Home

USO RESTRITO

image

Contents

1. 12843 Foothill Blvd Suite C Imar California 91342 V 818 898 3380 F 818 898 3360 sales dnfcontrols com Model No 2034CL L PBIO amp 2034CL L T 300 CLIP INSTANT ACCESS SYSTEM Louth Protocol VERSION 3 0 SOFTWARE Note Supports up to 3 Video Server Channels User Manual 1 2034CL L Vs 3 0 300 Clip Instant Access System Louth Protocol PBIO Option 1 Table of Contents REVISION HISTORY GETTING STARTED 8 9 10 SYSTEM DESCRIPTION DEFINITIONS SYSTEM INSTALLATION SHOTBOX B ST300CONTROLLER C PRODUCTION SWITCHER VIDEO SERVER SETUP LOAD A CLIP LEARN A CLIP OR CLIP COMBINATION LEARN ON THE SHOTBOX B LEARN ON THE PRODUCTION SWITCHER C LEARN ON THE ST300 RECALL A RECALLON THE SHOTBOX B RECALL ON THE PRODUCTION SWITCHER C RECALL ON THE ST300 SHOTBOX SHOTKEY MAPPING TO SHOTLIST LOCATIONS PBIO REGISTER MAPPING TO SHOTLIST LOCATION TRIGGER ADVANCED 11 12 2 CREATE A CLIP A SET THE RECORD DURATION B CREATE A NEW C RECORDACLIP CREATING SUBCLIPS A MARKIN OUT POINT B DELETEIN OUT POINT C MANUALLY ENTER IN OUT POINT D CREATE SUBCLIP RECUE THE CURRENTLY LOADED CLIP VIEW THE CLIP ID OF THE CURRENTLY LOADED CLIP VIEW CONTENT OF CUE POINTS ON THE SHOTBOX SHOTBOX CONTROL SWITCHES CLEAR SINGLE CUEPOINT TRANSFERRING CUELISTS TOTRANSMIT CUE POINTS TO THE ST300 B TOTRANSMIT CUE POINTS TO THE PC RECEIVE CUELIST FUNCTION
2. A TORECEIVE CUE POINTS FROM THE ST300 B TO RECEIVE CUE POINTS FROM THE PC 2034CL L Vs 3 0 300 Clip Instant Access System Louth Protocol PBIO Option REFERENCE 20 20 21 22 23 24 25 3 SETUP MENU 20 FUNCTION TABLE 23 SPECIFICATIONS 24 ST300 24 RS422 SERIAL CONNECTOR 24 AUX PORT RS422 SERIAL CONNECTOR 24 GPIIN OUT CONNECTOR 25 ST420 SHOTBOX 25 RS422 SERIAL CONNECTOR 25 POWER CONNECTOR 25 TROUBLESHOOTING 26 A ST420 TROUBLESHOOTING 26 B VERSION3 0HARDWARE OF ST300 ONLY 26 KEY LAYOUT 27 DNF CONTROLS LIMITED WARRANTY 28 Manual 8 eene 1 5 020504 Document ID 2034CL L PBIO User Manual 2034CL L Vs 3 0 300 Clip Instant Access System Louth Protocol PBIO Option 1 REVISION HISTORY 070103 Rev 1 1 Added Section CLEAR SINGLE CUEPOINT and Key Layout Added the following to SETUP MENU CLIP SOM RECALL MODE VIDEO STANDARD 110303 Rev 1 2 Added DNF Controls Limited Warranty Updated Receive Cue List amp Transmit Cue List Function description 120903 Rev 1 3 Added CREATING SUBCLIPS section 012204 Rev 1 4 Changed Key Layout 020504 Rev 1 5 Added note to cover and System Description Supports up to 3 Video Server Channels 4 2034CL L Vs 3 0 300 Clip Instant Access System Louth Protocol PBIO Option Getting Started 2 SYSTEM DESCRIPTION NOW production switchers can load amp play video clips on Grass Valley Group PROFILE
3. ESC at anytime to exit The MENU indicator will turn off MENU MODES Turning Wheel clockwise SET LOUTH Allows user to select Louth Port for each VTR PORT RECORD Press MENU to select the desired record mode Lockout or Crash Full EXTENDED IDs Toggle Extended IDs ON OFF V3 0 Only Extended IDs ON allows access up to 32 characters OFF up to 8 characters CLIP SOM Press displayed softkey to toggle between ZERO and NOT ZERO Select ZERO if the clips that you are using start with 00 00 00 00 Select NOT ZERO if the clips that you are using do not start with 00 00 00 00 RECALL MODE Press Normal or Redirect Redir When one and only one clip is learned into a Cue Point the Clip will be REDIRECTED to load on the currently selected VTR if is on If REDIR is off the Clip will be loaded on the VTR it is LEARNED into VIDEO STANDARD Press displayed softkey to select PAL NTSC not drop frame or DF drop frame WIND MODE Press Softkey to select HOLD Fast wind is maintained only while key is depressed OR LATCH Fast wind is initiated and maintained with momentary key press Select fast wind speed 3 9 to 23 7 by pressing Softkey below SPD 20 2034CL L Vs 3 0 300 Clip Instant Access System Louth Protocol PBIO Option SLOMO ST300 display shows Non T Bar Version SLOMO with SpdRange Press Softkey SPEED to select SLOMO speed ranges Press Softkey
