Home

UltraView IP XP4 Box Day/Night Range Camera User Manual

image

Contents

1. your workstation e Add the camera s IP address to your browser s list of trusted sites To add the camera s IP address to Internet Explorer s list of trusted sites 1 Open Internet Explorer 2 Click Tools and then Internet Options 3 Click the Security tab and then select the Trusted sites icon 4 Click the Sites button UltraView IP XP4 Box Day Night Range Camera User Manual 9 Clear the Require server verification https for all sites in this zone box Enter the IP address in the Add this website to the zone field Click Add and then click Close Click OK in the Internet Options dialog screen O N oO Connect to the camera for full browser functionality Accessing the camera over the internet The camera can be configured using an internet browser such as Microsoft Internet Explorer IE You must have administrator rights on your PC in order to configure the camera over the internet To view camera images via a Network Video Recorder or similar digital video system please refer to the documentation associated with that system To access the camera online 1 Configure your host PC laptop within the same subnet as the camera s default IP address for example 10 1 2 10 2 In the Web browser enter the camera s default fixed IP address 10 1 2 11 The login dialog box appears 3 Enter the username and password Login admin Password admin 4 Click OK The UltraView IP XP4 box day n
2. 6 interlogix UltraView IP XP4 Box Day Night Range Camera User Manual P N 1234568A EN REV 1 0 ISS 19DEC12 Copyright Trademarks and patents Manufacturer Certification FCC compliance ACMA compliance Canada European Union directives Contact information 2012 UTC Fire amp Security Americas Corporation Inc Interlogix is part of UTC Climate Controls amp Security a unit of United Technologies Corporation All rights reserved The UltraView name and logo are trademarks of United Technologies Other trade names used in this document may be trademarks or registered trademarks of the manufacturers or vendors of the respective products UTC Fire amp Security Americas Corporation Inc 2955 Red Hill Avenue Costa Mesa CA 92626 5923 USA Authorized EU manufacturing representative UTC Fire amp Security B V Kelvinstraat 7 6003 DH Weert The Netherlands CE Onn Class A This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area
3. Use this menu option to check the status and configuration of the camera and network parameters Using the mouse click the Monitoring option in the menu toolbar The screen displays five icons By default the Health Metrics screen is shown Clicking each icon will list the relevant values underneath The system date and time must be set up using a NVR server in order for the date and time to be synchronized Click the Refresh button on the bottom of the screen to update the information displayed UltraView IP XP4 Box Day Night Range Camera User Manual 11 Figure 6 Monitoring screen Health metrics shown Health Metrics Live View Administration Restart Health Metrics L I n 7 y System Configuration Video Ports Network Interfaces CPU Temperature 57 C Core Voltage 1 20 V 41 2 V 1 20 V 18 V 1 80V 5V 4 94V 12 V 12 2 V Free memory 51976 kB CPU usage 27 System Date amp Time 01 01 2003 03 05 11 UTC Uptime 0 day 3 05 28 Table 4 Description of the Monitoring screen Icon Function Healt Herca Health metrics Description Displays the health status of the camera The items listed are CPU temperature C Core voltage Power supply voltage 1 2 V Power supply voltage 1 8 V Power supply voltage 5 V Power supply voltage 12 V Free memory CPU usage System data and time A red value means that the device is not synchronized with an NTP server Uptime Valu
4. ed when connected to the IP system To connect the cables 1 Connect a coaxial cable from the camera s BNC connector to a CCTV monitor or video recording device 2 Connect a PoE switch a 12 VDC or 24 VAC power supply to the power input Do not connect both the PoE connection and DC or AC connection at the same time Setting the camera DIP switches You can set up six camera functions using the DIP switch bank on the rear of the camera Figure 4 below shows the DIP switch layout See Description of the DIP switch settings on page 8 for information on these functions Figure 4 DIP switch layout located on rear of camera Table 3 DIP switch functions Switch Description 1 White balance ON ATW mode OFF PTL mode 2 Backlight compensation ON BLC on OFF BLC off 3 Al AE exposure ON Auto exposure AE mode OFF Auto iris Al mode 4 Day Night setting ON Black and white mode OFF Auto Day Night mode 5 High Normal Resolution ON High resolution OFF Normal resolution 6 Flickerless control ON Flickerless enabled OFF Normal UltraView IP XP4 Box Day Night Range Camera User Manual 7 Description of the DIP switch settings White balance WB White balance tells the camera what the color white looks like Based on this information the camera will then display all colors correctly There are two methods to determine the WB e ATW auto tracking white balance The value used depends on the li
