Home

CL1Y2-T1D2S CC-Link/LT Remote I/O Module User`s Manual

image

Contents

1. Country Region Sales office Tel Mitsubishi Electric Automation Hong Kong Ltd 10th Floor Manulife Tower 169 Electric Road North Point HongKong Tel 852 2887 8870 Mitsubishi Electric Automation Shanghai Ltd 17F ChuangXing Financial Center No 288 West Nanjing Road Shanghai China 200003 Tel 86 21 2322 3030 Setsuyo Enterprise Co Ltd 6F No 105 Wu Kung 3rd RD Wu Ku Hsiang Taipei Hsien 248 Taiwan Tel 886 2 2299 2499 Mitsubishi Electric Automation Korea Co Ltd 3F 1480 6 Gayang Dong Gangseo Gu Seoul 157 200 Korea Tel 82 2 3660 9552 Mitsubishi Electric Asia Pte Ltd 307 Alexandra Road 05 01 02 Mitsubishi Electric Building Singapore 159943 Tel 65 6470 2460 Mitsubishi Electric Automation Thailand Co Ltd Bang Chan Industrial Estate No 111 Soi Serithai 54 T Kannayao A Kannayao Bangkok 10230 Tel 66 2 517 1326 Messung Systems Pvt Ltd Sapphire House EL 3 J Block MIDC Bhosari Pune 411026 India Tel 91 20 27102000 Mitsubishi Electric Australia Pty Ltd 348 Victoria Road Rydalmere N S W 2116 Australia Tel 61 2 9684 7777 Circuit Breaker Industries Ltd Private Bag 2016 ZA 1600 Isando South Africa Tel 27 11 9282000 MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN HIMEJI WORKS 840 CHIYODA CHO HIMEJI JAPAN Specifications subject to change without notice
2. DISPOSAL PRECAUTIONS lt gt DANGER e When disposing of this product treat it as industrial waste TRANSPORTATION AND MAINTENANCE PRECAUTIONS CAUTION e During transportation avoid any impact as the module is a precision instrument Doing so could cause trouble in the module e If is necessary to check the operation of module after transportation in case of any impact damage Notification of CE marking This notification does not guarantee that an entire mechanical module produced in accordance with the contents of the notification comply with the following standards Compliance to EMC standards of the entire mechanical module should be checked by the user manufacturer Standards with which this product complies Type Programmable Controller Open Type Equipment Remote I O module Models Products manufactured from November 1st 2002 to April 30th 2006 are compliant with EN61000 6 4 and EN61131 2 1994 A11 1996 A12 2000 after May 1st 2006 are compliant with EN61131 2 2003 Electromagnetic Compatibility Standards EMC EN61000 6 4 2001 Electromagnetic compatibility Compliance with all relevant aspects of the standard Generic standards Emission standard for Industrial environment EN61 131 2 1994 A11 1996 A12 2000 Programmable controllers Equipment requirements and tests EN61131 2 2003 Programmable controllers Equipment requirements and tests For more details please contact the loc
3. Side B X JAPANESE VB ENGLISH MITSUBISHI cose ror ime sener CL1Y2 T1D2S CC Link LT Remote I O Module Please read this manual thoroughly before starting to use the product and handle the product properly User s Manual MODEL CL1Y2 T1D2S MANUAL Number JY997D04001F September 2008 CCink LT SAFETY PRECAUTIONS Read these precautions before using Please read this manual carefully and pay special attention to safely in order to handle this product properly Also pay careful attention to safely and handle the module properly These precautions apply only to Mitsubishi equipment Refer to the user s manual of the CPU module to use for a description of the PLC system safety precautions These SAFETY PRECAUTIONS classify the safety precautions into two categories DANGER and CAUTION properly lt gt DANGER Procedures which may lead to a dangerous condition CAUTION and cause superficial to medium injury or physical damage only if not carried out properly Depending on circumstances procedures indicated by Z CAUTION may also be linked to serious results In any case it is important to follow the directions for usage Procedures which may lead to a dangerous condition and cause death or serious injury if not carried out Store this manual in a safe place so that you can take it out and read it whenever necessary Always forward it to the end user DESIGN PRECAUTIONS e Configure