4. 1 Frame Ground 6 Transmit Common 2 Transmit A gt 7 Transmit B gt 3 Receive 8 4 9 Frame Ground 5 5 POWER CONNECTOR 9 Pin D Type Male Pin 1 5v DC 6 No Connection 2 5v DC 7 Ground 3 Ground 8 Ground 4 No Connection 9 Ground 5 No Connection NOTE The GPI connector and OUTPUT 2 are not used with this System 2034CL L Vs 3 0 300 Clip Instant Access System Louth Protocol PBIO 23 TROUBLESHOOTING a ST420 TROUBLESHOOTING 1 keys are RED no communication with 57300 2 keys are dark no communication between ST300 and the Video Server 3 The version of the ST420 must comply in the software version with the ST300 it is connected to To determine the software version of the ST420 do the following a Press SHIFT STOP PLAY The key that displays the current version is RED b The ST420 displays SELECT ST300 V2 1 or V2 0 or V3 0 Press the key for the software version of the ST300 you are using Please refer to the ST300 to determine the version if needed b VERSION 3 0 HARDWARE OF ST300 ONLY VIDEO REFERENCE SETUP Plug the video reference BNC cable into the BNC connector on the back of the ST300 Plug the same video reference into the SYNC IN connector on the rear of the Video Server Press MENU 1 Turn the Wheel until the display says SYNC 2 Press the Softkeys to toggle between SYNC ON and OFF Defaul
5. and other video servers Use the EMEM or SNAPSHOT Learn amp Recall functions of the production switcher to load and play a video clip from a Recall or timeline Use the Run and Trigger functions of the production switcher to Play Stop or Recue the video clip Instantly load a video clip at the press of a button Instantly load a FILL clip amp KEY clip at the press of ONE button then play out both channels in sync The 300 Clip Instant Access System consists of the ST300 SSM VTR Controller STS420 Shotbox and Shotlist Software The ST300 controls up to 3 video channels individually or ganged SHOTLIST provides fast access to existing video clips stored on Grass Valley Group s PROFILE other DDR VDR or Video Server supporting Louth Protocol The SHOTLIST contains up to 300 CLIP IDs stored in non volatile memory in the ST300 Any clip in the SHOTLIST can be quickly loaded by simply entering the associated 3 digit number of its location then pressing LOAD Press PLAY to play the clip Press RECUE to recue to the beginning of the clip or to the recalled time if defined Upon receipt of the Learn command the ST300 saves the CLIP IDs of the currently loaded clips the current time of each clip the VTRs they are loaded on and the current GANG mode into the appropriate Cue Point When the RECALL command is received the ST300 loads the learned Clips onto the learned VTRs cues the Clips to the learned time and restores t
6. configuration of the active VTR s Press LEARN to exit at any time NOTE The LEARN key toggles LEARN mode on off LEARN ON THE PRODUCTION SWITCHER 1 On the ST300 load a clip s on the desired VTR s See LOAD A CLIP Section 5 2 Select and enable the Peripheral Device Addresses for the ST300 3 Do a LEARN to the desired REGISTER The ST300 will save the VTR loaded CLIP ID and current IN time into the REGISTER number in the ST300 LEARN ON THE ST300 1 Select the desired Cue Point by pressing NEXT CUE LAST CUE or by manually entering the Cue Point using the numeric keypad The selected Cue Point number is shown on the bottom line of the display 3 Press SHIFT MARK to initiate the LEARN The display will show Select VTR LEARN Lrn ESC Cancel 4 Press the VTR key desired 1 2 3 5 Press MARK and the ST300 will LEARN save the VTR Number 1 2 3 loaded CLIP ID and current IN time to the selected Cue Point 10 2034CL L Vs 3 0 300 Clip Instant Access System Louth Protocol PBIO Option 7 RECALL a RECALL ON THE SHOTBOX Select the desired Cue Point by pressing the BANK and ShotKey The ST300 will automatically load the Learned clips on the Learned VTRS cue the clips to the Learned time then set the Learned GANG mode b RECALL ON THE PRODUCTION SWITCHER Recall the desired REGISTER NUMBER ST300 will automatically load the Learned clips on the Learned VTRs cue the cl