5. es displayed in green are normal Those in red are abnormal UltraView IP XP4 Box Day Night Range Camera User Manual Icon Function System configuration Video ports Ry Widen Ports Network interfaces i z r lt ia Network Configuration Description Displays information on the system configuration and status The items listed are Equipment name Serial number of the device Software revision U boot revision Software recovery revision Displays information on the video ports status and configuration The items listed are Label TCP port Format Shows PAL or NTCP Size FPS Frame rate Bandwidth Status Normal status is displayed in green Abnormal status is displayed in red Displays information on the network configuration and status The items listed are Type IP Mask Cable status TX packets TX errors MAC address Default Gateway Ethernet configuration Rx packets Rx errors Configuring the camera and network Use this menu to configure the camera and network parameters Using the mouse click the Administration option in the menu toolbar The screen displays five icons By default the Network Configuration screen is shown Clicking each icon will display a different screen that allows you to configure different parameters See Figure 7 on page 14 The system will prompt you to reboot in order for any changes made to take effect Click Restart in the toolbar to reboot the s
6. focus adjustment Lens auto iris lens shown Manual lens has no cable Not included Back focus lock screw Auto iris lens cable Not included Attach a manual lens using an auto electronic shutter AES lens or attach an auto iris Al lens Mounting the camera To mount the camera attach the camera to the prepared mounting surface using the appropriate mount UltraView IP XP4 Box Day Night Range Camera User Manual Connections Figure 2 Rear panel of camera 74 mm 2 91 in fo ee a an camo 1 Power LED 5 Alarm input and output 5 PResetbuttom Connect to be able to trigger an alarm at Press to reset camera to factory default EO MECH RENCE settings 6 Power supply 3 Ethernet RJ45 port Connect 12 VDC or 24 VDC power supply Connect to network devices 7 Video output 4 DIP switches Connect to a CCTV monitor Configure camera settings Alarm connection Figure 3 DC alarm input and output wiring 1 OUT 2 GND 3 Table 2 Description of alarm connections Alarm input Type TTL Compliant with 48 V input voltage Connector type Screw terminal Alarm output Type Open collector Compliant with 48 V external power Connector type Screw terminal 6 UltraView IP XP4 Box Day Night Range Camera User Manual Connecting analog cables Connect a standard CCTV monitor to the system to adjust the quality of the video image using the DIP switches The DIP switches can also be adjust
7. ghting condition selected It ensures reliable color reproduction when lighting conditions change frequently e PTL push to lock white balance WB is fixed at the moment the DIP switch it set to ON Backlight compensation BLC The backlight compensation function improves image quality when the background illumination is high It prevents the object in the center from appearing too dark Al AE exposure Use this setting to select the method the camera uses to adjust to different light levels Day Night This function controls if the camera switches to day night mode The camera produces high quality color video during the day or when light levels are high It then switches monochrome and removes the infrared filter to improve IR sensitivity at night or when light levels are low Resolution High resolution produces higher quality images but also increases the file size of video images Flickerless control Flickerless control eliminates the flicker caused by the differences between the frequencies 60 Hz of the ionization of the gas in a fluorescent light bulb with that of the vertical frequency 59 95 Hz in the camera Although the difference is very small it results in a slight flicker at the top of the monitor scene or in video over IP applications it would be interpreted as motion Flickerless control helps reduce the file size and transfer bit rates of compressed video images Reset button Use this button to reset
8. guration of IP Address IP Address NetworkMask s i i s Broadcast Address PO Gateway Address rt O Table 5 Description of the Administration screen Icon Function Description Network configuration Defines the network parameters b ae You can assign an IP address either automatically or we manually by selecting one of these options DHCP For automatic installation check the box acs cs DHCP Auto Configuration of IP Address This option is disabled by default Static IP For manual installation enter the IP address Network mask Broadcast address and Gateway address values The default IP address is 10 1 2 11 Click the Apply button to save the changes 14 UltraView IP XP4 Box Day Night Range Camera User Manual Icon Function ay Video port format DS Video Ports Change administrative Er password ri Chan pe Germs eb EL File firmware update Fis firmware wodete Configuration download Description Defines the video format used PAL or NTSC Check one of the format boxes Click OK to save the changes Note This parameter is unavailable if the camera has been configured through a Central Configuration Server or VisioWave Security Center Defines the administrative password used to access the system The factory default admin password is admin It is recommended that is this changed for security reasons Note Keep the admin password in a safe place If y
