Home
SolarNAPL TR
Contents
1. 19 Pressure switch cover remove nut and cover to adjust Air solenoid valve Turn the nut clockwise to increase the pressure that the com pressor will shut off at NEVER EXCEED 100 PSI The pressure that the tank will drop to before the compressor will restart is 15 to 20 psi below the shut off pressure Pressure switch without cover 20 Solar panel controller SOLAR CHARGE CONTROLLER TEMP SENSOR Always leave the battery type set to 1 The battery status gives the operator a general idea of the charge status of the battery The display changes from battery volts to solar amps the amps the solar panel is collecting To convert to watts multiply by 12 then to load amps You will normally see no load amps displayed unless the compressor is running because the controls are drawing only a few watts The LED s to the right of the display indicate the value being displayed Push button switch that will turn off the load function of the solar panel controller This will turn off the compres sor and all controls Timing delay relay The logic for the controls are as follows When the pressure in the tank is low enough the pressure switch will close The air com pressor will then start running to refill the tank At the same time the air solenoid valve will shut the air supply off to the recovery pumps The air supply will then remain off for the duration that was set on the relay Wh
2. The sensor has a 2 inch male pipe thread Connect the quick connect cable connector to the control box If the optional water sensor shut off has been purchased screw the 2 inch PVC bushing into the tank and slip the tank overfill water sensor into the bushing To adjust the water sensor open the sensor s enclosure by removing the two screws then loosen the cable strain relief on the water sensor s cable Lower the water sensor until it hits the tanks bottom then pull the sensor up a few inches and tighten the sensor strain relief Reinstall the enclosure s cover and tighten both screws See attached photo s for more detail Once this is completed open the control box and familiarize yourself with each of the components Your will note that power should now be on at the Solar Controller and the compressor may be running After the SolarREM unit is mounted and electrically connected check that the solar controller is signaling a battery charge and the solar panel is charging the battery If this is the case you are ready for the initial setup of the oper ating parameters Refer to the next detailed section for installation and operating procedures da Frequently Asked Questions Q Why don t I get a display after connect the wiring A Q A Check for cross connections with the wiring If you have inadvertently connected either the battery or the solar panel to the wrong leads you will not get a signal on the solar co
3. solar panel open the junction box under the solar panel by loosening the four screws located on the cover Red positive Black negative CAUTION Solar panel WILL GENERATE POWER when in contact with a light source ra tol a E w En Electrical junction box back of solar panel 10 Loosen the watertight strain relief and insert the 10 2 cord through and tighten Connect the 2 wires to their proper poles 10 2 cord 15 ft supplied water tight strain relief 11 Close enclosure with 4 attached screws Green Red neg pos 15 12 The tank full sensor has a 2 inch male pipe thread bushing Thread the bushing into the tank top If your tank has a larger pipe thread opening you will need to obtain the proper reducer not supplied by DGSI Caution If the tank is not level make sure you install the tank full sensor on the lowest end of the tank 13 Optional dual sensor tank full and water sensor Cord strain relief 30 ft cable standard Longer lengths available Water resistant n Ba enclosure 2 inch pipe bushing Tank full float Quick connect to Water Teflon control panel sensor coated NOTE Most units probe cable will be prewired into the control box 13 To install the dual tank sensor thread the 2 inch plastic bushing into the tank opening If the tank used has a larger pipe opening you will need to obtai
4. 0 steel pole mounted a minimum of three feet into the ground with a concrete base of a least one foot around The pole should extend about seven feet high to allow for clearance of the solar panel from the box Electrical Wiring Once the SolarREM unit solar panel s and battery have been installed as per the installation configuration all com ponents must be electrically connected and grounded WARNING To avoid possible injury or death due to electrical shock carefully examine the wiring and connect to the appropriate battery and solar panel lead The solar controller will prevent cross connections from damaging the solarREM unit CAUTION Use only copper conductors for field installed electrical wiring All field installed wiring including electrical ground must comply with the National Electrical Code NEC as well as all applicable local codes In addition all field wiring must conform to Class II temperature limitations described in the NEC Consult the unit wiring diagram located on the inside of the compressor access panel to ensure proper electrical hookup Once the SolarREM unit is mounted connect the wires that are labeled for the battery and for the solar panel from the bottom of the control box BLACK is for positive and WHITE is for negative Connect each of the wires to the ap propriate terminals on the battery and solar panel ensuring a tight connection is made Place the tank full float sensor into the product storage tank