7. to select 0 gt 200 OR 100 gt 200 NOTE 100 is normal speed Press Softkey BACK to return to SLOMO MENU Press ESC to exit SETUP MENU and save changes OR Turn the Wheel to select another item ST300 display shows T Bar Version SLOMO with WHEEL Press Softkey TBAR or WHEEL to toggle between them The T BAR has a speed range of 0 gt 200 with a detent at 100 play speed OR arange of 0 gt 100 detent at 100 Play speed NOTE 100 is normal speed For Wheel only Press Softkey PRSET to select the SLOMO Preset Speed Mode Press Softkey UPDATE When exiting SLOMO mode the last used speed is saved in the Preset Speed register Press Softkey STATIC The Preset Speed register is NOT updated when exiting SLOMO mode It is only changed by SHIFT SLOMO PRESET SLOMO ST300 SETUP ST300 SETUP Clear Cues SetDefault Press Softkey beneath ClearCues to clear all Cue Points to 00 00 00 00 Press Softkey YES when asked Are You Sure Press Softkey beneath SetDefault to set ST300 to default settings Press Softkey YES when asked Are You Sure DISPLAY The version number for the currently installed software is displayed SOFTWARE VERSION 21 2034CL L Vs 3 0 300 Clip Instant Access System Louth Protocol PBIO Option SYNC ON OFF For V3 0 only Set video sync to ON OFF RECORD Press Softkey to select single button or
8. 2 button record RECORD REC Only OR REC PLAY PBIO ADDRESS Press VTR key to assign PBIO address Display shows PBIO Address 00 Enter 00 23 Enter address number desired on numeric keypad Repeat for all VTRs assigned SWITCHER Select your switcher type GVG Grass Valley Group default or Sony TYPE For Phillips DD35 with PBus use GVG PARITY Select ODD EVEN or NONE This is the parity sent via the Peripheral Bus PBIO to the ST300 PREROLL Enter Preroll value TRANSMIT Transmits Cuelist to another ST300 or to a PC CUELIST RECEIVE Receives Cuelist from another ST300 or a PC CUELIST 22 Option 2034CL L Vs 3 0 300 Clip Instant Access System Louth Protocol PBIO 21 FUNCTION TABLE GOTO SHIFT RECUE Search the VTR to the manually entered time ENTERED TIME Use the ST300 numeric keypad Press ENTER or RECUE NOTE Use 00 00 00 00 to recue a clip to ET 0 if start time is not ET 0 SHIFT VTR 1 Individually press the VTR keys to be included in the gang The OR LED above the key will turn on Press the VTR key again to SHIFT VTR 2 remove from gang the LED above the key will turn off Press OR ESC to exit SHIFT VTR 3 The VTR LEDs that are on show the gang The flashing LED shows which VTR is currently selected FFWD FFWD Press and HOLD to shuttle Release key to stop Set WIND Speed in MENU JOG Select JOG mode and enable Wheel LAST CUE LAST CUE Step to the pre
9. Cue Point 301 309 TRIGGER The operator fires a trigger using the Timeline or Run function on the production switcher The ST300 puts the Video Server into the following modes based on the trigger value GRASS VALLEY GROUP Trigger Value Mode 0 Play 1 Recue to beginning of clip 2 Slo mo using ST300 Preset Speed 3 Reverse Play 4 Still Frame 5 Play 6 Record 7 or greater Play SONY Trigger Value Mode 0 Recue to beginning of clipPlay 1 Play 2 Slo mo using ST300 Preset Speed 3 Reverse Play 4 Still Frame 5 Play 6 Record 7 or greater Play To control more than one VTR enable the Peripheral Device Address for the required VTRs The Trigger will be sent to the enabled devices OR GANG the required VTRs on the ST300 See the Menu Table for GANG instructions Enable the Peripheral