1. C RcWare SoftPLC Room unit configurator 16 6 2 2 Humidity Dec set places may be 0 1 or 2 number of decimal places to display when changing a setpoint Min Max Minimum and maximum limits for changing the temperature setpoint May also be relative such as Min 3 5 Max 3 5 C The interpretation must be programmed at the master device Corr Internal correction adds to the measured temperature before it is displayed and send to the Modbus table The default value of 1 5 C compensates the internal heat dissipation within the room unit Step Value to change setpoint on one step of the knob The knob has 24 steps to complete one turn Set outside temp Outside temperature at which heating mode starts Symbols Thermometer Empty house This temperature can be set by the user and then read by master for further processing in the primary heating circuits It is set in whole degrees no decimals in the Min Max range Min Max Minimum and maximum limits for changing the outside temperature to start heating Set DHW temperature Setpoint of domestic hot water Symbols Water tap This temperature can be set by the user and then read by master for further processing in the DHW preparation circuit It is set in whole degrees no decimals in the Min Max range Min Max Minimum and maximum limits for changing the DHW temperature setpoint Set heating curve Type of heating curve relation between outside temperature
2. below Open close initialization only relevant for initialization process see below 5 2 Tabs with setpoints and parameters At the right of the window there are tabs with advanced controller settings Only use those settings when necessary All settings are effective immediately and written to RAM Permanent writing to EEPROM follows by clicking the Write all to EEPROM button see above Settings RcWare SoftPLC Room unit configurator 7 5 2 1 Temperatures Controller settings Seral port settings Temperature Digital Presence mode Symbol control Set temp 10 00 JE Set dav temp 23 00 E Set night temp 15 50 L Set depress temp 10 00 SE Set day cool temp 25 50 alte Set night cool temp 35 00 a Set depress cool temp 35 00 SE Min temp 18 00 JE Mast temp 30 00 JE Min d n d temp E Max d n d temp 35 00 ER Corr temp 1 50 JE Corr out temp 0 00 JE Shep temp 0 50 E EEN HEN SER BEN m mom mm EN zm Set temp Actual set temperature It is updated only when the properties window is opened For information only Set day temp Heating setpoint for Day Comfort mode Set night temp Heating setpoint for Night Standby mode Set depress temp Heating setpoint for Off Depression mode Set day cool temp Cooling setpoint for Day Comfort mode Set night cool temp Cooling setpoint for Night Standby mode Set depress cool temp Cooling setpoint for Off Depression mode Min temp Minim
3. is used for addressing and configuring of all Modbus based Domat Control System I O modules room units and room controllers It is used by system engineers for pre configuration in the office as well as by commissioning staff for I O check and controller settings Domat exe runs in the Microsoft NET V2 0 environment the NET files must be installed prior to running the software No installation of domat exe is necessary just copy the files exe dll and data txt into any suitable directory E ESS RicWare SCADA Runtime Shared dll b kE 26 9 2007 13 38 ESG RcWare STADA Runtime Channels Clentlpdatechannels dll z6 kE 26 9 2007 13 38 ESG RcWare SCADA Runtime Drivers Modbus dll 36 kE 26 9 2007 13 38 Domat 1 0 4 5 6x6 1 588 kE 21 4 2008 13 00 data txt 1k65 21 4 2008 15 00 3 Hardware configuration Connect the room unit I O module or IRC controller to serial port of your PC through a RS232 RS485 converter e g Domat M011 Power all components by 10 30V DC or 12 24 V AC domatexe eq UIO11 See data sheets for terminals and correct module connection bus end etc 4 Module detection Run domat exe The main program window opens RcWare SoftPLC Room unit configurator 3 Diet j O x Info E Mo Hr COM3 End adress 100 Budae 9600 gt Service code Parity None gt TO one al User mode Data bits B Scan gt NB The program should open in User mode see i
4. its enabled states see below None if the unit is given a short push nothing happens Tenner Humidity Digital Settings Modes Symbol control Show mode MM Temperature CF Show time 2 00 Humidity Edit retum time 10 00 Time Long push time 1 50 Remote 0 l Remote 1 Quick edit mode Hone Presence mode Day night mode Fan Heat cool mode Probably the most important part of the functionality of the unit After the unit is given a long push it switches to the Edit mode In the Edit mode it is possible to select different parameters and change them The selection follows by turning the knob The active parameter together with its symbol set is flashing If you want to change a particular parameter give a short push The symbols stop flashing and the parameter can be changed by turning the knob Confirm the parameter by a short push and select another parameter to change As soon as you have finished settings give a long push which switches the unit back to the Show mode Inactivity time longer than Edit return time also switches back to Show mode Here in the Modes tab the engineer selects which modes are relevant for his application and what the user will be able to change E g it apparently makes no sense to enable humidity setpoint if no humidity control is installed The Modes tab incorporates several subtabs Switch between the subtabs clicking on the lower brink of
