Home

Sinewave Inverters

image

Contents

1. EE 11 19 Trouble SHOOTING e 12 20 Overview protection features and automatic recovery after failure 13 21 FIR 13 22 Further assistance and sending the unit for repair L nn nnn nn nn 13 23 NoteS EE 14 Manual Jazz doc 3 14 Version 1 1 4 General Information Thank you for choosing a product supplied by RIPEnergy AG The product you have bought is manu factured to meet the highest quality standards Our manufacturers have a very long experience in manufacturing of high end electronic equipment 5 Use of this manual This users manual contains the information you need to install and operate this inverter correctly Check that you have the correct manual for your unit It is valid for the following units Sinewave Inverter Jazz 700 12 230 and 700 24 230 and 700 48 230 Sinewave Inverter Jazz 1000 12 230 and 1000 24 230 and 1000 48 230 Read the manual carefully before installing or operating the inverter If you do not under stand or are uncertain about any operation or information please contact your dealer He will be able to help you with an explanation or will demonstrate the operation The user must always have access to the user s manual The latest version of the manual is provided and can be downloaded from the homepage of RIPEnergy AG These inverters must be only installed by qualified authorized and trained personnel fam
2. 12 230 4 25 100 1000 12 230 2 35 150 700 24 230 6 15 60 1000 24 230 4 25 80 700 48 230 6 15 30 1000 48 230 6 15 40 Use ring terminal to assemble DC Cables and to connect the cable to the terminals of the inverter Torque to tighten the terminal screws is 12 13 Nm Connect the other end of assembled DC Cables with care to the battery inline fuse If possible use coloured cables Red colour means battery positive while black is used for battery negative Revers ing positive and negative will cause major damage to the inverter and is not covered by warranty Note Large capacitors in the units may hold DC Voltage for a long period of time Also a spark may occur while connecting the DC cables or inserting the DC Fuse after installation This is normal If you connect other consumers to the battery contact your dealer 13 4 AC Wiring Use the included AC Connector to connect the AC Load to the output of inverter Even the inverter is protected against overload and short circuit we recommend to use an AC Circuit breaker of correct size For safe operation it is necessary to connect earth PE and neutral N of the inverter output to central ground of the inverter Even more safe is to use a 15mA or 30mA earth leakage switch in the AC Installation Manual Jazz doc 8 14 Version 1 1 13 5 Grounding The earth wire protection is only possible if the inverter enclosure is also connected to earth Use a 8 10mm
3. the power draw required The inverter is affordable to supply surge power for a short time so as to start up electrical equipment such as pumps motors etc Some equipment needs more power while starting up The inverter is protected against overload and will switch off automatically when overload is applied As ambient temperature is above 20 C the inverters nominal power may be smaller due to reduced cooling Using the inverter in high altitudes may also reduce nominal power of the inverter because of less heat discharge As a rule of thumb the reduction of nominal power is approximately 1 596 per 100m eleva tion 13 2 Installation These units must be only installed by qualified authorized and trained personnel familiar with the locally applicable standards and taking into consideration all relevant safety guidelines and measures Before installing the unit check for correct DC Voltage and power level of the inverter The Inverter may be installed in any position Install the inverter in a dry well ventilated and dust free location It must be installed out of reach for unauthorized personnel especially children s Do not in stall the inverter in the same compartment as the batteries Never use or install the inverter in locations where there is gas or explosive danger For proper cooling of the Inverter ensure that the airflow is not obstructed and keep a clearance dis tance of 2 5cm to other units If the inverter is installed in
4. 0VDC Input Case 1100VDC Protection Short circuit Overload Output Case 500VDC circuitry Overtemperature i Overload Overtemperature Indicators Loadlevel Red Orange Green Power Factor 0 4 1 COS Phi Length 38 3 cm Nominal voltage VDC 12 24 48 Width 18 2 cm Voltage range VDC 10 5 15 21 30 42 60 Height 8 9 cm Amps Pnom A 91 45 22 Clearance 2 5 cm all around Protection circuitry Overvoltage Low voltage Material Aluminium Idle current 230V ON A 14 0 7 0 36 Finish Black Anodize Powder Epoxy Coat Idle current sleep A 0 25 0 125 0 06 Weight 4 0 Kg Efficiency max 9196 93 95 Connections DC clamps AC connector Efficiency full load 8696 8996 9196 Connector supplied with inverter Overvoltage Lowvoltage Warranty 2 years Battery level Red Orange Green Standards Approval to CE e Mark Manual Jazz doc 11 14 Version 1 1 19 Trouble shooting Warning Never remove the cover of the inverter Do not self repair the inverter no serviceable parts are inside the unit No function Check LED Display to identify the reason According the failure indicated by the display see sections below to solve the problem Check wiring for correct size damage or loose screws Check batteries battery fuse or fuse installed on AC output If switch is in remote position but no remote control unit is connected switch it to the ON Position DC Low voltage The battery voltage dropped below 1 75