Device Address for one of the GANGed VTRs The Trigger will be sent to the enabled VTR The other VTRs in the GANG will perform the same action 2034CL L Vs 3 0 300 Clip Instant Access System Louth Protocol PBIO Advanced 11 13 Option CREATE A CLIP NOTE New clips can be created ONLY if the INPUT Port is selected a SET THE RECORD DURATION 1 Press SHIFT REC 2 The display shows current record duration The second line of the display shows Enter Record Length prompt 3 Enter the desired record duration using the ST300 s numeric keypad 4 Press ENTER to save the new record duration and exit OR Press ESC to exit
10. LOUTH mode the VIDEO SERVER ONLY allows Full Record INSERT and ASSEMBLE record modes are disabled Setup is complete LOAD A CLIP a Select a VTR by pressing VTR 1 VTR 2 or VTR 3 b Press CLIP LIST to view the list of CLIP IDs that are resident on the Video Server The CLIP LIST indicator will turn on c Press LOAD to create and load a new clip Creating a clip is described in CREATE A CLIP Section 11 OR Turn the Wheel to view the existing CLIP IDs on the video server Turn the Wheel clockwise to scroll forward or counter clockwise to scroll backward through the list of available CLIPs Backward scrolling is limited to the last 10 CLIP IDs viewed OR Manually enter a clip ID using the ST300 numeric keypad or Shotbox Qwerty keyboard d Press LOAD to load the selected CLIP ID for playout e Locate the clip to the desired IN time f Repeat steps a e until clips are loaded into the desired VTRs g Set the GANG mode if required 2034CL L Vs 3 0 300 Clip Instant Access System Louth Protocol PBIO Option 6 LEARN A CLIP OR CLIP COMBINATION LEARN ON THE SHOTBOX a C 1 2 3 4 5 Press LEARN the 57420 The LEARN indicator will turn on Select the desired BANK and ShotKey The Learned CLIP ID will be displayed on the pressed key NOTE This will overwrite what you have assigned to the key previously The ST300 will remember the loaded clip s current time and gang
11. ddress is displayed Press VTR 1 VTR 2 VTR 3 to select VTR d Assign a Louth Port address for that VTR 0 9 0 turns that channel OFF e The second line of the display will show Input Enter Out ESC f Press ENTER to select an Input Port A will appear in front of the selected number OR ESC to select an Out Port g Repeat steps c f to assign a Louth Address to ALL VTRs you want to use h Press ESC to leave the MENU mode 4 Check the other options in the SETUP MENU prior to using the ST300 to confirm proper Record mode and other User settable modes 6 2034CL L Vs 3 0 300 Clip Instant Access System Louth Protocol PBIO Option PRODUCTION SWITCHER 1 Connect a standard cable RS422 9 pin serial cable to the supplied turnaround adapter Plug the turnaround adapter into the connector on the rear of the ST300 Connect the other end of the cable to the Peripheral Bus Connector on the production switcher Communication Format 38 4K 8 1 2 To select a Production Switcher type Default 2 Grass Valley Group a Press MENU and turn the Wheel until SWITCHER is displayed b Press Softkeys to toggle between Sony and Grass Valley Press ESC at anytime to exit MENU mode 3 The ST300 has 4 Peripheral Device Addresses one for each VTR that it controls To set the Device Address for each VTR a Press MENU and turn the wheel until Peripheral Address is di