9. ight range camera home page appears Overview of monitoring and configuring the system Use the menu toolbar on the top of every screen to access the various screens for monitoring and configuring the camera There are five options e Home Return to the home page e Live view View images in live mode e Monitoring Display information on the health of the device system configuration video ports and network interfaces See Monitoring the system on page 11 e Administration Define the network parameters access rights and video formats See Configuring the camera and network on page 13 e Restart Restart the device This is required for example to reboot the system for changes to be implemented However if the network connection is lost as a result of the configuration changes made you must reconfigure the 10 UltraView IP XP4 Box Day Night Range Camera User Manual camera by pressing the Reset button on the rear of the camera The settings return to factory default The menu toolbar with these options is displayed along the top of all screens so is always easily available Live viewing Use this menu option to view live mode Using the mouse click the Live View option in the menu toolbar Click the Stop button to stop live view and then the Play button to restart it You can watch different video streams in live view However these must be first set up in the VisioWave CSS system Monitoring the system
10. is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Notice This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures This Class A digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la class A conforme a la norme NMB 003 du Canada 2004 108 EC EMC directive Hereby UTC Fire amp Security Americas Corporation Inc declares that this device is in compliance with the essential requirements and other relevant provisions of Directive 2004 108 EC 2002 96 EC WEEE directive Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union For proper recycling return this product to your local supplier upon the purchase of equivalent new equipment or dispose of It at designated collection points For more information see www recyclethis info For contact information see our Web site www interlogix com or www utcfssecurityproducts eu Content Introduction 2 Product description 2 Features 2 Installation 3 Installation environment 3 Package contents 3 Cable requirements 3 Setting up the camera 4 Camera description 5 Lenses 5 Mounting the camera 5 Connections 6 Alarm connection 6 Connecting analog cables 7 Setting the camera DIP switches 7 Description of the DIP switch set
11. not overload the power cord or adapter e Ventilation Ensure that the location planned for the installation of the camera is well ventilated e Temperature Do not operate the camera beyond the specified temperature humidity or power source ratings The operating temperature of the camera is between 30 to 50 C 22 to 122 F Humidity is below 90 e Moisture Do not expose the camera to rain or moisture or try to operate it in wet areas Turn the power off immediately if the camera is wet and ask a qualified service person for servicing Moisture can damage the camera and also create the danger of electric shock e Servicing Do not attempt to service this camera yourself Any attempt to dismantle or remove the covers from this product will invalidate the warranty and may also result in serious injury Refer all servicing to qualified service personnel WARNING To reduce the risk of fire or electronic shock do not expose the camera to rain or moisture and do not remove the cover or back Package contents The camera is shipped with the following items e The camera assembly e 1 channel passive video transceiver e AC power wiring harness e 150mm DC jack to terminal adapter Cable requirements For proper operation adhere to the following cable and power requirements for the cameras Category 5 cabling or better is recommended All network cabling must be installed according to applicable codes and regulations UltraVie
12. ou should forget it you must reset the camera configurations to default by pressing the Reset button on the rear of the camera In the Enter old password edit box enter the current admin password In the Enter new password edit box enter the new admin password and confirm it Click the Change administrative password button to save the changes In the menu toolbar then click the Restart option The Restart screen appears Click OK to reboot the system to implement the changes Updates the firmware The camera firmware is stored in the flash memory Use this option to write the firmware into the flash memory When you upgrade the firmware all existing settings are unchanged Only the new features are added with their default settings Click the Browse button the locate the updated firmware and then press the Upload firmware file to start the update Lists all the configuration information You can download it to a file on your computer or another location Click the Save the configuration button to download this information and enter the download destination UltraView IP XP4 Box Day Night Range Camera User Manual 15