5. 2 cable AWG 8 and connect it to the earth terminal of the inverter This is also important for lighting protection 14 Remote control unit The optional available remote control unit enables remote control of the inverter The remote control unit must be connected to the remote port located on the rear side of the inverter Before using the remote control unit the main switch of the inverter must be in the remote position We recommend to use the optional available remote panel Deluxe or remote panel Standard The cable to connect this unit to the inverter is included when you order such a remote unit 15 Configure the inverter prior to operation 15 1 Frequency setting The AC Frequency may be selected by DIP Switch S4 on the front panel as follows AC Frequency Hz S4 50 0 60 To activate the new selected value the inverter must be turned ON and OFF Reset 15 2 Sleep mode Power saving mode automatic load detection Trigger level for seep mode is adjustable and set by the DIP Switches S1 S2 and S3 on the front panel as follows o N o Co Trigger level W S1 Sleep mode disable 7 15 20 28 35 42 ol ol jol o 50 To activate the new selected value the inverter must be turned and OFF Reset Caution If the inverter is detecting a load it may take a
6. 9 Environmental protection arrari nara aan iann RAAKA AAEE TATARAN AAAA AAA AAS RAR IAPAA SAREKAT ARAARA 5 10 Description of the INverter ka AAE EVAAA AARRE ANKAA ASERNE 5 Td E e A eee ER nn 6 12 t Safety Information itd e dada d dla etii pa a 6 12 1 General informatlon ia iate er ta Fi ire dpa aida RE aac 6 12 2 Working with batteries 000 seen nanna ann AAAS AANEREN nnne nnne 7 13 Planning and mounting the inverter sse 7 13 1 Required power draw ME AANEEN 7 13 2 AEE E na C 7 13 3 Beute 8 ISA v AGZWirltIgu si etes Re EL DLE rue te eI 8 13 5 roufidiridgsssss o deest ceste a ELM LA LESE e 9 14 Remote ontroliumiti 3 meo tee tentiae dee eden ide ttu 9 15 Configure the inverter prior to operation 2 snanar ann nr nnne 9 15 1 Frequency setting A eoe teli dide etin 9 15 2 Sleep mode Power saving mode automatic load 9 16 7Operatio i issu sie cse g e DE Tor store Te c EA cere reer 9 17 SBED DISPIAY c5 A epa edet eaedem dieses 10 17 1 Status LED e a o aU a Rice AT MEM cE ot Gert i 10 17 2 Input Level BED ie d BA i 10 17 3 Load Level LED aio ee olo era e RR RE 10 18
7. Sinewave Inverters Jazz 700VA and 1000VA User s manual 1 Warranty RIPEnergy is not manufacturer of these units All technical information s data s and dimension s rely on information s given by the manufacturer Therefore RIPEnergy AG is not responsible for the data s provided in this manual Should work take place which is not in accordance with guidelines local rules instruction s or specification s damage may occur All of these matters will lead to loss of war ranty RIPEnergv AG can not accept any liability for damages or costs arising due to the use of these inverters 2 Distributor s address RIPEne The power conversion company RIPEnergy AG W gitalstrasse 24 CH 8854 Siebnen Schweiz Tel 41 0 43 818 5385 Fax 41 0 43 818 53 87 Email info ripenergy ch Internet www RIPEnergy ch 3 Retail dealer s address Date of purchase Manual Jazz doc 2 14 Version 1 1 Contents 1 lur 2 2 Distributors address cree teat e o s eto tese ta etae un een ee tecta redd 2 3 Retail dealers address Date of purchase nn nn rna nennen 2 4 General Information rtt teret D ecce te ee etaed Pr iet redd 4 5 Use ofthis mantalean ette ea teste et etes tacto er etu bee Lond 4 6 Limitation of labllity eret ce ote tet ttai ek de tet ta etes er de 4 7 Warranty specifications short form ennemis 5 8 LE 5
8. V Cell Check battery fuse Charge the battery if charging is not solving the problem maybe the battery is defect The wiring may be too thin or check installation for loose connections Note If battery voltage rises above 2 1V Cell the inverter restarts automatical ly DC Over voltage The battery voltage is above 2 55V Cell Remove the battery charger and stop charging the battery Note If battery voltage is dropping below 2 5V Cell the inverter restarts auto matically Over temperature If load is smaller than nominal power of inverter check if ventilation of the inverter is blocked Maybe the ambient temperature is too high If load is exceeding nominal power of inverter reduce the load Note The inverter will switch on automatically if temperature of the inverter is within normal operating temperature range Overload Reduce load Remove unnecessary consumers Reset the inverter with the front panel switch OFF than ON Other failures Check system for correct grounding or contact your dealer V Cell The nominal voltage using lead acid batteries is 2VDC Cell Example A 12V Battery contains 6 single cells a 24V Battery contains 12 single cells etc Manual Jazz doc 12 14 Version 1 1 20 Overview protection features and automatic recovery after failure DC Input Overvoltage Lowvoltage i VDC Lowvoltage VDC emperature Shut Re