5. This means that the user can change room temperature setpoint outside temperature at which heating is enabled or disabled and heating curve type Those values can be read out by the master No other values are available for the user except those for display selected in the Show mode Another modes are in the other subtabs Enable each of those modes if the user is allowed to change it Enable the mode also if it should be changed in the Quick edit mode Check the states that the user may select from For instance on the screenshot below the user only can select between Comfort and Standby modes however the presence mode can be set to Off remotely from the master Comfort maximum heating and minimum cooling temperature all aggregates are functional Symbols Occupied house Standby Temporary absence Symbols Empty house Off Long term absence holidays weekend room unoccupied etc Symbols Off symbol RcWare SoftPLC Room unit configurator 20 Party Temporary occupancy long office hours etc Should be set back to Standby after a certain time usually 2 hours by master Temperature Humidity Digital Settings Modes Symbol control Disabled W Comfort TET Standby TT Off T Paty A Others Presence mode Day night mode Fan Heat cool mode 6 2 7 Day night mode Temperature Humidity Digital Settings Modes Symbol control Disabled gt Disabled C Day auto E Might auta a D
6. UART but over an internal USB interface even if the notebook has the CANNON 9 Male connector Then the driver does not catch the fast responses of the modules typically M4xx M300 etc Try another notebook or communicate over the process station Another reason may be a non standard type of RS232 RS485 converter Try M011 if not used Unknown module type May appear when using older versions of domat exe which do not support certain module room unit types Download the latest version at www rcware eu or report the module ID together with version number of your domat exe to support domat cz NB The default I O module and room unit setting is Address 1 Communication 9600 8 N 1 RcWare SoftPLC Room unit configurator 5 9 UC100 settings Scan the bus and double click the listed controller in the field with scan results The properties window opens 5 1 General settings 5 1 1 Digital inputs 5 1 2 RTC 5 1 3 Settings ioi Digital inputs Settings UC 00 300 Firmware 2 2 Controller settings Senal port settings Temperature Digital Presence mode Symbol control Adress 1 Set temp 15 50 AC New adress Moo xl Set day temp C Baudrate 9600 Set night temp E 14 08 15 Write all to eeprom Set depress temp C wednesday 30 4 2008 W PC Time fa fe fie Wednesday gt i5 50 C Set temp Min temp 30 4 2008 22 23 C Actual temp Mas temp Lore Outside temp Synch
7. and heating water setpoint Symbols Heating Boiler Can be set to 1 2 3 or 4 It may be read by master for further processing in the heating circuit Temperature Humidity Digital Settings Modes Symbol control Humidity Set RH 40 00 z him AH 10 00 a Mas RH 90 00 ca Corr AH 0 00 Dec show places KUCE Dec set places 0 Step 1 1 00 ot Parameters for setting relative humidity setpoint Set RH Humidity setpoint set by user Min RH Max RH Minimum and maximum rH values the user is allowed to set by turning the knob RcWare SoftPLC Room unit configurator 17 6 2 3 Digital 6 2 4 Settings Corr RH Internal correction adds to the measured relative humidity before it is displayed and send to the Modbus table Not relevant now as UIO1x does not contain humidity sensor Dec show places may be 0 1 or 2 number of decimal places to display the actual relative humidity Example 0 45 rH 1 45 2 rH 2 45 25 rH Not relevant here as Ul01x does not contain humidity sensor Dec set places may be 0 1 or 2 number of decimal places to display when changing the relative humidity setpoint Step1 Value to change relative humidity setpoint on one step of the knob The knob has 24 steps to complete one turn Temperature Humidity Digital Settings Modes Symbol control Digital inputs lear latch Latch state Disabled lear latch Latch state Disa