13. the camera to factory defaults including camera and network settings With the camera powered on press the red reset button for 10 to 15 seconds The red LED indicator light flashes when the reset signal is accepted 8 UltraView IP XP4 Box Day Night Range Camera User Manual System configuration This chapter explains how to configure the camera through a Web browser Software requirements The UVC IP camera requires e Microsoft Internet Explorer e A VLC player ActiveX plug in is required to play video when Internet Explorer is used to monitor the camera Figure 5 ActiveX plug in option E YLT meia player 04 fle etn i sicj x Chooce Components n howe vtech Teau of 40 mete ppa 00 Ba wy ard ip rata pes Check the components wou sart bo etal and uncheck the components wou dont went to mia Chick Nest fp conto Select the ype of meta Cr palant thw optional Media Pier requeed pe pec ha EE Start Manu Shorbout ne Desktop Shortnya Hoa chn A Active phan file type associations Space required SSB The WLC Actives plugin Windows Vista and 7 users Internet Explorer for Windows Vista and Windows 7 operating systems have increased security measures to protect your PC from any malicious software being installed To have complete functionality of the Web browser interface with Windows Vista and Windows 7 do the following e Run the Browser interface and the DVR player application as an administrator in
14. tings 8 System configuration 9 Software requirements 9 Windows Vista and 7 users 9 Accessing the camera over the internet 10 Overview of monitoring and configuring the system 10 Live viewing 11 Monitoring the system 11 Configuring the camera and network 13 UltraView IP XP4 Box Day Night Range Camera User Manual Introduction Product description The UltraView IP XP4 box day night range camera uses a digital signal processor DSP to process video signals The video camera includes a microcontroller to provide high quality images with high color reproduction and sharp pictures Product codes e UVC IP XP4DN HR UVC IP XP4DN HR P Features Camera features include e H 264 SVC video compression with multistream capability e Pixim Seawolf technology e Excellent performance in almost any lighting conditions e Supports up to 4CIF resolution 540HTVL analog e True day night removable IR cut filter e Long life and high reliability e DIP switch control of camera settings e Power over Ethernet PoE or Isolated switching power 12 VDC or 24 VAC 2 UltraView IP XP4 Box Day Night Range Camera User Manual Installation Installation environment When installing your product consider these factors e Electrical Install electrical wiring carefully It should be done by qualified service personnel Always use a proper PoE switch or a 12 VDC or 24 VAC UL listed Class 2 or CE certified power supply to power the camera Do
15. w IP XP4 Box Day Night Range Camera User Manual 3 Table 1 below lists the requirements for the cables that connect to the camera Table 1 Recommended cable requirements Cable type Requirements Video 75 ohm RS 59 coaxial cable with BNC ends Power 24 VAC cable Setting up the camera Note If the light source where the camera is installed experiences rapid wide variations in lighting the camera may not operate as intended To quickly put the camera into operation 1 Connect the lens to the camera 2 Prepare the mounting surface and mount the camera to the wall ceiling using the appropriate fasteners 3 Connect the cables to the camera 4 Connect a CCTV monitor to the system to program the camera 5 Set the camera s DIP switches which are located on the rear of the camera to suit the camera s location See Setting the camera DIP switches on page 7 6 Set up the camera s network and streaming parameters so that the camera can be controlled over the network See Accessing the camera over the internet on page 10 4 UltraView IP XP4 Box Day Night Range Camera User Manual Camera description Figure 1 Side view of XP4 box camera 1 Auto iris lens connector Video type auto iris lens connection A Video white B Power C NC D GND black DC type auto iris lens connection A Driving coil B Damping coil C Damping coil D Driving coil Lenses oa Camera Back
16. ystem UltraView IP XP4 Box Day Night Range Camera User Manual 13 Figure 7 Network configuration screen Home Live View Monitoring Administration Restart Network Configuration WY amp B Video port format Change administrative File firmware update Configuration download password Network Configuration Important Notice e Network settings will take effect on the next system restart e ifthe system becomes unreachable because of an IP address or network configuration problem you can try the default IP address 10 1 2 11 255 255 255 0 or you can push the reset factory button to reset all settings to default Should include the domain name if applicable Fully Qualified Host Name DISCO_42000010210000000018 localdomain Comma separated list of DNS servers ip addresses Primary server first DNS less operation is supported with the restriction that other equipments and the CCS must be configured with static IPs DNS Server When an hostname is specified with a domain the domain of this host will be searched and additionally the comma separated list of domains in this field DNS Search Path These fields should only be modified when replacing an existing Discovery This allows for the replacement of a Discovery without any intervention on the Central Configuration Server C This box is a replacement Central Configuration Server CCS Equipment Name DISCOVERY 105 FACTORY SETTINGS CI DHCP Auto Confi

Download Pdf Manuals

image

Related Search

Related Contents

MMX A106 PFD User Manual.  Manual Disponível - Metalúrgica Siemsen  authorization and Release of Medical Information, Notice of Privacy  OPERATING INSTRUCTIONS  Operation of the Covaris E  Mode d`emploi - Projectionniste.net    CAPÍTULO 8. INSERTAR Y ELIMINAR ELEMENTOS  User`s Manual - General Technologies Corp.  FA-95LG取扱説明書[PDF:2.9MB]  