Home
Installation and Operation Guide
Contents
1. X 36 Control Panel Operation x ccc cece eee cece eee eeeeenenes 36 Router Configuration 0 ccc ccc eee cece e eee Hh es 36 Mode SCICCUON soupe van uet ew qd od NUT PER Og doctr V adeb caian 36 Buton setings A UnA ns zm din oi er d Nr AA Icom udi mee awe 37 NetWor Set De cacareado 38 Firmware Updating ccc ccc ccc eee cece eee e eee E 38 Unpackthe SOF Wal Gase tem pe qi auda eas usd Deu IMS uds Ur qd utt ita 39 Uploading and Installing Firmware to KUMO 0c cece eee eee ee 39 SAE DOO el 1 CNE OO POP anaes O dI EIUS 41 KUMOA 41 Locating a Specific KUMO us corrida a IOWA D b 42 Chapter 4 KUMO Remote Control Panel 43 Connectors and Indicator cece ccc cece eee eee enn 43 BUTTON Rey Caps cconcecaueesseasecssesacemenee E E EEEE 44 Panel Function Buttons ccc cece cece eee eee hehe 44 E AO A E E E E 44 Destination LOCK isis eere RO br AE o EAA 44 Router Delegation Buttons RTR 1 4 ccc cece cece cece eee e 45 Shift Reset BUTTONS 24 o orita eo FE Et ee ado UR AL o 45 Control Panel Browser Interface ee 45 Home Page sissantina etha ANTAA a TAAnae aes CAANIG Reha Aaa oer 45 Configuration Page socorro DU n 46 Network Page cece cece cece cece III hh eh hs 46 Lo AP m 46 Appendix A Specifications oooooooooooooooo 2 48 KUMO SDI Router Specificatio
2. Once connected and properly configured KUMO can then be controlled by a web browser or one or more KUMO CP control panels KUMO and KUMO CP are equipped with zeroconf Bonjour and support UPnP networking protocols but initially start up as DHCP active devices If you are operating on a DHCP server KUMO will take an assigned IP address and appear on the network Caution When attaching KUMO to a standard static IP LAN you must configure KUMO components with a new unique IP address You should first talk to your network administrator and find out how it should be connected TCP IP Static IP or DHCP Your IT department will be able to supply the information you need to install KUMO on a LAN KUMO uses TCP IP network communications and Ethernet connections a 10 100 1000 Ethernet port for crosspoint control status monitoring and software updates KUMO devices have an internal HTTP webserver that works with a standard web browser on a Mac or PC An Ethernet cable can also be used to connect an optional KUMO CP control panel directly to a KUMO router for operation without a computer KUMO devices are compatible with both CAT 5 straight through and cross over Ethernet cables they automatically detect whichever is used KUMOSs internal HTTP networking software supports three levels of network control e Closed KUMO network uses Default Auto Configure KUMO CP or Bonjour Mac or PC e Auto Configured LAN employs a Bonjour
3. 14 www aja com Computer Auto Discovery Mac Configuration with Safari Browser Using Bonjour NOTE NOTE Bookmark Icon x COLLECTIONS History Bookmarks Bar 302 Bookmarks Menu Address Book Bonjour Collection faa HH Home AJA eo Systems Apple Yahoo Google Maps YouTube Wikipedia News 302 v Popularv compatible IP network settings If these are the only KUMO devices on the network the KUMO CP should be able to control the KUMO router In addition if auto discovery is configured on a computer on that network that computer will be able to find and control the KUMO router via a web browser see below Stand alone KUMO operation described above works fine for some simple applications but you will probably want to be able to operate your KUMO system with a computer using a web browser UI and have the KUMO reside on an existing network to permit control from different locations AJA software updates selecting operating modes and choosing some other settings will also require a computer connection Computers can support network auto discovery which makes the network configuration process easy Two methods of connecting using this technique are described below The Mac OSX Safari browser has Bonjour built in which can be used to auto detect and connect to a KUMO router To do so 1 Start Safari browser on a Macintosh connected to the KUMO network ensure KUMO to be controlled is powered up and con
4. 50 60Hz power input and supplies 12 VDC to KUMO via connector PS 1 or PS2 Only one power supply is required and may be connected to either of the two power connectors An optional second power supply provides power redundancy to help protect against outages For additional protection connect the two supplies to different AC branch circuits so that KUMO will remain on even if there is a failure or open circuit breaker on one branch 7 www aja com RJ45 Ethernet Connector ID and Reset REF BNC connector Video Inputs and Outputs Normal mode Dual and Quad modes RS 422 DB9 Connector KUMO v3 1 The RJ45 Ethernet connector allows you to connect KUMO to an Ethernet 10 100 1000 Ethernet LAN using CAT5 cable as explained in the section that follows Multiple configurations are possible including standalone control a local LAN or a WAN The ID LED lights when you use the web interface to identify the KUMO unit you are controlling The Reset button pinhole below the LED allows a safeboot reset of the unit as explained in Chapter 3 Safeboot Reset on page 41 The REF BNC connector is the looping input for synchronizing the switching timing of KUMO to your house video signals Apply an analog NTSC PAL or Tri level sync signal to this input Also be sure to connect a terminator to the second connector or if you loop from that connector to other equipment be sure to terminate the connection at the other equipment When r
5. A14 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 Source17 Source18 Source19 Source20 Source21 Source22 Source23 Source24 Source25 Source26 Source27 Source28 Source29 Source30 Source31 Source32 Click Click Click Click Click Click Click Click Click Click Click Click Click Click Click Click DESTINATION 1 amp 2 3 als m5 m6 m7 m8 l 9 10 amp 11 amp 12 amp 13 amp 14 115 amp 16 amp Dest 1 Dest 2 Dest 3 Dest 4 Dest 5 Dest 6 Dest 7 Dest 8 Dest 9 Dest 10 Dest 11 Dest 12 Dest 13 Dest 14 Dest 15 Dest 16 Clic x Hide lick Click Click Click Click Click Click Click Click Click Click Click Click Click 17 amp Settings ar20 Aa 21 64 1122 64 23 4 24 64 1125 G amp G 26 amp 27 4 28 4 29 84 30 G31 64132 amp Dest 17 Dest 18 Dest 19 Dest 20 Dest 21 Dest 22 Dest 23 Dest 24 Dest 25 Dest 26 Dest 27 Dest 28 Dest 29 Dest 30 Dest 31 Dest 32 Click Click Click Click Click Click Click Click Click Click Click Click Click Click Click Click Mode Selection KUMO v3 1 Click on the Signal switching mode drop down list to select Normal Dual or Quad operating mode When Dual or Quad mode is selected the number of Source and Destination buttons will be reduced to match that configuration 36 www aja com Figure 32 Dual and Quad Mode Reduced Sources and Destinations 1 A29 als ali als ale AT ale als ali als AZ alu lis AIR 1 alz alas ala als als a7 ale Des Cen Cons Cond Haa Gon Dd DD Dd tl Geant Dd D Geant Daa 18 Dani Bea Bend Det Cond
6. KUMO Installation and Operation Guide Version 3 1 Published May 23 2014 KUMO 1604 KUMO 1616 KUMO CP KUMO 3232 PS2 Lh xs i e 101007000 LAN arra fe OOOO LAN AN LAN Fin i ET KUMO Med AALA me x IDENTIFY KUMO ted TTT co Q o o Because it matters VIDEO SYSTEMS Table of Contents alesi a coro ovs 9 92705092 Puis eU asa SEINE dE 203a 1 ue Ue P Pa FR ESI CNET TTD TUTTI 5 CODY sorna toronto Aia Ue NND PPP 5 COMTACEING Eeee sara bas Qi d ed eed EI qu du dE 5 Chapter 1 Introduction c eere eee hr D A 6 A5 onu rm 7 KUMO COBBSCHODS 2o cues E iden U REUS oA uet dts dou pedo idus bue pete 7 P S 1 amp P S 2 Power Connectors e 7 RJ45 Ethernet Connector e e ehh 8 Biak E OU m T 8 REF BNC CODDIBEIDE coe ds EEUU a n E sore 8 Video Inp ts arid OUTPUTS evitas ed Pads qu ree Pe Cea sca died 8 Normal ee repriser erter irera EAEE edites 8 Dual and Quad modes ee 8 RS 422 DB9 CONNECTO PN T PT 8 Older Model RS 422 Adapter 0 ccc cece eee eee e cece mm 9 KUMO Control and Monitoring ccc ccc cece cece IR 9 Network Configuration Overview ccc cece cece eee eee e eee hh 9 Direct Connsetlollueosese esae cose estarse E 9 LAN Connection Using a Hub or SWitch e e ee eee cece eee eeees 10
7. Gets software Version BK d Gets device name Queries ON S Gets all srcs by name ON IS Gets All srcs name amp index QN D Gets All dests names QN ID Gets All dests name amp indx ON L Gets levels hard coded as Kumo LevO e OD destname Gets protect On Off chop OFF sourceName level llevo e Od destname Gets protect On Off chop OFF sourceName level levO Control TD destname srcname Takes by name Tl destindx srcindxj Takes by index e PR destname levelmask Sets lock for given dest e UP destname levelmask Unsets lock for given dest 49 www aja com RS 422 Control Specifications e Baud Rate 38400 Parity None e Stop Bit 1 e Data Bits 8 Serial Port RS 422 slave pinout 9 pin available beginning with version 2 0 firmware Connector pinout is as follows GND TX RX GND No Connection GND TX RX GND Shell GND A m o A S Ethernet Control Specifications Ethernet Control Port TCP IP Port 12345 KUMO v3 1 50 www aja com Appendix B Safety amp Compliance Federal Communications Commission FCC Compliance Notices Class A Interference This equipment has been tested and found to comply with the limits for a Class A digital Statement device pursuant to Part 15 Subpart B of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a commercial installation This
8. Specifications KUMO SDI Router Specifications Formats Video Inputs Outputs Standards Cable Equalization BNC inputs 1694 coax Input Output Return Loss BNC Reference Input Control Environment Power Size Weight SDI Signal Switch Note KUMO v3 1 3 0 Gbps 1 5 Gbps 270 Mbps DVB ASI Auto Select SDI SMPTE 259 292 296 and 424 BNC 270 Mb 400 meters 1 5 Gb 200 meters 3 Gb 140 meters gt 15dB to 270Mb gt 10db 1 5Gb to 3Gb Analog input passive looping BNCs Format NTSC PAL Tri level sync e 10 100 1000 Ethernet RJ 45 internal Linux OS web server e RS 422 Serial DB9 female Operating Temperature O to 40 Degrees C Relative Humidity 0 to 90 non condensing 100 240 VAC 50 60Hz 9 17 VDC 12 VDC nominal optional redundant power supply 12 VDC nominal 9 18 VDC range optional redundant power KUMO 1604 7 5 Watts 0 8A at 12VDC KUMO 1616 20 Watts 1 8A at 12VDC KUMO 3232 26 4 Watts 2 2A at 12VDC Depth 1 RU 1 5 38 1 mm 2 RU 1 543 39 2 mm Height 1 RU 1 72 43 7 mm 2 RU 3 47 88 14 mm Width 1 RU and 2 RU 19 483 mm KUMO 1604 1 2 Ib 55 kg KUMO 1616 1 4 Ib 64 kg KUMO 3232 4 58 Ibs 2 1 kg KUMO routers switch SDI signals in a manner compliant with SMPTE RP168 2009 Because KUMO routers or any similar router switch the SDI stream without de serializing the switch point can cause a temporary anomaly in the SDI stream This can ca
9. es do fabricante Avviso Non ostruire le aperture di ventilazione Installare in conformit con le istruzioni del fornitore Warning Do not install near any heat sources such as radiators heat registers stoves or other apparatus including amplifiers that produce heat Avertissement N installez pas l appareil pr s d une source de chaleur telle que des radiateurs des bouches d air de chauffage des fourneaux ou d autres appareils amplificateurs compris qui produisent de la chaleur Warnung Nicht in der N he von W rmequellen wie Heizk rpern Heizregistern fen oder anderen W rme erzeugenden Ger ten einschlie lich Verst rkern aufstellen iAdvertencia No instale cerca de fuentes de calor tales como radiadores registros de calor estufas u otros aparatos incluidos amplificadores que generan calor Aviso N o instale perto de nenhuma fonte de calor tal como radiadores sa das de calor fog es ou outros aparelhos incluindo amplificadores que produzam calor Avviso Non installare vicino a fonti di calore come termosifoni diffusori di aria calda stufe o altri apparecchi amplificatori compresi che emettono calore KUMO v3 1 55 www aja com Warning A Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third prong are provided for
10. page 45 KUMO CP provides inputs for two power supplies one included redundant supply optional An RJ 45 connector provides 10 100 1000 Ethernet connection to the internal Linux OS web server 43 www aja com Button Key Caps Panel Function Buttons Panel Lock Destination Lock NOTE KUMO v3 1 Figure 41 KUMO CP Connectors and Indicator Power Supply Identify LED Ethernet Connectors www nja com T 100 1000 LAN KUMO CP Each control panel button has a removable lens cap that allows you to customize Source and Destination names AJA has provided a template for printing custom lens chips we suggest using 29 lb vellum for button designations The template is available on your software CD and at http www aja com support kumo lens_chip zip Each KUMO Control Panel provides e Panel Lock prevents Source or Destination changes from this panel Destination Lock prevents any Source change for a Destination Router Delegation Buttons RTR 1 RTR 4 enable immediate control of the KUMO assigned to the button Figure 42 KUMO CP Function Buttons When you press the Panel Lock button it lights red and all panel functions for this panel are disabled All other KUMO devices on the network will function normally Press the Destination Dest Lock button to prevent any changes to the KUMO destination you are currently controlling Dest button high tallied The lock can be removed from any other KUMO CP
11. 292M 424M e KUMO v3 0 firmware supports dual and quad mode routing allowing users to group together inputs and outputs for multiple cable applications like Dual Link Quad HD Quad split monitors etc e Automatic equalization and re clocking e Supports all ancillary data including embedded audio e Reference via BNC passive loop PAL NTSC color black or HD tri sync e 10 100 1000 Ethernet LAN e Embedded Linux OS with internal webserver for web browser control e HTTP Control Optional pushbutton remote control panel via Ethernet e TRU form factor for 16x16 2 RU for 32x32 e Redundant Power optional isolated power inputs KUMO Connections Redundant 12 VDC RJ45 Ethernet Power Supplies 10 100 1000 P 51 amp P S5 2 LAN Connector y TT y FN FN Lu 8 9 com 2 IDENTIFY A mem KUMO 10 100 1000 LAN RS 422 Serial Identify LED amp 3232 DB9 Female Reset Slot Connector below LED P S 1 amp P S 2 Power Connectors KUMO v3 1 Figure 1 KUMO Rear Panel Connections 3232 shown other models similar REF BNC In Ext Ref Video SDI Video Inputs 1 32 Looping top two rows o Q K T L PJ CHO o sh O O in c b h E 2 rl LE el A 7 P outputs yS i Ma d Ur CP d el WP el d d ouf o k L SDI Video Outputs 1 32 bottom two rows Power to the KUMO unit is supplied by a power supply brick that accepts a 110 220VAC