8. ap manual E Might manual Off 1 Others Presence mode Day night mode Fan Heat cool mode The Day night mode is mainly used for residential applications Day auto Day mode set by a time scheduler this is done by master the Ul010 and UI011 do not possess real time clock Symbols Clock Sun Night auto Night mode set by a time scheduler Symbols Clock Moon Day manual Manual override to Day mode or just Day mode if scheduler not present Symbols Sun RcWare SoftPLC Room unit configurator 21 Night manual Manual override to Night mode or just Night mode if scheduler not present Symbols Moon Off Energy savings mode long term unoccupancy 6 2 8 Fan Temperature Humidity Digital Settings Modes Symbol control Disabled Auto A ot A Man 1 eg M Man Man 3 A a MI Others Presence mode Day night mode i P A Healt cool mode For applications where manual fan control is required fancoils split units convectors Fan Auto Fan stages controlled by the master Will probably also display actual fan stage written by master see the Modbus table Symbols Fan A Off Manual off Symbols Fan M Man1 Fan manually on Stage 1 Symbols Fan M Stage1 Man2 Fan manually on Stage 2 Symbols Fan M Stage2 Man3 Fan manually on Stage 3 Symbols Fan M Stage3 6 2 9 Heat cool mode For split units heat pumps etc Off Un
9. bled lear latch Latch state Disabled Digital outputs Offline Ii one i Start action None 7 Offline E one T Start action None r Wi ait tme o Not relevant here as UI010 and UI011 have no digital inputs and outputs The Show mode defines swapping of displayed values There may be up to 5 different values periodically displayed Temperature actual measured temperature incl correction Humidity actual measured humidity incl correction not relevant for UI01x Time real time of the internal clock not relevant for Ul010 UI011 Remote 0 any value sent from the master see below Remote 1 any value sent from the master see below The checked values are periodically changed at the display By pushing the button the unit goes from Show mode to Quick edit mode or Edit mode Show time period to display each of the values selected in Show mode Default 2 secs RcWare SoftPLC Room unit configurator 18 6 2 5 Modes Edit return time Timeout if user inactivity in the Edit mode is longer than the Edit return time the unit automatically goes to Show mode Long push time if the button is pushed for Long push time or longer the unit switches to Edit mode In the Edit mode it is possible to change selected setpoints values and states Quick edit mode by pushing the button shortly less than Long push time the value selected in the Quick edit mode is changed according to
10. brings advanced Modbus addressing functions 1 Start the tool in User mode 2 Check if the modules are connected by scanning the bus 3 Instead of clicking directly to the module address click the Address button 4 Enter a valid module address in the Connect modul Address field 5 Click Connect fl Address editor Adress Word Word Word Bin FE Le ea Sign Sign Connect modul Word MSB LSE Adress ji Disconnect Registers Start 1 Lenght f 0 Status Deci Hex Read ok Time 1000 ms Read ok 8 Read error 0 Write ok 0 D VWerike error Clear count Load from file Save to file Close A table with read values from the controller or room unit opens Here it is possible to read and write firectly to the Modbus registers of the device Please keep in mind that this is an activity which requires advanced knowledge of the register table By improper writing the device may be damaged 1 Click a register row to open a window for writing E SetRegister i a Xx Adress Deci Hex Bin fE E 0000 foooooood 00000000 MSE LSE Get Set and close Close RcWare SoftPLC Room unit configurator 24 7 2 Info 2 Enter a new value in your favorite format 3 Click Set if you want to set the new value and leave the dialog open Click Set and close to set the new value and close the dialog Click Close to cancel the operation In the main program window click the nfo but
11. domat control system Room unit configurator User manual 04 08 1 Contents 7 1 7 2 COMES aiaa SE BRS Sasha ESS SER E Rea Pas ete eae Padi Sasa tata A 2 HIVE gere Kk CTIOIN cece sas Pah is ie a Slt i ah eh ti Dine Daas aaa Raed ies a Be E 3 Hardware configuration mas sch eka teeta Ain i Sees Re oS 3 Mod le detection stance tite ta tate reed reel tatu teat adda dud tate R St ane 3 COMMUNICATION Setting Sasss inae UeukotaanncieeiOnudedadeaieteteunee 4 Scanning the DUS resni A AA A SDS 4 Possible DTODIEMS 52 DU eksl nea inasonaedantayasaatanuedontaiecnadaedstnce 5 WIC TOO SENOS mennar a 6 Gensral Settings srana a aaa aN 6 Tabs with setpoints and parameters ccccceeccsececeeeseeeeeeeseeeseeeeseeeeseeesaees 7 Time Scheele bare e e ra a aa Ei 13 UOT SSiN Sakana hanecaeaacoatench danedeesatoalenat daseteaandereacsonatteen 14 LETS ere eter eee ee en at E E E ee ee ee 14 Tabs with setpoints and parameters cccceccceecceeeceeeeeseeeaeeeseeeseeeseeeeaes 16 Advanced TU CUOINS or ecot saan eens eee tes Sonam aan oes 24 Adde S eae ee oe ae eee eee eee eee SE DE eee Oe ee at ee een SER TE ate Er 24 NO SE ase ae htc dense tees E ele eee Eee LEE ES IEEE DE EGE 25 Any comments questions and improvement suggestions to this manual are welcome at support domat cz Thank you for your feedback www domat cz RcWare SoftPLC Room unit configurator 2 2 Introduction The configuration software domat exe
