1. PRO75A 100A MID Single phase two wire energy meter Ka User manual Version 1 21 DMMetering E Sartre WIN SUS Cl DAS stos 3 Z TO WO eer E oo oia 4 gt MID CENCI Eose a a a oss a res eine tee setae eam E enw a 5 A CEC NC perso ee ee E E E ee eee 6 3 P NaC e E e EEE E E E EE A 8 SEE e eee en acs E E E E E asa E E E E E E E E E E E E E 8 7 Ba COO CO OO AN 8 o DESCON aa A E E E eds 8 DO DIMENSIONS A E a a a aaa aai 9 LO M raO arso aaa E E E EE ER 10 LE ODEON PP a E UA 11 Pid COMSUIMPECM INGICAN OA narra 11 H Reverse Macaco ascii iaa 11 iS Reading Me Meter aa ness ser aeuaaouns 11 LLA PUISS OUTPUT ao aaa EA 11 12 TOM esno0O dana 12 ES TECHNICA SUPDO Erronea 14 DmmMeteringR 2011 2 4 PRO75A 100A MID User manual 0031 1 Safety instructions Information for your own safety This manual does not contain all of the safety measures for operation of this meter because special operating conditions local code requirements or local regulations may necessitate further measures However it does contain information which must be adhered to for your own personal safety and to avoid material damage This information is highlighted by a warning triangle with an exclamation mark or a lightning bolt depending on the degree of actual or potential danger Caution This means hazard of electric shock and failure to take the necessary safety precautions Warning This means that failure to observe the instruc
2. EN 50470 3 2006 Electricity metering equipment a c part 3 Particular requirements Static meters for active energy class indexes A B and C Valid until March 16 2019 The results are recorded in the following annex test report 2113897 QUA CAL 09 4006 KEMA Quality B V Amhem March 16 2009 hone ing J H M Overbeek ir P J J G Nabuurs Certification manager Managing Director Notified body number 0344 Integral publication of this certificate and adjoining reports is allowed KEMA Quality B V Utrechtseweg 310 6812 AR Arnhem P O Box 5185 6802 ED Arnhem The Netherlands T 31 26356 20 00 F 31 26 3 52 58 00 customer kema com www kema com Registered Arnhem 09085396 Experience you can trust DMMeteriag R 2011 5 PRO75A 100A MID User manual 0031 4 CE certificate inepro DMMetering R 2011 Inepro Metering BW Pondweg 7 2153 PK Nieuw Wennep declare under cur solo responsiblity that the products PROSA PROFSD PRO75D MODBUS Single phase DIN rail Watt Hour Meter fo which this dodlarabon relatos in comicemity with tha koking European harmonized and published standards al date of the dedarationc IEC EN 50470 Following tha peovesions of tha Directives E appicablo Mw 200422 EG E eee ee numbers 6335 10 wath Hothead Body number NieuweWennep 2010 June 11 Place and da o of uo 0 PRO75A 100A MID User manual 0031 Declaration of Conformity We Iinepro Meteri
3. an be installed and used after being tested and can be sealed afterwards The device can be installed on a 35mm DIN rail or onto a panel with screws The meter should be installed on a location where the meter can be read easily In case the meter is installed in an area with frequent surges for example due to thunderstorms welding machines inverters etc the meter is required to be protected with a Surge Protection Device The device should be sealed immediately after installing it in order to prevent tampering DMMetering Rf 2011 10 PRO75A 100A MID User manual 0031 e Connection of the wires should be done in accordance with the connection diagram as shown below L L H H 1 2 Phase line IN OUT 3 4 Neutral line IN OUT 11 Operation 11 1 Consumption indication There is a red LED on the front panel which displays the power consumption measured by the meter When power is consumed the LED will flash The faster the LED flashes the more power is consumed For this meter the LED will flash 1600 times impulses per kWh 11 2 Reverse indication There is a LED on the front panel indicating the reverse direction REV The LED will be on in case of the current is flowing in the reverse direction through the load connected to the meter 11 3 Reading the meter The meter is equipped with a 5 1 register Five integers are marked black color and one decimal is marked red The reading accuracy is 1 10 kWh 11 4 Pulse output The ener
4. aveform 10A 100A 0 4 Ib Imax 30Imax for 0 01s 50Hz and 60Hz 10 lt 2W 10VA 1600imp kWh 1600imp kWh 11 5 11 5 11 5 1 0 1 0 1 0 Security wire slot PRO75A 100A MID User manual 0031 Material Front panel PC flame resistant plastic Cover ABS flame resistant plastic Base ABS flame resistant plastic 59 5 C GS o aa O O O N o sy T O A E 76 9 Dimensions D Height 130 mm Height without protection cover 100 mm Width 76 mm Depth 65 mm Max diameter cable 8 mm Size of the connection clamps 10 x 8 mm Weight 0 2 Kg net DmmMeteringR 2011 9 PRO75A 100A MID User manual 0031 10 Installation A CAUTION Turn off and if possible lock all sources supplying the energy meter and the equipment that is connected to it before working on it Always use a properly rated voltage sensing device to confirm that power is Off WARNING The installation should be performed by qualified personnel familiar with applicable codes and regulations Use insulated tools to install the device A fuse thermal cut off or single pole circuit breaker should be fitted on the supply line and not on the neutral line The connecting wire connecting t