4. 0 79 je 500 1 9 69 Dy COMM J MELSEG CL1Y2 T1D2S 65 2 56 S STATION wg 4 Hozotos 4 2 11T Bo Bo OUT 24G YO Y1 24V yf 500 19 69 Unit mm inches a DOCG This manual confers no industrial property rights or any rights of any other kind nor does it confer any patent licenses Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi machine damage or lost profits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties For safe use e This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life Before using the product for special purposes such as nuclear power electric power aerospace medicine or passenger movement vehicles consult with Mitsubishi e This product has been manufactured under strict quality control However when installi
5. 500mm 19 69 flat cable dedicated to CC Link LT and 500mm 19 69 flat cable for I O Noise durability Isolation resistance 6 Outside Dimensions 20 0 79 J 500 1 9 69 COMM MELSEC CL1Y2 T1D28 65 2 56 SI STATION NOJO par 4 po2010 8 4 2 11T D EE _500 19 69 12 0 48 Unit mm inches This manual confers no industrial property rights or any rights of any other kind nor does it confer any patent licenses Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi machine damage or lost profits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties For safe use e This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life e Before using the product for special purposes such as nuclear power electric power aerospace medicine or passenger movement veh
6. OFF Clears the output 3 Cautions on Handling 3 1 Handling of flat cable for I O The cable length from the module to a sensor shall be within 3m 9 10 Measure the cable outside the module and confirm that the driving voltage for the used sensor is assured e Output Crimp style connection device with insulator or closed end connection device Lamp F A solenoid etc gt g If the diameter of the output equipment connection cable is equivalent to the diameter of the flat cable for I O of this module connectors dedicated to CC Link LT can be used for connection Connector dedicated to CC Link LT ger Ny Output equipment 24G YO Y1 24V Output N equipment Wire diameter AWG18 34 0 18 3 2 Handling of cable Do not bend the cable within 30mm 1 19 from the module 30mm 1 19 30mm 1 19 a as Use a crimp style terminal in a status in which no force is applied on the cable 3 3 Mounting with the CL1 HLD module holder Refer to the figures below for details on mounting or removing the remote I O module when used with the CL1 HLD Mount Dismount CL1 HLD 1 Fit the remote I O module in b gt a corner of the CL1 HLD 2 Press down b Remote while holding a module a gt 1 Insert a screwdriver into either a b orc 2 Pry the remote I O module from the holder using the screwdriver 6 Outside Dimensions 20
7. of conductive generating substances in the environment in which the module is used The degree of contamination 2 indicates that contamination is caused by generation of only non conductive substances In this degree however temporary conduction may be caused by accidental condensation 5 2 Output specifications Specification Transistor output using module power supply in common sink Isolation with photocoupler 24V DC Same as module power supply Output method Number of outputs Isolation method Rated load voltage Operating load voltage range Max load current 0 1A point 0 2 A 1 common 0 4A 10 ms Max inrush current 0 1mA or less 30V DC 1V or less max 0 1A Response time 2 point 1 common 1 point Internal protection circuit none Please connect the fuse in the connected load outside Internal protection for outputs 5 3 Performance specifications Voltage Specification 20 4 to 28 8V DC 24V DC 15 to 20 Ripple ratio Within 5 Current 40mA when all points are ON consumption Max allowable momentary power PS1 ims failure period umber gfstationi 4 8 or 16 point mode 1 station occupied 500Vp p Noise width 1us Cycle 25 to 60 Hz by noise simulator Withstand voltage 500V AC for 1 min 10 MQ or more between primary area external DC terminal and secondary area internal circuit by 500V DC megger I O part connection method 0 07 kg 0 15 Ibs including