12. ettings of the unit to a file The settings can be retrieved for download of the same configuration to more units Load Loads settings from a file The loaded settings are written to the device s memory as if they were entered manually For permanent saving click Write all conf to EEPROM 6 2 Tabs with setpoints and parameters At the right of the window there are tabs with advanced controller settings All settings are effective immediately and written to RAM Permanent writing to EEPROM follows by clicking the Write all conf to EEPROM button see above Others 6 2 1 Temperature Temperature Humidity Digital Settings Modes Symbol control Set temp 26 00 fi 2 00 FEE Mire Set day temp 23 00 Max 126 00 Set night temp ham Corr 150 Dec show places i Step 0 50 Dec set places fi Set outside temp fi 5 00 Set DHW temp 55 00 Mir 10 00 bl ax 90 00 Set heating curve fi Set temp Temperature setpoint for writing only Actual temperature setpoint is displayed and continuously updated in the Temp section see above Writing to this variable has the same effect as changing the setpoint by turning the knob Set day temp Setpoint for day mode Set night temp Setpoint for night mode Both those setpoints can be set and read by the master device Dec show places may be 0 1 or 2 number of decimal places to display the actual temperature Example 0 23 C 1 23 2 C 2 23 27
13. he latched state is then kept in the Modbus register until it is read out by the master Latch state Disabled no function Log 0 the input is normally closed log 0 is latched Log 1 the input is normally open log 1 is latched Clear latch Reads out the register and sets the optional latch to its normal state Offline action Requested status of the digital output if the controller is offline no communication from the Modbus master for a definable time Usually None to let the controller do its job even if offline Wait time Time of non communication no datagrams from master to slave which is recognized as communication failure It results in setting the outputs to the Offline action state if defined Entered in seconds 1 to 255 Select from the drop down box or write the value directly If a value larger than 255 is entered the default of 50 seconds is set Start action Requested status of the digital output between power up and the first datagram from master Usually None The Presence mode configuration tab allows to enable and disable various operation modes It is possible to switch between those modes either remotely or in the controller menu after long push or pressing the button shortly short push see the Controller settings tab Quick edit mode Unchecked states are not available for the user However they can be set remotely over Modbus so that the user can switch between RcWare SoftPLC Room unit configurat
14. he valve is closed as there is no need to heat the room now Valve the symbol appears as soon as the valve in the corresponding mode starts to open This is used most and also is the default settings Quick edit mode defines the function of short push of the button None short push has no effect Presence mode short push of the button changes between the modes predefined checked in the Presence mode Allowed operation modes functions and values available in the settings menu after a super long push This is what the user actually can control at the device Temperature correction change of the actual setpoint sets back to 0 with presence mode change If disabled here even turning the knob has no effect Day temp Cooling depress temp Setpoints for heating and cooling for Day Night and Depression mode see the Temperature tab Time real time clock setting hours minutes weekday Actual regulation mode displays the current operation mode Day Night Depression Show mode select values which periodically swap at the display in the Show mode Temperature actual room temperature Outside temp outside temperature must be communicated to the controller by a Modbus master use as an option only Time real time hh mm day of week together with the clock symbol Show time period of swapping the values of Show mode Long push time time to push the button to select the Time schedule menu Super long push
