        Home Security System User Manual
         Contents
1.    Command  On  17   1   Off  17  0  System default  Off    10    8  Turn on off the function of anti decode   In order to prevent people from decoding the alarm system  it is  recommended to turn on this function  Disarm only by the keypad   Command  On  18   1   Off  18   0   System default  Off    9  Turn on off the reminder for phone line trouble   It will warn you if the phone line is cut or short circuit  It will sound three     beep    every 10 seconds    Command  On  22   1   Off  22   0   System default  On    10  Set the ringing times   Call the alarm host  after the ringing circle  it will get through  automatically  At this time  you can remote control the alarm system  For example  set the circle times as 04  and then you dial the number of  the alarm system  it will get through after you hear 4 times of the ring   Command  12  XX      XX shows times of ring  from    00  12     00 means the host will not get  through and you can not remote control the system  System default is  00     11  Set the alarming time of siren   You can set alarming time of the siren according to the use   s request  from 0 to 30 minutes    Command  29   XX      XX is 00   30minutes  System default  01 minute     11    12  Turn on off the warning tone of remote controller   Turn on this function  the siren will make a short beep each time you  press the remote controller    Command  On  8  Off  8  System default  On    13  Reset   Reset means deleting all registered information including
2.  e  Fe    Glass Sensor Panic Button Remote Controller  j  N  e J    nni y  Wireless Smoke Gas Detector Wireless Pet  Detector Immune PIR Detector    Optional sensors detectors are packed separately  You can choose  according to your specific requirements     15    Typical house configuration           Door window   Garage          smoke      T PIR Movement  Detector  lt  Detectors    VI  Technical Parameters   Main Panel   Power Supply  AC  220V 10   DC  9V   Inside Battery  Ni MH rechargeable battery  DC 7 2V   Working Current   lt 50mA   Alarm Current  s300mA   Wireless Receiving Frequency  315 4833MHz 0 5MHz   Wireless Receiving Sensitivity  5mV m   Anti jamming Intensity  1V m  frequency range  20 1000 MHz    Outside Alarm Siren  110db   Working Condition  Temperature   10  C   40  C  Relative Humiditys90    Detector Capability  99pcs    16    Wireless Door  Window Detector   Power Supply  DC12V  built in 12V battery   Static Current   lt 20uA   Transmission Current   lt 15mA   Transmission Frequency  315 433MHZ 0 5MHZ  Transmission Distance  No obstacle 80m   Alarm Distance  15mm   Working Condition  Temperature  10  C   40   C  Humidity  lt  90  rh    Wireless PIR Detector   Power Supply  DC9V  built in 9V battery   Static Current   lt 100uUA   Transmission Current   20mA   Transmission Frequency  315 433MHZ 0 5MHZ  Transmission Distance  No obstacle 80m  Detective Speed  0 3 3m s   Detective Distance  5 12m   Detective Range  Horizontal 110   Vertical 60    Working Con
3.  passwords   All the settings will return to the original status    Command  0000       IV  Operation Instructions    pan              1  Out Arm     Press the    Out amO  button on the remote controller or press    Out       button on the main panel for 2 seconds  30 seconds later  there will be a     beep    and the OUT LED on the main panel will flash  The system  enters Out Arm mode  and all the detectors will be in working status     12    2  Home Arm     Press the    Home am     button on the remote controller or press       Home    button on the main panel for 2 seconds  30seconds later  there  will be a    beep    and the Home LED on the main panel will flash  The  system enters Home Arm mode  Detectors inside the house  in inner  defense zone  will not work  only the detectors outside the house  in  outside defense zone  will work  so that people inside can move freely   but others who break in from outside will trigger the alarm     3  Disarm     Press    Disarm O     button on the remote controller or input       password disarm    by the main panel  the system will enter into  disarmed status     4  Emergency     When there is an emergency  press the    Emergency D     button on the    remote controller or the main panel  the system will alarm immediately    no matter it is in arm or disarm status     5  Receive alarm call   When there is an alarm  the siren will start ringing  the    alarm    indicator  on the main panel will light up  the defense zone indicator 