12. Avvertenza Non aprire lo chassis All interno non ci sono parti riparabili dall utente L apertura dello chassis invalidera la garanzia se non viene effettuata da un centro ufficiale o autorizzato AJA KUMO v3 1 61 www aja com Warning A Disconnect the external AC power supply line cord s from the mains power before moving the unit Avertissement Retirez le ou les cordons d alimentation en CA de la source d alimentation principale lorsque vous d placez l appareil Warnung Trennen Sie die Wechselstrom Versorgungskabel vom Netzstrom bevor Sie das Ger t verschieben iAdvertencia Cuando mueva la unidad desenchufe de la red el ctrica el los cable s de la fuente de alimentaci n CA tipo brick Advert ncia Remova os cabos CA de alimentac o brick da rede el trica ao mover a unidade Avvertenza Scollegare il cavo dell alimentatore quando si sposta l unit KUMO v3 1 62 www aja com Caution x When attaching KUMO to a standard Static IP LAN you must configure KUMO components with a new unique IP address You should first talk to your network administrator and find out how it should be connected TCP IP Static IP or DHCP Your IT department will be able to supply the information you need to install KUMO on a LAN Methods for assigning Static IP addressing are discussed in the KUMO Installation and Operation manual Attention Lorsque vous branchez l appareil KUMO un r seau LAN IP fixe standard vous devez configur
13. Cot Dex Dex Uieh Cich Cich CHk Ck Sie Cik Ch Cic Cikk Cika Cik Cikk _ Okk Ch Cl Clik In Dual and Quad modes adjacent BNCs are used for each routed signal Table 7 Dual and Quad Mode BNC Connectors and Signals Dual Mode Quad Mode ance al oncs und oncs sirat m p web mp s p expe se p mmm 510 s pmo mure fraja mme Button Settings Using the Configuration screen you can click on the name fields to assign custom Source and Destination names to the inputs and outputs of the router For any button click outside the naming field to access the Button Settings panel The Settings selection allows you to pick a color from the settings panel to color code the control panel button backgrounds The selected color is set for both the static state color and the High Tally rollover active state Figure 33 Button Settings Color Panel Button Settings x Access Hide El Lock E Apply Cancel KUMO v3 1 37 www aja com Lock Ifyou want to lock any of the Destinations from Source changes click on the Lock Unlock box for the desired Destination NOTE Thislock is a universal lock for all KUMO devices controlling the selected Destination It is tallied throughout the network and can be released from other KUMO control devices on the network Hide You can also hide selected Destinations from display on the local Home control panel by activating the Show Hide box Network Setup
14. Default Network Settings e rar 10 INTO a aros Roa 11 Chapter 2 Installation eee eer nr rr 12 ne EDDA prd deinde bibo be b 12 Whats In The BOK irc 12 KUMO Chassis Installation e IRI 13 Where to Place KUMO ccc cc cect ccc een e hs 13 Physical Requirements cc cece cece cece enhn 13 Power Requirements x e e e e e cece cc cece ehh hh hh rh nn 13 Physical Equipment Setup ccc ccc cece ee hn 14 Quick Start Configuration uice ud a ardua dor esses Rene hx Sr walter de d anaes aes 14 Default Auto Configure KUMO Router and CP ccc ccc eect eee tees 14 DHCP on an Existing Network e cece cece cece e eee e eee eeeeeeeeeeeeees 14 Computer Auto DiSCOVELY cee ccc cece cence teen een hh nnn 15 Mac Configuration with Safari Browser Using Bonjour 15 Windows 7 PC Configuration using UPnP se e ccc eee ee eee ees 16 KUMO Temporary Static IP AddresS oooooooococcccccrcooanncccca 16 Network Configuration Overview e cece e hn 18 RII e delal ee E TT T D UU TIT TT 19 LAN Connection Using a Hub or SWitch e e eee ee eee eee eeeeees 19 Sertupand Control Methods aree re SERE bed S PEN Ya etra n Re 20 Setup and Control from a Browser on Mac OSX eee ee eet een eee 21 Safari Browser Using BONjOUL ccc cece cc eee en 21 Safari Browser Type in KUMO Static IP Address 0c cece cece eens 21 Se
15. RTR 2 3 4 KUMO3232 559 M Unassigned v Unassigned Y Unassigned Unassigned KUMO1616 519 KUMO3232 559 Refresh 45 www aja com The assigned router name appears below each button You can change the selected currently controlled router on the panel by clicking the a button on the Home page The panel s router select button will tally appropriately Configuration Page Using the Configuration page you can e Adjust the Display Intensity slider select one of four button illumination levels e Reset Auto Configure resets the Auto Configure function to automatically set up one control panel to one router This function re boots the panel to trigger the configuration Upon reboot if any other router is found on the network it will not pair to the panel e Reset to Factory Defaults resets all user settings to factory defaults Figure 45 KUMO CP Browser Configuration Page HOME CONFIGURATION NETWORK FIRMWARE ALARMS IDENTIFY JSCP40 2 Y Display Intensity 2 Reset Auto Configure Reset To Factory Defaults Network Page The Network screen provides access to standard TCP IP setup fields and allows you to Click on the System Name field to change it The MAC address is a fixed machine address composed of manufacturer identification and product serial numbers Click the Update Network Settings button to enter your settings Figure 46 KUMO CP Network Setup Screen VIDEO SYSTEMS HOME CON
16. Y a E KUMO compact SDI routers are small and cost effective yet robust and reliable KUMO supports full broadcast specifications over SDI HD SDI and 3G SDI Additionally KUMO routers support SDI related protocols such as 270mb ASI and Canon 3G SDI RAW Kumo routers are re clocking non blocking and ready for any broadcast production or post production environment Running Embedded Linux KUMO routers support powerful HTTP control and monitoring KUMO contains an internal webserver that allows immediate installation configuration and operation without requiring additional software It offers a powerful user interface via any standard web browser KUMO SDI routers are available in three configurations e KUMO 1604 up to sixteen SDI inputs and four outputs e KUMO 1616 up to sixteen SDI inputs and sixteen outputs e KUMO 3232 up to thirty two SDI inputs and thirty two outputs KUMO also supports dual and quad port switching modes which simplify multi port SDI signals such as dual link and 4K quad link or switching 2 or 4 sources at once for any reason Because of their compact 1RU and 2 RU sizes KUMO SDI routers are ideal for space sensitive applications such as mobile sports trucks edit suites corporate video installations or live theatrical A V rigs 6 www aja com KUMO Features The KUMO routers offer the following features for ease of use in any environment e Support for SD SDI HD SDI 3G SDI SMPTE 259M
17. and not just a printer utility Juno 27 2013 4 r sa Support E mail 3 Click on Add to Firefox follow the installation instructions and restart Firefox 4 The DNSSD icon should now appear on the Firefox Navigation toolbar Figure 18 DNSSD Icon NOTE Ifthe DNSSD icon is NOT displayed in the Firefox Navigation toolbar do the following A If the menu bar is not displayed click on the Firefox name at the top left of the screen then click on Options and activate the Menu Bar B Click on View Toolsbars Customize C Locate the DNSSD icon and drag it to your preferred Firefox toolbar location KUMO v3 1 25 www aja com Accessing KUMO 1 Clickon the DNSSD icon to open a drop down list of all the KUMO devices accessible Devices in Firefox on the network Figure 19 Firefox DNSSD list of KUMO Devices Mozilla Firefox Start Page Search or enter address Mod ri Tanner e Websites s AJA KUMO1616 519 e AJA KUMO3232 559 AJA KUMOCP40 749 Moi HH MA FALLAR o FPA L Pd ea aT Browser Configuration Options Diagnostic Information 2 Click on a KUMO device s name to open its webpage 3 Once connected to KUMO s web interface reconfigure KUMO s network parameters as desired Windows 7 Browser KUMO offers a factory default static IP address The default static IP address is temporary Type in KUMO Static andis intended only to allow an initial connection Once you ve connected using the IP A
18. equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help FCC Caution This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Canadian ICES Statement Canadian Department of Communications Radio Interference Regulations This digital apparatus does not exceed the Class A limits for radio noise emissions from a d
19. operation after this procedure A Use Control Panel to access your Local Area Network properties In Windows XP the path is e Start gt Control Panel gt Network and Internet Connections gt Network Connections B Then under Network Connections locate and click on the Local Area Connection for the PC s Ethernet port Figure 23 Windows Network Configuration Screen K Network Connectio E coi Cr ag ype ey U Olt uelit ravi S TICES i wi o Network Tasks Ba gt Q s Create a new connection pe Set up a home or small office network l Change Windows Firewall settings Lal Disable this network device ET Repair this connection mi Rename this connection view status of this connection Change settings of this connection Other Places L Control Panel amp J My Network Places E Mv Documents x My Computer Details Local Area Connection LAN or High Speed Internet Limited or no connectivity Realtek RTL5139 510 Family Fast Ethernet MIC KUMO v3 1 n 55 General Support E AAPP sabe C In the resulting General dialog screen select the Properties button h MES Folders L earkhlink Disconnecked CRL PCI Data Fax Soft Modem with LAN or High 5peed Internet 42 Local Area Connection Status Local Area Connection Properties El E General Authentication amp dvanced Connection Conng amp b using Duration Speed This connection uses the following th
20. or UPnP enabled computer browser to automatically connect devices and allows KUMO web browser User Interface UI e Standard TCP IP network employs DHCP or Static IP addressing and allows the KUMO web based UI and an unlimited number of KUMO routers and up to 16 KUMO CP control panels The following web browsers have been tested and approved for use with KUMO Bonjour capability is recommended Firefox latest version on all platforms e Safari latest version MAC and Windows IE 7 8 latest versions Windows e Chrome latest version on all platforms Bonjour is supported but DNSSD as a discovery tool is not available for Chrome Bonjour software is built into Apple Macs with OS X from version 10 2 onward and can be installed onto Windows PC computers Bonjour for Windows adds zero configuration capabilities to Internet Explorer and with the DNSSD plug in to Firefox Once connected you can use a web browser to e Configure any TCP IP settings 18 www aja com Select and name KUMO routers and control panels e Assign a KUMO panel to be able to control specific KUMO routers e Name sources and destinations e Make Source to Destination assignments signal routing e Change router operating mode SDI 2K 4K Set a variety of operational and monitoring options Direct Connection In a direct connection you simply connect the control computer Mac PC or a KUMO CP control panel to a KUMO router using an Ethernet cable ca
21. or browser interface on the network The DEST and DEST LOCK buttons turn red on all panels that are assigned to the KUMO you are controlling You can select other destinations and apply the Dest Lock function to each All locks will tally red To remove the lock select the destination and press Dest Lock again Locked destinations are reported on the KUMO router s browser Home page with a lock icon 44 www aja com Router Delegation Buttons RTR 1 4 Shift Reset Buttons Control Panel Browser Interface KUMO v3 1 Home Page Figure 43 KUMO Router Home Page Destination Buttons DESTINATION O CSSt CS S S 112 3 4 A lt Lockicon Dest 2 Dest 3 Dest 4 de t Use the Router delegate buttons to connect to the specific router to be controlled If you are using the KUMO web browser interface you can assign the delegate buttons to any of up to four routers in your system To assign router control panel delegation you will access the Home page for your KUMO CP The SHIFT SRC and SHIFT DEST buttons serve multiple functions They allow you to select shifted sources and destinations 17 32 and they also perform the same reset functions as the reset slot Resets should be done only by qualified network personnel Shift Hold down SHIFT SRC and press a source button to select a shifted source or hold down SHIFT DEST and press a destination button to select a shifted destination When a shift button is n
22. router enabling quick physical location of the router in a populated rack of equipment Click again to turn it off Figure 38 Identify LEDs Identify LE front panel Identify LED rear panel K IDENTIFY KUMO 1604 KUMO v3 1 42 www aja com Chapter 4 KUMO Remote Control Panel Connectors and KUMO v3 1 Indicator The KUMO CP Control Panel is a destination oriented panel allowing selection of up to 32 sources and destinations on each of up to four KUMO routers The control panel will connect to a single KUMO router automatically without computer browser interface For connection to up to four routers at a time use the KUMO browser interface to assign the router select buttons to any four KUMO routers on your network Figure 39 Direct Connect KUMO Control KUMO CP Gi Router hd Up to 16 KUMOCPs Multiple Control Panels El El 1E EFETITITTI 89998999 a Cat 5 Ethernet Cabling Ethernet Switch m ar kd els ll aa LA E TA TA 59 a l f L K E B a A EI Up to 4 KUMOs per Control Panel Web Browser User Interface In this multi router network configuration with Ethernet connection between control panels and routers the Router Delegation Buttons shown below are assigned to up to four active routers using the control panel web interface for details see Home Page on