5. SolarNAPL TR 51600 Installation Operation and Maintenance Guide SolarREM Solar Powered Remediation Technologies The first truly environmental remediation product Version 2 1 DURHAM GEO SLOPE INDICATOR Table of Contents Chapter 1 Installation Operation and Maintenance cc sescesseeees 1 vs 8 6 672 ON ie E E E eee 2 Tecnnica UDN een E cee mene are cr 3 Chapter 2 About the SolarRemM oannnnnnnnannnnnnnsnnnnnnnnnnnnnnrnnnrrnnrrennrennrrnnni 4 Chapter 3 About the COMP ONC MES cee rscececececsnneiteteeceneaiecacesanwnraaneceecs lt hene 5 Chapter 4 oalely WATOMANATOMN essaies ESEA EEr nena 6 Chapter 5 Installation Instructions vier gececcnedigeepentesees octiecaieteriesinounceacesdcaaes 7 FS oe western dd pier r E A higtbanunonenisinesen 8 Chapter 6 12116 6 gk 0 e112 g cane eee ee eee eee ee 10 Chapter 7 System Configuration Operation cccccccsseeesseeeeeseeeeees 23 Chapter 8 TOUDE OC UNG arero e A E EE E 24 Chapter 9 Additional Components a secresin degcaeeineactnaseadcoaasertunecstetenecuedaenies 26 Chapter 1 Installation Operation and Maintenance Guide Introduction solarREM The First Truly Environmental Remediation Product About the SolarRem Product Family SolarREM identifies the three provided for assistance in bioremediation of contaminated sites remote from an economical power supply not quickly accessible and subject to long term rem
6. air compressor will not run Probable Cause Cr Oia I Co 1 2 3 The solar controller has shut off power to the controls and compressor The battery is dead and cannot be charged The fuse in fuse holder 56 is blown The compressor has failed The pressure switch has failed The solar controller has failed rrective Action Increase the delay time to allow the solar panel to fully charge the battery Increase the size or number of solar panels and or batteries Remove the battery and recharge with a 110 Volt AC charge and load test Voltage is not a fool proof way of testing the amp hour charge in a battery only load testing is This can be performed at most auto parts stores or can be done with an inexpensive 100 amp load tester 4 Replace the fuse If the system continues to blow fuses look for any loose wires 5 Replace any failed components All of the components can be easily removed from the aluminum backing plate by unscrewing the fasteners The backing plate does not need to be removed from the enclosure to gain access to any of the components 6 Replace the pressure switch or dress the contacts with a points file that can be purchased at most auto parts retailers 7 Replace the solar controller Symptom The sensor relay power LED is off Probable Cause 1 2 3 The fuse to the relay is blown The sensor relay has failed Loose wire connection s Corrective Action E 2 3 24 Chec
7. as recharged the battery The systems operational logic and how it operates is as follows When the pressure in the air tank falls to the pressure switches low setting factory set to approximately 75 psi the pressure switch closes and the compressor will refill the air tank to the factory setting of approximately 95 psi Note Never adjust the pressure switch above 100 psi Setting it above 100 psi will damage the air compressor When the pressure switch closes and starts the compressor it also starts the delay timer The delay timer shuts off the air supply to the air out until the timer times out The factory setting for this function is 63 minutes Note Do not decrease the delay time to less than 15 minutes Note A filter regulator provided must be used between the controller and pump If no back pressure is present when the controller begins to supply air to the pump the unit will discontinue the supply phase and begin the delay phase Note At initial start up back off filter regularator pressure to zerio psi After supply cycle begins increase air to pump to desired pressure After the delay time the air solenoid valve will open supplying compressed air to the air out connection This cycle is repeated 24 hours per day unless one of the following occurs 1 The solar controller shuts off power to the controls and compressor because the solar panel cannot produce enough power to keep the battery charged To alleviate this pr