4.  send SMS to the numbers    Command    31  the 1st User phone number     32  the 2nd User phone number     33  the 3rd User phone number     34  the 4th User phone number     35  the 5th User phone number     36  the 6th User phone number     38  the 1st phone number of monitoring center     39  the 2nd phone number of monitoring center     Note  Do not setup the monitoring center number if you do not have   monitoring center  You can enter a blank order if you want to delete one   Alarm Phone Number    Fox example  To delete the 4th Alarm Phone Number  input 34       Operation sketch        Input password  default 1234       Alarm Phone No  Settings     31  the lst User phone mmber    32  the 2nd Usty phone mmber    33  the 3rd User phone number    34  the 4th User phone mmber    35  the Sth User phone mmber    36  the 6th User phone mmber    38  the lst phone mumber of  monitoring center     39  the 2nd phone mumber of  monitoring center         Record Voice Message                      4  Change password  Command  10 password   password must be 4 digits   This password is used for remote control     The following are special settings   5  Defense zone setting    You can set the type of defense zone according to your needs  The  system default is    Instant Zone    for all zones  Only wireless zone     01 08     and wired zone    91 97    can be set    Command    Zone No    2  X          X is zone type    0    Closes Zone  do not send detecting information    1    Instant Z
5. Home Security System       User Manual    Profile  For a better understanding of this product  please read this  user manual thoroughly before using it     Warning    Do not remove the front or back cover of the unit and keep it  intact  There is no part that can be repaired by user  If repair  is needed  please send it to seller or authorized service  point    The information contained in this manual is prepared for the  alarm system only  It adopts a sustainable development  strategy  Therefore  the company retains the right to modify  or make improvement to any product described herein  without giving prior notice  All rights reserved  The name of  other companies or products referred to herein may be the  brand or product name of their respective owners     Thank you for purchasing this alarm system  For proper use and your safety  please  read these instructions thoroughly and carefully before you put the system in use   Keep this manual carefully for your reference in the future     Precautions    Please read and follow the brief instructions below  otherwise physical danger or  system damage may be incurred  This manual contains more detailed information  about safety issues concerning the system in other parts hereof        Proper use Waterproofness Q Qualified    maintenance service    Read this manual The alarm system is Only those qualified  carefully before you put not waterproof  maintenance professionals  the system in use  Please keep it dry  may repair the ala
6. M  and the other to 1  or 2  or 3     or 7      lt  gt     1         e   ye oom tm Nw e U    eeeeleelsleis e    zone 91  the 1st wired detector    GND   12V            zone 92  the 2nd wired detector    Function settings   Before any operation  please enter passwords  Default is 1234   and press button    PROGRAMME     You will hear two beeps and  the OUT ARM  HOME ARM LED light up  indicating the system  enters set up status    Each time you input an instruction  hearing two beeps means  successful  If you hear four short beeps  it means false operation   You have to try again    Please press    EXIT    to end the set up status  System will exit  automatically if there is no operation for 30 seconds    Record alarm message    Input    6     to start record message after hearing a beep  After 10    seconds the system exits recording with two beeps automatically  Each    new recorded message will replace the last message  The message    should be short and clear  For example     This is room xxx building xxx     intruder  please come to offer help     Press    6     on the main panel  it will    play the recorded message through the telephone     2  Add or delete wireless detectors   Each detector has its unique ID  It must be coded with the main panel   for normal working  If it is not coded with main panel  the main panel   would not identify it and could not receive the signal  so the alarm will  fail    The door sensor and the remote controller in the standard kit have bee
7. dition  Temperature  10   C   40   C  Humidity  lt  90  rh    Remote Controller   Power Supply  DC 12V  built in 12V battery   Static Current  0   Transmission Current  15mA   Transmission Frequency  315 433 0 5 MHz    17    Transmission Distance  No obstacle 80m    Working Condition  Temperature  10  C   40  C    Relative Humiditys90     VII  Care and Maintenance    The alarm system has excellent design and used advanced    technologies  It shall be used with care  The following suggestions are    required to maintain your obligations under the warranty terms  and for    prolonging the service life of the system      gt      gt     Place the control panel and all parts and accessories out of  children   s reach   Keep the alarm system dry  Rain  humidity and various fluids or  moisture all will corrupt the electronic circuit   Do not use or place the alarm system in dirty locations  otherwise  the electronic elements will be damaged   Do no place the system in excessively hot locations  High  temperature will shorten the service life of electronic equipment   damage batteries  deform or even melt some plastic parts   Do not place the system in excessively cold locations  Otherwise  condensation many occur and damage the circuit board of the  alarm system   It is recommended that you check and test the alarm system  periodically    Check the main unit every three months    1  Whether it can arm disarm normally    2  Whether it can dial the number for alarm normally     3  Whe