8. 0 6 4 2001 Electromagnetic compatibility Generic standards Emission standard for Industrial environment EN61 131 2 1994 A11 1996 A12 2000 Programmable controllers Equipment requirements and tests Compliance with all relevant aspects of the standard Radiated Emissions and Mains Terminal Voltage Emissions Compliance with all relevant aspects of the standard RF Immunity Fast transients ESD and Damped oscillatory wave Compliance with all relevant aspects of the standard Radiated Emissions Mains Terminal Voltage Emissions RF immunity Fast Transients ESD Surge Voltage drops and interruptions Conducted and Power magnetic fields For more details please contact the local Mitsubishi Electric sales site Notes For compliance to EMC regulation It is necessary to install the CL1 series module in a shielded metal control panel EN61131 2 2003 Programmable controllers Equipment requirements and tests 5 Specifications 5 1 General specifications Specification Number of times of When intermittent vibration is present sweep Frequency Half amplitude 10to 57Hz 0 075mm 57 to 150HZ 10 times in each of When continuous vibration is present X Y and Z directions Frequency Half amplitude for 80 min 10 to 57Hz 0 035mm 57 to 150Hz mpari 147 m s2 3 times in each of X Y and Z directions resistance operating Corrosive gas shall not be present atmosphere Operatin
9. No in the range from 1 to 64 Example When setting the station No to 32 set the DIP switch as follows Station Po a ead 32 OFF 32 OFF OFF OFF ON OFF 5 2 Output specifications em O Specification Transistor output using module power supply in common sink Number of outputs Isolation method Isolation with photocoupler Output method Rated load voltage 24V DC Operating load voltage range Max load current 0 1A point 0 2 A 1 common Same as module power supply 0 1mA or less 30V DC 1V or less max 0 1A Response ime Internal protection circuit none Please connect the fuse in the connected load outside Internal protection for outputs 5 3 Performance specifications Specification 20 4 to 28 8V DC 24V DC 15 to 20 Voltage Ripple ratio Within 5 consumption Max allowable momentary power PS1 1ms failure period numana of stations 4 8 or 16 point mode 1 station occupied 500Vp p Noise width 1us Cycle 25 to 60 Hz by noise simulator Withstand voltage 500V AC for 1 min 10 MQ or more between primary area external DC terminal and secondary area internal circuit by 500V DC megger co 0 07 kg 0 15 Ibs including 500mm 19 69 flat cable dedicated to CC Link LT and 500mm 19 69 flat cable for I O Noise durability Isolation resistance Description Holds the output when an error has occurred HLD ON Holds the output
10. Side B X JAPANESE VB ENGLISH MITSUBISHI cose ror ime sener CL1Y2 T1D2S CC Link LT Remote I O Module Please read this manual thoroughly before starting to use the product and handle the product properly User s Manual MODEL CL1Y2 T1D2S MANUAL Number JY997D04001F CCink LT SAFETY PRECAUTIONS Read these precautions before using Please read this manual carefully and pay special attention to safely in order to handle this product properly Also pay careful attention to safely and handle the module properly These precautions apply only to Mitsubishi equipment Refer to the user s manual of the CPU module to use for a description of the PLC system safety September 2008 categories DANGER and CAUTION properly Depending on circumstances procedures indicated by Z CAUTION precautions Procedures which may lead to a dangerous condition lt gt DANGER Procedures which may lead to a dangerous condition may also be linked to serious results These SAFETY PRECAUTIONS classify the safety precautions into two and cause death or serious injury if not carried out CAUTION and cause superficial to medium injury or physical damage only if not carried out properly In any case it is important to follow the directions for usage Store this manual in a safe place so that you can take it out and read it whenever necessary Always forward it to the end user DESIGN PRECAUTIONS e Configure an int
11. al Mitsubishi Electric sales site Notes For compliance to EMC regulation It is necessary to install the CL1 series module in a shielded metal control panel Radiated Emissions and Mains Terminal Voltage Emissions Compliance with all relevant aspects of the standard RF Immunity Fast transients ESD and Damped oscillatory wave Compliance with all relevant aspects of the standard Radiated Emissions Mains Terminal Voltage Emissions RF immunity Fast Transients ESD Surge Voltage drops and interruptions Conducted and Power magnetic fields 1 Outline of Product This product is a cable type output module connected to CC Link LT This product has two output points transistor output Connector dedicated to CC Link LT sold separately Output equipment Flat cable dedicated to CC Link LT Switch cover Make sure to attach the switch cover after setting the DIP switch Attach it with this area facing upward a DIP switch Remove the switch cover when setting the DIP switch DIP switch assignment 402010 8 4 2 1HLD f SSA onno 4 ko2010 8 42 11E U lt 4 oOoO0o0o0O PWLRUN E I 24G YO Y1 24V _ Status indicator LEDs Output operation indicator LED Output is ON Lit Output is OFF Extinguishe
