active hub see 1 Wire UNI sensors Sim Card Standard plug in SIM GSM SMA connector for an external antenna The external antenna needs to be QuadBand capable and equipped with a male SMA connector External antenna is required for proper operation of the device February 2012 www HW group com page 6 HVVg Ares HVV group Specifications GSM GPRS Quad Band 850 900 1800 1900 MHz GPRS class 10 8 Compliant to GSM phase 2 2 Class 4 2 VV 850 900 MHz Class 1 1 W 1800 1900MHz IP TCP UDP HTTP SNTP SMTP HWg PUSH Ver 1 00 compatible partial ver 2 0 implementation Interface Supported protocols SNMP compatibility SENSORS HVVg original accessories 1 VVire amp 1 Wire UNI RJ11 1 VVire Bus Ares12 Up to 2 sensors Ares14 Up to 14 sensors Up to 60m Type Connector Sens
23. ormation e UPGRADE Without further parameters upgrades the firmware using the configured address Full URL can be included in the message February 2012 www HW group com page 28 HVVg Ares HVV group Troubleshooting Modem does not respond Check the information in the Modem Status field on the General tab e SIM unplugged No SIM was found Insert a SIM or clean its contact pads e Modem initializing Modem is being initialized This information should not appear for more than 10 s Otherwise it indicates a modem fault If this message persists check the SIM clean its contact pads if necessary and press Reset to restart the unit e Invalid PIN PIN code is not entered in the Ares unit or it is incorrect Input the correct PIN in Advanced Config Mode on the GSM GPRS Internet tab e PUK requsted PUK code is required must be entered in a different kind of device The SIM is blocked until the correct PUK is entered Take the SIM out and unblock it in a mobile phone e Dialing Connection to the carrier is being dialed necessary to establish GPRS connection This information should not appear for more than 20 s Otherwise it indicates a modem fault Check the Dial number in Advanced Config Mode on the GSM GPRS Internet tab When in doubt contact your mobile carrier e Configuring Internet Internet connection is being configured reading IP parameters Check the APN in Advanced Config Mode on the GSM
24. ors Sensor distance DRY CONTACT INPUTS 11 12 Digital Input supports NO NC Dry contact ves 1 On 0 500 Q Right pin on the terminal block can be connected to 12V Sensitivity GND Up to 50m POWER input Port Type Connector POWER 9 30V DC Main device power input typically 500 mA Jack barrel inner 2 5 mm outer 6 3 mm Terminal Block Physical parameters Operating 10 to 65 C 14 to 150 F Storage 25 to 85 C 13 to 185 F Dimensions Mass 98 x 92 x 30 mm 150g EMC FCC Part 15 Class B CE EN 55022 EN 55024 EN 61000 Temperature range February 2012 www HW group com page 7 HVVg Ares HVV group First steps Connect Ares to PC vvith an USB cable and open the ARES disk that appears Double click the AresConf application to start it The General tab appears and shows the device status all AresConf configuration utility for HWg Ares www HW group com Show in Advanced Mode USB Connection Device Name Ares Curent Time 8 11 2011 13 49 36 Last Sync Time 8 11 2011 8 07 58 Modem Status Connected to Intemet Current Value 11 375 C 100 Signal Quality 53 dBm 96 Reg operator Vodafone CZ FW Version 1 0 5h Email Queue 0 5M5 Queue 0 Status Done USB Conection Connected data logging suspended while USB connected This tab gives information about sensors and digital inputs together with graphical symbols for quick overview Y
25. ou can set the Device Name and the unit of temperature C F K here The temperature unit changes about 5 seconds after pressing Save When starting the device for the first time pay attention to the mobile network connection and signal strength information If the signal is too weak relocate the antenna If the modem is unable to log in to the GSM network check the PIN security code settings of the SIM For details see Advanced settings Digital Inputs ID 8 External Power is a system entry that indicates connected disconnected external power supply It is used to inform about power failures and battery powered operation Sensors ID 65535 Battery monitor is a system entry that informs about the battery charge level February 2012 www HW group com page 8 HVVg Ares HVV group All deviations from normal are indicated graphically oJ AresConf configuration utility for HWg Ares www HW grou Curent Time 8 11 2011 14 16 45 Last Sync Time 8 11 2011 8 07 58 Modem Status Ready to use Signal Quality 53 dBm 96 Reg operator Vodafone CZ FW Version 1 0 5h Email Queue 0 5M5 Queue 0 USB Conection Connected data logging suspended while USB connected 117 87 Sensor connected value within Safe Range no Alarm disconnected Alarm EA Digital Input out of range upper threshold exceeded Alarm E Digital Input out of range lower threshold exceeded Alarm February 2012 www HW group
