Home

Table of contents - Streckkod System AB

image

Contents

1. Battery is i near empty Press a key or put OPLITEB in cradle to charge 4 3 Battery empty Battery is i empty Put OFLIFZ8 in cradle to charge Battery is 4 empty Put OPLITEB in cradle to charge During operation a small amount of power is drained from the battery When the battery detects that the battery is nearly empty the near empty message is alerted The OPL9728 can be placed on the cradle to recharge the battery pack or press a key to continue operation When already the battery near empty message has been alerted and operation was continued the battery empty message could be alerted This message indicates that the battery needs to be recharged it is not possible to continue operation without recharging the battery When the OPL9728 has been placed in the cradle the battery charging image appears When the OPL9728 is picked from the cradle and the battery is not charged enough the battery empty message is alerted again Place the OPL9728 in the cradle to charge the battery further If the battery is enough charged after a battery empty message The application will start from the scan labels in the main menu SCAN QUANTITY DEMO OPL9728 OPTICON
2. Scan quantity demo application description Version LFD24390 for OPL9728 SCAN QUANTITY DEMO OPL9728 OPTICON CAUTION This user s manual may be revised or withdrawn at any time without prior notice Version User s manual for Graphical scanning quantity demo application of OPL9728 Version LFD24390 February 2003 Copyright 2002 Opticon Sensors Europe B V All rights reserved Limited warranty and disclaimers By opening the package of this product you agree to become bound by the liability and warranty conditions as described below Under all circumstances this manual should be read attentively before installing and or using the product In no event Opticon Sensors Europe will be liable for any direct indirect consequential or incidental damages arising out of use or inability to use both the hardware and software even if Opticon has been informed about the possibility of such damages All Opticon products are warranted for a period of one year after purchase covering defects in physical media and physical documentation The liability of Opticon is limited to replacement of defective media or documentation Opticon will not be liable for modifications that are made by the customer Opticon does not warrant that the software is free of errors or that it will meet any user s particular standards requirements or needs Opticon will in no event be liable for any direct indirect or incidental damages arising out of
3. the database is removed from the RAM disk and the application returns to the main menu SELECT SCAN QUANTITY DEMO OPL9728 OPTICON SCAN QUANTITY DEMO APPLICATION PAGE 15 2 5 Send data 3 By selecting the Send data menu the send data database if present can be transmitted to the PC The protocol and baudrate as set in the 2 communication menu are used The other communication parameters that can not be changed are Parity None Databits 8 Stopbits 1 Transmit data When the transmit data message appears on the display put the OPL9728 in the cradle and then press a key On the PC needs to run an application to receive the database OEA After a successful transmission a message appears to delete the database See delete data for more infromation x Transmission error during transfer protocol If this message appears transmission is interrupted Then retry to transmit the database to the PC SCAN QUANTITY DEMO OPL9728 OPTICON SCAN QUANTITY DEMO APPLICATION PAGE 16 2 6 Version 6 Selection the version menu item the current Vers 101 software version is shown E SOFTWARE WERSION The software version of this application LEO 4338 E AHY KEY SCAN QUANTITY DEMO OPL9728 OPTICON SCAN QUANTITY DEMO APPLICATION PAGE 17 3 Data format Each record is stored in a database file called DATA TXT The fields in a record are lt Barcode 50 chara
4. 1 back 3 2 2 16 enable barcode types 3 3 Communicate 3 3 1 back 3 3 2 Baudrate t 3 3 2 1 back 3 3 2 2 8 select baudrate 3 3 3 Protocol 3 3 3 1 back i 3 3 3 2 3 select protocol 3 4 Battery volt 3 5 Memory 3 6 Date time 3 7 Standby time 3 7 1 back 3 7 2 9 select standby time 3 8 Backlight Delete data Send data Version SCAN QUANTITY DEMO OPL9728 OPTICON SCAN QUANTITY DEMO APPLICATION PAGE 6 2 1 Scan Labels 1 scan labels lt a 1 scan labels 780123456786 Total H dd No data on RAM disk By pressing the trigger button the laser line emits and it is possible to scan a barcode Data present on RAM disk By pressing the trigger button the laser line emits and it is possible to scan more barcodes Barcode can now be scanned be pressing the trigger button Keyboard input is also possible To enter alpha data press the shift button en while keeping it pressed press any of the numeric keys To enter the input data press the ENT key To return to the main menu the G key or the CLR key can be pressed Data in display after scanning or entering a barcode The total value is the found quantity in the database If the entered data does not exist in the database the total value is 0 The value within the rectangle is the default value Any numeric input smaller then 4 digits could overwrite the default value To input a negative value keep the 6 pres