9. a closed compartment the nominal power may be reduced In order to keep the battery cables as short as possible max 3m locate the inverter close to the DC Distribution or Battery Be aware that during charging of batteries an explosive gas can be generated Manual Jazz doc 7 4 Version 1 1 13 3 DC Wiring Position of the switch on the front panel must be OFF Caution First connect the assembled DC Cables with the inverter and in a second step connect it with the battery Always connect first the neutral wire with the battery A high power fuse must be installed direct to the battery to protect the DC Wiring DC current ac cording to the table below Not installing a fuse may result in melting or even burning DC Cables in case of excessive overload or failure of the inverter The way of wiring has influence on the EMC behaviour of the system Most problems using inverter are because of unprofessional wiring Lay the cables in a metal duct If this is not possible the cables should be twisted and lay parallel to a metal bar To thin cable or loose connections can cause dangerous overheating of cables or terminals Always use DC cables of the correct size to avoid fire and other damage To define the size of cable we provide a Cable Size Calculator on our website for free use You may use the following recommendations for best performance of inverter Inverter DC Cable AWG mm2 Inline fuse A 700
10. and the latest technology of the units will ensure a long lasting and trouble free operation of these units If any problem occurs during warranty period please contact your dealer first He is able to serve you with instructions and explains you how to send the unit to the nearest service center if necessary Warranty can only be guaranteed if you enclose a document Invoice or delivery documents to the defective units Damage attributable to normal wear and tear overload or improper handling or installation is not cov ered by the warranty Modifications or breaking the warranty label without a written permission from RIPEnergy AG means that the warranty is lost immediately Always return the units in it s original package and completely assembled A short description of the failure problem will help us to serve you better see also instructions on item 20 RIPEnergy AG is not paying for costs arising for transport of the unit or damage that arise during the time the unit is unserviceable The general terms of delivery and terms of sale of RIPEnergy AG are valid 8 Unpacking After unpacking carefully check the inverter for possible damage If any damage due to transport is visible immediately contact your dealer for further instructions Keep the original packing in case you need it to transport the inverter later 9 Environmental protection RIPEnergy AG continually commits a considerable part of its resources towards minimizi
11. ch can produce arks and sparks To prevent fire or explosion do not install or operate in compartments containing batteries or flammable materials Never use or operate the unit where there is danger of gas or dust explosion Manual Jazz doc 6 14 Version 1 1 After automatic shut down of the inverter because of any failure the inverter may switch ON automatic again The OFF period is depending on what causes the shut down and may vary from only seconds to several minutes 12 2 Working with batteries Using batteries in a wrong way may result in danger for personnel animals or the environment Check information from battery manufacturer for safe installation and operation If battery acid contacts skin or clothing wash immediately with soap and water If acid contacts eyes immediately flush with running cold water for at least 20 minutes and get medical attention as soon as possible Never smoke or allow a spark or flame in vicinity of batteries Do not drop metal tools on batteries The resulting spark or short circuit may cause an explosion Remove personal metal items such as rings bracelets necklaces and watches when working with batteries 13 Planning and mounting the inverter This section will provide you information s about configuring and installing your inverter Make sure that you are aware of local rules and safety measurements 13 1 Required power draw Before connecting your appliances to the inverter always check