15. here UI011 has no real time clock Set temp Temperature setpoint set by user The setpoint can be changed in the Min Max limits defined in the Temperature tab see below Actual temp Actual measured room temperature inclusive correction Corr defined in the Temperature tab see below Not relevant here UI011 has no humidity sensor Communication parameters In the upper part of the frame there is unit type here UI011 and unit ID each device module controller room unit type has its own ID UI011 201hex Firmware version please report if you experience problems Address Modbus slave address 1 255 of the device New address select or enter the new address here when readdressing the unit Baudrate 1200 19200 bps Com errors Communication error counter Com OK Number of correctly received packets Connected Disconnected Connection status comunication with the unit End Closes the unit window and returns to main program window RcWare SoftPLC Room unit configurator 15 Write all conf to EEPROM writes all the changed values address parameters etc to permanent memory To make new address and baudrate active power off and power on the device again All other parameters are effective immediately NB This button also stores all settings which are in the tabs on the right operation modes setpoints etc lt lt Switches to simplified view no tabs with values Save Saves the actual s
16. ime out o Time out 9 Time out 10 Time out End Scan gt Service code Semis code User mode Possible problems No modules scanned TxD RxD LED at M011 dark Check COM port number and settings Check serial cable must be nullmodem Check if COM port works with other software hardware No modules scanned TxD LED at M011 flashing RxD LED dark Check I O bus cabling and polarity Check if the internal setting of M011 is 9600 8 bit DIPs 1 2 ON 3 4 OFF default setting Check if Modul setting in domat exe is 9600 N One 8 Try to bring the module room unit into INIT mode power off INIT switch to ON power on The slave should respond at 9600 N 8 1 at address 1 Try to communicate with another working module or room unit to see if the converter cabling and software is set properly Another reason may be a non standard type of RS232 RS485 converter Try M011 if not used No modules scanned or communication dropouts TxD RxD LEDs flashing Improperly terminated I O bus check bus termination switches at both ends loose wires in the connectors or EMC disturbances Check the communication with one module only apart from the cabinet and field wiring preferably powered by a separate power source transformer or stabilized power supply eg that supplied with IPCT 1 This may also happen with the most recent notebooks which do not have serial ports over classical
17. ing Cooling Sence of heat cool symbols C Energy f Valve Quick edit mode None Presence mode Allowed operation modes Temperature correction Day temp Night temp Depress temp Cooling day temp Cooling night temp Cooling depress temp Time Presence mode Actual regulation mode f Bay Night Depress Show mode Temperature F Outside temp Time Show time Boo 3 Long push tine is amp Super long push tine 25 E Change ower per po mir P band 30 K const 1200 2 Step minutes 5 min E dit return time jo 5 4 4 lt 1 41 lt 1 41 41 lt 1 4 Change over this signal is usually sent to the controler over the bus according to available media temperature if there is hot water available the controler should be in the Heating mode The default value is Heating and usually there is no need to change this RcWare SoftPLC Room unit configurator 11 Heating sets the controller to Heating mode valve opens if actual setpoint is above measured temperature Cooling sets the controller to Cooling mode valve opens if actual setpoint is below measured temperature Sense of heat cool symbols Energy the heating and cooling symbols display the status of the change over signal which actually means the type of energy which is available for heating or cooling regardless of the actual valve status i e may be that the heating symbol is on hot water in the piping but t
18. it does not matter what time hh mm it is set to Click the Time schedule button in the main window to open the Time schedule window There are predefined events The Edit button at each weekday copies this particular weekday to the Schedule settings frame Then it is possible to modify the events of the day Time for your comfort type 1205 to set 12h 05m No colon necessary Value select from the drop down box Day Night Depression Disabled After all six events are defined click Set schedule to write the schedule to the controller If multiple days are marked ticked prior to pressing the Set schedule button the same schedule is written to all of them In the graphic pan on the left there is the complete weekly list of changes the closer the blue and red setpoint lines are the more comfortable the mode is The graph does not reflect real temperature values it is just a symbolic representation of the operation modes RcWare SoftPLC Room unit configurator 13 6 6 1 6 1 1 Deresan Monday Schedule settings Nagel Preconmdart Daami Dery Goma Edit Sight Precanmiact Degrees Econ 02 00 04 00 0 00 08 00 10 00 12 00 14 00 16 00 18 00 20 00 22 00 Denes Erir Stgt Precanvcnt T uesday Darei Darien ri Edit Migi Pracarikri Der Ecri 02 00 04 00 0600 08 00 10 00 12 00 14 00 16 00 15 00 20 00 22 00 Drege ESorcen Wednesday Saget Precanvort Day Gorton Dakar Edit higi Precari Depe Sco