8. aximize the off cycle to the conditions of the site The battery and solar panel are sized to maximize operating time providing up to 2 days operations during peri ods with minimal sunlight heavy rain The solar panel ensures quick recharge to get the battery back into opera tion as the result of a long low sunlight period A 7 5 gallon ASME air receiver tank is standard to provide optimum compressor pump operation and minimize on off cycles that result in large battery draw Technical Support Information presented in this publication has been carefully checked for reliability However no responsibility is assumed for inaccuracies The information contained in this document is subject to change without notice lf a problem arises with your system you should turn to your dealer or the manufacturer for help first Your sys tem has most likely been configured by them and they should have the best idea of what your system contains Hence they should be of the most assistance Further if you purchased your system from a dealer near you you can bring your system in to them to have it serviced instead of attempting to do so yourself which can have expensive consequences Our web page www durhamgeo com Technical support phone line 800 837 0864 Durham Geo Slope Indicator 2175 West Park CT Stone Mountain Ga 30087 Returning Merchandise for Service During the warranty period contact your distributor or system vendor FIRST for an
9. e mounting kit 6 Mount the control box pole struts as shown Back view of control box mounted to 3 inch schedule 40 pipe Front view of control box mounted to 3 inch schedule 40 pipe Hardware kit for 3 inch tank pole mount Pressure gauge relief valve and air connect fitting to control panel Manual water drain 12 Back view of tank mounting hardware attached to 3 inch pipe If the tank is not pole mounted orient it as shown so the manual condensate drain will function properly Battery box pole mounting hardware kit for 3 inch schedule 40 pipe Sideview of control box and battery box pole mounting hardware 13 Mounted battery box with battery installed Bottom view of control panel 7 Run the 10 2 S O cord from the bottom of the control box through the water tight strain relief located on the bottom of the battery box Connect these to the plus and minus terminals to the battery then tighten the strain relief on the cable Excess cable can be stored in the battery box 8 Connect the 3 8 inch Buna N hose from the control box to the Pressure gauge air tank 14 Shut off valve Make sure this is fully open Pressure relief valve Hose barb to tank Hose clamp 3 8 Buna N hose from control box Front view of air line connection to tank 9 To connect the control box to the
10. ediation requirements 1 The SolarNAPL provides pneumatic pumping capabilities for removal of LNAPL contaminants laying on the ground waiter table It is provided with a storage tank level sensor to shut the system down when full to prevent a surface spill 2 The SolarPurge provides pneumatic pumping capabilities for low flow groundwater pumping 3 The SolarSPARGE provides higher air flow into the ground water table to promote bioremediation and volatilization of LNAPL contaminants in the groundwater Upon receipt of shipment at the job site carefully check the shipment against the bill of lading Make sure all units have been received Inspect the carton or crating of each unit and inspect each unit for damage Repackage unit after verifying that all components are included Assure that the carrier makes proper notation of any shortages or damage on all copies of the freight bill and that he completes a Carrier Inspection Report Concealed damage not discovered during unloading must be reported to the carrier within 15 days of receipt of shipment NOTE It is the responsibility of the purchaser to file all necessary claims with the carrier Notify DGSI of all damage within fifteen 15 days of shipment Unit Protection Cover units on the job site with either shipping cartons vinyl film or an equivalent protective covering Cap the open ends of pipes stored on the job site In areas where painting plastering or the spraying of fireproof mate
11. en the duration has ended the air solenoid valve will open allowing air to be delivered to the recovery pumps The delay time will allow the solar panel time to recharge the bat tery and will also allow for 24 hour operation of the pump DGSI suggests that you start with a 60 minute delay and see if you are recovering the amount of product that is recharging the well Give this initial delay several days of testing prior to adjusting Only then should it be reduced DGSI recommends never to set the delay to less than 15 minutes NOTE Do not change A B C or D dip switches When these dip switches are moved to the right they add up to the sum of the delay off time In the image the delay is set to 63 minutes 2d Status Lights Will be on when water Power LED should is in the tank always be on Tank float indicator LED Conductivity LED When When on float is down On water has been detected Off when tank is full in tank 22 Chapter 7 System Configuration Operational Logic The solar panel generates electricity which is regulated by the solar controller The solar controller monitors and charges the 12 Volt AGM battery The solar controller will shut off the electrical power to the compressor and con trols if the battery s voltage stored electrical energy drops too low Electrical power will only be restored to the systems controls and air compressor when the solar panel thru the solar controller h