12. an interlock circuit in a sequence program so that the system operates on the safety side using the communication status information in the event the data link falls into a communication problem Otherwise erroneous output and malfunction may result in accidents e Remote input and output can not be switched ON or OFF when a problem occurs in the remote I O modules Therefore build an external monitoring circuit that will monitor any input signals that could cause a serious accident e Do not have control cables and connection cables bundled with or placed near by the main circuit and or power cables Wire those cables at least 100mm 3 94 inch away from the main circuit and or power cables It may cause malfunction due to noise interference e Use the module in the status in which any force is not applied on the module flat cables dedicated to CC Link LT and flat cables for I O If a force is applied wire breakage or failure may be caused INSTALLATION PRECAUTIONS e Use the module in an environment that meets the general specifications contained in this manual Using this module in an environment outside the range of the general specifications could result in electric shock fire erroneous operation and damage to or deterioration of the product e Do not directly touch the module s conductive parts Doing so could cause malfunction or trouble in the module WIRING PRECAUTIONS e Perform installation and wiring after disconn
13. d LED name Operation PW Lit while the power is supplied Lit while normal operation is executed Blue White Flat cable for I O Black Brown Status indicator ON while the power is supplied L RUN ON while normal operation is executed ON while the output is ON Extinguished while the output is OFF O YO output operation Y1 output operation indicator LED indicator LED dedicated to CC Link LT Flat cable for I O Set the 10 s digit of the station No using STATION NO 10 STATION NO 20 and STATION NO 40 Set the 1 s digit of the station No using STATION NO 1 STATION NO 2 STATION NO 4 and STATION NO 8 Factory default All bits are OFF DIP switch Make sure to set the station No in the range from 1 to 64 Example When setting the station No to 32 set the DIP switch as follows Station No 40 20 10 8 4 2 1 Description Holds the output when an error has occurred HLD ON Holds the output OFF Clears the output 3 Cautions on Handling 3 1 Handling of flat cable for I O The cable length from the module to a sensor shall be within 3m 9 10 Measure the cable outside the module and confirm that the driving voltage for the used sensor is assured e Output Crimp style connection device with insulator or closed end connection device Lamp F A solenoid etc gt g If the diameter of the ou
14. e Branch Ria e ia Ctra de Rub 76 80 AC 420 E 08190 Sant Thailand ee Electric Automation Thailand Cugat de Valles Sarcolong Spain Bang Chan Industrial Estate No 111 Tel 34 93 565 3131 Soi Serithai 54 T Kannayao A Kannayao France Mitsubishi Electric Europe B V French Bangkok 10230 Branch Tel 66 2 517 1326 Ri pauls ge Bouvets F 92741 India Messung Systems Pvt Ltd anterre Cadex France Sapphire House EL 3 J Block MIDC l Tal ranna a Bhosari Pune 411026 India Russia Mitsubishi Electric Europe B V Moscow Tel 91 20 27102000 Representative Office Australia Mitsubishi Electric Australia Pty Ltd 52 bld 5 Kos modamianskaya nab 348 Victoria Road Rydalmere N S W RU 115054 Moscow Russia 2116 Australia Tel 7 495 721 2070 Tel 61 2 9684 7777 South Africa Circuit Breaker Industries Ltd Private Bag 2016 ZA 1600 Isando South Africa Tel 27 11 9282000 aMITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN HIMEJI WORKS 840 CHIYODA CHO HIMEJI JAPAN Specifications subject to change without notice
