1. Display Functions Low Battery Detect Primary Display Secondary Display Auto Power Off Indicator Data Hold MAX Data Hold AVG Reading MIN Data Hold Relative Humidity C Temperature unit DEW POINT WET BULB SE AE ee F Temperture unit Sensor LCD C F Temperature unit and calibration button DEW POINT WET BULB Temperature button MAX MIN AVG Reading button Data hole button On Off button 4 6 MODE e During normal measurement press MODE button to switch temperature gt Dew point gt Wet bulb in sequence EN 3 TENMARS TM 730 4 7 CAL C F Button e Calibration point 55 RH and 25 C 1 Prepares 55 RH or 25 C environment 2 Press CAL button and POWER button more than 2 second to calibration 3 Put the meter in 55 RH or 25 C environment 4 Presses the MODE key to be select humidity or temperature humidity and temperature may alone adjustment 5 Press CAL button more than 2 second to complete the adjustment O 6 If must give up adjust please press the Wa key O Press this less than 1 second to alternative C or F unit 4 8 MAX MIN AVG Button The MAX MIN feature reads and updates the display to show the maximum or minimum or AVG value measured after you press the MAX MIN button Pressing the MAX MIN button for less than 1 second will put the meter into a mode of displaying the maximum minimum average readings Each time the MAX button Is pressed the meter will cyc
2. period of time remove the battery to avoid damage to the thermometer due to the leaking battery fluid e Cleaning and Maintenance Cigarette ashes and dust on the humidity sensor can slow down the sensor s response time while causing inaccuracy in measurements Clean up the sensor periodically by simply blowing away the dust particles Do not apply water or other chemical solvent like alcohol when cleaning e Do not place the Temperature Humidity Meter inside any liquid to prevent damage to the Thermometer 8 EMC C EMC EN61326 1 This product complies with requirements of the following European Community Directives 89 336 EEC Electromagnetic Compatibility and 73 23 EEC Low Voltage as amended by 93 68 EEC CE Marking However electrical noise or intense electromagnetic fields in the vicinity of the equipment may disturb the measurement circuit Measuring instruments EN 6 TENMARS TM 730 will also respond to unwanted signals that may be present within the measurement circuit Users should exercise care and take appropriate precautions to avoid misleading results when making measurements in the presence of electronic interference 9 Accessories e User manual e 1 5V battery AAA MN2400 LRO3 AM4 2 e Carrying case 10 Battery Replacement 1 Turn off the meter and slide out the battery cover 2 Remove the low batteries 3 Replace same type batteries 1 5V LR 03 AAA pi ee EN 7 TENMARS l
3. TENMARS Temperature Humidity Meter TM 730 User s Manual MODE C F MIN HOLD CE HB2TM7300001 TENMARS ELECTRONICS CO LTD CONTENTS DR arson exons nsec seer re a 1 2 CHARACLTERISTIE DS sen ee 1 3 SPECHTERTIONS see een 1 3 1 General Specifications QS A 1 3 2 Electrical Specification Temperature 25 C Humidity lt 90 RA 2 A e o PAPA 2 4 OPERATING INSTRUCTIONS seen 3 4 4 LCD Display Functions occccccccccccccccccccccccccceee eee eeesseeeeceeeee eee eeeeeeeeseeseeaaaaaeeeeees 3 4 5 Instrument AeSCHDUON nennen 3 SAS 3 47 CAMA PaO iaa 4 4 8 MAX MIN AVG Button oooonccccnnnnninninnonnnnncccnnnnnnnnnnnnnnccnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnns 4 49 Data Hold BUON ee rnit 4 420 TOWER DUO rosarino aceite eee EEE gt 11 AOL OW CP OO anne ee ee J 4 12 Enable Disable Auto Power Off ooccccccnnnnncnnnncccnnnnononnnnnnnnnnncnnnnnonnnnnnononnnnnnnnns 5 NAAA E Un E 5 O POCOSS OMICS arenero 5 7 A Warning and Precautions sosa ivi ei 6 S EMO AA E A A 6 O AA or A 7 10 Battery Replico nri taras 7 TENMARS TM 730 1 PREFACE Thank you for your patronage please read these operating instructions carefully so that you may correctly operate the Temperature Humidity Meter allowing it to perform all its intended functions at optimum level The Temperature Humidity Meter use a highly accurate sensor chip to measure relative humidity and temperature It is perfect for many industrial applications labor