5. cters right padded with spaces gt lt Quantity 7 characters left padded with spaces 6 numeric and 1 sign bit gt lt Time stamp 8 characters format HH MM SS gt lt Date stamp 10 characters format DD MM YYYY gt The fields in record are separated by a comma and all records end with a lt CR gt lt LF gt character A Complete record looks like this lt Barcode gt lt Quantity gt lt Time gt lt Date gt lt CR gt lt LF gt The maximum amount of record that can be placed in this terminal is almost 6500 records SCAN QUANTITY DEMO OPL9728 OPTICON SCAN QUANTITY DEMO APPLICATION PAGE 18 4 Battery 4 1 Battery charging a If the OPL9728 with the battery pack is placed in the cradle the voltage and the required loading time is automatically determined During charging the OPL9728 shows one of the images on the left Also the RED led on the terminal will emit When the battery is fully charged the led will be GREEN and the image on the left will be 00 Y shown The voltage meter shows the voltage 4 86 Y on the contacts of the battery E4 Note e When sending data transmission battery will also be charged The led will emit RED or GREEN but the charging image is not displayed SCAN QUANTITY DEMO OPL9728 OPTICON SCAN QUANTITY DEMO APPLICATION PAGE 19 4 2 Battery near empty Battery is a near empty Press a key or put DPLITES in cradle to charge
6. ime or date The new settings are not saved when the error message is signaled SCAN QUANTITY DEMO OPL9728 OPTICON SCAN QUANTITY DEMO APPLICATION PAGE 13 3 7 Selecting the standby time sets the time the Standby time terminal stays on when no key is pressed E When pressing one of the three keys will turn the terminal back on _ 3 3 The backlight menu controls the way the Back light OPL9728 uses the backlight The Baclight menu options are OFF ON and AUTO When the auto option is selected then when a key is pressed the backlight of the display will stay on for 10 seconds Mi chacra selected backlight item O Unchecked unselected backlight item By selecting a new backlight item the previous selected item is unselected SCAN QUANTITY DEMO OPL9728 OPTICON SCAN QUANTITY DEMO APPLICATION PAGE 14 2 4 Delete data 4 When no data is available the option select Delete data will result in a message that there is no data A on the RAM disk When selecting this menu item it is possible to De lete data delete the inputted data The default screen when delete data is selected and data is available This screen will also appear when a successful send data data transmission occurs When cancel is selected the database is not removed from the RAM disk DELETE DATA Use button G or P to switch between delete and cancel When the delete option is DELETE selected
7. is disabled The protocol menu enables the protocol that will be used to send data There are two protocols available The No protocol sending data from the database as flat ascii The NetO protocol sending data to the PC by the NetO protocol M checked protocol enabled E Unchecked protocol disabled By selecting a new protocol the previous selected protocol is disabled The battery voltage menu shows the current input voltage of the battery SCAN QUANTITY DEMO OPL9728 OPTICON SCAN QUANTITY DEMO APPLICATION PAGE 12 Memory 3 5 3 6 Date time Wednesday 26 46 2042 14 25 48 The memory menu shows the amount of free memory on the RAM disk When the message that the RAM disk is almost full appears then a small amount of memory is still free The still available free memory is needed by data communication from the Send data menu RAM disk is almost full data is stored A RAM disk is full data is not stored The date time menu item shows the current day date and time Use button A BACK to return to the system menu Use button E2 SET to change the time and date Use button aG and E2 to navigate Use E button to change the value where the cursor is positioned When the cursor is placed under the E of End the new time and date can be saved If the newly entered time or date is not a correct value an error message is signaled x Error in setting T
