Home
        Quick Configuration Guide
         Contents
1.      3 B i he Model PTU D47    Motion Control Systems    This Configuration Guide lists the configuration options and accessories for the PTU D47 pan tilt units   PTU D47  manufactured by FLIR Motion Control Systems  Inc  Additional information and instructions for  the PTU D47 are available in the following documents     e PTU D47 Datasheet  e PTU D47 User Manual    e  Pan Tilt Unit Command Reference Manual    Model Numbers     gt    5 9  S9       Wiring  S   Standard    Pan Tilt  SS   Std             A   Pass through           SS denotes standard pan tilt range of motion  Other lettering denotes alternate pan andor tilt range of motion     Available Options    The following configuration and options are available for the PTU D47   e Payload Wiring  The PTU D47 may be ordered with or without payload pass through wiring  Page 2   e Range of Motion  If needed  you may request special limits  Page 3     e Pan Tilt Controls  The PTU D47 can be controlled using an ASCII command set  Ethernet web connec   tion  external joystick  or binary command set  Page 4     e Accessories  Available accessories include cables  converters  power supplies  and starter kits  Page 5     Page 1 of 7  890C Cowan Road  Burlingame  CA 94010 e Office  650 692 3900 e Fax  650 692 3900   e MCS flir com    www flir com MCS  03 2013    PTU D47 Series    Payload Wiring   The D47 is available with pass through wiring to carry video   power  and other signals to the payload  Pass through wiring  consists of 
2.  D47 with custom hard stops installed and or with  A custom bracket positioning  factory ranges of motion  etc  Please contact FLIR Motion  Control Systems  Inc  for assistance     Note  The PTU D47 supports tilt axis limits of  80   to  31   with extended range     Pan Range Options Tilt Range Options  Part Number  D47 SS __ 000  _ Part Number  D47 SS __ 000 _     The part number on your PTU D47 may vary as shown here to reflect any special ordered custom limits   stops  etc     Page 3 of 7    890C Cowan Road  Burlingame  CA 94010 e Office  650 692 3900 e Fax  650 692 3900 e MCS flir com    www flir com MCS  03 2013    PTU D47 Series Configuration Guide    Pan Tilt Controls    PTUs support serial  Ethernet web  binary  and joystick control interfaces that provide a wide range of  system control architectures  The following options are available     ASCII Command Set   Your PTU can be controlled via the standard a n  built in serial port  RS 232 or RS 485  using ppe zntelitest fodi  simple ASCII commands   See the Command Pe   current Pan position is 0    Reference Manual   This can be done using a  terminal program or a custom application        Ethernet Web Interface  amp  GPM    Your PTU can be controlled via Ethernet IP  using the Geo Pointing Module  GPM   which  includes a simple web based interface for PTU  control and configuration from a mouse and  entered commands  The GPM also allows PTU  control using latitude  longitude  and altitude  commands   See the Geo Point
3.  PTU CAB EXT 100  100           Page 7 of 7    890C Cowan Road  Burlingame  CA 94010 e Office  650 692 3900 e Fax  650 692 3900   e MCS flir com    www flir com MCS  03 2013    
4.  ordered for your PTU  These accessories simplify system prototyping  and fielding     Breakout Cables    The breakout cable connects to the 19 pin base connector   MIL C 26482  on the PTU and terminates to standard connec   tors for power  serial communication  and payload signals  The  terminating connectors are  Power  DIN   2x video  composite    RS 232  DB 9  female   RS 485  RJ11   and payload pass through  conductors  Length  25        Part Number  PTU CAB 25BO       Power Supply  PTU power supply unit  30VDC output  110 220VAC input     Dimensions  3 44   W x2 01   Hx7 61   L   Part Number  PTU APS 30V NA  North America  or  PTU APS 30V EC  Europe     mum speed of the unit by an amount that is propor       Note  Input voltages under 30V can reduce the maxi   E  tional to the voltage difference        Starter Kit    The PTU starter kit includes one power supply  PTU APS 30V   one 25    breakout cable  PTU CAB 25BO    and one USB to RS 485 adapter cable  PTU CONV USB RS485    Part Number  D47 KIT S TR NA  North America  or   D47 KIT S TR EC  Europe       Note  Input voltages under 30V can reduce the maximum speed of the unit by an amount that  is proportional to the voltage difference     Page 5 of 7  890C Cowan Road  Burlingame  CA 94010 e Office  650 692 3900 e Fax  650 692 3900   e MCS flir com    www flir com MCS  03 2013    PTU D47 Series Configuration Guide    Mating Connector    Mating connector for the 19 pin base and payload connectors   MIL C 26482  PTU connec