26. s HVV group GSM GRPS Internet tab a SIM Card Settings SIM Card PIN E Show Password Enable GPRSfIntemet GPRS Operator Settings Show Advanced GPRS Settings APN Address intemet Usemame Dial Number ATO I9 IH Dialup String Roaming IO Use Intemet connectivity if roaming is detected Status Done USB Conection Connected data logging suspended while USB connected Use this tab to configure the GSM and Internet connection details e SIM Card PIN Specifies the security PIN code for the SIM The SIM can remain protected with the PIN e Show Password Display the entered PIN e Enable GPRS Internet Enable Internet based services such as sending e mail portal services and time synchronization e GPRS Operator Settings Settings for accessing the GPRS network of the mobile carrier o APN Address Access Point Name identifier The default is internet Your mobile carrier can advise if another is needed o Dial Number Phone number for accessing the Internet The default is 99 1 Your mobile carrier can advise if another is needed e Roaming Enable Internet connection outside of the home carrier network e g when traveling abroad e Show Advanced GPRS Settings Display advanced settings that are accessible directly using AT commands for experts only e Username User name for the connection Will be provided by the mobile carrier if needed e Password Password for the connec
27. s may require an additional power supply Sens UDI 86 When the 1 Wire UNI sensors do not explicitly require external power a maximum of two 1 Wire UNI sensors can be connected to one Ares port More sensors can only be connected through the 1 Wire HUB Power active hub HW group 1 Wire UNI sensors strongly influence how long the internal Ares battery lasts This needs to be taken into account when planning your system For more information about connecting 1 Wire UNI sensors carefully read the user manual for the respective sensor February 2012 www HW group com page 30 HVVg Ares HVV group Customizing user messages Ares supports up to 4 user defined custom types of e mail and text messages The follovving macro commands can be used to insert system variables sensor names and measured values List of macro commands Name General DEV_NAME MSG_TYPE Source sensor SRC_NAME SRC_VALUE SRC_UNIT SRC_STATUS SRC_MIN SRC_MAX SRC_ALARM Sensor with ID XXXX SNAME_XXXX VALUE_XXXX UNIT_XXXX STATUS XXXX MIN_XXXX SMAX_XXXX ALARM_XXXX February 2012 Description General macros Device name Message type Alarm status periodic Sensor name Current value Unit of the measured value Sensors Invalid Normal Alarm Out Of Range Digital inputs Normal Alarm Lower limit of the Safe Range Upper limit of the Safe Range Alarm begin end Information about ot
28. ta transmission Delta Humid amp Other Difference in humidities and other quantities that triggers immediate data transmission Refresh Update the received settings Manual Push Manual transmission for test purposes Save Save all changes February 2012 www HW group com page 25 HVVg Ares HVV group Logger al AresConf configuration utility for HWg Ares www HW group com SMS Templ Email Templ GSM GPRS Intemet Log Logger Settings Log Email Settings WARNING Data logging suspended while USB connected Recipient 1 recipient domain com Datalog Total Size 0 bytes Recipient 2 Recipient 3 Log Period D disable seconds Recipient 4 Email Period O disable hours TODO ZATIM W sec Recipient 5 DI Ease Log ater Ena potere Send Test Email Get Log TODO NEFU Status Done USB Connection Connected data logging suspended while USB connected Use this tab to configure logging of measured values e Datalog Total Size Current size volume of recorded data in bytes e Log Period Interval for storing measured values e E mail period Interval for e mailing recorded values e Erase log after e mail Delete recorded values after e mailing them e Recipient 1 5 Addresses of recipients for e mails with logged data e Importance Importance of the e mail message Useful for mail filtering in e mail clients e Send Test Email Send a test e mail to all listed recipients e Get Log O