12. essor and pump and associated wiring and controls The solar panel charges the battery which serves as the power supply for the air compressor and the system controls When activated the compressed air is discharged to the pneumatic pump forcing the product up the pump dis charge hose and into a holding tank The operating characteristics and performance of the SolarNAPL is deter mined in part by the specifications of the solar panel battery and pump Operating parameters such as the reset time no air to pumps is adjusted with the electronic timer To operate correctly and efficiently air must be pumped into the pneumatic pump at a pressure sufficient to dis place the water column and overcome frictional losses in the system The injected air displaces the product col lected in the pump and discharges it to the collection system This air and product cycling continues in the pump while the air is available Technical Description Overview The power supply for SolarNAPL consists of a photo voltaic array and battery The photovoltaic cells use sunlight to charge the battery The battery in turn powers the system controls and the air compressor pump The pump fills an air receiver tank that provides the pressure and volume of air required to displace the product in the pneu matic pump A voltage regulator is used to prevent the battery from overcharging The voltage regulator also prevents draining of the battery when there is not en
13. henever working around any electrical equipment care must be taken to avoid shock or worse injury The solar panel cells are encapsulated between a tempered glass cover and an EVA pottant with PVF back sheet to provide maximum protection from the most severe environmental conditions The entire laminate is installed in an anodized aluminum frame to provide structural strength and ease of installation Chapter 5 Installation Instructions What s the first thing should do The first thing you should do is read this user s manual It contains important information which will make configura tion and setup much easier The following depicts an installation of a solar system being mounted on a 3 inch schedule 40 steel pipe that has been grouted to the earth In some instances this type of installation may not be practical or desired however in all installations the electrical and pneumatic components must be interconnected as shown in the following instructions If there are longer distances than the supplied wiring may allow between the control panel and the battery or solar panel the wire size and splicing will need to be adjusted as required The wiring diagram and parts list for the unit can be found in the document holder inside the front cover of the con trol box and on the DGSI web site Pole Installation and Mounting Properly attach the SolarREM unit and equipment to a secure mounting pole We recommend a three inch Sched ule 4
14. ime is the sum of the numbers that have been pushed to the right The max off time is 60 minutes Do not shift any of the dip switches above the numbered dip switch 3 Solenoid Valve The solenoid valve is the open close control point for air supply to the well point The solenoid valve is controlled by the timer and is placed in line after the air receiver tank 4 Pressure Switches The high pressure switch shall have a range of 80 100 psi and be equipped with a dual manual lever automatic off The low pressure unit shall have a range of 0 to 40 psi and operate on an automatic setting The pressure switches shall be supplied by Pumptrol Grainger or the equivalent 5 Air Compressor Pump The air compressor shall be one of two options depending on site conditions or user specifications A Thomas diaphragm compressor model 405ADC 38 12 rated at 124 cfm at 100 psi or a Thomas model 910CDC22 rated at 148 cfm at 40 psi 6 Piping All internal piping shall be high pressure flexible hosing with schedule 40 brass pipe fittings and hose barbs All fittings shall be wrapped with Teflon tape to minimize air loss Chapter 4 General Safety Information The SolarREM Equipment is designed to be safe when handled correctly It is important that all site safety proce dures be followed including all Occupational Heath and Safety Administration OSHA site requirements national electric codes and all applicable state and local regulations W