5. flying leads that extend from the base of the PTU  and are then wired externally to the payload  This option sim   plifies and streamlines external cabling       Note  The PTU D47 is not available with a slip  A ring and is therefore incapable of continuous   360    pan axis rotation     Standard    The PTU D47 comes standard with no payload pass through  wiring     Part Number  D47 SS SS O00 __    Pass Through Wiring    This option adds flying leads that allow you to route signals to       Ne Base Connector    Pass Throughs  flying leads     the payload mounted on the PTU D47 as shown in the following table     No Flying    Pass Through    Leads      of conductors    Passed Through  Power 0  Video O  General 0  Total 0  Base Connector  RS 232 Host Control YES  RS 485 Host Control YES  Part Number  D47 SS SA 000 __  Page 2 of 7    Co  A  N  N    YES  YES    890C Cowan Road  Burlingame  CA 94010 e Office  650 692 3900 e Fax  650 692 3900 e MCS flir com    www flir com MCS    03 2013    PTU D47 Series    Range of Motion    The PTU D47 has the following standard factory pan and tilt axis limits  Factory limits define the range of  motion allowed for an axis when limits are enabled  and that axis cannot travel beyond those limits You  may also order a PTU D47 with an optional slip ring that allows continuous 360   pan axis movement  see    Page 3    47o  31         TILT AXIS   47  TO  31          PAN AXIS    159         180   EXTENDED RANGE       Note  You may special order a PTU
6. ing Module  Users Manual               Ethernet    Part Number  PTU DGPM  Binary Command Set  C API     Your PTU can also accept binary commands  using the optional C Language Binary Com   mand Set  PTU CPI   which is provided as ANSI  C Source Code that you can compile into your  application on most computing platforms   CPU OS   The binary command format is rec   ommended for high performance applications  such as tracking           Part Number  PTU CPI  Gamepad Controller    A USB gamepad controller is available to con   trol a single PTU and up to two VISCA compati   ble cameras that are connected to a host  computer via a serial connection  The PTU Joy   stick Control utility is included with PTUs     SERIAL       Part Number  PT PSC    to the host PC using a dedicated serial    Note  Cameras should be connected  connection for each camera     Page 4 of 7  890C Cowan Road  Burlingame  CA 94010 e Office  650 692 3900 e Fax  650 692 3900   e MCS flir com    www flir com MCS  03 2013      M ma Fx u ff E   FE BERLE d s o ier f    A BB   A a  PTU D47 Series Configuration Guide    e       Rugged Joystick   A rugged joystick  PT DCJ  is available for direct  control of the PTU with no computer required   The PT DCJ provides proportional joystick con   trol and other inputs via a 25    connection  cable   Please see the PT DCJ Datasheet for  details      RS 485       Part Number  PT DCJ  joystick   PT DCJ CABLE  cable  required     Accessories    The following accessories may be
7. tors  Use this to make custom PTU  and or payload cables     Part Number  PTU CAB1 19PMILC  19 pin       Note  Each PTU with a wiring option  PLO1  PLO2  or  B PL17  includes one  1  19 pin mating connector  PTU   CAB1 19PMILC         RS 485 to RS 232 Converter    Bi directional module that converts signals from RS 232 to RS   485  Includes power supply  coupler  and cable     Part Number  PTU CONV RS485C    USB to RS 485 Adapter Cable    Cable that converts USB to RS 485 serial connections     Part Number  PTU CONV USB RS485    Rugged Joystick and Cable  This rugged joystick allows PTU control without a host com   puter  Cable ordered separately     Part Number  PT DCJ  joystick  and  PT DCJ CABLE  25    DCJ connection cable        Page 6 of 7  890C Cowan Road  Burlingame  CA 94010 e Office  650 692 3900 e Fax  650 692 3900   e MCS flir com    www flir com MCS  03 2013    PTU D47 Series Configuration Guide    Geo Pointing Module and Ethernet Web    Interface    The Geo Pointing Module  DGPM  provides both an Ethernet   web interface for PTU control and geo pointing capalities   Please see the following documents for additional information     e Geo Pointing Module Datasheet  e Geo Pointing Module User   s Manual    Part Number  PTU DGPM       Extension Cables  An extension cable extends the length of a breakout cable     There is a male connector on one end and a female connector  on the other  Available in 50    and 100    lengths     Part Number  PTU CAB EXT 50  50     or 
    