23. than home area Equipment for Office Use Sellers or users need to take note of this Taiwan Compliance Statement Ee EPA gt EAE PS HIS RARA FR HEBE BHBPEEMREOSRBORESSBISU This is a Class A product based on the standard of the Bureau of Standards Metrology and Inspection BSMI CNS 13438 Class A Japanese Compliance Statement 1 Class A ITE COREIA 7 7 AA Tix EIE CT CORREA EAI COR E amp 5 amp tec d CCD Us d c Oca RIDUEUIS TRAE RES SLIBREN amp cCchb Uss VCCIl A This is a Class A product based on the standard of the VCCI Council VCCI V 3 2008 04 If this equipment is used in a domestic environment radio interference may occur in which case the user may be required to take corrective actions Translated Warning and Caution Messages The following caution statements warning conventions and warning messages apply to this product and manual Warning Symbol Caution Symbol KUMO v3 1 53 www aja com Before Operating Please Read These Instructions Warning Read and follow all warning notices and instructions marked on the product or included in the documentation Avertissement Lisez et conformez vous tous les avis et instructions d avertissement indiqu s sur le produit ou dans la documentation Warnung Lesen und befolgen Sie die Warnhinweise und Anweisungen die auf dem Produkt angebracht oder in der Dokumentation enthalten sind iAdvertencia Lea y siga todas las instrucciones y advertenci
24. 9 Source10 Source11 Source12 Source13 Source14 Source15 4 5 6 d 8 Source4 Source 5 Source b Source 7 Source 8 3 Source 3 32 Source32 25 26 27 28 29 30 31 Source25 Source26 Source27 Source28 Source29 Source30 Source31 20 21 22 23 24 Source20 Source21 Source22 Source23 Source24 19 Source19 15 Dest 15 13 Dest 13 14 Dest 14 11 Dest 11 12 Dest 12 9 Dest 9 10 Dest 10 d Dest 7 8 Dest 8 9 Dest 5 6 Dest 6 4 Dest 4 3 Dest 3 29 30 31 Dest 29 Dest 30 Dest 31 27 Dest 27 28 Dest 28 26 Dest 26 24 Dest 24 25 Dest 25 21 Dest 21 22 23 Dest22 Dest 23 19 Dest 19 20 Dest 20 In Configuration you can hide Destination buttons that are not wanted for control from your location see Hide on page 38 From the Configuration screen you can select the operating mode Normal Dual Quad change the Source and Destination names and the colors of the buttons and Lock and Hide Destination buttons Figure 31 KUMO Web Interface I O Configuration Screen VIDEO SYSTEMS Reference 1080i 29 97 GURATION NETWORK FIRMWARE ALARMS IDENTIFY Click button to edit right click for more options 1 2 d 4 5 6 7 8 9 10 11 12 13 14 15 16 Source 1 Source2 Source 3 Source 4 Source 3 Source6 Source Source8 Source 9 Source10 Source11 Source12 Source13 Source14 Source15 Source16 Click Click Click Click Click Click Click Click Click Click Click Click Click Click Click Click
25. A Operar este equipamento em uma rea residencial provavelmente causar interfer ncia prejudicial neste caso espera se que os usu rios tomem as medidas necess rias para corrigir a interfer ncia por sua pr pria conta Attenzione Questo dispositivo un prodotto di Classe A Il funzionamento di questo apparecchio in aree residenziali potrebbe causare interferenze dannose nel cui caso agli utenti verr richiesto di adottare tutte le misure necessarie per porre rimedio alle interferenze a proprie spese Caution To meet safety regulations for leakage current when using redundant power supplies connect the KUMO dual power supplies to separate branch circuits Attention Pour satisfaire aux r glementations sur la s curit concernant le courant de fuite pendant l utilisation d appareils fournisseurs d alimentation redondants branchez les deux appareils fournisseurs d alimentation KUMO des circuits de d rivation distincts Achtung Um die Einhaltung aller Sicherheitsbestimmungen bzgl Ableitstrom beim Einsatz von redundanten Netzteilen sicherzustellen schlie en Sie die zwei KUMO Netzteile bitte an separate Abzweigleitungen an iPrecauci n Para cumplir con las regulaciones de seguridad con el prop sito de evitar p rdidas de corriente cuando se utiliza fuentes de alimentaci n m ltiples conecte las fuentes de alimentaci n dual KUMO a circuitos independientes Aten o Para atender as regulamenta es de seguran a re
26. Ao conectar o KUMO a uma LAN padr o de IP est tico preciso configurar os componentes do KUMO com um novo endereco IP exclusivo Voc deve primeiro conversar com seu administrador de rede e descobrir como ele dever ser conectado IP est tico TCP IP ou DHCP O seu departamento de TI estar dispon vel para fornecer as informa es necess rias para instalar o KUMO em uma LAN M todos para atribuir enderecos IP est tico s o abordados no manual de Instalac o e Operac o do KUMO Attenzione Quando si collega KUMO a un IP LAN statico standard occorre configurare i componenti KUMO con un nuovo indirizzo IP univoco Per prima cosa occorre parlare con l amministratore di rete e scoprire come effettuare la connessione IP statico TCP IP o DHCP Il reparto IT potr fornire le informazioni necessarie per installare KUMO su una LAN metodi di assegnazione dell indirizzo IP statico sono illustrati nel manuale KUMO Installazione e funzionamento KUMO v3 1 63 www aja com Index KUMO v3 1 A Apple Bonjour Print Services 23 Auto Configure 14 default direct connection 14 Auto Configured LAN 78 auto discovery 15 BNC connector Dual mode 8 37 Normal mode 8 Quad mode 8 37 reference 8 Bonjour 78 Win 7 installation 23 button colors 37 Button Key Caps 44 Button Settings 37 C cable routing 73 CAT 5 cross over 14 18 35 CAT 5 straight through 14 18 35 closed KUMO network 78 color code buttons 37 configuration quick star
27. ENAR ME 7 id Click the lock to prevent further changes Assist me Revert Apply N a Lu s F B Input the address information shown below e IP Address 192 168 101 X do not use 1 in the last octet e Subnet Mask 255 255 255 0 C Click Apply 3 Ensure the KUMO device to be controlled is connected to the Mac via Ethernet directly or via LAN 4 Start Safari and enter 192 168 101 1 as the web address This is the KUMO temporary static IP address 5 Once you ve connected using the static IP you can then enter a desired network configuration using the KUMO device s Network tab 6 Restore your computer to its normal network settings using this procedure and the IP addresses you recorded earlier Setup and Control from a Browser on Windows 7 The easiest methods of setting up a controlling a KUMO device from a PC running Windows 7 are e Setup and Control from a Browser on Windows 7 using UPnP Setup and Control from a Firefox Browser on Windows 7 using Bonjour Setup and Control from a Browser on Windows 7 using a Static IP Address KUMO v3 1 22 www aja com Windows 7 Using UPnP Universal Plug and Play Windows 7 Firefox Using Bonjour NOTE Install Apple Bonjour Print Services for Windows KUMO v3 1 This method was covered earlier in this chapter See Windows 7 PC Configuration using UPnP on page 16 Using Bonjour with Windows 7 and the Firefox browser requires the Apple Bonjou
28. FIGURATION NETWORK FIRMWARE ALARMS IDENTIFY Click IP Address Text to Edit System Name KUMOCP40 749 IP Address Type DHCP IP Address 10 9 250 22 Netmask 255 255 0 0 Default Gateway 10 9 0 2 MAC Address 00 0C 17 0E 80 F9 Update Network Settings Update Network Settings WARNING When you change the network configuration on your KUMO CP you can make it invisible to your web browser or difficult to find on your network It can take a minute or two for the KUMO CP to appear in the Bonjour browsing sidebar of your web browser so be patient before you decide it is gone If you cannot access the device you can simultaneously press and hold the two buttons labeled SHIFT SRC and SHIFT DEST on the unit for five seconds the KUMO CP will have a temporary IP address of 192 168 101 1 and a netmask of 255 255 255 0 allowing you to connect to it there and fix any network configuration errors Identify Button Click on the Identify button to find the physical location of currently controlled panel KUMO CP Identify Button HOME CONFIGURATION NETWORK FIRMWARE ALARMS IDENTIFY KUMO v3 1 46 www aja com The web browser button will alternate between blue and gray background color in Identify mode On the connected control panel the Source and Destination button rows will flash alternately Also the Identify LED on the back of the panel will flash Click a second time to resume normal operation KUMO v3 1 47 www aja com Appendix A
29. ION 2 3 5 6 7 8 Dest2 Dest3 Dest4 Dest5 Dest6 Dest7 Dest8 17 18 19 20 21 22 23 24 Dest17 Dest18 Dest19 Dest20 Dest21 Dest22 Dest23 Dest24 15 Dest 15 14 Dest 14 12 Dest 12 13 Dest 13 11 Dest 11 9 10 Dest 9 Dest 10 29 30 31 Dest29 Dest30 Dest 31 28 Dest 28 27 Dest 27 26 Dest 26 25 Dest 25 With multiple KUMO routers and KUMO CPs on the same network you can assign which routers are able to be controlled by a panel by configuring the four Router Select buttons on the panel Assign KUMO CP to Control KUMO Routers www aja com KUMO v3 1 33 KUMO v3 1 On the KUMO CP webpage go to the Home page click on the box below the RTR button and select the KUMO router from the drop down list Figure 28 KUMO CP Router Button Assignment HOME CONFIGURATION NETWORK FIRMWARE ALARMS IDENTIFY KUMOCP40 749 RTR 2 3 KUMO3232 559 M Unassigned Unassigned Unassigned KUMO1616 519 KUMO3232 559 Refresh 34 VIDEO SYSTEMS 4 Unassigned www aja com Chapter 3 KUMO Router Web Browser User Interface HOME CONFIGURATION NETWORK FIRMWARE ALARMS IDENTIFY Reference 10801 29 97 Pues KUMO3232 559 SOURCE 2 3 4 5 6 K 8 9 10 11 12 13 14 15 16 So Source 2 Source 3 Source 4 Source 5 Source Source Source8 Source 9 Source10 Source11 Source12 Source13 Source14 Source15 Source16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 Source17 Source18 Source19 Sou
30. OSX using a Static IP Address This method was covered earlier in this chapter See Mac Configuration with Safari Browser Using Bonjour on page 15 KUMO offers a factory default static IP address The default static IP address is temporary and is intended only to allow an initial connection Once you ve connected using the static IP you can then enter a desired network configuration using KUMO s Network tab The default static address is temporary and will be disabled the next time KUMO restarts Any changes in the Network configuration will be saved upon restart 1 Set the KUMO to its factory default IP address See KUMO Temporary Static IP Address on page 16 for this procedure 2 Configure your computer to talk on the 192 168 101 X subnet as shown below First record existing TCP IP settings so that you can return your computer to normal operation after this procedure A Go to your System Preferences Network and select Ethernet and Configure Manually 21 www aja com Figure 13 Mac Network Setup Screen System Preferences Network Network a gt Show All n Location enet local 7 17 06 9 23 AM tac 6 P Status Connected Ethernet is currently active and has the IP e AirPort address 0 0 0 0 e Firewire acd C4 Configure IPv4 Manually i IP Address 0 0 0 0 Subnet Mask Router DNS Server 10 0 1 1 Search Domains Advanced 7 ar n C
31. The Network screen provides access to standard TCP IP setup fields and allows you to click on the System Name field to change it The MAC address is a fixed machine address composed of manufacturer identification and product serial numbers Click the Update Network Settings button to enter your settings Figure 34 KUMO Network Setup Screen VIDEO SYSTEMS HOME CONFIGURATION NETWORK FIRMWARE ALARMS IDENTIFY Reference No Input Click IP Address Text to Edit System Name AJA KUMO1604 505 WARNING When you change the network configuration on your KUMO you can make MANSIS Ope once M it invisible to your web browser or difficult to find on your network It can take a minute or IP Address 169 254 3 87 two for the KUMO to appear in the Bonjour browsing sidebar of your web browser so Netmask 255 255 0 0 be patient before you decide it is gone If you cannot access the device you can press Default Gateway 0 0 0 0 and hold the safeboot button on the unit and when the Identify LED lights the KUMO will MAC Address 00 0C 17 87 00 1B have a temporary IP address of 192 168 101 1 and a netmask of 255 255 255 0 allowing you to connect to it there and fix any network configuration errors Update Network Settings Update Network Settings Firmware Updating AJA is constantly upgrading it s product software so it is a good idea to check the AJA website often for updates and to assure optimum system performance Go to the AJA KUMO Update pa
32. a necessaria quando il dispositivo stato danneggiato in qualche modo ad esempio se il cavo di alimentazione o la spina sono danneggiati stato rovesciato del liquido stato rovesciato o qualche oggetto caduto nel dispositivo il dispositivo stato esposto a pioggia o umidit non funziona correttamente o caduto KUMO v3 1 59 www aja com Caution X This device is a Class A product Operation of this equipment in a residential area is likely to cause harmful interference in which case users will be required to take whatever measures may be necessary to correct the interference at their own expense Attention Le p riph rique est un produit de Classe A Le fonctionnement de cet quipement dans une zone r sidentielle risque de causer des interf rences nuisibles auquel cas l utilisateur devra y rem dier ses propres frais Achtung Dies ist ein Ger t der Klasse A Bei Einsatz des Ger ts in Wohngebieten kann es St rungen des Radio und Fernsehempfangs verursachen In diesem Fall muss der Benutzer alle notwendigen Ma nahmen ergreifen die m glicherweise n tig sind um die St rungen auf eigene Rechnung zu beheben Precauci n Este es un producto clase A El uso de este equipo en reas residenciales puede causar interferencias nocivas en cuyo caso se requerir que los usuarios tomen cualquier medida necesaria para corregir la interferencia por cuenta propia Cuidado Este dispositivo um produto Classe