8. itter   Then adhere them to the appropriate position    Magnet should be near to the side of transmitter with indicator   The two should align with each other and the distance should not  exceed 10mm    Please plug out the antenna for better signal    If the low power indicator is on  please change the battery     3  Wireless PIR    PIR detectors are  used to detect the    detector    window                   movement within a    a  certain range  door   lt   Fix the adjustment bracket on the wall with the provided screws    s    and attach the detector to the bracket  It is recommended to  mount it at a height of 2 2 2m above the floor    Effect of the PIR detection is best when the detection direction is  in 90  angle with the walking direction of the intruder  Choose the  most suitable installation place and angle according to actual  situation and taking the following installation diagram as reference  to ensure the detection effect is best    Please do not fix it under direct sunlight or other strong lights and  also keep it away from places with frequent strong air stream    If the low power indicator is on  please change the battery     4  Wired detectors  At the back side of the host  there is a wired connector which can link    with 7 wired detectors     The  12v and GND are to connect with the power supply  the COM is    the public port  When using the wired detectors  connect the  12v and    GND to the power supply  connect one line of the wired detector to the  CO
9. lem for you as soon as possible     19    Brief list of setting command                                                                                  Description Command Remarks  Record alarm message 6   Replay the message 6   Code wireless detectors 7   Delete wireless detectors 7   Set Alarm Phone Numbers    31 35  phone  number   Set monitoring center    38  39  number  Do not set it if do not have  number a monitor center   User password 10 new password  new password should be 4  digits  default  1234  Zone No   01 08 91 97  X indicates zone type   Defense zone type  zone No  2 X   1  instant  2  delay  3   urgent  5  inner  0  close  Defense zone warning    zone No  71  ON  tone  zone No  70  OFF  System Default   Remote controller warning   8  ON  System Default  tone 8  OFF  Anti interference 17 1  ON  17 0  OFF  System Default   Anti decode 18 1  ON  18 0  OFF  System Default   Telephone line trouble alert   22 1  ON  System Default  22 0  OFF  Ringing times 12 XX  XX  00 12  default  00  Siren alarming time 29 XX  XX  00 30 minutes   default  01  Reset 0000        20       FAQ          Problems Causes Solutions  i   _ Arm the unit  1  Hasn   t armed  2  Operate after 30  2  Less than 30 seconds  seconds    Cannot alarm by phone    after arming   3  Set wrong phone  number   4  The two parts of  door window sensor is  installed too far from  each other   5  Haven t activated PIR   6  Hasn t checked code    3  Set the number  again according  to the manual   4  Adju
10. lephone  line with the port of    out line    and    telephone    with the telephone  set  That is to say  the telephone must be connected with main  panel  The telephone can still work normally    b  Power the system on and switch it to    ON     the power status LED  will blink and the system sounds    beep     showing the main panel  works normally  It will sound three    beep    every 30 seconds  which    reminds user of setting alarm phone numbers  The sound    beep     will stop after finishing the alarm phone number setting  Please    press        on the remote controller to make the system    disarmed to avoid activating the siren to alarm when registering    sensors     defense zone indicator             power    switch 1       siren   H     telephone     out line                        Attention      gt      gt      gt     2     Door sensors are used  for detecting the status  of open and close of  windows and doors  lt  will detect it and send  the signal to main    panel      gt     Try to install the main panel in the center of defense zone and pull  out the antenna to get longer wireless receiving distance   Installation position should be far away from huge metal objects  and wireless interference    Connect the trunk line with main panel in order that it can dial out  immediately when there is an alarm     Install the main panel in a hidden place     Door sensor          less than    hmm   Tear apart the   double side adhesive tape on the magnet and the transm