12. ds and rules applicable to use such equipment For installation and use of the inverter pay attention to local applicable standards all relevant safety guidelines and measures These rules may be different to the information s provided in this manual High voltages up to 1200V inside the inverter Never open the enclosure High voltage may harm or even kill persons or animals Never touch wires or blank connectors Do not operate the inverter with damaged or substandard wiring Warning While sleep mode is active the inverter AC Output is active and high voltage is present at the AC Output To detect a load the inverter is sending 230VAC Pulses to the AC Output Check local standards for lightning protection of inverter systems No other inverter output AC Generator or other AC Source may be connected to the inverters AC Output The inverter will be destroyed immediately The enclosure may heat up to 80 Never obstruct louvers nor place other items on the inverters enclosure If ventilation is not sufficient the unit may overheat and an automatic shut off may occur Even if DC Wiring is not longer connected to the batteries inbuilt large capacitors may hold Dc Voltage for an extended period of time The inverter may only be opened by skilled and authorized personnel Modifications or breaking the warranty label without a written permission from RIPEnergy AG means that warranty is lost immediately The inverter contains components whi
13. ection Short circuit Overload Output Case 500VDC circuitry Overtemperature Overload Overtemperature Loadlevel Red Orange Green 04 1 Indicators Power Factor Nominal voltage VDC Voltage range VDC Amps Pnom A Protection circuitry Idle current 230V ON A Idle current sleep A Efficiency max Efficiency full load 10 5 15 21 30 65 31 Overvoltage Lowvoltage 0 82 0 125 9296 8796 9396 8996 95 91 Mechanical Specifications Length 29 5 cm 7 5cm 2 5 cm all around Aluminium Height Clearance Material Finish Black Anodize Powder Epoxy Coat Weight 2 9 Kg DC clamps AC connector Connections Connector supplied with inverter indicators Overvoltage Lowvoltage Warranty 2 years Battery level Red Orange Green Standards Approval to CE e Mark 1000VA Nominal VAC 220 230 240 selectable 3 Operating Temp 10 to 40 C maximum output Output Frequency 50Hz 60Hz selectable 0 05 Range Derating Linearly 4 per C from 40 C Nominal power 1000VA continous Humidity 0 95 Relative Humidity non condensing Nominal current 4 33A 230VAC nominal Power Audible Noise Odb 1m Fan OFF Power for 3 min 1150VA Fan Load and temperature controlled Peak Power 1300VA 65 C ON 45 C OFF Output Waveform Pure Sinewave Isolation Input Output 110
14. few seconds before the output power is avail able delayed Be careful when working with machinery we recommend to disable the sleep mode 16 Operation The Inverter is controlled by a single three position switch located on the front panel of the inverter Engaging Switch to ON Position The green LED will illuminate The Inverter is ready to use Power down Switch to OFF Position All LED s are dark The inverter output is OFF or Standby with sleepmode Warning If sleep mode is active the inverter AC Output is loaded with a 230VAC test puls every 800ms Manual Jazz doc 9 14 Version 1 1 Remark Even if the inverter is switched to off it is not disconnected from the battery It still draws very little power from the battery If you don t need the inverter for an extended period disconnect it from the battery to avoid low discharge of battery Before using the remote control unit to control the inverter the main switch must be in the REMOTE Position 17 LED Display 17 4 Status LED Steady green 580 cd o eh di pe sd B A etd is AC Output OK Flashing slow green nn nn Sleep mode active Load detection active Flashing fast red Cut Off caused by DC Over voltage Flashing slow Cut Off caused by DC Low voltage Letero VAN e EARE creer Cut Off caused by overload Flashing intermittently red see Cut Off caused b
15. icate showing date of purchase and a short notice about your system and the failure observed 5 In case you have to send the unit above state borders please make sure to fill the correct pa pers needed for customs To reduce time and save money contact the consignee how to de clare the delivery Arising costs for customs has to be paid by the sender An actual list of authorized service center will be provided at our homepage www ripenergy ch Manual Jazz doc 13 14 Version 1 1 23 Notes Manual Jazz doc 14 14 Version 1 1
