CG-500 - American Weigh Scales
Contents
1. AWS Arercan Weigh Scales Inc G Series CG 50 50x0 01g CG 800 500x019 USer Manual CG Series Manual Thank you for purchasing the American Weigh CG Series digital scale Please read all operating instructions carefully before use This electronic scale is a precision instrument With normal care and proper treatment it will provide years of reliable service Never load the scale with more than the maximum capacity Overloading will permanently damage it Avoid any exposure to extreme heat or cold Your scale works better when operated at normal room temperature Always allow the scale to acclimate to normal room temperature for at least one hour before use Give your scale sufficient warm up time Usually 30 60 seconds before calibration to give the internal components a chance to stabilize Keep your scale in a clean environment Dust dirt moisture vibration air currents and a close distance to other electronic equipment can all cause an adverse effect on the reliability and accuracy of your scale Handle with care Gently apply all items to be weighed onto tray top Although this scale is designed to be quite durable try to avoid rough treatment as this may permanently damage the internal sensor Avoid shaking dropping or otherwise shocking the scale This is a precision instrument and must be handled with extreme care Only operate the scale on a stable vibration free surface I OPERATION Place Scale on a h
2. inches 2 0 x 2 7 Stainless Steel Scale Dimensions inches 2 2x 3 5 x 0 9 Power 2 x CR2032 Batteries included Warranty 10 Year Warranty
3. ly The CG 500 calibrates with a 500g weight The CG 50 calibrates with a 50g weight Weights not included 1 Turn on the scale by pressing the ON OFF key 2 Wait until the LCD displays 0 0 or 0 00 then press and HOLD the MODE key for 3 seconds The LCD will display CAL You may now release the MODE key 3 Press the MODE key again The LCD will display CAL followed by the required calibration weight see above 4 Place the required calibration weight on the center of the platform The display will show PASS and return to normal weighing mode 5 Put away the calibration weight and press ON OFF to turn off the scale and the calibration is finished V TROUBLESHOOTING The primary reasons for inaccuracy or malfunction are low batteries incorrect calibration overload or operating on an unstable surface Please keep this in mind and maintain and operate your scale properly This scale is a precise instrument and must be handled with the utmost care and caution Display Elimination of errors OUT2 Recalibrate the scale Section Ill EEEE You are overloading the scale Remove the excessive load immediately un2T Use the scale in a more stable position Specifications CG 500 500 0g 17 640z 16 080zt 321 5dwt Resolution Weighing Units 0 1g 0 010z 0 010zt 0 1dwt g Oz ct gn Calibration Weight not Included 50g Platform Dimensions
4. orizontal flat surface 1 Press ON OFF key to turn the scale on 2 Wait until 0 0 or 0 00 is displayed 3 Place the object s onto the weighing platform 4 By pressing the MODE key you can switch between weighing units Il TARE WEIGHING 1 Turn on scale as described above 2 Place a tray or container on the scale platform 3 Press TARE and wait until 0 0 or 0 00 is displayed 4 You can now add items to the container or tray to obtain just the weight of the contents Ill COUNTING FEATURE 1 Turn on the scale and wait until the LCD displays 0 0 or 0 00 2 Place a sample quantity 25pcs 50pcs 75pcs or 100pcs of the items you want to count onto the platform 3 Press and HOLD the PCS key for 2 seconds the LCD will display the sample quantity setting for example 100 4 Press the MODE key to select the sample amount of the item which you placed onto the platform 5 Press the PCS key to confirm the above information the LCD will now display pcs in the corner to show that the scale is in counting mode 6 Remove the sample quantity from the platform 7 You now can place any amount of your item s on the scale and the LCD will display a count 8 You can switch between weighing mode and counting mode by pressing MODE or PCS key respectively IV CALIBRATION Calibration is NOT required before first use Only calibrate if the scale is not weighing proper
Download Pdf Manuals
Related Search
Related Contents
HPWH Service Handbook (321549 Impianti meccanici (appunti ufficiali Massi). Fujifilm FinePix F440 User's Manual Copyright © All rights reserved.
Failed to retrieve file