15. k fuse holder 54 for a blown fuse and replace if necessary Replace the sensor relay if 12 Volt power is verified between terminals 1 and 2 and the relay LED is off Look for loose wiring connections if the fuse is not blown and there is no power between the sensor relays and terminals 1 and 2 System Troubleshooting Cont Symptom The air tank is full at high pressure but air is not exiting from the air out port fitting Probable Cause oo le o I a Co 1 o N Oo SY The solenoid and or solenoid valve is bad The air valve is shut on the tank The delay timer has failed Relay 61 or 62 has failed The product storage tank is full The optional conductivity probe has detected water The tank sensor relay has failed Loose wire connection s rrective Action Verify that 12 Volts is being received at the solenoid If it is then remove the solenoid valve disassemble and clean the internal components Reassemble and reinstall If still not functioning properly replace Open the air valve on the tank Replace the delay timer Replace the 61 and 62 relays Empty the product storage tank Remove the water or raise the conductivity probe Replace the tank sensor relay Check for loose wiring Consult the wiring diagram for details 25 Chapter 9 Recommended Components DGSI recommends the following skimming systems to use in conjunction with the SolarNAPL system DGSI manufactures two pneumatica
16. lding gasoline recovery projects where evaporation of the recovered product may exceed that of recovered product lf for some reason the P O D skimmer cannot be used in a particular well i e not enough well depth below the product water interface then the recommended skimmer is the FAP with the adjustable timer The FAP pump cycles to pump the product to the product storage tank regardless of the product level in the well By using the FAP adjustable timer the cycling time can be reduced from 10 12 cycles per minute standard FAP to a cycling time as slow as 1 cycle every 2 minutes This reduction in the cycle rate allows the free product to enter the well and increases the possibility that each dumping cycle would be full of product A disadvantage of using the FAP skimmer with the SolarNAPL is that the minimum air pressure to operate the pump is 60 psi This pressure would lift free product to over 120 vertical feet and will consume more volume of com pressed air than needed in any well that is less than 120 feet deep The FAP pump also requires the use of a coalescing filter regulator to remove moisture from the air supply because the on off cycle timer uses air logic 26
17. lly powered skimming systems the FAP and the P O D Pump On Demand Both can be used with the DGSI SolarNAPL however the P O D is first recommended for use with the SolarNAPL for the following reasons 1 Unlike the FAP the P O D skimming system only uses the stored compressed air when it has collected a volume of the skimmed free product 2 When the supply of compressed air has been shut off by the SolarNAPL s delay timer the P O D pump con tinues to collect free product until it is completely full When the delay timer is timed out and the air supply is returned to the P O D pump it will immediately pump the recovered productthat is stored in the pump to the product storage tank 3 Another important feature of the P O D pump that compliments its use with the SolarNAPL is that it can operate at pressures as low as 10 psi By supplying just enough air pressure to lift the product out of the recovery well and into the product storage tank the operator maximizes the stored energy of the compressed air that was produced by the SolarNAPL system This results in more product recovery and less run time for the compres sor additionally increasing the life expectancy of the air compressor 4 The P O D pump can accept wet liquid water in the air supply without damaging the pump 5 The P O D comes standard with a cycle counter that counts the pump cycle and thus indirectly the volume of recovered product This is important on slow yie
18. n the correct reducing fittings not supplied by DGSI 16 14 Carefully insert the conductivity probe into the 2 inch PVC bushing 15 Next insert the high level float sensor into the 2 inch pipe bushing followed by rest of the sensor assembly 16 Remove the top cover of the sensor as sembly by removing the 2 screws Loosen the conductivity sensor cable strain relief seal and lower the probe until it makes contact with the tank bottom Raise the probe 2 to 3 inches and tighten the strain relief ll 17 Reinstall the cover on the dual sensor and tighten the two screws For added safety DGSI reccommends that a silicon type sealant be ap plied to the top of both screws 18 Connect the tank full or dual tank sensor to the control box using the quick connect twist to connect if the unit was supplied with one 19 Attach the earth ground to the 3 inch sched ule 40 pole or a properly installed grounding rod NOTE This is mandatory for the proper function of the sensor relay Close up of earth ground lug 18 Control box components and function NOTE All components can be removed from the enclo sure by unscrewing them from the back plate There are no hidden fasteners located behind the mounting plate Front of control panel Pressure switch Air compressor Air solenoid valve Solar controller 15 amp max input Fuses Timer Relays Sensor relay
