1. gt SUMMERAIRE aie ae Built Better to Last Longer USER MANUAL SLO SFLO115 SERIES OIL FIRED WARM AIR FURNACES Save These Instructions For Reference ALL SUMMERAIRE SLO115 SFLO115 MODELS ARE AIR CONDITIONING READY NOTICE TO HOMEOWNER THIS FURNACE SHALL BE INSTALLED BY A CERTIFIED INSTALLER AND WHERE REQUIRED BY LAW A LICENSED TECHNICIAN NOTICE TO HOMEOWNER IF YOUR SUMMERAIRE SLO SFLO SERIES OIL FURNACE HAS BEEN INSTALLED USING THE APPROVED SS1 C TJERNLUND SIDEWALL POWER VENTOR IT IS YOUR RESPONSIBILITY TO KEEP THE AREA AROUND THE OUTSIDE TERMINAL OF THE POWER VENTOR CLEAR OF SNOW ICE AND DEBRIS FOR SERVICE CALL INSTALLATION INFORMATION Installing Contractor Telephone Number Unit Model Number Unit Serial Number Installation Date Summeraire Mfg Peterborough Ontario K9J 7B1 OCT 2007R OPERATING INSTRUCTIONS CAUTION NEVER BURN GARBAGE REFUSE OR PAPER IN THE HEATING UNIT NEVER LEAVE COMBUSTIBLE OR OTHER MATERIALS AROUND OR NEAR THE FURNACE IDENTIFY THE LOCATION OF YOUR BURNER FURNACE POWER SWITCH OIL BURNER OPERATING INSTRUCTIONS e Use No 2 furnace oil ONLY e Do not use gasoline crankcase oil or any oil containing gasoline Do not attempt to start the burner if excess oil has accumulated when the furnace is full of vapor or if the combustion chamber is hot e Press the burner relay reset button ONLY TWICE if the burner fails to start call an Oil Burner Technician e
2. SUMMER FAN OPERATION BELT DRIVE During the summer months continuous air circulation can be obtained by pulling sliding the manual fan switch from the Auto position to the On position DUAL AIR OPERATION BELT DRIVE Furnaces equipped with a dual 2 speed blower system enable partial air circulation at all times When thermostat calls for heat the burner starts and the high speed phase quickly distributes warmed air throughout the house When the high speed phase ceases the low speed continuous circulating air to even the temperatures DUAL AIR OPERATION DIRECT DRIVE If your SLO115 or SFLO1I15 furnace is equipped with a DIRECT DRIVE blower assembly The burner starts and the high speed phase quickly distributes warmed air throughout the house When the high speed phase ceases the low speed phase continues circulating the air to even the tempera tures throughout the house If the low speed feature is not required operate the small rocker switch located on the power junction box Low speed will not operate AIR FILTER This furnace should never be operated without filters A DIRTY AIR FILTER CAUSES INEFFICIENCY AND HIGHER OPERATING COSTS Clean or replace filters each heating season or as required Filter specifications for the air filter installed in your Summeraire oil fired warm air furnace are listed below DO NOT SUBSTITUTE Note Changing the typ
3. Ifthe oil burner is to be shut off for any period of time shut the oil valve OFF at the oil tank e Do not adjust or tamper with the furnace or any of the controls e Do not burn garbage or paper in this unit e Never leave paper rags or other combustibles around the furnace e Only qualified or where required by law a licensed technician shall set up this unit and adjust controls e DO NOT START THE OIL BURNER UNLESS THE BLOWER DOOR IS SECURED IN PLACE TO TURN THE BURNER OFF e Turn the main oil burner switch to OFF e Set the thermostat as far below room temperature as possible IF BURNER IS TO BE SHUT OFF FOR AN EXTENDED PERIOD e Turn main oil burner switch to OFF e Close all oil supply valves e The heating system should be checked and cleaned if necessary RESTARTING BURNER AFTER EXTENDED SHUT DOWN The complete oil burner should be checked and serviced by a qualified technician e Check oil pump strainer e Replace oil filter cartridge e Check electrodes e Oil burner motor see lubrication section e Restart burner by following instructions in STARTING THE OIL BURNER section e If your furnace has been shut off for an extended period contact your qualified service technician for Start up BURNER FAILS TO OPERATE Always call a qualified technician The trouble may be e Raise your thermostat to 5 C 10 F above present room temperature e Make sure your Oil Burner po