12. e return not being accepted or in a charge for the required repair DNF Controls at its option will repair or replace the defective unit DNF Controls will return the unit prepaid to the customer The method of shipment is at the discretion of DNF Controls principally UPS Ground for shipments within the United States of America Shipments to international customers will be sent via air Should a customer require the product to be returned in a more expeditious manner the return shipment will be billed to their freight account This warranty will be considered null and void if accident misuse abuse improper line voltage fire water lightning or other acts of God damaged the product repair parts are to be supplied by DNF Controls either directly or through its authorized dealer network Similarly any repair work not performed by either DNF Controls or its authorized dealer may void the warranty After the warranty period has expired DNF Controls offers repair services at prices listed in the DNF Controls Price List DNF Controls reserves the right to refuse repair of any unit outside the warranty period that is deemed non repairable DNF Controls shall not be liable for direct indirect incidental consequential or other types of damage resulting from the use of the product SH 28 2034CL L Vs 3 0 300 Clip Instant Access System Louth Protocol PBIO Option
13. equires OpSuite 3 0 software which runs on a Windows based computer Contact DNF Controls for more information a TO RECEIVE CUE POINTS FROM THE ST300 2 3 9 5 6 7 8 Connect connector on the back of 57300 from the VTR4 connector of the transmitting ST300 using RS422 9 pin cable with TX and RX lines crossed A Turnaround Cable Press MENU Scroll the Wheel until Receive CUE List YES Enter Exit ESC is displayed Press ENTER to start receiving The Display shows Waiting to receive on the first line When the Transmitter is ready transfer starts automatically The Display now shows Receiving cuelist After the transfer is over the display shows Done Success Press any key Press any key The display shows Receive cuelist message Press ESC to exit the MENU mode b TO RECEIVE CUE POINTS FROM THE PC 2 Connect the VTR4 connector on the back of the 57300 to the COM ports on the PC using RS422 to RS232 adapter Repeat steps 2 8 of the TO RECEIVE CUE POINTS FROM THE ST300 section 2034CL L Vs 3 0 300 Clip Instant Access System Louth Protocol PBIO Reference 20 SETUP MENU Q Press MENU The MENU indicator will turn on Q Turn the Wheel to select item to change Press MENU OR use the Softkeys to change the desired mode for that option Q Turn the Wheel at anytime to select another item Q Press
14. he learned GANG mode Learn amp Recall may also be done directly from the ST300 DEFINITIONS Throughout this manual VTR DDR VDR amp Video Server will be referred to collectively as Video Server The ST300 S SM is referred to as the ST300 The ST420 5 is referred to as SHOTBOX SHOTKEY refers to the 1 30 switches on the SHOTBOX Words surrounded by brackets for example ENTER are keys on the ST300 or the SHOTBOX XXX XXX means hold the two keys down simultaneously 2034CL L Vs 3 0 300 Clip Instant Access System Louth Protocol PBIO Option 3 SYSTEM INSTALLATION a SHOTBOX 1 Plug one end of a standard 9 pin RS422 serial cable into the OUTPUT connector on the rear of the SHOTBOX Plug the other end of the cable into the AUX connector on the rear of the ST300 2 Connect the 5 VDC 1Amp POWER SUPPLY into the POWER connector on the rear of the SHOTBOX Plug the POWER SUPPLY into an outlet 90 VAC to 240 VAC b 57300 CONTROLLER 1 Plug one end of a 9 conductor RS422 serial cable into the VTR 1 2 3 or 4 connector on the rear of the ST300 Plug the other end of the cable into the 9 pin REMOTE connector on the Video Server 2 Connect the 5 12 12 VDC POWER SUPPLY into the POWER connector on the rear of the ST300 Plug the Power Supply into an outlet 90 VAC to 240 VAC 3 Assign logical Louth ports to ST300 s VTR connectors a Press MENU b Turn the Wheel until VTR Louth A