19. nclosure The lockable weatherproof enclosure is designed to house and protect all equipment The fiberglass NEMA 4 enclosure provides weather protection as well as vandalism protection of less durable equipment Dimensions are 19 6 inches high by 17 6 inches wide by 8 8 inches deep with a front opening locking panel 4 Air Receiver Tank The air receiver tank equalizes air flow and eliminates pulsing of flow from the air compressor to the well point The air receiver tank is a 7 5 gallon tank ASME rated tank optional 5 Battery Enclosure The lockable battery enclosure is designed to secure the 12 Volt battery and is constructed of heavy gauge welded aluminum All hardware is stainless steel and can be mounted on a 3 inch pipe pole using an optional hardware kit Internal Components 1 Photovoltaic Charge Controller Also known as a charge regulator this part of the system provides safe charging of the battery by the solar panel and regulates the charge flow to maximize the operat ing life of the battery The charge regulator also prevents discharge of the battery back through the solar panel during periods of no sunlight The charge regulator shall be a Prostar 30 manu factured by Morningstar Corporation 2 Time Delay Relay The time delay relay air off timer is adjusted by moving the numbered dip switch es to the right The air solenoid valve will be closed and air will not go out of the tank until the timer has timed out The delay t
20. ntroller If the wiring is crossed the same will apply you will not get a signal Why don t get an indication the solar panel is charging the battery First check the solar panel is connected to the solar controller and with the correct polarity Second check the solar panel is pointed at the correct angle and location to receive the maximum sunlight during the day What is a solar cell A solar cell is a kind of semiconductor device that takes advantage of the photo voltaic effect in which electricity is produced when the semiconductor s PN junction is irradiated When light strikes a solar cell part of it is reflected part of it is absorbed and part of it passes through the cell The absorbed light excites the bound electrons into a higher energy state making them free electrons These free electrons move about in all directions within the crystal leaving holes where the electrons used to be and the holes also shift around the crystal The electrons collect in the N layer the holes in the P layer When the outside circuit is closed electricity flows Front electrode Anti reflection coating EN N type silicon P P type silicon B Back electrode Frequently Asked Questions Cont Q What about grounding of the SolarREM unit A The SolarREM unit is to be grounded to the mounting pole with the provided ground wire Equipment acts as a conductor due to voltage between the ground
21. oblem one or more of the following steps may need to be be performed e Increase the delay time to give the solar panel enough time to charge the battery e Increase the size of the solar panel Note the systems solar controller is rated at 15 amps or 180 watts If a solar panel rated at more than 180 watts is required consult the manufacturer for advice e Increase the number or size of the batteries Note The battery may need to be replaced and a weak battery can cause a system shut down 2 The product storage tank is full or the cable to the tank sensor has been cut e When the product tank is full the A LED on the sensor relay will be off the power LED will be on and relay 62 will be on e If the cable is cut the status of the LED s listed above will be the same however the tank will not be full enough to lift the tank full float 3 Water has been detected by the optional tank conductivity probe e When water has been detected the B LED and the Power LED will be on Either remove the water from the tank or remove the sensor from the water to re start the system Note The product recovery operator will need to determine which skimming system is pumping water and adjust its height or check it for damage that could result in water being pumped e Ifthe cable to the conductivity probe is cut it will not shut off the air supply to the skimmer pumps 23 Chapter 8 System Troubleshooting Symptom The
22. ough sunlight e g at night to sustain flow of electricity from the solar panel to the battery The SolarNAPL is operated by an adjustable air off timer After an on site pilot test to determine optimum operat ing conditions including injection pressure and air flow rate the air off time is optimized When the system is activated the compressor pump pressurizes the air receiver tank When the pressure inside the tank drops below the lower set value the pump turns on to re pressurize the tank until the air pressure reach es the high set value When the pump starts running the air supply to the pump s are shut off for the amount of time the operator has set on the adjustable electronic timer up to 60 min Chapter 3 About the Components External Components 1 Solar Panel The solar panel is capable of producing a minimum of 16 to 20 amp hours per day at 75 percent sunlight for a minimum of six hours A minimum configuration is a 60 Watt panel with larger panels used as necessary for particular sites or applications 2 Battery The battery supplies 12 volt DC power to the unit It is capable of providing back up power for up to two days for a typical SolarREM installation The battery is an industrial 12 volt deep cycle battery designed for use with solar panels The minimum size provides 120 amp hours The battery is an absorbed glass mat AGM construction We do not recommend use of typical lead acid batteries 3 Weatherproof E