4. e or size of filter used in your Summeraire furnace can seriously affect the operation of the furnace AIR FILTER SPECIFICATIONS Filter size 20 X 20 X 1 CSA or ULC Certified Approved Type Throw away disposable USE OF FILTERS OTHER THAN THOSE SPECIFIED ABOVE CAN CAUSE DANGEROUS ELEVATION OF FURNACE TEMPERATURES THIS IS AN UNSAFE CONDITION DO NOT USE INSTALL PLEATED TYPE AIR FILTERS IN THIS FURNACE WARNING Your furnace requires Combustion Air DO NOT close off furnace room or enclose furnace this will starve to furnace oil burner for air necessary for combustion and could result in a dangerous situation NOTE IF YOUR SUMMERAIRE FURNACE IS INSTALLED WITH A SS1 C TJERNLUND POWER VENTOR IT IS THE USERS HOMEOWNERS RESPONSIBILITY TO KEEP THE AREA AROUND THE VENT TERMINAL FREE OF ICE SNOW AND DEBRIS 4 F SLO SFLO USMAN EN REV2
5. leaned and adjusted see oil burner manual supplied with the oil burner LUBRICATION Apply 2 3 drops of SAE 20 30 Non Detergent oil ONLY to the oil port s located at either end of the burner motor Apply 2 3 drops of SAE 20 30 Non Detergent oil ONLY to the oil ports located at either end of the blower motor DO NOT OIL THE FAN BEARINGS CLEANOUTS SLO115 Remove cleanout panel and cap from the front panel Loosen soot from the radiator with a cleaning tool or brush The tool should bend allowing cleaning of the curved surfaces of the heat exchanger To clean the rear of the radiator remove the chimney flue pipe from the furnace flue pipe Remove the baffle from the furnace flue pipe Loosen the soot from the rear of the heat exchanger flue pipe and baffle SFLO115 Remove one of the cleanout panels and cap located on the side panels It is only necessary to remove one of the cleanouts Also remove the chimney flue pipe from the furnace Loosen soot from radiator with a cleaning tool or brush The tool should bend allow cleaning of the curved surfaces of the heat exchanger Remove all loose soot with a vacuum cleaner suitable for this purpose Inspect passages to check for missed areas When reinstalling the cleanout cap make sure you replace the gasket 3 NOTE WE RECOMMEND THAT A QUALIFIED MECHANIC OR WHERE REQUIRED BY LAW A LICENCED MECHANIC ONLY SHOULD PERFORM ALL SERVICE AND CLEANING OF YOUR SUMMERAIRE FURNACE
6. wer switch is in the ON position e If you hear a hum from the oil burner and the motor has not started press the reset button on the burner motor once only e Blown fuse tripped breaker in electrical panel e Thermostat may be set below room temperature e Burner relay combustion control may have to be reset press reset twice only e Oil valve may be closed e Oil supply may be too low e Manual reset fan and limit control may be tripped e Blocked flue sensor tripped e If the oil burner fails to start or runs for only a few seconds call a qualified service technician OIL FURNACE ANNUAL SERVICE The oil burner and furnace should be thoroughly cleaned and serviced annually by a qualified service tech nician and where required by law a licensed technician CAUTION Do not use any commercially available soot remover Use extreme caution when servicing since the combustion chamber is fragile Routine cleaning of the flue passages does not require cleaning the combustion chamber If for some reason it is necessary to work in the area of the combustion chamber do not touch or alter the chamber position Before cleaning shut off electrical power supply to the furnace Note Always keep oil supply valve shut off if burner is shut down for an extended period of time The nozzle should be replaced annually handle nozzle with care so that the inside surface tip is not scratched The electrodes should be c