15. ecting the power supply at all phases externally If the power is not disconnected at all phases an electric shock or product damage may result 4 Wiring 4 1 External wiring The output terminals of the CL1Y2 T1D2S operate while using the power supplied from the interface The output wiring is fixed to the sink output Output wiring CL1Y2 T1D2S Flat cable dedicated Isolation Flat cable to CC Link LT DCDC 0 5A LH Internal L circuit e Perform correct wiring for the module according to the product s rated voltage and terminal arrangement Connecting to a power supply different from rating or miss wiring may cause fire product failure or malfunction e Make sure foreign objects do not get inside the module such as dirt and wire chips It may cause fire product failure or malfunction e Do not short circuit the 24G and 24V terminals It may result in fire product failure or malfunction e Attach a warning label hazard symbol 417 IEC 5036 concerning the electric shock to the location STARTING AND MAINTENANCE PRECAUTIONS e Do not touch the terminals when the power is ON It may cause an electric shock or malfunction e Perform cleaning the module after turning OFF the all external power supply for sure Failure to do so may cause failure or malfunction of the mod
16. erlock circuit in a sequence program so that the system operates on the safety side using the communication status information in the event the data link falls into a communication problem Otherwise erroneous output and malfunction may result in accidents e Remote input and output can not be switched ON or OFF when a problem occurs in the remote I O modules Therefore build an external monitoring circuit that will monitor any input signals that could cause a serious accident e Do not have control cables and connection cables bundled with or placed near by the main circuit and or power cables Wire those cables at least 100mm 3 94 inch away from the main circuit and or power cables It may cause malfunction due to noise interference e Use the module in the status in which any force is not applied on the module flat cables dedicated to CC Link LT and flat cables for I O If a force is applied wire breakage or failure may be caused INSTALLATION PRECAUTIONS e Use the module in an environment that meets the general specifications contained in this manual Using this module in an environment outside the range of the general specifications could result in electric shock fire erroneous operation and damage to or deterioration of the product e Do not directly touch the module s conductive parts Doing so could cause malfunction or trouble in the module WIRING PRECAUTIONS e Perform installation and wiring after disconnect
17. g a altitude 2 000m 6561 8 or less 1 natalation Inside control panel 2 place Over voltage II or less 3 category pediee ora 2 or less 4 contamination Notes 1 The module cannot be used in an environment pressurized above the atmospheric pressure which can be generated around the altitude of O m If the module is used in such an environment it may fail 2 The module can be used in any environment even outside the control panel as far as the requirements of the ambient operating temperature the ambient operating humidity etc are satisfied 3 This indicates the section of the power supply to which the equipment is assumed to be connected between the public electrical power distribution network and the machinery within premises Category II applies to equipment for which electrical power is supplied from fixed facilities The surge voltage withstand level for up to the rated voltage of 300V is 2500V 4 This index indicates the degree of conductive generating substances in the environment in which the module is used The degree of contamination 2 indicates that contamination is caused by generation of only non conductive substances In this degree however temporary conduction may be caused by accidental condensation 1 Outline of Product This product is a cable type output module connected to CC Link LT This product has two output points transistor output Connector dedicated to CC Li