5. ent editions If you have any suggestions please do not hesitate to contact us Subject to technical modifications without notice Copyright Copyright Inepro Metering June 2011 All rights Reserved It is prohibited to pass on or copy this document or to use or disclose its contents without express permission of Inepro Metering BV Any duplication is a violation of the law and subject to criminal and civil penalties All rights reserved particularly for pending or approved patent awards or registered trademarks Registered trademarks DMMetering is a registered trademark of Inepro Metering BV member of the Inepro Group Other names appearing in this manual may be trademarks of third parties and are property of their respectful owners 2 Foreword Thank you for purchasing this energy meter Inepro has a wide product range of devices We have introduced a large number of energy meters on the market suitable for 110V AC to 400V AC 50 or 60Hz Besides the normal energy meters we also developed our own pre paid meters with chip card chip card re loaders and a complete PC management control system For more information on other products please contact our sales department at sales ineprometering com or visit our website at www ineprometering com Although we produce this device according to international standards and our quality inspection is very accurate it s still possible that this device shows a defect or failure for which we do apo
6. er Make sure the protection cover is in place after maintenance or repair The case is sealed failure to observe this instruction can result in damage to the meter Problem Check Solution The consumption There is no load Connect a load to the meter LED is not flashing connected to the PULSE LED meter hazard of electric shock The load on the line Check with an Ohm meter if the is very low load value is very low There is a fault If the checks above don t solve inside the meter the problem please contact technical support for a meter replacement PMMetering Rf 2011 125 PRO75A 100A MID User manual 0031 Problem The register doesn t count No pulse output The pulse output rate is wrong DMMetering R 2011 Possible cause There is almost no load connected to the meter iS a the Maybe there fault inside meter The pulse output is not supplied with DC power The pulse output is not connected correctly is a the there inside Maybe fault meter iS a the there inside Maybe fault meter 13 Check Solution Check if the green consumption LED is flashing 160 flashes of the LED at 1600 pulses per kWh equals 0 1kWh and should be clearly visible on the display Please contact technical support for a meter replacement Check the external voltage source Ui is 5 27V DC with a voltage meter Check if the connection is correct the 5 27V DC
7. gy meter is equipped with a pulse output which which is optically isolated from the inside circuit It generates pulses in proportion to the measured consumption for purpose of remote reading or accuracy testing The pulse output is a polarity dependent open collector transistor output requiring an external voltage source for correct operation For this external voltage source the voltage Ui should be 5 27V DC and the maximum input current Imax is 27mA DC To connect the impulse output connect 5 27V DC to connector 6 collector and the signal wire S to connector 5 emitter 16 5 emitter 6 collector DMMetering Rf 2011 11 PRO75A 100A MID User manual 0031 12 Troubleshooting A CAUTION During repair and maintenance do not touch the meter connecting clamps directly with your bare hands with metal blank wire or other conducting material as that will cause an electric shock and possibly cause injury serious injury or even death Turn off and if possible lock all sources supplying the energy meter and the equipment that is connected to it before opening the protection cover and working on it Turn off and lock all power supply to the energy meter and the equipment to which it is installed before opening the protection cover to prevent the WD no Maintenance or repair should only be performed by qualified personnel familiar with applicable codes and regulations Use insulated tools to maintain or repair the met
8. he device to the outside circuit should be sized in accordance with local regulations for the maximum amount of the current breaker or other overcurrent protection devices used in the circuit An external switch or a circuit breaker should be installed on the supply wires which will be used to disconnect the meter and the device supplying energy It is recommended that this switch or circuit breaker is placed near the meter because that is more convenient for the operator The switch or circuit breaker should comply with the specifications of the building s electrical design and all local regulations An external fuse or thermal cut off used as an overcurrent protection device for the meter must be installed on the supply side wires It s recommended that this protection device is also placed near the meter for the convenience of the operator The overcurrent protection device Should comply with the specifications of the building s electrical design and all local regulations This meter can be installed indoor or outdoor enclosed in a meter box which is sufficiently protected in accordance with local codes and regulations To prevent tampering an enclosure with a lock or a similar device can be used The meter has to be installed against a fire resistant wall The meter has to be installed in a well ventilated and dry place The meter has to be installed in a protective box if the meter is exposed to dust or other contaminants The meter c
