Home
Diver Setup Guide
Contents
1. Default Export Settings File Type Y DAT f MON Project Setting E NITG File Name Format Location y Date y Serial Number y Export on Download Vertical Reference Datum Mean Sea Level y Here you can define the Project Settings such as the default Project Folder Vertical Reference Datum and Default Export Settings For more information on these settings please refer to the Diver Office User s Manual Take a brief moment to explore the Diver Office interface before proceeding with the next section Note the options in the Toolbar Place your mouse cursor over each button to display a tool tip describing each button s function In the next section we will define the communication settings 1 3 Selecting Communication Method Before you can communicate with Divers you must specify the appropriate communication method To do so e From the main menu go to Preferences Communication The following dialog will display PIE Select Reading Unit Port a Lancel Help From the dropdown list box select the appropriate reading unit port For example if you are using a USB Reading Unit select USB If you are connecting to a Diver that requires a serial port connection select the appropriate serial port After making the selection click OK 5 Diver Office Getting Started Guide 1 4 Viewing Diver Settings Now that the communication method has been defined D
2. Diver Office Getting Started Guide RE Schlumberger y WATER SERVICES Diver Office DESKTOP SOLUTION FUR MANAGING DIVER DATA Schlumberger 2007 Schlumberger Water Services Copyright Information O 2007 Schlumberger Water Services All rights reserved No portion of the contents of this publication may be reproduced or transmitted in any form or by any means without the express written permission of Schlumberger Water Services Printed in Canada 2007 schlumberger Water Services 2007 Table of Contents Htro uetlon as 4 Lauc hn a Dive OC Gi asa naka aa ad A ee RENT eT aha a 4 BA EPTO EC ea A Sa ec ET ent cnet tee nee Pree tenet errr ag Na a ng EN a a a Ag re te 4 Selectime Communication Methoden aka naeh 5 Vie wine DIY Ck SOU OS ada 6 POS O cases adele OE 7 Starting a DIVE zen ee er erkenne 7 STOP Pe a DIV aaa ata 8 Download View Diver TIIN A aana ga aa a a ee 8 Learnie more about Diver Office ara sa u u 9 3 Diver Office Getting Started Guide Introduction Diver Office 1s a software package developed to read and program Diver groundwater dataloggers download Diver monitoring data and process and display Diver data In combination with one or more Diver dataloggers Diver Office constitutes a complete and fleixble measurement system This document is designed to serve as a quick start reference guide for those interested in getting started quickly using the most common features of Diver Office In
3. ata will automatically export in the specified file types to the project folder Once complete Diver Office will add the location and its time series data to the Project Tree shown below schlumberger Water Services 2007 8 a Diver Office Sample Project u a gt lt Project View Preferences Import Help 2 9 N Bl New Open Diver Data Barocomp Help EX ample Project M mini_diver mini_diver A1862 05 12 2007 5 00 00 PM 06 12 2007 9 15 00 AM am Manual Measurements 5 05 12 2007 5 00 00 PM 06 12 2007 9 15 00 AM 999 998 D 3 3 3 6 238 3 S 997 S E 236 8 p T S 995 Y 104 a 232 5 994 bo ang r 6 00PM 8 00PM 10 00PM 12 00 AM 200 AM 4 00AM 6 00AM 8 00 AM v Pressure cmH20 v Temperature Celsius Settings Print Date amp Time Pressure cmH 20 Temperature Celsius December 5 2007 5 00 00 0 PM 990 8 24 54 December 5 2007 5 15 00 0 PM 991 4 24 51 o December 5 2007 5 30 00 0 PM 991 4 24 35 December 5 2007 5 45 00 0 PM 991 8 24 23 December 5 2007 6 00 00 0 PM 992 4 24 21 December 5 2007 6 15 00 0 PM 992 7 24 20 December 5 2007 6 30 00 0 PM 993 4 24 07 December 5 2007 6 45 00 0 PM 993 4 24 05 06 12 2007 y 917 124M Search The time series data will be displayed as both a plot and table in the adjacent window 1 9 Learnin
4. ds Immediate Start Future Start and Smart Future Start To read more about the various start methods please refer to the Diver Office User s Manual Once the desired start method is selected click the Start button The Diver status will now be shown as STARTED or FUTURE START in the Diver settings depending on which method was selected The Diver is now ready for deployment in the field 1 7 Stopping a Diver To stop a Diver e Ensure the Diver is placed in the reading unit a Fa e From the Diver dialog click the Settings button to display the current Diver settings The Diver status should be shown as STARTED You will notice that all of the settings fields e g Location Sampling Method etc are disabled e Next click the ow Stop button e A message will show warning you that all stored data will be lost upon restart shown below Diver Office x N IF the Diver is stopped the data will be lost upon restart Would you like to continue Ce we e Click the Yes button The Diver settings will be shown and the Diver status will be STOPPED 1 8 Download amp View Diver Data To download data from a Diver e Ensure the Diver is placed in the reading unit and that the settings have been read e Click the Data button While Diver Office downloads the data the download progress will be shown in a progress bar If the Export on Download option is selected in the Project Settings the downloaded d