29. tion Will be provided by the mobile carrier if needed e Dialup String AT string Will be provided by the mobile carrier if needed e Save Save all changes February 2012 www HW group com page 24 HVVg Ares HVV group Portal al AresConf configuration utility for HWg Ares www HW group com E Enable Portal Portal Server Settings Push Settings Server Address http some_server portal xml Push Period O disable seconds Part 20 Log Period O disable seconds Usemame Deta Temperature Password Delta Humidity Manual Push Status Done USB Conection Connected data logging suspended while USB connected Use this tab to configure the HWg PUSH protocol Enable Portal Enable transmission of data to a remote portal HWg PDMS etc Server Address HTTP address of the portal where the data should be sent Port TCP port of the remote portal default 80 Username Username for authentication to the portal Password Password for authentication to the portal Push Settings Current PUSH settings Information is provided by the remote portal HVVg Ares only retrieves it Push Period Interval for sending the values in seconds Log Period Interval for logging records into memory in seconds Data are then transmitted together according to the configured Push Period The memory can hold up to 10 measurements Delta Temperature Difference in temperatures that triggers immediate da
30. to establish GPRS connection This information should not appear for more than 20 s Otherwise it indicates a modem fault see Troubleshooting February 2012 www HW group com page 14 HVVg Ares HVV group Configuring Internet Internet connection is being configured reading IP parameters Connected to Internet The modem is successfully connected to the Internet Terminating Internet Internet connection is being disconnected Terminate Connection to the mobile network was terminated This can appear when the device is being restarted switched off or when its battery is low Hanging Dial up connection is being hanged up Unknown state e Signal Quality GSM signal quality in dBm and as a percentage The percentage should be as high as possible If it is less than 50 we strongly suggest to relocate the antenna or use a different mobile carrier e Reg Operator Regional GSM carrier Indicates a successful connection to the GSM network and the actual carrier when roaming e FW version Current firmware version e Email Queue Number of outgoing e mails waiting in the queue e SMS Queue Number of outgoing text messages waiting in the queue Digital Inputs ID 8 External Power is a system entry that indicates connected disconnected external power supply It is used to inform about power failures and battery powered operation Sensors ID 65535 Battery monitor is a syst
31. ure alarm text message SMS recipients Each recipient phone number is also authorized to request information from Ares 12 by dialing the unit s phone number and to send SMS commands without a password see Advanced settings e Recipient 1 5 Phone numbers where to send alarm text messages SMS o Ring out Upon alarm dial the given number The phone rings for 15 seconds rings three times or until the callis refused e Report End of Alarm Users will be also informed when an alarm ends global setting e Alarm reminder Send reminders about active alarms o Period Period of alarm reminders in minutes o Template Template to use for the reminder message e Send Test SMS Send a test SMS to all configured numbers e Clean SMS Queue Clear all unsent text messages from the queue e Save Save all changes e Status SMS Settings Ares can send a text message with the current sensor states as a reply to an incoming STATUS message If the phone number where the status request originated is not listed among the recipients a password needs to be specified as well o Status SMS Password Password required to send the status message to a number not listed among alarm recipients Show password Displays the password in a readable form Template Template to use for the status message Send Status SMS if ring from one of the Alarm recipients Status message is sent whenever any of the alarm recipients calls the device