11. n   coded to the main unit  If you want to add more wireless sensors    please refer to the instructions as follows    a  Input    7      there will be a beep and the ARM status LED starts  flashing  The unit enters coding status  Now you can start to  register sensors by triggering the new sensors or detectors  It  means successful operation if you hear two beeps  The unit will  exit automatically if there is no operation for 3 minutes    b  How to trigger the detectors    Door sensor  separate the two parts  PIR detector  move across the   detector  remote controller  press any key on it  gas and smoke   detectors  there is a black switch on the left side  you can press it to  code it with main panel  After finishing coding  please press         to exit    two beeps     c  Delete sensors   In coding status  input    7      you will hear    beep  beep     At this time  all   coded information has been deleted     There are 32 defense zones  so you can install sensors in any of  defense zone  You will know what sensors are triggered from the  screen of main panel  You can input XX  and then trigger sensors and  then enter into this defense zone     For example  if you want to code the detectors and sensors into the 2nd    or 4th defense zone  do as follows             Enter 7  and trigger sensors   zone 2  Enter 02   and trigger sensors   SS     gt   Zone 4  Enter 04   and trigger sensors Dawa                3  Set alarm phone numbers  when the system alarms  it will call or 
12. one  default  alarm immediately if triggered    2    Delay Zone  alarm 30 seconds after being triggered    3    Urgent Zone   It will alarm if triggered  no matter it is in arm or    disarm status     5    Inner Zone   In    home arm    situation  it won t alarm if detectors are  triggered     E g   If you want to set the second defense zone to be inner zone  You  can input   0225     Suggestions    Usually  we set the door window sensors installed around windows   balcony and doors as    Immediate Zone     The detectors in this area will  activate alarm in any mode of arming    Set wireless PIR detectors as    Inner Zone     they will work in the mode  of    Out Arm     but do not work in the mode of    Home Arm       You can set the door sensors at the main gates as    Delay Zone    if you  do not want to take remote controller when going out  In this case  you  can disarm the system within 30 seconds after opening the door  but  the alarm system will not activate during this period     6  Turn on off warning tone for defense zone   If you turn on the warning for defense zone  it will    beep    for three times  to remind users of arming the system before going out    Command  On    Zone No  71   Off    Zone No   70     System default  Off    7  Turn on off the function of anti interference   When turning on the function of anti interference in arming status  it  will activate siren to alarm  not calling users  if someone interferes the  alarm system with the same frequency
13. rameters    Care and Maintenance    11    11    11    12    12    12    12    13    13    13    14    14    16    18    10     11   12     13     14     Features  Anti interfere function  when someone interferes it with the same  freguency  the main panel will activate siren to alarm   Support anti decode with remote control  Digital LED defense zone display  users can know which  defense zone is triggered   32 wireless defense zone display  1 to 32  and 7 wired defense  zone display  91 97    Every defense zone can set independently arm  disarm  delay  alarm and so on   Have the function of    one button arm        Home arm    or    Out arm     by pressing one button on remote controller   Can set the reminder sound of defense zones  warn users to arm  the alarm system when going out   Can work with other products of our company  such as wireless  big outdoor siren and mini siren   It stores 2 monitoring center and 6 user phone numbers to dial  out and play the recorded message when alarming   Can arm  disarm with remote controller or keypad on the main  panel   Can arm disarm listen in by calling the main panel number   Telephone line failure alert  if telephone line is cut or short circuit   the siren will alarm   Have the superior of alarm call even when the alarm phone  number is busy   Built in backup battery can continue to work when electricity is  cut off or in failure     l  Installation   1  Main panel   a  Insert the siren to the port of main panel  and connect te
14. rm system     Operate in accordance  with the instructions herein     Backup Original parts and   Addition of    batteries other equipment  Be sure to back up all Only original parts and Before adding other  important information batteries approved by equipment please read the  stored in the system  manufacturer may be used  user manual for detailed    otherwise the warranty term safety instructions Be sure  may be breached and danger not to connect incompatible  may occur  products to the system     AAN Switch on safety Interference Switch off in    restricted areas    Do not switch the Device All wireless devices may be Follow any restrictions    on when wireless phone susceptible to interference  Switch the device off in  use is prohibited or when which could affect aircraft  near medical   it may cause interference performance  equipment  fuel  chemicals   or danger  or blasting areas     Catalogue    Features   Installation   Main panel   Door Sensor   Wireless PIR Detector  Wired Detector  Function Settings  Record alarm message  Add or Delete Wireless Detectors  Set Alarm Numbers  Change password    Defense Zone Setting    9    9    Warning Tone for Defense Zone 10    Anti interference    Anti decode    10    11    Phone Line Trouble Reminder  Ringing Times Setting   Siren Alarming Time   Remote Controller Warning Tone  Reset   Operation Instructions   Out Arm   Home Arm   Disarm   Emergency   Receive Alarm Call   Remote Control by Phone  Components List   Technical Pa