33. afety CB IEC 60065 2001 A1 2005 NRTL UL 60065 2003 R11 06 CSA C22 2 NO 60065 2003 A1 06 GS EN 60065 2002 A1 Additional licenses issued for specific countries available on request Emissions EN 55103 1 1996 EN61000 3 2 2006 EN61000 3 3 1995 A1 2001 A2 2005 Immunity EN 55103 2 1996 EN61000 4 2 1995 A1 1999 A2 2001 EN61000 4 3 2006 EN61000 4 4 2004 EN 61000 4 5 2005 EN 61000 4 6 2007 EN61000 4 1 1 2004 The product is also licensed for additional country specific standards as required for the International Marketplace Caution This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take appropriate measures Achtung Dieses ist ein Gerat der Funkst rgrenzwertklasse A In Wohnbereichen k nnen bei Betrieb dieses Ger tes Rundfunkst rungen auftreten in welchen Fallen der Benutzer f r entsprechende Gegenma nahmen verantwortlich ist Attention Ceci est un produit de Classe A Dans un environnement domestique ce produit risque de cr er des interf rences radio lectriques il appartiendra alors l utilisateur de prendre les mesures sp cifiques appropri es KUMO v3 1 52 www aja com Korea KCC Compliance Statement E ATLAR DARIA NA EE ABRE 534714 2 Fo aay bebe 1499 AAAA A gs AL As an electromagnetic wave equipment for office use Class A Broadcasting Communication this equipment is intended to use in other
34. as marcadas en el producto o incluidas en la documentaci n Aviso Leia e siga todos os avisos e instruc es assinalados no produto ou inclu dos na documentac o Avviso Leggere e seguire tutti gli avvisi e le istruzioni presenti sul prodotto o inclusi nella documentazione Warning Do not use this device near water and clean only with a dry cloth Avertissement N utilisez pas cet appareil pr s de l eau et nettoyez le seulement avec un tissu sec Warnung Das Gerat nicht in der Nahe von Wasser verwenden und nur mit einem trockenen Tuch s ubern iAdvertencia No utilice este dispositivo cerca del agua y l mpielo solamente con un pano seco Aviso N o utilize este dispositivo perto da gua e limpe o somente com um pano Seco Avviso Non utilizzare questo dispositivo vicino all acqua e pulirlo soltanto con un panno asciutto KUMO v3 1 54 www aja com Warning A Do not block any ventilation openings Install in accordance with the manufacturer s instructions Avertissement Ne bloquez aucune ouverture de ventilation Suivez les instructions du fabricant lors de l installation Warnung Die L ftungs ffnungen d rfen nicht blockiert werden Nur gem den Anweisungen des Herstellers installieren iAdvertencia No bloquee ninguna de las aberturas de la ventilaci n Instale de acuerdo con las instrucciones del fabricante Aviso N o obstrua nenhuma das aberturas de ventilac o Instale de acordo com as instru
35. change the network configuration on your KUMO you can make it invisible to your web browser or difficult to find on your network It can take a minute or two for the KUMO to appear in the Bonjour browsing sidebar of your web browser so be patient before you decide it is gone If you cannot access the device you can press and hold the safeboot button on the unit and when the Identify LED lights the KUMO will have a temporary IP address of 192 168 101 1 and a netmask of 255 255 255 0 allowing you to connect to it there and fix any network configuration errors Select KUMO to Control from Webpage With multiple KUMO routers on the same network you can quickly select which router to control from the webpage From the Home screen use the pulldown menu in the upper left to see all of the KUMO routers present on the local LAN and select the one you want to control or monitor Figure 27 KUMO Router Selection VIDEO SYSTEMS HOME CONFIGURATION NETWORK FIRMWARE ALARMS IDENTIFY Reference 1080i 29 97 KUMO3232 559 7 KUMO1616 519 local KUMO3232 559 local 5 6 7 8 KUMOCP40 749 local 1 Source5 Source b Source7 Source 8 Refresh 16 Source16 12 13 14 15 Source12 Source13 Source14 Source15 9 10 11 Source 9 Source10 Source11 32 Source32 28 29 30 31 Source28 Source29 Source30 Source31 25 26 27 Source25 Source26 Source27 21 22 23 24 Source17 Source18 Source19 Source20 Source21 Source22 Source23 Source24 DESTINAT
36. ddress static IP you can then enter a desired network configuration using KUMO s Network tab NOTE The default static address is temporary and will be disabled the next time KUMO restarts Any changes in the Network configuration will be saved upon restart 1 Set the KUMO to its factory default IP address See KUMO Temporary Static IP Address on page 16 for this procedure 2 Configure your computer to 192 168 101 X as shown below this example is for a PC connected directly to KUMO IMPORTANT First record existing TCP IP settings so that you can return your computer to normal operation after this procedure A Use Control Panel to access your Local Area Network properties In Windows 7 the path is Control Panel gt Network and Internet gt Network and Sharing Center B Then under Connections click on the Local Area Connection for the PC s Ethernet port KUMO v3 1 26 www aja com Figure 20 Windows Network Configuration Screens Le Jr EE K Control Panel Metwork and Internet K Network and Sharing Center EN Search Control Panel pl Control Panel Home e View your basic network information and set up connections Change adapter settings A T X See full map Change advanced sharing settings THADSVISTAG4DEM Unidentified network Internet This computer See also View your active networks Connect or disconnect Bonjour HomeGroup T Unidentified network Access type in Public network Connec
37. del punto in cui esce dal dispositivo KUMO v3 1 57 www aja com Warning A Unplug this device during lightning storms or when unused for long periods of time Avertissement D branchez cet appareil pendant les orages avec clairsou s il est inutilis pendant de longues p riodes Warnung Das Ger t ist bei Gewittersturmen oder wenn es ber lange Zeitr ume ungenutzt bleibt vom Netz zu trennen iAdvertencia Desenchufe este dispositivo durante tormentas el ctricas o cuando no se lo utilice por largos periodos del tiempo Aviso Desconecte este dispositivo da tomada durante trovoadas ou quando nao utilizado durante longos per odos de tempo Avviso Utilizzare soltanto i collegamenti e gli accessori specificati e o venduti dal produttore quali il treppiedi e l esoscheletro KUMO v3 1 58 www aja com Warning A Refer all servicing to qualified service personnel Servicing is required when the device has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the device the device has been exposed to rain or moisture does not operate normally or has been dropped Avertissement R f rez vous au personnel de service qualifi pour tout entretien l entretien est exig quand l appareil a t endommag de quelque mani re que ce soit par exemple lorsque le cordon d alimentation ou la prise sont endommag s que du liquide a t vers ou des objet
38. dure is presented in step by step form later on these pages Mac OSX e Setup and Control from a Safari Browser on Mac OSX using Bonjour e Setup and Control from a Browser on Mac OSX using a Static IP Address Windows 7 e Setup and Control from a Browser on Windows 7 using UPnP Setup and Control from a Firefox Browser on Windows 7 using Bonjour Setup and Control from a Browser on Windows 7 using a Static IP Address Windows XP e Setup and Control from a Browser on Windows XP using UPnP Setup and Control from a Firefox Browser on Windows XP using Bonjour Setup and Control from a Browser on Windows XP using a Static IP Address All of the above methods are explained on the following pages Select the method that works the best for you and your environment 20 www aja com IMPORTANT When using KUMO in a DHCP or Static IP addressed network it is best to select and maintain a consistent network scheme If you use a mix of DHCP and Static IP addresses inconsistent performance can result The most stable operation is achieved when all IP addressing is either DHCP or Static Setup and Control from a Browser on Mac OSX Safari Browser Using Bonjour Safari Browser Type in KUMO Static IP Address KUMO v3 1 NOTE IMPORTANT The two easiest methods to set up and control a KUMO router system from a Mac are e Setup and Control from a Safari Browser on Mac OSX using Bonjour e Setup and Control from a Browser on Mac
39. e optional KUMO CP Control Panel Appendix A Specifications lists technical specifications for the product Appendix B Safety and Compliance information Index KUMO v3 1 11 www aja com Chapter 2 Installation Introduction KUMO SDI routers are easy to set up and use All of the steps for KUMO installation and configuration are documented in this chapter summarized as follows 1 Install the chassis in an appropriate rack If you are mounting multiple KUMO units try to place them visually in the same area so if you communicate with them via a network attached computer you can use the KUMOS Identify feature to flash the corresponding LED of the unit you re communicating with Ensure you have an Ethernet cable routed to where the KUMO will be placed 2 Assemble the Ethernet network connections to a closed network or LAN using Cat 5 Ethernet cable and any required switches and hubs Connect the KUMO to power connecting the power cord to mains AC If necessary configure device network settings for operation in your facility Cable the system SDI video source and destination equipment and reference signals Ov DT ww Se If operating with or 4K signals select the appropriate KUMO operating mode Warning Do not defeat the safety purpose of the grounding type plug Caution To meet safety regulations for leakage current when using redundant power supplies connect the KUMO dual power supplies to separate branch circuit
40. e image by following these steps 1 Power down the KUMO 2 Pressand hold the reset button by inserting a paper clip or other device in the reset slot on the back of KUMO 3 Apply power to the router and after a moment release the reset A Safeboot Reset is also available for the KUMO CP see Shift Reset Buttons on page 45 Figure 36 KUMO Rear Panel and Reset Slot P S 1 TUS IDENTIFY A ant KUMO 100 1000 161 2 Reset Slot Kumo reports alarms on the router front panel by lighting an Alarm LED and in the web browser UI by illuminating the border of the Alarms tab see below Alarms include Power Supply displays error condition if a redundant power supply is off line e Reference displays error condition if no valid video reference signal is found Over Temperature displays error if KUMO exceeds normal operating temperature 41 www aja com Figure 37 KUMO Web Interface Alarms Screen HOME CONFIGURATION NETWORK FIRMWARE ALARMS IDENTIFY Reference No Input AJAKUMO 1604 505 Normal Over Power Supply X Reference Temperature Sync Error None h cy PS Error Fly down Menu If you do not want any of the above conditions to report an error right click Control Opt click to access the fly down menu shown above Select Suppress to deactivate the specific alarm Locating a Specific Click on the Identify button to flash the Identify LEDs on the front and back panels of the KUMO KUMO
41. e progress meter o de SoftwareDeve d Obsolete Note Current and past releases of KUMO y browser to KUMO Update Page Dems AllFiles Cop Te cons KUMO v3 1 39 www aja com 2 When you have selected a valid KUMO image file click Open and then OK the upload in the web browser The file you select will upload to the KUMO and be tested for validity Incomplete corrupted or non KUMO software files are rejected HOME CONFIGURATION NETWORK FIRMWARE ALARMS IDENTIFY Reference 1080i 29 97 KUMO3232 559 M Current Firmware Version 3 0 0 0 Overall Progress Uploading Firmware Image flash HOME CONFIGURATION NETWORK FIRMWARE ALARMS IDENTIFY Reference 1080i 29 97 KUMO3232 559 x Current Firmware Version 3 0 0 0 Uploaded Firmware Version 3 0 0 6 Would you like to commit the uploaded firmware to flash now Commit Uploaded Firmware Cancel 4 Click Commit Uploaded Firmware The firmware will be loaded to flash Wait for this to complete HOME CONFIGURATION NETWORK FIRMWARE ALARMS IDENTIFY Reference 10801 29 97 KUMO3232 559 Current Firmware Version 3 0 0 0 Loading Version 3 0 0 6 Overall Progress Writing Firmware to Flash 5 When done click the Restart button to reset your KUMO and refresh the web browser and KUMO UI HOME CONFIGURATION NETWORK FIRMWARE ALARMS IDENTIFY Reference 1080i 29 97 KUMO3232 559 i Current Firmware Version 3 0 0 6 Writing Fi
42. eference is present Kumo will switch in vertical interval with respect to the reference input If no reference is present the Kumo will switch at random times Depending on your KUMO model up to 32 SDI SMPTE 259 292 296 424 video inputs and outputs can be connected to the video input and output BNC connectors In Normal mode BNC inputs and outputs have a one to one relationship with the SDI signals being routed In Dual mode inputs and outputs use adjacent pairs of BNCs for each routed signal In Quad mode four adjacent BNCs are used for each routed signal Table 1 Dual and Quad Mode BNC Connectors and Signals Dual Mode Quad Mode BNC Signal BNC Signal mre 5 qmm mar e r pa pew s rsz je KUMO includes an RS 422 female DB9 connector for making serial connections to other equipment This control connection enables interoperability with other devices including those that use GVG Native Protocol 8 www aja com Older Model RS 422 Older KUMO routers serial numbers ending in RO needed an RS 422 adapter for proper Adapter serial control operation This adapter was shipped with those older model routers Be aware of this fact if your facility has a mixture of older and newer KUMO routers that use RS 422 control Figure 2 RS 422 Adapter NOTE Only KUMO routers with a serial number ending in RO require this adapter KUMO routers with serial numbers ending in R1 do NOT require the adapter KUMO Control and M