8. l options can be viewed or set The navigation of this menu is the same as navigating the main menu 3 System menu 3 1 hack EXIT A E EACE The system menu consist of 8 items back Barcodes Communicate Battery volt Memory Date time Standby time Backlight When the back menu item is selected the application returns to the main menu SCAN QUANTITY DEMO OPL9728 OPTICON SCAN QUANTITY DEMO APPLICATION PAGE 10 3 2 Barcodes TeS i The barcode menu enables or disables barcode types that are supported by the OPL9728 More barcodes can be enabled at the same time Mf checked enabling barcode E Unchecked disabling barcode Supported barcode types are Code 39 EAN UPC Interleaved 2 of 5 Industrial 2 of 5 Codabar Code 93 Code 128 MSI plessey Telepen UK plessey IATA Scode Matrix 2of5 All Addons By enabling all addons the addons for all supported barcode types are enabled SCAN QUANTITY DEMO OPL9728 OPTICON SCAN QUANTITY DEMO APPLICATION PAGE 11 3 3 Communicate 10101 3 32 Baudrate f 4 3 3 Protocol 3 4 Battery volt i With the communicate menu the baudrate and protocol can be set The baudrate menu enables or disables one baudrate Macs baudrate enabled O Unchecked baudrate disabled By selecting a new baudrate the previous baudrate
9. ntity that is stored in the database can be changed Changing the quantity happens the same way as the add quantity input The default value is the value that is stored in the database If the default value is changed to a new value this message appears on the display a enables the new input value and stores it in the database cancels the input the dtabase keeps unchanged SCAN QUANTITY DEMO OPL9728 OPTICON SCAN QUANTITY DEMO APPLICATION PAGE 8 2 2 Scroll data IN Are you sure you want to remowe the record from the database Eri L Z scroll data scroll data 10 25 48 20702720H Before deleting the record this message appears If the question is acknowledged G The record will be removed from the database this action cannot be undone When E2 is pressed the record will not be deleted When no data is available the option select will result in a message that there is no data on the RAM disk When selecting this menu item it is possible to scroll through the inputted data To navigate through the inputted data use the G and E2 keys When pressing the 4 and G the first record in the database is displayed amp and E2 will display the last record of the database SCAN QUANTITY DEMO OPL9728 OPTICON SCAN QUANTITY DEMO APPLICATION PAGE 9 2 3 System menu The System menu contains a submenu where special termina
10. sed and press the To make a negative value positive repeat the same process To enter the input press the ENT or trigger key If the Total Add quantity is O zero the record is deleted from the database SCAN QUANTITY DEMO OPL9728 OPTICON SCAN QUANTITY DEMO APPLICATION PAGE 7 Walid value Quant ity exceeding max input value value not stored SCAN BARCODE 780123456786 Juant i OPTIONS BARCODE OPTIONS CHANGE QUANTITY 9700131456706 Quant Neu EXE Are you sure IN you want to store the new oe ity 1 If the entered quantity is not a valid value this message box will appear By pressing any key the OPL9728 returns to the quantity input A 0 zero is a valid input then the changes are not stored in the database If the total quantity in the database with the newly added quantity exceeds 999999 or 999999 then this message appears The added quantity is stored in the database After pressing a key the scan barcode menu appears After entering the quantity the application returns to the scan barcode Shown on screen is now the previous scanned barcode with the quantity in the database Pressing the Q2 key will open a special menu item that can perform some operations on the previous scanned barcode G will return to the scan barcode menu deletes this record item from the database By pressing the ae button the qua
11. use of this software Trademarks used are property of their respective owners SCAN QUANTITY DEMO OPL9728 OPTICON TABLE OF CONTENTS 3 Table of contents TABLE OF CONTENTS 1 KEYS 2 THE MENU STRUCTURE 2 1 Scan Labels 2 2 Scroll data 2 3 System menu 2 4 Delete data 2 5 Send data 2 6 Version 3 DATA FORMAT 4 BATTERY 4 1 Battery charging 4 2 Battery near empty 4 3 Battery empty SCAN QUANTITY DEMO OPL9728 OPTICON O 0 a 14 16 17 18 18 19 19 SCAN QUANTITY DEMO APPLICATION PAGE 4 1 Keys The OPL9728 has full numeric keypad with some additional control keys The Q1 key Up key or with shift left key The Trigger key The Q2 key Down key or with shift right key While holding the shift key and pressing a numeric key the alpha representative value is displayed on the screen SCAN QUANTITY DEMO OPL9728 OPTICON SCAN QUANTITY DEMO APPLICATION PAGE 5 2 The Menu structure The menu structure consists of several menu items These items together form the Main and submenus To navigate through the menu s the G and E2 keys can be used Item from the menu can be selcted by pressing the ENT or the EE button Direct selection of the menu is also possible by pressing the numeric equivalent of the menu item Below is the schematic representation of the menu that is displayed in the OPL9728 1 Scan labels 2 Scroll data 3 System menu 3 1 back 3 2 Barcode 3 2

Download Pdf Manuals

image

Related Search

Related Contents

G1 Charger  User Manual      

Copyright © All rights reserved.
Failed to retrieve file