18. icles consult with Mitsubishi e This product has been manufactured under strict quality control However when installing the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the system Country Region Sales office Tel U S A Mitsubishi Electric Automation Inc 500 Corporate Woods Parkway Vernon Hills IL 60061 U S A Tel 1 847 478 2100 Brazil MELCO TEC Av Paulista 1439 conj 74 Bela Vista CEP China 01311 200 Sao Paulo SP Brazil Tel 55 11 3285 1840 Mitsubishi Electric Europe B V German Branch Gothaer Strasse 8 D 40880 Ratingen Germany Tel 49 2102 486 0 U K Mitsubishi Electric Europe B V UK Branch Hong Kong Germany Taiwan Travellers Lane Hatfield Hertfordshire Korea AL10 8XB U K Tel 44 1707 276100 Italy Mitsubishi Electric Europe B V Italian Branch VIALE COLLEONI 7 20041 Agrate Brianza Milano Italy Tel 390 39 60531 Spain Mitsubishi Electric Europe B V Spanish Branch Ctra de Rub 76 80 AC 420 E 08190 Sant Cugat del Valles Barcelona Spain Tel 34 93 565 3131 Mitsubishi Electric Europe B V French Branch 25 Boulevard des Bouvets F 92741 Nanterre Cedex France Tel 33 1 55685568 Mitsubishi Electric Europe B V Moscow Representative Office 52 bld 5 Kos modamianskaya nab RU 115054 Moscow Russia Tel 7 495 721 2070 Singapore Thailand France India Russia Australia South Africa
19. ing the power supply at all phases externally If the power is not disconnected at all phases an electric shock or product damage may result CAUTION e Perform correct wiring for the module according to the product s rated voltage and terminal arrangement Connecting to a power supply different from rating or miss wiring may cause fire product failure or malfunction e Make sure foreign objects do not get inside the module such as dirt and wire chips It may cause fire product failure or malfunction e Do not short circuit the 24G and 24V terminals It may result in fire product failure or malfunction e Attach a warning label hazard symbol 417 IEC 5036 concerning the electric shock to the location STARTING AND MAINTENANCE PRECAUTIONS lt gt DANGER e Do not touch the terminals when the power is ON It may cause an electric shock or malfunction e Perform cleaning the module after turning OFF the all external power supply for sure Failure to do so may cause failure or malfunction of the modules CAUTION e Do not disassemble or modify the module Doing so may cause failure malfunction injury or fire e The module case is made of resin do not drop it or subject it to strong shock A module damage may result e Make sure to switch all phases of the external power supply OFF before installing or removing the module to from the panel Failure to do so may cause failure or malfunction of the modules
20. ions Specification Number of times of When intermittent vibration is present sweep Frequency Half amplitude 10to57Hz 0 075mm 57 to 150Hz 9 8m s2 When continuous vibration is present Frequency Half amplitude 10to57Hz 0 035mm 57 to 150Hz 4 9m s2 impact 147 m s2 3 times in each of X Y and Z directions resistance Operating Corrosive gas shall not be present atmosphere Operating ii 7 altitude 2 000m 6561 8 or less 1 Histevellen Inside control panel 2 place Over voltage II or less 3 category peatee orn 2 or less 4 contamination Notes 10 times in each of X Y and Z directions for 80 min 1 The module cannot be used in an environment pressurized above the atmospheric pressure which can be generated around the altitude of O m If the module is used in such an environment it may fail 2 The module can be used in any environment even outside the control panel as far as the requirements of the ambient operating temperature the ambient operating humidity etc are satisfied 3 This indicates the section of the power supply to which the equipment is assumed to be connected between the public electrical power distribution network and the machinery within premises Category II applies to equipment for which electrical power is supplied from fixed facilities The surge voltage withstand level for up to the rated voltage of 300V is 2500V 4 This index indicates the degree
21. ng the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the system Country Region Sales office Tel U S A Mitsubishi Electric Automation Inc 500 Corporate Woods Parkway Vernon Hills IL 60061 U S A Tel 1 847 478 2100 Brazil MELCO TEC Av Paulista 1439 conj 74 Bela Vista CEP China 01311 200 Sao Paulo SP Brazil Tel 55 11 3285 1840 Country Region Sales office Tel Hong Kong Mitsubishi Electric Automation Hong Kong Ltd 10th Floor Manulife Tower 169 Electric Road North Point HongKong Tel 852 2887 8870 Mitsubishi Electric Automation Shanghai Ltd 17F ChuangXing Financial Center Germany Mitsubishi Electric Europe B V German aa BE AE Nanjing Road Shanghai Branch ina Gothaer Strasse 8 D 40880 Ratingen Tel 86 21 2322 3030 Germany Taiwan Setsuyo Enterprise Co Ltd Tel 49 2102 486 0 6F No 105 Wu Kung 3rd RD Wu Ku U K Mitsubishi Electric Europe B V UK Helang Taipei A Taiwan Branch el 2 g Travellers Lane Hatfield Hertfordshire Korea ao Electric Automation Korea Co AL10 8XB U K Tel 44 1707 276100 3F 1480 6 Gayang Dong Gangseo Gu Italy Mitsubishi Electric Europe B V Italian Esa ert Koma Praneh Singapore Mitsubishi Electric Asia Pte Ltd VIALE COLLEONI 7 20041 Agrate Brianza 307 Alexandra Road 05 01 02 See eee Mitsubishi Electric Building Spain Mitsubishi Electric Europe B V Spanish Sgapar he e