43. ems More information ie Client for Microsoft Networks i File and Printer Sharing For Microsoft Networks m U Packe nedule dl Internet Protocol TCPZIF Activity TE at Description Transmission Control Pratecal Intermet Protocol The default Packets 3 136 Wide area network protocol that provides communication across diverse interconnected networks C Show icon in notification area when connected Notify me when this connection has limited or na connectivity D Then on the Local Area Connection Properties dialog select the Internet Protocol item and click the Properties button below it 30 www aja com Figure 24 Windows TCP IP Properties Screen Internet Protocol TCP IP Properties EEE General You can get IP settings assigned automatically if your network supports this capability Otherwise you need to ask your network administrator for the appropriate IP settings Obtain an IP address automatically Use the following IP address IP address Subnet mask Default gateway Use the following DNS server addresses Preferred DNS server Alternate DNS server ak cancel E Finally click the Use the following IP address radio button and enter the IP Address and Subnet Mask below e IP Address 192 168 101 X do not use 1 in the last octet e Subnet Mask 255 255 255 0 F Click the OK button to store the changes NOTE The previous step is tem
44. er les composants KUMO avec une nouvelle adresse IP qui soit unique Vous devez d abord consulter votre administrateur r seau pour savoir comment connecter l appareil TCP IP IP fixe ou DHCP Votre service informatique pourra vous fournir les informations n cessaires pour installer KUMO sur un r seau LAN Les m thodes d attribution des adresses IP fixes sont trait es dans le manuel d installation et de fonctionnement de KUMO Achtung Beim Anschlie en von KUMO an ein standardmafiges statisches IP LAN m ssen Sie die KUMO Komponenten mit einer neuen einzigartigen IP Adresse konfigurieren Fragen Sie bei Ihrem Netzwerkadministrator nach wie der Anschluss erfolgen soll TCP IP statische IP oder DHCP Ihre IT Abteilung kann Ihnen zudem alle n tigen Informationen liefern die Sie zur Installation von KUMO auf einem LAN ben tigen Die Methoden zur Zuweisung von statischen IP Adressen werden im KUMO Installations und Benutzerhandbuch besprochen iPrecauci n Cuando conecte KUMO a una LAN de IP est tica est ndar deber configurar los componentes KUMO con una direcci n de IP nueva y nica Primero deber contactarse con su administrador de red y averiguar el m todo de conexi n IP est tica TCP IP o DHCP Su departamento de TI podr suministrarle la informaci n que necesita para instalar KUMO en una LAN Los m todos para asignar direcciones IP est ticas se presentan en el Manual de instalaci n y funcionamiento de KUMO Atenc o
45. etwork and Internet hd 4 Search Control Panel D Control Panel Hom Eo Elk Network and Sharing Center al EE TA View network status and tasks Connect to a Add a wireless device to the network Network and Internet Click This Hardware and Sound ad HomeGroup Choose homegroup and sharing options Programs User Accounts and Family gt Internet Options Safety X Change your homepage Manage browser add ons Delete browsing history and cookies I na Il Adobe Version Cue CS4 32 bit Personalization 4 Lookatthe resulting device list under Other Devices double click a KUMO s name to launch your Window 7 PC s default browser Figure 9 Windows Network Screen Search Network Organize Network and Sharing Center Add a printer Add a wireless device WE Favorites Name Category Workgroup Network location Recently Changed a Computer 2 d Public R THADSVISTAGADEM Computer WORKGROUP Network isi E TOMMACGO Computer WORKGROUP Inidentified network A Downloads kn Recent Places E Media Devices 1 ff THADSVISTA amp 4DEM demo Media Devices poss wo Libraries 4 Other Devices 1 U t n alli AJAKUMO1616 555 ces Priceniniied network usc fe Pictures Vid M ves Double click the KUMO name to launch your default web browser E NIME 5 The browser will display the KUMO web user interface which you can use to control and configure that KUMO device Other methods of KUMO network connection and c
46. ge by clicking the link at the bottom of the Firmware screen Or enter this URL in your web browser http www aja com en products kumo support Current firmware version number is reported here under the pull down menu KUMO v3 1 38 www aja com Figure 35 KUMO Web Interface Firmware Upload Screen HOME CONFIGURATION NETWORK FIRMWARE ALARMS IDENTIFY Reference 1080i 29 97 DAA KUMO3232 559 a Current Firmware Version 0 0 0 0 Upload New Firmware Browse WARNING You are uploading new firmware to the KUMO After the new firmware is uploaded it will be verified and the version number of the firmware will be displayed You will then be asked if the firmware should be commited to internal flash memory After the firmware has been committed to flash you will be asked to confirm a reboot of the KUMO Note Your settings and configuration will remain as they are now Upon confirming a reboot you will be redirected to the front page of the web Ul and when the new software is up and running this web UI will start working again The progress meter on this web page should keep you informed of the progress Note Current and past releases of KUMO software are available on the World Wide Web from AJA s website To get the software point your browser to KUMO Update Page Serial Number 400559 Unpack the Software Download the latest version of KUMO firmware and use the Firmware screen to upload it to your KUMO router KUMO soft
47. igital apparatus as set out in the Radio Interference Regulations of the Canadian Department of Communications This Class A digital apparatus complies with Canadian ICES 003 R glement sur le brouillage radio lectrique du minist re des Communications Cet appareil num rique respecte les limites de bruits radio lectriques visant les appareils num riques de classe A prescrites dans le R glement sur le brouillage radio lectrique du minist re des Communications du Canada Cet appareil num rique de la Classe A est conforme la norme NMB 003 du Canada KUMO v3 1 51 www aja com European Union and European Free Trade Association EFTA Regulatory Compliance This equipment may be operated in the countries that comprise the member countries of the European Union and the European Free Trade Association These countries listed in the following paragraph are referred to as The European Community throughout this document AUSTRIA BELGIUM BULGARIA CYPRUS CZECH REPUBLIC DENMARK ESTONIA FINLAND FRANCE GERMANY GREECE HUNGARY IRELAND ITALY LATVIA LITHUANIA LUXEMBOURG MALTA NETHERLANDS POLAND PORTUGAL ROMANIA SLOVAKIA SLOVENIA SPAIN SWEDEN UNITED KINGDOM ICELAND LICHTENSTEIN NORWAY SWITZERLAND Declaration of Marking by this symbol indicates compliance with the Essential Requirements of the EMC Conformity Directive of the European Union 2004 108 EC cE This equipment meets the following conformance standards S
48. imply going to My Network Places and double clicking on the KUMO as follows 1 Ensure KUMO to be controlled is powered up and connected via Ethernet directly or via LAN to the Windows XP PC Go to Start My Network Places Locate the Icon for the KUMO being controlled and double click it Figure 21 Windows My Network Places Screen E My Metwork Places File Edit Back View Favorites Tools Help d P Search Folders FEE Local Network 55 Network Tasks Double Click the KUMO Icon HUE A KumoEngl1604 21 The Internet E My Web Sites on MSN 4 Double clicking a KUMO s icon launches your Window XP PC s default browser The browser will display the KUMO web interface Use it to control KUMO ad Add a network place a View network connections Set up a home or small office network 3j 3 ea Setup a wireless network For a home or small office fy View Workgroup computers m Hide icons For networked UPnP devices If you don t see a KUMO icon under Local Network on My Network Places ensure there is either a direct connection or LAN connection and the KUMO is powered up With those requirements satisfied if no Icon can be seen then likely the UPnP services are disabled 1 Goto Start gt Control Panel and then click Add or Remove Programs 28 www aja com 2 In the Add or Remove Programs dialog box click Add Remove Windows Components Figure 22 Window
49. ion CD 5 Goto Start gt My Network Places again and look for the KUMO icon as shown previously UPnP devices on your local network will be displayed there including KUMO Whenever a KUMO is connected a notifying icon will appear briefly in the System Tray When you see the icon go to My Network Places to find the KUMO icon and double click it to launch KUMO s web interface for control and setup Windows XP Firefox The Windows XP configuration required for using Bonjour with Firefox is the same as that Using Bonjour used for Windows 7 See Windows 7 Firefox Using Bonjour on page 23 Windows XP KUMO offers a factory default static IP address The default static IP address is temporary e i and is intended only to allow an initial connection Once you ve connected using the rowser type In KUMO Static IP static IP you can then enter a desired network configuration using KUMO s Network tab Address KUMO v3 1 29 www aja com NOTE The default static address is temporary and will be disabled the next time KUMO restarts Any changes in the Network configuration will be saved upon restart 1 Set the KUMO to its factory default IP address See KUMO Temporary Static IP Address on page 16 for this procedure Configure your computer to talk on the 192 168 101 X subnet as shown below this example is for a PC connected directly to KUMO IMPORTANT First record existing TCP IP settings so that you can return your computer to normal
50. l enchufe de la red el ctrica se utiliza como dispositivo de desconexi n debe seguir siendo f cilmente accesible y operable Aviso Dado que a ficha principal utilizada como a desconex o para o dispositivo esta deve manter se prontamente acess vel e funcional Avviso Poich il cavo di alimentazione viene usato come dispositivo di sconnessione deve rimane prontamente accessibile e operabile Warning Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the device Avertissement Prot gez le cordon d alimentation pour que l on ne marche pas dessus ou qu on le pince en particulier au niveau des prises m les des r ceptacles de convenance et l endroit ou il sort de l appareil Warnung Vermeiden Sie dass auf das Netzkabel getreten oder das Kabel geknickt wird insbesondere an den Steckern den Steckdosen und am Kabelausgang am Gerat iAdvertencia Proteja el cable de energ a para que no se le pise ni apriete en especial cerca del enchufe los recept culos de conveniencia y el punto del que salen del equipo Aviso Proteja o cabo de alimentac o de ser pisado ou de ser comprimido particularmente nas fichas em tomadas de parede de conveni ncia e no ponto de onde sai do dispositivo Avviso Proteggere il cavo di alimentazione in modo che nessuno ci cammini sopra e che non venga schiacciato soprattutto in corrispondenza delle spine e
51. l frontal aquecido em condic es de operac o normais e ativas Attenzione KUMO sfrutta lo chassis per migliorare il raffreddamento E normale per lo chassis 1616 data la concentrazione di cavi che il panello anteriore si riscaldi durante la normale attivit Warning Do not open the chassis There are no user serviceable parts inside Opening the chassis will void the warranty unless performed by an AJA service center or licensed facility Avertissement Ne pas ouvrir le ch ssis Aucun l ment l int rieur du ch ssis ne peut tre r par par l utilisateur La garantie sera annul e si le ch ssis est ouvert par toute autre personne qu un technicien d un centre de service ou d un tablissement agr AJA Warnung Offnen Sie das Geh use nicht Keine der Ger teteile k nnen vom Benutzer gewartet werden Durch das ffnen des Geh uses wird die Garantie hinf llig es sei denn solche Wartungsarbeiten werden in einem AJA Service Center oder einem lizenzierten Betrieb vorgenommen iAdvertencia No abra el chasis El interior no contiene piezas reparables por el usuario El abrir el chasis anular la garant a a menos que se lo haga en un centro de servicio AJA o en un local autorizado Advert ncia N o abra o chassi N o h internamente nenhuma peca que permita manutenc o pelo usu rio Abrir o chassi anula a garantia a menos que a abertura seja realizada por uma central de servicos da AJA ou por um local autorizado
52. lativas corrente de fuga ao usar fontes de alimentac o redundantes conecte as fontes de alimentac o duplas KUMO para separar os circuitos derivados Attenzione Per soddisfare i requisiti di sicurezza per la corrente di dispersione usando alimentatori ridondanti collegare i doppi alimentatori KUMO per separare i circuiti derivati KUMO v3 1 60 www aja com Caution x KUMO is designed to take advantage of its chassis to aid in cooling It is common and expected for the densely populated 1616 chassis to have a warm front panel in normal active operating conditions Attention KUMO est concu pour tirer parti de son chassis pour le refroidissement Il est normal et attendu que le panneau frontal du tr s compact ch ssis 1616 demeure chaud dans des conditions normales de fonctionnement Achtung Das Design von KUMO nutzt das Geh use zur K hlung Es ist normal und entspricht den Erwartungen dass die Vorderseite des dicht best ckten 1616 Geh uses bei normalen aktiven Betriebsbedingungen warm ist Precauci n KUMO est dise ado para aprovechar el chasis para asistir en el proceso de enfriamiento Es com n y est previsto que el chasis 1616 densamente surtido de componentes tenga el panel frontal caliente en condiciones normales y activas de funcionamiento Atenc o O KUMO foi projetado para aproveitar seu chassi para auxiliar no resfriamento normal e esperado que o chassi 1616 densamente preenchido apresente um paine