15. st the  installation place  of the door  sensor   5  Activate the PIR   6  Check code again       Remote controlling  distance is too short and  the light indicator is not  on bright enough    1  The battery of remote  controller is rusty  2  Low battery    1  Clean the rust  Change battery    N       Light indicator of door  sensor and PIR is always  on     Low power battery    Change battery       Dial alarm number slowly    The main panel has stored  other numbers    Set it again according  to the operation  manual          The main panel cannot  receive signals from the  accessory    1  Low power battery in the       accessory    2  There is block between the    control panel and the  wireless accessory or the  distance between them is  too far    3  The accessory has not    been coded to the panel       1   2     Replace the battery   Pull out the antenna  of the accessory and  the main panel  and   adjust the position    3 Code it to the main    panel       21       
16. ther it can receive wireless detectors    signal normally    18    4  Whether the back up battery can work normally   Check the wireless detectors once a month   Trigger wireless detectors to see if system can alarm normally   Check all detectors    batteries to see if it   s in low voltage   Check whether wireless detectors can send signal to the main  unit normally      Since the alarm system is continuously in operation or standby  mode  the supply adaptor of the control panel shall be connected  to a safe and reliable socket     lt   Do not place the system near your bedroom or office table   because the siren will make high loudness sound in the case of  alarm  which may adversely affect your rest or work     lt   If the alarm system will not be used for a long time  please  disconnect the system from the power supply     lt   Please do not disassemble  repair and alter the products without  permission  or it may cause accidents and faults     lt   Do not drop this product on the ground or on hard objects  as it  may lead to massive impact to cause faults and damages     lt   Without approval and consent of relevant authorities  please do  not set    110        119    or the alarm phone number of police station for    this main unit     Please read the suggestions above carefully and follow the instructions  herein  If any of the equipment does not work properly  please send it to  the dealer or authorized service point for repair  We will try our best to  solve the prob
17. will display  the number  and the system will make alarm call  After answering the  call  user will hear the recorded message  and then can do the following    13    operations   Press    listen in for 30 seconds   You will hear what is happening at the  alarm spot    Press    confirm that you have received the alarm and the system will  stop alarm   If you do not input    the alarm system will continue to dial out all alarm    phone numbers circularly     6  Remote control by phone   You can call the host phone number to remote control the system  After  getting through  input    passwords          If the password is correct  the  system will sound    beep    twice  If wrong  it sounds    beep    four times    And then you can control the system with following commands   Press    1    to arm   make sensors working    Press    2    to disarm  make sensors stop working    Press         to listen in for 30 seconds  for continued listen in  press          again to listen in for another 30 seconds    Press         to exit    Note  The system will hang off automatically if passwords are wrong for  3 times or not any operation for 20 seconds     V  Components list    Main panel 1 pc   Remote controller 2 pcs   PIR sensor 1 pc     14    Door sensor 1 pc     Siren 1 pe   Power adapter 1 pc   Phone cable 1 pc   User manual 1 pc     The following sensors are optional       Ba oo     amp  e    Wireless Outdoor  Signal Repeater Wireless keypad Siren with flash    v          fa  ce  ws  i
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Sterile Oil for Tissue Culture Sterile Oil for Tissue Culture  Tecumseh AE2410A-AA1ASC Drawing Data  C - Site de la ville de Valenton    リンク構成 DDL、S-設計  FLIR K40/K50のマニュアルはこちら  SH PMG-W SH PRC-W PanaMag  AF-92 HEATER MODULE AF-93 CHEMICAL  02_P.C. Analizador Espectros (ABR0022  P iastra ro tan te    Copyright © All rights reserved. 