19. it is off no operation Symbols Off Heat only Heat only mode cooling disabled Symbols Heat Cool only Cool only mode heating disabled Symbols Cool Fan only Brings fresh air in or air circulation without energy heating cooling Symbols Fan Auto Heating or cooling according to actual energy demand both functions enabled Symbols Heat Cool RcWare SoftPLC Room unit configurator 22 Temperature Humidity Digital Settings Modes Symbol control Disabled loft Heat only l Cool only Fan only F Auto i Others Presence mode Day night mode Fan GO Heat cool mode 6 2 10 Symbol control Not relevant here 6 2 11 Remote 0 Defines the way Remote value 0 is displayed and set Step 0 01 Mini 199 99 blas fi 939 99 Show sees 2 Set place 2 Remote Remote Step Value to change setpoint on one step of the knob The knob has 24 steps to complete one turn Min Max Minimum and maximum limits for changing the value by user Show place Number of decimal places to display Set place Number of decimal places to display when setting the value RcWare SoftPLC Room unit configurator See the Modbus table for a detailed overview of values to read wnd write the Remote value 0 by master 6 2 12 Remote 1 Same as Remote 0 but defines the way Remote value 1 is displayed and set 7 Advanced functions 7 1 Address The domat exe tool also
20. ndication below the service code input line There are three modes Light mode It is only possible to scan and adress modules and read data No internal settings are available User mode Most of the functions are available it is possible to change address parameters setpoints and all internal settings Service mode Same as User mode but also possible to bring controllers to default state factory settings and perform analogue input calibration special hardware tool needed If the program is not in User mode check if the data txt file resides in the same folder as domat exe Light mode password empty string User mode password rumcajs Service mode password vecernicek It is recommended to use the User mode for daily work All descriptions and screenshots below are based on User mode 4 1 Communication settings In the Module frame select the serial port of your PC which is connected to the module bus Default communication parameters are 9600 N 1 8 this is also the factory setting of all modules and room units 4 2 Scanning the bus Click the Scan button The address range specified in the Scan frame default 1 to 10 is scanned for present modules All modules found in this range are listed in the window RcWare SoftPLC Room unit configurator 4 4 3 Info Scan Start adress fi End adress fi I 1 Time out 2 Time out 3 MUI0T 4 Time out 5 Time out 6 Time out T
21. or 9 5 2 4 Symbol control Day Night and Auto while a central unit can on top of that set the controller to Depression Central Off Controller settings Serial port settings Temperature Digital Presence mode Symbol control W Day 3E TAT W Night C TET W Depress TT ng ae Party Day Comfort mode Day temperature setpoints apply room occupied Night Reduced mode Night temperature setpoints apply Depress Depression mode the room is unoccupied for a longer time energy savings temperature setpoints apply Auto Temperature setpoints change according to the time scheduler between Day Night and Depress modes Together with the Clock symbol the current mode symbol s is displayed Party Controller goes to Comfort mode for a predefined time of 2 hours Then it goes back to previous mode Not relevant here just to check if the symbols of spanner boiler and alarm bell are displayed properly Those symbols may be switched on and off by the Modbus master and indicate various system statuses and system and maintenance alarms Click the symbol to make it active at the display Click it again to disable it RcWare SoftPLC Room unit configurator 10 Controller settings Serial port settings Temperature Digital Presence mode Symbol control 5 2 5 Controller settings Temperature Digital Presence mode Symbol control Controller settings Serial port settings Change over f Heat