53. ll for Google Chrome Install for Mozilla Firefox Source code hosted on GitHub Extension Plugin Website For all inquiries please email KUMO v3 1 24 www aja com 2 Click on Install for Mozilla Firefox to go to the Firefox Add Ons webpage Figure 17 Firefox Add Ons Webpage Hhrefox 7 df DNSSD for Firefox Add ons for Firefox e Mozilla Foundation US https addons mozilla org en US firefox addon dnssd C Yahoo P amp A Most Visited Getting Started Customer LogIn Box Google IceWarp Web Mail _ Suggested Sites Web Slice Gallery EJ Bookmarks mozilla yp gt EXTENSIONS THEMES COLLECTIONS MORE Register or Login Other Applications Y m Extensions DNSSD for Firefox E DNSSD for Firefox 1 0 5 ARA C 3 user reviews a by andrewtj r 1 697 users iil DNSSD for Firefox adds support for discovering websites via DNS Service Discovery Apple Bonjour or compatible software is required Windows users please read the Add to collection prerequisites section in Developer s Comments below before installing Share this Add on Add to Firefox About this Add on ft Add on home page DNSSD for Firefox adds support for discovering websites via DNS Service Discovery Bonjour to Firefox Apple Bonjour must be installed for this add on to work Bonjour is bundled with OS X and available here for Windows ignore the E sini GU packaging it is the full product
54. mmends AJA p n 103147 00 Power Consumption KUMO 1604 9 Watts KUMO 1616 20 Watts KUMO 3232 26 4 Watts Caution KUMO is designed to take advantage of its chassis to aid in cooling It is common and expected for the densely populated chassis to have a warm front panel in normal active operating conditions Warning Do not open the chassis There are no user serviceable parts inside Opening the chassis will void the warranty unless performed by an AJA service center or licensed facility Remove the brick power supply AC line cord s from mains power when moving the unit 13 www aja com Physical Equipment Setup NOTE Before setting up the KUMO router s and KUMO CP panels ensure you ve got all equipment interconnected Connect power supplies 1 or 2 for redundancy to KUMO routers and control panels Connect source and destination SDI equipment this step can be deferred Connect network e Direct Connection connect a KUMO router to a KUMO CP if used or to a Mac or PC via an Ethernet Cable v LAN Connection connect a KUMO router and a KUMO CP if used to a hub or switch and connect a PC or Mac to the same LAN via a hub or switch KUMO devices are compatible with both CAT 5 straight through and cross over Ethernet cables they automatically detect whichever is used 4 Proceed to your desired network configuration method using one of the procedures presented later in the chapter Quick Start Configurati
55. nected via Ethernet directly or via LAN 2 Click on the Bookmark icon menu bar far left and select the Bonjour collection If the Bonjour collection is not visible go to Safari gt Preferences gt Bookmarks go to the Bookmarks Collections section and then check the Include Bonjour checkbox 3 Double click on the KUMO router or control panel in the Bookmarks pane The KUMO name will be similar to AJA KUMO1616 555 where 1616 is the model number and 555 is the unit s serial Figure 7 Safari Bonjour Bookmarks Bonjour t http www apple com startpage Bonjour KUMO CP KUMO Routers KUMO v3 1 All RSS Feeds US AJA KUMOCPTechw Bookmark About Bonjour GS AJA KUMOCPTechw e AJA KUMOEng1604 21 e AJA KUMOEng1604 27 4 Safari will display the KUMO web user interface which you can use to control and configure that KUMO device 15 www aja com Windows 7 PC If your Windows 7 PC supports UPnP protocols most do and UPnP service is enabled Configuration using refer to your Microsoft Windows documentation you can control KUMO routers by UPnP simply selecting one from a device list 1 Ensure KUMO to be controlled is powered up and connected via Ethernet directly or via LAN Use your Windows 7 Control Panel to go to Network and Internet Select View Network computers and devices Figure 8 Windows Network and Internet Screen 7 QC K Control Panel N
56. ngs for LAN WAN operation e Firmware update menu for KUMO software from AJA e Alarms log of service failures and allows alarms to be suppressed e Identify toggles activation of Identify LEDs for easy location of various system components Figure 29 KUMO Navigation Bar VIDEO SYSTEMS HOME CONFIGURATION NETWORK FIRMWARE ALARMS IDENTIFY Reference 10801 29 97 Click any of the first five tabs to jump to that screen To the right of the Identify button you will see the format of the Reference Video signal being used if present KUMO v3 1 35 www aja com KUMO Home Control Panel Operation HOME KUMO3232 559 SOURCE 17 2 Source 2 18 Source17 Source18 DESTINATION 17 Dest 17 2 Dest 2 18 Dest 18 NOTE Router Configuration HOME CONFI Signal switching mode Normal SOURCE CONFIGURATION From the Home screen you can use the pulldown menu in the upper left to see all of the KUMO routers present on the local LAN and select the one you want to control or monitor Immediately below the KUMO selection menu are the Source input buttons Below the Source input buttons are the Destination output buttons Click on any Destination and it will highlight and cause it s currently selected Source button to illuminate Figure 30 KUMO Web Browser Control Panel VIDEO SYSTEMS NETWORK FIRMWARE ALARMS IDENTIFY Reference 1080i 29 97 16 Source16 9 10 11 12 13 14 15 Source
57. ns sssssseeeee I Im 48 KUMO CP Specifications ccc III Ih 49 GVG Native Protocol Support cee cece eee een 49 RS 422 Control Specifications e Hn 50 Ethernet Control Specifications oooooooocoooorororoocrnnnnnrcr n 50 Appendix B Safety 8 Compliance 51 KUMO v3 1 3 www aja com Federal Communications Commission FCC Compliance Notices 51 Class A Interference Statement ccoo 51 ema Ui PTT A EA 5 Canadian ICES StateMent e e eee hh 51 European Union and European Free Trade Association EFTA Regulatory Compliance eee voa or e rias ia 52 Declaration Of COnfOEIilty cocer C ro S a CORO CR CEA UA d aa 52 Korea KCC Compliance Statement e e cece cece eee eeeeeeeeee 53 Taiwan Compliance Statement e 53 Japanese Compliance Statement e e eee 53 Translated Warning and Caution VMessa es e eee 53 Before Operating Please Read These Instructions e cc cece cece e eee eeeees 54 A A T KUMO v3 1 4 www aja com Notices Trademarks AJA KONA Ki Pro KUMO and XENA are registered trademarks of AJA Video Inc TruZoom TruScale Ki Pro Mini lo Express lo HD lo and Work Flow are trademarks of AJA Video Inc AirPort Apple the Apple logo AppleShare AppleTalk FireWire iPod iPod Touch Mac and Macintosh are registered trademarks of Ap
58. ntify LED will blink e Fora KUMO CP press and hold the two SHIFT buttons on the panel for 5 seconds When the KUMO CP default IP is set the Source and Destination buttons will flash alternately Figure 10 KUMO Reset Slot Location AAJA erre 8j8 com IDENTIFY REF KUMO 1616 i LU PU dY Reset Slot Reset Buttons IMPORTANT Be sure to record your computer s existing TCP IP settings before the next step so that you can return the computer to normal operation after this procedure 3 Configure your computer to 192 168 101 X Do not use 1 at the end of the address to avoid duplicate IP addresses NOTE Specific network reconfiguration procedures for Mac and PC are presented later in this chapter 4 Start a web browser and enter 192 168 101 1 as the web address This is the KUMO temporary static IP address 5 Once you ve connected using the static IP you can then enter a desired network configuration using the KUMO device s Network tab KUMO v3 1 17 www aja com Network Configuration Overview KUMO v3 1 NOTE A LAN is a shared network that includes other Ethernet devices all attached via a hub or digital switch LANs may be divided into zones separated by software or hardware routers Routers may also be used to connect the LAN to an outside wide area network WAN such as the internet Devices on a LAN have IP addresses which may be fixed and permanent or dynamically assigned by the network DHCP with DNS server
59. on Default Auto Configure KUMO Router and CP KUMO CP DHCP on an Existing Network KUMO v3 1 Some simple methods of quickly configuring your KUMO system for fast operation are presented here More detailed descriptions are presented later in this manual We strongly recommend that you read the full KUMO Manual to get the most out of your system If you purchased a KUMO CP along with your KUMO router the easiest way to get your system operating is to simply directly connect them with a single Ethernet cable and power up both units The KUMO CP will use an Auto Configure function to set itself up to operate with the KUMO router it is directly connected to The KUMO CP panel buttons will light and if SDI BNC connections have been made you will be able to route sources to destinations Figure 6 KUMO Router Direct Connection to KUMO CP KUMO Router Direct Cat 5 ethernet cable connection A KUMO CP that has had its network settings configured previously will not automatically find a directly connected KUMO router in this manner The Reset Auto Configure control on the KUMO CP s Configuration webpage can be used to restore this capability See Configuration Page on page 46 Another easy way to get your KUMO system operating is to connect the KUMO Router and KUMO CP to an existing network configured with a DHCP server When the units reset during power up they will see the DHCP server and automatically be given
60. onfiguration are described later in this chapter KUMO Tem porary KUMO devices also offer a factory default static IP address allowing a direct and fail safe Static IP Address way to connect via a computer connected to KUMO either directly or via a LAN connection The computer you use will need to be set to a static IP address that is KUMO v3 1 16 www aja com compatible with the KUMO temporary IP address Once connected the KUMO device s network settings can be reconfigured to work with your facility network The KUMO default static IP address is temporary and is intended only to allow an initial connection NOTE All KUMO routers and control panels have the same temporary default IP address so more than one device set to this default cannot reside on the same network simultaneously Work with only one device at a time Table 2 KUMO Device Temporary Static IP Address Values KUMO Router and KUMO CP 192 168 101 1 168 101 1 255 255 255 0 NOTE The default static address is temporary and will be disabled the next time KUMO restarts Any changes in the Network configuration will be saved upon restart To set KUMO to its default static IP address 1 Power up KUMO device and wait for it to boot normally 2 Resetthe KUMO device For a KUMO router insert a straightened paper clip or similar device into the reset slot on the rear hold for six seconds and then allow KUMO to restart When the KUMO router default IP is set the Ide
61. onitoring The KUMO router user interface provides powerful remote setup control and monitoring with e Zero configuration Bonjour Protocol and support for UPnP networking protocols e Remote web browser control interface via Ethernet Optional push button remote KUMO CP control panel for control of up to four KUMO routers e GVG Native Protocol built in to allow serial or LAN interconnection one RS 422 or up to ten Ethernet and interoperability with other equipment Specifically Kumo can be controlled by the SMS 7000 portion of the GVG Native Protocol For details refer to GVG Native Protocol Support on page 49 Also refer to Grass Valley documentation at http www grassvalley jp pdf RoutingProductsProtocolManual_2 pdf Network Configuration Overview KUMOSs internal HTTP networking software supports three levels of network control e Closed KUMO network uses Bonjour e Auto Configured LAN employs a Bonjour or UPnP enabled computer browser to automatically connect devices and allows KUMO web browser User Interface UI e Standard TCP IP network employs DHCP or Static IP addressing and allows the KUMO web based UI and an unlimited number of KUMO routers and up to 16 KUMO CP control panels Direct Connection In a direct connection the control computer Mac PC or a KUMO CP control panel connects to a KUMO router using an Ethernet cable cat 5 between the RJ45 connectors on both devices KUMO v3 1 9 www aja com Figu
62. ot held down pressing a source or destination button selects the unshifted source or destination 1 16 IP Reset Hold both buttons down for five seconds to perform an IP address reset to the temporary default IP address see KUMO Temporary Static IP Address on page 16 Reset to Factory Default Firmware Hold both buttons down at power up to perform a Safeboot Reset to the Factory Default firmware image The KUMO CP browser interface provides the same Navigation Bar tabs as the router This section discusses those functions unique to the control panel interface The Navigation Bar includes e Home assign router elect buttons to KUMO routers e Configuration adjust the control panel display intensity and if necessary Reset the panel to its original Auto Configure state or to original factory settings e Network and Firmware tabs same as KUMO router network settings see Network Setup on page 38 and Firmware Updating on page 38 e Alarms Power Supply and Over Temperature refer to KUMO Alarms on page 41 e Identify button to identify the physical location of a particular control panel Use the Home page to assign a router to each of the panel select buttons Each button has a pulldown menu that lists the active networked KUMOs for assignment and provides an Unassign and Refresh function Figure 44 KUMO CP Browser Interface Home Page HOME CONFIGURATION NETWORK FIRMWARE ALARMS IDENTIFY KUMOCP40 749 i
63. para su seguridad Si el enchufe suministrado no encaja en el tomacorriente consulte con un electricista para reemplazar el tomacorriente obsoleto Aviso N o anule a finalidade da seguranca da ficha polarizada ou do tipo ligac o terra Uma ficha polarizada tem duas l minas sendo uma mais larga do que a outra Uma ficha do tipo de ligac o terra tem duas l minas e um terceiro terminal de ligac o terra A l mina larga ou o terceiro terminal s o fornecidos para sua seguranca Se a ficha fornecida n o couber na sua tomada consulte um electricista para a substituic o da tomada obsoleta Avviso Non compromettere la sicurezza della spina polarizzata o con messa a terra Una spina polarizzata ha due spinotti di cui uno pi largo Una spina con messa a terra ha due spinotti e un terzo polo per la messa a terra Lo spinotto largo o il terzo polo sono forniti per motivi di sicurezza Se la spina fornita non si inserisce nella presa di corrente contattare un elettricista per la sostituzione della presa obsoleta KUMO v3 1 56 www aja com Warning A Since the Mains plug is used as the disconnection for the device it must remain readily accessible and operable Avertissement Puisque la prise principale est utilis e pour d brancher l appareil elle doit rester ais ment accessible et fonctionnelle Warnung Da der Netzstecker als Trennvorrichtung dient muss er stets zug nglich und funktionsf hig sein iAdvertencia Puesto que e