23. rial has not been completed all due precautions must be taken to avoid physical damage to the units and contami nation by foreign material Physical damage and contamination may prevent proper start up and may result in costly equipment clean up Examine all pipes fittings and valves before installing any of the system components Remove any dirt found on these components Storage CAUTION Do not store or install units in corrosive environments Corrosive conditions and high temperature or humidity can significantly reduce performance reliability and service life Upon the arrival of equipment at the job site immediately store solar panel units in their shipping cartons in a clean dry area Store units in an upright position at all times Specifications The SolarREM units are designed to provide operating capabilities in remote locations away from the power grid and to be operated in a simple fashion both in setup and in operating mode The units are designed for a no shock or explosion hazard environment A deep cycle battery is provided to withstand the rigors of weather and deep power draw The solar panel pro vides recharge of the battery to permit a longer operating period of the units A low draw DC powered compressor pump provides the necessary compressed air for all configurations The standard base model as supplied by SolarREM is designed to provide a sturdy low maintenance air compres sor providing adjustable timing to m
24. s Bad Lightning Strike Inverter Battery Bank Generator Ground mar Ground Eatery Ground m e pa ie utd vk Dl terence ks Het 2 Figure 1 HMultiple Point Ground System Equipment all grounded at same point no voltage across a system no current flow through equipment and wintg Lightning Strike Inverter Battery Bank Generator Ground aa ls Eatery Ground tero Voltage difference across component grounds Figure 2 Single Point Ground System Chapter 6 Initial Setup of the SolarNAPL Introduction to Setup 1 Be careful unpacking the solar panel Make sure no damage oc cured to the shipment 100 watt solar panel 2 The solar panel can be mounted to small or large diameter poles but the user will need to supply their own Ta clamps g by s Pole mounting hardware for 180 watt TEETE panel to 3 inch pipe Son 3 inch pole mount hardware kit shown installed 3 Tighten the U bolt Notice that the steel plate is on the inside of the aluminum channel Tighten the 2 hose clamps 10 4 After concreting the 3 inch pipe into the ground mount the solar panel to the pole and adjust to the direction that will provide the most sunlight The National Renewable Energy Laboratory NREL is a good resource to use for positioning the solar panel in the USA www nrel gov pv 5 Tilt the panel to achieve maximum output Control box pol
25. y product problems This war ranty only covers normal customer use and does not cover damages incurred during shipping or failure due to the alteration misuse abuse or improper maintenance of products For Resellers Only A receipt or copy of your invoice marked with the date of purchase is required before any warranty service can be rendered You can obtain service by calling the manufacturer for a Return Merchandise Authorization RMA number The RMA number should be prominently displayed on the outside of the shipping carton and the package should be mailed prepaid or hand carried to the manufacturer SolarREM will pay to have the unit shipped back to you Disclaimer Information presented in this publication has been carefully checked for reliability However no responsibility is assumed for inaccuracies The information contained in this document is subject to change without notice Chapter 2 About the SolarREM The SolarREM is a solar powered remediation unit capable of either free product recovery system SolarNAPL SolarPURGE SolarSKIM fluid injection SolarDRIP or pressurized air SolarVent SolarSPARGE The unit is capable of running up to 2 days without sunlight By relying on solar power SolarNAPL can be installed in any location where a power supply necessary to run traditional pumping systems is not economically available SolarNAPL is a self contained remediation system consisting of a solar panel battery air compr
Download Pdf Manuals
Related Search
Related Contents
F DE GB ITA Elektrobike ED-3.2 EX そ の 美 し い 画 像 が 画 像 が、デ ザ イン が、 ビジ ネ スを 快 適 取扱説明書[BK-4HCC/4,/2] (973.27 KB/PDF) R V R Ede - Maison du Platin Expanding Grain Model [EGM v1.0] - Illinois Institute of Technology Systèmes de référence en pratique - Swisstopo 三菱重工業株式会社 名古屋航空宇宙システム製作所 E7632765H50 丶 十 へ 〇ご使用前に、 この取扱説明書を必ずお読み Copyright © All rights reserved.