5. g more about Diver Office This guide has introduced some of the more common tasks that can be performed in Diver Office To learn about Diver Office in more detail please consult the accompanying Diver Office User s Manual The User s Manual provides a succinct overview of all the Diver Office features including e Navigating the Project Tree o Location Settings o Manual Measurements o Time Series Plot settings o Printing time series o Searching time series data e Diver Communication o Start Stop Diver Start methods o Read Program Diver o Calibrate CTD Diver o Reading CTD Diver Calibration history o Reading Actual Data Data filtering Creating user defined pumping tests Data Import Export Changing Diver Office default units Barometric Compensation 9 Diver Office Getting Started Guide schlumberger Water Services 2007
6. iver Office can communicate with a connected Diver To read the settings of a Diver e Place a Diver in the reading unit e From the main menu go to View Diver or click the Diver button from the toolbar Diver Office will automatically read the Diver and display its settings in the Diver dialog shown below E Diver ja y DO xj a as k a ia de cy sO lt ki s Settings Data Start Program Calibrate Cal History Help Cera Diver STOPPED Serial Number Unit F Samples Taken pressure Temperature Celsius Battery Lett Firmware Version Range Location SWS Sampling Method Fixed Sampling Interval 05 Second 7 The Diver settings include Diver type Diver status 1 e Stopped Started Number of samples taken Battery life remaining Location name Sampling method and Sampling interval To read more about each Diver setting please refer to the Diver Office User s Manual The Diver dialog 1s the main interface in which you can communicate with Divers In addition to reading Diver settings you can Program Diver settings Start Stop Divers Download Diver data into Diver Office Read actual data from connected Divers schlumberger Water Services 2007 e Calibrate CTD Diver The next section describes how to program settings to the Diver 1 5 Programming a Diver You can change the settings of the Diver by editing the available fields and sa
7. this guide you will become familiar with the following functions Creating a Project Selecting Communication Method Viewing Diver Settings Starting a Diver Stopping a Diver Downloading Diver Data Viewing Data VVVVVV V Before proceeding be sure that you have successfully installed Diver Office and the device drivers for the Diver Reading Unit or Interface Cable Also make sure the Reading Unit or Interface Cable is connected to your computer 1 1 Launching Diver Office Once Diver Office has been installed on your computer launch the application by following the steps below e Go to Start Programs SWS Software Diver Office e Alternatively double click on the LI Diver Office short cut located on your desktop 1 2 Creating a Project Upon launching Diver Office for the first time you will be prompted with a Create Project dialog shown below Ei Create Project D x Project Mame _ Enter the name of the project and click Create Note If this is not the first time launching Diver Office from the main menu go to Project New to create a new project Once created the main Diver Office interface will display shown below schlumberger Water Services 2007 0 x Main Menu gt gt Projet View Preferences Import Help i G Toolbar New Open Diver Data fiak Sample Project rect Sili Sample Project Project Folder Project Tree EADwerOfice Sample Prec Wg Window
8. ving the new information to the Diver To do so e Ensure that the Diver is placed in the reading unit e Specify the new information for the desired fields Note Only Location Sampling Method Sampling Interval Altitude CTD Only and Conductivity Range CTD Only settings can be modified A e Once the new settings have been entered click the s Program button from the toolbar Diver Office will now save the new settings to the connected Diver You can verify that the settings were programmed by reading the Settings of the Diver 1 6 Starting a Diver Once the settings have been programmed the Diver can be started When a Diver is started it takes and stores samples based on the specified sampling method and interval defined in the Diver settings To start a Diver e Ensure the Diver is placed in the reading unit a e From the Diver dialog click the sO Start button Depending on the sampling interval defined in the Diver settings you may be prompted with a warning message indicating the estimated operating time of the Diver If this message is shown click the Yes button The Start Diver dialog will display shown below Start Diver Dila A This action will eraze all data on the Diver i Immediate Start Future Start EA AN aji E O Smart Future Start ms yne Clock Start Cancel Help 7 Diver Office Getting Started Guide Here you can select from three different start metho
Download Pdf Manuals
Related Search
Related Contents
Lenovo X301 User's Manual 取扱説明書 Bedienungsanleitung Instructions for use Istruzioni per l algo3 ifu.indd intext:Betriebsanleitung filetype:pdf Télécharger la documentation Piaggio Quargo, Véhicules Utilitaires Ocularis Client Lite Manual K163 通信取扱説明書 DV 480 User Manual Copyright © All rights reserved.