64. ple Computer Inc Final Cut Pro QuickTime and the QuickTime Logo are trademarks of Apple Computer Inc Avid Avid Media Composer and Avid DNxHD are trademarks of Avid Technology Inc All other trademarks are the property of their respective holders HDMI the HDMI logo and High Definition Multimedia Interface are trademarks or registered trademarks of HDMI Licensing LLC DVI is a registered trademark of DDWG All other trademarks are the property of their respective holders Copyright Copyright O 2014 AJA Video Inc All rights reserved All information in this manual is subject to change without notice No part of the document may be reproduced or transmitted in any form or by any means electronic or mechanical including photocopying or recording without the express written permission of AJA Inc Contacting Support When calling for support have all information at hand prior to calling To contact AJA Video for sales or support use any of the following methods Telephone 41 530 271 3190 FAX 1 530 271 3140 Web http www aja com Support Email support aja com Sales Email sales aja com KUMO v3 1 5 www aja com Chapter 1 Introduction Rear Panel 1604 Rear Panel 1616 Typical Front Panel Control Panel Option Rear Panel 3232 Overview KUMO v3 1 a s ET KUMO Mee ALAN umm mum mum Nu KUMO had Fo C q utDOUDIDOO LAN i INPUTS e Ph INPUTS sd A h Es Wc C
65. porary You will later need to restore the original settings on your computer 3 Connect the Windows XP PC to KUMO s RJ 45 port either direct or through your LAN 4 Point your web browser to 192 168 101 1 as the web address These are the KUMO temporary static IP addresses 5 Once connected to KUMO s web interface reconfigure KUMO s network parameters as desired 6 Restore your computer to its normal network settings using this procedure and the IP addresses you recorded earlier Larger System Control Configurations KUMO v3 1 This section describes a KUMO system network configuration that is part of a large LAN WAN TCP IP networking DHCP or Static IP and any number or combination of KUMO routers KUMO control panels and web browser computer control If the KUMO will be attached to a WAN talk to your IT administrator and obtain the details on how he she wishes you to configure the KUMO DHCP or static IP Manually connecting to a network you will need to configure the KUMO IP CONFIG IP ADDR IP MASK and IP GATEWAY parameters according to the information obtained from your IT administrator 31 www aja com Figure 25 KUMO and KUMO CP with Web Browser UI Control KUMO CPs ae PP 8989998888988898 8899898888988888 KUMO Routers d Multiple KUMO Routers Web Browser aso User Interface Each KUMO CP can control up to 4 KUMO routers at a time TCP IP Network KUMO supports t
66. r Print Services for Windows software and the DNSSD for Firefox add on software If you have iTunes running on your PC the Apple Bonjour software will already be installed If necessary download and install the Apple Bonjour software 1 The Apple Bonjour Print Services for Windows software can be downloaded from http support apple com kb DL999 Figure 14 Apple Bonjour Download Website Firefox Bonjour Print Services for Windows v2 0 2 supportapple com kb DL999 C Yahoo D Most Visited Getting Started Customer Log In Box Google IceWarp Web Mail Suggested Sites Web Slice Gallery 5 iTunes Support e Bonjour Print Services for Windows v2 0 2 tese English k b i Download oJ Bonjour Print Services for Windows lets you discover and configure Bonjour enabled printers from your Windows computer using the Bonjour Printer Wizard Use Windows Update to make sure you have the latest Service Pack installed for your computer Printer requirements Bonjour Print Services works with either network printers over Wi Fi or Ethernet USB printers shared via a Mac or an AirPort base station Firewall requirements The Bonjour networking protocol sends and receives network packets on UDP port 5353 The Bonjour installer will configure the Windows firewall appropriately during installation on supported systems but if you have a separate personal firewall enabled
67. raditional TCP IP networking through DHCP or Static IP addressing Connection IMPORTANT When using KUMO in a DHCP or Static IP addressed network it is best to select and maintain a consistent network scheme If a mixture of DHCP and Static IP addresses are used inconsistent performance can result The most stable operation is achieved when all IP addressing is either DHCP or Static Default DHCP DHCP is the default initial configuration routine for KUMO devices If you start up on a Configuration DHCP network KUMO will accept assigned IP addresses After DHCP initialization use your zeroconf browser to view the KUMO webpage and view the assigned IP address Static IP Configuration If your IT administrator prefers an assigned IP address that is fixed called a Static IP you will need to set network parameters using the KUMO UI Network page where you will enter IP address type Static IP e a unique IP address e the Subnet Mask and default gateway IP address your LAN s internet router KUMO v3 1 32 www aja com Figure 26 KUMO User Interface Network Tab HOME CONFIGURATION Click IP Address Text to Edit System Name IP Address Type IP Address Netmask Default Gateway MAC Address Update Network Settings NETWORK FIRMWARE ALARMS IDENTIFY Reference 1080i 29 97 KUMO3232 559 DRCP y 10 9 250 19 255 255 0 0 10 9 0 2 00 0C 17 0D 80 3B Update Network Settings VIDEO SYSTEMS WARNING When you
68. rce20 Source21 Source22 Source23 Source24 Source25 Source26 Source27 Source28 Source29 Source30 Source31 Source32 DESTINATION 2 3 5 6 7 8 9 10 11 12 13 14 15 E Dest3 Dest4 Dest5 Dest6 Dest Dest8 Dest9 Dest10 Dest11 Dest12 Dest13 Dest14 Dest15 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Dest17 Dest18 Dest19 Dest20 Dest21 Dest22 Dest23 Dest24 Dest25 Dest26 Dest27 Dest28 Dest29 Dest30 Dest31 Introduction An optimized web server inside the KUMO allows you to remotely monitor and adjust parameter settings via a network attached computer running a web browser The network can be a closed local area network a straight computer to KUMO Ethernet cable or even exposed through a firewall to a broadband WAN not generally recommended since anyone on the internet can then access the KUMO The LAN connection on the KUMO uses a standard RJ45 connector and communicates via standard straight through CAT 5 Ethernet cables or null modem cross over cables without any configuration or strapping required NOTE In this chapter a KUMO 3232 is used as the example Other models will have fewer buttons Navigation Bar The KUMO web browser user interface Ul provides a navigational bar of tabs for access Information to five control screens and the Identify toggle button e Home control panel for source destination selections e Configuration custom naming for sources and destinations and mode selection e Network IP setti
69. re 3 KUMO Router Direct Connection to KUMO CP or Mac PC KUMO CP KUMO Router Direct Cat 5 ethernet cable connection KUMO Router Web Browser User Interface LAN Connection In a LAN connection one or more KUMO routers KUMO control panels and web browser Using a Hub or equipped computers are connected to your LAN or closed network using Cat 5 Ethernet Switch cable and an Ethernet hub or switch Figure 4 KUMO LAN with Routers Control Panels and Web Browser UI 8988888 TE JN 888898 Cat 5 Ethernet Cabling Ethernet Switch Up to 4 KUMOs per Control Panel Web Browser User Interface Default Network KUMO routers and control panels ship with DHCP enabled making system operation Settings possible simply by connecting the KUMO device s Ethernet cabling In addition temporary default static IP addresses can be activated for initial KUMO system configuration See KUMO Temporary Static IP Address on page 16 KUMO v3 1 10 www aja com In This Manual Chapter 1 Introduction lists features and gives a general description of the product Chapter 2 Installation details KUMO installation connections and networking configuration options from closed to WAN wide area networking Chapter 3 Web Browser User Interface provides complete instructions for controlling and monitoring the KUMO router from a computer Chapter 4 KUMO Remote Control Panel details the configuration and operation of th
70. rmware Completed Successfully Version 3 0 0 6 Restart KUMO With New Firmware Once these steps are complete the KUMO will be running the software you just uploaded until the next time you upgrade it The configuration of the KUMO prior to the upgrade is preserved KUMO v3 1 40 www aja com Safeboot Reset KUMO Alarms KUMO v3 1 NOTE NOTE Verify the new software is running by bringing up the KUMO web page again Check the Firmware page for the current version number The restart and refresh cycle may take a couple minutes If for some rare reason it didn t update you can then run through the update steps again On some browsers the Retry page may appear even though the software upgrade was successful If this occurs before clicking on retry refresh the web page and check the version number If the new version number appears at the top of the page the software upgrade was successful If the old version appears click Retry If there is a power outage or glitch during the software download the KUMO will boot the older software version and the upgrade process can then be re started by the user This happens because the KUMO has been designed with a safety feature where an internal safe copy of the previous software is retained in the event the updating process fails If your KUMO software becomes corrupted to the point of freezing the device you can always reset to the initial factory installed safeboot firmwar
71. s What s In The Box When you unpack your AJA KUMO SDI router you ll find the following components e KUMO Chassis or KUMO CP option e AC adapter and AC power cord The manual you re reading on CD Please save all packaging for shipping KUMO should you wish to do so when moving or sending it in for service KUMO v3 1 12 www aja Mm Figure 5 KUMO Shipping Box Contents Installation and Operation Manual KUMO Router shown or KUMO CP Control Panel in electronic form on the CD PDF S KUMO Chassis installation Where to Place KUMO Physical Requirements Router Dimensions Power Requirements KUMO v3 1 Plan adequate space for cable routing from the back of the router chassis Ensure that SDI video cable connectors will not be stressed and that cables are not bent or crimped in the process When rack mounting or stacking multiple KUMO chassis ensure there is adequate airspace for cooling around the KUMO units Note the location of cooling vents on all equipment next to the KUMO and ensure none are obstructed When planning equipment locations and mounting methods take into account the size of the router chassis 1 RU Height 1 75 4 45 cm Depth 1 5 3 81 cm Width 19 48 3 cm e 2 RU Height 3 47 8 814 cm Depth 1 543 3 92 cm Width 19 48 3 cm Input Voltage 110 220VAC 50 60Hz to 12 VDC brick converter supply fully redundant with optional second brick supply AJA reco
72. s Add or Remove Programs Screen E Control Panel Currently installed programs nda autro EE 3 Change or TI D Name 0 vj 7 Remove i Windows Installer 3 1 KB893803 Programs Click here For support information To remove this pr an ce a M e e Windows Components Wizard L g F Add Mew Networking Services Programs To add or remove a component click the check box A shaded bos means that only part m of the component will be installed To see what s included in a component click Details J addiRemove subcomponents of Networking Services window g Internet Gateway Device Discover and Control Client 0 0 MB Components O a Peer to Peer a RIP Listener y O Ji Simple TCP IP Services Set Program l a UPnP User Interface Check this Box Access and Defaults Description Allows you to find and control Internet connection sharing hardware and software that uses UPnPIT M Total disk space required 54 8 MB Space available on disk 434 78 0 MB Details 3 Inthe Windows Components Wizard click Networking Services and then click the Details button below You ll see a Networking Services dialog locate the UPnP User Interface checkbox and click in it to check the box and enable UPnP service 4 Click the OK button and then click Next in the Windows Components Wizard You may need to provide your Windows XP installat
73. s sont tomb s dans l appareil que l appareil a t expos la pluie ou l humidit ne fonctionne pas normalement ou est tomb Warnung Das Ger t sollte nur von qualifizierten Fachkr ften gewartet werden Eine Wartung ist f llig wenn das Ger t in irgendeiner Weise beschadigt wurde wie bei besch digtem Netzkabel oder Netzstecker falls Fl ssigkeiten oder Objekte in das Ger t gelangen das Ger t Regen oder Feuchtigkeit ausgesetzt wurde nicht ordnungsgem funktioniert oder fallen gelassen wurde Advertencia Consulte al personal calificado por cuestiones de reparaci n El servicio de reparaci n se requiere cuando el dispositivo ha recibido cualquier tipo de da o por ejemplo cable o espigas da adas se ha derramado l quido o se han ca do objetos dentro del dispositivo el dispositivo ha sido expuesto a la lluvia o humedad o no funciona de modo normal o se ha ca do Aviso Remeta todos os servicos de manutenc o para o pessoal de assist ncia qualificado A prestac o de servicos de manutenc o exigida quando o dispositivo foi danificado mediante qualquer forma como um cabo de alimentac o ou ficha que se encontra danificado a quando foi derramado l quido ou ca ram objectos sobre o dispositivo quando o dispositivo foi exposto a chuva ou a humidade quando n o funciona normalmente ou quando foi deixado cair Avviso Fare riferimento al personale qualificato per tutti gli interventi di assistenza L assistenz