15. ime using the ST300 s numeric keypad Press ENTER to reload the currently loaded clip at the entered time OR Press ESC to exit without searching 14 VIEW THE CLIP ID OF THE CURRENTLY LOADED CLIP a Press and hold SHIFT then press and release LOAD b The bottom line will show Loaded Clip xxxxxxxx where is the CLIP ID 16 2034CL L Vs 3 0 300 Clip Instant Access System Louth Protocol PBIO Option 15 VIEW CONTENT OF CUE POINTS ON THE SHOTBOX a Press VIEW The VIEW indicator comes on b Press the switch for which you would like to see the content The switch turns RED and the content CLIP ID of the corresponding Cue Point is displayed on a virtual display For Example VTR1 VTR2 VTR3 VTR 4 Clip 23 Clip 13 Clip 77 No Assignment Note the remaining switches are not illuminated d Release the keys to return to normal operation 16 SHOTBOX CONTROL SWITCHES a PLAY Plays out the selected clip b RECUE Returns to the beginning of the clip STOP Stops playout of the clip 17 CLEAR SINGLE CUEPOINT On the Shotbox press SHIFT the Shotkey the content of which you wish to clear The Shotkey becomes blank the corresponding cuepoint is cleared 17 2034CL L Vs 3 0 300 Clip Instant Access System Louth Protocol PBIO Option 18 18 Option TRANSFERRING CUELISTS The TRANSMIT CUELIST function allows you to transmit your list of Cue Point
16. ips to the Learned time then set the Learned GANG mode c RECALL ON THE ST300 1 Select the desired Cue Point by pressing NEXT CUE LAST CUE or by manually entering the Cue Point using the numeric keypad The selected Cue Point number is shown on the bottom line of the display 2 Press LOAD on the ST300 The ST300 will automatically load the Learned clips on the Learned VTRs cue the clips to the Learned time then set the Learned GANG mode 8 SHOTBOX SHOTKEY MAPPING TO SHOTLIST LOCATIONS The SWITCHES on the SHOTBOX access the SHOTLIST locations as follows BANK 0 SWITCHES 1 30 access SHOTLIST locations 001 to 030 BANK 1 SWITCHES 1 30 access SHOTLIST locations 101 to 130 BANK 2 SWITCHES 1 30 access SHOTLIST locations 201 to 230 BANK 3 SWITCHES 1 30 access SHOTLIST locations 301 to 330 BANK 4 SWITCHES 1 50 access SHOTLIST locations 401 to 430 BANK 5 SWITCHES 1 30 access SHOTLIST locations 501 to 530 BANK 6 SWITCHES 1 30 access SHOTLIST locations 601 to 630 BANK 7 SWITCHES 1 30 access SHOTLIST locations 701 to 730 BANK 8 SWITCHES 1 30 access SHOTLIST locations 801 to 830 BANK 9 SWITCHES 1 30 access SHOTLIST locations 901 to 930 11 2034CL L Vs 3 0 300 Clip Instant Access System Louth Protocol PBIO Option 10 12 Option PBIO REGISTER MAPPING TO SHOTLIST LOCATION Register 0 30 gt Cue Point 0 30 Register 31 60 gt Cue Point 101 130 Register 61 90 gt Cue Point 201 230 Register 91 99 gt
17. p recording 14 2034CL L Vs 3 0 300 Clip Instant Access System Louth Protocol PBIO Option 12 CREATING SUBCLIPS a 15 Option MARK IN OUT POINT 1 Press IN OUT key 2 The current Timecode is saved as IN OUT point IN indicator turns on DELETE IN OUT POINT 1 Press DEL key and IN key 2 The IN point is cleared The IN indicator is turned off MANUALLY ENTER IN OUT POINT 1 Press SHIFT and IN key 2 The display prompts to enter new IN point 3 Type in the new timecode using numeric keypad 4 Press ENTER to save the new IN point OR Press ESC to leave without saving OR Press to save the new IN point and recue to it CREATE SUBCLIP 1 Mark or Enter IN and OUT points as described above 2 Press SHIFT CLIP LIST keys 3 The display prompts to enter a subclip name 4 Enter the name using the Shotbox keyboard or the numeric keypad 5 Press ENTER 6 The subclip with the specified name and the IN and OUT points is created 2034CL L Vs 3 0 300 Clip Instant Access System Louth Protocol PBIO 13 RECUE THE CURRENTLY LOADED CLIP a Press RECUE to reload the currently loaded clip to the IN point b Press SHIFT RECUE The display will show xx xx xx xx Where xx xx xx xx Last entered RECUE time Enter RECUE time Enter the t