4. atory and other types of work locations 2 CHARACTERISTICS e Dual display of temperature and humidity e C F alternate e Simultaneously hold both temperature and humidity readings e Simultaneously hold both maximum and minimum and average readings MAX MIN AVG e Auto power off e DEW POINT and WET BULB temperature measurement 3 SPECIFICATIONS 3 1 General Specifications e Display Dual LCD display The maximum value on the primary display is 999 The maximum value on secondary display is 999 e Low Battery Indicator When the LCD displays symbol please replace the battery e Sampling Rate 1 sample per second e Power Supply 2 batteries 1 5V AAA MN2400 LRO3 AM4 e Battery Life 50 hours during consecutive use e Dimensions 107 x 48 x 23 mm L x W x H EN 1 TENMARS TM 730 e Weight 80g excluding the battery e Accessories User manual battery and carrying case e Operating Temperature and Humidity 0 C 60 C lt 95 RH non condensing e Storage Temperature and Humidity 10 to 60 C lt 70 RH non condensing 3 2 Electrical Specification Temperature 25 C Humidity lt 90 RH e Temperature Measurement Range 20 0 C 50 0 C 4 0 F 122 0 F e Humidity Measurement Range 1 0 99 RH 3 3 Accuracy e Humidity 3 5 for 20 90 e 5 for 1 19 9 and 90 1 99 e Temperature 1 0 C 1 8F EN 2 TENMARS TM 730 4 OPERATING INSTRUCTIONS 4 4 LCD
5. le between MAX and MIN and AVG readings Press the MAX MIN button for more than 2 seconds to disable this feature 4 9 Data Hold Button Press HOLD button to enter the Data Hold mode The LCD will display HOLD symbol and hold both the temperature and humidity readings at the same time Press HOLD button again to exit this mode EN 4 TENMARS 4 10 Power Button 0 Press the amp 8 button more than 2 second to power on the meter 4 11Auto Power Off To save battery life the meter powers down automatically after approximately 12 minutes of inactivity 4 12 Enable Disable Auto Power Off You can disable or enable Auto Power Off by pressing the ww button more than 2 second the LCD N7 symbol will disappear or enable 5 End of life Caution This symbol indicates that equipment and its accessories shall be subject to a separate collection and correct disposal 6 Accessories e User manual e 1 5V battery AAA MN2400 LRO3 AM4 2 e Carrying case EN 5 TENMARS TM 730 7 Warning and Precautions e Please refrain from operating the Temperature Humidity Meter in an environment with drastic temperature and humidity changes Do not store the thermometer in an environment prone to high temperature high humidity or vigorous vibrations Avoid exposing the thermometer in a chemical contaminated environment e When not using the Temperature Humidity Meter for an extended
6. t gt Professional Electrical and Environment Test amp Measurement Instruments LED light meter Temperature amp Humidity meter Infrared Thermometer Sound level meter Light meter EMF meter UV Light meter RF meter Hot wire Anemometer Co meter Anemometer Lan cable tester Co2 meter Solar power meter Radiation meter Clamp meter Multimeter Phase Rotation tester Digital Insulation tester Our products of high quality are selling well all over the world TENMARS ELECTRONICS CO LTD 6F 586 RUI GUANG ROAD NEIHU TAIPEI 114 TAIWAN E mail service tenmars com http www tenmars com

Download Pdf Manuals

image

Related Search

Tenmars tenmars tm-197 tenmars tm-305u tenmars tm-204 tenmars tm-209m tenmars tm-508a tenmars tm-196 tenmars tm-103 tenmars tm-188 tenmars tm-6002 tenmars emf meter tenmars tm-301 tenmars tm-306u tenmars electronics

Related Contents

Phantom Tech HCPH0200000 User's Manual  IC Intracom 161527    ficha datos técnicos anticongelante gasoil concentrado  Mon mouton 1001 chansons    取扱説明書  Manual PDF  MANUAL FANTEC P2300  Italiano  

Copyright © All rights reserved.
DMCA: DMCA_mwitty#outlook.com.