22. r 6 5 1 4 Communication 5 1 5 Others Baudrate for information only can not be changed Write all to EEPROM writes all the changed values address parameters etc to permanent memory To make new address and baudrate active power off and power on the device again All other parameters are effective immediately NB This button also stores all settings which are in the tabs on the right operation modes setpoints etc Communication statistics sent and received telegrams Only relevant for Service mode Actual values Set temp current set temperature PI controller setpoint selected temperature for actual operation and heating cooling mode plus manual setpoint correction Actual temp measured temperature by the internal sensor plus sensor compensation Outside temp outdoor temperature optionally writable over Modbus to the room unit or controller used just for display See Controller settings Show mode PID Output internal value of the room controller output 100 cooling to 100 heating This value is processed in interlocking sequences and PWM modulators before it is sent to the outputs For information and service only Other buttons and information Connected Disconnected Connection status comunication with the unit Close Closes the unit window and returns to main program window lt lt Switches to simplified view no tabs with values Time schedule Opens the weekly scheduler window see
23. r full descrition of the master to UI011 communication see the Room units and controllers Communication protocol description document Scan the bus and double click the listed controller in the field with scan results The properties window opens In the upper bar there is module type and address DI1 DI2 not relevant here UI011 has no digital inputs Push status of the pushbutton Goes green when the pushbutton is pressed Relay 1 Relay 2 not relevant here UI011 has no digital outputs RcWare SoftPLC Room unit configurator 14 6 1 2 RTC 6 1 3 Temp 6 1 4 RH 6 1 5 Settings 6 1 6 Others FE MUTO11 1 l El Digital FR Remoted Remotel 26 00 C Set temp Temperature Humidity Digital Settings Modes Symbol control EE Actual temp Set temp 26 00 i Min 18 00 i RH pri Set day temp 23 00 Max 26 00 i 40 00 Set RH Set night temp 18 00 i Com 150 gt 0 00 Actual RH Dec show places i Dec set places ho Relay 1 po 1 PUSH Push button Relay 2 po 2 Step 0 50 Settings 0 01 00 MUI011 201 Sunday Firmware 5 5 Set outside temp 15 00 3 Mir 020 Date F 02000 Adress 1 Max 30 00 i Set DH temp 55 00 Min 10 00 i Max 50 00 i Set heating curve f New adress f Baudrate 5600 Com eros 52011 70525 M PE Time Synchronize Connected End Write all conf to eeprom Com ok Save Load Not relevant
24. rn 2 00 04 00 06 00 08 00 10000 12 00 14000 16 00 18 00 20 00 22 00 Day Derr Eoorceny SiqniPracontart Thursday Monday DanGantiad Edi Dar Corndort It N praveidheenniat a Tuesday Terese Erir Wednesday 02 00 04 00 0 00 08 00 10 00 12 00 14 00 16 00 18 00 20 00 22 00 Depressi Econ Friday a Thursday Mipi Preni norner i a Frida DiC arnir E dit ly Nighy Precantart Denes Boor C Saturday 02 00 04 00 0 00 0S 00 10 00 12 00 14 00 16 00 15 00 20 00 22 00 Sunday Cresco ari 5 aturday Shgit Precomict Darian Darton Edit SiqniPrecanttart Degrees Gooey Set schedule 02 00 04 00 06 00 0800 10 00 12 00 14 00 16 00 18 00 20 00 22 00 Dees ETEF Sunday Sight Precari i x Day Cornet Write all to eeprom Der erne E dit H gt Precankri Depress Econ Close 02 00 04 00 0 00 08 00 10 00 12 00 14 00 16 00 18 00 20 00 22 00 After you have finished the editing click the Write all to EEPROM button The data is written permanently to the controller s memory The progress bar above the button shows the writing progress in the end of the process there comes a pop up window Writing complete Click Close to close the Time schedule window and return to the main controller window Ul011 settings General Digital The UI011 is a room unit with no control function It only provides actual temperature and user entered data to a master device PLC or any controller and displays operation statuses alarms etc Fo
25. ronize asx PID output Min d n d temp Communication T Set night cool temp 35 00 HE Set day cool temp Set depress cool temp 35 00 E Mat d n d temp 35 00 JE Corr temp 1 50 AE Cor out temp Sie Step temp Connected Close ge Time schedule In the upper bar there is module type and address Oj ml ofl zZz Fo hi a Sh in o ol Sje on Sy ony j ol co ol ofc in ol ml co al a o al la gt gt rq Close initialization DI1 DI2 not relevant here UC100 has no digital inputs Push status of the pushbutton Goes green when the pushbutton is pressed Parameters of the real time clock which control the weekly scheduler Time Day Date current data in the controller PC Time tick if you want to synchronize according to the time of your PC Untick if you want to set a special time e g if the controller is being configured for supplies to another time zone Synchronize writes the PC or given time date and weekday into the controller All changes are immediately active Communication parameters In the upper part of the frame there is unit type here UC100 and unit ID each device module controller room unit type has its own ID UC100 300 hex Firmware version please report if you experience problems Address Modbus slave address 1 255 of the device New address select or enter the new address here when readdressing the unit RcWare SoftPLC Room unit configurato
