1. 07 2015 Rev 3
2. Installation and user handbook Pulse out module i N N UW Hikkema Installation user and maintenance manual Pulse out module All rights reserved Copyright O 2015 Wigersma amp Sikkema B V NL 6980 AC Doesburg All the figures and descriptions in this installation operating and maintenance manual have been compiled only after careful checking Despite this however the possibility of errors cannot be completely eliminated Therefore no guarantee can be given for completeness or for the content Also the manual cannot be taken as giving assurance with regard to product characteristics Furthermore characteristics are also described that are only available as options The right is reserved to make changes in the course of technical development We would be very grateful for suggestions for improvement and notification of any errors etc With regard to extended product liability the data and material characteristics given should only be taken as guide values and must always be individually checked and corrected where applicable This particularly applies where safety aspects must be taken into account Further support can be obtained from the branch or representative responsible for your area The address is printed on the back of this manual or simply enquire at Wigersma amp Sikkema B V Passing this manual to third parties and its duplication in full or in part are only allowed with written permiss
3. SD is caused by static electricity and the damage caused is usually permanent Inside the device in which the pulse out module is to be placed there are parts that are connected with the main power supply Disconnect the ear mains power supply temporarily during any work See the user handbook for the device in which the pulse out module is to be placed Depending on the device in which the pulse out module shall be place the pulse out module must be installed as follows e All models UNILOG 300 with mains supply of type N33 N34 or N35 see type plate left exterior there are 1 or 2 open connections on the first PCB Place the pulse out module on an open connection e SC230B see type plate left exterior there are 3 connections Other modules may be present Place the pulse out module on an open connection 2 2 Connection with external devices The wiring for connecting with external devices is fed through a free cable gland from the UNILOG 300 or ISC230B and connected to one or more screw connectors to the outputs OUT 1 to OUT 4 of the pulse out module There are no specific demands for the wiring except that it is suitable for a watertight led trough by the cable gland The possible polarity of the connection with the external devices does not need to be taken into account Maximum values of the signal of the external devices 125 V direct or alternating current 100 mA DDNN102GHGB 07 2015 Rev 3 3 Installation us
4. an unlimited operational lifetime The pulse outputs can switch both direct current and alternating current All 4 outputs are also galvanically isolated from each other With jumper settings the pulse outputs can be coupled to two external pulse contacts or the two internal pulse outputs of UNILOG 300 It is also possible to arrange several pulse outputs parallel so that the same pulse can be sent galvanically isolated to multiple systems All signals are provided with indicators so that the function and configuration can be easily and rapidly checked Order number NN2671 lt 125 V AC or DC ve p Jumper field P Cy sl ENT SZ v Pulse output y men SE me 1 PER S LEZ EE E OUT 1 Jumper set INT 1 OUT 1 to INT 1 Ped ae pE br Pulse output y OT vg ae n OUT 2 EXT 1 Jumper set OUT 3 to OUT 2 Go NGS ZY NA Pulse output ESKE AN ES a e AN OUT 3 INT 2 Jumper set A NVH OUT 2tooff Z7 Pulse output og Se AA aD of Oo OUT 4 EXT 2 Figure 1 Schematic representation of functions for the pulse out module DDNN102GHGB 07 2015 Rev 3 2 Installation user and maintenance manual Pulse out module 2 Installation 2 1 Placing the module Electrostatic discharges ESD can cause damage to internal electrical Zz ESD components if you do not take preventative measures E
5. bled with the pulse signal EXT2 The functioning of the jumper setting is easy to check when indicator EXT1 lights up also led indicator OUT2 lights up Jumper in on position 1 4VP Puls Out If multiple pulse outputs are needed for the same pulse signal then a horizontally placed jumper in the top position can forward the pulse signal through to a second pulse output See for example below whereby an extra connection is made for the pulse signal EXT1 also using the pulse output OUT 1 2 pulse outputs for same pulse signal 19 4VP Puls Out DDNN102GHGB 07 2015 Rev 3 5 Installation user and maintenance manual Pulse out module 4 Maintenance The pulse out module does not need maintenance For maintenance of the devices in which the module is placed refer to the user manual of the devices in question 5 Technical specification e Pulse outputs 4 optical solid state output independent galvanically isolated e Max contact signal 125 V AC and 100 m ett e On resistance lt 30 Q e EMC Protection 400 W transient suppression e Max output frequency 100 Hz DC 50 e Operating temperature 25 C to 55 C DDNN102GHGB 07 2015 Rev 3 6 wig ersma Sikkem Wigersma amp Sikkema B V Postbox 109 6980 AC Doesburg Leigraafseweg 4 6983 BP Doesburg TEL 31 0 313 47 19 98 FAX 31 0 313 47 32 90 info wigersma sikkema com www wigersma sikkema com DDNN102GHGB