18. s to a PC using the provided utility software on the PC or to another ST300 Transfer to a PC requires OpSuite 3 0 software which runs on a Windows based computer Contact DNF Controls for more information a TO TRANSMIT CUE POINTS TO THE ST300 1 Connect the VTR4 connector on the rear of the ST300 to the VTR4 connector of the receiving ST300 using an RS422 9 pin cable with TX and RX lines crossed A turnaround cable 2 Press MENU 3 Scroll the Wheel until Transmit CUE List YES Enter ExitZESC is displayed 4 Press ENTER to start transmitting The Display shows Waiting to transmit on the first line 5 When the Receiver is ready transfer starts automatically The Display now shows Transmitting cuelist 6 After the transfer is over the display shows Transfer is over for one second and then shows Waiting to transmit again 7 Connect another ST300 to transmit the list again OR Press ESC twice to exit the MENU mode b TO TRANSMIT CUE POINTS TO THE PC 1 Connect the VTR4 connector on the back of the ST300 to one of the COM ports on the PC using a RS422 to RS232 adapter 2 Repeat steps 2 7 of the TO TRANSMIT CUE POINTS TO THE ST300 section 2034CL L Vs 3 0 300 Clip Instant Access System Louth Protocol PBIO 19 19 Option RECEIVE CUELIST FUNCTION The RECEIVE CUELIST function allows you to receive your list of Cue Points from a PC or from another ST300 Transfer to a PC r
19. splayed b Press VTR 1 VTR 2 VTR 3 or VTR 4 to select a VTR Assign a Peripheral Device Address for that VTR from 0 to 23 by entering the desired address using the numeric keypad OR Press DEL to turn off the device d Select the next VTR and assign a Peripheral Device Address for it e When done press ESC to exit MENU mode 4 Select Parity a Press MENU and turn the Wheel until Parity is displayed b Press Softkey to select ODD EVEN or NONE parity to match the settings on the Production Switcher Press ESC to exit menu mode 5 Configure the production switcher On the production switcher Enable the Peripheral Bus Enable the Peripheral Device Addresses assigned to the ST300 Enable the appropriate Learn Recall levels Enable the Timeline or Recall Trigger function 7 2034CL L Vs 3 0 300 Clip Instant Access System Louth Protocol PBIO Option Turnaround Adapter CONNECTION DIAGRAM 8 GPI 1 OUTPUT2 OUT PUT e e MEE RESET pissed pv sou 87300 55 RESET POWER SUPPLY Installation is complete 2034CL L Vs 3 0 300 Clip Instant Access System Louth Protocol PBIO Option PRODUCTION SWITCHER VIDEO SERVER 9 VIDEO SERVER SETUP Select LOUTH Broadcast communications protocol on the VIDEO SERVER to be controlled If required assign a serial port on the VIDEO SERVER through which the ST300 will control it NOTE In
20. t ON Installing sync into the ST300 and the Video Server and selecting Sync ON will help assure that several channels in the gang will roll in sync For example Fill and Key 26 2034CL L Vs 3 0 300 Clip Instant Access System Louth Protocol PBIO Option KEY LAYOUT 24 EE INT p O 1511 dilo AIH UU 084 9 1 8 OSA 1 13000t 1 193602 STOUELNOO YY Je O ull nsnm NOLVYNIIINOI AIH OOELS 2034CL L Vs 3 0 300 Clip Instant Access System Louth Protocol PBIO 27 Option 25 DNF CONTROLS LIMITED WARRANTY DNF Controls warrants its product to be free from defects in material and workmanship for a period of one 1 year from the date of sale to the original purchaser from DNF Controls In order to enforce the rights under this warranty the customer must first contact DNF s Customer Support Department to afford the opportunity of identifying and fixing the problem without sending the unit in for repair If DNF s Customer Support Department cannot fix the problem the customer will be issued a Returned Merchandise Authorization number RMA The customer will then ship the defective product prepaid to DNF Controls with the RMA number clearly indicated on the customer s shipping document The merchandise is to be shipped to DNF Controls 12843 Foothill Blvd Suite C Sylmar CA 91342 USA Failure to obtain a proper RMA number prior to returning the product may result in th