9. logize Under normal conditions your product should give you years of trouble free operation In case there is a problem with the energy meter you should contact your distributor immediately Most of our energy meters are sealed with a special seal Once this seal is broken there is no possibility to claim any warranty Therefore NEVER open an energy meter or break the seal of the device The warranty period is 3 years after production and only valid for production faults PMMetering Rf 2011 i is PRO75A 100A MID User manual 0031 3 MID certificate KEMAZ CERTIFICATE EC Type examination certificate 09 4006 Authorised representative Inepro Metering BV Contact person D van der Vaart Address P O Box 92 Postal code Place 2450 AB Leimuiden Country The Netherlands Instrument Electronic single phase two wire energy meter Direct connected Type PRO 75A PRO 75D Register Mechanical LCD Accuracy Class E Ahi Measurement range 230V 10 100 A 50 or 60 Hz 1600 imp kWh Temperature range 10 40 C Use Indoor Protection Class os The energy meter meets the requirements of Directive 2004 22 EC of the European parliament and the council of 31 March 2004 on measuring instruments Certification was based on compliance with the following harmonised standards EN 50470 1 2006 Electricity metering equipment a c part 1 General requirements tests and test conditions Metering equipment class indexes A B and C
10. ng BV Of Inepro Metering BV Pondweg 7 2153 PK Nieuw Vennep The Netherlands Ensure and declare that the apparatus PRO 75A PRO 75D With the measurement range 230V 10 100 A 50 60Hz 1600imp kWh are in conformity with the type as described in the EC type examination certificate 09 4006 and satisfy the appropriate requirements of the Directive 2004 22 EC March 16 2009 ae lra Daan van der Vaart DMMetering R 2011 af PRO75A 100A MID User manual 0031 DMMetering Q 2011 5 Performance criteria Operating humidity Storage humidity Operating temperature Storage temperature International standard Accuracy class Protection against penetration of dust and water Insulating encased meter of protective class 6 Specifications Meter type Nominal voltage Un Operational voltage Insulation capabilities AC voltage withstand Impulse voltage withstand Basic current Ib Maximum rated current Imax Operational current range Over current withstand Operational frequency range Internal power consumption Test output flash rate Pulse output rate 7 Basic errors 8 Description 0 05Ib Cos 1 0 1Ib Coso 0 5L Cos 0 8C 0 1Ib Imax Cos 1 0 2Ib Imax Coso 0 5L Cosp 0 8C A Front panel B Cover C Base D 8 lt 75 lt 95 10 C 40 C 30 C 70 C EN 50470 3 1 IP51 II PRO75A 100A MID 230 AC 3 161 299V 4KV for 1 minute 6KV 1 2uS w
11. should be connected to the collector connection 6 pin and the signal wire S to the emitter connection pin 5 Please contact technical support for a meter replacement Please contact technical support for a meter replacement PRO75A 100A MID User manual 0031 13 Technical support For questions about one of our products please contact Your local Inepro Metering distributor Email support ineprometering com www ineprometering com RoHS COMPLIANT 2002 95 EC DmmMeteringR 2011 Le PRO75A 100A MID User manual 0031 This page is left blank on purpose DmmMeteringR 2011 15 PRO75A 100A MID User manual 0031 This page is left blank on purpose DmmMeteringR 2011 16 PRO75A 100A MID User manual 0031
12. tion can result in death serious injury or considerable material damage A will result in death serious injury or considerable material damage Qualified personnel Installation and operation of the device described in this manual may only be performed by qualified personnel Only people that are authorized to install connect and use this device who have the proper knowledge about labeling and grounding electrical equipment and circuits and can do so in accordance with local safety regulations are considered qualified personnel in this manual Use for the intended purpose This device may only be used for the application cases specified in the catalog and the user manual and only in connection with devices and components recommended and approved by Inepro Metering B V Proper handling The prerequisites for perfect reliable operation of the product are proper transport storage installation and connection as well as proper operation and maintenance During its operation certain parts of the meter might carry dangerous voltages Only use insulated tools suitable for the voltages this meter is used for Do not connect while the circuit is connected to a power or current source Only place the meter in a dry environment Do not mount the meter in an explosive area or exposed to dust mildew and or insects Make sure the used wires are suitable for the maximum current of this meter Make sure the AC wires are connected correctly before ac
13. tivating the current voltage to the meter e Do not touch the meter s connection clamps directly with your bare hands with metal blank wire or other conducting material as you will risk an electric shock that could cause possible injury serious injury or death e Make sure the protection covers are replaced after installation Maintenance and repair of the meter should only be carried out by qualified personnel e Never break any seals if present on this meter to open the front cover as this might influence the functionality or accuracy of the meter and will void all warranty e Do not drop or allow physical impact to the meter as there are high precision components inside that may break and affect the meter measurement negatively PMMetering Rf 2011 A a PRO75A 100A MID User manual 0031 e All clamps should be properly tightened e Make sure the wires fit properly in the connection clamps e If the wires are too thin it will cause a bad contact which can spark causing damage to the meter and its surroundings Exclusion of liability We have checked the contents of this manual and every effort has been made to ensure that the descriptions are as accurate as possible However deviations from the description cannot be completely ruled out so that no liability can be accepted for any errors or omissions in the information given The data in this manual are checked regularly and the necessary corrections will be included in subsequ