6. d to the pulse inputs IN1 and IN2 of the UNILOG 300 screw terminals 3 to 6 A pulse signal at input IN1 shall emit an EXT1 pulse signal and a pulse signal at input IN2 shall emit an EXT2 pulse signal This is easy to follow through for example shorting the IN1 screw terminal of the UNILOG 300 with a wire will light up the led indicator EXT1 The same applies for the IN2 input and the EXT2 led indicator o The two internal pulse outputs of the UNILOG 300 A pulse signal from pulse output 1 of UNILOG 300 shall emit an INT1 pulse signal and a pulse signal from pulse output 2 of UNILOG 300 shall emit an INT2 This is clearly visible by means of the led indicators INT1 and INT2 DDNN102GHGB 07 2015 Rev 3 4 Installation user and maintenance manual Pulse out module Consequently the pulse signals INT1 EXT1 INT2 and EXT2 can be coupled with a jumper to the corresponding pulse outputs OUT1 OUT2 OUT3 and OUT4 With a jumper in top position no coupling is present the pulse output is disabled see below for example in which all pulse outputs are disabled This is the standard factory setting OUT OUT2 OUT3 OUT4 Jumpers in off position E i INTL JEXT1 OINT2 JEXT2 1 4VP Puls Out With a jumper in in the lowest position the pulse output is coupled and active see for example the illustration below whereby the pulse output OUT2 is enabled and with the pulse signal EXT1 and the pulse output OUT4 is ena
7. er and maintenance manual Pulse out module 3 Settings and indicators a ao aoe on F EOSIN SN 2 a a C J C Y D AN QM F O e k e e Da 5 D D O O O O mm H sergas 3 4 5 6 2 8 eq INT1 EXT1 INT2 C JEXT2 OUTS MP ee ee D N OUTS 1 4VP Puls Out si Figure 2 Jumpers and led indicators Screw terminals of the 4 pulse outputs OUT 1 to and including OUT 4 Led indicators for the function of the 4 pulse outputs OUT 1 to and including OUT 4 Jumper field for coupling a pulse output to an internal or external pulse signal Be s DR Led indicators for the function of an internal or external pulse signal Calibrating the jumpers The pulse outputs on the pulse out module are coupled by means of jumper settings to an internal or external pulse signal When the pulse out module is placed in an ISC230B o The two external pulse signals that are connected to the pulse inputs IN1 and IN2 of the ISC230B screw terminals 3 to 6 pulse signal at input IN1 shall emit an EXT1 pulse signal and a pulse signal at input IN2 shall emit an EXT2 pulse signal This is easy to follow through for example shorting the IN1 screw terminal of the ISC230B with a wire will light up the led indicator EXT 1 The same applies for the IN2 input and the EXT2 led indicator When the pulse out module is placed in a UNILOG 300 o The two external pulse signals that are connecte
8. ion from Wigersma amp Sikkema B V The guarantee becomes invalid if the product described here is not handled properly repaired or modified by unauthorized persons or if replacement parts are used which are not genuine parts from Wigersma amp Sikkema B V Preface E This handbook provides important information Read this handbook carefully E In this handbook various notes and warnings are marked with symbols Read them carefully and take any measures necessary The symbols used have the following meanings NOTE Suggestions and advice to make it easier to complete tasks AN ATTENTION A note that draws the user s attention to possible problems WARNING If the action is not correctly completed data or settings can be lost A note that draws the user s attention to measures that must be taken F e g for electrostatic discharge DDNN102GHGB 07 2015 Rev 3 1 Installation user and maintenance manual Pulse out module Table of Contents Preac uansssaale ee 1 MOUM 2 2 MSI NRS 2 1 Placing ING Modul Ne 3 2 2 Connection With External GEViC CS ud sccccehscconere tienes bd a a n a noua Reunnsesadeeabaiueialadien 3 3 Settings and INGICALONS iss smeden a Mantenan CO sa FEGNHICAl SPECMCAUON se O 1 Introduction The pulse out module is constructed with 4 configurable and galvanically isolated pulse outputs constructed with a solid state relay A solid state relay does not experience contact bounce and has in principle