22. nk LT sold separately Output equipment Flat cable dedicated to CC Link LT Switch cover Make sure to attach the switch cover after setting the DIP switch Attach it with ies area facing DIP switch Remove the switch cover when setting the DIP switch DIP switch assignment 4020108 4 2 1HLD upward a f SSA onno 4 ko2010 8 42 11E U lt 4 oOoO0o0o0O PWLRUN E I 24G YO Y1 24V _ Status indicator LEDs Output operation indicator LED Output is ON Lit Output is OFF Extinguished LED name Operation PW Lit while the power is supplied Lit while normal operation is executed Flat cable for I O e Blue White Black Brown a Status indicator ON while the power is supplied L RUN ON while normal operation is executed ON while the output is ON Extinguished while the output is OFF O YO output operation Y1 output operation indicator LED indicator LED Flat cable for I O Set the 10 s digit of the station No using STATION NO 10 STATION NO 20 and STATION NO 40 Set the 1 s digit of the station No using STATION NO 1 STATION NO 2 STATION NO 4 and STATION NO 8 Factory default All bits are OFF DIP switch Make sure to set the station
23. tput equipment connection cable is equivalent to the diameter of the flat cable for I O of this module connectors dedicated to CC Link LT can be used for connection Connector dedicated to CC Link LT ger Ny Output equipment 24G YO Y1 24V Output N equipment Wire diameter AWG18 34 0 18 3 2 Handling of cable Do not bend the cable within 30mm 1 19 from the module 30mm 1 19 30mm 1 19 amen T Use a crimp style terminal in a status in which no force is applied on the cable 3 3 Mounting with the CL1 HLD module holder Refer to the figures below for details on mounting or removing the remote I O module when used with the CL1 HLD Mount Dismount CL1 HLD 1 Fit the remote I O module in a corner of the CL1 HLD 2 Press down b while holding a b gt Remote module a 1 Insert a screwdriver into either a b orc 2 Pry the remote I O module from the holder using the screwdriver 4 Wiring 4 1 External wiring The output terminals of the CL1Y2 T1D2S operate while using the power supplied from the interface The output wiring is fixed to the sink output Output wiring CL1Y2 T1D2S Flat cable isolati dedicated Soia cae Flat cable to CC Link LT DCDC for VO 9 aa L T i Internal circuit 5 Specifications 5 1 General specificat
24. ules e Do not disassemble or modify the module Doing so may cause failure malfunction injury or fire e The module case is made of resin do not drop it or subject it to strong shock A module damage may result e Make sure to switch all phases of the external power supply OFF before installing or removing the module to from the panel Failure to do so may cause failure or malfunction of the modules DISPOSAL PRECAUTIONS lt gt DANGER e When disposing of this product treat it as industrial waste TRANSPORTATION AND MAINTENANCE PRECAUTIONS e During transportation avoid any impact as the module is a precision instrument Doing so could cause trouble in the module e If is necessary to check the operation of module after transportation in case of any impact damage Notification of CE marking This notification does not guarantee that an entire mechanical module produced in accordance with the contents of the notification comply with the following standards Compliance to EMC standards of the entire mechanical module should be checked by the user manufacturer Standards with which this product complies Type Programmable Controller Open Type Equipment Remote I O module Models Products manufactured from November 1st 2002 to April 30th 2006 are compliant with EN61000 6 4 and EN61131 2 1994 A11 1996 A12 2000 after May 1st 2006 are compliant with EN61131 2 2003 Electromagnetic Compatibility Standards EMC EN6100

Download Pdf Manuals