26. the Modes tab In the main tab Others there are parameters and values which do not require any additional settings such as selection of the enabled states They are RcWare SoftPLC Room unit configurator 19 6 2 6 Presence mode Temperature Humidity Digital Settings Modes Symbol control Temp Enabled al Humidity Disabled Remate Disabled Remote 1 Disabled se Day temp Disabled Start heating temp Enabled Might temp Disabled DH Ww temp Disabled Heating curve Enabled JJ sss aaa FI JAD Others Presence mode Day night mode Fan Healt cool mode Temp Temperature setpoint If disabled it can not be changed even by turning the knob in the Show mode Symbols C F Humidity Relative humidity setpoint Symbols rH Remote 0 Any value read and written by master See the Remote 0 tab Remote 1 Any value read and written by master See the Remote 7 tab Day temp Temperature setpoint for Day mode Symbols Thermometer Sun Start heating temp Outside temperature at which heating mode starts Symbols Thermometer outside the Empty house Night temp Temperature setpoint for Night mode Symbols Thermometer Moon DHW Temp Domestic hot water setpoint Symbols Thermometer Water tap Heating curve Heating curve type 1 4 Symbols Heating Boiler At the screenshot above the modes Temperature setpoint room Start heating at and Heating curve are enabled
27. time time to push the button to select the Settings menu and get access to the settings enabled in Allowed operation modes Change over period time of inactivity after the change over signal comes 1 to 255 mins Intended to let the hydronic system adapt and deliver proper media temperature P band proportional band of the controller control deviation setpoint actual value to open the valve at 100 I const integrating part time to increase the output by the P contribution at constant deviation Step minutes time resolution for time schedule settings Edit return time time to return to the basic display show mode in case of user inactivity RcWare SoftPLC Room unit configurator 12 5 2 6 Serial port settings Baudrate for information only to be changed in the main window see above General setings Settings Parity None Even Odd default is None Stopbits One or Two default is One Temperature Digital Presence mode Symbol control Controller settings eral port settings Baudrate S600 Parity None Stop bits Une 5 3 Time schedule The weekly time schedule in the controller is stored in EEPROM and controls the operation modes according to real time clock and the defined settings Each of the 7 days has 6 events which either can be disabled or set the controller into a particular operation mode Day Night Depression A disabled event does not influence the operation mode and
28. ton In the window there is a list of all the supported modules Check here if the tool is not able to detect your module room unit controller RcWare SoftPLC Room unit configurator 25
29. um temperature that can be set as corrected temperature turning the knob overrides actual setpoint until next operation mode change Max temp Maximum temperature that can be set as corrected temperature Min d n d temp Low limit for setpoint for all modes Day Night Depression Max d n d temp High limit for setpoint for all modes Day Night Depression Corr temp Temperature correction which adds to the measured temperature to compensate external influences Default value is 1 5 C which compensates internal heat losses Corr out temp Optional parameter which adds to the Outside temperature before sending to display Step temp Step for temperature settings when turning the knob RcWare SoftPLC Room unit configurator 5 2 2 Digital 5 2 3 Presence mode Controller settings Serial port settings Temperature Digital Presence mode Symbol control Digital inputs L DI Clear latch Latch state Disabled Clear latch Latch state Disabled gt Clear latch Latch state Logt ool Clear latch Latch state Logt Clear latch Latch state Logt Offline action Relay 1 Relay Off Relay 2 Relay Off walt time 3 0 Start action Relay 1 None Relay Z None Digital inputs Optional latch function is implemented to keep even short signals at digital inputs readable as soon as the signal appears on the input it is written to the Modbus register T
Download Pdf Manuals
Related Search
Related Contents
Samsung LN46B550K1FXZA 45.9" Full HD Black LCD TV PDF版 - 墨田区 C2€: nouveau mode d`emploi E-flite EFL6875 救助隊用化学防護服 - 一般財団法人日本消防設備安全センター Baumatic BTC918GL cooker hood Owner`s Manual Manual del Propietaro Guide de l Samsung Samsung miCoach Käyttöopas 1/3” Tag/Nacht-Domekamera mit IR-Beleuchtung, Fix, VKCD-1325 はじめに 昭和 53 年に水質汚濁が著しい広域的な三閉鎖性海域(東京湾 Copyright © All rights reserved.