74. t 5 between the RJ45 connectors on both devices Figure 11 KUMO Direct Connection to Mac PC Web Browser or KUMO CP to KUMO KUMO CP KUMO Router Direct Cat 5 ethernet cable connection KUMO Router Web Browser User Interface The KUMO CP Auto Configure assigns Router Select Button 1 to the attached router LAN Connection In a LAN connection connect one or more KUMO routers to your LAN or closed network Using a Hub or using Cat 5 Ethernet cable and an Ethernet hub or switch then power up the equipment Switch KUMO v3 1 19 www aja com Setup and Control Methods KUMO v3 1 Figure 12 KUMO LAN with Web Browser UI LAN only system use TCP IP to configure routers and devices a m 1 Use Bonjour or configure KUMOs e TCP IP settings 2 Control KUMOs from a web a browser a Control Unlimited KUMO Routers via TCP IP LAN Web Browser User Interface Regardless of direct connection or LAN connection KUMOs are controlled over a network by connecting to KUMO s internal webserver with a standard web browser on a Mac or PC To do this you first need to establish a network connection between the computer and the KUMO to be controlled There are various methods supported for doing this depending on the operating system and or web browser being used Choose one of the following quick start procedures that best fits your environment each proce
75. t 74 Configuration page KUMO CP 46 Configuration screen 36 connector power 7 reference BNC 8 RJ45 8 RS 422 8 control panel identify 46 control panel resets 14 cooling airspace 13 cooling vents 13 custom lens chips 44 D deactivate alarms 42 default IP address temporary 17 default static IP address procedure 17 Destination hide 38 lock 38 64 shifted selection 45 Destination buttons 36 Destination Lock 44 DHCP 78 32 default setting 10 14 32 dimensions router 13 direct connection auto configuration 14 direct network connection 9 Display Intensity 46 DNS server 18 DNSSD accessing KUMO devices 26 Firefox installation 24 icon 25 Download 39 Dual mode BNC connector 8 37 E equipment interconnect steps 14 error condition 47 F factory default static IP address 17 features 7 Firefox device access with DNSSD 26 firmware version 38 G GVG Native Protocol 9 49 H hide Destination 38 Home page KUMO CP 45 Home screen 36 ID LED 8 Identify button 42 46 Identify LEDs 42 inputs video 8 installation summary 12 installing software 39 IP address 18 temporary default 17 IP Reset 45 www aja com KUMO v3 1 K KUMO assign to KUMO CP with web browser 33 selecting from web browser 33 KUMO CP general description 43 L LAN 78 LAN connection 70 lens chips 44 lock Destination 38 M MAC address 38 46 Manual 17 mounting methods 13 multi router network 43 N naviga
76. tion bar 35 network auto discovery 15 network configuration larger systems 29 31 Mac Safari and Bonjour 15 Mac Safari and static IP 27 overview 18 Win 7 and UPnP 76 Win 7 browser and static IP 26 Win 7 Firefox Bonjour 23 Win XP and UPnP 28 Win XP browser and static IP 29 Win XP Firefox Bonjour 29 network configuration overview 9 network connection direct 9 19 LAN 70 19 network connection methods 20 Network page KUMO CP 46 network setting default 70 Normal mode BNC connector 8 O outputs video 8 Over Temperature 41 overview 6 P packaging 72 65 Panel Lock 44 placement 13 power connector 7 power consumption 73 power requirements 73 power supply brick 7 product features 7 product overview 6 Q Quad mode BNC connector 8 37 R redundant power supplies 72 60 REF BNC 8 remove Destination lock 44 Reset Auto Configure 46 Reset button pinhole 8 Reset Buttons 45 RJ45 connector 8 Router Delegation Buttons 43 44 45 RS 422 adapter 9 RS 422 connector 8 S Safari browser 15 Safeboot Reset 47 45 safety 12 setting factory default static IP address 17 Shift DEST 45 Shift SRC 45 shipping box contents 72 Signal switching mode 36 Source shifted selection 45 Source and Destination names 44 Source buttons 36 standard TCP IP network 18 static IP 32 63 static IP configuration 32 Suppress 42 System Name 38 46 T TCP IP 32 TCP IP setup fields 38 46 U update files 39 Update Net
77. tions Internet Options A 4 2 install Codd Local Area Connection 3 Properties IPv4 Connectivity IPv6 Connectivity Media State Connect using Duration Speed gt Intel R PRO 1000 EB Network Connection with 1 0 Acce You can get IP settings assigned automatically if your network supports This connection uses the following items 2 pe Don brazo aa to ask your network administrator DM Client for Microsoft Networks di QoS Packet Scheduler dS File and Printer Sharing for Microsoft Networks Obtain an IP address automatically Use the following IP address J amp Intemet Pro ersion 6 ICP IPvb NU eare II Intemet Protocol Version 4 TCP IPv4 IP address ae 4 Link Layer Topology Discovery Mapper IMD Driver Subnet mask 2 453 408 2 850 554 4 Link Layer Topology Discovery Respond Default gateway Po Properties pus ua ma imss Obtain DNS server address automatically Description 9 Use the following DNS server addresses Transmission Control Protocol Intemet Protocol The default wide area network protocol that provides communication Preferred DNS server across diverse interconnected networks Alternate DNS server Validate settings upon exit C In the resulting General dialog screen select the Properties button D Then on the Networking tab select Internet Protocol Version 4 and click the Properties button below E Finall
78. tup and Control from a Browser on Windows 7 sese 22 Windows 7 Using UPnP Universal Plug and Play o oooooooo o 23 Windows 7 Firefox Using Bonjour se e e e I 23 KUMO v3 1 2 www aja com Install Apple Bonjour Print Services for WindowS oooooommmo oo 23 Install DNSSD for Firefox Add On sss 24 Accessing KUMO Devices in Firefox e ccc cece cece eee eneeees 26 Windows 7 Browser Type in KUMO Static IP Address oooooooooom 26 Setup and Control from a Browser on Windows XP c e cece eee eee eeees 28 Windows XP using UPnP Universal Plug and Play 28 Enabling UPnP Services in Windows XP cece ccc cece cece eee eeeees 28 Windows XP Firefox Using BONjOUr ccc ccc ec eee I II 29 Windows XP Browser Type in KUMO Static IP AddressS o oo o 29 Larger System Control Configurations 0 ccc cece eee eee e teen ene ee eens 31 TCP IP Network Connection 0 cece ccc sarit eect hh 32 Default DHCP Configuration sss 32 Static IP Configura oO isos cada an Rc ardeo d rad docta 32 Select KUMO to Control from Webpage ccc e e carro 33 Assign KUMO CP to Control KUMO Routers sseeeeeeee ne 33 Chapter 3 KUMO Router Web Browser User Interface 35 io o EEE E AEE uae teen nae 35 Navigation Bar Information e e cece rro 35 KUMO OMe T
79. use downstream equipment depending on the characteristics of the SDI receiver s to react to the switch for example a monitor glitch or roll It is also possible that switching anomalies can appear on just one or more outputs in the same group in the Dual and Quad modes This effect occurs regardless of the relative timing of the SDI signals being switched or any reference input connected to the router 48 www a KUMO CP Specifications Control Environment Power KUMO CP Size KUMO CP Weight e 10 100 1000 Ethernet RJ 45 internal Linux OS web server Operating Termperature 0 to 40 Degrees C e Relative Humidity 0 to 90 non condensing 100 240 VAC 50 60Hz 9 17 VDC 12 VDC nominal optional redundant power supply KUMO CP 4 Watts 0 4A at 12VDC Depth 1 07 27 3 mm Height 1 72 43 7 mm Width 19 483 mm 1 2 lb 55 kg GVG Native Protocol Support Introduced with v2 0 firmware KUMO provides basic support for the GVG Native Protocol aka Series 7000 Native Protocol GVG Native Protocol using 1 serial connection via RS 422 with a 9 pin connector e TCP ethernet for up to 10 connections For for information refer to Grass Valley documentation at http www grassvalley jp pdf RoutingProductsProtocolManual 2 pdf NP Commands Supported Background KUMO v3 1 BK Connect heartbeat BK N Gets system name BK T Gets Software Title BK t Gets Protocol Software BK R
80. ware update files are ZIP files which you can open with a number of standard and third party uncompressor applications The software image that you ll install on KUMO is a file with a name similar to e kumo ver 1 1 1 1270485530 bin NOTE Depending on your PC or Mac operating system settings the bin extension may not be visible to you in a file directory Uploading and Uploading and installing the software update only requires a PC or Mac that can see the Installing Firmware to KUMO via its browser Follow this procedure to install the software KUMO Point your browser at the downloaded KUMO upgrade file on your computer by clicking on the Browse button on the Firmware screen HOME CONFIGURATION NETWORK FIRMWARE ALARMS IDENTIFY Reference 10801 29 97 ines KUMO3232 559 M Current Firmware Version 3 0 0 0 File Upload OO m KUMO Manuals v3 0 WIP SoftwareDevelopment y 4 Search SoftwareDevelopment Organize v New folder Upload New Firmware Browse E Pictures EX lt B Videos x LLL WARNING You are uploading new firmwa _ kumo ver 3 0 0 6 1377295908 bin 8 26 2013 12 44 PM the firmware will be displayed ias 1 Ly AJAKenWorkPC de AJA Glossary S You will then be asked if the firmware shoul After the firmware has been committed to fl d KUMO Manual remain as they are now de Art do ArtObsolete Upon confirming a reboot you will be redirg de PDF start working again Th
81. work Settings 38 46 updates 38 upload 39 UPnP 9 18 www aja com KUMO v3 1 V video inputs 8 video outputs 8 video reference signal 47 W WAN 31 web browser control capabilities 78 web browsers supported 78 web server 35 Z zeroconf 18 Zero configuration Bonjour Protocol 9 ZIP files 39 66 www aja com
82. y click the Use the following IP address radio button and enter the IP Address and Subnet Mask below e IP Address 192 168 101 X do not use 1 in the last octet e Subnet Mask 255 255 255 0 F Click the OK button to store the changes NOTE The previous step is temporary You will later need to restore the original settings on your computer 3 Connect the Windows 7 PC to KUMO s RJ 45 port either direct or through your LAN KUMO v3 1 27 www aja com 4 Point your web browser to 192 168 101 1 as the web address This is the KUMO temporary static IP address 5 Once connected to KUMO s web interface reconfigure KUMO s network parameters as desired 6 Restore your computer to its normal network settings using this procedure and the IP addresses you recorded earlier Setup and Control from a Browser on Windows XP Windows XP using UPnP Universal Plug and Play Enabling UPnP Services in Windows XP KUMO v3 1 The easiest methods of setting up and controlling a KUMO router from a PC running Windows XP are e Setup and Control from a Browser on Windows XP using UPnP Setup and Control from a Firefox Browser on Windows XP using Bonjour Setup and Control from a Browser on Windows XP using a Static IP Address Windows XP PCs support UPnP protocols though very often UPnP service is disabled asa default The procedure to enable UPnP is given later in this topic If UPnP is enabled you can control KUMO routers by s
83. you will need to ensure that UDP port 5353 is open for Bonjour to work correctly What s included This package installs the Bonjour Printer Wizard in Program Files Bonjour Print Services and creates a shortcut on the Desktop Providing Feedback If you have specific product feedback visit http www apple com feedback bonjour html 23 www aja com 2 Click on Download and then save and run the download Follow the installation instructions Figure 15 Bonjour Print Services Installation Screen X E Bonjour Print Services x Welcome to the Bonjour Print Services Installer You will be guided through the steps necessary to install Bonjour Print Services To get started click Next Install DNSSD for With Apple Bonjour installed download and install the DNSSD for Firefox add on Firefox Add On 1 TheFirefox add on software can be downloaded from dnssd me Figure 16 DNSSD Website fj dnssd me DNS Service Discovery Apps dnssd me Most Visited Getting Started Customer Log In Box L Google iu IceWarp Web Mail e Suggested dnssd me DNS Service Discovery Apps Tools and Info DNSSD for Google Chrome and Mozilla Firefox This extension provides quick and easy access to DNSSD advertised websites from within Google Chrome and Mozilla Firefox Requirements Mac OS X No additional software necessary Windows Apple Bonjour have iTunes It s already installed Insta
84. your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet Avertissement La s curit de la prise polaris e ou de la prise de type mise a la terre ne doit en aucun cas tre emp ch e de fonctionner Une prise polaris e a deux broches l une tant plus large que l autre Une prise de type mise a la terre a deux broches et une troisi me broche pour la mise la terre La broche large ou la troisi me broche sont fournies pour votre s curit Si la prise fournie ne s ins re pas dans votre prise femelle consultez un lectricien pour le remplacement de la prise femelle obsol te Warnung Der Sicherheitszweck des gepolten bzw Schukosteckers ist zu ber cksichtigen Ein gepolter Stecker verf gt ber zwei Pole von denen einer breiter als der andere ist Ein Schukostecker verf gt neben den zwei Polen noch ber einen dritten Pol zur Erdung Der breite Pol bzw der Erdungspol dienen der Sicherheit Wenn der zur Verf gung gestellte Stecker nicht in Ihren Anschluss passt konsultieren Sie einen Elektriker um den veralteten Anschluss zu ersetzen iAdvertencia No eche por tierra la finalidad del tipo de enchufe polarizado con conexi n a tierra Un enchufe polarizado tiene dos espigas una m s ancha que la otra Un enchufe con conexi n a tierra tiene dos espigas iguales y una tercera espiga que sirve para la conexi n a tierra La expiga ancha o la tercera espiga sirven