16. iliar with the locally applicable standards and taking into consideration all relevant safety guidelines and measures Never remove the type number plate Important technical information required for service or delivery of spare parts can be derived from the type number plate gt EJ AG means that warranty is lost immediately N Modifications or breaking the warranty label without a written permission from RIPEnergy Always contact your dealer first if you have any problems 6 Limitation of liability RIPEnergy is not responsible or liable for any loss damage or costs arising from operating these inverters The products supplied by RIPEnergy AG are not for application s in any medical equipment intended for use as a component of any life support system If products are used in such systems a specific written agreement between the manufacturer RIPEnergy AG and the installer manufacturer of the system is needed In addition the manufacturer of the system must agree to indemnify RIPEnergy AG from any claims arising from use of products supplied by RIPEnergy AG in the life support equipment Manual Jazz doc 4 14 Version 1 1 Warranty specifications short form The inverters are built for RIPEnergy AG in according to the legally applicable standards During pro duction and prior to delivery all products are tested and inspected RIPEnergy AG is looking to find the best available products on the market Good quality parts
17. ng the envi ronmental impact of its products The inverter is manufactured with valuable materials and easy to recycle 10 Description of the inverter The model Jazz 700VA and Jazz 1000VA pure sinewave inverter supplies a 230VAC output voltage either from a 12V 24V or 48VDC power source The shape of the output voltage is pure sinewave clean power as from the grid The inverter design is based on state of the art high frequency technology All functions are controlled by a microprocessor Extra input and output filtering to reduce EMI to extremely low levels Reliability features include an input fuse thermal shutdown current limiting and output short circuit shutdown with automatic recovery The input and output is fully isolated The superb overload capability supplies short time peak power to start heavy equipment such as pumps and compressors Manual Jazz doc 5 14 Version 1 1 11 Block Diagram Power Board AC Filtering DC Source supply etc DC Filtering Battery Fuel Cell Wind PV Power AC Consumers TV PC Fridge Light Pumps etc Internal Power Microprozessor Supply Board Remote Display Unit Input Output 12 Safety Information 12 1 General information Read the manual carefully before installing or operating the inverter If you do not understand or are uncertain about any operation or information please contact your dealer Before installation you must be aware of local standar
18. start Alarm Shut Restart Shut Restart down Down down 1000 12 110 1000 12 230 15 3 14 2 11 0 10 5 12 5 1000 24 110 1000 24 230 30 6 28 4 22 0 21 0 25 0 85 C 45 C 1000 48 110 1000 48 230 12 56 8 44 0 42 0 50 0 21 Maintenance Only little maintenance is required to keep your inverter and system operating reliable The inverter must be switched off during maintenance and or repair activities It also must be secured against un expected and unintentional switching on Therefore switch off the connection between batteries and inverter and be sure that third parties cannot reverse the measures taken The following Steps must be undertaken at least once a year Check cable and wires for damage and if they are still firmly connected Defects such as loose connections ore damaged cables etc must be corrected immediately Keep the inverter dry clean it from dust in order to ensure good heat dis charge 22 Further assistance and sending the unit for repair In the rare case the unit is not working contact your dealer providing him some details as 1 Check Battery voltage wiring and display for possible failures 2 Note Type of unit and serial number 3 Now call your dealer or nearest service center They will help you with further instruction s 4 fhe is recommend to send the unit for repair use the original packing Include a copy of invoice Warranty repair is only possible with a copy of invoice or certif
19. y over temperature 17 2 Input Level LED The input level indicator shows the DC Input voltage of the inverter Remark The DC Input voltage may be less then the battery voltage The longer and thinner the DC Cables voltage drop in the cable is higher when the load is big LED Status Version 12V Version 24V Version 48V Flashing slow red 10 5 10 9 21 0 21 8 42 0 43 6 Steady red 10 9 11 3 21 8 22 6 43 6 45 2 Steady orange 11 3 12 0 22 6 24 0 45 2 48 0 Steady green 12 0 14 0 24 0 28 0 48 0 56 0 Flashing orange 14 0 14 7 28 0 29 4 56 0 58 8 Flashing red gt 14 7 gt 29 4 gt 58 8 17 3 Load Level LED LED Status Output Power VA 1000VA Output Power VA 700VA Dark 0 50 0 40 Green 50 330 40 250 Orange 330 750 250 550 Red 750 960 550 680 Flashing red 960 gt 680 Manual Jazz doc 10 14 Version 1 1 18 Technical data 700VA Nominal VAC 220 230 240 selectable 396 Operating Temp 10 to 40 C maximum output Output Frequency 50Hz 60Hz selectable 0 05 Range Derating Linearly 4 per C from 40 C Nominal power 700VA continous Humidity 0 95 Relative Humidity non condensing Nominal current 230VAC nominal Power Audible Noise NONE Odb 1m Fan OFF Power for 3 min 800VA Fan Load and temperature controlled 65 C ON 45 C OFF Output Waveform Pure Sinewave Isolation Input Output 1100VDC Input Case 1100VDC Prot