21. ustable contrast Jog Shuttle Wheel With mechanical detents Optional Slo mo 0 200 of Play Speed 2X Normal Speed RS422 SERIAL CONNECTOR 9 Pin D Type Female VTR1 VTR4 Pin 1 Frame Ground 6 Receive Common 2 Receive A 7 Receive 3 Transmit B gt 8 Transmit A gt 4 Transmit Common 9 Frame Ground 5 Spare POWER CONNECTOR 9 Pin D Type Male Pin 1 5v DC 6 5 VDC 2 5v DC 7 Ground 3 Ground 8 Ground 4 12 VDC 9 Ground 5 12 VDC AUX PORT RS422 SERIAL CONNECTOR 9 Pin D Type Female Pin Frame Ground 6 Transmit Common Receive A 7 Receive Transmit B gt 8 Transmit A gt 9 1 2 3 4 5 Spare 24 Option Receive Common Frame Ground 2034CL L Vs 3 0 300 Clip Instant Access System Louth Protocol PBIO 25 Option IN OUT CONNECTOR 15 Pin D Type Female DB15F Pin 1 GPI OUT 1 9 PLAY 2 GPI OUT 2 10 STOP 3 GPI OUT 3 11 RECUE 4 GPI OUT 4 12 NEXT CUE 5 GPI OUT 5 13 LAST CUE 6 GPI OUT 6 14 RECALL 7 GPI OUT 7 15 GPI 7 IN disabled 8 Ground ST420 SHOTBOX Power 90 VAC to 265 VAC adapter supplied with IEC connector Size L x W x H7 12 x 7 25 x 1 5 front 3 5 rear Weight 5 5 15 Rear Panel Connectors Power DB9M OUTPUT DB9F AUX DBOF Display Six characters on each of three lines on each Shotkey Liquid Crystal Display RS422 SERIAL CONNECTOR 9 Pin D Type Female OUTPUT Pin
22. vious Cue Point Location NEXT CUE NEXT CUE Step to the next Cue Point Location RECORD Places VTR into the Record mode selected by RECORD MODE in the SETUP MENU Press RECORD OR RECORD PLAY REC REWIND RWD Press and HOLD to shuttle Release key to stop Set WIND Speed in MENU SHUTTLE SHUTTLE Select SHUTTLE mode and enable Wheel SLOMO SLOMO Press SLOMO to slo mo the VTR Turn the Wheel or move the T Bar if available to change the play speed Press SLOMO to STILL frame OR Press any transport key to exit SLOMO SLO MO SPEED SHIFT SLOMO For WHEEL ONLY Press SHIFT SLOMO to preset the PRESET slo mo speed Turn the Wheel to select desired speed Press ESC or any transport key to exit STOP STOP Press once to STILL frame VTR Press again to put VTR into STOP mode TIME MODE TIME MODE Press to toggle between ET Elapsed Time and SELECT RT Running Time display modes 23 2034CL L Vs 3 0 300 Clip Instant Access System Louth Protocol PBIO Option 22 SPECIFICATIONS ST300 Power 90 VAC to 265 VAC adapter supplied with IEC connector Size L x W x H 10 1 2 x 6 x 1 1 2 front 3 0 rear T Bar Version L x W x H 12 5 8 x 6 x 1 1 2 front 3 0 rear Weight 4 165 Rear Panel Connectors VTR1 VTR2 VTR3 VTR4 All DB9F GPL e ees DBFI15F DB9M Display Easy to read 2 line back lit LCD display User adj
23. without saving NOTE Set Factory Defaults in the SETUP MENU sets the record duration to hour CREATE A NEW NAME 1 Press CLIP LIST The CLIP LIST indicator turns on The display will show CREATE NEW CLIP 2 Press LOAD The display will show the default CLIP ID 3 Press LOAD to accept the default CLIP ID OR Use NEXT CUE LAST CUE and Wheel to create a CLIP ID Use the NEXT CUE and LAST CUE keys to position the cursor Turn the Wheel to select the desired letter OR Create an ID using the numeric keypad with a maximum of eight characters if extended IDs are OFF and maximum of 20 characters if extended IDs are ON Press ENTER 4 Press LOAD to create the selected CLIP ID If the selected CLIP ID already exists a warning message will be displayed To load the existing clip press ENTER Press ESC to exit without loading the existing clip 2034CL L Vs 3 0 300 Clip Instant Access System Louth Protocol PBIO RECORD A CLIP NOTE To record a clip the video server must have enough memory to record the entire clip Video input must be connected to the Record Channel The ST300 Port selected for recording must be an Input Port a minus number 1 Set the desired record duration as described in Section 11 a SET THE RECORD DURATION 2 Create a new name as described above in Section 11 b CREATE A NEW 3 Press RECORD to start recording 4 Press STOP to sto